7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 1/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3 Page 1 of 18www.harrisstratex.com
Eclipse Software ReleaseNotesVersion 4.3
P/N 260-668060-001 Rev 033. 13th May 2008
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 2/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 2 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Copyright © 2007 by Harris Stratex Networks.
All rights reserved. No part of this publication may be reproduced, transmitted,transcribed, stored in a retrieval system, or translated into any language or computerlanguage, in any form or by any means, electronic, magnetic, optical, chemical, manual orotherwise, without the prior written permission of Harris Stratex Networks.
DISCLAIMER
Harris Stratex Networks makes no representation or warranties with respect to thecontents hereof and specifically disclaims any implied warranties or merchantability orfitness for any particular purpose. Further, Harris Stratex Networks reserves the right torevise this publication and to make changes from time to time in the content hereofwithout obligation of Harris Stratex Networks to notify any person of such revision orchanges.
TECHNICAL SUPPORT
If you require technical assistance or if you have discovered a product issue, pleasecontact the Technical Help Desk nearest to you as soon as possible. Their contactdetails are shown below:
USA
Harris Stratex Networks
120 Rose Orchard Way
San Jose, CA 95134 -1358
Phone: +1 800 227 8332 freewithin US only
Harris Stratex Networks
5727 Farinon Drive
San Antonio, TX 78249
Phone: +1 866 882 5381 freewithin US only
E-mail: [email protected]
Europe, Middle East &Africa
Harris Stratex Networks
4 Bell Drive
Hamilton International TechnologyPark
Blantyre, Scotland, G72 0FB
United Kingdom
Phone : +44 1698 714 073
Harris Stratex Networks
Centrale Parc, Bâtiment 4 Pasteur
Avenue Sully Prud'homme
92298 Châtenay-Malabry CedexFrance
Phone : 33-1-55-52-80-00
E-mail: [email protected]
Asia/Pacific
Harris Stratex Networks
Bldg 10 Unit B, PhilexcelIndustrial Park
Clark Special Economic Zone
Clark Field
Pampanga
Philippines
Phone: +63 45 599 5192
E-mail: [email protected]
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 3/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 3 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Table of Contents
Scope and Purpose .......................................................................................................... 4
Software Introduction........................................................................................................ 4
Supported Functionality.................................................................................................... 5
Configuration................................................................................................................. 5
Diagnostics ................................................................................................................... 7
Protection Support ........................................................................................................ 7
Communications & Networking ..................................................................................... 7
Miscellaneous Features ................................................................................................ 8
Alarms........................................................................................................................... 8
Logs.............................................................................................................................. 8
Security......................................................................................................................... 8
Software Loading .......................................................................................................... 8
Portal Help .................................................................................................................... 9
Compatibility................................................................................................................... 10
Eclipse Hardware Supported....................................................................................... 10
Operating Systems Supported .................................................................................... 13
Computer Hardware Supported .................................................................................. 14
Regional Settings Supported....................................................................................... 14
Network Time Protocol (SNTP) Servers Supported........................................................ 15
Closed Field Issues ........................................................................................................ 15
Closed Significant Issues................................................................................................ 16
Portal and Embedded Compatibility History.................................................................... 16
Important Notes .............................................................................................................. 18
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 4/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 4 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Scope and Purpose
This document provides software release information on supported functionality,compatibility, and known customer affecting issues, relating to the released softwareversions.
