+ All Categories
Home > Documents > Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in...

Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in...

Date post: 27-Mar-2015
Category:
Upload: julian-sweeney
View: 214 times
Download: 1 times
Share this document with a friend
Popular Tags:
17
Electron detectors for HAPPEX2 and He •Design •Tests with high E electrons •PMT tests •Installation in HRS 4
Transcript
Page 1: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Electron detectors

for HAPPEX2 and He

•Design•Tests with high E electrons•PMT tests•Installation in HRS

4

Page 2: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Focal plane Detector

= 65 Mhz Dose = 2 MRad

Page 3: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Geometry

Two segments geometry for HAPPEX2

Detector stack overlaps elastic line

100 x 600 mm

Page 4: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Mechanics

Brass-quartz stack

Light guide Filter box

5 inches PMT

Page 5: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Fused quartz

•Radiation hard (Babar, CMS, E158)

•Optical polished (15-20 Angstr)

• 92% transmission in the range [350,550] tested with optical bench and with cosmic rays

Page 6: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Magnetic materials

M(Fe) -> specified ~ 1%

P(Fe) -> a) Bext at focal plane b) r

<A> Mean Moeller asymmetry -> numerical calculations.

FA = M(Fe) x P(Fe) x <A>

False asymmetry

Bext

Polarized electronsN+ N-

Fe

Fe

Page 7: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

-Bext <= 0.4 Gauss, r <=2

PFe < 10-5

-<AMoller> << 1 ppm

-Negligible contribution in the detector asymmetry.

Magnetic materials

Page 8: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Test with high energy electrons

h1 h2

Beam pipeMoeller dipole

Trigger scintillatorsHodoscope

Motorized rail

Selection of 2 e- of same energy

Page 9: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Resolution

•Ne/e- = 250

E/E = 18 %

Page 10: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Edge Effects

100 x600 mm

E/E=90%

E/E=20%

•Larger resolution balanced by extra statistics.•Need to correct for correlations between two segments for final result.

Real data to be analyzed

Page 11: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

PMT tests

•PMT burle 8854

•Need wide range in gain (10E3-106) :

• 2 bases available: - Happex - Resistive, low gain

Page 12: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

PMT test

Gain/IAnode correlations

Running conditions:

40 MHz, Filter 1/10 25 e/e I=1A with G=104

Preliminary results:

-Happex Base G/G =5% @ 1170V

-Resistive base: G/G= 2%@ 1420V

Page 13: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Installation in HRS

Horizontal rails

Page 14: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Installation in HRS

Page 15: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Installation in HRS

10 cm vertical gap between VDC and detector for scanners

Page 16: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

Detector Change

•Remove 1 segment in each spectro. ~4h

•Start installation of previously prepared “L” detector.

•Assembly of the 2 removed segments for the 2nd “L” ~8h

•Installation of the 2nd “L” ~6h

Could be done within 1 day Man power : 5

Page 17: Electron detectors for HAPPEX2 and He Design Tests with high E electrons PMT tests Installation in HRS 4.

WEB

Eveything at:

www-dapnia.cea.fr/Phys/Sphn/Parity/


Recommended