Date post: | 04-Jun-2018 |
Category: |
Documents |
Upload: | sarvarrasheed |
View: | 219 times |
Download: | 0 times |
of 24
8/13/2019 ElectricalHazardAwareness
1/24
www.dmp.wa.gov.au/ResourcesSafety
This PowerPoint has been produced for public use by
Resources Safety staff.
The content has been approved for external presentation
by the Director Mines Safety and Manager SafetyCommunications, and must not to be amended without
their permission.
Please read this before using presentation
8/13/2019 ElectricalHazardAwareness
2/24
www.dmp.wa.gov.au/ResourcesSafety
www.dmp.wa.gov.au/ResourcesSafety
Electrical hazard awareness
8/13/2019 ElectricalHazardAwareness
3/24
www.dmp.wa.gov.au/ResourcesSafety
What does hazard mean?
Hazard means:
any potential or actual threat to the wellbeing of people,
machinery or environment
Electrical hazard safety means:
taking precautions to identify and control electrical hazards
8/13/2019 ElectricalHazardAwareness
4/24
www.dmp.wa.gov.au/ResourcesSafety
Why know about it?
Because failing to take the necessary precautions can lead to:
injury or death
fire or property damage
8/13/2019 ElectricalHazardAwareness
5/24
www.dmp.wa.gov.au/ResourcesSafety
What are the safety priorities?
Electrical hazards exist in almost every workplace. Common
causes of electrocution are:
making contact with overhead wires
undertaking maintenance on live equipment working with damaged electrical equipment, such as extension
leads, plugs and sockets
using equipment affected by rain or water ingress
8/13/2019 ElectricalHazardAwareness
6/24
www.dmp.wa.gov.au/ResourcesSafety
How do you respond to electrical incidents?
If you come across a person receiving an electric shock:
if possible, disconnect the electrical supply (switch?)
assess the situationnever put yourself at risk
take precautions to protect yourself and anyone else in thevicinity
apply the first aid principles (e.g. DRSABCD)
assess the injuries and move the casualty to a safe area if
required administer first aid if trained
seek urgent medical attention
8/13/2019 ElectricalHazardAwareness
7/24 www.dmp.wa.gov.au/ResourcesSafety
Do you want to be a victim?
You could be the victim if you:
dont follow proper procedures around electricity
use electrical equipment improperly
use faulty electrical equipment
8/13/2019 ElectricalHazardAwareness
8/24 www.dmp.wa.gov.au/ResourcesSafety
What are the types of injuries?
Burns
Shocks
Falls
KEEP SAFE
KNOW HOW TO CONTROL ELECTRICAL HAZARDS
8/13/2019 ElectricalHazardAwareness
9/24 www.dmp.wa.gov.au/ResourcesSafety
What are the levels of effect of current?
AC current (mA) Effect on human body
1 Slight tingling sensation
2-9 Small shock
10-24 Muscles contract causing you to freeze
25-74 Respiratory muscles can become
paralysed; pain; exit burns often visible
75-300 Usually fatal; ventricular fibrillation; entry &
exit wounds visible
>300 Death almost certain; if survive will have
badly burnt organs and probably require
amputations
8/13/2019 ElectricalHazardAwareness
10/24 www.dmp.wa.gov.au/ResourcesSafety
What should you do in an electrical emergency?
For low voltage electricity >50 V AC and 110 V DC
remove the source of electricity supply
commence CPR if trained
call the emergency number on site
For high voltage electricity >1000 V
call the emergency number for your site
dont go near the casualty dont touch the casualty or try to free them with anything
8/13/2019 ElectricalHazardAwareness
11/24 www.dmp.wa.gov.au/ResourcesSafety
Should you report electrical incidents?
Electricity is invisiblethis in itself makes it dangerous
It has great potential to seriously injure or kill
The company has a duty of care to its employees and
contractors Everyone is exposed to electrical hazards, not just electricians
Report all electrical shocks and near misses
ALL EMPLOYEES CAN BE EXPOSED TO ELECTRICALHAZARDS. THEY SHOULD RECEIVE ELECTRICAL HAZARD
TRAINING AT THE COMMENCEMENT OF THEIR
EMPLOYMENT AND REGULAR REFRESHER TRAINING.
