ELECTRONIC HID BALLASTS
C ommercial L ighting
Industrial Lighting
Street Lighting
Horticultural Lighting
2-6
7-11
12-13
14-15
2
Definition:Electronic ballasts for applications with low wattage MetalHalide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:Business lighting, office lighting, residential lighting, stagelighting, architectural lighting, decorative lighting, advertisinglighting, and more
Features and Benefits:• More stable operation and faster warm-up time• Fulham’s Electronic HID Ballasts extend lamp life up to 30%• Fulham’s low wattage, low frequency Electronic HID Ballasts compensate for input voltage fluctuations and
provide flicker-free operation• Lamp End-Of-Life (EOL) protection• Improved thermal performance
COMMERCIAL LIGHTING BALLASTS 20, 39, 70, 150 WATT 230V for MH/CDM Lamps
3
1
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH MOUNTING HEIGHT WEIGHT
110mm (4.37") 75mm (2.95") 32mm (1.26") 97.5mm (3.84") 63.5mm (2.50") 27.5mm (1.08") 0.28kg (0.62lb)
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH MOUNTING HEIGHT WEIGHT
164mm (6.45") 91mm (3.58") 38mm (1.50") 154mm (6.06") 68.5mm (2.7") 29.5mm (1.16") 0.56kg (1.23lb)
Compliances and Approvals:• ISO 9001
Performance Requirements:Input Voltage: 220-240V, 50/60HzVoltage Range: +/-10% of rated voltageTotal Harmonic Distortion (THD):
20W: <20%39W, 70W, 150W: <15%
Operating Frequency (Typical): 175HzCrest Factor: <1.5
Protections:• Lamp End-Of-Life (EOL) protection• Short circuit protection• Open circuit protection
Installation and Application Notes:• Ambient Temperature: -20°C through +55°C• Ignition pulse is 3-4kV max• Remote Mounting up to 1.5m• Power to lamp must be cycled (on/off/on) after replacing lamp• Ballast output will shut down after 30 minutes if lamp fails to ignite
COMMERCIAL LIGHTING BALLASTS 20, 39, 70, 150 WATT 230V for MH/CDM Lamps
CATALOG NUMBERINPUT VOLTS
(V)LINE CURRENT
(A)INPUT POWER
(W)MINIMUM
POWER FACTORTC MAX
(ºC)CASE &
WIRING DIAGRAM
20 1 H1-230-20HSC 220-240 0.11 25 ≥ 0.90 80 1
39 1 H2-230-35HSC 220-240 0.20 44 ≥ 0.95 80 1
70 1 H5-230-70HSC 220-240 0.35 78 ≥ 0.95 80 1
150 1 HXX-230-150-HBTCS 220-240 0.77 167 ≥ 0.95 80 2
LAMP DATA
WATTS NUMBER
(Please inquire about 50W and 100W models)
7563.5
97.5
32
27.5
1106.5
110
97.5
164
38
68.5
91
154
29.5
11.2
5
2
4
COMMERCIAL LIGHTING BALLASTS 20, 39, 50 WATT 120V for MH/CDM Lamps 20, 39, 50, 70, 100, 150, 175 WATT 120-277V for MH/CDM Lamps
Definition:Electronic ballasts for applications with low wattage Metal Halide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:Business lighting, office lighting, residential lighting, stagelighting, architectural lighting, decorative lighting, advertising lighting, and more
Features and Benefits:• More stable operation and faster warm-up time• Fulham’s Electronic HID Ballasts extend lamp life up to 30%• Fulham’s low wattage, low frequency Electronic HID Ballasts compensate for input voltage fluctuations and
provide flicker-free operation• Lamp End-Of-Life (EOL) protection• Improved thermal performance
CATALOGNUMBER
INPUT VOLTS(V)
LINE CURRENT(A)
INPUT POWER(W)