The intended users of this document are:
• Harris Stratex Networks Customers
• Harris Stratex Networks Value Added Resellers
• Harris Stratex Networks Value Added Service Providers
• Harris Stratex Networks Product Support staff
• Harris Stratex Networks Field Service staff
Software Introduction
This software has been made available for customer release. In addition to previouslysupported hardware and functionality it now provides additional support for:
The main features included in this release are :
• IDU 300 GE 20x
• 256Mbps 64QAM with E1 waysides
• 312Mbps 128QAM with E1 waysides
• 357Mbps 256QAM with E1 waysides
• 196Mbps 256QAM with DS1 waysides
• 263Mbps 256QAM with DS1 waysides
• 326Mbps 256QAM with DS1 waysides
• 75xE1 16QAM
• 106xE1 64QAM
• 32xDS1 QPSK and 16QAM
• 70xDS1 16QAM, 32QAM and 128QAM
• 84xDS1 64QAM
• 100xDS1 16QAM, 32QAM and 128QAM
• 127xDS1 64QAM
• RAC 30v3 and IDU 300 ES
• 5xE1 16QAM
• RAC 3X
• 64xE1 64QAM
• 100xE1 128QAM
• RAC 40
• 52xE1 32QAM
• RAC 4X
• 2xSTM1 256QAM• IDU 300 ES, IDU 300 GE 20x and DAC ES
• AA throughput improvement
• Ethernet preamble removal
• IDU 300 ES and DAC ES
• MAC table size increased to 2048 entries
• IDU 300 GE 20x and DAC GE
• Portal Dashboard and Status improvements
• Port shutdown diagnostic command
• MAC table access in Portal
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 5/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 5 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
• DAC 4x/16x
• Diagnostic Mode to raise an event on E1 buffer slip
• RAC 40/4X
• Allow mixed ODU 300 EPs & HPs in protected systems
• ODU 300 HP
• Add 195 MHz TR for 8 GHz
• Ethernet configuration now uses Mbps instead of NxE1• User editable Alarm I/O names and severity
• Alarm output activation for any alarm of a specific severity
• Diagnostic mode to output XPD on ODU BNC for polarity alignment
• Customer interface to disable a module prior to removal.
• NMS Broadcast storm resilience
Product Part Number Version Build HSXReference #
Eclipse EmbeddedSoftware
275-250219-040335 4.3 35 1341-113
Eclipse Portal Software 280-200010-0403330 4.3 330 0184-096
This release is supported by ProVision Element Manager System software version 6.1.1with the following exceptions:
• Protected links are not supported in a ring configuration.
• New capacities supported by this release may not be displayed correctly in theProVision reports.
• E1 performance monitoring is not supported.
Supported Functionality
The following headings list functionality that is currently supported by version 4.03embedded and Portal software. Additional functionality (since version 4.02) is highlightedin bold italics.
Configuration
•
Populate information fields such as terminal name, site name, etc• View expected plug-in layout
• Configure frequency, power, modulation and capacity
• Configure tributary interface parameters
• Configure DAC ES ports
• Configure circuits
• Configure IP routing
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 6/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 6 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
• Set radio date and time
• Manage software versions and download
• View active license and download license
• Configure ring protection
• Configure dynamic routing
• View equipment part numbers and serial numbers
• Configure custom T/R splits
• Configure trap destinations
• Configure XP4 compatibility mode
• Configure ring wrap and unwrap criteria
• Configure system function names
• Configure ring unwrap time
• Configuration backup & restore
• RWPR for DAC GE
• Layer 2 link aggregation
• Layer 1 link aggregation with redundancy
• E1/DS1 backplane for DAC GE
• Status forwarding for DAC GE
• DAC GE - Generic L2 Link Aggregation and Enhanced VLAN usability
• E1 performance monitor
• Performance and Monitoring
• View RSL
• View G.826 15-minute and daily registers
• View history graphs and reports
• View real time G.826
• View event log and view event history
• View temperature values
• View forward power data
• View available supply voltages
• Estimated BER (G.821) performance monitor for link history reports
• Save performance data to file
• View Ethernet performance statistics
• View Ethernet performance history
• View combined performance data for 1+1 protected links
• G.826 Performance statistics are available for the offline receiver in a 1+1 link.
