Series ZYY3000(Solenoid valve: SY3000)
Series ZYX3000(Solenoid valve: SX3000)
Series ZYY/ZYXEjector Valve Unit
Nozzle diameter: ø0.7, ø1.0Type S: Standard type L: Large flow type
Ejectors and solenoid valves can be mounted on the same manifold.Centralized wiring of ejector
(ZYX3000: Individual pressure switch not included)
1055
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
How to Order Ejector Valves for ZYY3000
Without light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressorWith surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)
NilSZRU
Light/Surge voltage suppressor
NPN open collector 1 output,without analog output, 3 turn setting
NPN open collector 1 output,without analog output, 200 degree setting
NPN open collector 2 outputs,without analog output, 3 turn setting
NPN open collector 2 outputs,without analog output, 200 degree setting
NPN open collector 1 output,with analog output, 3 turn setting
NPN open collector 1 output,with analog output, 200 degree setting
PNP open collector 1 output,without analog output, 200 degree setting
14
15
16
17
18
19
55
Output specifications(Vacuum pressure switch)
10Y3ZY
Rated voltage
Y3SeriesSY3000
56VSR
24 VDC12 VDC6 VDC5 VDC3 VDC
Wiring specifications(Vacuum pressure switch)
S 15
GHL
LNLOM
MNMO
Electrical entry
Lead wire length 300 mmLead wire length 600 mmWith lead wires (Length 300 mm)Without lead wires Without connectorWith lead wires (Length 300 mm)Without lead wires Without connector
Grommet
L plugconnector
M plugconnector
Nozzle diameter
Manual override
NoneWith vacuum pressure switch
NilE
Vacuum pressure switch
With manifold blockNone
NilMN
Manifold block
Connector box typeLOU
Lead wire/Voltage suppressor specifications
NoneWith silencer
Nil1
Silencer
–84 kPa–53 kPa
SL
0.71.0
0710
Non-locking push typePush-turn locking slotted typePush-turn locking lever type
NilDE
Max. vacuum pressure
L Z5 LOU
For electrical entry types G, H, L, M
1234
100 VAC200 VAC
110 VAC [115VAC]220 VAC [230VAC]
DC specifications
AC specifications (50/60 Hz)
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC
NilLC
CLCN
Lead wire length 0.6 mLead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
Grommettype
Connectortype
Note) The connector box type and serial transmission type are only available with 5 (24 VDC).
Types LN and MN are equipped with sockets (2 pcs.).Not compatible with the FU electrical entry which is used on Series SY3000 plug-in type manifolds (45F, 45P, 45T, 45T1, 45S, 45S1, 45S2, 45S3).
Note 1)
Note 2)
Types R and U are DC only.Since surge voltage is prevented with a rectifier in the case of AC, there is no type “S”.
Note 1)Note 2)
Ejector Valve Unit
Series ZYY/ZYX
1056
M
Without light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressor
NilSZ
Light/Surge voltage suppressor
NPN open collector 1 output,without analog output, 3 turn setting
NPN open collector 1 output,without analog output, 200 degree setting
NPN open collector 2 outputs,without analog output, 3 turn setting
NPN open collector 2 outputs,without analog output, 200 degree setting
NPN open collector 1 output,with analog output, 3 turn setting
NPN open collector 1 output,with analog output, 200 degree setting
PNP open collector 1 output,with analog output, 200 degree setting
14
15
16
17
18
19
55
Output specifications(Vacuum pressure switch)
10X3ZY
Rated voltage
X3Series SX3000
NilN
Common specificationsPositive commonNegative common
56VSR
24 VDC12 VDC6 VDC5 VDC3 VDC
Wiring specifications(Vacuum pressure switch)
S 15
GHL
LNLOM
MNMO
Electrical entryLead wire length 300 mmLead wire length 600 mmWith lead wires (Length 300 mm)Without lead wiresWithout connectorWith lead wires (Length 300 mm)Without lead wires Without connector
Grommet
L plugconnector
M plugconnector
Nozzle diameter
Manual override
NoneWith silencer
NilE
Vacuum pressure switch
Plug-in typeNon plug-in type
NilF
Plug-in/Non plug-in type
With manifold blockNone
NilMN
Manifold block
NoneWith vacuum pressure switch
Nil1
Silencer
–84 kPa–53 kPa
SL
0.71.0
0710
Non-locking push typePush-turn locking slotted type
NilD
Max. vacuum pressure
5 M Z
For electrical entry types G, H, L, M
DC specifications
NilLC
CLCN
Lead wire length 0.6 mLead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
Grommettype
Connectortype
Plug-in typeSerial transmission type
LOZ
Lead wire/Voltage suppressor specifications
How to Order Ejector Valves for ZYX3000
LOZ
Note 1) The serial transmis-sion type is 5 (24 VDC) only.
Note 2) V, S and R specifica-tions are 45T, 45T1.
Note 1) The symbol is “Nil” for the single grommet type and when not equipped with light/surge voltage suppressor.
Note 2) Match with the common specification of the manifold.
Note) For types LN and MN, the single solenoid has 2 sockets and the double solenoid has 3 sockets.
Ejector Valve Unit Series ZYY/ZYX
1057
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
For solenoid valve and ejector valve combination
For ejector valves only(Without solenoid valves: individual wiring type is compliant only.)
Y 3X 3SS5 45
Y 3X 3ZZY
Change to ZZYEjector valvenumbers
45 J 1 U
With ejector
Number of ejectors1 to 10
Ejector mounting position
JZZY 1 U
With ejector
Number of ejectors1 to 10
Example) ZYY-J3U
∗ ZYY35MZ-10S1-E15C∗ ZYY35MZ-10S1
2SETS1SET
1SET
[Example: When individual wiring type model 45 for SY3000 is selected]
ZZY Y3-45-04D-C6-SY3000 manifold model Ejector valve
numbers
J1U 1SET
∗ SX3000-75-1A∗ SY3140-5LZ∗ SY3240-5LZ∗ ZYY35LZ-10S-E15C
1SET1SET1SET1SET
UD
U sideD side
Note 1)
However, (optional DIN rail) is a special order specification.
SY3000/SX3000Same as ordering manifold.
Enter the following together with the manifold number:
1. Part no. of solenoid for SY3000/SX30002. Part no. of ejector valve for ZYY3000/ZYX3000.
∗ is the symbol for a built-in assembly. Add the ∗ symbol at the beginning of part numbers for solenoid valves, etc. to be mounted, and enter these together in order from the D side.
∗ When ordering manifold valve components individually without adding the ∗ symbol, add -MN at the end of the ejector valve numbers.
Note 1) Varies according to the total number of solenoid valve and ejector valve stations. Refer to pages 1074 to 1095 for the Manifold Valve Specifica-tion Sheet.
