+ All Categories
Home > Documents > EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

Date post: 28-Mar-2016
Category:
Upload: jonathan-robins
View: 236 times
Download: 4 times
Share this document with a friend
Description:
eSHINE™ Flood Lamps Technical Data The eSHINE™ SOLAR FLOOD LED LIGHT and area luminaire provides uncompromising optical performance and outstanding versatility for a wide array of area and roadway applications. The eSHINE™ FLOOD delivers illumination and uniformity to meet a variety of worldwide standards for walkways, parking lots, roadway crossings, building areas, and any security lighting application.
Popular Tags:
8
eSHINEFlood Lamps Technical Data The eSHINE™ SOLAR FLOOD LED LIGHT and area luminaire provides uncompromising optical performance and outstanding versatility for a wide array of area and roadway applications. The eSHINE™ FLOOD delivers illumination and uniformity to meet a variety of worldwide standards for walkways, parking lots, roadway crossings, building areas, and any security lighting application.
Transcript
Page 1: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

eSHINE™ Flood Lamps Technical Data

The eSHINE™ SOLAR FLOOD LED LIGHT and area luminaire provides uncompromising optical performance and outstanding versatility for a wide array of area and roadway applications. The eSHINE™ FLOOD delivers illumination and uniformity to meet a variety of worldwide standards for walkways, parking lots, roadway crossings, building areas, and any security lighting application.

Page 2: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

General Information Construction Die-cast aluminum bottom and top sections are mechanically joined to the extruded heat sink mid-section. The advanced heat sink extrusion allows for a variety of lengths to suit any luminaire wattage we manufacture. Our unique construction allows for passive cooling and natural cleaning of the extruded heat sink, ensuring thermal management control with reliable operation at 45-50°C high ambient conditions. Stainless steel fasteners and hinging base section allow access to electrical components for installation and maintenance. Optics Full Cut Type III eSHINE™ Optics are precisely designed to shape the distribution thereby maximizing efficiency and application spacing. eSHINE™ Optics are engineered from PMMA thus maximizing light transmission. Longitudinal and overall uniformity has been accurately developed to meet global lighting standards.

LEDs A calculated L70 value of 250,000 + hours based on in-situ testing, LM-79 data and LM-80 data from the LED manufacturer Electrical LED drivers mount to die-cast aluminum back casting for optimal heat sinking and operation efficiency. Standard driver input 90-528 Volts AC with an IP 67 rating and with diming function available to optimize lighting control. DC powered drivers are also available. Mounting The eSHINE™ high powered FACADE lights come complete with wall or pole mounting bracket which incorporates a full adjustable tilt angle. Easy to adjust and position to reduce installation time. Finish Cast components and arm finished in polyester powder coat paint. Standard colors include grey and white - Other RAL colors are available including color match options.

Standard Model Details

ModelPerformance

(5500K - 8000K)

Premium

(4000K - 5500K)Optic B U G IP Rating Warranty

EFL-L24-NNN-XPG-65-D3-PG-V1 2327 3122 Type II 1 1 1 IP66 5-10 Yrs

EFL-L40-NNN-XPG-65-D3-PG-V1 3646 4892 Type II 1 0 1 IP66 5-10 Yrs

EFL-L64-NNN-XPG-65-D3-PG-V1 6298 8450 Type II 2 1 1 IP66 5-10 Yrs

EFL-L72-NNN-XPG-65-D3-PG-V1 7112 9542 Type II 2 1 1 IP66 5-10 Yrs

EFL-L80-NNN-XPG-65-D3-PG-V1 7706 10339* Type II 2 1 1 IP66 5-10 Yrs

NNN represents driver Current

*Geographical and run time considerations

Drive Current = 350ma Drive Current = 525ma

Page 3: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

Photometric Detail

EFL-L80-350 – 11Ft Setback

LCS TABLE

BUG RATING B2 - U0 - G1

FORWARD LIGHT LUMENS LUMENS %

LOW(0-30): 1,238.0 16%

MEDIUM(30-60): 3,065.4 39.7%

HIGH(60-80): 798.0 10.3%

VERY HIGH(80-90): 40.5 0.5%

BACK LIGHT

LOW(0-30): 709.3 9.2%

MEDIUM(30-60): 1,345.6 17.4%

HIGH(60-80): 490.0 6.3%

VERY HIGH(80-90): 30.6 0.4%

UPLIGHT

LOW(90-100): 0 0%

HIGH(100-180): 0 0%

TRAPPED LIGHT: 0 0%

Page 4: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

Physical Characteristics

(in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lb) (Kg)

EFL-L24-350 10.63 270 5.12 130 2.76 70 2.76 70 14.96 380 12.40 315 4.80 122 Bracket Bracket 19.98 9KG

EFL-L40-350 10.63 270 5.12 130 2.76 70 2.76 70 14.96 380 12.40 315 4.80 122 Bracket Bracket 19.98 9KG

EFL-L64-350 14.72 374 9.21 234 2.76 70 2.76 70 14.96 380 12.40 315 4.80 122 Bracket Bracket 24.42 11KG

EFL-L72-350 18.82 478 13.31 338 2.76 70 2.76 70 14.96 380 12.40 315 4.80 122 Bracket Bracket 28.86 13KG

EFL-L80-350 14.72 374 9.21 234 2.76 70 2.76 70 14.96 380 12.40 315 4.80 122 Bracket Bracket 24.42 11KG

E F G Mount WeightModel No.

