Energy/Enviro Monitor EM100
Built-in WEB analysisNot required to have any internet network connection or portal subscription fees to work.
This fully embedded design reduces the hassle for paying regular portal server fees and you actually own 100% of the data!
Built-in con�guration WEB based software gives power to the user to add/delete meters or sensors logged into the system. Systems con�guration is made easy.
From retail shops to o�ces to buildings, the EM100 energy and environment monitor gives you real-time WEB access to manage your energy and your facility
Modbus energy m
eters
Temperaturesensors
Analogsensorswith4-20 mA
Controller
EM100
3
Cloud
Description
Non-Subscription Based You own and store the data inside the unit, no internet needed
Real-time Monitoring No 10min or 30min delays! Data are displayed and refreshed in seconds
Non-PC Based Industrial unit operates upto 70°C conditions, operates outdoors
Equipment Control Design condition based formulas to turn ON/OFF equipment for energy savings
Customized Diagrams Users design their own "single-line" real time data diagrams
Outdoor Temperature
WaterFlow
Total Consumption
Pulse orOn/O�
AutomaticControl
IndoorAir Quality
HVACConsumption
Overusage
Analog wiredModbusEthernet
Link types
Core Strengths
Direct WEB ViewOptional Enerwise WEB Portal
4
Enterprise level CLOUD monitoring optionEM200's user owned portal platform provides cross site comparison for the entire enterprise.
CLOUD energy management system manages data from multiple stores and buildings for enterprise level comparison.
EM200 collects up to 300 x EM100 units located at various buildings and sites. Customized reports ready to give power for C-level and executives to make decisions across the entire corporation. EM200 is an optional unit to be used in conjunction with EM100 to acheive multi-site access.
To comply with ISO50001 as the corporate directive, advanced level energy manager EM200 delivers the platform for multi-site management
Transformer
LV switchboard LV switchboardEM200
LAN
Pulse water meter
Control room
HVAC Lighting Cold UPS
Lighting Machines
Service station
Car park lighting
Electric vehicle charging stationsCold Lighting Ovens
Battery charger
Lighting Cold
Switch board
Building 1 Building 2 Building 3 Building 4EM100 EM100 EM100 EM100
Analog wired
Modbus
Ethernet
Electric
Link types
Switch board Switch board Switch board
Advanced Server EM200
Advanced Server EM200
5
Voltage, Current, PF, Power, Energy, Reactive, Frequency, Harmonics, Demand, Alarms,Solar Inverter, Wind Turbine
Voltage, Current, PF, Power, Energy, Reactive, Frequency, Harmonics, Demand, Alarms,Solar Inverter, Wind Turbine
CORE FUNCTIONS EM100 Energy/Environment Logger
164mmX118mmX60mm
YES
HARDWARE
Operating System
Communications
Logging Frequency
256MB Non-Volitle Memory for Storage
ARM9
Embedded Linux
SOFTWARE AND WEB
24VDC
OTHER FUNCTIONS
1min/10min/15min
Advanced Measurements
Direct WEB Access
<5W
CLOUD WEB Access
CE EMC/LVD/FCC
Relay Output
Weight
IP
Mechanical
Modbus RTU, Modbus TCP, Customized Protocol
DIGITAL AND ANALOG I/O
Function
Operating Temperature
RoHS
Dimensions
Power Consumption
Certi�cations
-20°C to 70°C
Alarms
Basic Measurements
Digital Input
Analog Input 6 Analog Input
6 Digital Input
EM200Advanced Server
255mmX152mmX50mm
YES
2GB
Intel Atom N450 1.67Ghz
Linux
24VDC
10min/15min
<12W
CE EMC/LVD/FCC/UL
Modbus RTU, Modbus TCP, Customized Protocol
-10°C to 70°C
Up to 128 Analog Inputs with expansion unit
Up to 128 Digital Inputs with expansion unit
Up to 32 Digital Outputs with expansion unit
Power Supply
Memory
CPU
Power Alarms, Power Quality, I/O Alarms byEmail and WEB
Single Project Analysis
Multi-Project Analysis and Management
Power Alarms, Power Quality, I/O Alarms byEmail and WEB
SCADA Single Line Diagram
Multi-Project Analysis and Management
IP40
0.38kg
IP40
2.5kg
SPECIFICATION
EM100 with CT’s only EM100-Basic
EM100 with RS485 devices EM100-10CL
EM100 with RS485 devices EM100-50CL
EM200
Basic
10 Licenses
50 Licenses
Energy Cloud Server
Module for 8 x Relay Outputs
Module for 8 x Relay Outputs
EM200
Relay Output
Analog Input
Zigbee Extender
Split Core CT
EM-M-4069
EM-M-4017
EM-M-SZ02
EM-CT10A, 20A, 50A, 80A, 100A
Energy/Enviro Monitor Order References
6
Analog 4-20mAElectrical Panel
No PC needed for the systemNo internet required for data sending to CLOUDNo meters needed when used with CT's
Industrial unit with LCD for simple displayEM100
Extended CT Connection Max. 120Expansion modules help link up more electrical panel CT's together
Pulse Meter Connection Max. 6Wh pulses direct connection
RS485 Power Meter Connection Max. 50Daisy chain connection method forup to 50 devices maximum
Hybrid Power and Control ApplicationMonitoring of loads via RS485 or CTand relay out module shed loads based on conditions set by the user.Each relay output contact can control8 di�erent loads.