MINIMUMPOWER FACTOR
CASE &WIRING DIAGRAM
20 1 M156,C156,C175,M175 H1-120-22HSC 120 0.21 ≥ 0.98
39 1 M130,C179,C130 120 0.37 ≥ 0.98
50 1 M110,M1148 120 0.49 ≥ 0.98
LAMP DATA
WATTS NUMBER ANSI CODE
H3-120-39HSC
H4-120-50HSC
25
44
57
3
3
3
20 1 M156,C156,C175,M175 HXX-UNV-20-HBBCK 120-277 24 ≥ 0.90
39 1 M130,C179,C130 120-277 44 ≥ 0.90
50 1 M110,M1148 120-277 58 ≥ 0.90
70 1 C/M98,C/M139,C/M143 120-277 78 ≥ 0.90
100 1 M90,M140,M164 120-277 111 ≥ 0.95
150 1M102,M142,M/C142,
M81/M107 120-277 164 ≥ 0.95
175 1 M57,M152,M137 120-277 195 ≥ 0.95
H3-UNV-39HSC
H3-UNV-39HBC
HXX-UNV-50-HBSCK
HXX-UNV-50-HBBCK
H5-UNV-70HSC
H5-UNV-70HBC
H7-UNV-150HSC
H6-UNV-100HSC
H7-UNV-150HBC
H6-UNV-100HBC
H8-UNV-175HSC
H8-UNV-175HBC
0.10A/277V
0.21A/120V
0.18A/277V
0.37A/120V
0.21A/277V
0.48A/120V
0.29A/277V
0.66A/120V
0.42A/277V
0.97A/120V
0.61A/277V
1.54A/120V
0.71A/277V
1.78A/120V
5
4
5
4
5
4
5
4
5
4
7
6
7
6
5
COMMERCIAL LIGHTING BALLASTS 20, 39, 50 WATT 120V for MH/CDM Lamps 20, 39, 50, 70, 100, 150, 175 WATT 120-277V for MH/CDM Lamps
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
140mm (5.51") 91.5mm (3.60") 38mm (1.50") 131mm (5.16") 73.5mm (2.89") 0.59kg (1.30lb)
4
123
131
73.5
91.5
38
50.5
16 white
black
green
redblue
ACpower
1
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
95mm (3.74") 75mm (2.95") 30.5mm (1.20") 87mm (3.43") 65mm (2.56") 0.28kg (0.62lb)
3
white
black
green
redblue
ACpower65
87
8995
75
30.5
Compliances and Approvals:• cULus Listed (Outdoor Type 1)• FCC Part 18, for Non-Consumer Equipment• ISO 9001
Performance Requirements:Input Voltage: See chart on previous page for
120V and UNV 120-277V, 50/60Hz modelsVoltage Range: +/-10% of rated voltageTotal Harmonic Distortion (THD):
20W: <25%39W, 50W, 70W, 100W: <20%150W, 175W: <15%
Operating Frequency (Typical): 175HzCrest Factor: <1.5
Protections:• Lamp End-Of-Life (EOL) protection• Short circuit protection• Open circuit protection• Ignition failure protection• Thermal protection, UNV 120-277V models only
Installation and Application Notes:• Ambient Temperature: -20°C through +55°C• Ignition pulse is 3-4kV max• Remote Mounting up to 1.5m• Power to lamp must be cycled (on/off/on) after replacing lamp• Ballast output will shut down after 30 minutes if lamp fails to ignite
E328229
6
COMMERCIAL LIGHTING BALLASTS 20, 39, 50 WATT 120V for MH/CDM Lamps 20, 39, 50, 70, 100, 150, 175 WATT 120-277V for MH/CDM Lamps
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
164mm (6.46") 91.5mm (3.60") 38mm (1.50") 155mm (6.10") 73.5mm (2.89") 0.70kg (1.54lb)
7
147
155
73.5
91.5
38164
white
black
green
redblue
ACpower
6
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
164mm (6.46") 91.5mm (3.60") 38mm (1.50") 155mm (6.10") 73.5mm (2.89") 0.70kg (1.54lb)
147
155
73.5
91.5
38164
50.5
16white
black
green
redblue
ACpower
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
140mm (5.51") 91.5mm (3.60") 38mm (1.50") 131mm (5.16") 73.5mm (2.89") 0.59kg (1.30lb)
123
131
73.5
91.5
38
white
black
green
redblue
ACpower
5
7
INDUSTRIAL LIGHTING BALLASTS 250, 400 WATT 230V for MH/HPS Lamps
