26/05/2014
Electromagnetic Radiation (EMR) Testing Report Twenty-Five Schools, Peel District School Board
G2S13600
Peel District School Board 5650 Hurontario Street Mississauga, Ontario L5R 1C6
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
i
Executive Summary
G2S Environmental Consulting Inc. (G2S) was retained by Peel District School Board (PDSB) to complete electromagnetic radiation (EMR) testing of twenty-five school buildings within the PDSB.
PDSB recently installed Wi-Fi computer networks in all the elementary and secondary schools within the board. The installation started in July 2012 and was completed by the end of the 2012/2013 school year. Wi-Fi access points were installed at ceiling level at various locations throughout the schools. The objective of the testing was to assess the levels of radiofrequency (RF) emissions associated with the Wi-Fi equipment and compare the collected data to the exposure limits specified in Health Canada’s Safety Code 6.
A total of 551 locations were measured at the twenty-five school buildings. All measurements were well below the Safety Code 6 limit of 10 W/m2 (for frequency ranges between 1500 to 15000 MHz). On average, the RF measurements were higher when the Wi-Fi equipment was turned on compared to when it was turned off, which is expected.
Both the background RF levels (Wi-Fi network “off”) and the total RF levels (Wi-Fi network “on”) showed values typical for residential areas of relatively low population density. Note that higher population density usually relates to higher RF activity, especially when cell towers are present.
Based on the findings of this survey, the RF measurements in the areas tested are well within the limits set by Health Canada Safety Code 6 (2009). The need for further investigations has not been identified at this time.
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
ii
Table of Contents Executive Summary ..................................................................................................................... i 1.0 Introduction ...................................................................................................................... 1 2.0 Background ...................................................................................................................... 1
2.1 Radio Frequency and Wi-Fi Background ....................................................................... 1 2.2 PDSB Wi-Fi Equipment System .................................................................................... 2
3.0 Objective and Scope of Work ........................................................................................... 2 4.0 Health Canada’s Safety Code 6 (2009) ............................................................................ 2 5.0 Methodology ..................................................................................................................... 4
5.1 Preliminary Site Visit ..................................................................................................... 4 5.2 Measurement Equipment .............................................................................................. 4 5.3 Measurement Locations ................................................................................................ 6
6.0 Data Evaluation ................................................................................................................ 7 7.0 Conclusion and Recommendations .................................................................................. 9 8.0 Qualifications of the Reviewer .......................................................................................... 9 9.0 References ....................................................................................................................... 9 10.0 Limitations ...................................................................................................................... 10 11.0 Closing Remarks ............................................................................................................ 10
Attachments
Attachment A: Summary Table Attachment B13: Huttonville P.S. Attachment B1: Allan Drive M.S. Attachment B14: Kenollie P.S. Attachment B2: Belfountain P.S. Attachment B15: Lorne Park S.S. Attachment B3: Castlebrooke S.S. Attachment B16: Lougheed M.S. Attachment B4: Cawthra Park S.S. Attachment B17: Meadowvale S.S. Attachment B5: Central Peel S.S. Attachment B18: Middlebury P.S. Attachment B6: Dorset Drive P.S. Attachment B19: Mineola P.S. Attachment B7: Fallingbrook M.S. Attachment B20: Morning Star M.S. Attachment B8: Fletcher’s Meadow S.S. Attachment B21: North Park S.S. Attachment B9: Glenforest S.S. Attachment B22: Port Credit S.S. Attachment B10: Herb Campbell P.S. Attachment B23: Queen Elizabeth Sr. P.S. Attachment B11: Hillcrest M.S. Attachment B24: SouthFields Village P.S. Attachment B12: Humberview S.S. Attachment B25: William G. Davis Sr. P.S.
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
1
1.0 Introduction
G2S Environmental Consulting Inc. (G2S) was retained by Peel District School Board (PDSB) to complete electromagnetic radiation (EMR) surveys at the following twenty-five school buildings.
• Allan Drive M.S. • Belfountain P.S. • Castlebrooke S.S.
• Cawthra Park S.S. • Central Peel S.S. • Dorset Drive P.S.
• Fallingbrook M.S. • Fletcher’s Meadow S.S. • Glenforest S.S.
• Herb Campbell P.S. • Hillcrest M.S. • Humberview S.S.
• Huttonville P.S. • Kenollie P.S. • Lorne Park S.S.
• Lougheed M.S. • Meadowvale S.S. • Middlebury P.S.
• Mineola P.S. • Morning Star M.S. • North Park S.S.
• Port Credit S.S. • Queen Elizabeth Sr. P.S. • SouthFields Village P.S.
• William G. Davis Sr. P.S.
PDSB recently installed Wi-Fi computer networks in all the elementary and secondary schools within the board. The installation started in July 2012 and was completed by the end of the 2012/2013 school year. Wi-Fi access points were installed at ceiling level at various locations throughout the schools. The objective of the EMR testing was to assess the levels of radiofrequency (RF) emissions associated with the Wi-Fi equipment and compare the collected data to the exposure limits specified in Health Canada’s Safety Code 6.
2.0 Background
2.1 Radio Frequency and Wi-Fi Background
Radio frequency is defined as any electromagnetic wave frequencies that range from 3 kHz to 300 GHz. RF power is often emitted from devices such as cell phones, medical devices, radar, and from radio and television broadcasting (Health Canada, 2009).
Wi-Fi is a trademark of the Wi-Fi Alliance and defines Wi-Fi as any wireless local area network (WLAN) product that is based on the Institute of Electrical and Electronics Engineers (IEEE) 802.11 standards (Industry Canada, 2012). Wi-Fi networks use radio technologies called 802.11 to provide secure, reliable, and fast wireless connectivity. A Wi-Fi network can be used to connect electronic devices to each other, to the Internet, and to wired networks which use ethernet technology. Wi-Fi networks operate in the 2.4 GHz frequency band (from 2.400 GHz to 2.484 GHz) and in the 5 GHz band (from 5.725 GHz to 5.825 GHz), with some products that can operate in both bands (dual band).
A device that can use Wi-Fi (such as a personal computer, video-game console, smartphone, digital camera, tablet, or digital audio player) can connect to a network resource such as the Internet via a wireless network access point. Such an access point (or hotspot) has a range of about 20 meters (65 feet) indoors and typically consists of one or more low power transmitters installed at the ceiling level.
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
2
2.2 PDSB Wi-Fi Equipment System
The Wi-Fi equipment (access points) installed at the twenty-five schools consisted of Cisco AP3500e and AP1260 devices. The locations of the access points for each school are shown on the corresponding drawings provided in Attachments B1 to B25. The installed Wi-Fi equipment operate in the frequency range between 2.4 GHz and 5.825 GHz.
3.0 Objective and Scope of Work
The objective of the investigation was to evaluate the RF exposure levels from the Wi-Fi computer network at each school and compare the measurements to Health Canada’s Safety Code 6 exposure limits. More information regarding the Safety Code 6 limits is provided in Section 4 and a methodology of our survey is provided in Section 5.
In general, the scope of work for the survey included the following:
1. Completion of a preliminary Site visit for each location to establish sampling locations;
2. Review of all existing EMR sources within an approximate 250 m radius of each Site;
3. Conduct testing using a Narda Broadband Field Meter NBM-550 equipped with a NAR-EC5091 300 kHz - 50 GHz Shaped E-Field Probe, SC6 Canada, Isotropic;
4. Collection of RF readings from various locations throughout the schools with and without the wireless network equipment signals present;
5. Data evaluation with respect to Safety Code 6 exposure limits; and
6. Preparation of a report detailing the RF measurement results.
4.0 Health Canada’s Safety Code 6 (2009)
Guidelines for acceptable levels of RF exposure for the protection of human health are outlined in the 2009 Health Canada document entitled “Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 kHz to 300 GHz” (Safety Code 6). The purpose of Safety Code 6 is to establish safety limits for human exposure to RF electromagnetic energy in the frequency range from 3 kHz to 300 GHz. Limits of exposure to RF energy in the code concerning the general public were set to a minimum of fifty times lower than the levels where potential harmful effects (alterations in core-body temperature of about 1° C) could take place.
Safety Code 6 has specified two types of exposure limits: (i) exposure in a controlled environment and (ii) exposure in an uncontrolled environment. The first type of limit addresses the maximum permissible exposures (MPEs) for employees in the RF/communications industry, where exposure is a component of their job and is, therefore, predictable and carefully monitored. The second type of limit addresses the exposure of the general public, which can occur at any arbitrary location (public or private) and which, therefore, cannot be controlled or monitored on a regular basis. The applicable limit for this investigation is exposure in an uncontrolled environment.
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
3
The recommended exposure levels are regulated through: (a) the specific absorption rate (SAR) limits, and (b) the field strength or the power density limits, depending on the frequency range. SAR is a measurement of the rate at which electromagnetic energy is absorbed in the body and is measured in Watts per kilogram (W/kg). The SAR is typically determined for situations where exposures occur at a distance of 0.2 m or less from the source and is applicable for persons classified as RF and microwave workers. For conditions where SAR determination is impractical (this is usually the case of the uncontrolled environment), field strength and power density limits are applied. Section 2.2 of Safety Code 6 specifies exposure limits for persons NOT classified as RF and microwave workers (the general public) in terms of electric field strength and power density for frequencies greater than 100 MHz. Below 100 MHz, the limits are specified only in terms of electric and magnetic field strengths. The maximum allowed spatial average values in an uncontrolled environment are summarized in Table 1 in the relevant frequency bands. Note that the probe used in the current survey is specifically designed to report the RF emissions relative to Safety Code 6 in the frequency range from 300 kHz (or 0.3 MHz) to 50 GHz (or 50 000 MHz).
TABLE 1: EXPOSURE LIMITS FOR UNCONTROLLED ENVIRONMENTS ACCORDING TO SAFETY CODE 6
Frequency f (MHz)
E-field strength, rms (V/m)
H-field strength, rms (A/m)
Power Density (W/m2)
Averaging Time (min)
0.003 to 1 280 2.19 NA 6
1 to 10 280/f 2.19/f NA 6
10 to 30 28 2.19/f NA 6
30 to 300 28 0.073 2 (above 100 MHz) 6
300 to 1 500 1.585f 0.5 0.0042f 0.5 f / 150 6
1 500 to 15 000 61.4 0.163 10 6
15 000 to 150 000 61.4 0.163 10 616 000/f 1.2
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
4
5.0 Methodology
The RF survey was conducted by G2S staff between January 13 and March 24, 2014. RF measurements were taken with a Narda Broadband Field Meter NBM-550 equipped with a NAR-EC5091 300 kHz - 50 GHz Shaped E-Field Probe, SC6 Canada, Isotropic. This probe ensures that RF exposure is evaluated in the entire frequency band from 300 kHz to 50 GHz, which includes all possible emissions from radio and TV, mobile handhelds (police, emergency services, etc.), cell phone towers and handsets, Bluetooth and Wi-Fi hot spots and devices, etc.
5.1 Preliminary Site Visit
Prior to conducting the EMR survey, G2S visited the twenty-five schools to establish sample locations and identify existing EMR sources within an approximate 250 m radius of each school. The majority of the schools are situated within a residential setting and have similar potential EMR sources including radio, TV broadcast, wireless networks, hydro corridor, cordless phones and mobile devices. Additional EMR sources that were identified during the preliminary site visits are labelled on the site location plans and summarized below.
TABLE 2: ADDITIONAL (NOT WI-FI) ELECTROMAGNETIC SOURCES
School EMR Source Approximate Distance from School (m)
Belfountain P.S Communication Tower On Site
Cawthra S.S. Communication Tower On Site
Central Peel S.S. Multiple Communication Towers 100 - 200
Roof top Cellular Antenna 325
Lorne Park S.S Communication Tower On Site
Meadowvale S.S Roof top Cellular Antenna 250 m Northeast
Port Credit S.S Communication Tower On Site
The additional (not Wi-Fi) Electromagnetic Sources that were identified above are shown on the site location plans provided in Attachments B2, B4, B5, B15, B17 and B22.
5.2 Measurement Equipment
The instrument measures values as percentage of the overall Safety Code 6 MPE limits for which the probe is designed. In this case, the instrument reports the overall detected RF power from 300 kHz to 50 GHz as a percentage of the limits specified by Health Canada Safety Code 6 for controlled environments. Note that this frequency range includes the 2.4 GHz and 5 GHz bands utilized by the PDSB Wi-Fi networks. As a result, a conversion of the measured values is required to assess the measurements against the RF exposure limits set out in Health Canada Safety Code 6 for uncontrolled environments. A comparison between the MPE limits for controlled environments versus uncontrolled environments in the frequency band of the probe (300 kHz to 50 GHz) is given in Table 3. The exposure value reported by the instrument, which is relative to the limits for a controlled
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
5
environment, must be multiplied by a conversion coefficient of 5 in order to obtain the exposure value relative to the limits for an uncontrolled environment. For example, a recorded exposure value of 0.3017% relative to the limits for a controlled environment corresponds to an exposure value of 1.509% relative to the limits for an uncontrolled environment. Note (from Table 3) that the conversion coefficient is 4.6 below 100 MHz frequency, which means that applying a coefficient of 5 results in a slight overestimation of the exposure value relative to the limits for the uncontrolled environment (if radiation below 100 MHz frequency is indeed present). A slight overestimation of the emissions is in fact preferable as it provides an additional, albeit small, safety margin.
TABLE 3: COMPARISON OF THE MPE LIMITS FOR CONTROLLED ENVIRONMENT VERSUS UNCONTROLLED
ENVIRONMENT IN HEALTH CANADA SAFETY CODE 6
Frequency range SC6 limit (controlled)
SC6 limit (uncontrolled) Limit type Power Ratio
0.003 MHz to 1 MHz 600 280 Electric field strength in V/m 4.6
1 MHz to 10 MHz 600/f 280/f Electric field strength in V/m 4.6
10 MHz to 30 MHz 60 28 Electric field strength in V/m 4.6
30 MHz to 100 MHz 60 28 Electric field strength in V/m 4.6
100 MHz to 300 MHz 10 2 Power density in W/m2 5.0
300 MHz to 1.5 GHz f/30 f/150 Power density in W/m2 5.0
1.5 GHz to 3.0 GHz 50 10 Power density in W/m2 5.0
3.0 GHz to 50.0 GHz 50 10 Power density in W/m2 5.0 Note: f denotes frequency in MHz.
At each survey location, a maximum, a minimum and a spatial average measurement was recorded. Note that the time required to survey each location is at least 6 minutes as required by the time-averaging interval of Safety Code 6 (see Table 1). Thus, the spatial average measurement is an average of all values recorded over a 6 minute period and over a volume of space of roughly 0.35 m width, 0.35 m depth, and 1.25 m height, which is at a reasonable distance (for example, 0.5 m) from the floor. This volume represents roughly the volume of a human body and it is the value that must be used to evaluate the exposure relative to the specified limits. The maximum/minimum measurements represent the highest/lowest values recorded over this 6 minute period and they serve the purpose of identifying where possible hot spots may reside. However, in an uncontrolled environment such as schools and public buildings, due to constant changes in the environment (mostly people moving around), such hot spots change constantly and are highly unpredictable. Here, the minimum and maximum values are reported to simply provide the client with an idea of how dynamic the RF environment is in the measured locations.
Two measurements were taken at each location, one with the Wi-Fi computer network “off” and one with the computer network turn “on”. In addition to Wi-Fi, the instrument has the capability of capturing other sources of EMR such as radio and TV broadcast, cellular towers (base-stations), mobile devices, etc. Thus, a measurement with the Wi-Fi network “off” provides a measure of the “background” radiation while the measurement with the Wi-Fi network “on” provides a measure of the “background” radiation plus the added RF power due to the Wi-Fi nodes. It is not uncommon in an uncontrolled environment to observe lower emission levels with
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
6
the Wi-Fi network “off” as compared to when it is “on”. This is because: (i) the environment changes and (ii) effects of destructive and constructive RF wave interference influence the measurements locally.
During this survey, the Wi-Fi computer network “on” measurements were collected with one laptop and three tablets uploading and downloading simultaneously. The four devices were uploading and downloading in the 2.4 GHz or the 5.0 GHz band. The laptop and tablets were in close proximity of the access point during the Wi-Fi computer network “on” measurements, actual distances are provided in Tables 1 to 25 in Attachments B1 to B25.
Data which included the location, time and frequency were recorded and the measurements were saved in the NBM-550 machine.
5.3 Measurement Locations
The survey locations for each school are shown on the site plans provided in Attachments B1 to B25. Readings were taken at various floors and rooms throughout the twenty-five school buildings to ensure proper representation of the school. The survey locations were chosen based on various factors including type of building construction, room size, room use, and potential exposure scenarios (proximity to access points).
Readings were taken at various height levels; in general, measurements were taken between approximately 0.3 m to 6.0 m from the access points.
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
7
6.0 Data Evaluation
The number of survey locations ranged from 10 to 22 in an elementary school and 25 to 37 in a secondary school.
The overall average of the spatial average readings when the Wi-Fi equipment was turned on compared to when it was turned off at each of the twenty-five schools is summarized in Table 4 below:
TABLE 4: OVERALL AVERAGE OF THE SPATIAL AVERAGE RESULTS WITH THE WI-FI COMPUTER NETWORK “OFF”
AND “ON” BY LOCATION
School Sample Type
Wi-Fi Computer Network Measurement
Difference Operating Off % of SC 6 W/m² % of SC 6 W/m²
Allan Drive M.S. Overall Spatial Average 0.943 % 0.0939 1.003 % 0.0999 -0.060 %
Belfountain P.S. Overall Spatial Average 2.211 % 0.2202 0.263 % 0.0262 1.948 % Castlebrooke S.S. Overall Spatial Average 1.815 % 0.1808 0.673 % 0.0670 1.142 % Cawthra Park S.S Overall Spatial Average 1.297 % 0.1292 0.992 % 0.0988 0.305 % Central Peel S.S Overall Spatial Average 1.799 % 0.1792 1.223 % 0.1218 0.576 % Dorset Drive P.S. Overall Spatial Average 2.579 % 0.2569 1.256 % 0.1251 1.323 % Fallingbrook M.S Overall Spatial Average 1.843 % 0.1836 1.235 % 0.1230 0.608 % Fletcher's Meadow S.S Overall Spatial Average 2.154 % 0.2145 1.777 % 0.1770 0.377 % Glenforest S.S Overall Spatial Average 1.052 % 0.1048 1.312 % 0.1307 -0.260 % Herb Campbell P.S. Overall Spatial Average 1.600 % 0.1594 1.337 % 0.1332 0.263 % Hillcrest M.S. Overall Spatial Average 2.655 % 0.2644 0.783 % 0.0780 1.872 % Humberview S.S Overall Spatial Average 1.368 % 0.1363 0.873 % 0.0870 0.495 % Huttonville P.S. Overall Spatial Average 2.251 % 0.2242 1.374 % 0.1369 0.877 % Kenollie P.S. Overall Spatial Average 1.916 % 0.1908 2.31 % 0.2301 -0.394 % Lorne Park S.S Overall Spatial Average 1.270 % 0.1265 0.961 % 0.0957 0.309 % Lougheed M.S Overall Spatial Average 1.761 % 0.1754 2.933 % 0.2921 -1.172 % Meadowvale S.S Overall Spatial Average 1.504 % 0.1498 1.073 % 0.1069 0.431 % Middlebury P.S. Overall Spatial Average 1.937 % 0.1929 1.770 % 0.1763 0.167 % Mineola P.S. Overall Spatial Average 1.526 % 0.1520 2.429 % 0.2419 -0.903 % Morning Star M.S Overall Spatial Average 1.081 % 0.1077 0.791 % 0.0788 0.290 % North Park S.S Overall Spatial Average 1.316 % 0.1311 1.092 % 0.1088 0.224 % Port Credit S.S Overall Spatial Average 1.682 % 0.1675 0.706 % 0.0703 0.976 % Queen Elizabeth Sr. P.S. Overall Spatial Average 1.836 % 0.1829 0.589 % 0.0587 1.247 % Southfields Village P.S. Overall Spatial Average 0.750 % 0.0747 0.625 % 0.0623 0.125 % William G. Davis Sr. P.S. Overall Spatial Average 0.984 % 0.0980 0.958 % 0.0954 0.026 % Note: Measurements are % of Safety Code 6 limit in an uncontrolled environment
Safety Code 6 Limit = 10 W/m2 (uncontrolled)
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
8
A summary of the maximum spatial average, minimum spatial average and overall spatial average at each of the twenty-five schools is presented in a summary table included in Attachment A. The complete results for each school are presented in summary tables included in Attachments B1 to B25. Spatial average, maximum and minimum measurements are presented as a percentage of the allowable limits and in W/m2.
The results relative to the Safety Code 6 in a controlled and uncontrolled environment are shown in the summary tables. A summary of the maximum spatial average measurements recorded at each of the twenty-five schools is summarized in Table 5 below.
TABLE 5: MAXIMUM OF THE SPATIAL AVERAGE RESULTS BY LOCATION
School Sample ID Wi-Fi
Computer Network
% of Safety Code 6 Limits (uncontrolled environment)
Power Density (W/m²)
Allan Drive Middle School AD 1 OFF 1.756 % 0.1749 Belfountain Public School BPS 1 ON 3.260 % 0.3247 Castlebrooke Secondary School CB 22 ON 2.742 % 0.2731 Cawthra Park Secondary School CSS 21 OFF 4.745 % 0.4726 Central Peel Secondary School CP 22 OFF 5.750 % 0.5727 Dorset Drive Public School DD 7 ON 3.934 % 0.3918 Fallingbrook Middle School FB 1 ON 5.205 % 0.5274 Fletcher's Meadow Secondary School FM 23 OFF 3.853 % 0.3838 Glenforest Secondary School G 23 OFF 4.815 % 0.4796 Herb Campbell Public School HC 5 OFF 2.937 % 0.2925 Hillcrest Middle School HMS 14 ON 3.506 % 0.3492 Humberview Secondary School HV 19 ON 5.830 % 0.5807 Huttonville Public School HPS 6 OFF 5.410 % 0.5388 Kenollie Public School K7 OFF 3.369 % 0.3356 Lorne Park Secondary School LP 14 OFF 2.972 % 0.2960 Lougheed Middle School L 4 OFF 4.530 % 0.4512 Meadowvale Secondary School MV 34 OFF 4.961 % 0.4941 Middlebury Public School MPS 9 ON 3.467 % 0.3453 Mineola Public School M 13 ON 5.265 % 0.5244 Morning Star Middle School MS 2 ON 4.240 % 0.4223 North Park Secondary School NP 15 OFF 2.573 % 0.2563 Port Credit Secondary School PC 34 ON 2.780 % 0.2769 Queen Elizabeth Sr. Public School QE 7 ON 2.508 % 0.2498 Southfields Village Public School SFV 11 ON 1.704 % 0.1697 William G. Davis Sr. Public School WD 12 OFF 3.010 % 0.2998
Note: Measurements are % of Safety Code 6 limit in an uncontrolled environment Safety Code 6 Limit = 10 W/m2 (uncontrolled)
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
9
7.0 Conclusion and Recommendations
A total of 551 locations were measured at the twenty-five school buildings. All measurements were well below the Safety Code 6 limit of 10 W/m2 (for frequency ranges between 1500 to 15000 MHz). On average, the RF measurements were higher when the Wi-Fi equipment was turned on compared to when it was turned off, which is expected.
Both the background RF levels (Wi-Fi network “off”) and the total RF levels (Wi-Fi network “on”) show values typical for residential areas of relatively low population density. Note that higher population density usually relates to higher RF activity, especially cell towers.
Based on the findings of this survey, the RF measurements in the areas tested are well within the limits set by Health Canada Safety Code 6. The need for further investigations has not been identified at this time.
8.0 Qualifications of the Reviewer
Dr. Natalia K. Nikolova, P.Eng. (ON), is a Professor at McMaster University, Hamilton. She has been a faculty member of the Department of Electrical and Computer Engineering in McMaster University since 1999 where she teaches courses related to electromagnetic fields and waves, antennas, and radio-frequency (RF) and microwave engineering. She supervises a large research team working on projects in microwave and antenna engineering, electromagnetic field theory and computational methods. She has consulted for more than 11 years in the areas of microwave antennas, radar imaging and detection, and electromagnetic high-frequency computer-aided design. She has been working on collaborative projects between McMaster University and industrial partners related to the RF hazard evaluation of mobile devices and radiation sources for the last seven years. Prof. Nikolova is a registered Professional Engineer in the province of Ontario and a Fellow of the Institute of Electrical and Electronic Engineers (IEEE).
9.0 References
a) Health Canada. Environmental Workplace and Health: Radiofrequency Fields. Updated 2009-11-12. <http://www.hc-sc.gc.ca/ewh-semt/radiation/cons/radiofreq/index-eng.php>.
b) Health Canada. Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 kHz to 300 GHz” (Safety Code 6). 2009.
c) Industry Canada. Case Study: Measurements of Radio Frequency Exposure from Wi-Fi Devices. May 2012.
d) Occupational Health and Safety Act - Ministry of Labour (MOL).
Electromagnetic Radiation (EMR) Testing G2S13160 Twenty-Five Schools, Peel District School Board 26/05/2014
10
10.0 Limitations
This report has been prepared for the sole benefit of the Peel District School Board and is intended to provide a Radiofrequency Electromagnetic Field Survey of the twenty-five school properties. The report may not be used by any other person or entity without the expressed written consent of the Peel District School Board and G2S Environmental Consulting Inc. (G2S). Any use which a third party makes of this report, or any reliance on decisions made based on it, is the responsibility of such third parties. G2S accepts no responsibility for damages, if any suffered by any third party as a result of decisions made or actions based on this report.
The findings in this report are limited to the conditions at the Site at the time of this investigation (January, February and March 2014) as well as information provided by the Site representatives as reported herein. Conclusions presented in this report should not be construed as legal advice.
If Site conditions or applicable standards change or if any additional information becomes available at a future date, changes to the findings, conclusions and recommendations in this report may be necessary.
11.0 Closing Remarks
We trust this report is satisfactory for your purposes. Should you have any questions, please do not hesitate to contact this office.
Yours truly,
Geoff Bell, P. Geo. (limited) Senior Project Manager
Dr. N.K. Nikolova, Fellow IEEE, P.Eng. Electrical Engineer
G2S Environmental Consulting McMaster University
Attachment A Summary Table
Electromagnetic Radiation (EMR) TestingPeel District School Board
SUMMARY TABLE:MAXIMUM, MINIMUM AND AVERAGE
OF THE SPATIAL AVERAGE RESULTS BY LOCATION
G2S13600
ID Power Density % SC6 ID Power
Density % SC6 Power Density % SC6
ON AD 3 0.0197 0.1975% AD 7 0.1704 1.711% 0.094 0.943%
OFF AD 6 0.0050 0.0500% AD 1 0.1749 1.756% 0.100 1.003%
ON BPS 2 0.1497 1.5030% BPS 1 0.3247 3.260% 0.220 2.211%
OFF BPS 2 0.0054 0.0545% BPS 4 0.0505 0.507% 0.026 0.263%
ON CB 1 0.0794 0.7975% CB 21 0.2895 2.907% 0.181 1.815%
OFF CB 26 0.0047 0.0475% CB 5 0.1570 1.577% 0.067 0.673%
ON CSS 1 0.0059 0.0595% CSS 21 0.3556 3.570% 0.129 1.297%
OFF CSS 1 0.0056 0.0560% CSS 21 0.4726 4.745% 0.099 0.992%
ON CP 35 0.0113 0.1130% CP 24 0.3725 3.740% 0.179 1.799%
OFF CP 12 0.0187 0.1850% CP 22 0.5727 5.750% 0.122 1.223%
ON DD 9 0.0470 0.4715% DD 7 0.3918 3.934% 0.257 2.579%
OFF DD 3 0.0382 0.3840% DD 7 0.1992 2.005% 0.125 1.256%
ON FB 4 0.0017 0.0170% FB 1 0.5184 5.205% 0.184 1.843%
OFF FB4 0.0088 0.0885% FB 1 0.3428 3.442% 0.123 1.235%
ON FM 1 0.0551 0.5530% FM 2 0.3869 3.885% 0.215 2.154%
OFF FM 2 0.0033 0.0335% FM 23 0.3525 3.837% 0.177 1.777%
ON G 24 0.0017 0.0175% G 35 0.3667 3.682% 0.105 1.052%
OFF G 4 0.0253 0.2540% G 23 0.4795 4.815% 0.131 1.312%
ON HC 2 0.0323 0.3245% HC 15 0.2555 2.565% 0.159 1.600%
OFF HC 3 0.0294 0.2950% HC 5 0.2925 2.937% 0.133 1.337%
ON HMS 3 0.1446 1.4515% HMS 14 0.3491 3.506% 0.264 2.655%
OFF HMS 3 0.0091 0.0915% HMS 15 0.3256 3.270% 0.078 0.783%
ON HV 12 0.0168 0.1690% HV 19 0.5807 5.830% 0.136 1.368%
OFF HV 18 0.0097 0.0970% HV 27 0.1987 1.986% 0.087 0.873%
ON HPS 2 0.1324 1.3290% HPS 1 0.3252 3.265% 0.224 2.251%
OFF HPS 2 0.0383 0.3845% HPS 6 0.5388 5.410% 0.137 1.374%
ON K 1 0.1017 1.0210% K 7 0.3145 3.158% 0.191 1.916%
OFF K10 0.0783 0.7860% K7 0.3355 3.369% 0.230 2.310%
ON LP 13 0.0026 0.0265% LP 14 0.2843 2.854% 0.126 1.270%
OFF LP 25 0.0233 0.2340% LP 14 0.296 2.972% 0.096 0.961%
ON L1 0.0177 0.1775% L 19 0.4034 4.050% 0.175 1.761%
OFF L 20 0.1176 1.1810% L 4 0.4152 4.530% 0.292 2.933%
ON MV13 0.0035 0.0355% MV 35 0.4576 4.594% 0.150 1.504%
OFF MV 20 0.0036 0.0360% MV 34 0.4941 4.961% 0.107 1.073%
ON MPS 4 0.0992 0.9955% MPS 9 0.3453 3.467% 0.193 1.937%
OFF MPS 4 0.0562 0.5640% MPS 9 0.1993 2.002% 0.176 1.770%
ON M 5 0.0869 0.8725% M 13 0.5244 5.265% 0.152 1.526%
OFF M 10 0.1420 1.4270% M 11 0.4386 4.404% 0.242 2.429%
ON MS 16 0.0073 0.0735% MS 2 0.4223 4.240% 0.108 1.081%
OFF MS 18 0.0071 0.0710% MS 14 0.1909 1.917% 0.079 0.791%
ON NP 13 0.0120 0.1200% NP 29 0.2503 2.514% 0.131 1.316%
OFF NP 25 0.0145 0.1455% NP 15 0.2562 2.573% 0.109 1.092%
ON PC 35 0.0293 0.2945% PC 34 0.2768 2.780% 0.168 1.682%
OFF PC 2 0.0056 0.0560% PC 21 0.1944 1.952% 0.070 0.706%
ON QE 5 0.1054 1.0580% QE 7 0.2497 2.508% 0.183 1.836%
OFF QE 1 0.0046 0.0460% QE 4 0.1559 1.565% 0.059 0.589%
ON SFV 12 0.0063 0.0635% SFV 11 0.1697 1.704% 0.075 0.750%
OFF SFV 14 0.0009 0.0090% SFV 11 0.1596 1.602% 0.062 0.625%
ON WD 9 0.0130 0.1305% WD 8 0.1844 1.852% 0.098 0.984%
OFF WD 2 0.0051 0.0515% WD 12 0.2998 3.010% 0.095 0.958%
Note:Wi-Fi – Wi-Fi Computer Network
ID – Sample IDPower Density Units- W/m²
Safety Code 6 Limit = 10 W/m2 (uncontrolled)
SA – Spatial Average
Overall
Spatial Average
Hillcrest M.S.