Series ZYY/ZYX
How to Order Manifold Valves for ZYY3000/ZYX3000 (Split Base/DIN Rail Mounting)
Ejector valveZYY35LZ-10S-E15C-MN
Double solenoid (24 VDC)SY3240-5LZ
Single solenoid (24 VDC)SY3140-5LZ
Blanking plate assemblySX3000-75-1A
Cylinder port sizeC6 : With ø6 One-touch fittingManifold base (4 stations)ZZYY3-45-04D-C6-J1U
U side
Stations····3 2 1
D side
1058
Series ZYY3000
Series ZYX3000
Ejector Valve Specifications
Supply/Release Valve Specifications
ZY3–07S
0.7 1.0
0.6 MPa
0.45 MPa
5 to 50°C
ZY3–07L ZY3–10S ZY3–10L
11
–84
18
–53
22
–84
32
–53
Valve type
Type of actuation
Fluid
Operating pressure range
Ambient and fluid temperature
Allowable voltage fluctuation
Electrical entry
Power consumption
Effective area (Cv factor)
Pilot type 3 position 3 port solenoid valve
Closed center
Air
0.2 to 0.6 MPa
5 to 50°C
–10 to +10%
Grommet : G, H L plug connector: L, LN, LO
M plug connector: M, MN, MO
0.5 W (With indicator light: 0.6 W): Series ZYY3000
0.6 W (With indicator light: 0.65 W): Series ZYX3000
4.68 mm2 (0.26)
Ejector valve model
Nozzle diameter (mm)
Max. suction flow rate N (L/min (ANR))
Max. vacuum pressure (kPa)
Maximum operating pressure
Standard supply pressure
Operating temperature range
Series SY3000/SX3000 in manifold/split base combinations DIN rail mount type can be mounted
Compact (integrated construction of ejector and valve)Copper-free and fluorine-free measures implemented
Ejector Valve Unit Series ZYY/ZYX
1059
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
Sensor type
Set pressure range
Hysteresis
Repeatability
Temperature characteristics
Operating voltage
ZSE1– 00 –14–X129 (–X130)
ZSE1– 00 –15–X129 (–X130)
ZSE1– 00 –16–X129 (–X130)
ZSE1– 00 –17–X129 (–X130)
ZSE1– 00 –18–X129 (–X130)
ZSE1– 00 –19–X129 (–X130)
ZSE1– 00 –55–X129 (–X130)
Diffusion type semiconductor pressure sensor
0 to –101 kPa
±1% full span or less
±3% full span or less
12 to 24 VDC (Ripple ±10% or less)
PNP opencollector
Max. 80 mANPN open collector 30 V Max. 80 mA
Lights up when ON (Red) Lights up when ON (Red)Lights up when ON
(OUT1: Red, OUT2: Green)
None
1 point
3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees 200 degrees
1 point2 point
None1 to 5 V
1 to –10% of set pressure (Adjustable)
17 mA or less (When 24 VDC is ON) 25 mA or less (When 24 VDC is ON)
0.2 MPa
17 mA or less (When 24 VDC is ON)
1 to –10% of set pressure (Adjustable)3% full span or less (Fixed)
Model
ON-OFF output
Operationindicator light
Setting trimmerrotation angle
Analog output
Setting points
Current consumption
Max. operating pressure
Electronic Vacuum Pressure Switch Specifications
Note 1) When using an ejector, there is no problem if pressure of 0.5 MPa is applied for 1 second or less.Note 2) X129 is for Series ZYX3000 and X130 is for Series ZYY3000.Note 3) For details about wiring, refer to the Operation Manual that can be downloaded from SMC website (http://www.smcworld.com).
Series ZYY/ZYX
1060
How to Set the Pressure How to Use the Connector1. Attaching and detaching connectors
Hysteresis
ZSE1--14/-15/-18/-19
ZSE1--16/-172. Crimping of lead wire and socket
Connector
Lead wire
Socket
Hook
+21–
• When using to confirm adsorption, set to the minimum vacuum pressure at which adsorption is possible. If set below this valve, the switch will turn ON even when adsorption has failed or is insufficient. Also take note that if the setting is too high, the switch may not turn ON even with good adsorption.
Strip 3.2 to 3.7 mm at the end of the wire, place the exposed core wire into the socket properly and crimp with a crimping tool. When this is done, be sure that the lead wire covering does not get into the core wire crimping area. (Crimping tool: Model DXT170-75-1)
• AttachingInsert the sockets into the square holes of the connector (with +, 1, 2, – indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.
• DetachingTo detach a socket from a connector, pull out the lead wire while pressing the socket’s hook with a stick having a thin tip (about 1 mm). If the socket will be used again, first spread the hook outward.
• To install the connector, hold the lever and connector unit between your fingers and insert it straight onto the pins. Then lock it by pressing the pawl of the lever into the slot on the housing.
• To remove the connector, pull it straight out while pressing the lever down with your thumb to release the pawl from the slot.
Hysteresis is the difference between the pressure at which the output signal turns ON and the pressure at which it turns OFF. It turns ON at the set pressure.
• The ON pressure is set with the pressure setting trimmer. High vacuum settings are obtained by turning it clockwise.
• When setting, use a flat head screw driver which fits the slot in the trimmer, and turn it gently with your finger tips.
• Hysteresis can be set using the hysteresis setting trimmer. The setting is increased by turning it clockwise, and the range is 1 to 10% of the ON pressure.
• When the hysteresis setting trimmer is moved after setting the ON pressure, it must be set again.
• OUT1 (white lead wire, red LED) can be set with pressure setting trimmer 1 (SET1).
• OUT2 (green lead wire, green LED) can be set with pressure setting trimmer 2 (SET2).
Ejector Valve Unit Series ZYY/ZYX
Set pressure
High
vacu
um
Hyste
resis ON
OFF
High p
ressur
e
Set pressure
Set pressure
Supply pressure
Atmosphericpressure
0
Hig
h va
cuum
Unstableadsorption
No adsorption
Reliable adsorption
Atmosphericpressure 0
3. Attaching and detaching of socket to connector with lead wire
Lead wireSocket
Covering retainerCore wire crimping area
Hook Covering
Core wire
Lead wire
Socket
ConnectorDC polarity indication
Lever
Hook
Hook
Lead wireSocket
ConnectorDC polarity indicationLeverPinSlotHousing
0.2 to 0.33 mm2
Max. covering dia.ø1.7 mm
0.2 to 0.33 mm2
Max. covering dia.ø1.7 mm
Hysteresis setting trimmer
Pressure setting trimmer
SET
HYSIndicator light
Indicator light SET2
SET1
Pressure setting trimmer 1
Pressure setting trimmer 2
1061
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
BB
AA
V
!0!1 r t
e
!2
!3
i w u
q
y
o
Construction
ZYY3000
Section A-A' (Ejector)
Section B-B' (Solenoid valve)
Component PartsNo.
1
2
3
4
5
6
7
8
Description Material
Resin
Zinc die-casted
Resin
Aluminum alloy
Aluminum alloy
Stainless steel
Aluminum alloy
Resin
Note
Manifold block
Body
Silencer cover
Nozzle
Diffuser
Needle
Spool
Piston
Replacement PartsNo.
9
10
11
12
13
Description Part no.
3 port solenoid valve
Vacuum pressure switch
End plate assembly
Silencer
Non plug assembly
SY114-
For without a switch
AN15-C08
ZYY3000-NPA
Series ZYY/ZYX
1062
B B
AA
BA
EXH.
V
P1
BA
B
A
o!0 r t
e
!1
w u
i
y
q
!2
Construction
ZYX3000
Section A-A' (Ejector)
Section B-B' (Solenoid valve)
Component PartsNo.
1
2
3
4
5
6
7
8
Description Material
Resin
Zinc die-casted
Resin
Aluminum alloy
Aluminum alloy
Stainless steel
Aluminum alloy
Resin
Note
Manifold block
Body
Silencer cover
Nozzle
Diffuser
Needle
Spool
Piston
Replacement PartsNo.
9
10
11
12
Description Part no.
