Benoy 03.10.09
Benoy
Effective design, Management and Use of Buildings Designing against Fire BS 9999 Fire Safety
November 2009
BSI Conference
Benoy 03.10.09 Designing against Fire
BS 9999 – Designers systems in place • Education and currency
• Design process
• Verification process and Audits
Benoy 03.10.09 Designing against Fire BS 9999
Education and Currency • Regular CPD with Fire Consultants
• Dissemination of information
Benoy 03.10.09 Designing against Fire BS 9999
Education and Currency • Maintaining currency and dissemination
• Maintaining technical library and information
• Information and knowledge retrieval
Benoy 03.10.09 Designing against Fire BS 9999
Design process • Requirements
• Building type, project nature, location
• Which regulations apply?
• Designers’ compliance
• Implementing BS 9999
Benoy 03.10.09 Designing against Fire BS 9999
Requirements • Laws, Regulations and Standards
• Regulatory Reform (Fire safety) Order Act
• Approved Document Part B
• Fire Design Standards BS 9999
• Issuing Fire Strategy documentation to users
• Users to maintain and update Fire Strategy
HMSO: Fire Safety Risk Assessment
Benoy 03.10.09 Designing against Fire BS 9999
Designers compliance • BS 9999
• Risk
• Implementing Fire Strategy in design
• Documentation
• Review - QDR
Benoy 03.10.09
Designers compliance • Apply Fire strategy report/ QDR
• Risk of fire – Concept risk profile BS 9999 Table 5
• Resisting fire
• Stopping smoke
• Evacuation
Designing against Fire BS 9999
Microsoft free image
Benoy 03.10.09 Designing against Fire BS 9999
Designers compliance • Passive Design Considerations
• Design layouts
• Fire resistance/Fire stopping
• Fire safety signage
• Coordination of active fire services
Benoy 03.10.09 Designing against Fire BS 9999
Designers compliance • Produce fire protection package
• Check Third Party requirements, e.g.
Insurers – Property preservation
• Audit check – Test certificates
Benoy 03.10.09 Designing against Fire BS 9999
Fire strategy report/QDR Process
• Fire consultant
• Qualitative Design Review (QDR)
• Fire strategy content • Fire risk
• Reference to relevant
Parts of BS 9999
Approved Document Part B
Benoy 03.10.09 Designing against Fire BS 9999
Verification Process • Test Certificates – Standardized details
• Non Standardized details
• Audit checks - WREN
Benoy 03.10.09 Designing against Fire BS 9999
Verification • Fire Tests and Classifications
• British and EU standards
• Accreditation schemes, e.g. Agrément certificates
• CE Marks (Product labelling)
BERR: BIS
Benoy 03.10.09 Designing against Fire BS 9999
Test Certificates – Standardised details • Relevant to nature and condition of application
contained by tests or certification
• Must pass the relevant performance
Required and Specified
• Revised details must be signed off
Benoy 03.10.09 Designing against Fire BS 9999
Bespoke details and innovative products • Details must be approved by
• Fire Officer/District Surveyor,
• Manufacturer and Installers (warranty).
Benoy 03.10.09 Designing against Fire BS 9999
Bespoke details and innovative products • Desk Study
• Destructive testing is not possible
• Refurbishments, e.g.
Grade Listed properties
• Historical data • Use only if it is comparable and
accepted by Fire Officer/District Surveyor
Benoy 03.10.09 Designing against Fire BS 9999
Summary • Physics and mechanics of fire design unchanged
• BS 9999 formalisation of design process
• New inclusions and allowances
Benoy 03.10.09
Benoy
Thank you Presented by Hsi Sung Thomas BSc(Hons) Dip Arch ARB