Allan Drive M.S.
Wi-fi Network Status
Belfountain P.S.
Castlebrooke S.S.
Cawthra Park S.S.
Central Peel S.S.
School
Dorset Drive P.S.
Fallingbrook M.S.
Measurements are % of Safety Code 6 limits in an uncontrolled environment
Maximum
Spatial Average
Minimum
Spatial Average
Humberview S.S.
William G. Davis Sr. P.S.
Huttonville P.S.
Kenollie P.S.
Lorne Park S.S.
Lougheed M.S.
Meadowvale S.S.
Middlebury P.S.
Port Credit S.S.
Queen Elizabeth Sr. P.S.
Southfields Village P.S.
Mineola P.S.
Morning Star M.S.
North Park S.S.
Fletcher's Meadow S.S.
Glenforest S.S.
Herb Campbell P.S.
Attachment B1 Allan Drive M.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 1: Field Measurements Allan Drive Middle School
Page 1
January 23, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3017 1.5085 0.1502Max 0.7397 3.6985 0.3684Min 0.0000 0.0000 0.0000SA 0.3512 1.7560 0.1749Max 1.2630 6.3150 0.6290Min 0.0000 0.0000 0.0000SA 0.1120 0.5600 0.0558Max 0.3909 1.9545 0.1947Min 0.0000 0.0000 0.0000SA 0.3511 1.7555 0.1748Max 0.6684 3.3420 0.3329Min 0.0730 0.3650 0.0364SA 0.0395 0.1975 0.0197Max 0.3020 1.5100 0.1504Min 0.0000 0.0000 0.0000SA 0.1202 0.6010 0.0599Max 0.8193 4.0965 0.4080Min 0.0000 0.0000 0.0000SA 0.1160 0.5800 0.0578Max 0.3035 1.5175 0.1511Min 0.0000 0.0000 0.0000SA 0.1251 0.6255 0.0623Max 0.3009 1.5045 0.1498Min 0.0092 0.0460 0.0046SA 0.1638 0.8190 0.0816Max 0.3824 1.9120 0.1904Min 0.0000 0.0000 0.0000SA 0.0840 0.4200 0.0418Max 0.8447 4.2235 0.4207Min 0.0000 0.0000 0.0000SA 0.1758 0.8790 0.0875Max 1.1460 5.7300 0.5707Min 0.0000 0.0000 0.0000SA 0.0100 0.0500 0.0050Max 0.1098 0.5490 0.0547Min 0.0000 0.0000 0.0000SA 0.3421 1.7105 0.1704Max 0.5274 2.6370 0.2626Min 0.5274 2.6370 0.2626SA 0.1758 0.8790 0.0875Max 0.5391 2.6955 0.2685Min 0.0000 0.0000 0.0000SA 0.3085 1.5425 0.1536Max 0.5422 2.7110 0.2700Min 0.0059 0.0295 0.0029SA 0.2505 1.2525 0.1247Max 0.4786 2.3930 0.2383Min 0.0000 0.0000 0.0000SA 0.2002 1.0010 0.0997Max 0.5348 2.6740 0.2663Min 0.0000 0.0000 0.0000SA 0.1331 0.6655 0.0663Max 0.5353 2.6765 0.2666Min 0.0000 0.0000 0.0000SA 0.3033 1.5165 0.1510Max 0.8033 4.0165 0.4000Min 0.0293 0.1465 0.0146SA 0.2217 1.1085 0.1104Max 0.5981 2.9905 0.2979Min 0.0000 0.0000 0.0000SA 0.0484 0.2420 0.0241Max 0.4799 2.3995 0.2390Min 0.0000 0.0000 0.0000SA 0.1667 0.8335 0.0830Max 0.6190 3.0950 0.3083Min 0.0000 0.0000 0.0000SA 0.1517 0.7585 0.0755Max 0.4039 2.0195 0.2011Min 0.0000 0.0000 0.0000SA 0.2858 1.4290 0.1423Max 0.6920 3.4600 0.3446Min 0.0351 0.1755 0.0175SA 0.0717 0.3585 0.0357Max 0.6735 3.3675 0.3354Min 0.0000 0.0000 0.0000SA 0.2332 1.1660 0.1161Max 0.8631 4.3155 0.4298Min 0.0059 0.2950 0.0294
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
AD 13 Portable 0.6-1.5 14:10 OFF
AD 12 Room 172 0.9-1.8 15:52 OFF
AD 13 Portable 0.6-1.5 14:02 ON
AD 11 Hallway outside 174
0.9-1.8 15:44 OFF
AD 12 Room 172 0.9-1.8 13:45 ON
AD 11 Hallway outside 174
0.9-1.8 13:37 ON
AD 10 Room 144 0.9-1.8 13:19 ON
AD 10 Room 144 0.9-1.8 15:42 ON
AD 9Hallway outside
custodial storage room
0.9-1.8 13:10 ON
AD 9Hallway outside
custodial storage room
0.9-1.8 15:34 OFF
AD 8 Room 117 0.9-1.8 13:00 ON
AD 8 Room 117 0.9-1.8 15:26 OFF
AD 7 Room 112 0.9-1.8 12:45 ON
AD 7 Room 112 0.9-1.8 15:12 OFF
AD 5 Room 213 0.9-1.8 12:21 ON
AD 6 Staff Room 2.0-4.0 15:04 OFF
AD 5 Room 213 0.9-1.8 16:42 OFF
AD 6 Staff Room 2.0-4.0 12:42 ON
AD 4 Room 223 0.9-1.8 12:09 ON
AD 4 Room 223 0.9-1.8 16:24 OFF
AD 3 Room 215 0.9-1.8 12:00 ON
AD 3 Room 215 0.9-1.8 16:33 OFF
AD 2 Library 0.9-1.8 11:48 ON
AD 2 Library 0.9-1.8 16:50 OFF
AD 1 Room 204 0.9-1.8 11:36 ON
AD 1 Room 204 0.9-1.8 16:58 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 1: Field Measurements Allan Drive Middle School
Page 2
January 23, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2872 1.4360 0.1430Max 0.6810 3.4050 0.3391Min 0.0000 0.0000 0.0000SA 0.2242 1.1210 0.1117Max 0.8789 4.3945 0.4377Min 0.0000 0.0000 0.0000SA 0.2079 1.0395 0.1035Max 0.3918 1.9590 0.1951Min 0.0412 0.2060 0.0205SA 0.2760 1.3800 0.1374Max 0.7933 3.9665 0.3951Min 0.0137 0.0685 0.0068
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
AD 15 Guidance Office 0.9-1.8 15:59 OFF
AD 14 General Office 2.0-4.0 16:07 OFF
AD 15 Guidance Office 0.9-1.8 14:37 ON
AD 14 General Office 2.0-4.0 14:30 ON
Attachment B2 Belfountain P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 2: Field Measurements Belfountain Public School
Page 1
February 20, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.6520 3.2600 0.3247Max 0.9833 4.9165 0.4897Min 0.2049 1.0245 0.1020SA 0.0218 0.1090 0.0109
Max 0.4176 2.0880 0.2080Min 0.0000 0.0000 0.0000SA 0.3006 1.5030 0.1497
Max 0.5697 2.8485 0.2837Min 0.0761 0.3805 0.0379SA 0.0109 0.0545 0.0054
Max 0.2107 1.0535 0.1049Min 0.0000 0.0000 0.0000SA 0.3739 1.8695 0.1862
Max 0.7109 3.5545 0.3540Min 0.0549 0.2745 0.0273SA 0.0866 0.4330 0.0431
Max 0.3262 1.6310 0.1624Min 0.0000 0.0000 0.0000SA 0.4231 2.1155 0.2107
Max 0.6325 3.1625 0.3150Min 0.1402 0.7010 0.0698SA 0.1014 0.5070 0.0505
Max 0.4156 2.0780 0.2070Min 0.0000 0.0000 0.0000SA 0.5949 2.9745 0.2963
Max 0.8361 4.1805 0.4164Min 0.0000 0.0000 0.0000SA 0.0398 0.1990 0.0198
Max 0.2166 1.0830 0.1079Min 0.0000 0.0000 0.0000SA 0.4078 2.0390 0.2031
Max 0.6350 3.1750 0.3162Min 0.2152 1.0760 0.1072SA 0.0662 0.3310 0.0330
Max 0.4163 2.0815 0.2073Min 0.0000 0.0000 0.0000SA 0.4787 2.3935 0.2384
Max 0.7287 3.6435 0.3629Min 0.2106 1.0530 0.1049SA 0.1003 0.5015 0.0499
Max 0.4405 2.2025 0.2194Min 0.0000 0.0000 0.0000SA 0.3949 1.9745 0.1967
Max 1.0360 5.1800 0.5159Min 0.0000 0.0000 0.0000SA 0.0214 0.1070 0.0107
Max 0.4565 2.2825 0.2273Min 0.0000 0.0000 0.0000SA 0.4519 2.2595 0.2250
Max 0.8580 4.2900 0.4273Min 0.2785 1.3925 0.1387SA 0.0442 0.2210 0.0220
Max 0.3371 1.6855 0.1679Min 0.0000 0.0000 0.0000SA 0.3441 1.7205 0.1714
Max 0.6887 3.4435 0.3430Min 0.1923 0.9615 0.0958SA 0.0336 0.1680 0.0167
Max 0.5056 2.5280 0.2518Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
BPS 9 Hallway 0.9-1.5 13:32 ON
BPS 10 Room 7 3.0-5.0 16:44 OFF
BPS 9 Hallway 0.9-1.5 16:37 OFF
BPS 10 Room 7 3.0-5.0 13:39 ON
BPS 8 Room 5 3.0-5.0 13:24 ON
BPS 8 Room 5 3.0-5.0 16:30 OFF
BPS 7 Room 9 3.0-5.0 13:16 ON
BPS 7 Room 9 3.0-5.0 16:23 OFF
BPS 6 Hallway 0.9-1.5 13:09 ON
BPS 6 Hallway 0.9-1.5 16:16 OFF
BPS 5 Library 1-1.5 13:01 ON
BPS 5 Library 1-1.5 16:09 OFF
BPS 4 Room 2 4.0-6.0 12:53 ON
BPS 4 Room 2 4.0-6.0 16:02 OFF
BPS 3 Gym 0.9-1.5 12:44 ON
BPS 3 Gym 0.9-1.5 15:46 OFF
BPS 2 Hallway 1-1.5 12:35 ON
BPS 2 Hallway 1-1.5 15:39 OFF
BPS 1 General Office 3.0-5.0 12:27 ON
BPS 1 General Office 3.0-5.0 15:32 OFF
Attachment B3 Castlebrooke S.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 3: Field Measurements Castlebrook Secondary School
Page 1
March 4-5, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1595 0.7975 0.0794Max 0.4303 2.1515 0.2143Min 0.0000 0.0000 0.0000SA 0.0114 0.0570 0.0057
Max 1.2230 6.1150 0.6091Min 0.0000 0.0000 0.0000SA 0.2739 1.3695 0.1364
Max 1.0240 5.1200 0.5100Min 0.0000 0.0000 0.0000SA 0.1052 0.5260 0.0524
Max 1.0090 5.0450 0.5025Min 0.0000 0.0000 0.0000SA 0.2878 1.4390 0.1433
Max 1.1060 5.5300 0.5508Min 0.0000 0.0000 0.0000SA 0.1241 0.6205 0.0618
Max 1.3040 6.5200 0.6494Min 0.0000 0.0000 0.0000SA 0.3107 1.5535 0.1547
Max 0.9313 4.6565 0.4638Min 0.8700 4.3500 0.4333SA 0.1120 0.5600 0.0558
Max 3.0830 15.4150 1.5353Min 0.0000 0.0000 0.0000SA 0.4470 2.2350 0.2226
Max 0.7745 3.8725 0.3857Min 0.1419 0.7095 0.0707SA 0.3153 1.5765 0.1570
Max 1.5230 7.6150 0.7585Min 0.0000 0.0000 0.0000SA 0.3453 1.7265 0.1720
Max 0.8626 4.3130 0.4296Min 0.0000 0.0000 0.0000SA 0.1394 0.6970 0.0694
Max 0.5310 2.6550 0.2644Min 0.0000 0.0000 0.0000SA 0.5423 2.7115 0.2701
Max 1.0390 5.1950 0.5174Min 0.0458 0.2290 0.0228SA 0.2484 1.2420 0.1237
Max 1.1440 5.7200 0.5697Min 0.0000 0.0000 0.0000SA 0.4168 2.0840 0.2076
Max 0.8783 4.3915 0.4374Min 0.0732 0.3660 0.0365SA 0.1210 0.6050 0.0603
Max 0.7526 3.7630 0.3748Min 0.0000 0.0000 0.0000SA 0.4359 2.1795 0.2171
Max 1.5600 7.8000 0.7769Min 0.0229 0.1145 0.0114SA 0.2662 1.3310 0.1326
Max 2.7840 13.9200 1.3864Min 0.0000 0.0000 0.0000SA 0.4066 2.0330 0.2025
Max 2.5090 12.5450 1.2495Min 0.0870 0.4350 0.0433SA 0.2090 1.0450 0.1041
Max 1.8480 9.2400 0.9203Min 0.0000 0.0000 0.0000SA 0.4573 2.2865 0.2277
Max 3.0780 15.3900 1.5328Min 0.0000 0.0000 0.0000SA 0.0593 0.2965 0.0295
Max 1.9780 9.8900 0.9850Min 0.0000 0.0000 0.0000SA 0.4693 2.3465 0.2337
Max 2.5750 12.8750 1.2824Min 0.0000 0.0000 0.0000SA 0.0658 0.3290 0.0328
Max 1.0900 5.4500 0.5428Min 0.0000 0.0000 0.0000SA 0.4914 2.4570 0.2447
Max 0.9834 4.9170 0.4897Min 0.0275 0.1375 0.0137SA 0.0365 0.1825 0.0182
Max 1.4980 7.4900 0.7460Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
OFF
CB 13 Hall outside 117 0.6-1.5 13:04 ON
CB 13 Hall outside 117 0.6-1.5 17:19 OFF
CB 11 Staff Lounge 2.0-4.0 12:44 ON
CB 11 Staff Lounge 2.0-4.0 17:02 OFF
CB 12 Room 115 2.0-4.0 12:52 ON
CB 12 Room 115 2.0-4.0 17:11
CB 9 Room 110 2.0-4.0 12:29 ON
CB 10 Hall outside 110 0.6-1.5 16:43 OFF
CB 9 Room 110 2.0-4.0 16:53 OFF
CB 10 Hall outside 110 0.6-1.5 12:36 ON
CB 8 Room 106 2.0-4.0 12:20 ON
CB 8 Room 106 2.0-4.0 16:26 OFF
CB 7 Room 102 3.0-5.0 12:12 ON
CB 7 Room 102 3.0-5.0 16:18 OFF
CB 6 Corridor near 102 0.6-1.5 12:04 ON
CB 6 Corridor near 102 0.6-1.5 16:10 OFF
CB 5 Tech/Resource Room 0.9-1.8 11:55 ON
CB 5 Tech/Resource Room 0.9-1.8 18:03 OFF
CB 4 Main Office 0.6-1.5 11:44 ON
CB 4 Main Office 0.6-1.5 17:54 OFF
CB 3 Student Services 3.0-5.0 11:37 ON
CB 3 Student Services 3.0-5.0 15:42 OFF
CB 2 Commons 0.9-1.8 11:29 ON
CB 2 Commons 0.9-1.8 15:35 OFF
CB 1 Cafeteria 1.5-2.4 11:22 ON
CB 1 Cafeteria 1.5-2.4 15:27 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 3: Field Measurements Castlebrook Secondary School
Page 2
March 4-5, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.4388 2.1940 0.2185
Max 0.8778 4.3890 0.4371Min 0.0870 0.4350 0.0433SA 0.0460 0.2300 0.0229
Max 2.1380 10.6900 1.0647Min 0.0000 0.0000 0.0000SA 0.5376 2.6880 0.2677
Max 1.2990 6.4950 0.6469Min 0.1394 0.6970 0.0694SA 0.1011 0.5055 0.0503
Max 1.7610 8.8050 0.8770Min 0.0000 0.0000 0.0000SA 0.4349 2.1745 0.2166
Max 0.7870 3.9350 0.3919Min 0.0503 0.2515 0.0250SA 0.0546 0.2730 0.0272
Max 0.9807 4.9035 0.4884Min 0.0000 0.0000 0.0000SA 0.4113 2.0565 0.2048
Max 0.9990 4.9950 0.4975Min 0.0000 0.0000 0.0000SA 0.0497 0.2485 0.0248
Max 2.7590 13.7950 1.3740Min 0.0000 0.0000 0.0000SA 0.5204 2.6020 0.2592
Max 4.1060 20.5300 2.0448Min 0.0000 0.0000 0.0000SA 0.1959 0.9795 0.0976
Max 1.6450 8.2250 0.8192Min 0.0000 0.0000 0.0000SA 0.4828 2.4140 0.2404
Max 1.8850 9.4250 0.9387Min 0.0229 0.1145 0.0114SA 0.1171 0.5855 0.0583
Max 1.3230 6.6150 0.6589Min 0.0000 0.0000 0.0000SA 0.4452 2.2260 0.2217
Max 2.0480 10.2400 1.0199Min 0.0000 0.0000 0.0000SA 0.0588 0.2940 0.0293
Max 1.5830 7.9150 0.7883Min 0.0000 0.0000 0.0000SA 0.5813 2.9065 0.2895
Max 0.9710 4.8550 0.4836Min 0.0000 0.0000 0.0000SA 0.1845 0.9225 0.0919
Max 2.2190 11.0950 1.1051Min 0.0000 0.0000 0.0000SA 0.5484 2.7420 0.2731
Max 1.0810 5.4050 0.5383Min 0.0653 0.3265 0.0325SA 0.2722 1.3610 0.1356
Max 2.7120 13.5600 1.3506Min 0.0000 0.0000 0.0000SA 0.2271 1.1355 0.1131
Max 0.8883 4.4415 0.4424Min 0.0000 0.0000 0.0000SA 0.2929 1.4645 0.1459
Max 0.7448 3.7240 0.3709Min 0.0000 0.0000 0.0000SA 0.1971 0.9855 0.0982
Max 0.9643 4.8215 0.4802Min 0.0000 0.0000 0.0000SA 0.2936 1.4680 0.1462
Max 0.8283 4.1415 0.4125Min 0.0468 0.2340 0.0233SA 0.1856 0.9280 0.0924
Max 0.9147 4.5735 0.4555Min 0.0000 0.0000 0.0000SA 0.1490 0.7450 0.0742
Max 1.1310 5.6550 0.5632Min 0.0000 0.0000 0.0000SA 0.1825 0.9125 0.0909
Max 0.7811 3.9055 0.3890Min 0.0320 0.1600 0.0159SA 0.0095 0.0475 0.0047
Max 0.5778 2.8890 0.2877Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
CB 26 Room 218 2.0-4.0 17:03 OFF
CB 25 Hall outside 223 1.2-2.1 17:35 OFF
CB 26 Room 218 2.0-4.0 12:49 ON
CB 24 Room 226 2.0-4.0 17:28 OFF
CB 25 Hall outside 223 1.2-2.1 12:39 ON
CB 23 Hall across science terrace 0.9-1.8 17:20 OFF
CB 24 Room 226 2.0-4.0 12:32 ON
CB 22 Staff Prep E 3.0-5.0 18:52 OFF
CB 23 Hall across science terrace 0.9-1.8 12:22 ON
CB 21 Room 212 1.2-2.1 18:44 OFF
CB 22 Staff Prep E 3.0-5.0 14:18 ON
CB 19 Hall outside 205 0.6-1-5 13:53 ON
CB 21 Room 212 1.2-2.1 14:10 ON
CB 19 Hall outside 205 0.6-1-5 18:28 OFF
CB 20 Room 205 2.0-4.0 18:36 OFF
CB 18 Room 201 2.0-4.0 13:45 ON
CB 18 Room 201 2.0-4.0 18:13 OFF
CB 17 Room 209 3.0-5.0 13:37 ON
CB 17 Room 209 3.0-5.0 18:21 OFF
CB 16 Hall outside gym 0.6-1.5 13:21 ON
CB 16 Hall outside gym 0.6-1.5 17:46 OFF
CB 15 Room 122 0.9-1.8 14:29 ON
CB 15 Room 122 0.9-1.8 17:36 OFF
CB 14 Room 120 0.9-1.8 13:06 ON
CB 14 Room 120 0.9-1.8 17:27 OFF
CB 20 Room 205 2.0-4.0 14:01 ON
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 3: Field Measurements Castlebrook Secondary School
Page 3
March 4-5, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2738 1.3690 0.1364
Max 1.0260 5.1300 0.5109Min 0.0275 0.1375 0.0137SA 0.2033 1.0165 0.1012
Max 1.9700 9.8500 0.9811Min 0.0000 0.0000 0.0000SA 0.2893 1.4465 0.1441
Max 0.6083 3.0415 0.3029Min 0.0275 0.1375 0.0137SA 0.0182 0.0910 0.0091
Max 0.3236 1.6180 0.1612Min 0.0000 0.0000 0.0000SA 0.2535 1.2675 0.1262
Max 0.7007 3.5035 0.3489Min 0.0000 0.0000 0.0000SA 0.0456 0.2280 0.0227
Max 1.0710 5.3550 0.5334Min 0.0000 0.0000 0.0000SA 0.2583 1.2915 0.1286
Max 2.4180 12.0900 1.2042Min 0.0000 0.0000 0.0000SA 0.1343 0.6715 0.0669
Max 2.5620 12.8100 1.2759Min 0.0000 0.0000 0.0000SA 0.2962 1.4810 0.1475
Max 0.6193 3.0965 0.3084Min 0.1053 0.5265 0.0524SA 0.1587 0.7935 0.0790
Max 1.0170 5.0850 0.5065Min 0.0000 0.0000 0.0000SA 0.2875 1.4375 0.1432
Max 0.7330 3.6650 0.3650Min 0.1053 0.5265 0.0524SA 0.1143 0.5715 0.0569
Max 1.9820 9.9100 0.9870Min 0.0000 0.0000 0.0000SA 0.3042 1.5210 0.1515
Max 0.6162 3.0810 0.3069Min 0.0412 0.2060 0.0205SA 0.1376 0.6880 0.0685
Max 1.5040 7.5200 0.7490Min 0.0000 0.0000 0.0000SA 0.2738 1.3690 0.1364
Max 1.7180 8.5900 0.8556Min 0.0000 0.0000 0.0000SA 0.0715 0.3575 0.0356
Max 0.6755 3.3775 0.3364Min 0.0000 0.0000 0.0000SA 0.2827 1.4135 0.1408
Max 1.2040 6.0200 0.5996Min 0.0000 0.0000 0.0000SA 0.1532 0.7660 0.0763
Max 1.0410 5.2050 0.5184Min 0.0000 0.0000 0.0000SA 0.2636 1.3180 0.1313
Max 0.5104 2.5520 0.2542Min 0.0732 0.3660 0.0365SA 0.1282 0.6410 0.0638
Max 1.1030 5.5150 0.5493Min 0.0000 0.0000 0.0000SA 0.2399 1.1995 0.1195
Max 0.4549 2.2745 0.2265Min 0.0915 0.4575 0.0456SA 0.0999 0.4995 0.0498
Max 0.7038 3.5190 0.3505Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
CB 37 Room 310 2.0-4.0 16:13 OFF
CB 36 Staff Prep H 3.0-5.0 16:21 OFF
CB 37 Room 310 2.0-4.0 14:23 ON
CB 35 Hall outside 302 and 303 0.9-1.8 16:44 OFF
CB 36 Staff Prep H 3.0-5.0 14:16 ON
CB 35 Hall outside 302 and 303 0.9-1.8 14:08 ON
CB 34 Room 305 2.0-4.0 14:01 ON
CB 34 Room 305 2.0-4.0 16:37 OFF
CB 33 Room 308 2.0-4.0 13:53 ON
CB 33 Room 308 2.0-4.0 16:29 OFF
CB 32 Room 319 2.0-4.0 13:41 ON
CB 32 Room 319 2.0-4.0 16:03 OFF
CB 31 Room 314 2.0-4.0 13:33 ON
CB 31 Room 314 2.0-4.0 15:55 OFF
CB 30 Hall outside 314 0.9-1.8 13:26 ON
CB 30 Hall outside 314 0.9-1.8 15:48 OFF
CB 29 Room 311 2.0-4.0 13:18 ON
CB 29 Room 311 2.0-4.0 15:40 OFF
0.9-1.8 13:09 ON
CB 28 Corridor across open to below 0.9-1.8 15:30 OFF
CB 28 Corridor across open to below
CB 27 Room 216 2.0-4.0 17:11 OFF
CB 27 Room 216 2.0-4.0 12:58 ON
Attachment B4 Cawthra Park S.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 4: Field Measurements Cawthra Secondary School
Page 1
February 27-28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.0119 0.0595 0.0059Max 1.3750 6.8750 0.6848Min 0.0000 0.0000 0.0000SA 0.0112 0.0560 0.0056
Max 0.0585 0.2925 0.0291Min 0.0000 0.0000 0.0000SA 0.0561 0.2805 0.0279
Max 0.3712 1.8560 0.1849Min 0.0000 0.0000 0.0000SA 0.0495 0.2475 0.0247
Max 0.3068 1.5340 0.1528Min 0.0000 0.0000 0.0000SA 0.1396 0.6980 0.0695
Max 0.5496 2.7480 0.2737Min 0.0000 0.0000 0.0000SA 0.1402 0.7010 0.0698
Max 0.9381 4.6905 0.4672Min 0.0000 0.0000 0.0000SA 0.1821 0.9105 0.0907
Max 0.3495 1.7475 0.1741Min 0.0183 0.0915 0.0091SA 0.1527 0.7635 0.0760
Max 0.4404 2.2020 0.2193Min 0.0000 0.0000 0.0000SA 0.1404 0.7020 0.0699
Max 0.5386 2.6930 0.2682Min 0.0000 0.0000 0.0000SA 0.1226 0.6130 0.0611
Max 0.5188 2.5940 0.2584Min 0.0000 0.0000 0.0000SA 0.2132 1.0660 0.1062
Max 0.5404 2.7020 0.2691Min 0.0000 0.0000 0.0000SA 0.2930 1.4650 0.1459
Max 0.5335 2.6675 0.2657Min 0.0732 0.3660 0.0365SA 0.3220 1.6100 0.1604
Max 0.7132 3.5660 0.3552Min 0.0046 0.0230 0.0023SA 0.2703 1.3515 0.1346
Max 0.9147 4.5735 0.4555Min 0.0000 0.0000 0.0000SA 0.3337 1.6685 0.1662
Max 0.5340 2.6700 0.2659Min 0.1134 0.5670 0.0565SA 0.2689 1.3445 0.1339
Max 0.8648 4.3240 0.4307Min 0.0000 0.0000 0.0000SA 0.2574 1.2870 0.1282
Max 0.8811 4.4055 0.4388Min 0.0000 0.0000 0.0000SA 0.1599 0.7995 0.0796
Max 0.9504 4.7520 0.4733Min 0.0000 0.0000 0.0000SA 0.2103 1.0515 0.1047
Max 0.4414 2.2070 0.2198Min 0.0366 0.1830 0.0182SA 0.1820 0.9100 0.0906
Max 0.4340 2.1700 0.2161Min 0.0458 0.2290 0.0228SA 0.2577 1.2885 0.1283
Max 0.9422 4.7110 0.4692Min 0.0641 0.3205 0.0319SA 0.2064 1.0320 0.1028
Max 1.6750 8.3750 0.8342Min 0.0000 0.0000 0.0000SA 0.2796 1.3980 0.1392
Max 0.7781 3.8905 0.3875Min 0.0000 0.0000 0.0000SA 0.2508 1.2540 0.1249
Max 0.6862 3.4310 0.3417Min 0.0000 0.0000 0.0000SA 0.3992 1.9960 0.1988
Max 0.6435 3.2175 0.3205Min 0.1190 0.5950 0.0593SA 0.4288 2.1440 0.2135
Max 0.7661 3.8305 0.3815Min 0.1381 0.6905 0.0688
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
CSS 13 Room 308 2.0-4.0 16:42 OFF
CSS 12 Room 301 2.0-4.0 16:34 OFF
CSS 13 Room 308 2.0-4.0 12:42 ON
CSS 11 Library 1-1.5 16:16 OFF
CSS 12 Room 301 2.0-4.0 12:33 ON
CSS 10 Room 217 1-1.5 12:10 ON
CSS 11 Library 1-1.5 12:20 ON
CSS 10 Room 217 1-1.5 16:07 OFF
CSS 9 Room 214 1-1.5 12:01 ON
CSS 9 Room 214 1-1.5 15:59 OFF
CSS 8 Room 210 2.0-4.0 11:53 ON
CSS 8 Room 210 2.0-4.0 15:51 OFF
CSS 7 Hallway 1-1.5 11:46 ON
CSS 7 Hallway 1-1.5 15:45 OFF
CSS 6 Room 207 2.0-4.0 11:38 ON
CSS 6 Room 207 2.0-4.0 16:25 OFF
CSS 5 Social Science (2nd floor)
2.0-4.0 11:30 ON
CSS 5 Social Science (2nd floor)
2.0-4.0 15:37 OFF
CSS 4 Hallway outside room 203
0.6-1.2 11:22 ON
CSS 4 Hallway outside room 203
0.6-1.2 15:29 OFF
CSS 3 Staff Room 0.6-1.2 11:14 ON
CSS 3 Staff Room 0.6-1.2 15:21 OFF
CSS 2 Guidance Office 0.6-1.2 11:06 ON
CSS 2 Guidance Office 0.6-1.2 15:13 OFF
CSS 1 General Office 0.6-1.2 10:59 ON
CSS 1 General Office 0.6-1.2 15:06 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 4: Field Measurements Cawthra Secondary School
Page 2
February 27-28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3988 1.9940 0.1986
Max 0.7814 3.9070 0.3891Min 0.1411 0.7055 0.0703SA 0.2625 1.3125 0.1307
Max 0.5585 2.7925 0.2781Min 0.0824 0.4120 0.0410SA 0.2193 1.0965 0.1092
Max 0.4406 2.2030 0.2194Min 0.0915 0.4575 0.0456SA 0.1796 0.8980 0.0894
Max 0.3836 1.9180 0.1910Min 0.0595 0.2975 0.0296SA 0.2394 1.1970 0.1192
Max 0.9160 4.5800 0.4562Min 0.0000 0.0000 0.0000SA 0.1762 0.8810 0.0877
Max 0.7844 3.9220 0.3906Min 0.0000 0.0000 0.0000SA 0.1753 0.8765 0.0873
Max 0.4277 2.1385 0.2130Min 0.0367 0.1833 0.0183SA 0.1402 0.7010 0.0698
Max 0.4126 2.0630 0.2055Min 0.0183 0.0915 0.0091SA 0.3583 1.7915 0.1784
Max 0.8704 4.3520 0.4335Min 0.0059 0.0295 0.0029SA 0.4391 2.1955 0.2187
Max 0.9124 4.5620 0.4544Min 0.0687 0.3435 0.0342SA 0.3074 1.5370 0.1531
Max 0.7065 3.5325 0.3518Min 0.0137 0.0685 0.0068SA 0.3074 1.5370 0.1531
Max 0.8203 4.1015 0.4085Min 0.0000 0.0000 0.0000SA 0.4319 2.1595 0.2151
Max 1.2290 6.1450 0.6120Min 0.0137 0.0685 0.0068SA 0.3325 1.6625 0.1656
Max 1.3650 6.8250 0.6798Min 0.0000 0.0000 0.0000SA 0.7140 3.5700 0.3556
Max 1.4810 7.4050 0.7375Min 0.0000 0.0000 0.0000SA 0.9490 4.7450 0.4726
Max 1.6010 8.0050 0.7973Min 0.0092 0.0460 0.0046SA 0.0206 0.1030 0.0103
Max 0.9552 4.7760 0.4757Min 0.0000 0.0000 0.0000SA 0.0289 0.1445 0.0144
Max 0.4165 2.0825 0.2074Min 0.0000 0.0000 0.0000SA 0.1113 0.5565 0.0554
Max 0.8096 4.0480 0.4032Min 0.0000 0.0000 0.0000SA 0.0273 0.1365 0.0136
Max 0.6962 3.4810 0.3467Min 0.0000 0.0000 0.0000SA 0.3409 1.7045 0.1698
Max 0.6664 3.3320 0.3319Min 0.0000 0.0000 0.0000SA 0.1591 0.7955 0.0792
Max 0.5592 2.7960 0.2785Min 0.0000 0.0000 0.0000SA 0.1568 0.7840 0.0781
Max 0.4493 2.2465 0.2238Min 0.0000 0.0000 0.0000SA 0.0331 0.1655 0.0165
Max 0.5780 2.8900 0.2878Min 0.0000 0.0000 0.0000SA 0.2196 1.0980 0.1094
Max 0.5717 2.8585 0.2847Min 0.0000 0.0000 0.0000SA 0.1147 0.5735 0.0571
Max 0.6401 3.2005 0.3188Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
CSS 26 Room 105B 0.8-1.5 15:44 OFF
CSS 25 Room 105A 0.6-1.2 15:37 OFF
CSS 26 Room 105B 0.8-1.5 13:02 ON
CSS 24 Room 100 0.6-1.2 15:29 OFF
CSS 25 Room 105A 0.6-1.2 12:54 ON
CSS 23 Gym 1.5-2 15:12 OFF
CSS 24 Room 100 0.6-1.2 12:46 ON
CSS 22 Hallway outside room 110
0.6-1.2 15:20 OFF
CSS 23 Gym 1.5-2 12:37 ON
CSS 21 Portable 2 0.3-0.9 18:02 OFF
CSS 22 Hallway outside room 110
0.6-1.2 12:28 ON
CSS 21 Portable 2 0.3-0.9 14:02 ON
CSS 20 Portable 4 0.3-0.9 17:49 OFF
CSS 19 Room 311 1-1.5 17:29 OFF
CSS 20 Portable 4 0.3-0.9 13:50 ON
CSS 18 Work Room (3rd floor)
2.0-4.0 17:22 OFF
CSS 19 Room 311 1-1.5 13:33 ON
CSS 17 Hallway outside room 315
0.6-1.2 17:13 OFF
CSS 18 Work Room (3rd floor)
2.0-4.0 13:25 ON
CSS 16 Room 317 1-1.5 17:05 OFF
CSS 17 Hallway outside room 315
0.6-1.2 13:17 ON
CSS 15 Hallway outside room 314
0.6-1.2 16:58 OFF
CSS 16 Room 317 1-1.5 13:10 ON
CSS 14 Room 305 2.0-4.0 16:50 OFF
CSS 15 Hallway outside room 314
0.6-1.2 13:02 ON
CSS 14 Room 305 2.0-4.0 12:49 ON
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 4: Field Measurements Cawthra Secondary School
Page 3
February 27-28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1660 0.8300 0.0827
Max 0.6104 3.0520 0.3040Min 0.0000 0.0000 0.0000SA 0.0312 0.1560 0.0155
Max 0.5417 2.7085 0.2698Min 0.0000 0.0000 0.0000SA 0.1988 0.9940 0.0990
Max 0.7720 3.8600 0.3845Min 0.0000 0.0000 0.0000SA 0.0976 0.4880 0.0486
Max 0.7234 3.6170 0.3603Min 0.0000 0.0000 0.0000SA 0.1431 0.7155 0.0713
Max 0.4442 2.2210 0.2212Min 0.0092 0.0460 0.0046SA 0.0498 0.2490 0.0248
Max 0.8801 4.4005 0.4383Min 0.0000 0.0000 0.0000SA 0.3399 1.6995 0.1693
Max 0.8409 4.2045 0.4188Min 0.0000 0.0000 0.0000SA 0.1139 0.5695 0.0567
Max 0.3892 1.9460 0.1938Min 0.0000 0.0000 0.0000SA 0.2831 1.4155 0.1410
Max 0.9554 4.7770 0.4758Min 0.0000 0.0000 0.0000SA 0.1446 0.7230 0.0720
Max 0.9603 4.8015 0.4782Min 0.0000 0.0000 0.0000SA 0.2983 1.4915 0.1486
Max 1.4660 7.3300 0.7301Min 0.0000 0.0000 0.0000SA 0.1181 0.5905 0.0588
Max 0.4885 2.4425 0.2433Min 0.0000 0.0000 0.0000SA 0.4181 2.0905 0.2082
Max 3.1400 15.7000 1.5637Min 0.0000 0.0000 0.0000SA 0.2844 1.4220 0.1416
Max 0.9413 4.7065 0.4688Min 0.0000 0.0000 0.0000SA 0.4779 2.3895 0.2380
Max 0.8491 4.2455 0.4229Min 0.0789 0.3945 0.0393SA 0.2233 1.1165 0.1112
Max 0.8514 4.2570 0.4240Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
ON
CSS 30 Hallway outside room 113
0.6-1.2 16:30 OFF
CSS 29 Auditorium 1.2-1.8 16:07 OFF
CSS 30 Hallway outside room 113
0.6-1.2 13:35 ON
CSS 34 Room 111 2.0-4.0 16:45 OFF
CSS 33 Room 107 2.0-4.0 16:15 OFF
CSS 34 Room 111 2.0-4.0 14:12 ON
CSS 32 Café 1-1.5 16:23 OFF
CSS 33 Room 107 2.0-4.0 14:02 ON
CSS 31 Room 112 2.0-4.0 16:37 OFF
CSS 32 Café 1-1.5 13:51 ON
CSS 31 Room 112 2.0-4.0 13:42 ON
CSS 27 Hallway outside room 114
0.6-1.2 15:52 OFF
CSS 28 Room 114 2.0-4.0 15:59 OFF
CSS 29 Auditorium 1.2-1.8 13:26 ON
CSS 28 Room 114 2.0-4.0 13:18
CSS 27 Hallway outside room 114
0.6-1.2 13:10 ON
Attachment B5 Central Peel S.S.