Vacuum pressure switch
End plate assembly
Silencer
Plug assembly
For without a switch
AN15-C08
ZYY3000-PA
Ejector Valve Unit Series ZYY/ZYX
1063
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
-100
-80
-60
-40
-20
0
50
40
30
20
10
0
0 0.1 0.2 0.3 0.4 0.5 0.6
-100
-80
-60
-40
-20
0
0 10 20
-100
-80
-60
-40
-20
0
50
40
30
20
10
0
0 0.1 0.2 0.3 0.4 0.5 0.6
-100
-80
-60
-40
-20
0
0 5 10 15 20 25
-100
-80
-60
-40
-20
0
60
40
20
0
0 0.1 0.2 0.3 0.4 0.5 0.6
-100
-80
-60
-40
-20
0
0
-100
-80
-60
-40
-20
0
60
40
20
0
0 0.1 0.2 0.3 0.4 0.5 0.6
-100
-80
-60
-40
-20
0
0 10 20 30 40 505 10 15 20 25
Supply pressure (MPa) Suction flow rate (L/min(ANR))
Vac
uum
pre
ssur
e (k
Pa)
Vac
uum
pre
ssur
e (k
Pa)
Suc
tion
flow
rat
e (L
/min
(AN
R))
Air
cons
umpt
ion
flow
rat
e (L
/min
(AN
R))
Supply pressure (MPa) Suction flow rate (L/min(ANR))
Vac
uum
pre
ssur
e (k
Pa)
Vac
uum
pre
ssur
e (k
Pa)
Suc
tion
flow
rat
e (L
/min
(AN
R))
Air
cons
umpt
ion
flow
rat
e (L
/min
(AN
R))
Supply pressure (MPa) Suction flow rate (L/min(ANR))
Vac
uum
pre
ssur
e (k
Pa)
Vac
uum
pre
ssur
e (k
Pa)
Suc
tion
flow
rat
e (L
/min
(AN
R))
Air
cons
umpt
ion
flow
rat
e (L
/min
(AN
R))
Vacuum pressure
Vacuum pressure
Vacuum pressure
Vacuum pressure
Air consumption Air consumption
Air consumption
Air consumption
Suction flow rate
Suction flow rate
Suction flow rate
Suction flow rate
Supply pressure (MPa) Suction flow rate (L/min(ANR))
Vac
uum
pre
ssur
e (k
Pa)
Vac
uum
pre
ssur
e (k
Pa)
Suc
tion
flow
rat
e (L
/min
(AN
R))
Air
cons
umpt
ion
flow
rat
e (L
/min
(AN
R))
Q1
P1
Qmax
Pmax
Suction flow rate
Vac
uum
pre
ssur
e
Exhaust Characteristics/Flow Characteristics
ZY -07SExhaust Characteristics Flow Characteristics Exhaust Characteristics Flow Characteristics
Exhaust Characteristics Flow Characteristics Exhaust Characteristics Flow Characteristics
The flow rate characteristics correspond to a supply pressure of 0.45 MPa.
Y3X3 ZY -07L
Y3X3
ZY -10SY3X3 ZY -10L
Y3X3
How to Read Flow Characteristics Graph
The flow rate characteristics indicate the relationship between the vacuum pressure and the suction flow rate of the ejector, and show that when the suction flow rate changes the vacuum pressure also changes. In general, this indicates the relationship at the ejector,s standard operating pressure. In the graph, Pmax indicates the maximum vacuum pressure, and Qmax indicates the maximum suction flow rate. These are the values that are published as specifications in catalogs, etc. The methods for changing the vacuum pressure will be explained in order.1. If the ejector’s suction port is closed and sealed tight, the suction flow rate becomes “0”
and the vacuum pressure increases to the maximum (Pmax). 2. If the suction port is opened gradually and air is allowed to flow (the air leaks), the inlet
flow rate increases and the vacuum pressure decreases. (the condition of P1 and Q1)3. If the suction port is opened completely, the suction flow rate increases to the maximum
(Qmax), while the vacuum pressure then drops almost to “0” (atmospheric pressure). In this way, when the suction flow rate changes the vacuum pressure also changes. In other words, when there is no leakage at the vacuum port (vacuum piping), the vacuum pressure increases to the maximum, but the vacuum pressure drops as the amount of leakage increases, and when the amount of leakage and the maximum suction flow rate become equal, the vacuum pressure decreases nearly to “0”. When adsorbing workpieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high.
Series ZYY/ZYX
1064
P
P
P
Vacuum switch(With analog output)
P
Vacuum switch(Without analog output)
Silencer
Supply/Release valve
V
P1
Release flow rate adjusting needle
Ejector unit
(Lead wire length)
333.8
139Approx. 600
Indicator light (Red)
≅300117
55.516.5
13.5
5.25
1.4
41.649
.4
43.1
(8.25) (13.5)
58.6
67 35.3
28.5
33.6
62.1
10
2129.543
.1
(33.3)
23.5
27
(5.25)
18.8
16.8
117
55.516.5
Vacuum switch
Manual override
Manual override
Pressure setting trimmer
Hysteresis setting trimmer
Manual override
Pilot valve for supply valve
Button for block separation
Pilot valve for release valve
Release flow rateadjusting needle
Manual override
Pilot valve exhaust port
(M3: Port PE)Silencer
(AN15-C08)
End plate
(P44027A)
Manual override
Manual override
≅300
(Lead wire length)
Vacuum port
ø6 One-touch fitting Port V ( (
Air pressure supply port
( (ø6 One-touch fitting Port P1
ZYY3LZ-S1(Specifications without vacuum switch)
Circuit diagram
Ejector Valve Dimensions
ZYY3LZ-1-EC
Ejector Valve Unit Series ZYY/ZYX
1065
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
P
Vacuum switch(With analog output)
P
Vacuum switch(Without analog output)
Silencer
Supply/Release valve
V
P1
Release flow rate adjusting needle
Ejector unit
B
A
15.8
8
25
28.1
28.5
45
20
ø13
Vacuum switch
Hysteresis setting trimmer
Pressure setting trimmer
Accessory (packed together)1. Silencer (AN15-C08···1 pc.)
2. Mounting bolt nut (M2 x 0.4 x 20···4 pcs.)
Circuit diagram
Ejector Valve Dimensions
ZYY3LZ-1-EC-MN
Series ZYY/ZYX
1066
P
P
BA
BA
P
Vacuum switch(With analog output)
P
Vacuum switch(Without analog output)
Silencer
Supply/Release valve
V
P1
Release flow rate adjusting needle
Ejector unit
333.7
135
35.510.8
1.4
(8.25) (13.5)
49.4
41.6
33.6
88 19
57
33.3
23.5
27
18.8
16.8
(5.25)
62
29.5
21
10
End plate(P44027A)
10.8
Release flow rateadjusting needle
ø6 One-touch fittingPort V
Vacuum port
ø6 One-touch fittingPort P1
Air pressure supply port
(With indicator light and surge voltage suppressor)
Button for block separation
Pressure setting trimmer
Hysteresis setting trimmer
(AN15-C08)Silencer
(M3: Port PE)Pilot valve exhaust port
Vacuum switch
Approx. 600
Indicator light (Red)
Manual overrideA side: Orange (for supply valve)B side: Green (for release valve)
Manual overrideA side: Orange (for supply valve)B side: Green (for release valve)
ZYX3LOZ-1-EC
ZYX3LOZ-S1(Specifications without vacuum switch)
Circuit diagram
Ejector Valve Dimensions
Ejector Valve Unit Series ZYY/ZYX
1067
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
P
(With analog output)Vacuum switch
(Without analog output)
P
Vacuum switch
Silencer
Supply/Release valve
V
P1
Release flow rate adjusting needle
Ejector unit
ZYX3L-S-EC-F
Circuit diagram
(4)
(300
)
8
35
108.8
(19)27
67
6.73.8
- -+
V
Button for block separation
Ejector Valve Dimensions
Series ZYY/ZYX
1068
P
P
Vacuum switch(With analog output)
P
Vacuum switch(Without analog output)
Silencer
Supply/Release valve
V
P1
Release flow rate adjusting needle
Ejector unit
- -+
109
859.6
13
28.5
23.5
45
20
ø13
Accessory (packed together)
2. Mounting bolt nut (M2 x 0.4 x 25···4 pcs.)
1. Silencer (AN15-C08···1 pc)
Circuit diagram
Ejector Valve Dimensions
ZYX3L-S1-EC-FMN
Ejector Valve Unit Series ZYY/ZYX
1069
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
P
P
Vacuum switch(With analog output)
P
Vacuum switch(Without analog output)
Silencer
Supply/Release valve
V
P1
Release flow rate adjusting needle
Ejector unit
B
A
857.4
6.8
45
20
ø13
23.5
28.1
28.5
Accessory (packed together)
2. Mounting bolt nut (M2 x 0.4 x 25···4 pcs.)
1. Silencer (AN15-C08···1 pc)
Circuit diagram
Ejector Valve Dimensions
ZYX3L-S1-EC-MN
Series ZYY/ZYX
1070
ZYY3000-NPA (Non plug-in assembly)
86
33.6
27
33.3
33.6
106
27
33.3
Ejector Valve Dimensions
ZYY3000-PA (Plug-in assembly)
Ejector Valve Unit Series ZYY/ZYX
1071
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
L4
5.25
16.516.5
10.5
27 16.5
8 5.5
The length of the standard accessory DIN rail is calculated with the formula below.