• IDU 300 GE 20x Support
• Ethernet configuration now uses Mbps instead of NxE1
• User editable Alarm I/O names and severity
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 7/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 7 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Diagnostics
• Activate tributary/AUX line facing loop back
• Activate tributary/AUX radio facing loop back
• Activate digital loop back
• Activate IF loop back
• Activate circuit loopbacks
• Transmit AIS on individual tributaries
• Enable TX PA mute
• View system summary
• View problem and severity indicators
• Disable ATPC
• Enable DAC PRBS
• Configure safety timers
• View and control ring status
• PRBS tester reset control
• Perform software rollback and reset
• Clear event log
• Troubleshoot Ethernet circuits
• IDU 300 GE 20x and DAC GE
• Portal Dashboard and Status improvements
• Port shutdown diagnostic command
• DAC 4x/16x Diagnostic Mode to raise an event on E1 buffer slip
Protection Support
• Equipment protection supported
• Hitless path protection supported1352
• Unidirectional ring protection supported
• Optical tributary protection supported
• IDU 300 20x v2 Hot Standby Non-Protected Tributary
• IDU 1+1 Protection (only with IDU 300 GE 20X’s)
• IDU Single Ethernet Feed Protection (only with IDU 300 GE 20X’s)
Communications & Networking
• Serial interface supported
• SNMPv2 interface supported
• Ethernet interface support
• NMS overhead channel supported
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 8/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 8 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
• Static routing supported
• OSPF routing supported
• RIP II routing supported
• Configure default gateway
• Discover radios on local LAN
• IDU 300 GE 20x and DAC GE - MAC table access in Portal
Miscellaneous Features
• Manufacturing details supported
• Watch dog supported
• ATPC supported
• Portal auto-version supported (upload Portal from radio)
• Soft reset without interrupting traffic
• As-built report supported
• Data file to send to Stratex Help Desk
• Manage Eclipse via XP4 links
• Launch new Portal session for remote terminal
• Customer interface to disable a module prior to removal
Alarms
• Alarm hierarchy supported
• User configurable alarm thresholds
• Alarm I/O supported
• Alarm output activation for any alarm of a specific severity
Logs
• Event log operational
• Informational event log entries
• Event log notes
Security• Features controlled by license key
• Portal user security
• Auto-login support for ProVision
Software Loading
• Software loading – internal users only
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 9/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 9 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
• Software loading – customer usable
Portal Help
• Customer support details
• About Eclipse Portal
• Eclipse Help integration with alarm troubleshooting entries
• Context sensitive online help
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 10/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 10 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Compatibility
Eclipse Hardware Supported
The following table details the hardware that is supported by this software andcorresponding part numbers.
Hardware Type Part Number Description
IDC EXC-001, EXC-002 Indoor Chassis, 1RU
IDCe EXE-001 Indoor Chassis, 2RU Extended
NCC EXN-001, EXN-002 Node Controller Card
FAN EXF-001, EXF-002 Fan Card
FAN 2RU EXF-101 2RU Fan Card - INUe
INU EXX-000-001, EXX-000-002 Intelligent Node Unit, 1RU
INUe EXX-000-201, EXX-000-202 Intelligent Node Unit, Extended
NPC EXS-001 Node Protection Card