EMR TestingPeel District School Board
Table 5: Field Measurements Central Peel Secondary School
Page 1
February 27-28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.4246 2.1230 0.2115Max 1.7850 8.9250 0.8889Min 0.0000 0.0000 0.0000SA 0.0496 0.2480 0.0247
Max 1.4700 7.3500 0.7321Min 0.0000 0.0000 0.0000SA 0.1771 0.8855 0.0882
Max 1.0330 5.1650 0.5144Min 0.0000 0.0000 0.0000SA 0.0854 0.4270 0.0425
Max 1.3920 6.9600 0.6932Min 0.0000 0.0000 0.0000SA 0.4674 2.3370 0.2328
Max 0.6839 3.4195 0.3406Min 0.1288 0.6440 0.0641SA 0.1854 0.9270 0.0923
Max 0.4682 2.3410 0.2332Min 0.0000 0.0000 0.0000SA 0.4202 2.1010 0.2093
Max 0.8313 4.1565 0.4140Min 0.1274 0.6370 0.0634SA 0.0738 0.3690 0.0368
Max 0.5875 2.9375 0.2926Min 0.0000 0.0000 0.0000SA 0.3589 1.7945 0.1787
Max 1.6200 8.1000 0.8068Min 0.0000 0.0000 0.0000SA 0.0500 0.2500 0.0249
Max 1.4410 7.2050 0.7176Min 0.0000 0.0000 0.0000SA 0.2972 1.4860 0.1480
Max 0.9157 4.5785 0.4560Min 0.0000 0.0000 0.0000SA 0.0605 0.3025 0.0301
Max 0.9491 4.7455 0.4727Min 0.0000 0.0000 0.0000SA 0.2369 1.1845 0.1180
Max 0.5529 2.7645 0.2753Min 0.0870 0.4350 0.0433SA 0.0415 0.2075 0.0207
Max 0.7040 3.5200 0.3506Min 0.0000 0.0000 0.0000SA 0.3324 1.6620 0.1655
Max 0.7455 3.7275 0.3713Min 0.0687 0.3435 0.0342SA 0.0390 0.1950 0.0194
Max 0.4246 2.1230 0.2115Min 0.0000 0.0000 0.0000SA 0.3718 1.8590 0.1852
Max 1.3490 6.7450 0.6718Min 0.0000 0.0000 0.0000SA 0.0378 0.1890 0.0188
Max 0.3684 1.8420 0.1835Min 0.0000 0.0000 0.0000SA 0.4681 2.3405 0.2331
Max 1.2470 6.2350 0.6210Min 0.1007 0.5035 0.0501SA 0.1330 0.6650 0.0662
Max 1.5210 7.6050 0.7575Min 0.0000 0.0000 0.0000SA 0.4777 2.3885 0.2379
Max 0.9339 4.6695 0.4651Min 0.1366 0.6830 0.0680SA 0.0812 0.4060 0.0404
Max 0.7491 3.7455 0.3731Min 0.0000 0.0000 0.0000SA 0.4543 2.2715 0.2262
Max 1.4990 7.4950 0.7465Min 0.0000 0.0000 0.0000SA 0.0373 0.1865 0.0186
Max 1.6300 8.1500 0.8117Min 0.0000 0.0000 0.0000SA 0.3805 1.9025 0.1895
Max 1.0370 5.1850 0.5164Min 0.1556 0.7780 0.0775SA 0.0745 0.3725 0.0371
Max 1.2540 6.2700 0.6245Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
CP 13 Room 123 0.9-1.8 16:39 OFF
CP 12 Room 118 0.9-1.8 16:30 OFF
CP 13 Room 123 0.9-1.8 12:25 ON
CP 11 Geo. Office (1st Floor)
0.6-1.5 16:23 OFF
CP 12 Room 118 0.9-1.8 12:17 ON
CP 10 Room 119 0.9-1.8 12:00 ON
CP 11 Geo. Office (1st Floor)
0.6-1.5 12:08 ON
CP 10 Room 119 0.9-1.8 16:15 OFF
CP 9 Room 117 0.9-1.8 11:51 ON
CP 9 Room 117 0.9-1.8 16:07 OFF
CP 8 Room 115 0.9-1.8 11:41 ON
CP 8 Room 115 0.9-1.8 15:58 OFF
CP 7 Hall outside 113 0.6-1.5 11:34 ON
CP 7 Hall outside 113 0.6-1.5 15:51 OFF
CP 6 Library 0.6-1.5 11:26 ON
CP 6 Library 0.6-1.5 15:43 OFF
CP 5 Room 109 0.6-1.5 11:18 ON
CP 5 Room 109 0.6-1.5 15:35 OFF
CP 4 Cafeteria 0.3-1.2 11:01 ON
CP 4 Cafeteria 0.3-1.2 15:27 OFF
CP 3 Room 103 N/A 11:01 ON
CP 3 Room 103 N/A 15:13 OFF
CP 2 Guidance (1st Floor)
0.6-1.5 10:52 ON
CP 2 Guidance (1st Floor)
0.6-1.5 14:50 OFF
CP 1 General Office (1st Floor)
3.0-5.0 10:43 ON
CP 1 General Office (1st Floor)
3.0-5.0 14:42 OFF
EMR TestingPeel District School Board
Table 5: Field Measurements Central Peel Secondary School
Page 2
February 27-28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3901 1.9505 0.1943Max 2.7370 13.6850 1.3630Min 0.0000 0.0000 0.0000SA 0.0613 0.3065 0.0305
Max 2.8420 14.2100 1.4153Min 0.0000 0.0000 0.0000SA 0.4008 2.0040 0.1996
Max 1.3690 6.8450 0.6818Min 0.0641 0.3205 0.0319SA 0.1422 0.7110 0.0708
Max 1.0190 5.0950 0.5075Min 0.0000 0.0000 0.0000SA 0.3523 1.7615 0.1754
Max 0.7279 3.6395 0.3625Min 0.1007 0.5035 0.0501SA 0.0495 0.2475 0.0247
Max 1.9900 9.9500 0.9910Min 0.0000 0.0000 0.0000SA 0.4381 2.1905 0.2182
Max 0.8417 4.2085 0.4192Min 0.0687 0.3435 0.0342SA 0.1921 0.9605 0.0957
Max 1.5300 7.6500 0.7619Min 0.0000 0.0000 0.0000SA 0.5010 2.5050 0.2495
Max 0.9855 4.9275 0.4908Min 0.0412 0.2060 0.0205SA 0.3664 1.8320 0.1825
Max 2.2710 11.3550 1.1310Min 0.0000 0.0000 0.0000SA 0.2487 1.2435 0.1239
Max 0.5663 2.8315 0.2820Min 0.1089 0.5445 0.0542SA 0.0606 0.3030 0.0302
Max 1.7340 8.6700 0.8635Min 0.0000 0.0000 0.0000SA 0.0735 0.3675 0.0366
Max 0.6224 3.1120 0.3100Min 0.0000 0.0000 0.0000SA 0.0649 0.3245 0.0323
Max 0.3771 1.8855 0.1878Min 0.0000 0.0000 0.0000SA 0.6273 3.1365 0.3124
Max 2.2380 11.1900 1.1145Min 0.0000 0.0000 0.0000SA 1.0820 5.4100 0.5388
Max 2.3280 11.6400 1.1593Min 0.0000 0.0000 0.0000SA 0.2402 1.2010 0.1196
Max 2.2960 11.4800 1.1434Min 0.0000 0.0000 0.0000SA 1.1500 5.7500 0.5727
Max 2.0590 10.2950 1.0254Min 0.0000 0.0000 0.0000SA 0.3694 1.8470 0.1840
Max 1.3470 6.7350 0.6708Min 0.0000 0.0000 0.0000SA 0.2012 1.0060 0.1002
Max 1.0690 5.3450 0.5324Min 0.0000 0.0000 0.0000SA 0.7480 3.7400 0.3725
Max 1.8440 9.2200 0.9183Min 0.0000 0.0000 0.0000SA 0.3362 1.6810 0.1674
Max 1.2760 6.3800 0.6354Min 0.0000 0.0000 0.0000SA 0.6498 3.2490 0.3236
Max 1.3200 6.6000 0.6574Min 0.0092 0.0460 0.0046SA 0.3898 1.9490 0.1941
Max 1.5530 7.7650 0.7734Min 0.0000 0.0000 0.0000SA 0.1445 0.7225 0.0720
Max 0.7725 3.8625 0.3847Min 0.0000 0.0000 0.0000SA 0.4226 2.1130 0.2105
Max 1.3900 6.9500 0.6922Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
CP 26 Room 206 0.6-1.5 15:39 OFF
CP 25 Room 207 0.6-1.5 15:46 OFF
CP 26 Room 206 0.6-1.5 11:42 ON
CP 24 Portable 1 0.3-1.2 15:04 OFF
CP 25 Room 207 0.6-1.5 11:31 ON
CP 23 Portable 7 0.3-1.2 14:56 OFF
CP 24 Portable 1 0.3-1.2 11:16 ON
CP 22 Annex Teaching Space
0.9-1.8 15:12 OFF
CP 23 Portable 7 0.3-1.2 11:03 ON
CP 21 Annex General Office
0.9-1.8 15:20 OFF
CP 22 Annex Teaching Space
0.9-1.8 10:52 ON
CP 21 Annex General Office
0.9-1.8 10:44 ON
CP 19 Room 134 0.6-1.5 17:12 OFF
CP 20 Room 147 0.3-1.2 17:28
CP 20 Room 147 0.3-1.2 13:56 ON
OFF
CP 18 Gym C 0.3- 1.2 16:47 OFF
CP 19 Room 134 0.6-1.5 13:31 ON
CP 17 Auditorium 2.1-3.0 17:38 OFF
CP 18 Gym C 0.3- 1.2 13:22 ON
CP 16 Hall outside washroom
0.6-1.5 17:20 OFF
CP 17 Auditorium 2.1-3.0 13:08 ON
CP 16 Hall outside washroom
0.6-1.5 12:54 ON
CP 15 Room 131 1.2-2.1 17:03 OFF
CP 14 Tech. Office (1st Floor)
0.9-1.8 16:56 OFF
CP 15 Room 131 1.2-2.1 12:43 ON
CP 14 Tech. Office (1st Floor)
0.9-1.8 12:35 ON
EMR TestingPeel District School Board
Table 5: Field Measurements Central Peel Secondary School
Page 3
February 27-28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3142 1.5710 0.1565Max 0.8071 4.0355 0.4019Min 0.0000 0.0000 0.0000SA 0.6599 3.2995 0.3286
Max 1.7640 8.8200 0.8785Min 0.0000 0.0000 0.0000SA 0.2210 1.1050 0.1101
Max 1.5280 7.6400 0.7609Min 0.0000 0.0000 0.0000SA 0.2270 1.1350 0.1130
Max 1.0820 5.4100 0.5388Min 0.0000 0.0000 0.0000SA 0.2911 1.4555 0.1450
Max 0.7264 3.6320 0.3617Min 0.0412 0.2060 0.0205SA 0.3380 1.6900 0.1683
Max 1.4830 7.4150 0.7385Min 0.0000 0.0000 0.0000SA 0.2633 1.3165 0.1311
Max 0.9644 4.8220 0.4803Min 0.0412 0.2060 0.0205SA 0.3192 1.5960 0.1590
Max 1.5940 7.9700 0.7938Min 0.0000 0.0000 0.0000SA 0.3217 1.6085 0.1602
Max 0.9178 4.5890 0.4571Min 0.0000 0.0000 0.0000SA 0.4453 2.2265 0.2218
Max 3.0820 15.4100 1.5348Min 0.0000 0.0000 0.0000SA 0.4139 2.0695 0.2061
Max 1.2640 6.3200 0.6295Min 0.0137 0.0685 0.0068SA 0.3766 1.8830 0.1875
Max 1.4020 7.0100 0.6982Min 0.1377 0.6885 0.0686SA 0.3329 1.6645 0.1658
Max 1.5170 7.5850 0.7555Min 0.0000 0.0000 0.0000SA 0.3770 1.8850 0.1877
Max 2.7850 13.9250 1.3869Min 0.0000 0.0000 0.0000SA 0.3827 1.9135 0.1906
Max 1.0540 5.2700 0.5249Min 0.0000 0.0000 0.0000SA 0.3486 1.7430 0.1736
Max 3.8340 19.1700 1.9093Min 0.0000 0.0000 0.0000SA 0.0226 0.1130 0.0113
Max 0.3936 1.9680 0.1960Min 0.0000 0.0000 0.0000SA 0.3193 1.5965 0.1590
Max 2.4180 12.0900 1.2042Min 0.0000 0.0000 0.0000SA 0.1012 0.5060 0.0504
Max 0.8644 4.3220 0.4305Min 0.0000 0.0000 0.0000SA 0.4730 2.3650 0.2356
Max 1.9740 9.8700 0.9831Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
CP 36 Room 219 2.0-4.0 16:23 OFF
CP 35 Music Office (1st Floor)
0.9-1.8 16:57 OFF
CP 36 Room 219 2.0-4.0 14:06 ON
CP 34 Hall outside 214 0.6-1.5 12:56 ON
OFF
CP 32 Room 225 0.9-1.8
CP 33 Room 229 0.9-1.8 16:46
12:39 ON
CP 31 Room 222 0.9-1.8 16:31
OFF
CP 32 Room 225 0.9-1.8 16:39
CP 35 Music Office (1st Floor)
0.9-1.8 13:53 ON
CP 34 Hall outside 214 0.6-1.5 16:15 OFF
OFF
CP 33 Room 229 0.9-1.8 12:48 ON
CP 31 Room 222 0.9-1.8 12:31 ON
CP 30 Room 214 0.9-1.8 16:08 OFF
CP 29 Hall outside 210 0.6-1.5 16:01 OFF
CP 30 Room 214 0.9-1.8 12:14 ON
CP 28 Room 211 0.9-1.8 15:54 OFF
CP 29 Hall outside 210 0.6-1.5 12:06 ON
CP 27 Room 203 0.9-1.8 15:31 OFF
CP 28 Room 211 0.9-1.8 11:58 ON
CP 27 Room 203 0.9-1.8 11:50 ON
Attachment B6 Dorset Drive P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 6: Field Measurements Dorset Drive Public School
Page 1
January 30, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.7297 3.6485 0.3634Max 1.2420 6.2100 0.6185Min 0.1116 0.5580 0.0556SA 0.2520 1.2600 0.1255
Max 0.5794 2.8970 0.2885Min 0.0000 0.0000 0.0000SA 0.5041 2.5205 0.2510
Max 0.7366 3.6830 0.3668Min 0.2470 1.2350 0.1230SA 0.2587 1.2935 0.1288
Max 0.5568 2.7840 0.2773Min 0.0000 0.0000 0.0000SA 0.4174 2.0870 0.2079
Max 0.8409 4.2045 0.4188Min 0.1694 0.8470 0.0844SA 0.0768 0.3840 0.0382
Max 0.3124 1.5620 0.1556Min 0.0000 0.0000 0.0000SA 0.6972 3.4860 0.3472
Max 0.9618 4.8090 0.4790Min 0.3434 1.7170 0.1710SA 0.3213 1.6065 0.1600
Max 0.8101 4.0505 0.4034Min 0.0000 0.0000 0.0000SA 0.4778 2.3890 0.2379
Max 0.8226 4.1130 0.4097Min 0.2398 1.1990 0.1194SA 0.2347 1.1735 0.1169
Max 0.8267 4.1335 0.4117Min 0.0000 0.0000 0.0000SA 0.6687 3.3435 0.3330
Max 0.9529 4.7645 0.4745Min 0.4455 0.0000 0.0000SA 0.2231 1.1155 0.1111
Max 0.7597 3.7985 0.3783Min 0.0320 0.1600 0.0159SA 0.7868 3.9340 0.3918
Max 1.2510 6.2550 0.6230Min 0.2465 1.2325 0.1228SA 0.4001 2.0005 0.1992
Max 0.9778 4.8890 0.4869Min 0.0000 0.0000 0.0000SA 0.5594 2.7970 0.2786
Max 1.1240 5.6200 0.5598Min 0.1373 0.6865 0.0684SA 0.2186 1.0930 0.1089
Max 0.5610 2.8050 0.2794Min 0.0412 0.2060 0.0205SA 0.0943 0.4715 0.0470
Max 0.6870 3.4350 0.3421Min 0.0000 0.0000 0.0000SA 0.3019 1.5095 0.1503
Max 0.8155 4.0775 0.4061Min 0.0293 0.1465 0.0146SA 0.2224 1.1120 0.1108
Max 0.8018 4.0090 0.3993Min 0.0000 0.0000 0.0000SA 0.2254 1.1270 0.1122
Max 1.0330 5.1650 0.5144Min 0.0366 0.1830 0.0182
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
DD 9 Room D2 2.0-4.0 14:42 ON
DD 10 Portable 1.0-4.0 16:39 OFF
DD 9 Room D2 N/A 16:28 OFF
DD 10 Portable 1.0-4.0 14:58 ON
DD 8 Room D6 3.0-5.0 14:12 ON
DD 8 Room D6 3.0-5.0 16:19 OFF
DD 7 Room C4 2.0-4.0 14:01 ON
DD 7 Room C4 2.0-4.0 16:10 OFF
DD 6 Room C1 2.0-4.0 13:53 ON
DD 6 Room C1 2.0-4.0 15:55 OFF
DD 5 Hallway outside C5 2.0-5.0 13:45 ON
DD 5 Hallway outside C5 2.0-5.0 16:03 OFF
DD 4 Room B3 2.0-4.0 13:35 ON
DD 4 Room B3 2.0-4.0 15:47 OFF
DD 3 Library 2.0-4.0 13:26 ON
DD 3 Library 2.0-4.0 15:38 OFF
DD 2 Room A4 2.0-4.0 13:18 ON
DD 2 Room A4 2.0-4.0 15:29 OFF
DD 1 General Office 2.0-4.0 13:10 ON
DD 1 General Office 2.0-4.0 15:21 OFF
Attachment B7 Fallingbrook M.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 7: Field Measurements Fallingbrook Middle School
Page 1
February 7, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 1.0410 5.2050 0.5184Max 2.0320 10.1600 1.0119Min 0.3646 1.8230 0.1816SA 0.6883 3.4415 0.3428
Max 1.1180 5.5900 0.5568Min 0.1697 0.8485 0.0845SA 0.7039 3.5195 0.3505
Max 0.9552 4.7760 0.4757Min 0.2517 1.2585 0.1253SA 0.4143 2.0715 0.2063
Max 0.7375 3.6875 0.3673Min 0.0000 0.0000 0.0000SA 0.6490 3.2450 0.3232
Max 0.9560 4.7800 0.4761Min 0.2826 1.4130 0.1407SA 0.2491 1.2455 0.1241
Max 0.7609 3.8045 0.3789Min 0.0000 0.0000 0.0000SA 0.0034 0.0170 0.0017
Max 0.9458 4.7290 0.4710Min 0.0000 0.0000 0.0000SA 0.0177 0.0885 0.0088
Max 0.9045 4.5225 0.4504Min 0.0000 0.0000 0.0000SA 0.0885 0.4425 0.0441
Max 0.5502 2.7510 0.2740Min 0.0000 0.0000 0.0000SA 0.2624 1.3120 0.1307
Max 0.8866 4.4330 0.4415Min 0.0000 0.0000 0.0000SA 0.0569 0.2845 0.0283
Max 0.7501 3.7505 0.3735Min 0.0000 0.0000 0.0000SA 0.0300 0.1500 0.0149
Max 0.5460 2.7300 0.2719Min 0.0000 0.0000 0.0000SA 0.0902 0.4510 0.0449
Max 0.5524 2.7620 0.2751Min 0.0000 0.0000 0.0000SA 0.0428 0.2140 0.0213
Max 1.3600 6.8000 0.6773Min 0.0000 0.0000 0.0000SA 0.4002 2.0010 0.1993
Max 0.9595 4.7975 0.4778Min 0.0000 0.0000 0.0000SA 0.1055 0.5275 0.0525
Max 0.6965 3.4825 0.3469Min 0.0000 0.0000 0.0000SA 0.1742 0.8710 0.0868
Max 0.5536 2.7680 0.2757Min 0.0000 0.0000 0.0000SA 0.2334 1.1670 0.1162
Max 2.0520 10.2600 1.0219Min 0.0000 0.0000 0.0000SA 0.2936 1.4680 0.1462
Max 0.7228 3.6140 0.3600Min 0.0000 0.0000 0.0000SA 0.1824 0.9120 0.0908
Max 1.4370 7.1850 0.7156Min 0.0000 0.0000 0.0000SA 0.3084 1.5420 0.1536
Max 0.7068 3.5340 0.3520Min 0.0117 0.0585 0.0058SA 0.3678 1.8390 0.1832
Max 1.1130 5.5650 0.5543Min 0.0000 0.0000 0.0000SA 0.2333 1.1665 0.1162
Max 0.7027 3.5135 0.3499Min 0.0000 0.0000 0.0000SA 0.1081 0.5405 0.0538
Max 0.2328 1.1640 0.1159Min 0.0000 0.0000 0.0000SA 0.4394 2.1970 0.2188
Max 0.7684 3.8420 0.3827Min 0.1229 0.6145 0.0612SA 0.2935 1.4675 0.1462
Max 1.1460 5.7300 0.5707Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
FB 13 Room 202 2.0-4.0 17:28 OFF
FB 12 Library 0.9-1.8 17:20 OFF
FB 13 Room 202 2.0-4.0 14:01 ON
FB 11 Room 204 2.0-4.0 17:09 OFF
FB 12 Library 0.9-1.8 13:51 ON
FB 10 Hall outside 204 0.6-1.5 13:25 ON
FB 11 Room 204 2.0-4.0 13:43 ON
FB 10 Hall outside 204 0.6-1.5 17:02 OFF
FB 9 Room 210 2.0-4.0 13:26 ON
FB 9 Room 210 2.0-4.0 16:53 OFF
FB 8 Room 101 3.0-5.0 13:11 ON
FB 8 Room 101 3.0-5.0 16:09 OFF
FB 7 Room 123 3.0-5.0 13:02 ON
FB 7 Room 123 3.0-5.0 16:25 OFF
FB 6 Hall outside 120 0.6-1.5 12:52 ON
FB 6 Hall outside 120 0.6-1.5 16:17 OFF
FB 5 Room 114 2.0-4.0 12:44 ON
FB 5 Room 114 2.0-4.0 16:42 OFF
FB 4 Room 110 3.0-5.0 12:35 ON
FB 4 Room 110 3.0-5.0 16:33 OFF
FB 3 Work Room (1st Floor)
3.0-5.0 12:25 ON
FB 3 Work Room (1st Floor)
3.0-5.0 15:56 OFF
FB 2 Staffroom (1st Floor)
3.0-5.0 12:16 ON
FB 2 Staffroom (1st Floor)
3.0-5.0 15:48 OFF
FB 1 General Office (1st Floor)
0.6-1.5 12:08 ON
FB 1 General Office (1st Floor)
0.6-1.5 15:40 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 7: Field Measurements Fallingbrook Middle School
Page 2
February 7, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3988 1.9940 0.1986Max 1.0550 5.2750 0.5254Min 0.0137 0.0685 0.0068SA 0.2581 1.2905 0.1285
Max 1.0220 5.1100 0.5090Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
FB 14 Portable 0.3-1.2 15:28 OFF
FB 14 Portable 0.3-1.2 15:21 ON
Attachment B8 Fletcher’s Meadow S.S.