C1 Value SelectionSeparate wiring type
Connector box type
D-sub connector 25 pin type
Flat cable type
Terminal block 9 pole type
Terminal block 18 pole type
33
86
(mm)
54
75
81.8
94.3
132
126
Serial transmission type
Indication exampleIn the case of ZZYY3-45-04D-C6∗SY3140-5LZ∗SY3240-5LZ∗SY3340-5LZ∗ZYY35LZ-10S-E15Cthe dimensions areL1 = 135.5 mmL2 = 125 mmL3 = 108 mmL4 = 13.75 mm
Manifold overall length (L3) = (27 x Number of ejector valve stations) + (10.5 x Number of solenoid valve stations) + (16.5 x Number of supply/exhaust block stations) + C1 [mm]Note) In the case of ejector valves only (without solenoid valves), calculate the number of solenoid valve stations and supply/exhaust block stations as “0”.Number of mounting holes (N) = (L3/12.5 + 1): Decimal fractions are truncatedDIN rail overall length (L1) = N x 12.5 + 23 [mm]Mounting screw length (L2) = L1 – 10.5 [mm]Rail length on one side (L4) = (L1 – L3)/2 [mm]
Stations
U side D side
45
45-
45F
45P
45T
45T1
45S
45S1
45S2
45S3
ANA
r ewq
Series ZYY/ZYX
Dimensions of DIN Rail Mounting Unit for ZYY3000/ZYX3000 Manifold
Ejector valve
End plate assembly L End plate assembly R
L1 : Rail overall length
L2 : Mounting screw length
L3 : Manifold overall length
DIN rail
Solenoid valve
Supply/Exhaust block
1072
1073
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
q Manifold Model
Please copy this form and use it. (Do not detach this page.)
Fill in the blanks in the order from q to r.
Fill in the blanks below with the symbols for required specifications.
Manifold Valve Specification SheetZYY3000 Individual Wiring Type
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
(Up to a total of 20 stations)Ejector/Valve stationslayout (Special specifications)
DIN rail manifold
ZZYY3
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗∗∗
SUP/EXH block assemblymounting position
45Mounting position
U sideD side
SymbolUD
Ejector mounting position
Number of ejector stations1 to 10 stations
J
U sideMounting position Applicable stations
2 to 10 stations
2 to 20 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
…2 stations
20 stations
…02StationsSymbol
20
Total number of ejector andvalve stations
A B C D
ZYY3E F G H I J K
Nil Non-locking push typePush-locking slotted type
DManual override
DPush-locking lever typeE
Nil Without light/surge voltage suppressorWith surge voltagesuppressor
CLight/Surge voltage suppressor
S
With light/surge voltage suppressorWith surge voltage suppressor(Non-polar type)With light/surge voltage suppressor(Non-polar type)
Z
R
U
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting
IOutput specifications (Vacuum switch)
15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm
ENozzle diameter
10
G Grommet (Lead wire length 300 mm)Grommet (Lead wire length 600 mm)
BElectrical entry
HWith lead wires
L plugconnector
M plugconnector
LWithout lead wiresLNWithout connectorLOWith lead wiresMWithout lead wiresMNWithout connectorMO
5 24 VDC12 VDC
DCARated voltage
66 VDCV5 VDCS3 VDCR
1 100 VAC200 VAC
AC (50/60 HZ)
2110 VAC (115 V)3220 VAC (230 V)4
S –84 kPa–53 kPa
FMax. vacuum pressure
L
Nil NoneWith silencer
GSilencer
1
Nil NoneWith vacuum switch
HVacuum switch
E
NilNoneWith manifold block
KManifold block
MN
Nil
JWiring specifications (Vacuum switch)
LLead wire length 0.6 mGrommet
type
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
U side D side
n
m t
r
r
e
e w
w
q
q
Note) • U, R: 24 VDC only.• Since surge voltage is prevent-
ed with a rectifier in the case of AC, there is no type “S”.
The number of blanking plate assembly is included.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
SUP/EXH block assemblyspecifications
For special specifications, specify using the Stations Table on the next page.
1074
e Valve ModelFill in the blanks below with the symbols for required specifications.
For SMC Use Only
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc.
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
SY3 40
NilR External pilot
Internal pilot
Pilot method
2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
Specify using the Stations Table below.
12345
Type of actuation
DA B C
Nil Non-locking push typePush-locking slotted type
DManual override
DPush-locking lever typeE
Nil Without light/surge voltage suppressorWith surge voltagesuppressor
CLight/Surge voltage suppressor
S
With light/surge voltage suppressorWith surge voltage suppressor(Non-polar type)With light/surge voltage suppressor(Non-polar type)
Z
R
U
GGrommet (Lead wire length 600 mm)Grommet (Lead wire length 300 mm)
BElectrical entry
H
L plugconnector
M plugconnector
LLNLOM
MN
With lead wiresWithout lead wiresWithout connectorWith lead wiresWithout lead wiresWithout connectorMO
5
DCARated voltage
6VS
24 VDC12 VDC6 VDC5 VDC3 VDCR
1
AC (50/60HZ)
23
100 VAC200 VAC110 VAC (115 V)220 VAC (230 V)4
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
SUP/EXH block assembly
Non-plug assembly
Blanking plate assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Fill in to orderspecial specifications.
Quantity1234567891011121314151617181920
• Individual SUP spacer assembly: SY3000-38-2A• Individual EXH spacer assembly: SY3000-39-2A• SUP/EXH block assembly (Standard): SX3000-51-1A
• SUP/EXH block assembly (R): SX3000-51-3A• SUP/EXH block assembly (S): SX3000-51-4A • SUP/EXH block assembly (RS): SX3000-51-5A
Note) • Non-plug assembly: ZYY3000-NPA• Blanking plate assembly: SX3000-75-1A• SUP blocking disk: SX3000-77-1A• EXH blocking disk: SX3000-77-1A
Two pieces usedfor one station
Note) • U, R: 24 VDC only.• Since surge voltage is prevent-
ed with a rectifier in the case of AC, there is no type “S”.
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
∗ ∗
Put "" in the blanks of "External pilot specification" in the Stations Table below to use external pilot valves.
1075
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
q Manifold ModelFill in the blanks below with the symbols for required specifications.
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 20 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45 J
A B C D
ZYX3E F G H I J K L
Nil Non-locking push typePush-locking slotted type
DManual override
D
Nil Without light/surge voltage suppressorWith surge voltagesuppressor
CLight/Surge voltage suppressor
S
With light/surge voltage suppressorZ
BElectrical entry
ARated voltageDC
NilNon plug-in typePlug-in type
KManifold type
F
LManifold block
U side D side
n
m t
r
r
e
e w
w
q
q
Fill in the blanks in the order from q to r.
