4
Effect of Extreme Environmental Thermal Cycling On COTS MEMS Pressure Sensor Rajeshuni Ramesham, Ph.D. Jet Propulsion Laboratory Abstract: Motorola’s Commercial-Off-The-Shelf (COTS) manifold absolute pressure (MAP, 7 – 110 kPa) sensors were subjected to extreme environmental thermal cycling, beyond the manufacturer's specifications of -40 o C to +135 o C, to study how robust the package is. The extreme environmental thermal cycling conditions are as follows: Total number of cumulative thermal cycles: 23 Temperature range: -125 o C to 90 o C Ramp rate: 7 o C/minute Dwell time: 10 minutes A non-destructive x-ray evaluation technique has been used to image the sensors before and after 15 and 23 thermal cycles. There were no failures observed after 15 thermal cycles. However, our observation shows that sixty seven percent (67%) of the pressure sensors failed due to the opening of wire bonds from 15 to 23 thermal cycles. Introduction: This pressure sensor has been chosen since it is fabricated using microelectromechanical fabrication technology and the conventional electronic packaging technology. There is no particular mission or project associated with this sensor. Per the manufacturer’s specifications this sensor can only be used in engine control systems with a temperature range of -40 o C to +135 o C. The feature of the pressure sensors: The specified operating temperature range of the manifold absolute pressure sensors is –40 o C to +135 o C. The operating characteristics of the sensor are V out Range 0.1 mV min to 4.9 V max . The operating pressure range is 7 kPascals to 110 kPascals. Figure 1 (a and b) show the top and bottom view of the pressure sensor. The manifold absolute pressure sensor is based on a two-chip design with a signal conditioning integrated circuit, which is trimmed to provide the desired calibration. The output is an analog voltage and to Manifold Absolute Pressure. The purpose of these sensors is for engine control systems. Thermal Cycling Tests: A thermal cycling chamber was used to assess how robust the pressure was in a temperature range of –125 o C to +90 o C. This chamber has the capability Figure 1: Optical photographs of Motorola’s pressure sensor (a) top view and (b) bottom view. A B
Transcript
Page 1: Effect of Extreme Environmental Thermal Cycling …Effect of Extreme Environmental Thermal Cycling On COTS MEMS Pressure Sensor Rajeshuni Ramesham, Ph.D. Jet Propulsion Laboratory

Effect of Extreme Environmental Thermal CyclingOn COTS MEMS Pressure Sensor

Rajeshuni Ramesham, Ph.D.Jet Propulsion Laboratory

Abstract: Motorola’s Commercial-Off-The-Shelf (COTS) manifold absolute pressure(MAP, 7 – 110 kPa) sensors were subjected to extreme environmental thermal cycling,beyond the manufacturer's specifications of -40oC to +135oC, to study how robust thepackage is. The extreme environmental thermal cycling conditions are as follows:

� Total number of cumulative thermal cycles: 23� Temperature range: -125oC to 90oC� Ramp rate: 7oC/minute� Dwell time: 10 minutes

A non-destructive x-ray evaluation technique has been used to image the sensors beforeand after 15 and 23 thermal cycles. There were no failures observed after 15 thermalcycles. However, our observation shows that sixty seven percent (67%) of the pressuresensors failed due to the opening of wire bonds from 15 to 23 thermal cycles.

Introduction: This pressure sensor has been chosen since it is fabricated usingmicroelectromechanical fabrication technology and the conventional electronicpackaging technology. There is no particular mission or project associated with thissensor. Per the manufacturer’s specifications this sensor can only be used in enginecontrol systems with a temperature range of -40oC to +135oC.

The feature of the pressure sensors: The specified operating temperature range of themanifold absolute pressure sensors is –40oC to +135oC. The operating characteristics ofthe sensor are Vout Range 0.1 mV min to 4.9 Vmax. The operating pressure range is 7kPascals to 110 kPascals. Figure 1 (a and b) show the top and bottom view of thepressure sensor. The manifold absolute pressure sensor is based on a two-chip designwith a signal conditioning integrated circuit, which is trimmed to provide the desiredcalibration. The output is an analog voltage and to Manifold Absolute Pressure. Thepurpose of these sensors is for engine control systems.