EMR TestingPeel District School Board
Table 8: Field Measurements Fletcher's Meadow Secondary School
Page 1
February 18-19, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1106 0.5530 0.0551Max 0.4567 2.2835 0.2274Min 0.0000 0.0000 0.0000SA 0.0111 0.0555 0.0055
Max 0.4756 2.3780 0.2368Min 0.0000 0.0000 0.0000SA 0.7770 3.8850 0.3869
Max 0.2984 1.4920 0.1486Min 0.0000 0.0000 0.0000SA 0.0067 0.0335 0.0033
Max 0.1990 0.9950 0.0991Min 0.0000 0.0000 0.0000SA 0.3345 1.6725 0.1666
Max 0.6043 3.0215 0.3009Min 0.0725 0.3625 0.0361SA 0.1846 0.9230 0.0919
Max 0.9873 4.9365 0.4917Min 0.0000 0.0000 0.0000SA 0.5077 2.5385 0.2528
Max 0.8012 4.0060 0.3990Min 0.2628 1.3140 0.1309SA 0.3057 1.5285 0.1522
Max 0.8371 4.1855 0.4169Min 0.0000 0.0000 0.0000SA 0.4382 2.1910 0.2182
Max 0.6383 3.1915 0.3179Min 0.2197 1.0985 0.1094SA 0.2425 1.2125 0.1208
Max 0.8033 4.0165 0.4000Min 0.0275 0.1375 0.0137SA 0.6626 3.3130 0.3300
Max 0.8737 4.3685 0.4351Min 0.3668 1.8340 0.1827SA 0.3282 1.6410 0.1634
Max 0.8567 4.2835 0.4266Min 0.0000 0.0000 0.0000SA 0.3541 1.7705 0.1763
Max 0.7055 3.5275 0.3513Min 0.1758 0.8790 0.0875SA 0.0978 0.4890 0.0487
Max 0.6028 3.0140 0.3002Min 0.0000 0.0000 0.0000SA 0.4552 2.2760 0.2267
Max 0.8389 4.1945 0.4178Min 0.2149 1.0745 0.1070SA 0.0790 0.3950 0.0393
Max 0.4277 2.1385 0.2130Min 0.0000 0.0000 0.0000SA 0.4045 2.0225 0.2014
Max 0.7155 3.5775 0.3563Min 0.2025 1.0125 0.1008SA 0.1290 0.6450 0.0642
Max 0.4964 2.4820 0.2472Min 0.0000 0.0000 0.0000SA 0.3919 1.9595 0.1952
Max 0.8750 4.3750 0.4358Min 0.1648 0.8240 0.0821SA 0.1464 0.7320 0.0729
Max 0.5442 2.7210 0.2710Min 0.0000 0.0000 0.0000SA 0.4614 2.3070 0.2298
Max 0.7116 3.5580 0.3544Min 0.2472 1.2360 0.1231SA 0.2475 1.2375 0.1233
Max 0.7417 3.7085 0.3694Min 0.0000 0.0000 0.0000SA 0.5306 2.6530 0.2642
Max 0.7969 3.9845 0.3969Min 0.2526 1.2630 0.1258SA 0.2727 1.3635 0.1358
Max 0.6545 3.2725 0.3259Min 0.0000 0.0000 0.0000SA 0.3963 1.9815 0.1974
Max 0.6694 3.3470 0.3334Min 0.1556 0.7780 0.0775SA 0.1166 0.5830 0.0581
Max 0.8079 4.0395 0.4023Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
FM 1 General Office 1-1.5 12:52 ON
FM 1 General Office 1-1.5 15:23 OFF
FM 2 Cafetorium 1.5-2 1:01 ON
FM 2 Cafetorium 1.5-2 15:31 OFF
FM 3 Hallway (outside room 203)
1-1.5 13:12 ON
FM 3 Hallway (outside room 203)
1-1.5 15:39 OFF
FM 4 Room 105 3.0-5.0 13:19 ON
FM 4 Room 105 3.0-5.0 15:47 OFF
FM 5 Room 108 1-1.5 13:28 ON
FM 5 Room 108 1-1.5 15:54 OFF
FM 6 Room 201 3.0-5.0 13:42 ON
FM 6 Room 201 3.0-5.0 16:03 OFF
FM 7 Room 205 1-1.5 13:51 ON
FM 7 Room 205 1-1.5 16:11 OFF
FM 8 Hallway (outside room 208)
1-1.5 14:07 ON
FM 8 Hallway (outside room 208)
1-1.5 16:19 OFF
FM9 Room 209 1-1.5 14:15 ON
FM9 Room 209 1-1.5 16:28 OFF
FM 10 Room 213 1-1.5 14:23 ON
FM 11 Room 222 2.0-4.0 14:33 ON
FM 10 Room 213 1-1.5 16:36 OFF
FM 11 Room 222 2.0-4.0 16:45 OFF
FM 12 Room 218 2.0-4.0 14:42 ON
FM 12 Room 218 2.0-4.0 16:53 OFF
FM 13 Library 3-3.5 14:50 ON
FM 13 Library 3-3.5 17:01 OFF
EMR TestingPeel District School Board
Table 8: Field Measurements Fletcher's Meadow Secondary School
Page 2
February 18-19, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1762 0.8810 0.0877
Max 0.6023 3.0115 0.2999Min 0.0000 0.0000 0.0000SA 0.4595 2.2975 0.2288
Max 0.7681 3.8405 0.3825Min 0.1327 0.6635 0.0661SA 0.2480 1.2400 0.1235
Max 0.7310 3.6550 0.3640Min 0.0275 0.1375 0.0137SA 0.5870 2.9350 0.2923
Max 0.7361 3.6805 0.3666Min 0.3531 1.7655 0.1758SA 0.2418 1.2090 0.1204
Max 0.4439 2.2195 0.2211Min 0.0150 0.0750 0.0075SA 0.5768 2.8840 0.2872
Max 0.8183 4.0915 0.4075Min 0.2060 1.0300 0.1026SA 0.3461 1.7305 0.1724
Max 0.6035 3.0175 0.3005Min 0.1597 0.7985 0.0795SA 0.6256 3.1280 0.3115
Max 0.8807 4.4035 0.4386Min 0.3035 1.5175 0.1511SA 0.3097 1.5485 0.1542
Max 0.4788 2.3940 0.2384Min 0.1465 0.7325 0.0730SA 0.5451 2.7255 0.2715
Max 0.8526 4.2630 0.4246Min 0.2345 1.1725 0.1168SA 0.4148 2.0740 0.2066
Max 0.6569 3.2845 0.3271Min 0.1697 0.8485 0.0845SA 0.5654 2.8270 0.2816
Max 0.7152 3.5760 0.3562Min 0.2058 1.0290 0.1025SA 0.4996 2.4980 0.2488
Max 0.7267 3.6335 0.3619Min 0.2671 1.3355 0.1330SA 0.6010 3.0050 0.2993
Max 1.1070 5.5350 0.5513Min 0.2757 1.3785 0.1373SA 0.4793 2.3965 0.2387
Max 0.6076 3.0380 0.3026Min 0.2485 1.2425 0.1238SA 0.5871 2.9355 0.2924
Max 0.8455 4.2275 0.4211Min 0.2938 1.4690 0.1463SA 0.5758 2.8790 0.2867
Max 0.8816 4.4080 0.4390Min 0.3580 1.7900 0.1783SA 0.5400 2.7000 0.2689
Max 1.0220 5.1100 0.5090Min 0.2196 1.0980 0.1094SA 0.5000 2.5000 0.2490
Max 0.7671 3.8355 0.3820Min 0.2798 1.3990 0.1393SA 0.7705 3.8525 0.3837
Max 1.2340 6.1700 0.6145Min 0.1546 0.7730 0.0770SA 0.4072 2.0360 0.2028
Max 0.7432 3.7160 0.3701Min 0.1602 0.8010 0.0798SA 0.5032 2.5160 0.2506
Max 1.3050 6.5250 0.6499Min 0.0595 0.2975 0.0296SA 0.7491 3.7455 0.3731
Max 1.4960 7.4800 0.7450Min 0.4120 2.0600 0.2052SA 0.3561 1.7805 0.1773
Max 0.7005 3.5025 0.3488Min 0.1294 0.6470 0.0644
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
FM 14 Room 307 2.0-4.0 12:29 ON
FM 14 Room 307 2.0-4.0 16:15 OFF
FM 15 Hallway (outside room 306)
1-1.5 12:37 ON
FM 15 Hallway (outside room 306)
1-1.5 16:22 OFF
FM 16 Hallway (outside room 311)
1-1.5 12:46 ON
FM 16 Hallway (outside room 311)
1-1.5 16:30 OFF
FM17 Room 313 2.0-4.0 12:55 ON
FM17 Room 313 2.0-4.0 16:37 OFF
FM 18 Room 318 3.0-5.0 13:04 ON
FM 18 Room 318 3.0-5.0 16:44 OFF
FM 19 Hallway (outside room 322)
1-1.5 13:12 ON
FM 19 Hallway (outside room 322)
1-1.5 16:52 OFF
FM 20 Room 324 1-1.5 13:20 ON
FM 21 Room 329 2.0-4.0 13:32 ON
FM 20 Room 324 1-1.5 16:59 OFF
FM 21 Room 329 2.0-4.0 17:07 OFF
FM 22 Room 114 1-1.5 13:44 ON
FM 22 Room 114 1-1.5 16:04 OFF
FM 23 Staff Work Room 3
3.0-5.0 13:53 ON
FM 23 Staff Work Room 3
3.0-5.0 15:56 OFF
FM 24 West Portable #2
0.6-1.2 14:06 ON
FM 25 South Portable #9
0.6-1.2 15:37 OFF
FM 24 West Portable #2
0.6-1.2 13:47 OFF
FM 25 South Portable #9
0.6-1.2 14:21 ON
Attachment B9 Glenforest S.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 9: Field Measurements Glenforest Secondary School
Page # 1
February 4-5, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2211 1.1055 0.1101Max 0.5091 2.5455 0.2535Min 0.0000 0.0000 0.0000SA 0.1779 0.8895 0.0886
Max 0.8638 4.3190 0.4302Min 0.0092 0.0460 0.0046SA 0.0669 0.3345 0.0333
Max 0.2490 1.2450 0.1240Min 0.0000 0.0000 0.0000SA 0.1357 0.6785 0.0676
Max 0.8951 4.4755 0.4458Min 0.0046 0.0230 0.0023SA 0.3491 1.7455 0.1739
Max 0.5671 2.8355 0.2824Min 0.0834 0.4170 0.0415SA 0.2311 1.1555 0.1151
Max 0.7796 3.8980 0.3882Min 0.0000 0.0000 0.0000SA 0.2329 1.1645 0.1160
Max 0.4732 2.3660 0.2357Min 0.0778 0.3890 0.0387SA 0.0508 0.2540 0.0253
Max 0.4068 2.0340 0.2026Min 0.0000 0.0000 0.0000SA 0.3225 1.6125 0.1606
Max 0.7936 3.9680 0.3952Min 0.0437 0.2185 0.0218SA 0.1257 0.6285 0.0626
Max 0.6038 3.0190 0.3007Min 0.0000 0.0000 0.0000SA 0.3482 1.7410 0.1734
Max 0.5521 2.7605 0.2749Min 0.1282 0.6410 0.0638SA 0.1353 0.6765 0.0674
Max 0.9791 4.8955 0.4876Min 0.0000 0.0000 0.0000SA 0.4358 2.1790 0.2170
Max 0.9300 4.6500 0.4631Min 0.1137 0.5685 0.0566SA 0.2249 1.1245 0.1120
Max 0.6885 3.4425 0.3429Min 0.0000 0.0000 0.0000SA 0.4082 2.0410 0.2033
Max 0.8396 4.1980 0.4181Min 0.1868 0.9340 0.0930SA 0.1909 0.9545 0.0951
Max 0.5638 2.8190 0.2808Min 0.0000 0.0000 0.0000SA 0.0635 0.3175 0.0316
Max 0.5211 2.6055 0.2595Min 0.0000 0.0000 0.0000SA 0.2413 1.2065 0.1202
Max 0.5674 2.8370 0.2826Min 0.0000 0.0000 0.0000SA 0.0705 0.3525 0.0351
Max 0.7486 3.7430 0.3728Min 0.0000 0.0000 0.0000SA 0.2929 1.4645 0.1459
Max 0.8480 4.2400 0.4223Min 0.0000 0.0000 0.0000SA 0.0532 0.2660 0.0265
Max 0.3923 1.9615 0.1954Min 0.0137 0.0685 0.0068SA 0.3445 1.7225 0.1716
Max 0.6190 3.0950 0.3083Min 0.0392 0.1960 0.0195SA 0.0860 0.4300 0.0428
Max 0.4949 2.4745 0.2465Min 0.0000 0.0000 0.0000SA 0.3203 1.6015 0.1595
Max 1.6800 8.4000 0.8366Min 0.0000 0.0000 0.0000SA 0.1479 0.7395 0.0737
Max 0.9142 4.5710 0.4553Min 0.0000 0.0000 0.0000SA 0.2384 1.1920 0.1187
Max 1.2950 6.4750 0.6449Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
G 13 Cafeteria 1.5-2.4 16:57 OFF
G 12 Library 3.0-3.9 16:49 OFF
G 13 Cafeteria 1.5-2.4 13:17 ON
G 11 Room 131 0.6-1.5 16:40 OFF
G 12 Library 3.0-3.9 13:08 ON
G 10 Auditorium 1.5-2.1 12:51 ON
G 11 Room 131 0.6-1.5 13:00 ON
G 10 Auditorium 1.5-2.1 16:14 OFF
G 9 Room 112 0.6-1.5 12:42 ON
G 9 Room 112 0.6-1.5 16:05 OFF
G 8 General Office (1st Floor) 0.6-1.5 12:14 ON
G 8 General Office (1st Floor) 0.6-1.5 13:47 OFF
G 7 Guidance Office (1st Floor) 0.9-1.8 12:06 ON
G 7 Guidance Office (1st Floor) 0.9-1.8 15:39 OFF
G 6 Room 102 3.0-5.0 11:57 ON
G 6 Room 102 3.0-5.0 15:31 OFF
G 5 Room 115A 0.6-1.5 11:49 ON
G 5 Room 115A 0.6-1.5 15:24 OFF
G 4 Room 114 0.6-1.5 11:42 ON
G 4 Room 114 0.6-1.5 15:15 OFF
G3 Room 106 0.6-1.5 11:30 ON
G3 Room 106 0.6-1.5 15:56 OFF
G2 Gym 0.9-1.8 11:13 ON
G2 Gym 0.9-1.8 16:31 OFF
G 1 Hall outside Gym 0.6-1.5 11:05 ON
G 1 Hall outside Gym 0.6-1.5 16:23 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 9: Field Measurements Glenforest Secondary School
Page # 2
February 4-5, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.0578 0.2890 0.0288Max 0.8279 4.1395 0.4123Min 0.0008 0.0040 0.0004SA 0.1726 0.8630 0.0860
Max 0.5834 2.9170 0.2905Min 0.0000 0.0000 0.0000SA 0.1348 0.6740 0.0671
Max 1.0380 5.1900 0.5169Min 0.0000 0.0000 0.0000SA 0.3270 1.6350 0.1628
Max 1.0980 5.4900 0.5468Min 0.0641 0.3205 0.0319SA 0.1467 0.7335 0.0731
Max 0.8730 4.3650 0.4348Min 0.0000 0.0000 0.0000SA 0.1508 0.7540 0.0751
Max 0.6724 3.3620 0.3349Min 0.0000 0.0000 0.0000SA 0.0477 0.2385 0.0238
Max 0.2763 1.3815 0.1376Min 0.0000 0.0000 0.0000SA 0.1806 0.9030 0.0899
Max 0.7819 3.9095 0.3894Min 0.0000 0.0000 0.0000SA 0.1797 0.8985 0.0895
Max 0.4985 2.4925 0.2483Min 0.0183 0.0915 0.0091SA 0.2790 1.3950 0.1389
Max 0.6338 3.1690 0.3156Min 0.1109 0.5545 0.0552SA 0.4213 2.1065 0.2098
Max 1.4210 7.1050 0.7077Min 0.1153 0.5765 0.0574SA 0.3679 1.8395 0.1832
Max 0.9387 4.6935 0.4675Min 0.0778 0.3890 0.0387SA 0.0745 0.3725 0.0371
Max 0.2396 1.1980 0.1193Min 0.0000 0.0000 0.0000SA 0.1539 0.7695 0.0766
Max 0.6399 3.1995 0.3187Min 0.0287 0.1435 0.0143SA 0.1781 0.8905 0.0887
Max 0.7394 3.6970 0.3682Min 0.0000 0.0000 0.0000SA 0.2914 1.4570 0.1451
Max 0.6475 3.2375 0.3225Min 0.0000 0.0000 0.0000SA 0.5508 2.7540 0.2743
Max 1.2790 6.3950 0.6369Min 0.1580 0.7900 0.0787SA 0.2400 1.2000 0.1195
Max 0.8368 4.1840 0.4167Min 0.0000 0.0000 0.0000SA 0.4846 2.4230 0.2413
Max 0.8628 4.3140 0.4297Min 0.2610 1.3050 0.1300SA 0.9629 4.8145 0.4795
Max 1.8140 9.0700 0.9034Min 0.2400 1.2000 0.1195SA 0.0035 0.0175 0.0017
Max 0.0732 0.3660 0.0365Min 0.0000 0.0000 0.0000SA 0.1152 0.5760 0.0574
Max 0.2106 1.0530 0.1049Min 0.0183 0.0915 0.0091SA 0.1276 0.6380 0.0635
Max 0.5974 2.9870 0.2975Min 0.0000 0.0000 0.0000SA 0.2847 1.4235 0.1418
Max 0.9012 4.5060 0.4488Min 0.0000 0.0000 0.0000SA 0.0387 0.1935 0.0193
Max 0.4114 2.0570 0.2049Min 0.0000 0.0000 0.0000SA 0.2685 1.3425 0.1337
Max 1.3930 6.9650 0.6937Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
G 26 Business Office (2nd Floor) 0.6-1.5 17:24 OFF
G 25 Room 217 0.6-1.5 17:32 OFF
G 26 Business Office (2nd Floor) 0.6-1.5 12:59 ON
G 24 Exercise Room (2nd Floor) 0.9-2.1 16:06 OFF
G 25 Room 217 0.6-1.5 12:49 ON
G 23 Room 128 0.9-2.1 15:43 OFF
G 24 Exercise Room (2nd Floor) 0.9-2.1 12:32 ON
G 22 Room 108 2.0-4.0 15:56 OFF
G 23 Room 128 0.9-2.1 12:07 ON
G 21 hallway outside storage room 0.6-1.5 17:28 OFF
G 22 Room 108 2.0-4.0 11:53 ON
G 21 hallway outside storage room 0.6-1.5 14:32 ON
G 20 Room 142 0.6-1.5 17:45 OFF
G19 Room 144 3.0-5.0 17:53 OFF
G 20 Room 142 0.6-1.5 14:21 ON
G 18 Room 139 0.9-1.8 17:36 OFF
G19 Room 144 3.0-5.0 14:13 ON
G 17 Room 124 0.6-1.5 18:02 OFF
G 18 Room 139 0.9-1.8 14:04 ON
G 16 Room 135 0.6-1.5 17:05 OFF
G 17 Room 124 0.6-1.5 13:51 ON
G 15 Staff Room (1st Floor) 1.8-2.4 17:20 OFF
G 16 Room 135 0.6-1.5 13:42 ON
G 14 Room 137 0.6-1.5 17:13 OFF
G 15 Staff Room (1st Floor) 1.8-2.4 13:34 ON
G 14 Room 137 0.6-1.5 13:26 ON
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 9: Field Measurements Glenforest Secondary School
Page # 3
February 4-5, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1368 0.6840 0.0681Max 2.2830 11.4150 1.1369Min 0.0000 0.0000 0.0000SA 0.3430 1.7150 0.1708
Max 0.6496 3.2480 0.3235Min 0.1602 0.8010 0.0798SA 0.2105 1.0525 0.1048
Max 0.8900 4.4500 0.4432Min 0.0000 0.0000 0.0000SA 0.5102 2.5510 0.2541
Max 1.0080 5.0400 0.5020Min 0.1607 0.8035 0.0800SA 0.2379 1.1895 0.1185
Max 0.7555 3.7775 0.3762Min 0.0275 0.1375 0.0137SA 0.4157 2.0785 0.2070
Max 0.7946 3.9730 0.3957Min 0.1770 0.8850 0.0881SA 0.0825 0.4125 0.0411
Max 0.2246 1.1230 0.1119Min 0.0000 0.0000 0.0000SA 0.2142 1.0710 0.1067
Max 0.4623 2.3115 0.2302Min 0.0366 0.1830 0.0182SA 0.1297 0.6485 0.0646
Max 0.3282 1.6410 0.1634Min 0.0000 0.0000 0.0000SA 0.2824 1.4120 0.1406
Max 0.6628 3.3140 0.3301Min 0.0229 0.1145 0.0114SA 0.1378 0.6890 0.0686
Max 0.4205 2.1025 0.2094Min 0.0000 0.0000 0.0000SA 0.2410 1.2050 0.1200
Max 1.4200 7.1000 0.7072Min 0.0000 0.0000 0.0000SA 0.3039 1.5195 0.1513
Max 0.6447 3.2235 0.3211Min 0.0000 0.0000 0.0000SA 0.4178 2.0890 0.2081
Max 0.9921 4.9605 0.4941Min 0.1648 0.8240 0.0821SA 0.1527 0.7635 0.0760
Max 0.3501 1.7505 0.1743Min 0.0000 0.0000 0.0000SA 0.2957 1.4785 0.1473
Max 1.2190 6.0950 0.6071Min 0.0000 0.0000 0.0000SA 0.7364 3.6820 0.3667
Max 1.1180 5.5900 0.5568Min 0.0095 0.0475 0.0047SA 0.1710 0.8550 0.0852
Max 0.7544 3.7720 0.3757Min 0.0000 0.0000 0.0000SA 0.3299 1.6495 0.1643
Max 1.4470 7.2350 0.7206Min 0.0000 0.0000 0.0000SA 0.3952 1.9760 0.1968
Max 0.8860 4.4300 0.4412Min 0.0320 0.1600 0.0159
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
G 36 Portable 9 0.3-1.2 15:20 OFF
G 35 Portable 3 0.3-1.2 15:29 OFF
G 36 Portable 9 0.3-1.2 15:12 ON
G 34 Room 208 2.0-4.0 16:15 OFF
G 35 Portable 3 0.3-1.2 15:03 ON
G 33 Room 214 0.9-1.8 17:08 OFF
G 34 Room 208 2.0-4.0 14:15 ON
G 32 Room 213 0.9-1.8 16:51 OFF
G 33 Room 214 0.9-1.8 14:04 ON
G 31 Room 223 2.0-4.0 16:24 OFF
G 32 Room 213 0.9-1.8 13:55 ON
G 31 Room 223 2.0-4.0 13:43 ON
G 30 Room 211 0.6-1.5 16:42 OFF
G 29 Math Office (2nd Floor) 0.9-1.8 16:33 OFF
G 30 Room 211 0.6-1.5 13:35 ON
G 28 Room 219 0.9-1.8 16:59 OFF
G 29 Math Office (2nd Floor) 0.9-1.8 13:25 ON
G 27 Room 218 0.6-1.5 17:15 OFF
G 28 Room 219 0.9-1.8 13:16 ON
G 27 Room 218 0.6-1.5 13:07 ON
Attachment B10 Herb Campbell P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 10: Field Measurements Herb Campbell P.S.
Page 1
January 28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1851 0.9255 0.0922Max 0.5232 2.6160 0.2606Min 0.0000 0.0000 0.0000SA 0.0877 0.4385 0.0437
Max 0.4114 2.0570 0.2049Min 0.0000 0.0000 0.0000SA 0.0649 0.3245 0.0323
Max 0.8918 4.4590 0.4441Min 0.0000 0.0000 0.0000SA 0.0758 0.3790 0.0377
Max 0.4967 2.4835 0.2474Min 0.0000 0.0000 0.0000SA 0.1635 0.8175 0.0814
Max 0.5755 2.8775 0.2866Min 0.0000 0.0000 0.0000SA 0.0590 0.2950 0.0294
Max 0.9567 4.7835 0.4764Min 0.0000 0.0000 0.0000SA 0.2441 1.2205 0.1216
Max 0.6282 3.1410 0.3128Min 0.0000 0.0000 0.0000SA 0.3936 1.9680 0.1960
Max 2.4790 12.3950 1.2345Min 0.0000 0.0000 0.0000SA 0.4005 2.0025 0.1994
Max 1.2960 6.4800 0.6454Min 0.0644 0.3220 0.0321SA 0.5874 2.9370 0.2925
Max 1.0270 5.1350 0.5114Min 0.0000 0.0000 0.0000SA 0.2023 1.0115 0.1007
Max 1.0270 5.1350 0.5114Min 0.0000 0.0000 0.0000SA 0.2644 1.3220 0.1317
Max 0.9832 4.9160 0.4896Min 0.0000 0.0000 0.0000SA 0.4481 2.2405 0.2232
Max 1.1520 5.7600 0.5737Min 0.0000 0.0000 0.0000SA 0.3057 1.5285 0.1522
Max 1.1070 5.5350 0.5513Min 0.0000 0.0000 0.0000SA 0.3217 1.6085 0.1602
Max 0.8165 4.0825 0.4066Min 0.0000 0.0000 0.0000SA 0.1955 0.9775 0.0974
Max 0.6445 3.2225 0.3210Min 0.0229 0.1145 0.0114SA 0.2284 1.1420 0.1137
Max 0.5450 2.7250 0.2714Min 0.0412 0.2060 0.0205SA 0.1645 0.8225 0.0819
Max 0.8208 4.1040 0.4088Min 0.0000 0.0000 0.0000SA 0.4840 2.4200 0.2410
Max 0.9526 4.7630 0.4744Min 0.0829 0.4145 0.0413SA 0.3078 1.5390 0.1533
Max 1.0910 5.4550 0.5433Min 0.0000 0.0000 0.0000SA 0.4186 2.0930 0.2085
Max 0.8297 4.1485 0.4132Min 0.0000 0.0000 0.0000SA 0.4063 2.0315 0.2023
Max 0.7664 3.8320 0.3817Min 0.0000 0.0000 0.0000SA 0.4615 2.3075 0.2298
Max 2.3420 11.7100 1.1663Min 0.0000 0.0000 0.0000SA 0.3499 1.7495 0.1743
Max 0.8554 4.2770 0.4260Min 0.0000 0.0000 0.0000SA 0.3756 1.8780 0.1870
Max 0.8677 4.3385 0.4321Min 0.0000 0.0000 0.0000SA 0.3158 1.5790 0.1573
Max 0.7297 3.6485 0.3634Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HC 13 Room 205 0.9-2.1 17:53 OFF
HC 12 Room 202 0.9-2.1 17:39 OFF
HC 13 Room 205 0.9-2.1 14:27 ON
HC 11 Room 203 0.9-2.1 17:31 OFF
HC 12 Room 202 0.9-2.1 14:18 ON
HC 10 Room 125 0.9-2.1 13:55 ON
HC 11 Room 203 0.9-2.1 14:10 ON
HC 10 Room 125 0.9-2.1 17:18 OFF
HC 9 Room 122 0.9-2.1 13:37 ON
HC 9 Room 122 0.9-2.1 17:11 OFF
HC 8 Room 116/117 0.9-2.1 13:37 ON
HC 8 Room 116/117 0.9-2.1 16:02 OFF
HC 7 Room 112 2.0-4.0 13:28 ON
HC 7 Room 112 2.0-4.0 16:52 OFF
HC 6 Hall outside 110 0.9-2.1 13:19 ON
HC 6 Hall outside 110 0.9-2.1 16:44 OFF
HC 5 Office (1st Floor)
N/A 13:11 ON
HC 5 Office (1st Floor)
N/A 16:01 OFF
HC 4 Staff Room (1st Floor)
0.6-1.5 13:02 ON
HC 4 Staff Room (1st Floor)
0.6-1.5 16:09 OFF
HC 3 Room 102 0.6-1.5 12:53 ON
HC 3 Room 102 0.6-1.5 16:34 OFF
HC 2 Room 103 0.9-2.1 12:45 ON
HC 2 Room 103 0.9-2.1 16:25 OFF
HC 1 Hall outside VP office
0.9-2.1 12:37 ON
HC 1 Hall outside VP office
0.9-2.1 16:17 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 10: Field Measurements Herb Campbell P.S.
Page 2
January 28, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2914 1.4570 0.1451Max 0.5801 2.9005 0.2889Min 0.0092 0.0460 0.0046SA 0.1453 0.7265 0.0724
Max 0.7539 3.7695 0.3754Min 0.0000 0.0000 0.0000SA 0.5130 2.5650 0.2555
Max 1.1940 5.9700 0.5946Min 0.0000 0.0000 0.0000SA 0.3510 1.7550 0.1748
Max 0.7960 3.9800 0.3964Min 0.0644 0.3220 0.0321
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HC 15 Portable 2 0.3-1.2 15:49 OFF
HC 14 Room 208 0.9-2.1 17:46 OFF
HC 15 Portable 2 0.3-1.2 15:39 ON
HC 14 Room 208 0.9-2.1 14:53 ON
Attachment B11 Hillcrest M.S.