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetZYX3000 Individual Wiring Type Company
Person in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
DIN rail manifold
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assemblyspecifications
SUP/EXH block assemblymounting position
Mounting positionU sideD side
SymbolUD
Ejector mounting position
Number of ejector stations1 to 10 stationsU side
Mounting position Applicable stations
2 to 10 stations
2 to 20 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
…2 stations
20 stations
…02StationsSymbol
20
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting
IOutput specifications (Vacuum switch)
15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm
ENozzle diameter
10
G Grommet (Lead wire length 300 mm)Grommet (Lead wire length 600 mm)H
With lead wiresL plugconnector
M plugconnector
LWithout lead wiresLNWithout connectorLOWith lead wiresMWithout lead wiresMNWithout connectorMO
5 24 VDC12 VDC66 VDCV5 VDCS3 VDCR
S –84 kPa–53 kPa
FMax. vacuum pressure
L
Nil NoneWith silencer
GSilencer
1
Nil NoneWith vacuum switch
HVacuum switch
E
NilNoneWith manifold block
MN
Nil
JWiring specifications (Vacuum switch)
LLead wire length 0.6 mGrommet
type
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
The number of blanking plate assembly is included. For special specifications, specify
using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
Total number of ejector andvalve stations
1076
e Valve ModelFill in the blanks below with the symbols for required specifications.
SX3 40R
DA B CNil Without light/
surge voltage suppressorWith surge voltagesuppressor
CLight/Surge voltage suppressor
S
With light/surge voltage suppressorZ
BElectrical entryARated voltage2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted type
DManual override
D
GGrommet (Lead wire length 600 mm)Grommet (Lead wire length 300 mm)
H
L plugconnector
M plugconnector
LLNLOM
MN
With lead wiresWithout lead wiresWithout connectorWith lead wiresWithout lead wiresWithout connectorMO
56VS
24 VDC12 VDC6 VDC5 VDC3 VDCR
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Non-plug assembly
Blanking plate assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity1234567891011121314151617181920
• Individual SUP spacer assembly: SY3000-38-2A
• Individual EXH spacer assembly: SY3000-39-2A
• SUP/EXH block assembly (Standard): SX3000-51-1A
• SUP/EXH block assembly (R): SX3000-51-3A
• SUP/EXH block assembly (S): SX3000-51-4A
• SUP/EXH block assembly (RS): SX3000-51-5A
Note) • Non-plug assembly: ZYY3000-NPA
• Blanking plate assembly: SX3000-75-1A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
∗SX3∗40: Internal pilotSX3∗40R: External pilot
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
SUP/EXH block assemblyFill in to orderspecial specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
1077
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
q Manifold Model
Please copy this form and use it. (Do not detach this page.)
Fill in the blanks below with the symbols for required specifications.
Manifold Valve Specification SheetFill in the blanks in the order from q to r.
ZYX3000 Terminal Block (9 Pins)
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 7 stations)Ejector/Valve stationslayout (Special specifications)
DIN rail manifold
ZZYX3 45T Ejector mounting position
Number of ejector stations1 to 3 stations
J
Mounting positionU sideD side
SymbolUD
Connector mountingposition
Total number of ejector and valve stations
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification4 stations
02Symbol
045 stations
7 stations
05
07
SUP/EXH block assemblymounting position
U sideMounting position
Both sides
UD sideD
Symbol
BSpecial specificationsM
A B C D
ZYX3 LOZE F G H I J
CManual override
HOutput specifications (Vacuum switch)DNozzle diameter
5 24 VDC12 VDC
ARated voltage
6
Nil Positive commonNegative common
BCommon specifications
N
EMax. vacuum pressure
FSilencer
GVacuum switch
JManifold block
IWiring specifications (Vacuum switch)
U side D side
n
m t
r
r
e
e w
w
q
q
CO
M1
23
46
78
5
CO
M8
76
54
32
1
Connector blockNote) Connector block is not included in the stations and layout.
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specifications
Mounting positionU sideD side
SymbolUD
……
……
Nil Non-locking push typePush-locking slotted typeD
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Match with the common specification of the manifold.
Match with the voltage specification of the manifold.
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeMFor ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
Up to 8 solenoids possible. Specify wiring specifications using the Stations Table. For special specifications, specify
using the Stations Table on the next page.
1078
Quantity1234567
e Valve ModelFill in the blanks below with the symbols for required specifications.
SX3 LOZ40R
A B C
CManual override
5 24 VDC12 VDC
ARated voltage
6Nil Positive common
Negative common
BCommon specifications
N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Wiringspecifications
Single wiringDouble wiring
Fill in only when the stations are more than five or specifying wiring specifications for four stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
Blanking plate assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Nil Non-locking push typePush-locking slotted typeD
Match with the voltage specification of the manifold.
Match with the common specification of the manifold.
∗SX3∗40: Internal pilotSX3∗40R: External pilot
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
SUP/EXH block assemblyFill in to orderspecial specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
1079
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 16 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45T1 Ejector mountingposition
Number of ejector stations1 to 8 stations
J
Total number of ejector and valve stations
A B C D
ZYX3 LOZE F G H I J
U side D side
n
m t
r
r
e
e w
w
q
q
Connector blockNote) Connector block is not included in the stations and layout.
q Manifold Model
Please copy this form and use it. (Do not detach this page.)
Fill in the blanks below with the symbols for required specifications.
Manifold Valve Specification SheetFill in the blanks in the order from q to r.
ZYX3000 Terminal Block (18 Pins)DIN rail manifold
Mounting positionU sideD side
SymbolUD
Mounting positionU sideD side
SymbolUD
Connector mountingposition
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification8 stations
02Symbol
089 stations
16 stations
09
16
CManual override
HOutput specifications (Vacuum switch)DNozzle diameter
5 24 VDC12 VDC
ARated voltage
6
Nil Positive commonNegative common
BCommon specifications
N
EMax. vacuum pressure
FSilencer
GVacuum switch
JManifold block
IWiring specifications (Vacuum switch)
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specifications
……
……
Nil Non-locking push typePush-locking slotted typeD
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Match with the common specification of the manifold.
Match with the voltage specification of the manifold.
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeMFor ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
Up to 17 solenoids possible. Specify wiring specifications using the Stations Table.
SUP/EXH block assemblymounting position
U sideMounting position Valve applicable stations
2 to 10 stations
2 to 16 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
For special specifications, specify using the Stations Table on the next page.
1080
e Valve ModelFill in the blanks below with the symbols for required specifications.
r
SX3 LOZ40R
A B C
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
Blanking plate assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity12345678910111213141516
CManual override
5 24 VDC12 VDC
ARated voltage
6Nil Positive common
Negative common
BCommon specifications
N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Match with the voltage specification of the manifold.
Match with the common specification of the manifold.
∗SX3∗40: Internal pilotSX3∗40R: External pilot
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
SUP/EXH block assemblyFill in to orderspecial specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
Wiringspecifications
Single wiringDouble wiring
1081
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
Fill in the blanks below with the symbols for required specifications.
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 7 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45 PH
Number of ejector stations1 to 3 stations
J
Positive commonNegative common
NilN
Common specifications
24 VDC12 VDC
Nil12V
Voltage
A B C D
ZYX3 LOZE F G H I J
U side D side
n
m t
r
r
e
e w
w
q
q
Connector blockNote) Connector block is not included in the stations and layout.
24VDC+COM
q Manifold Model
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetFill in the blanks in the order from q to r.