Definition:Electronic ballasts for applications with low wattage Metal Halide (MH) or High Pressure Sodium (HPS) lamps
Applications:Widely used in street lighting, stadium lighting, and industrial lighting
Features and Benefits:• Designed and manufactured with premium long-life components• Dimming options available, such as: 0-10V, preset program dimming, and step dimming• Communications protocol: Zigbee, DALI, and GSM• Easy initial installation or field replacement of magnetic ballasts• Fulham’s Electronic HID Ballasts compensate for input
voltage fluctuations and provide flicker-free operation
8
INDUSTRIAL LIGHTING BALLASTS 250, 400 WATT 230V for MH/HPS Lamps
CATALOG NUMBERINPUT VOLTS
(V)LINE CURRENT
(A)INPUT POWER
(W)MINIMUM
POWER FACTORTC MAX
(ºC)CASE &
WIRING DIAGRAM
250 1 HGE-230-250-JSSLK 220-240 1.23 275 ≥ 0.98 80 8
400 1 HGE-230-400-JSSLK 220-240 1.93 430 ≥ 0.98 80 8
LAMP DATA
WATTS NUMBER
Compliances and Approvals:• CE Marking• ISO 9001
Performance Requirements:Input Voltage: 220-240V, 50/60HzVoltage Range: +/-10% of rated voltageTotal Harmonic Distortion (THD): <10%Operating Frequency (Typical): 70-120kHzCrest Factor: <1.7
Protections:• Lamp End-Of-Life (EOL) protection• Short circuit protection• Open circuit protection• Ignition failure protection• Thermal protection
Installation and Application Notes:• Ambient Temperature: -30°C through +50°C• Ignition pulse is 5kV max• Remote Mounting up to 1.5m• Power to lamp must be cycled (on/off/on) after replacing lamp• Ballast output will shut down after 30 minutes if lamp fails to ignite
8
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
214mm (8.43") 98.5mm (3.88") 58.7mm (2.31") 202mm (7.95") 80mm (3.15") 1.3kg (2.87lb)
80 98.5
214
187
58.7
9
INDUSTRIAL LIGHTING BALLASTS 250, 400 WATT 230V for MH/CDM Lamps
CATALOG NUMBERINPUT VOLTS
(V)LINE CURRENT
(A)INPUT POWER
(W)MINIMUM
POWER FACTORTC MAX
(ºC)CASE &
WIRING DIAGRAM
250 1 HXE-230-250-HBSLS 220-240 1.23 275 ≥ 0.98 80 9
400 1 HXE-230-400-HBSLS 220-240 1.93 430 ≥ 0.98 80 9
LAMP DATA
WATTS NUMBER
Definition:Electronic ballasts for applications with low wattage MetalHalide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:
sculptured eaves, and more
Features and Benefits:• More stable operation and faster warm-up time• Fulham’s Electronic HID Ballasts extend lamp life up to 30%• Fulham’s low wattage, low frequency Electronic HID Ballasts compensate for input voltage fluctuations and
• Lamp End-Of-Life (EOL) protection• Improved thermal performance
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
240mm (9.44") 95mm (3.74") 65mm (2.56") 226mm (8.90") 40mm (1.57") 0.85kg (1.87lb)
9
65
6
4026
210
240226
95
10
INDUSTRIAL LIGHTING BALLASTS 140, 150 WATT 230V and 150 WATT 120-277V for use with: PHILIPS CosmoWhite 140W Lamps GE StreetWiseTM 150W Lamps SYLVANIA Urban White 140W Lamps
Definition: Electronic ballasts for applications with low wattage MetalHalide (MH) or Ceramic Metal Halide (CDM) lamps
Applications:Outdoor: Road lighting, port lighting, recreationalpark lighting, etc.Indoor: Large (highbay) retail outlets, warehouses,manufacturing facilities, etc.