EMRPeel District School Board
Table 11: Field Measurements Hillcrest Middle School
Page 1
February 13, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.4004 2.0020 0.1994Max 0.7115 3.5575 0.3543Min 0.1771 0.8855 0.0882SA 0.0304 0.1520 0.0151
Max 0.2420 1.2100 0.1205Min 0.0000 0.0000 0.0000SA 0.3199 1.5995 0.1593
Max 0.7437 3.7185 0.3704Min 0.1083 0.5415 0.0539SA 0.0466 0.2330 0.0232
Max 0.8376 4.1880 0.4171Min 0.0000 0.0000 0.0000SA 0.2903 1.4515 0.1446
Max 0.4885 2.4425 0.2433Min 0.1511 0.7555 0.0752SA 0.0183 0.0915 0.0091
Max 0.1303 0.6515 0.0649Min 0.0000 0.0000 0.0000SA 0.5672 2.8360 0.2825
Max 1.0150 5.0750 0.5055Min 0.0000 0.0000 0.0000SA 0.2043 1.0215 0.1017
Max 0.7784 3.8920 0.3876Min 0.0000 0.0000 0.0000SA 0.6006 3.0030 0.2991
Max 1.0560 5.2800 0.5259Min 0.3742 1.8710 0.1864SA 0.1826 0.9130 0.0909
Max 0.5351 2.6755 0.2665Min 0.0092 0.0460 0.0046SA 0.5449 2.7245 0.2714
Max 0.7608 3.8040 0.3789Min 0.3768 1.8840 0.1876SA 0.0942 0.4710 0.0469
Max 0.2964 1.4820 0.1476Min 0.0000 0.0000 0.0000SA 0.5670 2.8350 0.2824
Max 0.9438 4.7190 0.4700Min 0.2472 1.2360 0.1231SA 0.1471 0.7355 0.0733
Max 0.4971 2.4855 0.2476Min 0.0000 0.0000 0.0000SA 0.6040 3.0200 0.3008
Max 0.8400 4.2000 0.4183Min 0.4447 2.2235 0.2215SA 0.1334 0.6670 0.0664
Max 0.5058 2.5290 0.2519Min 0.0000 0.0000 0.0000SA 0.6432 3.2160 0.3203
Max 0.8748 4.3740 0.4357Min 0.3760 1.8800 0.1872SA 0.1754 0.8770 0.0873
Max 0.5689 2.8445 0.2833Min 0.0000 0.0000 0.0000SA 0.4517 2.2585 0.2249
Max 0.8283 4.1415 0.4125Min 0.2437 1.2185 0.1214SA 0.1530 0.7650 0.0762
Max 0.6885 3.4425 0.3429Min 0.0000 0.0000 0.0000SA 0.5980 2.9900 0.2978
Max 0.7430 3.7150 0.3700Min 0.3745 1.8725 0.1865SA 0.1133 0.5665 0.0564
Max 0.3626 1.8130 0.1806Min 0.0000 0.0000 0.0000SA 0.6310 3.1550 0.3142
Max 0.8530 4.2650 0.4248Min 0.4516 2.2580 0.2249SA 0.1579 0.7895 0.0786
Max 0.6661 3.3305 0.3317Min 0.0000 0.0000 0.0000SA 0.4803 2.4015 0.2392
Max 0.7623 3.8115 0.3796Min 0.2930 1.4650 0.1459SA 0.1374 0.6870 0.0684
Max 0.5549 2.7745 0.2763Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HMS 1 General Office 3.0-5.0 12:06 ON
HMS 1 General Office 3.0-5.0 15:14 OFF
HMS 2 Hallway outside Room 208 1-1.5 12:15 ON
HMS 2 Hallway outside Room 208 1-1.5 15:23 OFF
HMS 3 Room 203 Outside door 0.3 m
12:28 ON
HMS 3 Room 203 Outside door 0.3 m
15:30 OFF
HMS 4 Hallway outside Room 308 1-1.5 12:37 ON
HMS 4 Hallway outside Room 308 1-1.5 15:46 OFF
HMS 5 Room 310 3.0-5.0 12:46 ON
HMS 5 Room 310 3.0-5.0 15:53 OFF
HMS 6 Room 303 3.0-5.0 12:37 ON
HMS 6 Room 303 3.0-5.0 16:02 OFF
HMS 7 Room 302 2.0-4.0 13:04 ON
HMS 7 Room 302 2.0-4.0 16:09 OFF
HMS 8 Room 202 3.0-5.0 13:14 ON
HMS 8 Room 202 3.0-5.0 15:38 OFF
HMS 9 Room 210 2.0-4.0 13:24 ON
HMS 9 Room 210 2.0-4.0 16:18 OFF
HMS 10 Gym 1.5-2 13:33 ON
HMS 11 Room 108 2.0-4.0 13:44 ON
HMS 10 Gym 1.5-2 17:01 OFF
HMS 11 Room 108 2.0-4.0 16:53 OFF
HMS 12 Library 1.5-1.8 13:52 ON
HMS 12 Library 1.5-1.8 16:46 OFF
HMS 13 Hallway outside Room 103 1.2-1.5 14:02 ON
HMS 13 Hallway outside Room 103 1.2-1.5 16:38 OFF
EMRPeel District School Board
Table 11: Field Measurements Hillcrest Middle School
Page 2
February 13, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.7011 3.5055 0.3491
Max 0.9554 4.7770 0.4758Min 0.3567 1.7835 0.1776SA 0.1023 0.5115 0.0509
Max 0.4784 2.3920 0.2382Min 0.0000 0.0000 0.0000SA 0.5652 2.8260 0.2815
Max 0.9229 4.6145 0.4596Min 0.2426 1.2130 0.1208SA 0.6539 3.2695 0.3256
Max 0.8633 4.3165 0.4299Min 0.4656 2.3280 0.2319
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HMS 14 Room 103 2.0-4.0 14:10 ON
HMS 15 Portable 0.9-1.2 14:30 OFF
HMS 14 Room 103 2.0-4.0 16:31 OFF
HMS 15 Portable 0.9-1.2 14:22 ON
Attachment B12 Humberview S.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 12: Field Measurements Humberview Secondary School
Page 1
January 14-15, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2391 1.1955 0.1191Max 0.7020 3.5100 0.3496Min 0.0000 0.0000 0.0000SA 0.1378 0.6890 0.0686
Max 0.3251 1.6255 0.1619Min 0.0000 0.0000 0.0000SA 0.1802 0.9010 0.0897
Max 0.3750 1.8750 0.1868Min 0.0458 0.2290 0.0228SA 0.1202 0.6010 0.0599
Max 0.3009 1.5045 0.1498Min 0.0000 0.0000 0.0000SA 0.3362 1.6810 0.1674
Max 0.7853 3.9265 0.3911Min 0.1506 0.7530 0.0750SA 0.1587 0.7935 0.0790
Max 0.3526 1.7630 0.1756Min 0.0176 0.0880 0.0088SA 0.4360 2.1800 0.2171
Max 0.6292 3.1460 0.3133Min 0.1951 0.9755 0.0972SA 0.2099 1.0495 0.1045
Max 0.3779 1.8895 0.1882Min 0.0425 0.2125 0.0212SA 0.2983 1.4915 0.1486
Max 0.6292 3.1460 0.3133Min 0.1694 0.8470 0.0844SA 0.2105 1.0525 0.1048
Max 1.0850 5.4250 0.5403Min 0.0000 0.0000 0.0000SA 0.4137 2.0685 0.2060
Max 0.6671 3.3355 0.3322Min 0.0778 0.3890 0.0387SA 0.1943 0.9715 0.0968
Max 0.3948 1.9740 0.1966Min 0.0778 0.0000 0.0000SA 0.4856 2.4280 0.2418
Max 0.6676 3.3380 0.3325Min 0.3162 1.5810 0.1575SA 0.1552 0.7760 0.0773
Max 0.3546 1.7730 0.1766Min 0.0000 0.0000 0.0000SA 0.2872 1.4360 0.1430
Max 0.4729 2.3645 0.2355Min 0.1236 0.6180 0.0616SA 0.1038 0.5190 0.0517
Max 0.3562 1.7810 0.1774Min 0.0000 0.0000 0.0000SA 0.4996 2.4980 0.2488
Max 0.6664 3.3320 0.3319Min 0.1236 0.6180 0.0616SA 0.3304 1.6520 0.1645
Max 0.6073 3.0365 0.3024Min 0.0229 0.1145 0.0114SA 0.3970 1.9850 0.1977
Max 0.5867 2.9335 0.2922Min 0.2152 1.0760 0.1072SA 0.1754 0.8770 0.0873
Max 0.4997 2.4985 0.2489Min 0.0351 0.1755 0.0175SA 0.0348 0.1740 0.0173
Max 0.2040 1.0200 0.1016Min 0.0000 0.0000 0.0000SA 0.2187 1.0935 0.1089
Max 0.6073 3.0365 0.3024Min 0.0000 0.0000 0.0000SA 0.0338 0.1690 0.0168
Max 0.1531 0.7655 0.0762Min 0.0000 0.0000 0.0000SA 0.1449 0.7245 0.0722
Max 0.6498 3.2490 0.3236Min 0.0000 0.0000 0.0000SA 0.0661 0.3305 0.0329
Max 0.2030 1.0150 0.1011Min 0.0000 0.0000 0.0000SA 0.0950 0.4750 0.0473
Max 0.2276 1.1380 0.1133Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HV 1 Staff Room 4.0-6.0 10:58 ON
HV 1 Staff Room 4.0-6.0 18:12 OFF
HV 2 Hall outside guidance
0.3- 1.2 11:08 ON
HV 2 Hall outside guidance
0.3- 1.2 18:05 OFF
HV 3 Guidance Office 0.3- 1.2 11:18 ON
HV 3 Guidance Office 0.3- 1.2 17:56 OFF
HV 4 General Office (1st Floor)
0.3- 1.2 11:28 ON
HV 4 General Office (1st Floor)
0.3- 1.2 17:48 OFF
HV 5 Room 101 0.9-1.8 11:39 ON
HV 5 Room 101 0.9-1.8 17:31 OFF
HV 6 Room 104 3.0-5.0 11:48 ON
HV 6 Room 104 3.0-5.0 17:40 OFF
HV 7 Room 106 1.2-2.1 11:58 ON
HV 7 Room 106 1.2-2.1 17:14 OFF
HV 8 Room 108 1.2-2.1 12:12 ON
HV 8 Room 108 1.2-2.1 17:22 OFF
HV 9 Room 109 1.2-2.1 12:22 ON
HV 9 Room 109 1.2-2.1 16:54 OFF
HV 10 Room 111 1.8-2.7 12:31 ON
HV 11 Library 1.2-2.1 13:26 ON
HV 10 Room 111 1.8-2.7 17:03 OFF
HV 11 Library 1.2-2.1 16:43 OFF
HV 12 Cafeteria 1.2-2.1 13:34 ON
HV 12 Cafeteria 1.2-2.1 16:33 OFF
HV 13 Room 118 1.8-2.7 13:44 ON
HV 13 Room 118 1.8-2.7 16:22 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 12: Field Measurements Humberview Secondary School
Page 2
January 14-15, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1176 0.5880 0.0586
Max 0.2809 1.4045 0.1399Min 0.0000 0.0000 0.0000SA 0.1359 0.6795 0.0677
Max 0.4058 2.0290 0.2021Min 0.0000 0.0000 0.0000SA 0.2992 1.4960 0.1490
Max 0.5763 2.8815 0.2870Min 0.0972 0.4860 0.0484SA 0.2147 1.0735 0.1069
Max 0.4333 2.1665 0.2158Min 0.0000 0.0000 0.0000SA 0.1093 0.5465 0.0544
Max 0.1053 0.5265 0.0524Min 0.0000 0.0000 0.0000SA 0.0594 0.2970 0.0296
Max 0.2305 1.1525 0.1148Min 0.0000 0.0000 0.0000SA 0.2078 1.0390 0.1035
Max 0.5017 2.5085 0.2498Min 0.0000 0.0000 0.0000SA 0.1639 0.8195 0.0816
Max 0.3745 1.8725 0.1865Min 0.0000 0.0000 0.0000SA 0.0564 0.2820 0.0281
Max 0.3928 1.9640 0.1956Min 0.0000 0.0000 0.0000SA 0.0194 0.0970 0.0097
Max 0.2634 1.3170 0.1312Min 0.0000 0.0000 0.0000SA 1.1660 5.8300 0.5807
Max 1.6100 8.0500 0.8018Min 0.5790 2.8950 0.2883SA 0.2201 1.1005 0.1096
Max 0.4343 2.1715 0.2163Min 0.0410 0.2050 0.0204SA 0.5573 2.7865 0.2775
Max 0.9306 4.6530 0.4634Min 0.1697 0.8485 0.0845SA 0.0791 0.3955 0.0394
Max 0.6550 3.2750 0.3262Min 0.0000 0.0000 0.0000SA 0.1063 0.5315 0.0529
Max 0.2671 1.3355 0.1330Min 0.0000 0.0000 0.0000SA 0.1578 0.7890 0.0786
Max 0.3687 1.8435 0.1836Min 0.0000 0.0000 0.0000SA 0.0680 0.3400 0.0339
Max 0.1648 0.8240 0.0821Min 0.0000 0.0000 0.0000SA 0.0974 0.4870 0.0485
Max 0.4684 2.3420 0.2333Min 0.0000 0.0000 0.0000SA 0.1977 0.9885 0.0985
Max 0.3895 1.9475 0.1940Min 0.0417 0.2085 0.0208SA 0.1842 0.9210 0.0917
Max 0.4256 2.1280 0.2119Min 0.0275 0.1375 0.0137SA 0.3042 1.5210 0.1515
Max 0.4709 2.3545 0.2345Min 0.1422 0.7110 0.0708SA 0.2233 1.1165 0.1112
Max 0.3892 1.9460 0.1938Min 0.0437 0.2185 0.0218SA 0.3525 1.7625 0.1755
Max 0.3571 1.7855 0.1778Min 0.0320 0.1600 0.0159SA 0.2725 1.3625 0.1357
Max 0.4485 2.2425 0.2234Min 0.0527 0.2635 0.0262SA 0.3310 1.6550 0.1648
Max 0.5172 2.5860 0.2576Min 0.1625 0.8125 0.0809SA 0.3115 1.5575 0.1551
Max 0.9562 4.7810 0.4762Min 0.0732 0.3660 0.0365
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HV 14 Hall outside 114 0.9-1.8 13:54 ON
HV 14 Hall outside 114 0.9-1.8 16:05 OFF
HV 15 Room 114 2.0-4.0 14:02 ON
HV 15 Room 114 2.0-4.0 16:13 OFF
HV 16 Room 131 3.0-5.0 14:14 ON
HV 16 Room 131 3.0-5.0 15:45 OFF
HV 17 Room 135 3.0-5.0 14:25 ON
HV 17 Room 135 3.0-5.0 15:55 OFF
HV 18 Portable 2 0.3-1.2 14:34 ON
HV 18 Portable 2 0.3-1.2 14:45 OFF
HV 19 Room 235 3.0-5.0 14:57 ON
HV 19 Room 235 3.0-5.0 15:33 OFF
HV 20 Room 236 2.0-4.0 15:05 ON
HV 21 Hallway outside custodiam office
0.3-1.2 10:53 ON
HV 20 Room 236 2.0-4.0 15:24 OFF
HV 21 Hallway outside custodiam office
0.3-1.2 15:39 OFF
HV 22 Room 231 3.0-5.0 11:09 ON
HV 22 Room 231 3.0-5.0 15:58 OFF
HV 23 Room 230 3.0-5.0 11:19 ON
HV 23 Room 230 3.0-5.0 15:57 OFF
HV 24 Hall behind 221 0.3-1.2 11:27 ON
HV 24 Hall behind 221 0.3-1.2 16:05 OFF
HV 25 Math Office (2nd Floor)
3.0-5.0 11:37 ON
HV 25 Math Office (2nd Floor)
3.0-5.0 16:16 OFF
HV 26 English Office (2nd Floor)
3.0-5.0 11:50 ON
HV 26 English Office (2nd Floor)
3.0-5.0 17:13 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 12: Field Measurements Humberview Secondary School
Page 3
January 14-15, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.0922 0.4610 0.0459
Max 0.5997 2.9985 0.2987Min 0.0000 0.0000 0.0000SA 0.3972 1.9860 0.1978
Max 0.7954 3.9770 0.3961Min 0.1697 0.8485 0.0845SA 0.3016 1.5080 0.1502
Max 0.4895 2.4475 0.2438Min 0.1144 0.5720 0.0570SA 0.1417 0.7085 0.0706
Max 0.3116 1.5580 0.1552Min 0.0183 0.0915 0.0091SA 0.3401 1.7005 0.1694
Max 0.5076 2.5380 0.2528Min 0.1455 0.7275 0.0725SA 0.1304 0.6520 0.0649
Max 2.0890 10.4450 1.0403Min 0.0000 0.0000 0.0000SA 0.3378 1.6890 0.1682
Max 0.8374 4.1870 0.4170Min 0.0870 0.4350 0.0433SA 0.1838 0.9190 0.0915
Max 1.3190 6.5950 0.6569Min 0.0092 0.0460 0.0046SA 0.3927 1.9635 0.1956
Max 0.5559 2.7795 0.2768Min 0.1868 0.9340 0.0930SA 0.2285 1.1425 0.1138
Max 0.4513 2.2565 0.2247Min 0.0137 0.0685 0.0068SA 0.0959 0.4795 0.0478
Max 0.2544 1.2720 0.1267Min 0.0000 0.0000 0.0000SA 0.2174 1.0870 0.1083
Max 0.4096 2.0480 0.2040Min 0.0458 0.2290 0.0228SA 0.2376 1.1880 0.1183
Max 0.4707 2.3535 0.2344Min 0.0595 0.2975 0.0296SA 0.1999 0.9995 0.0996
Max 0.6081 3.0405 0.3028Min 0.0137 0.0685 0.0068SA 0.2012 1.0060 0.1002
Max 0.4012 2.0060 0.1998Min 0.0366 0.1830 0.0182SA 0.1250 0.6250 0.0623
Max 0.3404 1.7020 0.1695Min 0.0000 0.0000 0.0000SA 0.2246 1.1230 0.1119
Max 0.3801 1.9005 0.1893Min 0.0366 0.1830 0.0182SA 0.2246 1.1230 0.1119
Max 0.3801 1.9005 0.1893Min 0.0000 0.0000 0.0000SA 0.0430 0.2150 0.0214
Max 0.7254 3.6270 0.3612Min 0.0000 0.0000 0.0000SA 0.0426 0.2130 0.0212
Max 0.8264 4.1320 0.4115Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HV 27 Room 204B 0.9-1.8 13:34 ON
HV 27 Room 204B 0.9-1.8 16:34 OFF
HV 28 Room 207 0.9-1.8 12:09 ON
HV 28 Room 207 0.9-1.8 16:26 OFF
HV 29 Hall outside 204A
0.3-1.2 12:18 ON
HV 29 Hall outside 204A
0.3-1.2 16:43 OFF
HV 30 Room 200B 3.0-5.0 12:27 ON
HV 31 Room 201 3.0-5.0 12:37 ON
HV 30 Room 200B 3.0-5.0 16:54 OFF
HV 31 Room 201 3.0-5.0 17:03 OFF
HV 32 Room 212 0.9-1.8 13:47 ON
HV 32 Room 212 0.9-1.8 17:21 OFF
HV 33 Room 213 1.2-2.1 13:57 ON
HV 33 Room 213 1.2-2.1 17:29 OFF
HV 34 Outside room 216
0.6-1.5 14:09 ON
HV 34 Outside room 216
0.6-1.5 15:28 OFF
HV 35 Room 221 3.0-5.0 14:19 ON
HV 36 Room 216 3.0-5.0 15:21 OFF
HV 35 Room 221 3.0-5.0 17:38 OFF
HV 36 Room 216 3.0-5.0 15:11 ON
Attachment B13 Huttonville P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 13: Field Measurements Huttonville Public School
Page 1
February 21, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.6530 3.2650 0.3252Max 1.0650 5.3250 0.5304Min 0.2049 1.0245 0.1020SA 0.1526 0.7630 0.0760
Max 0.5373 2.6865 0.2676Min 0.0000 0.0000 0.0000SA 0.2658 1.3290 0.1324
Max 0.4967 2.4835 0.2474Min 0.0366 0.1830 0.0182SA 0.0769 0.3845 0.0383
Max 0.2752 1.3760 0.1370Min 0.0000 0.0000 0.0000SA 0.3295 1.6475 0.1641
Max 0.5887 2.9435 0.2932Min 0.1191 0.5955 0.0593SA 0.2309 1.1545 0.1150
Max 1.0570 5.2850 0.5264Min 0.0000 0.0000 0.0000SA 0.4873 2.4365 0.2427
Max 0.9119 4.5595 0.4541Min 0.1065 0.5325 0.0530SA 0.1771 0.8855 0.0882
Max 0.3149 1.5745 0.1568Min 0.0926 0.4630 0.0461SA 0.3576 1.7880 0.1781
Max 0.7704 3.8520 0.3837Min 0.1556 0.7780 0.0775SA 0.2422 1.2110 0.1206
Max 0.5628 2.8140 0.2803Min 0.0549 0.2745 0.0273SA 0.4941 2.4705 0.2461
Max 0.7849 3.9245 0.3909Min 0.2467 1.2335 0.1229SA 1.0820 5.4100 0.5388
Max 1.6680 8.3400 0.8307Min 0.0995 0.4975 0.0496SA 0.5000 2.5000 0.2490
Max 0.7562 3.7810 0.3766Min 0.1007 0.5035 0.0501SA 0.1807 0.9035 0.0900
Max 0.3269 1.6345 0.1628Min 0.0595 0.2975 0.0296SA 0.6440 3.2200 0.3207
Max 0.9720 4.8600 0.4841Min 0.3302 1.6510 0.1644SA 0.2779 1.3895 0.1384
Max 1.1460 5.7300 0.5707Min 0.0046 0.0230 0.0023SA 0.4646 2.3230 0.2314
Max 0.7414 3.7070 0.3692Min 0.0778 0.3890 0.0387SA 0.2415 1.2075 0.1203
Max 0.5549 2.7745 0.2763Min 0.0915 0.4575 0.0456SA 0.5430 2.7150 0.2704
Max 0.8722 4.3610 0.4344Min 0.1648 0.8240 0.0821SA 0.2308 1.1540 0.1149
Max 1.5430 7.7150 0.7684Min 0.0000 0.0000 0.0000SA 0.2825 1.4125 0.1407
Max 0.6531 3.2655 0.3252Min 0.1556 0.7780 0.0775SA 0.2151 1.0755 0.1071
Max 0.6183 3.0915 0.3079Min 0.0137 0.0685 0.0068SA 0.3814 1.9070 0.1899
Max 0.9811 4.9055 0.4886Min 0.0503 0.2515 0.0250SA 0.1900 0.9500 0.0946
Max 0.8853 4.4265 0.4409Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
HPS 1 General Office 3.0-5.0 12:22 ON
HPS 1 General Office 3.0-5.0 15:29 OFF
HPS 2 Room 9 2.0-4.0 12:30 ON
HPS 2 Room 9 2.0-4.0 15:37 OFF
HPS 3 Hallway 1-1.5 12:38 ON
HPS 3 Hallway 1-1.5 15:44 OFF
HPS 4 Room 5 3.0-5.0 12:48 ON
HPS 4 Room 5 3.0-5.0 15:52 OFF
HPS 5 Room 21 3.0-5.0 12:59 ON
HPS 5 Room 21 3.0-5.0 16:37 OFF
HPS 6 Room 14 2.0-4.0 13:08 ON
HPS 6 Room 14 2.0-4.0 17:05 OFF
HPS 7 Hallway 0.9-1.2 13:16 ON
HPS 7 Hallway 0.9-1.2 16:20 OFF
HPS 8 Library 1-1.5 13:25 ON
HPS 8 Library 1-1.5 16:09 OFF
HPS 9 Room 18 3.0-5.0 13:37 ON
HPS 9 Room 18 3.0-5.0 16:30 OFF
HPS 10 Room 7 2.0-4.0 13:53 ON
HPS 11 Portable #4 0.3-0.9 14:04 ON
HPS 10 Room 7 2.0-4.0 16:00 OFF
HPS 12 Portable #8 0.3-0.9 16:53 OFF
HPS 11 Portable #4 0.3-0.9 16:45 OFF
HPS 12 Portable #8 0.3-0.9 14:22 ON
Attachment B14 Kenollie P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 14: Field Measurements Kenollie Public School
Page 1
February 6, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2042 1.0210 0.1017Max 0.7199 3.5995 0.3585Min 0.1170 0.5850 0.0583SA 0.5863 2.9315 0.2920
Max 1.3610 6.8050 0.6778Min 0.0000 0.0000 0.0000SA 0.3173 1.5865 0.1580
Max 0.7705 3.8525 0.3837Min 0.0234 0.1170 0.0117SA 0.6711 3.3555 0.3342
Max 1.0630 5.3150 0.5294Min 0.0000 0.0000 0.0000SA 0.2239 1.1195 0.1115
Max 0.5272 2.6360 0.2625Min 0.0000 0.0000 0.0000SA 0.2095 1.0475 0.1043
Max 0.9804 4.9020 0.4882Min 0.0000 0.0000 0.0000SA 0.3509 1.7545 0.1747
Max 0.7017 3.5085 0.3494Min 0.0000 0.0000 0.0000SA 0.4693 2.3465 0.2337
Max 2.6450 13.2250 1.3172Min 0.0000 0.0000 0.0000SA 0.3871 1.9355 0.1928
Max 0.6536 3.2680 0.3255Min 0.1098 0.5490 0.0547SA 0.3458 1.7290 0.1722
Max 1.2800 6.4000 0.6374Min 0.0000 0.0000 0.0000SA 0.4710 2.3550 0.2346
Max 1.1960 5.9800 0.5956Min 0.1144 0.5720 0.0570SA 0.5904 2.9520 0.2940
Max 2.3590 11.7950 1.1748Min 0.2014 1.0070 0.1003SA 0.6316 3.1580 0.3145
Max 1.1240 5.6200 0.5598Min 0.0819 0.4095 0.0408SA 0.6737 3.3685 0.3355
Max 1.4670 7.3350 0.7306Min 0.1511 0.7555 0.0752SA 0.5709 2.8545 0.2843
Max 0.8773 4.3865 0.4369Min 0.2381 1.1905 0.1186SA 0.5842 2.9210 0.2909
Max 1.4920 7.4600 0.7430Min 0.0000 0.0000 0.0000SA 0.3484 1.7420 0.1735
Max 0.9673 4.8365 0.4817Min 0.1511 0.7555 0.0752SA 0.3330 1.6650 0.1658
Max 0.7961 3.9805 0.3965Min 0.0412 0.2060 0.0205SA 0.3265 1.6325 0.1626
Max 0.7829 3.9145 0.3899Min 0.1320 0.6600 0.0657SA 0.1572 0.7860 0.0783
Max 1.0150 5.0750 0.5055Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
K 1 Kindergarten room 2.0-4.0 13:30 ON
K 1 Kindergarten room 2.0-4.0 15:50 OFF
K 2 Room 8 3.0-5.0 13:39 ON
K 2 Room 8 3.0-5.0 15:58 OFF
K 3 Hallway outside Room 7 0.9-1.8 13:47 ON
K 3 Hallway outside Room 7 0.9-1.8 16:06 OFF
K 4 Hallway outside Room 4 1.5-2.4 13:58 ON
K 4 Hallway outside Room 4 1.5-2.4 16:29 OFF
K 5 Room 5 2.0-4.0 14:06 ON
K 5 Room 5 2.0-4.0 16:21 OFF
K 6 Library 0.6-1.5 14:17 ON
K 6 Library 0.6-1.5 16:37 OFF
K 10 Portable 0.3-1.2 15:39 OFF
K 10 Portable 0.3-1.2 14:56 ON
K 9 Room 10 3.0-5.0 14:44 ON
K 9 Room 10 3.0-5.0 16:14 OFF
K 7 Room 3 3.0-5.0 14:26 ON
K 7 Room 3 3.0-5.0 16:52 OFF
K 8 General Office 3.0-5.0 14:35 ON
K 8 General Office 3.0-5.0 16:45 OFF
Attachment B15 Lorne Park S.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 15: Field Measurements Lorne Park Secondary School
Page 1
March 18-19, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1974 0.9870 0.0983Max 1.0300 5.1500 0.5129Min 0.0000 0.0000 0.0000SA 0.1376 0.6880 0.0685
Max 0.7569 3.7845 0.3769Min 0.0000 0.0000 0.0000SA 0.3217 1.6085 0.1602
Max 0.7648 3.8240 0.3809Min 0.0000 0.0000 0.0000SA 0.1373 0.6865 0.0684
Max 1.4580 7.2900 0.7261Min 0.0000 0.0000 0.0000SA 0.3293 1.6465 0.1640
Max 2.8140 14.0700 1.4014Min 0.0000 0.0000 0.0000SA 0.1006 0.5030 0.0501
Max 2.0060 10.0300 0.9990Min 0.0000 0.0000 0.0000SA 0.4922 2.4610 0.2451
Max 1.6760 8.3800 0.8346Min 0.0000 0.0000 0.0000SA 0.1534 0.7670 0.0764
Max 4.3100 21.5500 2.1464Min 0.0000 0.0000 0.0000SA 0.4147 2.0735 0.2065
Max 1.6000 8.0000 0.7968Min 0.1007 0.5035 0.0501SA 0.1884 0.9420 0.0938
Max 0.9809 4.9045 0.4885Min 0.0000 0.0000 0.0000SA 0.3069 1.5345 0.1528
Max 0.5541 2.7705 0.2759Min 0.1419 0.7095 0.0707SA 0.1008 0.5040 0.0502
Max 0.8315 4.1575 0.4141Min 0.0000 0.0000 0.0000SA 0.3437 1.7185 0.1712
Max 1.3250 6.6250 0.6599Min 0.0366 0.1830 0.0182SA 0.0940 0.4700 0.0468
Max 1.4880 7.4400 0.7410Min 0.0000 0.0000 0.0000SA 0.5110 2.5550 0.2545
Max 0.9053 4.5265 0.4508Min 0.2630 1.3150 0.1310SA 0.2323 1.1615 0.1157
Max 0.5124 2.5620 0.2552Min 0.0300 0.1500 0.0149SA 0.3076 1.5380 0.1532
Max 0.5590 2.7950 0.2784Min 0.0915 0.4575 0.0456SA 0.1200 0.6000 0.0598
Max 0.5467 2.7335 0.2723Min 0.0046 0.0230 0.0023SA 0.0524 0.2620 0.0261
Max 0.8562 4.2810 0.4264Min 0.0000 0.0000 0.0000SA 0.3198 1.5990 0.1593
Max 1.1500 5.7500 0.5727Min 0.0000 0.0000 0.0000SA 0.0805 0.4025 0.0401
Max 1.5980 7.9900 0.7958Min 0.0000 0.0000 0.0000SA 0.1552 0.7760 0.0773
Max 1.9940 9.9700 0.9930Min 0.0000 0.0000 0.0000SA 0.0401 0.2005 0.0200
Max 0.9310 4.6550 0.4636Min 0.0000 0.0000 0.0000SA 0.1178 0.5890 0.0587