A B C D

FL-SCB Standard ceiling bracket

* Project specific mounting options available

FLOOD

Mounting Options

Page 5: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

Installation Details

1. Wall and Ceiling attachment system – Allows for fast and easy installation in any surface mounted application. Plate option for single rod hanging available.

2. IP67 LED Driver - UL Listed LED Driver mounted to the back of the heat sink out of view at any installation angle (see LED Driver details below for further details and voltage options available).

3. Advanced Optic Type IV distribution - Type IV allows the lighting design grid to integrate

easily with the other eSHINE™ lamps installed to reduce the amount of lamps required.

4. IP rated Field Wiring terminal strip - Easy termination of field wiring and earth connections.

5. Adjustable tilt for advanced installation options.

Page 6: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

eSHINE Product Family Model Numbers

eSHINE-Product

Family

No. LED's Driver

type

LED

type

Optic Distribution Finish Voltage type

ES Street L10=10 LEDs 350ma XPE 65⁰ D1=Type IPG=

Metallic

V1=90 - 305

VAC

EA- Area L20=20 LEDs 525ma XPG 85⁰ D2=Type II PW= White V2=480 VAC

EC-Canopy L30=30 LEDs 700ma C535A V=Variable D3=Type III PB= Bronze V3- Dimming

EFL - Flood L40=40 LEDs 1050ma C503D D4=Type IV PB=black V4=12 VDC

EF - Façade L50=50 LEDs D=Direct D5=Type V V5= 24 VDC

EB-Bol lard L60= 60 LEDs

ES-Shelter L70= 70 LEDsMounting options- See mounting details on data sheets

ER-Reflect L80= 80LEDsOther body colors available upon request

EU-Up L100- 100 LEDsOrdering information- Example. eS-L40-350-XPG-65-D2-PG-V5

EBA- Banner L120=120 LED's

EFH- FlashMC=Multi Chip

LEDs

ELB- Low Bay

EEP - Path

ENAV- Nav

Page 7: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

Additional Information

Warranty 5 years LEDs

5 Years Driver

10 Years Mold/extrusion

Lamp attachments Pole, wall, soffit, Bracket and Hanging rod mounting options available

Finishes RAL Colors to 50 microns

Extrusions & molds 6063 Aluminum

Optics Poly-Meth-methyl-acrylic-Optical Grade PMMA PC

Average transmittance in visible spectrum 400nm~700nm> 90%

Advanced Uniformity design with the Optical performance distributing light

accurately , maximizing spacing between poles

LED Driver • High Efficiency (Up to 92%)

• Active Power Factor Correction (0.99 Typical)

• Constant Current Output

• Lightning Protection

• All-Round Protection: OVP, SCP, OTP

• Waterproof (IP67)

• Comply With UL8750 & EN61347 Safety Regulations

• Comply With ANSI/IEEE C62.41, Class A Operation

• 90-528 VAC single phase

• 480 VAC SWER 2 hot wire earth return

• 12 and 24 VDC drivers available for most Wattages

LEDs The XLamp XP-G LED is capable of up to 493 lumens at 92 lumens per watt when driven at 1.5 A. XLamp XP-G LEDs set the new standard for light output and efficacy in single-die LEDs, extending the leadership of Cree’s lighting-Optic XLamp XP family and giving lighting designers a wide range of price and performance options that all share a common footprint. Features • ANSI-compatible chromaticity bins • RoHS and REACH-compliant • UL-recognized component • Unlimited floor life at <= 30 degrees C/85% RH • Electrically-isolated thermal path

Page 8: EMBER LED - eSHINE SOLAR LED FLOOD LIGHT

Controller MPPT Advanced- maximum power point tracking controller with over 90 days data logging

Dusk till dawn or on at any set time down to 1 minute after nightfall

Split time operation to have lights come on for a set time and then back on before dawn

MPPT Standard- maximum power point tracking controller with over 90 days data logging

Low voltage disconnect

Battery over charge protection

Surge protection

Battery Sealed maintenance free GEL type

4 days autonomy back up

5 years warranty ( This will depend on location)

Solar Panel 25 Year limited warranty on output power, 5 years on workmanship

High efficiency cells

Advanced EVA encapsulation system


Recommended