+ All Categories
Home > Documents > Efficient 100G Transport - truecom.com › wp-content › uploads › 2017 › 05 ›...

Efficient 100G Transport - truecom.com › wp-content › uploads › 2017 › 05 ›...

Date post: 07-Feb-2021
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
2
FSP 3000 Modules Efficient 100G Transport When Versatility Matters Most Telecom service providers and enterprises have made it clear – they need 100G transport technology in their networks in order to handle increased data traffic and bandwidth consumption. While the industry has moved quickly with the development of 100G, speed isn’t everything. Spectral efficiency, price, space and power dissipation metrics also have to be improved over today’s 10G and 40G offerings. Our FSP 3000 100G modules are the most efficient and secure way to transport your data in all applications. Highest Flexibility at Lowest Cost We recognize that there is no one-size-fits-all in optical transport. Enterprise, access, metro and long- haul networks all have different requirements. Our FSP 3000 therefore offers both a transponder and a G.709-compliant multiplexer variant, enabling you to transport a variety of protocols transparently and with the lowest latency. Ethernet, Fibre Channel, InfiniBand and SONET/SDH can all be transported efficiently and cost-effectively. Our 100G modules are equipped with client and network pluggable interfaces. In accordance with the network requirements, you can choose between direct and coherent detection. Direct detection is optimized for enterprise and data center applications that typically consist of point-to-point networks bridging distances up to 200km. Coherent detection is optimized for long haul, new backbone and overlay networks, where reach, fiber impairment tolerance and network flexibility are the key. Key Benefits Lowest cost-per-bit transport available today Compact design for industry-leading space efficiency Low power consumption and minimum heat dissipation Wide selection of LAN, SAN and SONET/SDH client protocols Ultra-low latency for high-performance data mirroring ADVA ConnectGuard™ network encryption Pluggable client and network interfaces – coherent and direct detection Network Module Client 100GbE OTU-4 CFP G.709 framing OTN-, Eth-PM GCC0/1/2 GFEC ODU-4 SR10, LR4 100G coherent, 4x 28G DWDM (96ch C-band) Grey (LR4) CFP OTU-4 OTN PM adjust. FEC 100G Muxponder (10TCE-PCN-16GU+100G) 100G Transponder (WCC-PCN-100G) Module Client Module Network OTU-4 config. EFEC OTN PM SFP+ SFP+ SFP+ SFP+ SFP+ SFP+ SFP+ SFP+ SFP+ SFP+ 10x 10GbE (WAN/LAN) 10x 8G FC 8x 10G FC 7x 16G FC 10x STM-64/OC-192 10x 5G IB CFP GMP ODUflex ODU-4 or 100G coherent, 4x 28G DWDM (96ch C-band) Grey (0.3/10km) CWDM (8ch+4ch), DWDM (40ch C-band) Grey (SR10, LR10R, LR4)
Transcript
  • FSP 3000 Modules

    Efficient 100G Transport

    When Versatility Matters Most

    Telecom service providers and enterprises have made it clear – they need 100G transport technology in their networks in order to handle increased data traffi c and bandwidth consumption. While the industry has moved quickly with the development of 100G, speed isn’t everything. Spectral effi ciency, price, space and power dissipation metrics also have to be improved over today’s 10G and 40G offerings. Our FSP 3000 100G modules are the most effi cient and secure way to transport your data in all applications.

    Highest Flexibility at Lowest Cost

    We recognize that there is no one-size-fi ts-all in optical transport. Enterprise, access, metro and long-haul networks all have different requirements. Our FSP 3000 therefore offers both a transponder and a G.709-compliant multiplexer variant, enabling you to transport a variety of protocols transparently and with the lowest latency. Ethernet, Fibre Channel, Infi niBand and SONET/SDH can all be transported effi ciently and cost-effectively.

    Our 100G modules are equipped with client and network pluggable interfaces. In accordance with the network requirements, you can choose between direct and coherent detection. Direct detection is optimized for enterprise and data center applications that typically consist of point-to-point networks bridging distances up to 200km. Coherent detection is optimized for long haul, new backbone and overlay networks, where reach, fi ber impairment tolerance and network fl exibility are the key.