Max 0.4849 2.4245 0.2415Min 0.0000 0.0000 0.0000SA 0.0053 0.0265 0.0026
Max 0.1694 0.8470 0.0844Min 0.0000 0.0000 0.0000SA 0.0600 0.3000 0.0299
Max 0.3999 1.9995 0.1992Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
LP 1 Guidance Room 0.6-1.5 11:19 ON
LP 1 Guidance Room 0.6-1.5 15:43 OFF
LP 2 General Office (1st Floor)
1.2-2.1 11:29 ON
LP 2 General Office (1st Floor)
1.2-2.1 15:51 OFF
LP 3 Lecture Room (1st Floor)
0.9-1.8 11:39 ON
LP 3 Lecture Room (1st Floor)
0.9-1.8 16:00 OFF
LP 4 Library 2.1-3.0 11:52 ON
LP 4 Library 2.1-3.0 16:17 OFF
LP 5 Room 123 3.0-5.0 12:01 ON
LP 5 Room 123 3.0-5.0 16:33 OFF
LP 6 Room 132 3.0-5.0 12:10 ON
LP 6 Room 132 3.0-5.0 16:49 OFF
LP 7 Hall outside 133 0.9-1.8 12:18 ON
LP 7 Hall outside 133 0.9-1.8 16:57 OFF
LP 8 Room 134 3.0-5.0 12:26 ON
LP 8 Room 134 3.0-5.0 17:04 OFF
LP 9 Staff Room 3.0-5.0 12:37 ON
LP 9 Staff Room 3.0-5.0 17:20 OFF
LP 10 Room 105 1.2-2.1 12:50 ON
LP 11 Cafeteria 1.2-2.1 12:58 ON
LP 10 Room 105 1.2-2.1 17:29 OFF
LP 11 Cafeteria 1.2-2.1 17:37 OFF
LP 12 Room 154 0.9-1.8 13:08 ON
LP 12 Room 154 0.9-1.8 17:45 OFF
LP 13 Gym C 0.6-1.5 13:20 ON
LP 13 Gym C 0.6-1.5 17:53 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 15: Field Measurements Lorne Park Secondary School
Page 2
March 18-19, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.5708 2.8540 0.2843
Max 0.9489 4.7445 0.4726Min 0.0489 0.2445 0.0244SA 0.5943 2.9715 0.2960
Max 1.0420 5.2100 0.5189Min 0.1740 0.8700 0.0867SA 0.1220 0.6100 0.0608
Max 1.0720 5.3600 0.5339Min 0.0000 0.0000 0.0000SA 0.1352 0.6760 0.0673
Max 0.8076 4.0380 0.4022Min 0.0000 0.0000 0.0000SA 0.0660 0.3300 0.0329
Max 0.1607 0.8035 0.0800Min 0.0000 0.0000 0.0000SA 0.1226 0.6130 0.0611
Max 1.5040 7.5200 0.7490Min 0.0000 0.0000 0.0000SA 0.0761 0.3805 0.0379
Max 0.2414 1.2070 0.1202Min 0.0000 0.0000 0.0000SA 0.0919 0.4595 0.0458
Max 0.3635 1.8175 0.1810Min 0.0000 0.0000 0.0000SA 0.1606 0.8030 0.0800
Max 0.4152 2.0760 0.2068Min 0.0000 0.0000 0.0000SA 0.1931 0.9655 0.0962
Max 0.3383 1.6915 0.1685Min 0.1544 0.7720 0.0769SA 0.1719 0.8595 0.0856
Max 1.0030 5.0150 0.4995Min 0.0000 0.0000 0.0000SA 0.2341 1.1705 0.1166
Max 0.8208 4.1040 0.4088Min 0.0000 0.0000 0.0000SA 0.1131 0.5655 0.0563
Max 0.5119 2.5595 0.2549Min 0.0000 0.0000 0.0000SA 0.0830 0.4150 0.0413
Max 0.3376 1.6880 0.1681Min 0.0000 0.0000 0.0000SA 0.4719 2.3595 0.2350
Max 0.7901 3.9505 0.3935Min 0.1463 0.7315 0.0729SA 0.4232 2.1160 0.2108
Max 0.6623 3.3115 0.3298Min 0.1669 0.8345 0.0831SA 0.1068 0.5340 0.0532
Max 0.3157 1.5785 0.1572Min 0.0000 0.0000 0.0000SA 0.3092 1.5460 0.1540
Max 0.5340 2.6700 0.2659Min 0.1195 0.5975 0.0595SA 0.2188 1.0940 0.1090
Max 0.5178 2.5890 0.2579Min 0.0000 0.0000 0.0000SA 0.4004 2.0020 0.1994
Max 1.9680 9.8400 0.9801Min 0.0046 0.0230 0.0023SA 0.2952 1.4760 0.1470
Max 0.5676 2.8380 0.2827Min 0.0593 0.2965 0.0295SA 0.1655 0.8275 0.0824
Max 0.3558 1.7790 0.1772Min 0.0000 0.0000 0.0000SA 0.2769 1.3845 0.1379
Max 0.8017 4.0085 0.3992Min 0.0000 0.0000 0.0000SA 0.0468 0.2340 0.0233
Max 0.3923 1.9615 0.1954Min 0.0000 0.0000 0.0000SA 0.3697 1.8485 0.1841
Max 0.7697 3.8485 0.3833Min 0.1556 0.7780 0.0775SA 0.2120 1.0600 0.1056
Max 1.3720 6.8600 0.6833Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
LP 14 Room 164 0.9-1.8 13:31 ON
LP 14 Room 164 0.9-1.8 18:01 OFF
LP 15 Room 117 2.0-4.0 13:42 ON
LP 15 Room 117 2.0-4.0 15:34 OFF
LP 16 Room 126 2.0-4.0 13:52 ON
LP 16 Room 126 2.0-4.0 16:41 OFF
LP 17 Hall outside 201 0.6-1.5 14:11 ON
LP 17 Hall outside 201 0.6-1.5 15:21 OFF
LP 18 Room 204 2.0-4.0 14:20 ON
LP 18 Room 204 2.0-4.0 15:09 OFF
LP 19 Room 210 2.0-4.0 14:28 ON
LP 19 Room 210 2.0-4.0 15:00 OFF
LP 20 Room 211 2.0-4.0 14:38 ON
LP 21 Room 148 3.0-5.0 12:13 ON
LP 20 Room 211 2.0-4.0 14:52 OFF
LP 21 Room 148 3.0-5.0 16:07 OFF
LP 22 Room 140 2.0-4.0 12:23 ON
LP 22 Room 140 2.0-4.0 15:55 OFF
LP 23 Room 160 0.9-1.8 12:32 ON
LP 23 Room 160 0.9-1.8 16:23 OFF
LP 24 Hall outside 102 0.6-1.5 12:43 ON
LP 24 Hall outside 102 0.6-1.5 14:57 OFF
LP 25 Room 205 2.0-4.0 12:53 ON
LP 25 Room 205 2.0-4.0 15:07 OFF
LP 26 Room 215 2.0-4.0 13:34 ON
LP 26 Room 215 2.0-4.0 15:17 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 15: Field Measurements Lorne Park Secondary School
Page 3
March 18-19, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.4118 2.0590 0.2051
Max 0.7249 3.6245 0.3610Min 0.0000 0.0000 0.0000SA 0.3395 1.6975 0.1691
Max 0.5551 2.7755 0.2764Min 0.1198 0.5990 0.0597SA 0.4272 2.1360 0.2127
Max 0.7552 3.7760 0.3761Min 0.2264 1.1320 0.1127SA 0.3337 1.6685 0.1662
Max 0.7234 3.6170 0.3603Min 0.0183 0.0915 0.0091SA 0.3654 1.8270 0.1820
Max 1.0200 5.1000 0.5080Min 0.0046 0.0230 0.0023SA 0.1664 0.8320 0.0829
Max 0.5814 2.9070 0.2895Min 0.0092 0.0460 0.0046SA 0.2445 1.2225 0.1218
Max 0.4694 2.3470 0.2338Min 0.0687 0.3435 0.0342SA 0.1922 0.9610 0.0957
Max 0.5605 2.8025 0.2791Min 0.0732 0.3660 0.0365
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
LP 27 Room 222 3.0-5.0 13:04 ON
LP 27 Room 222 3.0-5.0 15:25 OFF
LP 28 Hall outside 223 0.9-1.8 13:13 ON
LP 28 Hall outside 223 0.9-1.8 15:33 OFF
LP 29 Room 227 0.9-1.8 13:21 ON
LP 30 Main Entrance 3.0-5.0 16:34 OFF
LP 29 Room 227 0.9-1.8 15:41 OFF
LP 30 Main Entrance 3.0-5.0 13:49 ON
Attachment B16 Lougheed M.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 16: Field Measurements Lougheed Middle School
Page 1
January 22, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.0355 0.1775 0.0177Max 0.1725 0.8625 0.0859Min 0.0000 0.0000 0.0000SA 0.5703 2.8515 0.2840
Max 0.9832 4.9160 0.4896Min 0.3311 1.6555 0.1649SA 0.1097 0.5485 0.0546
Max 0.3483 1.7415 0.1735Min 0.0000 0.0000 0.0000SA 0.5184 2.5920 0.2582
Max 0.7371 3.6855 0.3671Min 0.3320 1.6600 0.1653SA 0.2274 1.1370 0.1132
Max 0.4111 2.0555 0.2047Min 0.0366 0.1830 0.0182SA 0.6166 3.0830 0.3071
Max 0.9820 4.9100 0.4890Min 0.1968 0.9840 0.0980SA 0.5016 2.5080 0.2498
Max 0.7091 3.5455 0.3531Min 0.2714 1.3570 0.1352SA 0.9060 4.5300 0.4512
Max 1.1920 5.9600 0.5936Min 0.5906 2.9530 0.2941SA 0.1974 0.9870 0.0983
Max 0.4025 2.0125 0.2004Min 0.0699 0.3495 0.0348SA 0.6610 3.3050 0.3292
Max 0.8400 4.2000 0.4183Min 0.4903 2.4515 0.2442SA 0.3737 1.8685 0.1861
Max 0.5567 2.7835 0.2772Min 0.1282 0.6410 0.0638SA 0.6052 3.0260 0.3014
Max 0.8040 4.0200 0.4004Min 0.4182 2.0910 0.2083SA 0.3742 1.8710 0.1864
Max 0.5442 2.7210 0.2710Min 0.1865 0.9325 0.0929SA 0.6891 3.4455 0.3432
Max 0.8570 4.2850 0.4268Min 0.5343 2.6715 0.2661SA 0.3611 1.8055 0.1798
Max 0.5233 2.6165 0.2606Min 0.1994 0.9970 0.0993SA 0.6645 3.3225 0.3309
Max 0.8091 4.0455 0.4029Min 0.4745 2.3725 0.2363SA 0.3725 1.8625 0.1855
Max 0.5747 2.8735 0.2862Min 0.0666 0.3330 0.0332SA 0.6987 3.4935 0.3480
Max 0.8934 4.4670 0.4449Min 0.4737 2.3685 0.2359SA 0.4768 2.3840 0.2374
Max 0.7328 3.6640 0.3649Min 0.2827 1.4135 0.1408SA 0.6916 3.4580 0.3444
Max 0.8638 4.3190 0.4302Min 0.5131 2.5655 0.2555SA 0.3982 1.9910 0.1983
Max 0.6170 3.0850 0.3073Min 0.2500 1.2500 0.1245SA 0.5890 2.9450 0.2933
Max 0.8305 4.1525 0.4136Min 0.3767 1.8835 0.1876SA 0.4254 2.1270 0.2118
Max 0.6167 3.0835 0.3071Min 0.2264 1.1320 0.1127SA 0.5586 2.7930 0.2782
Max 0.7580 3.7900 0.3775Min 0.2747 1.3735 0.1368SA 0.3922 1.9610 0.1953
Max 0.7765 3.8825 0.3867Min 0.1236 0.6180 0.0616SA 0.5979 2.9895 0.2978
Max 0.7544 3.7720 0.3757Min 0.3974 1.9870 0.1979
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
L 1 Staff Room (1st Floor)
0.6-1.5 11:15 ON
L 1 Staff Room (1st Floor)
0.6-1.5 15:33 OFF
L 2 Hall outside Room 101
0.6-1.5 11:23 ON
L 2 Hall outside Room 101
0.6-1.5 15:40 OFF
L 3 Room 115 0.6-1.5 11:34 ON
L 3 Room 115 0.6-1.5 16:59 OFF
L 4 General Office (1st Floor)
0.6-1.5 11:43 ON
L 4 General Office (1st Floor)
0.6-1.5 16:33 OFF
L 5 Hall outside 112 0.6-1.5 11:52 ON
L 5 Hall outside 112 0.6-1.5 16:41 OFF
L 6 Room 109 2.0-4.0 12:02 ON
L 6 Room 109 2.0-4.0 16:04 OFF
L 7 Room 112 2.0-4.0 12:12 ON
L 7 Room 112 2.0-4.0 16:49 OFF
L 8 Room 107 2.0-4.0 12:20 ON
L 8 Room 107 2.0-4.0 16:13 OFF
L 9 Room 106 2.0-4.0 12:29 ON
L 9 Room 106 2.0-4.0 16:22 OFF
L 10 Outside SMT 0.6-1.5 12:39 ON
L 11 Room 209 2.0-4.0 12:47 ON
L 10 Outside SMT 0.6-1.5 17:16 OFF
L 11 Room 209 2.0-4.0 17:24 OFF
L 12 Room 205 2.0-4.0 12:56 ON
L 12 Room 205 2.0-4.0 17:33 OFF
L 13 Room 202 2.0-4.0 13:05 ON
L 13 Room 202 2.0-4.0 17:42 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 16: Field Measurements Lougheed Middle School
Page 2
January 22, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.4343 2.1715 0.2163
Max 0.6025 3.0125 0.3000Min 0.1739 0.8695 0.0866SA 0.6568 3.2840 0.3271
Max 0.8448 4.2240 0.4207Min 0.3701 1.8505 0.1843SA 0.4470 2.2350 0.2226
Max 0.6297 3.1485 0.3136Min 0.2777 1.3885 0.1383SA 0.7215 3.6075 0.3593
Max 1.2060 6.0300 0.6006Min 0.4528 2.2640 0.2255SA 0.4614 2.3070 0.2298
Max 0.6849 3.4245 0.3411Min 0.2948 1.4740 0.1468SA 0.5730 2.8650 0.2854
Max 0.7519 3.7595 0.3744Min 0.3770 1.8850 0.1877SA 0.4566 2.2830 0.2274
Max 0.6259 3.1295 0.3117Min 0.2948 1.4740 0.1468SA 0.6991 3.4955 0.3482
Max 0.9850 4.9250 0.4905Min 0.4508 2.2540 0.2245SA 0.4326 2.1630 0.2154
Max 0.6063 3.0315 0.3019Min 0.2030 1.0150 0.1011SA 0.5822 2.9110 0.2899
Max 0.7882 3.9410 0.3925Min 0.4050 2.0250 0.2017SA 0.8100 4.0500 0.4034
Max 1.4970 7.4850 0.7455Min 0.2316 1.1580 0.1153SA 0.4816 2.4080 0.2398
Max 0.9582 4.7910 0.4772Min 0.0000 0.0000 0.0000SA 0.1080 0.5400 0.0538
Max 0.4111 2.0555 0.2047Min 0.0000 0.0000 0.0000SA 0.2362 1.1810 0.1176
Max 1.5460 7.7300 0.7699Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = Maximum
L 14 Room 2C 2.0-4.0 13:13 ON
L 14 Room 2C 2.0-4.0 17:58 OFF
L 15 Room 216 2.0-4.0 13:21 ON
L 15 Room 216 2.0-4.0 18:06 OFF
L 16 Room 212 2.0-4.0 13:40 ON
L 16 Room 212 2.0-4.0 18:15 OFF
L 17 Room 201 2.0-4.0 13:40 ON
L 17 Room 201 2.0-4.0 17:49 OFF
L 18 Guidance Room 0.6-1.5 13:55 ON
L 18 Guidance Room 0.6-1.5 15:48 OFF
L 19 Portable 4 0.6-1.5 14:51 ON
L 20 Portable 1 0.6-1.5 15:10 OFF
L 19 Portable 4 0.6-1.5 15:19 OFF
L 20 Portable 1 0.6-1.5 15:02 ON
Attachment B17 Meadowvale S.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 17: Field Measurements Meadowvale Secondary School
Page 1
February 11-12, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3301 1.6505 0.1644Max 0.8086 4.0430 0.4027Min 0.0000 0.0000 0.0000SA 0.0986 0.4930 0.0491
Max 0.4944 2.4720 0.2462Min 0.0000 0.0000 0.0000SA 0.3794 1.8970 0.1889
Max 1.3500 6.7500 0.6723Min 0.0229 0.1145 0.0114SA 0.0749 0.3745 0.0373
Max 1.2950 6.4750 0.6449Min 0.0000 0.0000 0.0000SA 0.3578 1.7890 0.1782
Max 0.7572 3.7860 0.3771Min 0.0547 0.2735 0.0272SA 0.0427 0.2135 0.0213
Max 0.7427 3.7135 0.3699Min 0.0000 0.0000 0.0000SA 0.4530 2.2650 0.2256
Max 0.8768 4.3840 0.4366Min 0.1228 0.6140 0.0612SA 0.0379 0.1895 0.0189
Max 0.6302 3.1510 0.3138Min 0.0000 0.0000 0.0000SA 0.3673 1.8365 0.1829
Max 0.6592 3.2960 0.3283Min 0.1170 0.5850 0.0583SA 0.1532 0.7660 0.0763
Max 0.7219 3.6095 0.3595Min 0.0000 0.0000 0.0000SA 0.4719 2.3595 0.2350
Max 1.3230 6.6150 0.6589Min 0.0931 0.4655 0.0464SA 0.2617 1.3085 0.1303
Max 0.1456 0.7280 0.0725Min 0.0000 0.0000 0.0000SA 0.4089 2.0445 0.2036
Max 0.8526 4.2630 0.4246Min 0.1557 0.7785 0.0775SA 0.0941 0.4705 0.0469
Max 1.0550 5.2750 0.5254Min 0.0000 0.0000 0.0000SA 0.4067 2.0335 0.2025
Max 0.9285 4.6425 0.4624Min 0.0870 0.4350 0.0433SA 0.0458 0.2290 0.0228
Max 0.7531 3.7655 0.3750Min 0.0000 0.0000 0.0000SA 0.3600 1.8000 0.1793
Max 0.9896 4.9480 0.4928Min 0.0000 0.0000 0.0000SA 0.0420 0.2100 0.0209
Max 0.5328 2.6640 0.2653Min 0.0000 0.0000 0.0000SA 0.4184 2.0920 0.2084
Max 0.6648 3.3240 0.3311Min 0.1141 0.5705 0.0568SA 0.0168 0.0840 0.0084
Max 0.5488 2.7440 0.2733Min 0.0000 0.0000 0.0000SA 0.4340 2.1700 0.2161
Max 0.7452 3.7260 0.3711Min 0.1384 0.6920 0.0689SA 0.2565 1.2825 0.1277
Max 0.7492 3.7460 0.3731Min 0.0000 0.0000 0.0000SA 0.4698 2.3490 0.2340
Max 1.5660 7.8300 0.7799Min 0.0778 0.3890 0.0387SA 0.3197 1.5985 0.1592
Max 1.2600 6.3000 0.6275Min 0.0000 0.0000 0.0000SA 0.0071 0.0355 0.0035
Max 0.2656 1.3280 0.1323Min 0.0000 0.0000 0.0000SA 0.1200 0.6000 0.0598
Max 0.7025 3.5125 0.3498Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
MV 1 Guidance Office (1st Floor) 0.9-1.8 10:28 ON
MV 1 Guidance Office (1st Floor) 0.9-1.8 15:07 OFF
MV 2 Staff Room (1st Floor) 0.9-1.8 10:37 ON
MV 2 Staff Room (1st Floor) 0.9-1.8 15:17 OFF
MV 3 Library 0.9-1.8 10:48 ON
MV 3 Library 0.9-1.8 15:41 OFF
MV 4 Room 110 0.9-1.8 10:57 ON
MV 4 Room 110 0.9-1.8 15:32 OFF
MV 5 Room 113 0.9-1.8 11:05 ON
MV 5 Room 113 0.9-1.8 15:54 OFF
MV 6 Room 114 0.9-1.8 11:16 ON
MV 6 Room 114 0.9-1.8 16:03 OFF
MV 7 Room 118 0.9-1.8 11:26 ON
MV 7 Room 118 0.9-1.8 15:15 OFF
MV 8 Room 119 0.9-1.8 11:34 ON
MV 8 Room 119 0.9-1.8 16:23 OFF
MV 9 Room 120 0.9-1.8 11:43 ON
MV 9 Room 120 0.9-1.8 18:03 OFF
MV 10 Room 125 0.9-1.8 11:52 ON
MV 11 Room 126 0.9-1.8 12:00 ON
MV 10 Room 125 0.9-1.8 16:33 OFF
MV 11 Room 126 0.9-1.8 16:42 OFF
MV 12 Room 128 0.9-1.8 12:10 ON
MV 12 Room 128 0.9-1.8 16:50 OFF
MV 13 Hall outside staff washroom 0.6-1.5 11:04 ON
MV 13 Hall outside staff washroom 0.6-1.5 17:22 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 17: Field Measurements Meadowvale Secondary School
Page 2
February 11-12, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3724 1.8620 0.1855Max 0.8017 4.0085 0.3992Min 0.1188 0.5940 0.0592SA 0.1463 0.7315 0.0729
Max 0.7476 3.7380 0.3723Min 0.0000 0.0000 0.0000SA 0.4084 2.0420 0.2034
Max 0.6961 3.4805 0.3467Min 0.2063 1.0315 0.1027SA 0.2170 1.0850 0.1081
Max 1.4560 7.2800 0.7251Min 0.0000 0.0000 0.0000SA 0.3408 1.7040 0.1697
Max 0.8878 4.4390 0.4421Min 0.0275 0.1375 0.0137SA 0.1012 0.5060 0.0504
Max 1.9080 9.5400 0.9502Min 0.0000 0.0000 0.0000SA 0.0080 0.0400 0.0040
Max 0.3221 1.6105 0.1604Min 0.0000 0.0000 0.0000SA 0.2754 1.3770 0.1371
Max 0.6303 3.1515 0.3139Min 0.0293 0.1465 0.0146SA 0.0403 0.2015 0.0201
Max 0.5911 2.9555 0.2944Min 0.0000 0.0000 0.0000SA 0.0411 0.2055 0.0205
Max 0.4331 2.1655 0.2157Min 0.0000 0.0000 0.0000SA 0.2817 1.4085 0.1403
Max 0.8312 4.1560 0.4139Min 0.0000 0.0000 0.0000SA 0.1737 0.8685 0.0865
Max 1.1390 5.6950 0.5672Min 0.0000 0.0000 0.0000SA 0.0647 0.3235 0.0322
Max 0.6427 3.2135 0.3201Min 0.0000 0.0000 0.0000SA 0.0072 0.0360 0.0036
Max 1.3610 6.8050 0.6778Min 0.0000 0.0000 0.0000SA 0.1253 0.6265 0.0624
Max 0.6832 3.4160 0.3402Min 0.0000 0.0000 0.0000SA 0.1252 0.6260 0.0623
Max 0.3267 1.6335 0.1627Min 0.0000 0.0000 0.0000SA 0.1250 0.6250 0.0623
Max 0.5621 2.8105 0.2799Min 0.0000 0.0000 0.0000SA 0.1460 0.7300 0.0727
Max 0.4994 2.4970 0.2487Min 0.0000 0.0000 0.0000SA 0.2055 1.0275 0.1023
Max 1.0240 5.1200 0.5100Min 0.0000 0.0000 0.0000SA 0.2800 1.4000 0.1394
Max 0.8804 4.4020 0.4384Min 0.0000 0.0000 0.0000SA 0.1209 0.6045 0.0602
Max 0.4076 2.0380 0.2030Min 0.0000 0.0000 0.0000SA 0.1658 0.8290 0.0826
Max 0.8631 4.3155 0.4298Min 0.0000 0.0000 0.0000SA 0.2642 1.3210 0.1316
Max 0.6473 3.2365 0.3224Min 0.0000 0.0000 0.0000SA 0.2993 1.4965 0.1491
Max 0.8913 4.4565 0.4439Min 0.0000 0.0000 0.0000SA 0.2843 1.4215 0.1416
Max 0.6793 3.3965 0.3383Min 0.0000 0.0000 0.0000SA 0.3097 1.5485 0.1542
Max 1.0800 5.4000 0.5378Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
MV 14 Room 107 0.9-1.8 12:33 ON
MV 14 Room 107 0.9-1.8 17:16 OFF
MV 15 Room 104 2.7-3.6 12:42 ON
MV 15 Room 104 2.7-3.6 17:24 OFF
MV 16 Room 103 0.9-1.8 12:50 ON
MV 16 Room 103 0.9-1.8 17:32 OFF
MV 17 General Office (1st Floor) 0.9-1.8 13:34 ON
MV 17 General Office (1st Floor) 0.9-1.8 17:52 OFF
MV 18 Auto Shop (room 100) 0.9-1.8 13:44 ON
MV 18 Auto Shop (room 100) 0.9-1.8 17:41 OFF
MV 19 Classroom 133 0.9-1.8 14:05 ON
MV 19 Classroom 133 0.9-1.8 16:59 OFF
MV 20 Classroom 138 0.9-1.8 14:19 ON
MV 21 Classroom 205 0.9-1.8 11:34 ON
MV 20 Classroom 138 0.9-1.8 17:08 OFF
MV 21 Classroom 205 0.9-1.8 15:26 OFF
MV 22 Room 207 0.9-1.8 11:42 ON
MV 22 Room 207 0.9-1.8 15:35 OFF
MV 23 Room 208 0.9-1.8 11:50 ON
MV 23 Room 208 0.9-1.8 15:52 OFF
MV 24 Room 211 0.9-1.8 12:01 ON
MV 24 Room 211 0.9-1.8 15:44 OFF
MV 25 Room 210 0.9-1.8 12:10 ON
MV 25 Room 210 0.9-1.8 16:01 OFF
MV 26 Room 232 0.9-1.8 12:24 ON
MV 26 Room 232 0.9-1.8 16:59 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 17: Field Measurements Meadowvale Secondary School
Page 3
February 11-12, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2209 1.1045 0.1100Max 0.5567 2.7835 0.2772Min 0.0275 0.1375 0.0137SA 0.2490 1.2450 0.1240
Max 0.4882 2.4410 0.2431Min 0.0412 0.2060 0.0205SA 0.3273 1.6365 0.1630
Max 1.1760 5.8800 0.5856Min 0.0117 0.0585 0.0058SA 0.3901 1.9505 0.1943
Max 0.7615 3.8075 0.3792Min 0.1402 0.7010 0.0698SA 0.2971 1.4855 0.1480
Max 0.8923 4.4615 0.4444Min 0.0000 0.0000 0.0000SA 0.3834 1.9170 0.1909
Max 1.2360 6.1800 0.6155Min 0.0000 0.0000 0.0000SA 0.3330 1.6650 0.1658
Max 0.6007 3.0035 0.2991Min 0.1053 0.5265 0.0524SA 0.3505 1.7525 0.1745
Max 0.7689 3.8445 0.3829Min 0.0761 0.3805 0.0379SA 0.2146 1.0730 0.1069
Max 0.4778 2.3890 0.2379Min 0.0000 0.0000 0.0000SA 0.2864 1.4320 0.1426
Max 1.3910 6.9550 0.6927Min 0.0000 0.0000 0.0000SA 0.3180 1.5900 0.1584
Max 0.7185 3.5925 0.3578Min 0.0689 0.3444 0.0343SA 0.3492 1.7460 0.1739
Max 0.8656 4.3280 0.4311Min 0.0458 0.2290 0.0228SA 0.2792 1.3960 0.1390
Max 0.6221 3.1105 0.3098Min 0.0476 0.2380 0.0237SA 0.2281 1.1405 0.1136
Max 0.5312 2.6560 0.2645Min 0.0137 0.0685 0.0068SA 0.1112 0.5560 0.0554
Max 0.4417 2.2085 0.2200Min 0.0000 0.0000 0.0000SA 0.9921 4.9605 0.4941
Max 1.5390 7.6950 0.7664Min 0.0468 0.2340 0.0233SA 0.9188 4.5940 0.4576
Max 1.4630 7.3150 0.7286Min 0.0000 0.0000 0.0000SA 0.4305 2.1525 0.2144
Max 1.0030 5.0150 0.4995Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
MV 27 Room 227 0.9-1.8 12:32 ON
MV 27 Room 227 0.9-1.8 16:52 OFF
MV 28 Room 230 0.9-1.8 12:40 ON
MV 28 Room 230 0.9-1.8 16:43 OFF
MV 29 Room 221 0.9-1.8 12:51 ON
MV 29 Room 221 0.9-1.8 16:26 OFF
MV 30 Room 223 0.9-1.8 13:00 ON
MV 31 Room 214 0.9-1.8 13:09 ON
MV 30 Room 223 0.9-1.8 16:34 OFF
MV 31 Room 214 0.9-1.8 16:18 OFF
MV 32 Room 217 0.9-1.8 13:17 ON
MV 32 Room 217 0.9-1.8 16:10 OFF
MV 33 Room 200 0.9-1.8 13:38 ON
MV 33 Room 200 0.9-1.8 17:08 OFF
MV 34 Gym 0.9-1.8 13:49 ON
MV 35 Portable No visible AP 14:57 OFF
MV 34 Gym 0.9-1.8 15:11 OFF
MV 35 Portable No visible AP 14:43 ON
Attachment B18 Middlebury P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 18: Field Measurements Middlebury Public School
Page 1
February 14, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3958 1.9790 0.1971Max 0.7682 3.8410 0.3826Min 0.0117 0.0585 0.0058SA 0.1289 0.6445 0.0642
Max 0.4641 2.3205 0.2311Min 0.0000 0.0000 0.0000SA 0.3491 1.7455 0.1739
Max 0.6536 3.2680 0.3255Min 0.0819 0.4095 0.0408SA 0.2020 1.0100 0.1006
Max 0.5208 2.6040 0.2594Min 0.0000 0.0000 0.0000SA 0.3047 1.5235 0.1517
Max 0.6157 3.0785 0.3066Min 0.0000 0.0000 0.0000SA 0.1332 0.6660 0.0663
Max 0.3269 1.6345 0.1628Min 0.0046 0.0230 0.0023SA 0.1991 0.9955 0.0992
Max 0.5228 2.6140 0.2604Min 0.0176 0.0880 0.0088SA 0.1128 0.5640 0.0562
Max 0.4315 2.1575 0.2149Min 0.0000 0.0000 0.0000SA 0.4184 2.0920 0.2084
Max 0.7025 3.5125 0.3498Min 0.1327 0.6635 0.0661SA 0.1627 0.8135 0.0810
Max 0.4267 2.1335 0.2125Min 0.0046 0.0230 0.0023SA 0.3916 1.9580 0.1950
Max 0.7160 3.5800 0.3566Min 0.1849 0.9245 0.0921SA 0.2549 1.2745 0.1269