ZYX3000 Flat Ribbon Cable 10 PinsDIN rail manifold
Mounting positionU sideD side
SymbolUD
Connector mountingposition
SUP/EXH block assemblymounting position
U sideMounting position
Both sides
UD sideD
Symbol
BSpecial specificationsM
CManual override
HOutput specifications (Vacuum switch)DNozzle diameter
5 24 VDC12 VDC
ARated voltage
6
Nil Positive commonNegative common
BCommon specifications
N
EMax. vacuum pressure
FSilencer
GVacuum switch
JManifold block
IWiring specifications (Vacuum switch)
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specifications
Nil Non-locking push typePush-locking slotted typeD
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Match with the common specification of the manifold.
Match with the voltage specification of the manifold.
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
Total number of ejector and valve stations
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification4 stations
02Symbol
045 stations
7 stations
05
07
……
…… Up to 8 solenoids possible.
Specify wiring specifications using the Stations Table.
Ejector mountingposition
Mounting positionU sideD side
SymbolUD
For special specifications, specify using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
1082
e Valve ModelFill in the blanks below with the symbols for required specifications.
SX3 LOZ40R
A B C
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Quantity1234567
Fill in only when the stations are more than five or specifying wiring specifications for four stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
CManual override
5 24 VDC12 VDC
ARated voltage
6Nil Positive common
Negative common
BCommon specifications
N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Match with the voltage specification of the manifold.
Match with the common specification of the manifold.
∗SX3∗40: Internal pilotSX3∗40R: External pilot
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
Blanking plate assemblySUP/EXH block assemblyFill in to order
special specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
Wiringspecifications
Single wiringDouble wiring
1083
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45 PG
Number of ejector stations1 to 7 stations
J
Total number of ejector and valve stations
A B C D
ZYX3 LOZE F G H I J
U side D side
n
m t
r
r
e
e w
w
q
q
Connector blockNote) Connector block is not included in the stations and layout.
24VDC+COM
CManual override
HOutput specifications (Vacuum switch)DNozzle diameter
5 24 VDC12 VDC
ARated voltage
6
Nil Positive commonNegative common
BCommon specifications
N
EMax. vacuum pressure
FSilencer
GVacuum switch
JManifold block
IWiring specifications (Vacuum switch)
Nil Non-locking push typePush-locking slotted typeD
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Match with the common specification of the manifold.
Match with the voltage specification of the manifold.
Fill in the blanks below with the symbols for required specifications.
q Manifold Model
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetFill in the blanks in the order from q to r.
ZYX3000 Flat Ribbon Cable 20 PinsDIN rail manifold
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
Positive commonNegative common
NilN
Common specifications
24 VDC12 VDC
Nil12V
Voltage
Mounting positionU sideD side
SymbolUD
Connector mountingposition
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specifications
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification8 stations
02Symbol
089 stations
15 stations
09
15
……
…… Up to 16 solenoids possible.
Specify wiring specifications using the Stations Table.
Ejector mountingposition
Mounting positionU sideD side
SymbolUD
SUP/EXH block assemblymounting position
U sideMounting position Valve applicable stations
2 to 10 stations
2 to 15 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
For special specifications, specify using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
1084
e Valve ModelFill in the blanks below with the symbols for required specifications.
SX3 LOZ40R∗A B C
SX3∗40: Internal pilotSX3∗40R: External pilot
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity123456789101112131415
CManual override
5 24 VDC12 VDC
Rated voltage
6Nil Positive common
Negative common
Common specifications
N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Match with the voltage specification of the manifold.
Match with the common specification of the manifold.
Specify using the Specifications Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
Blanking plate assemblySUP/EXH block assemblyFill in to order
special specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
A B
Wiringspecifications
Single wiringDouble wiring
Plug-in assembly
1085
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
n
m t
r
r
e
e w
w
q
q
Connector blockNote) Connector block is not included in the stations and layout.
q Manifold ModelFill in the blanks below with the symbols for required specifications.
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 19 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45 P
Number of ejector stations1 to 10 stations
J
Total number of ejector and valve stations
A B C D
ZYX3 LOZE F G H I J
U side D side
Fill in the blanks in the order from q to r.
CManual override
HOutput specifications (Vacuum switch)DNozzle diameter
5 24 VDC12 VDC
ARated voltage
6
Nil Positive commonNegative common
BCommon specifications
N
EMax. vacuum pressure
FSilencer
GVacuum switch
JManifold block
IWiring specifications (Vacuum switch)
Nil Non-locking push typePush-locking slotted typeD
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Match with the common specification of the manifold.
Match with the voltage specification of the manifold.
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetZYX3000 Flat Ribbon Cable 26 PinsDIN rail manifold
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
Positive commonNegative common
NilN
Common specifications
24 VDC12 VDC
Nil12V
Voltage
Mounting positionU sideD side
SymbolUD
Connector mountingposition
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specifications
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification10 stations
02Symbol
1011 stations
19 stations
11
19
……
…… Up to 20 solenoids possible.
Specify wiring specifications using the Stations Table.
Ejector mountingposition
Mounting positionU sideD side
SymbolUD
SUP/EXH block assemblymounting position
U sideMounting position Valve applicable stations
2 to 10 stations
2 to 19 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
For special specifications, specify using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
1086
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Fill in only when the stations are more than eleven or specifying wiring specifications for ten stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity12345678910111213141516171819
SX3 LOZ40R
A B C
CManual override
5 24 VDC12 VDC
ARated voltage
6Nil Positive common
Negative common
BCommon specifications
N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Match with the voltage specification of the manifold.
Match with the common specification of the manifold.
∗e Valve Model
Fill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilotSX3∗40R: External pilot
Specify using the Specifications Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
Blanking plate assemblySUP/EXH block assemblyFill in to order
special specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
Wiringspecifications
Single wiringDouble wiring
1087
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
q Manifold ModelFill in the blanks below with the symbols for required specifications.
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 19 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45 F J
A B C D
ZYX3 LOZE F G H I J
U side D side
n
m t
r
r
e
e w
w
q
q
Connector blockNote) Connector block is not included in the stations and layout.
24VDC+COM
Fill in the blanks in the order from q to r.
Number of ejector stations1 to 10 stations
Total number of ejector and valve stations
CManual override
HOutput specifications (Vacuum switch)DNozzle diameter
5 24 VDC12 VDC
ARated voltage
6
Nil Positive commonNegative common
BCommon specifications
N
EMax. vacuum pressure
FSilencer
GVacuum switch
JManifold block
IWiring specifications (Vacuum switch)
Nil Non-locking push typePush-locking slotted typeD
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Match with the common specification of the manifold.
Match with the voltage specification of the manifold.
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetZYX3000 D-sub ConnectorDIN rail manifold
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
Positive commonNegative common
NilN
Common specifications
24 VDC12 VDC
Nil12V
Voltage
Mounting positionU sideD side
SymbolUD
Connector mountingposition
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specifications
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification10 stations
02Symbol
1011 stations
19 stations
11
19
……
…… Up to 20 solenoids possible.
Specify wiring specifications using the Stations Table.
Ejector mountingposition
Mounting positionU sideD side
SymbolUD
SUP/EXH block assemblymounting position
U sideMounting position Valve applicable stations
2 to 10 stations
2 to 19 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
For special specifications, specify using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
1088
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Fill in only when the stations are more than eleven or specifying wiring specifications for ten stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity12345678910111213141516171819
SX3 LOZ40R
A B C
CManual override
5 24 VDC12 VDC
ARated voltage
6Nil Positive common
Negative common
BCommon specifications
N2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Match with the voltage specification of the manifold.
Match with the common specification of the manifold.
∗e Valve Model
Fill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilotSX3∗40R: External pilot
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
Blanking plate assemblySUP/EXH block assemblyFill in to order
special specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
Wiringspecifications
Single wiringDouble wiring
1089
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
q Manifold ModelFill in the blanks below with the symbols for required specifications.