    Key Benefi ts

    • Lowest cost-per-bit transport available today

    • Compact design for industry-leading space effi ciency

    • Low power consumption and minimum heat dissipation

    • Wide selection of LAN, SAN and SONET/SDH client protocols

    • Ultra-low latency for high-performance data mirroring

    • ADVA ConnectGuard™ network encryption

    • Pluggable client and network interfaces – coherent and direct detection

    © 2015 ADVA Optical Networking. All rights reserved. Confidential.1

    Block diagrams for the new 100G datasheet

    NetworkModuleClient

    100GbEOTU-4CFP

    G.709 framing OTN-, Eth-PM

    GCC0/1/2

    GFEC

    ODU-4

    SR10, LR4

    100G coherent,4x 28G DWDM (96ch C-band)

    Grey (LR4)

    CFPOTU-4

    OTN PM

    adjust. FEC

    100G Muxponder (10TCE-PCN-16GU+100G)

    100G Transponder (WCC-PCN-100G)

    ModuleClient Module Network

    OTU-4

    config. EFEC

    OTN PMSFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+SFP+

    10x 10GbE (WAN/LAN)10x 8G FC8x 10G FC7x 16G FC10x STM-64/OC-19210x 5G IB

    CFP

    GM

    PO

    DU

    flex

    ODU-4or

    100G coherent, 4x 28G DWDM (96ch C-band)

    Grey (0.3/10km)CWDM (8ch+4ch), DWDM (40ch C-band)

    Grey (SR10, LR10R, LR4)

  • For more information please contact an ADVA Optical Networking consultant or visit us at www.advaoptical.com

    Fact Sheet, version 07 / 2015

    Scaling and Securing Data Center and IXP Connectivity

    Data centers and Internet exchange points are experiencing an exponential increase in the amount of network traffic that they have to sustain due to cloud computing and emerging web applications. One of the most challenging issues in the design and deployment of a data center is power and space consumption. The energy consumption of the data center infrastructure and the Internet network topology mainly define the overall energy efficiency.

    Our 100G modules provide industry-leading 100G density in a compact footprint with low power consumption and deliver wire-speed throughput at ultra-low latency. They are designed to respond instantly and efficiently to changing network conditions, ensuring mission-critical information is always available and always secure. Their flexible client architecture enables a seamless migration path from 10G up to 100G without hardware exchange.

    With more and more data in the cloud, security is becoming vital. You need to ensure that your data is secure and intact. That’s why we offer the most robust in-flight encryption available. In fact, we are the first in the industry to offer 100Gbit/s with built-in AES-256 encryption technology. We encrypt at the lowest network layer for 100% throughput regardless of packet size and our solution is completely protocol agnostic.

    Reliable and secure data transport at the lowest possible cost per bit makes our 100G modules ideal for high-capacity LAN and SAN private-line services. They are the perfect solution for facilitating virtualization between data centers, business continuity and disaster recovery operations as well as cloud networking and Internet exchange applications.

    Item Name Muxponder 10TCE-PCN-16GU+ (AES) 100G Transponder WCC-PCN-100G

    System Requirements FSP 3000 release 11.2 or later FSP 3000 release 13.3 or later

    Client Formats 10GbE LAN/WAN, 40GbE and 100GbE, 5G IB, 8G FC, 16G FC, OC-192/STM-64

    100GbE, OTU-4

    Line Interface Direct detection (4x25G) CFPCoherent detection (1x100G) CFP

    Direct detection (4x25G) CFPCoherent detection (1x100G) CFP

    Protection 50ms line protection 50ms line protection

    Wavelength Range C-Band (50GHz) C-Band (50GHz)

    Mapping Process Mapping into G.709 OTU-4 Mapping into G.709 OTU-4

    Performance Monitoring Physical Layer, EFEC, G.709 OTN Physical Layer, EFEC, G.709 OTN

    Power Consumption 100W 100W

    Environmental Characteristics +5°C … +40°C, 5% ... 85% relative humidity

    +5°C … +40°C, 5% ... 85% relative humidity

    Physical Dimensions 2 slots (W) x 5 height units (H) 2 slots (W) x 5 height units (H)

    Product specifications are subject to change without notice or obligation.


Recommended