Max 0.5399 2.6995 0.2689Min 0.0549 0.2745 0.0273SA 0.3581 1.7905 0.1783
Max 0.6185 3.0925 0.3080Min 0.1144 0.5720 0.0570SA 0.1413 0.7065 0.0704
Max 0.6109 3.0545 0.3042Min 0.0183 0.0915 0.0091SA 0.5800 2.9000 0.2888
Max 0.8625 4.3125 0.4295Min 0.3493 1.7465 0.1740SA 0.2784 1.3920 0.1386
Max 0.5651 2.8255 0.2814Min 0.0595 0.2975 0.0296SA 0.6934 3.4670 0.3453
Max 1.3610 6.8050 0.6778Min 0.3936 1.9680 0.1960SA 0.4003 2.0015 0.1993
Max 1.5640 7.8200 0.7789Min 0.1061 0.5305 0.0528SA 0.5978 2.9890 0.2977
Max 0.9651 4.8255 0.4806Min 0.1694 0.8470 0.0844SA 0.2796 1.3980 0.1392
Max 0.8315 4.1575 0.4141Min 0.0641 0.3205 0.0319SA 0.6578 3.2890 0.3276
Max 0.9494 4.7470 0.4728Min 0.1974 0.9870 0.0983SA 0.3029 1.5145 0.1508
Max 0.5193 2.5965 0.2586Min 0.0732 0.3660 0.0365SA 0.4469 2.2345 0.2226
Max 0.7643 3.8215 0.3806Min 0.1785 0.8925 0.0889SA 0.2443 1.2215 0.1217
Max 0.5959 2.9795 0.2968Min 0.0732 0.3660 0.0365SA 0.5329 2.6645 0.2654
Max 0.9875 4.9375 0.4918Min 0.3035 1.5175 0.1511SA 0.2046 1.0230 0.1019
Max 0.9941 4.9705 0.4951Min 0.0183 0.0915 0.0091
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
MPS 13 Classroom 21 1-1.5 16:51 OFF
MPS 12 Classroom 20 1-1.5 16:43 OFF
MPS 13 Classroom 21 1-1.5 13:55 ON
MPS 11 Classroom 8 1-1.5 16:34 OFF
MPS 12 Classroom 20 1-1.5 13:46 ON
MPS 10 Classroom 12 1-1.5 13:26 ON
MPS 11 Classroom 8 1-1.5 13:34 ON
MPS 10 Classroom 12 1-1.5 16:26 OFF
MPS 9 Classroom 5 1.5-1.8 13:18 ON
MPS 9 Classroom 5 1.5-1.8 16:19 OFF
MPS 8 Classroom 15 1-1.5 13:06 ON
MPS 8 Classroom 15 1-1.5 16:12 OFF
MPS 7 Hallway (outside kindergarten)
1.2-1.5 12:51 ON
MPS 7 Hallway (outside kindergarten)
1.2-1.5 16:04 OFF
MPS 6 Classroom 18 1.5-1.8 12:50 ON
MPS 6 Classroom 18 1.5-1.8 15:57 OFF
MPS 5 Staff Room 2.0-4.0 12:41 ON
MPS 5 Staff Room 2.0-4.0 15:49 OFF
MPS 4 Hallway (outside staffroom)
1-1.5 12:34 ON
MPS 4 Hallway (outside staffroom)
1-1.5 15:43 OFF
MPS 3 Classroom 1 2.0-4.0 12:25 ON
MPS 3 Classroom 1 2.0-4.0 15:34 OFF
MPS 2 Library 1-1.5 12:17 ON
MPS 2 Library 1-1.5 15:26 OFF
MPS 1 Office 1-1.5 12:09 ON
MPS 1 Office 1-1.5 15:19 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 18: Field Measurements Middlebury Public School
Page 2
February 14, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.4199 2.0995 0.2091
Max 0.6188 3.0940 0.3082Min 0.1923 0.9615 0.0958SA 0.2244 1.1220 0.1118
Max 1.4960 7.4800 0.7450Min 0.0278 0.1390 0.0138SA 0.6156 3.0780 0.3066
Max 3.3560 16.7800 1.6713Min 0.0000 0.0000 0.0000SA 0.3920 1.9600 0.1952
Max 1.5690 7.8450 0.7814Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
MPS 15 Classroom 25 1-1.5 17:05 OFF
MPS 14 Classroom 23 1-1.5 16:58 OFF
MPS 15 Classroom 25 1-1.5 14:11 ON
MPS 14 Classroom 23 1-1.5 14:03 ON
Attachment B19 Mineola P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 19: Field Measurements Mineola Public School
March 6, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1893 0.9465 0.0943Max 1.2480 6.2400 0.6215Min 0.0000 0.0000 0.0000SA 0.3404 1.7020 0.1695
Max 1.0790 5.3950 0.5373Min 0.0000 0.0000 0.0000SA 0.2028 1.0140 0.1010
Max 1.4350 7.1750 0.7146Min 0.0000 0.0000 0.0000SA 0.5158 2.5790 0.2569
Max 1.1360 5.6800 0.5657Min 0.1112 0.5560 0.0554SA 0.2544 1.2720 0.1267
Max 0.6691 3.3455 0.3332Min 0.0000 0.0000 0.0000SA 0.5213 2.6065 0.2596
Max 0.7745 3.8725 0.3857Min 0.0778 0.3890 0.0387SA 0.2415 1.2075 0.1203
Max 0.6386 3.1930 0.3180Min 0.0000 0.0000 0.0000SA 0.8373 4.1865 0.4170
Max 1.6070 8.0350 0.8003Min 0.1509 0.7545 0.0751SA 0.1745 0.8725 0.0869
Max 0.4956 2.4780 0.2468Min 0.0000 0.0000 0.0000SA 0.3973 1.9865 0.1979
Max 1.6270 8.1350 0.8102Min 0.0183 0.0915 0.0091SA 0.3628 1.8140 0.1807
Max 0.7114 3.5570 0.3543Min 0.0000 0.0000 0.0000SA 0.5939 2.9695 0.2958
Max 1.0130 5.0650 0.5045Min 0.2852 1.4260 0.1420SA 0.3086 1.5430 0.1537
Max 0.9506 4.7530 0.4734Min 0.0137 0.0685 0.0068SA 0.4400 2.2000 0.2191
Max 0.9433 4.7165 0.4698Min 0.1053 0.5265 0.0524SA 0.1905 0.9525 0.0949
Max 0.5506 2.7530 0.2742Min 0.0046 0.0230 0.0023SA 0.5183 2.5915 0.2581
Max 0.9757 4.8785 0.4859Min 0.3259 1.6295 0.1623SA 0.3000 1.5000 0.1494
Max 2.1540 10.7700 1.0727Min 0.0000 0.0000 0.0000SA 0.5143 2.5715 0.2561
Max 2.4540 12.2700 1.2221Min 0.0137 0.0685 0.0068SA 0.2021 1.0105 0.1006
Max 0.5564 2.7820 0.2771Min 0.0092 0.0460 0.0046SA 0.2854 1.4270 0.1421
Max 0.5715 2.8575 0.2846Min 0.0644 0.3220 0.0321SA 0.3900 1.9500 0.1942
Max 0.9692 4.8460 0.4827Min 0.0000 0.0000 0.0000SA 0.8808 4.4040 0.4386
Max 1.7280 8.6400 0.8605Min 0.0000 0.0000 0.0000SA 0.4019 2.0095 0.2001
Max 9.2260 46.1300 4.5945Min 0.0046 0.0230 0.0023SA 0.6426 3.2130 0.3200
Max 1.1470 5.7350 0.5712Min 0.1405 0.7025 0.0700SA 1.0530 5.2650 0.5244
Max 3.5710 17.8550 1.7784Min 0.0000 0.0000 0.0000SA 0.3151 1.5755 0.1569
Max 0.6965 3.4825 0.3469Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
M 13 Portable 0.3-1.2 15:53 OFF
M 12 Classroom 122 0.6-1.5 16:10 OFF
M 13 Portable 0.3-1.2 15:09 ON
M 11 Classroom 118 0.6-1.5 16:03 OFF
M 12 Classroom 122 0.6-1.5 14:43 ON
M 10 Hall outside 119 0.6-1.5 14:52 ON
M 11 Classroom 118 0.6-1.5 14:34 ON
M 10 Hall outside 119 0.6-1.5 16:18 OFF
M 9 Staff Room (basement)
2.0-4.0 14:13 ON
M 9 Staff Room (basement)
2.0-4.0 17:39 OFF
M 8 Room 17 2.0-4.0 14:05 ON
M 8 Room 17 2.0-4.0 17:46 OFF
M 7 Classroom 13 2.0-4.0 13:56 ON
M 7 Classroom 13 2.0-4.0 17:23 OFF
M 6 Outside room 15/16
0.6-1.5 13:42 ON
M 6 Outside room 15/16
0.6-1.5 17:31 OFF
M 5 Classroom 1 2.0-4.0 13:31 ON
M 5 Classroom 1 2.0-4.0 17:15 OFF
M 4 General Office (1st Floor)
2.0-4.0 13:22 ON
M 4 General Office (1st Floor)
2.0-4.0 16:42 OFF
M 3 Room 11 2.0-4.0 13:14 ON
M 3 Room 11 2.0-4.0 17:06 OFF
M 2 Room 8 2.0-4.0 13:06 ON
M 2 Room 8 2.0-4.0 16:57 OFF
M 1 Library 0.9-1.8 12:59 ON
M 1 Library 0.9-1.8 16:50 OFF
Attachment B20 Morning Star M.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 20: Field Measurements Morning Star Middle School
Page 1
January 29, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.7875 3.9375 0.3922Max 1.2650 6.3250 0.6300Min 0.3687 1.8435 0.1836SA 0.1399 0.6995 0.0697
Max 2.0130 10.0650 1.0025Min 0.0000 0.0000 0.0000SA 0.8480 4.2400 0.4223
Max 1.0600 5.3000 0.5279Min 0.5841 2.9205 0.2909SA 0.1451 0.7255 0.0723
Max 0.9893 4.9465 0.4927Min 0.0000 0.0000 0.0000SA 0.0725 0.3625 0.0361
Max 0.3789 1.8945 0.1887Min 0.0000 0.0000 0.0000SA 0.1881 0.9405 0.0937
Max 1.0300 5.1500 0.5129Min 0.0000 0.0000 0.0000SA 0.0987 0.4935 0.0492
Max 0.4847 2.4235 0.2414Min 0.0000 0.0000 0.0000SA 0.1094 0.5470 0.0545
Max 1.1250 5.6250 0.5603Min 0.0000 0.0000 0.0000SA 0.2128 1.0640 0.1060
Max 0.4234 2.1170 0.2109Min 0.0000 0.0000 0.0000SA 0.1405 0.7025 0.0700
Max 0.7726 3.8630 0.3848Min 0.0000 0.0000 0.0000SA 0.2338 1.1690 0.1164
Max 0.5017 2.5085 0.2498Min 0.0699 0.3495 0.0348SA 0.2367 1.1835 0.1179
Max 0.8721 4.3605 0.4343Min 0.0000 0.0000 0.0000SA 0.1694 0.8470 0.0844
Max 0.5462 2.7310 0.2720Min 0.0000 0.0000 0.0000SA 0.0822 0.4110 0.0409
Max 0.8453 4.2265 0.4210Min 0.0000 0.0000 0.0000SA 0.1093 0.5465 0.0544
Max 0.5681 2.8405 0.2829Min 0.0000 0.0000 0.0000SA 0.1654 0.8270 0.0824
Max 0.8845 4.4225 0.4405Min 0.0000 0.0000 0.0000SA 0.1588 0.7940 0.0791
Max 0.4908 2.4540 0.2444Min 0.0046 0.0230 0.0023SA 0.0764 0.3820 0.0380
Max 0.6142 3.0710 0.3059Min 0.0000 0.0000 0.0000SA 0.1733 0.8665 0.0863
Max 0.6911 3.4555 0.3442Min 0.0000 0.0000 0.0000SA 0.1434 0.7170 0.0714
Max 0.7962 3.9810 0.3965Min 0.0000 0.0000 0.0000SA 0.2789 1.3945 0.1389
Max 0.5040 2.5200 0.2510Min 0.1048 0.5240 0.0522SA 0.2854 1.4270 0.1421
Max 2.1240 10.6200 1.0578Min 0.0000 0.0000 0.0000SA 0.1921 0.9605 0.0957
Max 0.3455 1.7275 0.1721Min 0.0000 0.0000 0.0000SA 0.1364 0.6820 0.0679
Max 0.9275 4.6375 0.4619Min 0.0000 0.0000 0.0000SA 0.1576 0.7880 0.0785
Max 0.1680 0.8400 0.0837Min 0.0000 0.0000 0.0000SA 0.1236 0.6180 0.0616
Max 1.9430 9.7150 0.9676Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
MS 13 Room 121 0.9-1.8 17:06 OFF
MS 12 Room 116 3.0-5.0 15:29 OFF
MS 13 Room 121 0.9-1.8 12:54 ON
MS 11 Computer Lab (1st floor)
3.0-5.0 15:21 OFF
MS 12 Room 116 3.0-5.0 12:44 ON
MS 10 Staff Lounge 3.0-5.0 12:26 ON
MS 11 Computer Lab (1st floor)
3.0-5.0 12:35 ON
MS 10 Staff Lounge 3.0-5.0 15:13 OFF
MS 9 Room 113 3.0-5.0 12:16 ON
MS 9 Room 113 3.0-5.0 16:38 OFF
MS 8 Hallway outside seminar A
0.6-1.5 12:09 ON
MS 8 Hallway outside seminar A
0.6-1.5 16:53 OFF
MS 7 Library 0.6-1.5 11:59 ON
MS 7 Library 0.6-1.5 15:57 OFF
MS 6 Room 102 3.0-5.0 11:51 ON
MS 6 Room 102 3.0-5.0 15:48 OFF
MS 5 Office (1st floor)
1.2-2.4 11:42 ON
MS 5 Office (1st floor)
1.2-2.4 15:40 OFF
MS 4 Room 106 2.0-4.0 11:33 ON
MS 4 Room 106 2.0-4.0 16:14 OFF
MS 3 Room 108 2.0-4.0 11:24 ON
MS 3 Room 108 2.0-4.0 16:22 OFF
MS 2 Room 110 2.0-4.0 11:15 ON
MS 2 Room 110 2.0-4.0 16:30 OFF
MS 1 Hallway outside seminar C
0.6-1.5 11:04 ON
MS 1 Hallway outside seminar C
0.6-1.5 16:45 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 20: Field Measurements Morning Star Middle School
Page 2
January 29, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2392 1.1960 0.1191Max 0.9937 4.9685 0.4949Min 0.0000 0.0000 0.0000SA 0.3833 1.9165 0.1909
Max 1.1060 5.5300 0.5508Min 0.0000 0.0000 0.0000SA 0.0303 0.1515 0.0151
Max 0.5074 2.5370 0.2527Min 0.0000 0.0000 0.0000SA 0.0493 0.2465 0.0246
Max 1.3500 6.7500 0.6723Min 0.0000 0.0000 0.0000SA 0.0147 0.0735 0.0073
Max 0.6926 3.4630 0.3449Min 0.0000 0.0000 0.0000SA 0.1404 0.7020 0.0699
Max 1.9250 9.6250 0.9587Min 0.0000 0.0000 0.0000SA 0.2872 1.4360 0.1430
Max 1.2360 6.1800 0.6155Min 0.0000 0.0000 0.0000SA 0.3772 1.8860 0.1878
Max 2.1070 10.5350 1.0493Min 0.0000 0.0000 0.0000SA 0.0668 0.3340 0.0333
Max 0.9422 4.7110 0.4692Min 0.0000 0.0000 0.0000SA 0.0142 0.0710 0.0071
Max 1.0310 5.1550 0.5134Min 0.0000 0.0000 0.0000SA 0.0989 0.4945 0.0493
Max 0.7938 3.9690 0.3953Min 0.0000 0.0000 0.0000SA 0.1795 0.8975 0.0894
Max 1.7950 8.9750 0.8939Min 0.0000 0.0000 0.0000SA 0.1627 0.8135 0.0810
Max 0.9282 4.6410 0.4622Min 0.0000 0.0000 0.0000SA 0.1051 0.5255 0.0523
Max 0.5560 2.7800 0.2769Min 0.0000 0.0000 0.0000SA 0.1464 0.7320 0.0729
Max 1.5070 7.5350 0.7505Min 0.0000 0.0000 0.0000SA 0.0995 0.4975 0.0496
Max 0.9377 4.6885 0.4670Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
MS 21 Room 202 0.6-1.5 17:31 OFF
MS 21 Room 202 0.6-1.5 14:33 ON
MS 20 Room 204 3.0-5.0 17:38 OFF
MS 19 Outside ESL (2nd floor)
0.6-1.5 17:45 OFF
MS 20 Room 204 3.0-5.0 14:25 ON
MS 18 Room 213 3.0-5.0 17:53 OFF
MS 19 Outside ESL (2nd floor)
0.6-1.5 14:16 ON
MS 17 Room 214 0.6-1.5 18:03 OFF
MS 18 Room 213 3.0-5.0 14:06 ON
MS 16 Room 219 3.0-5.0 18:10 OFF
MS 17 Room 214 0.6-1.5 13:58 ON
MS 15 Room 103 3.0-5.0 16:05 OFF
MS 16 Room 219 3.0-5.0 13:49 ON
MS 14 Adult Ed. (1st floor)
3.0-5.0 17:19 OFF
MS 15 Room 103 3.0-5.0 13:31 ON
MS 14 Adult Ed. (1st floor)
3.0-5.0 13:21 ON
Attachment B21 North Park S.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 21: Field Measurements North Park Secondary School
Page 1
January 16-17, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1132 0.5660 0.0564Max 0.3173 1.5865 0.1580Min 0.0000 0.0000 0.0000SA 0.0911 0.4555 0.0454
Max 0.4384 2.1920 0.2183Min 0.0000 0.0000 0.0000SA 0.0599 0.2995 0.0298
Max 0.2060 1.0300 0.1026Min 0.0000 0.0000 0.0000SA 0.1806 0.9030 0.0899
Max 0.3722 1.8610 0.1854Min 0.0275 0.1375 0.0137SA 0.1982 0.9910 0.0987
Max 0.3903 1.9515 0.1944Min 0.0488 0.2440 0.0243SA 0.2227 1.1135 0.1109
Max 0.6267 3.1335 0.3121Min 0.0046 0.0230 0.0023SA 0.2424 1.2120 0.1207
Max 0.4277 2.1385 0.2130Min 0.0351 0.1755 0.0175SA 0.2620 1.3100 0.1305
Max 0.6618 3.3090 0.3296Min 0.0229 0.1145 0.0114SA 0.1963 0.9815 0.0978
Max 0.3553 1.7765 0.1769Min 0.0595 0.2975 0.0296SA 0.1344 0.6720 0.0669
Max 0.4050 2.0250 0.2017Min 0.0183 0.0915 0.0091SA 0.2828 1.4140 0.1408
Max 0.4317 2.1585 0.2150Min 0.1282 0.6410 0.0638SA 0.2030 1.0150 0.1011
Max 0.6185 3.0925 0.3080Min 0.0000 0.0000 0.0000SA 0.2838 1.4190 0.1413
Max 0.4495 2.2475 0.2239Min 0.1559 0.7795 0.0776SA 0.2109 1.0545 0.1050
Max 0.6709 3.3545 0.3341Min 0.0000 0.0000 0.0000SA 0.2995 1.4975 0.1492
Max 0.4617 2.3085 0.2299Min 0.1091 0.5455 0.0543SA 0.2079 1.0395 0.1035
Max 0.7704 3.8520 0.3837Min 0.0000 0.0000 0.0000SA 0.2960 1.4800 0.1474
Max 0.4834 2.4170 0.2407Min 0.1292 0.6460 0.0643SA 0.2215 1.1075 0.1103
Max 0.7252 3.6260 0.3611Min 0.0000 0.0000 0.0000SA 0.3287 1.6435 0.1637
Max 0.5009 2.5045 0.2494Min 0.1513 0.7565 0.0753SA 0.1304 0.6520 0.0649
Max 1.0730 5.3650 0.5344Min 0.0000 0.0000 0.0000SA 0.4617 2.3085 0.2299
Max 0.6361 3.1805 0.3168Min 0.2547 1.2735 0.1268SA 0.3069 1.5345 0.1528
Max 0.5402 2.7010 0.2690Min 0.0969 0.4845 0.0483SA 0.3103 1.5515 0.1545
Max 0.4887 2.4435 0.2434Min 0.1582 0.7910 0.0788SA 0.1650 0.8250 0.0822
Max 0.4610 2.3050 0.2296Min 0.0000 0.0000 0.0000SA 0.0240 0.1200 0.0120
Max 0.1554 0.7770 0.0774Min 0.0000 0.0000 0.0000SA 0.2220 1.1100 0.1106
Max 1.0180 5.0900 0.5070Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
NP 13 Room 307 1.5-2.4 17:28 OFF
NP 12 Library 0.9-1.8 15:46 OFF
NP 13 Room 307 1.5-2.4 13:38 ON
NP 11 Office (1st floor)
0.5-1.5 17:03 OFF
NP 12 Library 0.9-1.8 12:45 ON
NP 10 Café 3.6-4.5 12:25 ON
NP 11 Office (1st floor)
0.5-1.5 12:36 ON
NP 10 Café 3.6-4.5 15:19 OFF
NP 9 Room 153 0.5-1.5 12:11 ON
NP 9 Room 153 0.5-1.5 15:27 OFF
NP 8 Room 118 0.5-1.5 12:02 ON
NP 8 Room 118 0.5-1.5 16:46 OFF
NP 7 Room 135 0.5-1.5 11:52 ON
NP 7 Room 135 0.5-1.5 16:37 OFF
NP 6 Room 136 0.9-1.8 11:43 ON
NP 6 Room 136 0.9-1.8 16:29 OFF
NP 5 Room 131 0.9-1.8 11:35 ON
NP 5 Room 131 0.9-1.8 16:21 OFF
NP 4 Classroom 112 0.5-1.5 11:25 ON
NP 4 Classroom 112 0.5-1.5 16:13 OFF
NP 3 Classroom 107 0.5-1.5 11:17 ON
NP 3 Classroom 107 0.5-1.5 16:05 OFF
NP 2 Classroom 104 0.5-1.5 11:07 ON
NP 2 Classroom 104 0.5-1.5 15:56 OFF
NP 1 Classroom 102 0.6-1.5 10:57 ON
NP 1 Classroom 102 0.6-1.5 16:55 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 21: Field Measurements North Park Secondary School
Page 2
January 16-17, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.0330 0.1650 0.0164
Max 0.1373 0.6865 0.0684Min 0.0000 0.0000 0.0000SA 0.1042 0.5210 0.0519
Max 0.7682 3.8410 0.3826Min 0.0000 0.0000 0.0000SA 0.3285 1.6425 0.1636
Max 0.6455 3.2275 0.3215Min 0.0982 0.4910 0.0489SA 0.5145 2.5725 0.2562
Max 0.9341 4.6705 0.4652Min 0.1842 0.9210 0.0917SA 0.1129 0.5645 0.0562
Max 0.3162 1.5810 0.1575Min 0.0000 0.0000 0.0000SA 0.3171 1.5855 0.1579
Max 0.9697 4.8485 0.4829Min 0.0183 0.0915 0.0091SA 0.0943 0.4715 0.0470
Max 0.3304 1.6520 0.1645Min 0.0000 0.0000 0.0000SA 0.2046 1.0230 0.1019
Max 0.3852 1.9260 0.1918Min 0.0534 0.2670 0.0266SA 0.2009 1.0045 0.1000
Max 0.5989 2.9945 0.2983Min 0.0000 0.0000 0.0000SA 0.2168 1.0840 0.1080
Max 0.2326 1.1630 0.1158Min 0.0092 0.0460 0.0046SA 0.0516 0.2580 0.0257
Max 0.4010 2.0050 0.1997Min 0.0000 0.0000 0.0000SA 0.1307 0.6535 0.0651
Max 0.4025 2.0125 0.2004Min 0.0046 0.0230 0.0023SA 0.2499 1.2495 0.1245
Max 0.6960 3.4800 0.3466Min 0.0059 0.0295 0.0029SA 0.3491 1.7455 0.1739
Max 0.9891 4.9455 0.4926Min 0.0000 0.0000 0.0000SA 0.2609 1.3045 0.1299
Max 0.4429 2.2145 0.2206Min 0.7480 3.7400 0.3725SA 0.1655 0.8275 0.0824
Max 0.4289 2.1445 0.2136Min 0.0183 0.0915 0.0091SA 0.2883 1.4415 0.1436
Max 0.4488 2.2440 0.2235Min 0.1043 0.5215 0.0519SA 0.2246 1.1230 0.1119
Max 0.3640 1.8200 0.1813Min 0.0882 0.0000 0.0000SA 0.2975 1.4875 0.1482
Max 0.4656 2.3280 0.2319Min 0.1351 0.6755 0.0673SA 0.0943 0.4715 0.0470
Max 0.2600 1.3000 0.1295Min 0.0000 0.0000 0.0000SA 0.3825 1.9125 0.1905
Max 0.5653 2.8265 0.2815Min 0.1595 0.7975 0.0794SA 0.0317 0.1585 0.0158
Max 0.1730 0.8650 0.0862Min 0.0000 0.0000 0.0000SA 0.3700 1.8500 0.1843
Max 0.5567 2.7835 0.2772Min 0.2037 1.0185 0.1014SA 0.0291 0.1455 0.0145
Max 0.1422 0.7110 0.0708Min 0.0000 0.0000 0.0000SA 0.4550 2.2750 0.2266
Max 0.6742 3.3710 0.3358Min 0.2381 1.1905 0.1186SA 0.3556 1.7780 0.1771
Max 0.7208 3.6040 0.3590Min 0.1495 0.7475 0.0745
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
NP 26 Room 214 0.6-2.5 16:12 OFF
NP 25 Room 232 0.6-2.5 15:23 OFF
NP 26 Room 214 0.6-2.5 12:04 ON
NP 24 Room 234 0.6-1.5 15:31 OFF
NP 25 Room 232 0.6-2.5 11:55 ON
NP 23 Hall outside 236 2.0-4.0 15:39 OFF
NP 24 Room 234 0.6-1.5 11:47 ON
NP 22 Room 237 0.6-1.5 15:56 OFF
NP 23 Hall outside 236 2.0-4.0 11:39 ON
NP 21 Room 238 0.6-1.5 15:48 OFF
NP 22 Room 237 0.6-1.5 11:31 ON
NP 21 Room 238 0.6-1.5 11:22 ON
NP 20 Portable 1 0.3-1.2 17:57 OFF
NP 19 Café Lower 1.8-2.7 17:20 OFF
NP 20 Portable 1 0.3-1.2 11:03 ON
NP 18 Room 123 0.9-1.8 15:36 OFF
NP 19 Café Lower 1.8-2.7 15:08 ON
NP 17 Room 322 0.5-1.5 18:00 OFF
NP 18 Room 123 0.9-1.8 14:28 ON
NP 16 Room 323 - Comp. Lab
0.5-1.5 17:46 OFF
NP 17 Room 322 0.5-1.5 14:13 ON
NP 15 Room 321 - Comm. Tech
0.5-1.5 17:44 OFF
NP 16 Room 323 - Comp. Lab
0.5-1.5 14:05 ON
NP 14 Room 311 0.5-1.5 17:36 OFF
NP 15 Room 321 - Comm. Tech
0.5-1.5 13:57 ON
NP 14 Room 311 0.5-1.5 13:47 ON
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 21: Field Measurements North Park Secondary School
Page 3
January 16-17, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3878 1.9390 0.1931
Max 0.5478 2.7390 0.2728Min 0.1900 0.9500 0.0946SA 0.3390 1.6950 0.1688
Max 0.6210 3.1050 0.3093Min 0.0529 0.2645 0.0263SA 0.3536 1.7680 0.1761
Max 0.7259 3.6295 0.3615Min 0.1373 0.6865 0.0684SA 0.3380 1.6900 0.1683
Max 0.5020 2.5100 0.2500Min 0.1620 0.8100 0.0807SA 0.5027 2.5135 0.2503
Max 0.6780 3.3900 0.3376Min 0.1694 0.8470 0.0844SA 0.2649 1.3245 0.1319
Max 0.4623 2.3115 0.2302Min 0.0961 0.4805 0.0479SA 0.4245 2.1225 0.2114
Max 0.5704 2.8520 0.2841Min 0.2376 1.1880 0.1183SA 0.3680 1.8400 0.1833
Max 0.6086 3.0430 0.3031Min 0.1468 0.7340 0.0731SA 0.4021 2.0105 0.2002
Max 0.5684 2.8420 0.2831Min 0.2416 1.2080 0.1203SA 0.2450 1.2250 0.1220
Max 0.4785 2.3925 0.2383Min 0.0641 0.3205 0.0319SA 0.3911 1.9555 0.1948
Max 0.5569 2.7845 0.2773Min 0.2254 1.1270 0.1122SA 0.3166 1.5830 0.1577
Max 0.7185 3.5925 0.3578Min 0.1007 0.5035 0.0501SA 0.3239 1.6195 0.1613
Max 0.6157 3.0785 0.3066Min 0.1144 0.5720 0.0570SA 0.1954 0.9770 0.0973
Max 0.7081 3.5405 0.3526Min 0.0000 0.0000 0.0000SA 0.1830 0.9150 0.0911
Max 0.4758 2.3790 0.2369Min 0.0000 0.0000 0.0000SA 0.2805 1.4025 0.1397
Max 0.6763 3.3815 0.3368Min 0.0000 0.0000 0.0000SA 0.1057 0.5285 0.0526
Max 0.2747 1.3735 0.1368Min 0.0000 0.0000 0.0000SA 0.2259 1.1295 0.1125
Max 0.4401 2.2005 0.2192Min 0.0915 0.4575 0.0456SA 0.4394 2.1970 0.2188
Max 0.6608 3.3040 0.3291Min 0.2671 1.3355 0.1330SA 0.2080 1.0400 0.1036
Max 0.5826 2.9130 0.2901Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
NP 36 Staff Room 3.0-5.0 17:11 OFF
NP 35 Exercise Room 1.8-2.7 17:27 OFF
NP 36 Staff Room 3.0-5.0 12:56 ON
NP 34 Gym 0.9-1.8 17:18 OFF
NP 35 Exercise Room 1.8-2.7 14:10 ON
NP 33 Room 217 N/A 16:04 OFF
NP 34 Gym 0.9-1.8 13:56 ON
NP 32 Room 218 0.6-2.5 16:42 OFF
NP 33 Room 217 N/A 13:13 ON
NP 31 Room 208 0.6-2.5 16:34 OFF
NP 32 Room 218 0.6-2.5 13:03 ON
NP 31 Room 208 0.6-2.5 12:55 ON
NP 30 Room 210 0.6-2.5 16:50 OFF
NP 29 Room 200 0.6-2.5 16:26 OFF
NP 30 Room 210 0.6-2.5 12:43 ON
NP 28 Room 205 0.6-2.5 16:59 OFF
NP 29 Room 200 0.6-2.5 12:34 ON
NP 27 Room 209 0.6-2.5 17:07 OFF
NP 28 Room 205 0.6-2.5 12:23 ON
NP 27 Room 209 0.6-2.5 12:15 ON
Attachment B22 Port Credit S.S.