Features and Benefits:• Designed for newer energy efficient lamps• Up to 118lm/W, perfect for OEM or retrofit applications• 2800K color temperature, Ra 66• Compact housing is easy to install and suitable for small lamp fixtures• Up to 20,000 hours lifetime• 50%-100% dimming• Waterproof rating: IP65• Improved thermal performance
11
INDUSTRIAL LIGHTING BALLASTS 140, 150 WATT 230V and 150 WATT 120-277V for use with: PHILIPS CosmoWhite 140W Lamps GE StreetWiseTM 150W Lamps SYLVANIA Urban White 140W Lamps
CATALOG NUMBERINPUT VOLTS
(V)LINE CURRENT
(A)INPUT POWER
(W)MINIMUM
POWER FACTORTC MAX
(ºC)CASE &
WIRING DIAGRAM
140 1 HXX-230-140-HSSLW 220-240 0.71 156 ≥ 0.95 80 10
150 1 HXE-230-150-JSSLW 220-240 0.77 167 ≥ 0.95 80 10
150 1 HXX-UNV-150-JSSLW 120-2771.54@120V
0.61@277V167 ≥ 0.95 80 10
LAMP DATA
WATTS NUMBER
10
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
182mm (7.17") 113mm (4.45") 41mm (1.61") 173mm (6.81") 70mm (2.76") 1.23kg (2.71lb)
160
41173182
70 113
Compliances and Approvals:• cULus Listed (Outdoor Type 1)• FCC Part 18, for Non-Consumer Equipment• ISO 9001: 2008
Performance Requirements:Input Voltage: See above chart for 230V and
UNV 120-277V, 50/60Hz modelsVoltage Range: +/-10% of rated voltageTotal Harmonic Distortion (THD):
220-240V 140W, 150W: <10%120-277V 150W: <15%
Operating Frequency (Typical): 175HzCrest Factor: <1.7
Protections:• Lamp End-Of-Life (EOL) protection• Short circuit protection• Open circuit protection• Ignition failure protection• Thermal protection
Installation and Application Notes:• Ambient Temperature: -30°C through +50°C• Ignition pulse is 5kV max• Remote Mounting up to 1.5m• Power to lamp must be cycled (on/off/on) after replacing lamp• Ballast output will shut down after 30 minutes if lamp fails to ignite
E328229
12
STREET LIGHTING BALLASTS 150 WATT 230V for MH/HPS Lamps
Around the globe, “green” technology is quickly becoming thepreferred choice for lighting due to its energy savingproperties and ROI potential. At Fulham, we are committed topromoting the adoption of cost efficient lighting technologiesin new fields. For example, we offer a complete EHID road lightingsolution that reduces power consumption by 40-60% comparedwith traditional street lights.
Features and Benefits:• Easily retrofit existing magnetic ballast applications• One Fulham Electronic HID ballast replaces a magnetic ballast, capacitor, and ignitor• More stable operation and faster warm-up time• Fulham’s Electronic HID Ballasts extend lamp life up to 30%• Fulham’s low wattage, low frequency Electronic HID Ballasts compensate for input voltage fluctuations and
provide flicker-free operation• Lamp End-Of-Life (EOL) protection• Improved thermal performance• Waterproof rating: IP65
Applications:Street lighting, port lighting, recreational park lighting, etc.
13
STREET LIGHTING BALLASTS 150 WATT 230V for MH/HPS Lamps
11
CASE LENGTH CASE WIDTH HEIGHT MOUNTING LENGTH MOUNTING WIDTH WEIGHT
182mm (7.17") 113mm (4.45") 41mm (1.61") 173mm (6.81") 70mm (2.76") 1.23kg (2.71lb)
Performance Requirements:Input Voltage: 220-240V, 50/60HzVoltage Range: +/-10% of rated voltageTotal Harmonic Distortion (THD): <15%Operating Frequency (Typical): 175HzCrest Factor: <1.7
Protections:• Lamp End-Of-Life (EOL) protection• Short circuit protection• Open circuit protection• Ignition failure protection• Thermal protection
Installation and Application Notes:• Ambient Temperature: -40°C through +50°C• Ignition pulse is 5kV max• Remote Mounting up to 1.5m• Power to lamp must be cycled (on/off/on) after replacing lamp• Ballast output will shutdown after 30 minutes if lamp fails to ignite
41
CATALOGNUMBER
INPUT VOLTS(V)
LINE CURRENT(A)
INPUT POWER(W)