IDU 100 8x EXB-081-001 Indoor Unit, 8xE1, QPSK
IDU 100 16x EXB-161-001 Indoor Unit, 16xE1, QPSK
IDU 100 20x EXB-201-001 Indoor Unit, 20xE1, Hot Standby
IDU 300 8x EXG-081-001 Indoor Unit, 8xE1/DS1
IDU 300 20x EXG-201-001 Indoor Unit, 20xE1/DS1, HotStandby
IDU 300 20x v2 EXG-231-001 Indoor Unit, 20xE1/DS1, HotStandby, version 2
IDU 300 ES EXG-211-001 Indoor Unit, Fast Ethernet +
8xE1/DS1
IDU 300 SP 4x EXG-041-001 Indoor Unit, 4xE1, QPSK
IDU 300 SP 16x EXG-161-001 Indoor Unit, 16xE1, QPSK, HotStandby
IDU 300 155o EXG-999-001 Indoor Unit, 1xSTM-1/OC3, HotStandby
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 11/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 11 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
HardwareType
Part Number Description
ODU 100 ECS-07-0154-* ECS-07-0161-* ECS-07-0196-*
ECS-07-0245-* ECS-08-0119-* ECS-08-0126-*
ECS-08-0151-* ECS-08-0266-*ECS-08-0311-*
ECS-08-0305-* ECS-11-0490-* ECS-11-0500-*
ECS-11-0530-* ECS-13-0266-* ECS-15-0315-*
Frequency bands supportedare:
7, 8, 11, 13, 15, 18, 23, 26, 31,32, 38 GHz
Note: the software supports
AUX EXA-001 Auxiliary and alarm I/O card
DAC 4x EXD-040-001 Data Access Card, 4xE1/DS1
DAC 16x EXD-160-001 Data Access Card, 16xE1/DS1
DAC 155o EXD-152-001 Data Access Card, 1xSTM-1/OC3, Optical
DAC 155oM EXD-153-001, EXD-156-001 Data Access Card, 1xSTM-1/OC3Multiplexed to 63E1/84DS1,Optical
DAC ES EXD-171-001 Data Access Card, 10/100baseTFast Ethernet
DAC GE EXD-180-001 Data Access Card, GigabitEthernet
DAC 2x155e EXD-254-001 Data Access Card, 2xSTM-1/OC3, Electrical
DAC 3xE3/DS3 EXD-330-001 Data Access Card, 3xE3/DS3,tributary protection
DAC 3xE3/DS3M EXD-331-001 Data Access Card,3xE3/DS3,tributary protection,2xE3 Mux ports for framed E3 toE1 Bus or transparent E3(34Mbps pipe) to 17E1
RAC 10 EXR-011-001 Radio Access Card, ODU 100
RAC 10 v2 EXR-011-002 Radio Access Card, ODU 100,
version 2
RAC 30 EXR-999-001, EXR-999-002 Radio Access Card, ODU 300
RAC 30 v3 EXR-999-003 Radio Access Card, ODU 300,version 3
RAC 40 EXR-966-001 Radio Access Card, ODU 300
RAC 3X EXR-900-001 Radio Access Card, ODU 300
RAC 4X EXR-906-001 Radio Access Card, ODU 300
IDU 300 GE 20x EXG-261-001 Indoor Unit, GE Gigabit Ethernet+20xE1/DS1 Protectable
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 12/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 12 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
ECS-15-0420-* ECS-15-0490-* ECS-15-0644-*
ECS-15-0728-* ECS-18-0340-* ECS-18-1010-*
ECS-18-1092-* ECS-23-0600-* ECS-23-1008-*
ECS-23-1200-* ECS-23-1232-* ECS-26-1008-*
ECS-31-0225-* ECS-31-0410-* ECS-31-0450-*
ECS-31-0490-* ECS-31-1008-* ECS-31-1975-*
ECS-32-0812-* ECS-38-1260-*
these frequency bands/splitshowever the hardware optionmay not exist.
* All numbers supported
ODU 300EP
EDH-05-0300-* EDH-05-0312-* EDH-06-0160-*
EDH-06-0170-* EDH-06-0252-* EDH-06-0340-*
EDH-07-0154-* EDH-07-0161-* EDH-07-0168-*
EDH-07-0196-* EDH-07-0245-* EDH-08-0119-*
EDH-08-0126-* EDH-08-0151-* EDH-08-0208-*
EDH-08-0266-* EDH-08-0305-* EDH-08-0310-*
EDH-08-0311-* EDH-10-0065-* EDH-10-0091-*
EDH-10-0143-* EDH-10-0230-* EDH-10-0350-*
EDS-11-0490-* EDS-11-0500-* EDS-11-0530-*
EDH-13-0266-* EDH-15-0315-* EDH-15-0420-*
EDH-15-0475-* EDH-15-0490-* EDH-15-0644-*
EDH-15-0728-* EDH-18-0340-* EDH-18-1008-*
EDH-18-1010-* EDH-18-1092-* EDH-18-1120-*
EDH-18-1560-* EDH-23-0600-* EDH-23-1008-*
EDH-23-1200-* EDH-23-1232-* EDH-26-0800-*
EDH-26-0855-* EDH-26-1008-* EDH-28-0450-*
EDH-28-1008-* EDH-31-0225-* EDH-31-1975-*
EDH-32-0812-* EDH-38-0700-* EDH-38-1000-*
EDH-38-1260-*
Frequency bands supportedare:
5, 6, 7, 8, 10, 11, 13, 15, 18,23, 26, 28, 31, 32, 38 GHz
Note: the software supportsthese frequency bands/splitshowever the hardware optionmay not exist.
