4
Index
Index Pages
Smart Home Complete Solutions 7
Products 9
The New ABS Floor Drain 3000 20
Floor / Bathroom Drains 22
Basic Information 25
HT-Discharge Pipes and Fitting (PPs) 26
Important Instructions for Laying 27
PP Range of High - Temperature Discharge Pipes with inlaid lip seal 28
Chemical Resistance 30
Technical Requisites and Drugs 36
Pharmaceuticals and cosmetics 38
Foodstuffs and Luxury Items 40
Chapter 1
Chapter 2
5
Notes
6
7
10
Notes
11
12
13
Above Ground
Pipes with SocketDn I d1 S1 D t Kg/m
52099903 50 750 50 1.8 64 58 0.29742030001 1500 50 1.8 64 58 0.29732020001 3000 50 1.8 64 58 0.29742020001 75 1000 75 1.9 89 61 0.84832020002 3000 75 1.9 89 61 0.84842020002 110 1000 110 2.7 128 72 1.00832020003 3000 110 2.7 128 72 1.00832020004 160 6000 160 4 174 85 1.932020004 160 3000 160 4 174 85 1.9
Bend 45 °
Bend 87.5 °
Dn α Z1 Z2 h Kg50 45° 12 15 74.5 0.04975 45° 17 20 83.0 0.084110 45° 25 28 101.0 0.160
Dn α Z1 Z2 h Kg50 87.5° 27 31 89.5 0.05075 87.5° 39 43 105.0 0.093
110 87.5° 57 61 133.0 0.230
5201
5202
1
14
Above Ground
Branch 45 °
Branch 87.5 °
Dn α Z1 Z2 Z3 Kg50/50 45° 130.0 61 61 0.09275/50 45° 134.0 79 74 0.11575/75 45° 168.0 91 91 0.115110/50 45° 148.0 104 91 0.220110/75 45° 175.0 116 109 0.265
110/110 45° 266.0 133 133 0.375
Dn α Z1 Z2 Z3 Kg50/50 87.5° 114.9 29 29 0.08075/50 87.5° 118.0 42 30 0.11575/75 87.5° 142.0 43 43 0.142110/50 87.5° 122.0 59 30 0.205110/75 87.5° 152.0 60 44 0.235110/110 87.5° 185.0 61 61 0.310
5204
5205
Bend with inspection accessDn α Z1 Z2 h Kg75 87.5° 43 36 96 0.158
110 87.5° 57 61 133.0 0.262
5203
Bend with inner threadDn d1 Z1 Z2 L Kg
50/1.5” 50.1 23 23 84 0.05
52020
15
Above Ground
Double Branch 45 °
Double Branch 87.5 °
Dn α Z1 Z2 Z3 L Kg75/75/75 45° 28 59 59 153 0.190
110/75/75 45° 2 118 109 177 0.41110/110/110 45° 40 85 85 201 0.530
Dn α Z1 Z2 Z3 L Kg75/75/75 87.5° 36 44 44 140 0.197
110/75/75 87.5° 35 62 46 152 0.355110/110/110 87.5° 53 64 64 187 0.363
5207
5207
Branch with inspection accessDn α Z1 Z2 Z3 L Kg
75/75 87.5° 36 44 44 140 0.216110/50 87.5° 27 59 30 122.0 0.337110/75 87.5° 35 62 64 186 0.417
110/110 87.5° 57 61 61 185.0 0.383
5206
Double socketDn h I Kg50 112 2.2 0.04175 118 2.2 0.070
110 140 2.6 0.170
52080
16
Above Ground
Inspection Pipes
52090
Dn I Kg50 115 0.07575 142 0.145110 185 0.330
PlugDn h Kg50 39 0.01375 39 0.034
110 46 0.066
52091
Eccentric ReducerDn d1 z1 L Kg
50/32 50.1 14 68 0.04350/1” 50.1 14 68 0.04350/40 50 11 66 0.03375/50 75 20 78 0.054
110/50 110 39 105 0.115110/75 110 25 91 0.122 52092
17
Siphon
Socket with inner thread
Vent
52099
52093
52080
Double Socket 160 mmDn L L1 S Kg160 184 90 4 0.390
Dn d1 L H α Kg110/110 110.1 202 155.4 45° 0.633
Dn d1 L L1 Kg50/1.5” 50.1 100 85 0.038
Dn H L S Kg50 32 75 2.4 0.02975 40 103 2.6 0.069110 50 143 3 0.148
52080
Above Ground
18
Above Ground
Bend 160 mm 87.5 °
Dn d1 L L1 S α Kg160 160 189 90 4 87.5° 0.610
52020
1
Dn L L1 S Kg110 200 137 3.3 0.274160 200 123 4.9 0.566
Eccentric Reducer 110 / 160 mm
Dn d1 L L1 S Kg160/110 160.1 215 90 4 0.380
52092
Bend 160 mm 45 °
Dn d1 L L1 S α Kg160 160 229 90 4 45° 0.605
52010
Repairing Socket
1
1
52080
19
Above Ground
Branch 160 mm 45 °Dn d1 L L1 S α Kg
160/110 160 366 100 4 45° 0.755160/160 160 437 100 4 45° 1.100
52040
Branch 160 mm 87.5 °Dn d1 L L1 S α Kg
160/110 160 320 100 4 87.5° 0.640160/160 160 370 100 4 87.5° 0.805
52050
1
1
20
Double Socket 160 mm
Eccentric Reducer 110 / 160 mm
Dn L L1 S Kg160 194 100 5 0.550
Dn d1 L L1 S Kg160/110 160 225 100 5 0.475
52080
52092
Under Ground
1
Pipes with SocketDn I d1 S1 D t Kg/m
52099903 50 750 50 1.8 64 58 0.29742030001 1500 50 1.8 64 58 0.29732020001 3000 50 1.8 64 58 0.29742020001 75 1000 75 1.9 89 61 0.84832020002 3000 75 1.9 89 61 0.84842020002 110 1000 110 2.7 128 72 1.00832020003 3000 110 2.7 128 72 1.00832020004 160 6000 160 4 174 85 1.932020004 160 3000 160 4 174 85 1.9
21
Bend 160 mm 45 °
Branch 160 mm 45 °
Branch 160 mm 87.5 °
Bend 160 mm 87.5 °
Dn d1 L L1 S α Kg160 160 236 100 5 45° 0.710
Dn d1 L L1 S α Kg160/110 160 366 100 5 45° 1.100160/160 160 437 100 5 45° 1.525
Dn d1 L L1 S α Kg160/110 160 320 100 5 87.5° 0.900160/160 160 370 100 5 87.5° 1.210
Dn d1 L L1 S α Kg160 160 189 100 5 87.5° 0.865
52040
52050
52010
52020
Under Ground
1
1
22
The New ABS Floor Drain 3000
23
Available Option
24
Floor / Bathroom Drains
25
Floor / Bathroom Drains
Dimension - Measurements - weight
26
Dimension - Measurements - weight
27
28
HT-Discharge Pipes and Fitting (PPs)
29
Important Instructions for Laying
30
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
31
Keywords
32
PP Range of High-TemperatureDischarge Pipes with inlaid lip sealPP Range of High-TemperatureDischarge Pipes with inlaid lip seal
33
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
34
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
35
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
36
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
37
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
38
Technical Requisites and Drugs
39
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
40
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
41
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
42
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
43
PP Range of High-TemperatureDischarge Pipes with inlaid lip seal
44
Notes
45
Notes