Thermal Cycling Tests: A thermal cycling chamber was used to assess how robust thepressure was in a temperature range of –125oC to +90oC. This chamber has the capability

Figure 1: Optical photographs ofMotorola’s pressure sensor (a) topview and (b) bottom view.

A B

Page 2: Effect of Extreme Environmental Thermal Cycling …Effect of Extreme Environmental Thermal Cycling On COTS MEMS Pressure Sensor Rajeshuni Ramesham, Ph.D. Jet Propulsion Laboratory

to perform thermal cycling in a temperature range of –196oC to +200oC. After opticalinspection (Figure 1) of the six pressure sensors they were loaded into the chamber forthermal cycling. We prevented condensation by bringing the hardware to a warmtemperature before opening the chamber. Figure 2 shows x-ray imaging of the pressuresensor and the wirebonds in the sensor regime performed at 15 thermal cycles from -125oC to +90oC, shown in the thermal profile provided by Figure 3.

Figure 4 shows the x-ray imaging of the sensor after 15 thermal cycles. There were nofailures observed in the sensor or wirebond integrity. We then performed 8 more thermalcycles. As a result of the additional cycling, several of the wirebonds in pressure sensornumber 2 were open. This can be seen vividly in the x-ray image of Figure 5. Thisindicates that the pressure sensors do fail after 15 thermal cycles, however, we do notknow where between the 15th and 23rd cycles the failure took place. We have alsoconfirmed similiar failures with sensors 3, 4, and 6 as shown in the x-ray image of Figure6.

A B

Figure2: X-ray imaging ofMotorola's (a) complete pressuresensor and (b) wirebonds in thesensor region where there is a bulkmicromachined silicon membrane(sensor 2). This is before thermalcycling.

Ramp rate:7oC/min

-125oC10 minutesof Dwell time

+85oC10 minutesof Dwell time

45oC

Cycle 1 Cycle 2 Cycle 3

RoomTemperature

Figure 3: Thermal cycle profile employed for thermal cycling.

Page 3: Effect of Extreme Environmental Thermal Cycling …Effect of Extreme Environmental Thermal Cycling On COTS MEMS Pressure Sensor Rajeshuni Ramesham, Ph.D. Jet Propulsion Laboratory

A B Figure 4: X-ray imaging of Motorola's(a) complete pressure sensor and (b)wirebonds in the sensor region wherethere is a bulk micromachined siliconmembrane, after 15 extreme thermalcycles were performed between -125�Cto +90�C (sensor 2). The dwell time is10 minutes and the ramp rate is7�C/minutes.

Sensor 2 Sensor 2

Sensor 2 Sensor 2

A

B

C D

Figure 5: X-ray imaging of the Motorola's (a) complete pressure sensor and (b) wirebonds in the sensorregion where there is a bulk micromachined silicon membrane, after 23 extreme thermal cycles performedbetween -125�C to +90�C (sensor 2). The dwell time is 10 minutes and the ramp rate is 7�C/minute.

Page 4: Effect of Extreme Environmental Thermal Cycling …Effect of Extreme Environmental Thermal Cycling On COTS MEMS Pressure Sensor Rajeshuni Ramesham, Ph.D. Jet Propulsion Laboratory

Summary: Motorola’s manifold pressure sensors were subjected to extreme temperaturethermal cycling –125oC to +90oC. X-ray images of the pressure sensors where takenbefore and after 15 and 23 thermal cycles. There was no opening of the wirebonds orfailures observed after 15 thermal cycles, however, several wirebonds were open after 23thermal cycles. Therefore, these COTS pressure sensors were not reliable in the extremetemperature range employed in this test.

Acknowledgements: Thanks are due to Mr. Steve Bolin for his timely help in x-rayimaging prior to and after thermal cycling of the pressure sensors. I would like to thankDr. Reza Ghaffarian for his encouragement and support. This work is supported byNEPP to assess the reliability of this package.

Sensor 3 Sensor 3

Sensor 4 Sensor 6

A B

C D

Figure 6: X-ray imaging of the Motorola's (a) complete pressure sensor and (b) wirebonds in thesensor region where there is a bulk micromachined silicon membrane, after 23 extreme thermalcycles performed between -125�C to +90�C (sensor 3, 4 and 6). The dwell time is 10 minutes andthe ramp rate is 7�C/minutes.


Recommended