* All numbers supported
ODU 300SP
EQS-07-0154-* EQS-07-0161-* EQS-07-0168-*
EQS-07-0196-* EQS-07-0245-* EQS-08-0119-*
EQS-08-0126-* EQS-08-0151-* EQS-08-0208-*
EQS-08-0266-* EQS-08-0305-* EQS-08-0310-*
EQS-08-0311-* EQS-11-0490-* EQS-11-0500-*
EQS-11-0530-* EQS-13-0266-* EQS-15-0315-*
EQS-15-0420-* EQS-15-0475-* EQS-15-0490-*
EQS-15-0644-* EQS-15-0728-* EQS-18-0340-*
EQS-18-1008-* EQS-18-1010-* EQS-18-1092-*
EQS-18-1120-* EQS-18-1560-* EQS-23-0600-*
EQS-23-1008-* EQS-23-1200-* EQS-23-1232-*
EQS-26-0800-* EQS-26-0855-* EQS-26-1008-*
EQS-28-0450-* EQS-28-1008-* EQS-31-0225-*
EQS-31-1975-* EQS-32-0812-* EQS-38-0700-*
EQS-38-1000-* EQS-38-1260-* EFS-07-0154-*
EFS-07-0161-* EFS-07-0168-* EFS-07-0196-*
EFS-07-0245-* EFS-13-0266-* EFS-15-0315-*
EFS-15-0420-* EFS-15-0490-* EFS-15-0644-*
EFS-15-0728-* EFS-18-0340-* EFS-18-1120-*EFS-18-1560-* EFS-23-0600-* EFS-23-1008-*
EFS-23-1232-* EFS-38-1260-*
Frequency bands supportedare:
7, 8,11, 13, 15, 18, 23, 26, 28,31, 32, 38 GHz
Note: the software supportsthese frequency bands/splitshowever the hardware optionmay not exist.
* All numbers supported
ODU 300HP
EAH-06-0252-* EAH-06-0160-* EAH-06-0170-*
EAH-06-0340-* EAH-07-0154-* EAH-07-0161-*
EAH-07-0168-* EAH-07-0196-* EAH-07-0245-*
EAH-08-0119-* EAH-08-0126-* EAH-08-0152-*
EAH-08-0195-* EAH-08-0208-* EAH-08-0266-*
EAH-08-0306-*
EAH-08-0310-* EAH-08-0311-* EAH-11-0490-*
Frequency bands supportedare:
6, 7, 8, 11, 13, 15, 18, 23, 26,28, 31, 32, 38 GHz
Note: the software supportsthese frequency bands/splits
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 13/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 13 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
EAH-11-0500-* EAH-11-0530-* EAH-13-0266-*
EAH-15-0315-* EAH-15-0420-* EAH-15-0475-*
EAH-15-0490-* EAH-15-0644-* EAH-15-0728-*
EAH-18-0340-* EAH-18-1008-* EAH-18-1010-*
EAH-18-1092-* EAH-18-1120-* EAH-18-1560-*
EAH-23-0600-* EAH-23-1008-* EAH-23-1200-*
EAH-23-1232-* EAH-26-0800-* EAH-26-1008-*
EAH-28-0450-* EAH-28-0900-* EAH-28-1008-*
EAH-31-0225-* EAH-31-1900-* EAH-31-1975-*
EAH-31-2050-* EAH-32-0812* EAH-38-0700-*
EAH-38-1000-* EAH-38-1260*
however the hardware optionmay not exist.
* All numbers supported
Operating Systems Supported
The following table details the supported Operating Systems.
Operating
System
Notes
HP-UX 11i v1 -
Windows XP Pro(SP1, SP2)
Refer to Eclipse User Manual for XP support information
Windows 2000Pro (SP3)
-
Windows NT 4.0 -
Windows 98 -
Windows Vista New Portal Installer with Microsoft Vista Support
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 14/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 14 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Computer Hardware Supported
The following table details the minimum hardware specifications required to operatePortal.