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45S
Number of ejector stations1 to 7 stations
J
Protocol typeWithout SI unitNKE Corp.: Fieldbus SystemNKE Corp.: Fieldbus H SystemPanasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)DeviceNetTM
OMRON Corp.: CompoBus/S (16 outputs) compatibleOMRON Corp.: CompoBus/S (8 outputs) compatibleCC-LINKCompoNetTM
Symbol0
F1HJ1J2QR1R2V
ZB
SI unit specifications
A B C
ZYX3 5 LOZD E F G H J
BManual override
ACommon specifications
Ratedvoltage24 VDC
U side D side
n
m t
r
r
e
e w
w
q
q
Fill in the blanks in the order from q to r.
GOutput specifications (Vacuum switch)CNozzle diameter
Nil Positive commonNegative commonN
DMax. vacuum pressure
ESilencer
FVacuum switch
JManifold block
HWiring specifications (Vacuum switch)
Nil Non-locking push typePush-locking slotted typeD
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Match with the common specification of the manifold.
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetZYX3000 Serial Wiring Type (Bar Stock Type)DIN rail manifold
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specifications
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification8 stations
02Symbol
089 stations
15 stations
09
15
……
…… Up to 16 solenoids possible.
Specify wiring specifications using the Stations Table.
Ejector mountingposition
Mounting positionU sideD side
SymbolUD
SUP/EXH block assemblymounting position
U sideMounting position Valve applicable stations
2 to 10 stations
2 to 15 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
For special specifications, specify using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
Total number of ejector and valve stations
1090
SX3 LOZ540R
A
AManual overrideRated voltage24 VDC
e Valve ModelFill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilot
SX3∗40R: External pilot
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity123456789101112131415
2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
Blanking plate assemblySUP/EXH block assemblyFill in to order
special specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
∗
Wiringspecifications
Single wiringDouble wiring
1091
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
q Manifold ModelFill in the blanks below with the symbols for required specifications.
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45S1
Number of ejector stations1 to 7 stations
J
Total number of ejector and valve stations
SI unit mounting position
A B C
ZYX3 5 LOZD E F G H J
U side D side
n
m t
r
r
e
e w
w
q
q
Connector blockNote) Connector block is not included in the stations and layout.
Fill in the blanks in the order from q to r.
Protocol typeWithout SI unitNKE Corp.: Fieldbus SystemNKE Corp.: Fieldbus H SystemPanasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs)Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs)DeviceNetTM
OMRON Corp.: CompoBus/S (16 outputs) compatibleOMRON Corp.: CompoBus/S (8 outputs) compatibleCC-LINKCompoNetTM
Symbol0
F1HJ1J2QR1R2V
ZB
SI unit specifications
Ratedvoltage24 VDC
GOutput specifications (Vacuum switch)CNozzle diameter
DMax. vacuum pressure
ESilencer
FVacuum switch
JManifold block
HWiring specifications (Vacuum switch)
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetZYX3000 Serial Wiring Type (Separated)DIN rail manifold
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗
∗
SUP/EXH block assembly specifications
A, B port size (valve only)Specifications
One-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification8 stations
02Symbol
089 stations
15 stations
09
15
……
…… Up to 16 solenoids possible.
Specify wiring specifications using the Stations Table.
Ejector mountingposition
Mounting positionU sideD side
SymbolUD
Mounting positionU sideD side
SymbolUD
SUP/EXH block assemblymounting position
U sideMounting position Valve applicable stations
2 to 10 stations
2 to 15 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
BManual override
ACommon specifications
Nil Positive commonNegative commonN
Nil Non-locking push typePush-locking slotted typeD
Match with the common specification of the manifold.
For special specifications, specify using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
1092
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SXY3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity123456789101112131415
SX3 LOZ540R
A
AManual overrideRated voltage24 VDC
e Valve ModelFill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilot
SX3∗40R: External pilot
2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
Blanking plate assemblySUP/EXH block assemblyFill in to order
special specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
∗
Wiringspecifications
Single wiringDouble wiring
1093
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
q Manifold ModelFill in the blanks below with the symbols for required specifications.
w Ejector Valve ModelFill in the blanks below with the symbols for required specifications.
(Up to a total of 15 stations)Ejector/Valve stationslayout (Special specifications)
ZZYX3 45S2Number of ejector stations1 to 7 stations
J
Total number of ejector and valve stationsWith transmission unitWithout transmission unit
Nil0
Unit
A B C
ZYX3 5 LOZD E F G H J
U side D side
n
m t
r
r
e
e w
w
q
q
Connector blockNote) Connector block is not included in the stations and layout.
Fill in the blanks in the order from q to r.
Ratedvoltage24 VDC
GOutput specifications (Vacuum switch)CNozzle diameter
DMax. vacuum pressure
ESilencer
FVacuum switch
JManifold block
HWiring specifications (Vacuum switch)
14 NPN open collector 1 output,without analog output, 3 turn settingNPN open collector 1 output,without analog output, 200 degree setting15
NPN open collector 2 outputs,without analog output, 3 turn settingNPN open collector 2 outputs,without analog output, 200 degree settingNPN open collector 1 output,with analog output, 3 turn settingNPN open collector 1 output,with analog output, 200 degree settingPNP open collector 1 output,without analog output, 200 degree setting
16
17
18
19
55
07 ø0.7 mmø1.0 mm10
S –84 kPa–53 kPaL
Nil NoneWith silencer1
Nil NoneWith vacuum switchE
NilNoneWith manifold block
MN
NilL
Lead wire length 0.6 mGrommettype
Connectortype
Lead wire length 3 mLead wire length 0.6 mLead wire length 3 mConnector type
CCLCN
BManual override
ACommon specifications
Nil Positive commonNegative commonN
Nil Non-locking push typePush-locking slotted typeD
Match with the common specification of the manifold.
Please copy this form and use it. (Do not detach this page.)
Manifold Valve Specification SheetZYX3000 Serial Transmission Unit (For OMRON Corp.)DIN rail manifold (G71-0D16)
CompanyPerson in chargeSheet No.Order No.EquipmentQuantity Set Date of delivery
Date: / / (YY/MM/DD)
Mounting positionU sideD side
SymbolUD
SI unit mountingposition
SpecificationsStandard/Internal pilot specificationExternal pilot specification
∗ : Made to Order
SymbolNilR
Internal pilot/Built-in silencerSExternal pilot/Built-in silencerRS
∗ ∗ ∗
SUP/EXH block assembly specificationsA, B port size (valve only)
SpecificationsOne-touch fitting for ø4One-touch fitting for ø6
SymbolC4C6
Mixed sizeM
2 stationsStations Note
The number of blanking plate assembly is included.
Double wiring specification8 stations
02Symbol
089 stations
15 stations
09
15
……
…… Up to 16 solenoids possible.
Specify wiring specifications using the Stations Table.
Ejector mountingposition
Mounting positionU sideD side
SymbolUD
SUP/EXH block assemblymounting position
U sideMounting position Valve applicable stations
2 to 10 stations
2 to 15 stationsBoth sides
UD sideD
Symbol
BSpecial specificationsM
For special specifications, specify using the Stations Table on the next page.
For ordering the mixed size, put C4 or C6 respectively instead of "" in the Stations Table.
1094
• Individual SUP spacer assembly: SX3000-38-3A
• Individual EXH spacer assembly: SX3000-39-3A
• SUP/EXH block assembly (Standard): SX3000-51-2A
• SUP/EXH block assembly (R): SX3000-51-6A
• SUP/EXH block assembly (S): SX3000-51-7A
• SUP/EXH block assembly (RS): SX3000-51-8A
Note) • Plug-in assembly: ZYY3000-PA
• Blanking plate assembly: SX3000-75-2A
• SUP blocking disk: SX3000-77-1A
• EXH blocking disk: SX3000-77-1A
Fill in only when the stations are more than nine or specifying wiring specifications for eight stations or less is required.