Zigbee Extender provide wireless conversionbetween devices.
CT Direct Connection Max. 6Split core 10A-50A CT's monitorelectrical panel’s single phase consumption
Digital Pulse
kWh Pulse Meters
RS485/Zigbee
RS485/ZigbeePower Meters
RS485/Zigbee
RS485/Zigbee
Relay Contact
Power Meters
Motor
LoadLighting
LoadProcess
Load
Energy Monitoring and Control Application Guide
Enerwise EM100 is the industry's leading built-in WEBcontroller without requiring to subscribe to any CLOUD portal services, it works stand-alone!
Direct CTConnection
RS485 PowerMeterConnection
ENERGY MONITORING AND CONTROL
7
EM100 let users de�ne the "unit" of measurement for each sensor type, de�ne and set boundary limits to data points for alarm and activate relay outputs upon customized conditions, all this without the need of PC or PLC software.
Comprehensive sensor application monitoring and control solution, without the cost of PC and without high cost PLC software
Various Types of Sensors
Sensor Direct Connection Max. 6±150mV, ±500mV, ±1V, ±5V, ±10V, 0-20mA, 4-20mA supported sensor types
Extended Sensor Connection Max. 120Expansion modules help link up more various sensors simultaneously
RS485
Sensors
Analog Input
RS485/Zigbee
Relay Contact
Equipment
Sensor Monitoring Guide
Any AnalogSensorsCompatible
1 MinuteRecording
Analog InputSensors
Analog InputRS485/Zigbee
Zigbee
CO2 CO
°C PM
RS485/Zigbee
Power Meter
SENSOR MONITORING AND CONTROL
CO2 CO
Sensor and Control ApplicationMonitoring of application speci�c sensors via analog input expander and relay out module operates equipment based on conditions set by the user.
Each relay output contact can control8 di�erent loads.
Zigbee Extender provides wireless conversion between devices.
Wireless Sensor ConnectionWireless Zigbee modules convert RS485 into Zigbee allowing easiercon�guration
APPLICATION EXAMPLES
Fish Farm Water Quality Monitoring
Fish farms with automatic equipment control
Factory Energy Monitoring and Load Shedding
Fishes are extreme valuable assets to a �sh farm so that water quality must be constantly monitored. pH, O2, °C, Salinity sensors input into EM100 to provide minute to minute monitoring and min/max monitoring, alerting the operator of abnormality. Electric current monitoring of motor pumps detect if there are critical equipment failures in the farm.
Aerator, Pumps or Medicine switches can be automatically programmed to activate upon pre-set conditions.
Power meters measure the critical process loads of a factory and passes power consumption data such as PF, kWh, THD to EM100 via RS485 communication lines. EM100’s 2nd RS485 port connects to relay output module that used to do load shedding upon certain customized energy consumption conditions.
Integrate factory pollution sensors to detect dangerous substances released into the environment.
RS485/Zigbee
Relay Contact
RS485/Zigbee Analog Input
Pond 3Pond 2Pond 1
pH, O2, °C pH, O2, °C pH, O2, °C
Aerator
Water Pump
Fan
Heater
1. Water Pump Failure2. pH Problem
Alert
8
RS485/Zigbee
RS485/Zigbee
Relay Contact
RS485/Zigbee
Load Shed
Poisonous Gas orWater Pollution Sensor
AlertOver Pollution
Process 1 Process 2 Process 3
9
Chiller E�ciency Monitoring
Chiller plants are an essential part of the building especially in warmer climates. It consumes a large amount of energy for a building, therefore monitoring COP (coe�cient of performance) is critical.