8/13/2019 ElectricalHazardAwareness
12/24
8/13/2019 ElectricalHazardAwareness
13/24 www.dmp.wa.gov.au/ResourcesSafety
What are other safety measures?
Heed warning signs
Use the right equipment
Study the operation manual
Take care of extension leads
Use only approved extension lamps
Dont pull on leads
Use residual current devicesRCDs
Use the proper fuses and circuit breakers
8/13/2019 ElectricalHazardAwareness
14/24 www.dmp.wa.gov.au/ResourcesSafety
Regular safety inspections
are a part of YOUR job...
Electrical equipment should be checked each time
before use for defects
If not tagged or the tag is out of date then report it andplace it out of service
8/13/2019 ElectricalHazardAwareness
15/24 www.dmp.wa.gov.au/ResourcesSafety
Should you be aware of powerlines?
Do you know if there are overhead powerlines on your site?
Do you know where they are located?
Do you know what the safe work clearance is?
Strict regulations are laid down to cover any work that may haveto be performed close to overhead powerlines
8/13/2019 ElectricalHazardAwareness
16/24 www.dmp.wa.gov.au/ResourcesSafety
What is a powerline corridor?
MSI Regulation 5.28 defines a powerline corridor as the area under
any overhead powerline that has not been properly isolated, and 10
metres either side of the powerline.
It is essential that these areas are respected. They are there for
the safety of everyone Do not store equipment, machinery, buildings
or structures in powerline corridors
Do not construct, fabricate or maintain
structures, buildings, machinery or
equipment in powerline corridors
LOOK UP AND LIVE
8/13/2019 ElectricalHazardAwareness
17/24 www.dmp.wa.gov.au/ResourcesSafety
Can a powerline be approached safely?
Up to and including to 33 kV
2.3 m when passing underneath and 3 m when passing to the side
Above 33 kV
4 m when passing underneath and 6 m when passing to the side
8/13/2019 ElectricalHazardAwareness
18/24 www.dmp.wa.gov.au/ResourcesSafety
Who can access substations?
Only trained and authorised personnel may enter and work
inside a substation
To enter a substation you must complete the substation entry
training
Access is restricted for any cabinet with exposed energized parts
ALL ELECTRICAL WORK MUST TO BE RECORDED AND
ENTERED INTO THE ELECTRICAL MINES RECORD BOOK,
AND THE ELECTRICAL SUPERVISOR INFORMED
8/13/2019 ElectricalHazardAwareness
19/24 www.dmp.wa.gov.au/ResourcesSafety
What are electric shock hazards?
Arc welding can and has killed people in high risk environments
Everyone involved needs to better understand the hazards,
adopt sound practice and use appropriate safety devices
Study and adhere to the Code of Practice: WTIA Tech Note 7-04
Use safety devices such as manual trigger switches and voltage
reducing devices (VRDs)
Under adverse conditions, strive to improve control measures
(e.g. presence of moisture as sweat or rain)
8/13/2019 ElectricalHazardAwareness
20/24
www.dmp.wa.gov.au/ResourcesSafety
A welding incident
Assistant hands welder a metal object.
Resultant current is 35 mA
I = V/R = 67/1900 = 35 mA
Result = Assistant survived but welder died
8/13/2019 ElectricalHazardAwareness
21/24
www.dmp.wa.gov.au/ResourcesSafety
Do you have permission to dig?
Be aware of the potential hazard from buried electrical cables for
the following activities:
excavation
drilling
trenching
levelling
digging
driving of stakes or pegs
Do not commence excavation work near buried cables unless a
permit has been issued by an authorised person
Do you know what precautionary measures need to be taken?
8/13/2019 ElectricalHazardAwareness
22/24
www.dmp.wa.gov.au/ResourcesSafety
What risk assessment?!
8/13/2019 ElectricalHazardAwareness
23/24
www.dmp.wa.gov.au/ResourcesSafety
Is this a problem?
8/13/2019 ElectricalHazardAwareness
24/24
d /R S f t
The key messages are
The risk of electric shock from correctly installed and maintained
power sources is negligible, provided that sensible precautions
are taken by the operator and correct work procedures are
followed
Ensure that the right person is carrying out electrical worklicensed versus competent
Electricity is essential but, improperly used, it can be DEADLY!
To STAY ALIVE, you have to STAY ALERT