Valve stations or Layout
Eje
ctor
spe
cific
atio
nsV
alve
spe
cific
atio
ns
Noz
zle
diam
eter
07
Noz
zle
diam
eter
10
Acces
sory
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Vacu
um pr
essu
re S
Vacu
um pr
essu
re L
Withsilencer
Withoutsilencer
Withsilencer
Withoutsilencer
Withsilencer
WithoutsilencerWithsilencer
Withoutsilencer
With switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switchWith switchWithout switch
Single solenoidDouble solenoidCosed centerExhaust centerPressure center
Plug-in assembly
SUP blocking diskEXH blocking disk
A, B port size (Mixed specifications)
Individual SUP spacer assemblyIndividual EXH spacer assembly
2 position
3 position
Quantity123456789101112131415
SX3 LOZ540R
A
AManual overrideRated voltage24 VDC
e Valve ModelFill in the blanks below with the symbols for required specifications. SX3∗40: Internal pilot
SX3∗40R: External pilot
2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center
12345
Type of actuation
Nil Non-locking push typePush-locking slotted typeD
Specify using the Stations Table below.
r Stations TablePut "" at stations needed for the arrangement of ejectors, valves, etc. (For mixed sizes of A, B port size, put C4 or C6 in the row of a.)
Blanking plate assemblySUP/EXH block assemblyFill in to order
special specifications.
Two pieces usedfor one station
For SMC Use Only
Model No. Qty. Model No. Qty. Customer code
Code for person in charge
Departmental code
Note) Put down the model number and quantity of SUP/EXH block assemblies with the mani fo ld mode l number when the mounting positions of SUP/EXH block assemblies are special specifications.
a
∗
Wiringspecifications
Single wiringDouble wiring
1095
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX
WiringDesign/Selection
Warning Warning
Mounting
Warning
WarningPressure Source
1. Use with the specified voltage.Use with voltage outside of the specifications can cause malfunction or switch damage, as well as electrocution and fire hazard, etc.
2. Never use a load which exceeds the maximum load capacity.This may damage a switch or reduce its service life.
3. Do not use a load that generates surge voltage.Although a zener diode for surge protection is connected at the output side of a switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch having a built-in surge absorbing element.
4. Be sure to confirm the fluid specifications.Since switches do not have explosion-proof construction, do not use flammable gases or fluids. This may cause a fire or explosion.
5. Be certain to observe the regulating pressure range and maximum operating pressure.Operation at a pressure outside of this range can cause failure. In addition, the switch will be broken if operated above the maximum operating pressure.
1. Confirm wire colors and terminal numbers when wiring is performed.Since incorrect wiring can lead to breakage or failure of the switch as well as malfunction, perform wiring after confirming wiring colors and terminal numbers with the instruction manual.
2. Avoid repeatedly bending or stretching lead wires.Broken lead wires will result from applying bending stress or stretching force to the lead wires. In the event that lead wires are damaged creating a possibility of malfunction, replace the entire product. (For cases in which the lead wires cannot be replaced through grommets.)
3. Confirm proper insulation of wiring.Be certain that there is no faulty wiring insulation (contact with other circuits, ground fault, improper insulation between terminals, etc.). Damage may occur due to excess currect flow into a switch.
4. Do not wire power lines or high voltage lines.Wire separately from power lines or high voltage lines, avoiding pararell wiring or wiring in the same conduit with these lines. Control circuits, including switches, may malfunc-tion due to noise from these other lines.
5. Do not allow short circuiting of loads.Use caution, as switches will be damaged instantly if a load is short circuited. Be especially careful not to reverse the power supply line (Brown) and the output line (Black).
1. Do not use until you can verify that equipment can operate properly.Verify correct mounting by suitable function and leakage inspections after air and power are connected following mount-ing, maintenance or conversions.
2. Do not drop or bump.Do not drop, bump or apply excessive impact (1000 m/s2) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction.
3. Hold the product from the body side when handling.The tensile strength of the power cord is 49 N, and pulling it with a force greater than this can cause failure. Hold by the body when handling.
4. Turn the setting trimmer gently using a watchmakers screw driver.Turn the setting trimmer gently using a watchmakers screw driver. Do not turn beyond the stoppers located at both sides. If the trimmer is broken, adjustment will be impossible.
5. Pressure portDo not insert wire, etc, from the pressure port. This will damage the pressure sensor, making it impossible to obtain normal operation.
1. Observe the fluid and ambient temperature ranges. The fluid and ambient temperatures are 5 to 50°C. Moisture in circuits can freeze at 5°C or below, causing damage to O-rings, and malfunction. Consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits. Furthermore, even though the ambient temperature range remains within specifications, do not operate in locations where there are abrupt temperature changes.
2. Vacuum pressure switches There will be no change in performance if a pressure of 0.5 MPa or less is applied for 1 second or less (when releasing a vacuum), but care should be taken that pressures of 0.2 MPa or more are not regularly applied.
Series ZYY/ZYXElectronic Pressure SwitchesSpecific Product Precautions 1Be sure to read before handling.
1096
Maintenance
WarningOperating Environment
Warning
Piping Operating Environment
Caution Caution
Operation of Ejector Valves
Caution
Solenoid Valves (Series SY3000/SX3000)
Caution
Serial Wiring
Caution
Precautions
1. Never use in an atmosphere of explosive gases.The strucuture of pressure switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion.
2. Do not use in locations with sources of surge generation. When equipment that generates a large amount of surge (solenoid type lifters, high frequency induction furnaces, motors, etc.) is located in the area around a pressure switch, thers is a danger of deterioration or damage to the switch’s internal circuit elements. Therefore, implement surge countermeasures at the sources, and avoid the mixing and touching of lines.
3. Operating environmentSince the electronic pressure switch is basically an open type, avoid use in locations where there is a scattering of water or oil, etc.
1. Perform maintenance regularly. It may otherwise not be possible to assure safety due to unexpected malfunction or misoperation, etc.
2. When used in an interlock circuit When used in an interlock circuit, provide multiple interlock circuits as a precaution against failure, and also perform regular inspections to confirm normal operation.
3. When the body requires cleaning Use a soft cloth to clean the case. In case of heavy soiling, wipe it off with a cloth soaked in a neutral detergent diluted with water after wringing it out thoroughly, and finish up by wiping with a dry cloth.
1. Connect the compressed air supply piping separately to the solenoid valves and ejector valves. Also, connect each ejector valve to separate piping system.
1. When the pilot valve for air supply is turned ON, the main valve switches, and vacuum is generated by the flow of compressed air from the nozzle to the diffuser. When the pilot valve for vacuum release is turned ON, the main valve switches, and the vacuum is quickly released as air passes through the release flow adjustment needle and flows to the vacuum port. When the pilot valve for air supply and the pilot valve for vacuum release are both OFF, the main valve is in a closed state in the center position.
1. Avoid use exposed to direct sunlight.
1. Refer to Best Pneumatics No. 1 and SMC website for Specific Product Precautions for solenoid valves (Series SY3000/SX3000).
1. Serial wiring is possible only for the solenoid valve section. Wire the vacuum switch separately.
Be sure to read before handling.Refer to front matter 35 for Safety Instructions and pages 899 to 901 for Vacuum Equipment Precautions.
Series ZYY/ZYXElectronic Pressure SwitchesSpecific Product Precautions 2Be sure to read before handling.
1097
ZK2
ZQ
ZR
ZA
ZX
ZM
ZMA
ZL
ZH
ZUZYYZYXZYYZYX