Attributes Minimum Specifications
Processor P3,500 MHz
RAM 256 MB
HD space (install andoperate)
80 MB
Monitor adaptor SVGA
Monitor display resolution 800 x 600
Monitor colours 256
Mouse Yes
Note: ATI video cards installed with a ‘Catalyst driver’ set earlier than 4.9 will cause thePortal performance page to stop working if the screen-saver activates. The workaroundis to install the latest video drivers from the video card manufacturer.
Regional Settings Supported
Portal supports the following locales and there are no known limitations:
Albanian, Belarusian, Bulgarian, Catalan, Croatian, Czech, Danish, Dutch, English,Estonian, Finnish, French, German, Greek, Hebrew, Hungarian, Icelandic, Italian,Japanese, Korean, Latvian, Lithuanian, Macedonian, Norwegian, Polish, Portuguese,Romanian, Russian, Serbian, Serbo-Croatian, Slovak, Slovenian, Spanish, Ukrainian.
The following table details known regional settings limitations.
Locales Known Limitations
Arabic The calendar does not display the day of the week correctly
Chinese The date format is not consistent in event browser, the calendar doesnot display the day of the week correctly, and the alarms page is largerthan 800 x 600 resolution
Hindi The alarms page is larger than 800 x 600 resolution
Swedish Commas are displayed instead of decimal points when entering theTR/RX spacing and TX/RX frequency. Portal will accept commas whenthe user enters TX/RX frequency, however it will not accept commas for
the TX/RX spacing.The workaround is to use decimal points.
Thai Alarms page is larger than 800 x 600 resolution
Turkish Some event log entries in the event browser and link history pages maynot be displayed
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 15/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 15 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Network Time Protocol (SNTP) ServersSupported
Eclipse software has been successfully tested with the following SNTP time servers.
• NetTime
Closed Field Issues
The following table lists field issues that have been fixed since the 4.1.16 release.
TroubleTicket #
Issue Description
9465 ODU 300 EP : Latch PA current alarm when ODU is muted, alarm is now
still monitored.8023 ODU 500: 38 GHz Synthesizer core power level has been adjusted to a
value that give stable operation at high temperatures.
6492 RAC 4X : XPIC was not recovering after some maintenance activities ,now fixed.
5376 DAC E3/DS3 MUX : Intermittent sync losses can be experienced whenused with DAC 155oM. This irregularity has been resolved.
4513 IDU SP 16x/4x : If the reset button is pressed for longer than 10seconds, it leaves the radio terminal in a condition where it is expecting aconfiguration change, a timeout set so that if no change is made the IDUreverts to its original condition.
4795 IDU 300ES / DAC-ES : Performance Data not being logged correctly forthese modules, problem now resolved.
5449 DHCP function will now assign the Terminals IP address as desired.
3361 DAC ES & IDU 300 ES : A lower throughput rate was observed if an AAtest pattern was fed through these radios. Although not a fault , the fullthroughput is now observed if this test pattern is used.
3350 IDU 300 ES : Unable to stop flow control while switch ports are in auto-negotiation, problem now resolved.
2851 ODU 300 SP 1+1 : Reports fwd power of -50dB when muted, nowreports -100 dB as standard.
1037 RSSI Fluctuations observed when ATPC is enabled at low power levels,this problem has been resolved.
826 INUe: Heavy Ethernet Port NMS traffic could cause soft resets, thisproblem has been resolved.
618 A short burst of AIS generated when a node in a Ring Network wrapsaffected some 3
rd party equipment, this undesirable feature no longer
exists.
1551 NPC : NPC alarms have a warning severity level.The severity of the -48V alarm has been changed from warning to major.
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 16/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 16 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
Closed Significant Issues
The following table lists significant issues that were discovered duringdevelopment/testing since the version 4.1.16 release. These issues have been fixed bythis release.
Software Type Issue Description
Embedded IDU 300 ES : Throughput can drop when connected to DAC GE/IDU300 GE. The IDU ES had a problem at 40E1 capacity that has nowbeen resolved.