MINIMUMPOWER FACTOR
TC MAX(ºC)
CASE & WIREDIAGRAM
150 1 MH&HPS HGE-230-150-JSSLW 220-240 0.77 167 ≥ 0.95 80 11
LAMP DATA
WATTS NUMBER SOURCE
14
HORTICULTURAL LIGHTING BALLASTS
15
CATALOG NUMBER NOTES APPROVAL INPUT VOLTAGE (V) INPUT CURRENT (A) INPUT POWER (W) LAMP TYPE (W/V)
HXX-277-1K-JGSHW 277 3.9 1050 1000/400
HXX-480-575-JGSCW 480 1.3 605 575/230
HXX-277-600-JGSHW 277 2.3 645 600/400
HXX-347-600-JGSHW 347 1.9 645 600/400
HXX-480-600-JGCUS UL 480 1.37 645 600/400
HPX-MLT-600-JGSLB UL 120-240 5.5/2.75 650/630 600/230
HPX-MLT-600-JGSLK UL 120-240 5.5/2.75 650/630 600/230
HPX-MLT-600-JGSLM13 step
dimming modelUL 120-240 5.5/2.75 650/630 600/230
HXX-MLT-600-JGSLM UL 120-240 5.5/2.75 650/630 600/230
HXX-277-750-JGSHW 277 2.91 790 750/400
HXX-347-750-JGCUS UL 347 2.31 790 750/400
HXX-277-1K-JGTUS UL 277 3.85 1050 1000/400
HXX-347-1K-JGTUS UL 347 3.07 1050 1000/400
HXX-347-1K-JGSHW 347 3.07 1050 1000/400
HXA-400-1K-JGSHW 400 2.61 1045 1000/400
HPX-MLT-1K-JGSLK UL 120-240 9.2/4.5 1110/1070 1000/400
HPX-MLT-1K-JGSLM13 step
dimming modelUL 120-240 9.2/4.5 1110/1070 1000/400
HXX-MLT-1K-JGSLB UL 120-240 9.2/4.5 1110/1070 1000/400
HXX-MLT-1K-JGSLM UL 120-240 9.2/4.5 1110/1070 1000/400
HXX-230-600-SGTLS 230 2.85 645 600/230
HXE-230-600-SGCUS 230 2.85 645 600/400
HXX-347-600-SGCUS 347 1.88 645 600/400
HXX-347-600-SGSHW 347 1.9 645 600/400
HXX-347-750-SGCUS 347 2.31 790 750/400
HME-400-750-SGCUS 400 1.98 790 750/400
HXE-400-750-SGTUS 400 1.98 790 750/400
HXE-400-750-SGCUS 400 1.98 790 750/400
HXE-400-1K-SGTUS 400 2.61 1045 1000/400
HXX-480-750-JGSCW 480 1.68 790 750/400
HXX-480-750-JGCUS UL 480 1.68 790 750/400
HXE-400-600-SGTUS 400 1.61 645 600/400
HXX-380-600-SGSHW 380 1.37 645 600/400
HPX-MLT-1K-JGSLG1 UL 120-240 9.2/4.5 1110/1070 1000/400
HXX-MLT-600-JGSLW UL 120-240 5.5/2.75 650/630 600/230
HXX-MLT-1K-JGSLW UL 120-240 9.2/4.5 1110/1070 1000/400
HORTICULTURAL LIGHTING BALLASTS
Fulham Latin America(Latin America)12705 S. Van Ness Avenue Hawthorne, CA 90250U.S.A.Tel: (407) 758-2564 [email protected]
Fulham Company GmbH (Europe)Karolinenstrasse 18D-58507 LüdenscheidGermanyHandelsregister Iserlohn: HR B 6286USt.-IdNr.: DE253959344Fon: +49 2351 4327416Fax: +49 2351 6567349Mobile: +49 [email protected]
Fulham Company Ltd. (Middle East)LOB-2, No 127 P.O. Box 261051Jebel Ali Free Zone, Dubai, UAETel: +9714-8873577Fax: [email protected]
Fulham (India) Pvt. Ltd.343, Kaliandas Udyog Bhavan Sadanand Tandel MargNear Century Bazar, PrabhadeviMumbai - 400025Tel: +91 22 66388775-9 [email protected] [email protected]
Fulham (India) Pvt. Ltd.Survey No. 26-3Village NarheTaluka Haveli, District: Pune 411041Tel: +91 20 24690703/4Fax: +91 20 [email protected]@fulham.com
Fulham Headquarters (USA)12705 S. Van Ness AvenueHawthorne, CA 90250Tel: (323) 599-5000Fax: (323) [email protected]
Fulham Company Ltd. (International) Unit 6, 6/F, Kowloon Plaza485 Castle Peak RoadCheung Sha Wan, KowloonHong KongTel: +852-2314-4801Fax: +852-2314-4186 [email protected]
Fulham Electronic Co. Ltd. (North China)No. 9 Xingchang Road, NanshaozhenChangping Science ParkBeijing 102200P.R. ChinaTel : +86-10-6073-5858Fax : [email protected]
Fulham Electronic Co. Ltd. (South China)Room 1402, Block D, The First PlaceWealth CentreNo. 200 Hongfu RoadThe South Dongguan City, Guangdong ProvinceP.R. ChinaTel: +0769-2202 7555Fax: +0769-2202 [email protected]
Fulham Electronic Co. Ltd. (Central China)Room 312-315, Xing YuanTechnology PlazaNo 418, Gui Ping RoadCaohe-Jing Hi-Tech ParkShanghai, P.R. ChinaPost Code: 200233Tel: +86-021-6495-2777Fax: [email protected]
Fulham Co., Inc. (Canada)24 Kicking Horse WayPort Moody, BC, Canada, V3H 0G5Tel: (604) 288-2609Fax: (604) [email protected]
www.fulham.com/chinese