Non-intrusive sensors such as �ow rate, water temperature IN/OUT can be connected to EM100 to calculate performance factors. Monitoring chiller load power meter data gives user the INPUT kW data for the performance calculation and also to understand energy used for di�erent chillers. When a chiller performs irregularly, customized alarms will be sent to the facilities manager.
Hospital Indoor Air Quality Monitoring
APPLICATION EXAMPLES
RS485/Zigbee
AlertCOP E�ciency Problem
Relay Contact
RS485/ZigbeeAnalog Input
RS485/Zigbee
Chiller
Flow Temp IN Temp OUT
Chiller Input Power
ChillerControl
RS485/ZigbeeRelay Contact
RS485/Zigbee
RS485/Zigbee
Floor 2Floor 1
Air VentilationControl
AlertAir Quality Poor
CO2 COPM CO2 COPM
Floor 1 PowerConsumption
Floor 2 PowerConsumption
PM2.5, CO2, Ozone, °C are monitored at ICU facilities in hospitals, ensuring good air circulation and preventing air-born diseases.
Air quality sensors monitor situations for each critical hall, then controls air ventilation equipment when air quality is poor.
10
SPECIAL KEY FEATURES
Automatic Control
Over Energy Use Alerts
1 Min Sensor Recordings
Users can de�ne a "warning" and "over" kWh energy limit for each category of loads. For example, when the lighting load kWh is reached, alarms and emails can be sent to alert the operator that lights were not turned o� after o�ce hours. Both "warning" and "over" limits can be set for all loads.
This function give power to the user for true energy savings action, not only noti�cation after the event.
EM100 can record sensor inputs from air and water/soil quality data, temperature data or electric current data every single 1 minute intervals. The function gives power to the user to see quick �uctuations of the environment and troubleshoots in detail.
Min, Max and Avg are recorded with time stamp.
The innovative formula function let users de�ne any conditions to turn ON/OFF equipment such as lights, fan, heating or air pumps via the relay output module. Pulse modulation or direct ON/OFF supported.
Since we are not operated using a portal system, the EM100 works like its own control unit and does not depend on the network status of EM100, it is basically a built-in controller.
Customizable Real-time Diagrams
Real-time diagrams or single-line diagrams can be fullycustomized via WEB settings to place various numericobjects on a single real-time display page. Numericobjects can be linked by users to any sensor or energydata or even calculated data from formulas.
Basically any application screens can be tailored to yourneeds, EM100 is not only limited to energy dashboard.
11
SPECIAL KEY FEATURES
Built-in WEB+CONTROL Technology
Energy Categorization
Creating Virtual Loads
Creating Alarms with Formulas
Formulas are a �exible way for the operator to de�ne alarm by email conditions or relay output conditions for a speci�c application. Almost all parameters read by power meters, sensors and time can be used as formula conditions.
To determine if lights are ON for Saturday, simply:(CT001.I > 0) AND (Day(time) = 6)
Users can self-de�ne various di�erent categories of energy, for example: Lighting, OutdoorLighting, Process1, Motor or HVAC. Simply assign the meter or CT into any of the user de�ned categories to create reports and benchmarks. 4 di�erent layers of categories can be set and �ltered.
Under each of these categories, the operator de�nes the occupancy, target kWh, limit kWh, area, etc properties for analysis.
No budget to install meters in every location? What about creating a virtual load by entering the kW rating of the load and the estimated running time. Or simply use formulas in our formula function to estimate this virtual load by another load that already has actual metering data.
EM100 does not depend on the PORTAL to run! It operates as a stand-alone controller unit, which means the web display and control functions are real-time! No dependency on internet networks, no security concerns for sharing critical data to another 3rd party company.
The operator owns the data!
Energy and Environment Monitoring and Control
Enerwise Solutions Ltd.
EM100/EM200 generates energy reports based on the new ISO50001 energy standards, grouping by shifts, days of week, ISO category types and applications.
Enerwise Solutions is a developer and manufacturer of energy management solutions for building energy management solutions, wind and solar power energy management systems.
03-2015
© 2015 - Enerwise Solutions Ltd. - All rights reserved
Email: [email protected]://www.enerwise.asia
Managing Your Energy Wise Represented by:
Dimensions (EM100)
Energy Management System
EM100www.enerwise.asiamanaging your energy wise