Embedded IDU 300 GE 20x & DAC GE : 64b frame throughput is low (~8%), withpreamble not removed. When both ends of a data link include thisversion of software (or later), then they will remove preamble fromEthernet packets, improving throughput particularly with small frames
Embedded IDU 300 GE 20x : Duplicate Ethernet packets can be Rx'd onprotection switch .An automatic Tx protection switch can result in~50ms of duplicated received Ethernet packets as the active Ethernetswitch moves from one IDU to the other.
EmbeddedNo Circuits shown for IDU ES and IDU GE in the As-built report
Configured circuits are now shown in the As-built report
Embedded RAC 4X : ATPC not operating for 2xSTM-1/128QAM and93E1/256QAM
ATPC is now operational for these capacities.
Embedded RAC 4X : Power settings are not automatically refreshed whencapacity is changed.
Portal now shows the correct maximum power after capacities havebeen changed.
Embedded ODU 300 HP : Add support for v2 Calibration files
The ODU 300 HP now supports v2 calibration files, as well as theoriginal v1 calibration files.
Embedded RAC 3X ,106E1 ports 101-106.Use of radio ports 101-106 has been disabled in an INU – they are ofno practical use as the TDM backplane is limited to 100 circuits
Embedded ODU 300 EP & ODU 300 HP : Latch PA current alarm when ODU ismuted.The PA current alarm could not be evaluated when the ODU is muted.Now the alarm is latched to the state it was in prior to muting. Thislatched value is stored in non-volatile memory in the ODU.
Portal and Embedded Compatibility History
Embedded Software Version Matching Portal Software Version
2.1.18 and later (Portal auto-versionsupported)
2.1.1, Build 2112 and later
2.0.44 2.0.1, Build 2018
1.0.29 1.0.1, Build 1923
0.10.31 0.10.1, Build 1660
0.10.20 0.10.1, Build 1660 or 1722
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 17/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 17 of 18Copyright © 2008 Harris Stratex Networks, all rights reserved.
White PaperRelease Notes
0.9.32 0.9.2, Build 1358
7/24/2019 Eclipse Software Release Notes 4.3
http://slidepdf.com/reader/full/eclipse-software-release-notes-43 18/18
5/13/2008 1352-087 - Eclipse Software Customer Release Notes 4 3.3 Page 18 of 18Copyright © 2008 Harris Stratex Networks all rights reserved
White PaperRelease Notes
Important Notes
1. Traffic may be affected when upgrading software between two specific versionsof software. Contact a Harris Stratex Networks Technical Help Desk for details,contact details are on page ii of these release notes.
2. When upgrading software ensure the remote end of a link is upgraded before thelocal end. This is particularly important where the RAC 40 is involved.
3. Portal Help integration requires Stratex Help revision 014 or higher. Stratex Helpis a standalone help program that is installed separately to Portal, it can be foundon the Eclipse Setup installation CD.
4. A license upgrade requires a power cycle if the backplane type changes.
5. A power cycle or a RAC reinsertion is required if a capacity change exceeds thelicense capacity size.
6. To reduce the traffic outage time during a software load of an IDU 100 1+1protected radio the following steps should be observed:
a. Lock all units to TX/RX on the Primary and load only to the high bandSecondary IDU/ODU pair
b. Keeping all units TX/RX locked on the Primary, load only to the lowband Secondary IDU/ODU pair
c. Switch all units to TX/RX on the Secondary and lock them there
d. Keeping all units TX/RX locked on the Secondary, load only to the highband Primary IDU/ODU pair
e. Keeping all units TX/RX locked on the Secondary, load only to the lowband Primary IDU/ODU pair
f. Switch all units back to TX/RX auto
7. Care should be taken not to run OSPF and Static routing within the same internalOSPF routing domain.
8. If Portal loses communication with an IDU 300 SP radio when changing the IPaddress, restart Portal to restore communication.
9. Disable any PC firewalls before performing a software download.
Harris Stratex Networks encourages its customers to report problems so we can resolvethem as quickly as possible.