EMR TestingPeel District School Board
Table 22: Field Measurements Port Credit Secondary School
Page 1
March 20-21, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.1909 0.9545 0.0951Max 0.3534 1.7670 0.1760Min 0.0351 0.1755 0.0175SA 0.0352 0.1760 0.0175
Max 0.3053 1.5265 0.1520Min 0.0000 0.0000 0.0000SA 0.0599 0.2995 0.0298
Max 0.2063 1.0315 0.1027Min 0.0000 0.0000 0.0000SA 0.0112 0.0560 0.0056
Max 0.1478 0.7390 0.0736Min 0.0000 0.0000 0.0000SA 0.2452 1.2260 0.1221
Max 0.8681 4.3405 0.4323Min 0.0000 0.0000 0.0000SA 0.2558 1.2790 0.1274
Max 2.0060 10.0300 0.9990Min 0.0000 0.0000 0.0000SA 0.3049 1.5245 0.1518
Max 0.5551 2.7755 0.2764Min 0.0906 0.4530 0.0451SA 0.3204 1.6020 0.1596
Max 2.1420 10.7100 1.0667Min 0.0000 0.0000 0.0000SA 0.2999 1.4995 0.1494
Max 0.5070 2.5350 0.2525Min 0.1216 0.6080 0.0606SA 0.0992 0.4960 0.0494
Max 0.4244 2.1220 0.2114Min 0.0000 0.0000 0.0000SA 0.2631 1.3155 0.1310
Max 0.7987 3.9935 0.3978Min 0.0000 0.0000 0.0000SA 0.2454 1.2270 0.1222
Max 0.6855 3.4275 0.3414Min 0.0000 0.0000 0.0000SA 0.2123 1.0615 0.1057
Max 0.6414 3.2070 0.3194Min 0.0458 0.2290 0.0228SA 0.0678 0.3390 0.0338
Max 0.3840 1.9200 0.1912Min 0.0000 0.0000 0.0000SA 0.2009 1.0045 0.1000
Max 0.6750 3.3750 0.3362Min 0.0275 0.1375 0.0137SA 0.0326 0.1630 0.0162
Max 0.2382 1.1910 0.1186Min 0.0000 0.0000 0.0000SA 0.4078 2.0390 0.2031
Max 0.5541 2.7705 0.2759Min 0.2379 1.1895 0.1185SA 0.0557 0.2785 0.0277
Max 0.5511 2.7555 0.2744Min 0.0000 0.0000 0.0000SA 0.4527 2.2635 0.2254
Max 1.3290 6.6450 0.6618Min 0.0320 0.1600 0.0159SA 0.2409 1.2045 0.1200
Max 0.8794 4.3970 0.4379Min 0.0000 0.0000 0.0000SA 0.4138 2.0690 0.2061
Max 0.6300 3.1500 0.3137Min 0.1908 0.9540 0.0950SA 0.1272 0.6360 0.0633
Max 0.4888 2.4440 0.2434Min 0.0000 0.0000 0.0000SA 0.2442 1.2210 0.1216
Max 0.4668 2.3340 0.2325Min 0.0000 0.0000 0.0000SA 0.0595 0.2975 0.0296
Max 0.5634 2.8170 0.2806Min 0.0000 0.0000 0.0000SA 0.4056 2.0280 0.2020
Max 0.7440 3.7200 0.3705Min 0.0351 0.1755 0.0175SA 0.0586 0.2930 0.0292
Max 0.6773 3.3865 0.3373Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
PC 13 Staff Room (1st floor)
2.0-4.0 14:56 OFF
PC 12 Hall outside 106 0.6-1.5 15:39 OFF
PC 13 Staff Room (1st floor)
2.0-4.0 13:19 ON
PC 11 Gen. Office (1st floor)
0.9-1.8 15:06 OFF
PC 12 Hall outside 106 0.6-1.5 13:03 ON
PC 10 Guidance Office (1st floor)
0.6-1.5 12:40 ON
PC 11 Gen. Office (1st floor)
0.9-1.8 12:47 ON
PC 10 Guidance Office (1st floor)
0.6-1.5 15:13 OFF
PC 9 Room 101 3.0-5.0 12:32 ON
PC 9 Room 101 3.0-5.0 15:23 OFF
PC 8 Room 125 3.0-5.0 12:21 ON
PC 8 Room 125 3.0-5.0 17:28 OFF
PC 7 Gym 0.3-1.2 12:13 ON
PC 7 Gym 0.3-1.2 17:20 OFF
PC 6 Outside 127 0.6-1.5 12:05 ON
PC 6 Outside 127 0.6-1.5 16:46 OFF
PC 5 Hall outside Room 128
4.0-6.0 11:57 ON
PC 5 Hall outside Room 128
4.0-6.0 17:11 OFF
PC 4 Room 138 3.0-5.0 11:49 ON
PC 4 Room 138 3.0-5.0 17:03 OFF
PC 3 Room 136 3.0-5.0 11:39 ON
PC 3 Room 136 3.0-5.0 16:55 OFF
PC 2 Room 133 3.0-5.0 11:31 ON
PC 2 Room 133 3.0-5.0 16:35 OFF
PC 1 Hall outside 132 0.6- 1.5 11:23 ON
PC 1 Hall outside 132 0.6- 1.5 16:26 OFF
EMR TestingPeel District School Board
Table 22: Field Measurements Port Credit Secondary School
Page 2
March 20-21, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2914 1.4570 0.1451
Max 0.5065 2.5325 0.2522Min 0.0870 0.4350 0.0433SA 0.2020 1.0100 0.1006
Max 0.4313 2.1565 0.2148Min 0.0000 0.0000 0.0000SA 0.3152 1.5760 0.1570
Max 0.7755 3.8775 0.3862Min 0.0412 0.2060 0.0205SA 0.2697 1.3485 0.1343
Max 0.4593 2.2965 0.2287Min 0.0468 0.2340 0.0233SA 0.3152 1.5760 0.1570
Max 1.6250 8.1250 0.8093Min 0.0000 0.0000 0.0000SA 0.0289 0.1445 0.0144
Max 0.8687 4.3435 0.4326Min 0.0000 0.0000 0.0000SA 0.3279 1.6395 0.1633
Max 0.5338 2.6690 0.2658Min 0.1618 0.8090 0.0806SA 0.0290 0.1450 0.0144
Max 0.4081 2.0405 0.2032Min 0.0000 0.0000 0.0000SA 0.3890 1.9450 0.1937
Max 0.6521 3.2605 0.3247Min 0.2040 1.0200 0.1016SA 0.2286 1.1430 0.1138
Max 0.8394 4.1970 0.4180Min 0.0000 0.0000 0.0000SA 0.4845 2.4225 0.2413
Max 0.7010 3.5050 0.3491Min 0.2582 1.2910 0.1286SA 0.1793 0.8965 0.0893
Max 0.5381 2.6905 0.2680Min 0.0000 0.0000 0.0000SA 0.3283 1.6415 0.1635
Max 0.5638 2.8190 0.2808Min 0.1264 0.6320 0.0629SA 0.0518 0.2590 0.0258
Max 0.2150 1.0750 0.1071Min 0.0000 0.0000 0.0000SA 0.4895 2.4475 0.2438
Max 1.7180 8.5900 0.8556Min 0.0000 0.0000 0.0000SA 0.3903 1.9515 0.1944
Max 1.0740 5.3700 0.5349Min 0.0234 0.1170 0.0117SA 0.2331 1.1655 0.1161
Max 0.6503 3.2515 0.3238Min 0.0000 0.0000 0.0000SA 0.0162 0.0810 0.0081
Max 0.7002 3.5010 0.3487Min 0.0000 0.0000 0.0000SA 0.3473 1.7365 0.1730
Max 0.8073 4.0365 0.4020Min 0.0275 0.1375 0.0137SA 0.0879 0.4395 0.0438
Max 0.2397 1.1985 0.1194Min 0.0000 0.0000 0.0000SA 0.5214 2.6070 0.2597
Max 1.0640 5.3200 0.5299Min 0.3088 1.5440 0.1538SA 0.1687 0.8435 0.0840
Max 0.5567 2.7835 0.2772Min 0.0000 0.0000 0.0000SA 0.4637 2.3185 0.2309
Max 0.6412 3.2060 0.3193Min 0.2768 1.3840 0.1378SA 0.1894 0.9470 0.0943
Max 0.3712 1.8560 0.1849Min 0.0412 0.2060 0.0205SA 0.3922 1.9610 0.1953
Max 0.7613 3.8065 0.3791Min 0.1831 0.9155 0.0912SA 0.2623 1.3115 0.1306
Max 0.4547 2.2735 0.2264Min 0.0137 0.0685 0.0068
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
PC 26 Room 225 3.0-5.0 16:01 OFF
PC 25 Room 218 3.0-5.0 15:53 OFF
PC 26 Room 225 3.0-5.0 12:34 ON
PC 24 Room 213 3.0-5.0 15:38 OFF
PC 25 Room 218 3.0-5.0 12:26 ON
PC 23 Room 208 3.0-5.0 15:30 OFF
PC 24 Room 213 3.0-5.0 12:18 ON
PC 22 Room 112 3.0-5.0 15:05 OFF
PC 23 Room 208 3.0-5.0 12:10 ON
PC 21 Room 109A 3.0-6.0 16:00 OFF
PC 22 Room 112 3.0-5.0 11:46 ON
PC 21 Room 109A 3.0-6.0 13:05 ON
PC 20 Room 205 3.0-5.0 15:15 OFF
PC 19 Hall outside 207 0.9-1.8 15:22 OFF
PC 20 Room 205 3.0-5.0 12:02 ON
PC 18 Room 204 3.0-5.0 17:38 OFF
PC 19 Hall outside 207 0.9-1.8 12:50 ON
PC 17 Room 105 3.0-5.0 15:31 OFF
PC 18 Room 204 3.0-5.0 14:13 ON
PC 16 Library 1.2-2.1 16:17 OFF
PC 17 Room 105 3.0-5.0 14:02 ON
PC 15 Math Office (1st floor)
3.0-5.0 16:08 OFF
PC 16 Library 1.2-2.1 13:53 ON
PC 14 Rooom 108 3.0-5.0 15:52 OFF
PC 15 Math Office (1st floor)
3.0-5.0 13:45 ON
PC 14 Rooom 108 3.0-5.0 13:30 ON
EMR TestingPeel District School Board
Table 22: Field Measurements Port Credit Secondary School
Page 3
March 20-21, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.3642 1.8210 0.1814
Max 0.5730 2.8650 0.2854Min 0.1923 0.9615 0.0958SA 0.1698 0.8490 0.0846
Max 0.4887 2.4435 0.2434Min 0.0000 0.0000 0.0000SA 0.4170 2.0850 0.2077
Max 0.8097 4.0485 0.4032Min 0.1900 0.9500 0.0946SA 0.1904 0.9520 0.0948
Max 0.4035 2.0175 0.2009Min 0.0516 0.2580 0.0257SA 0.4606 2.3030 0.2294
Max 1.1630 5.8150 0.5792Min 0.2197 1.0985 0.1094SA 0.1509 0.7545 0.0751
Max 0.2795 1.3975 0.1392Min 0.0185 0.0925 0.0092SA 0.4621 2.3105 0.2301
Max 0.7137 3.5685 0.3554Min 0.2289 1.1445 0.1140SA 0.1405 0.7025 0.0700
Max 0.2829 1.4145 0.1409Min 0.0000 0.0000 0.0000SA 0.3845 1.9225 0.1915
Max 0.7022 3.5110 0.3497Min 0.1327 0.6635 0.0661SA 0.1322 0.6610 0.0658
Max 0.5180 2.5900 0.2580Min 0.0000 0.0000 0.0000SA 0.3454 1.7270 0.1720
Max 0.7455 3.7275 0.3713Min 0.0687 0.3435 0.0342SA 0.1669 0.8345 0.0831
Max 0.3121 1.5605 0.1554Min 0.0687 0.3435 0.0342SA 0.4624 2.3120 0.2303
Max 0.6859 3.4295 0.3416Min 0.2447 1.2235 0.1219SA 0.1529 0.7645 0.0761
Max 0.3251 1.6255 0.1619Min 0.0458 0.2290 0.0228SA 0.5559 2.7795 0.2768
Max 0.8287 4.1435 0.4127Min 0.1694 0.8470 0.0844SA 0.2239 1.1195 0.1115
Max 1.1470 5.7350 0.5712Min 0.0000 0.0000 0.0000SA 0.0589 0.2945 0.0293
Max 1.3380 6.6900 0.6663Min 0.0000 0.0000 0.0000SA 0.0405 0.2025 0.0202
Max 2.0630 10.3150 1.0274Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
PC 35 Portable 0.6-1.5 14:25 OFF
PC 34 Room 311 3.0-5.0 16:48 OFF
PC 35 Portable 0.6-1.5 14:16 ON
PC 33 Room 302 3.0-5.0 16:17 OFF
PC 34 Room 311 3.0-5.0 13:51 ON
PC 32 Room 315 3.0-5.0 17:05 OFF
PC 33 Room 302 3.0-5.0 13:42 ON
PC 31 Hall outside 312 0.6-1.5 16:56 OFF
PC 32 Room 315 3.0-5.0 13:31 ON
PC 31 Hall outside 312 0.6-1.5 13:24 ON
PC 30 Room 308 3.0-5.0 16:40 OFF
PC 29 Room 305 3.0-5.0 16:31 OFF
PC 30 Room 308 3.0-5.0 13:16 ON
PC 28 Hall outside 303 0.6-1.5 16:24 OFF
PC 29 Room 305 3.0-5.0 13:09 ON
PC 27 Hall outside room 214/216
0.6-1.5 15:45 OFF
PC 28 Hall outside 303 0.6-1.5 13:00 ON
PC 27 Hall outside room 214/216
0.6-1.5 12:43 ON
Attachment B23 Queen Elizabeth Sr. P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 23: Field Measurements Queen Elizabeth Senior Public School
January 31, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.4488 2.2440 0.2235Max 0.9290 4.6450 0.4626Min 0.1697 0.8485 0.0845SA 0.0092 0.0460 0.0046
Max 0.8544 4.2720 0.4255Min 0.0000 0.0000 0.0000SA 0.4828 2.4140 0.2404
Max 0.9229 4.6145 0.4596Min 0.1697 0.8485 0.0845SA 0.0648 0.3240 0.0323
Max 0.9155 4.5775 0.4559Min 0.0000 0.0000 0.0000SA 0.3117 1.5585 0.1552
Max 0.9165 4.5825 0.4564Min 0.0229 0.1145 0.0114SA 0.0572 0.2860 0.0285
Max 0.2964 1.4820 0.1476Min 0.0000 0.0000 0.0000SA 0.4703 2.3515 0.2342
Max 1.1340 5.6700 0.5647Min 0.1491 0.7455 0.0743SA 0.3130 1.5650 0.1559
Max 1.0080 5.0400 0.5020Min 0.0000 0.0000 0.0000SA 0.2116 1.0580 0.1054
Max 0.4561 2.2805 0.2271Min 0.0732 0.3660 0.0365SA 0.0320 0.1600 0.0159
Max 0.3371 1.6855 0.1679Min 0.0000 0.0000 0.0000SA 0.3517 1.7585 0.1751
Max 0.7951 3.9755 0.3960Min 0.0549 0.2745 0.0273SA 0.0910 0.4550 0.0453
Max 0.4439 2.2195 0.2211Min 0.0000 0.0000 0.0000SA 0.5015 2.5075 0.2497
Max 0.9302 4.6510 0.4632Min 0.2615 1.3075 0.1302SA 0.2354 1.1770 0.1172
Max 1.3480 6.7400 0.6713Min 0.0000 0.0000 0.0000SA 0.3422 1.7110 0.1704
Max 0.5414 2.7070 0.2696Min 0.1327 0.6635 0.0661SA 0.1503 0.7515 0.0748
Max 0.8953 4.4765 0.4459Min 0.0000 0.0000 0.0000SA 0.3456 1.7280 0.1721
Max 0.6905 3.4525 0.3439Min 0.1511 0.7555 0.0752SA 0.1251 0.6255 0.0623
Max 0.1608 0.8040 0.0801Min 0.0000 0.0000 0.0000SA 0.3824 1.9120 0.1904
Max 0.8340 4.1700 0.4153Min 0.0458 0.2290 0.0228SA 0.0941 0.4705 0.0469
Max 1.1180 5.5900 0.5568Min 0.0000 0.0000 0.0000SA 0.1897 0.9485 0.0945
Max 0.5727 2.8635 0.2852Min 0.0595 0.2975 0.0296SA 0.1235 0.6175 0.0615
Max 1.0670 5.3350 0.5314Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
QE 1 Staff Room 0.9-1.8 11:45 ON
QE 1 Staff Room 0.9-1.8 14:37 OFF
QE 2 General Office 0.9-1.8 11:53 ON
QE 2 General Office 0.9-1.8 14:45 OFF
QE 3 Home E.C. 0.6-1.5 12:01 ON
QE 3 Home E.C. 0.6-1.5 14:52 OFF
QE 4 Prep Room 4.0-6.0 12:11 ON
QE 4 Prep Room 4.0-6.0 15:36 OFF
QE 5 Science Room 4 3.0-5.0 12:21 ON
QE 5 Science Room 4 3.0-5.0 15:01 OFF
QE 6 Room 5 1.2-1.5 12:29 ON
QE 6 Room 5 1.2-1.5 15:27 OFF
QE 7 Room 10 0.9-1.8 12:38 ON
QE 7 Room 10 0.9-1.8 15:18 OFF
QE 8 Outside Room 12 0.6-1.5 12:46 ON
QE 8 Outside Room 12 0.6-1.5 15:10 OFF
QE 9 Library 1.2-2.4 12:56 ON
QE 10 Classroom 15 0.9-1.8 15:57 OFF
QE 9 Library 1.2-2.4 15:48 OFF
QE 10 Classroom 15 0.9-1.8 13:18 ON
QE 11 Portable 3 0.3-1.2 16:07 OFF
QE 11 Portable 3 0.3-1.2 13:32 ON
Attachment B24 SouthFields Village P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 24: Field Measurements SouthFields Village Public School
Page 1
January 24, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.0843 0.4215 0.0420Max 0.4394 2.1970 0.2188Min 0.0000 0.0000 0.0000SA 0.0850 0.4250 0.0423
Max 0.4378 2.1890 0.2180Min 0.0000 0.0000 0.0000SA 0.0827 0.4135 0.0412
Max 0.2653 1.3265 0.1321Min 0.0000 0.0000 0.0000SA 0.1672 0.8360 0.0833
Max 0.3610 1.8050 0.1798Min 0.0000 0.0000 0.0000SA 0.1038 0.5190 0.0517
Max 0.3592 1.7960 0.1789Min 0.0000 0.0000 0.0000SA 0.1328 0.6640 0.0661
Max 1.0290 5.1450 0.5124Min 0.0000 0.0000 0.0000SA 0.1606 0.8030 0.0800
Max 0.3931 1.9655 0.1958Min 0.0000 0.0000 0.0000SA 0.2096 1.0480 0.1044
Max 1.3410 6.7050 0.6678Min 0.0000 0.0000 0.0000SA 0.3223 1.6115 0.1605
Max 0.5195 2.5975 0.2587Min 0.1475 0.7375 0.0735SA 0.2118 1.0590 0.1055
Max 1.0380 5.1900 0.5169Min 0.0000 0.0000 0.0000SA 0.2640 1.3200 0.1315
Max 0.4620 2.3100 0.2301Min 0.1091 0.5455 0.0543SA 0.0674 0.3370 0.0336
Max 0.6843 3.4215 0.3408Min 0.0000 0.0000 0.0000SA 0.3157 1.5785 0.1572
Max 0.6305 3.1525 0.3140Min 0.1098 0.5490 0.0547SA 0.2363 1.1815 0.1177
Max 0.9618 4.8090 0.4790Min 0.0000 0.0000 0.0000SA 0.2550 1.2750 0.1270
Max 0.5625 2.8125 0.2801Min 0.0458 0.2290 0.0228SA 0.0720 0.3600 0.0359
Max 1.1220 5.6100 0.5588Min 0.0000 0.0000 0.0000SA 0.1419 0.7095 0.0707
Max 0.5753 2.8765 0.2865Min 0.0000 0.0000 0.0000SA 0.2265 1.1325 0.1128
Max 1.3040 6.5200 0.6494Min 0.0000 0.0000 0.0000SA 0.1347 0.6735 0.0671
Max 0.5107 2.5535 0.2543Min 0.0000 0.0000 0.0000SA 0.2049 1.0245 0.1020
Max 1.0830 5.4150 0.5393Min 0.0000 0.0000 0.0000SA 0.3408 1.7040 0.1697
Max 0.7189 3.5945 0.3580Min 0.0000 0.0000 0.0000SA 0.3204 1.6020 0.1596
Max 0.9117 4.5585 0.4540Min 0.0000 0.0000 0.0000SA 0.0127 0.0635 0.0063
Max 0.6961 3.4805 0.3467Min 0.0000 0.0000 0.0000SA 0.1236 0.6180 0.0616
Max 1.4340 7.1700 0.7141Min 0.0000 0.0000 0.0000SA 0.0351 0.1755 0.0175
Max 0.4802 2.4010 0.2391Min 0.0000 0.0000 0.0000SA 0.0141 0.0705 0.0070
Max 0.6440 3.2200 0.3207Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
SFV 1 Hall outside gym
0.9-1.8 10:59 ON
SFV 1 Hall outside gym
0.9-1.8 16:05 OFF
SFV 2 Library 1.2-2.4 11:11 ON
SFV 2 Library 1.2-2.4 16:20 OFF
SFV 3 Room 107 0.9-2.4 11:20 ON
SFV 3 Room 107 0.9-2.4 16:36 OFF
SFV 4 Room 102 0.9-2.4 11:31 ON
SFV 4 Room 102 0.9-2.4 16:44 OFF
SFV 5 Room 105 0.9-2.4 11:40 ON
SFV 5 Room 105 0.9-2.4 16:51 OFF
SFV 6 Room 103/104 0.9-2.4 11:49 ON
SFV 6 Room 103/104 0.9-2.4 16:59 OFF
SFV 7 Room 100/101 1.2-2.1 11:59 ON
SFV 7 Room 100/101 1.2-2.1 15:35 OFF
SFV 8 Hall outside custodian office
0.9-1.8 12:06 ON
SFV 8 Hall outside custodian office
0.9-1.8 15:42 OFF
SFV 9 Lunch Room 4.0-6.0 12:15 ON
SFV 9 Lunch Room 4.0-6.0 15:50 OFF
SFV 10 General Office 1.2-2.4 12:23 ON
SFV 11 Room 112 1.2-2.4 12:32 ON
SFV 10 General Office 1.2-2.4 15:57 OFF
SFV 11 Room 112 1.2-2.4 16:12 OFF
SFV 12 Computer lab 1.2-2.4 12:40 ON
SFV 12 Computer lab 1.2-2.4 16:28 OFF
SFV 13 Room 200 1.2-2.4 12:52 ON
SFV 13 Room 200 1.2-2.4 17:09 OFF
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 24: Field Measurements SouthFields Village Public School
Page 2
January 24, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.0308 0.1540 0.0153Max 0.3756 1.8780 0.1870Min 0.0000 0.0000 0.0000SA 0.0018 0.0090 0.0009
Max 0.3161 1.5805 0.1574Min 0.0000 0.0000 0.0000SA 0.1578 0.7890 0.0786
Max 0.5853 2.9265 0.2915Min 0.0000 0.0000 0.0000SA 0.1008 0.5040 0.0502
Max 1.9590 9.7950 0.9756Min 0.0000 0.0000 0.0000SA 0.1341 0.6705 0.0668
Max 0.7638 3.8190 0.3804Min 0.0000 0.0000 0.0000SA 0.1744 0.8720 0.0869
Max 0.6297 3.1485 0.3136Min 0.0000 0.0000 0.0000SA 0.0527 0.2635 0.0262
Max 0.6888 3.4440 0.3430Min 0.0000 0.0000 0.0000SA 0.0528 0.2640 0.0263
Max 0.6419 3.2095 0.3197Min 0.0000 0.0000 0.0000SA 0.2126 1.0630 0.1059
Max 0.8698 4.3490 0.4332Min 0.0000 0.0000 0.0000SA 0.1092 0.5460 0.0544
Max 0.4682 2.3410 0.2332Min 0.0000 0.0000 0.0000SA 0.0696 0.3480 0.0347
Max 0.6413 3.2065 0.3194Min 0.0000 0.0000 0.0000SA 0.0546 0.2730 0.0272
Max 0.5188 2.5940 0.2584Min 0.0000 0.0000 0.0000SA 0.3012 1.5060 0.1500
Max 0.9575 4.7875 0.4768Min 0.0000 0.0000 0.0000SA 0.1377 0.6885 0.0686
Max 1.2210 6.1050 0.6081Min 0.0000 0.0000 0.0000SA 0.1881 0.9405 0.0937
Max 0.8269 4.1345 0.4118Min 0.0137 0.0685 0.0068SA 0.1076 0.5380 0.0536
Max 0.3102 1.5510 0.1545Min 0.0000 0.0000 0.0000SA 0.0485 0.2425 0.0242
Max 0.5200 2.6000 0.2590Min 0.0000 0.0000 0.0000SA 0.0657 0.3285 0.0327
Max 1.0550 5.2750 0.5254Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
SFV 14 Room 202 1.2-2.4 13:01 ON
SFV 14 Room 202 1.2-2.4 17:18 OFF
SFV 15 Room 204 1.2-2.4 13:09 ON
SFV 15 Room 204 1.2-2.4 17:25 OFF
SFV 16 Room 208 1.2-2.4 13:18 ON
SFV 16 Room 208 1.2-2.4 15:15 OFF
SFV 17 Room 210 1.2-2.4 13:27 ON
SFV 17 Room 210 1.2-2.4 17:44 OFF
SFV 18 Room 211 1.2-2.4 13:37 ON
SFV 18 Room 211 1.2-2.4 17:51 OFF
SFV 19 Room 215 1.2-2.4 13:46 ON
SFV 19 Room 215 1.2-2.4 17:59 OFF
SFV 20 Room 217 1.2-2.4 13:55 ON
SFV 21 Room 219 1.2-2.4 14:43 ON
SFV 20 Room 217 1.2-2.4 18:07 OFF
SFV 22 Room 206 1.2-2.4 17:34 OFF
SFV 21 Room 219 1.2-2.4 18:17 OFF
SFV 22 Room 206 1.2-2.4 14:56 ON
Attachment B25 William G. Davis Sr. P.S.
Electromagnetic Radiation (EMR) TestingPeel District School Board
Table 25: Field Measurements William G Davis Senior Public School
March 24, 2014G2S13600
Measurement I.D. LocationApproximate
Distance from Wi-Fi AP (m)
Sample Type Time Wi-Fi Computer Network
% of Safety Code 6 Limits (controlled)
% of Safety Code 6 Limits (uncontrolled)
Power Density (W/m²)
SA 0.2066 1.0330 0.1029Max 0.5250 2.6250 0.2615Min 0.0000 0.0000 0.0000SA 0.2628 1.3140 0.1309
Max 0.5735 2.8675 0.2856Min 0.0882 0.4410 0.0439SA 0.1093 0.5465 0.0544
Max 0.4796 2.3980 0.2388Min 0.0000 0.0000 0.0000SA 0.0103 0.0515 0.0051
Max 0.4923 2.4615 0.2452Min 0.0000 0.0000 0.0000SA 0.0784 0.3920 0.0390
Max 0.3549 1.7745 0.1767Min 0.0000 0.0000 0.0000SA 0.2398 1.1990 0.1194
Max 0.8455 4.2275 0.4211Min 0.0000 0.0000 0.0000SA 0.2122 1.0610 0.1057
Max 0.5595 2.7975 0.2786Min 0.0000 0.0000 0.0000SA 0.2264 1.1320 0.1127
Max 0.8674 4.3370 0.4320Min 0.0000 0.0000 0.0000SA 0.1246 0.6230 0.0621
Max 0.3628 1.8140 0.1807Min 0.0412 0.2060 0.0205SA 0.1321 0.6605 0.0658
Max 0.3709 1.8545 0.1847Min 0.0000 0.0000 0.0000SA 0.3542 1.7710 0.1764
Max 0.6071 3.0355 0.3023Min 0.1369 0.6845 0.0682SA 0.1825 0.9125 0.0909
Max 0.4175 2.0875 0.2079Min 0.0000 0.0000 0.0000SA 0.3582 1.7910 0.1784
Max 0.5893 2.9465 0.2935Min 0.1422 0.7110 0.0708SA 0.0162 0.0810 0.0081
Max 1.3680 6.8400 0.6813Min 0.0000 0.0000 0.0000SA 0.3703 1.8515 0.1844
Max 0.5931 2.9655 0.2954Min 0.1847 0.9235 0.0920SA 0.1840 0.9200 0.0916
Max 0.4926 2.4630 0.2453Min 0.0176 0.0880 0.0088SA 0.0261 0.1305 0.0130
Max 0.8865 4.4325 0.4415Min 0.0000 0.0000 0.0000SA 0.2002 1.0010 0.0997
Max 0.4936 2.4680 0.2458Min 0.0000 0.0000 0.0000SA 0.1366 0.6830 0.0680
Max 0.6374 3.1870 0.3174Min 0.0000 0.0000 0.0000SA 0.2856 1.4280 0.1422
Max 0.4569 2.2845 0.2275Min 0.0137 0.0685 0.0068SA 0.2622 1.3110 0.1306
Max 1.0150 5.0750 0.5055Min 0.0000 0.0000 0.0000SA 0.1479 0.7395 0.0737
Max 0.7586 3.7930 0.3778Min 0.0000 0.0000 0.0000SA 0.3193 1.5965 0.1590
Max 1.1830 5.9150 0.5891Min 0.0000 0.0000 0.0000SA 0.6020 3.0100 0.2998
Max 1.3630 6.8150 0.6788Min 0.0000 0.0000 0.0000
AP = Access PointSA = Spatial AverageMax = MaximumMin = Minimum
WD 1 General Office 2.1-3.0 12:32 ON
WD 1 General Office 2.1-3.0 15:33 OFF
WD 2 Staff Room 1.2-2.1 12:40 ON
WD 2 Staff Room 1.2-2.1 14:55 OFF
WD 3 Corridor outside storage room 1.8-2.7 12:48 ON
WD 3 Corridor outside storage room 1.8-2.7 15:53 OFF
WD 4 Library 2.1-3.0 12:56 ON
WD 4 Library 2.1-3.0 16:10 OFF
WD 5 Room 202 3.7-4.6 13:04 ON
WD 5 Room 202 3.7-4.6 16:18 OFF
WD 6 Room 117 4.0-6.0 13:14 ON
WD 6 Room 117 4.0-6.0 15:14 OFF
WD 7 Room 113 4.0-6.0 13:22 ON
WD 7 Room 113 4.0-6.0 15:06 OFF
WD 8 Room 108 4.0-6.0 13:30 ON
WD 8 Room 108 4.0-6.0 15:24 OFF
WD 9 Room 105 0.9-1.8 13:39 ON
WD 9 Room 105 0.9-1.8 15:42 OFF
WD 10 Room 116 4.0-6.0 13:48 ON
WD 11 Portable 1 0.3-1.2 13:58 ON
WD 10 Room 116 4.0-6.0 16:01 OFF
WD 12 Portable 7 0.3-1.2 16:40 OFF
WD 11 Portable 1 0.3-1.2 16:32 OFF
WD 12 Portable 7 0.3-1.2 14:06 ON