26
EMC Accessories Catalog Transducers and Accessories HP 11966 Series Antennas HP 11967 Series Conducted EMC Accessories HP 11968 Series EMC Positioning Accessories A fully equipped electromagnetic compatibility (EMC) laboratory requires a wide variety of instruments, equipment, and accessories to allow measure- ments to be made accurately and efficiently. On a smaller scale, design engineers and test technicians also need an assortment of measurement tools to evaluate their product designs prior to formal EMC compliance testing. This EMC accessories catalog helps you quickly find the equipment you need to make your EMC measurements. You’ll find a large selection of antennas, current probes, LISNs, cables, tripods, preamplifiers, and other accessories. Each is designed to enhance your EMC measurement capabilities and provide lasting value. Hewlett-Packard is continually expanding its line of EMC accessories to ensure the most comprehensive line of EMC test equipment available. Be sure to check with your local HP sales representative if you need an item that is not listed in this product overview.
Transcript

EMC AccessoriesCatalog

Transducers and Accessories

HP 11966 Series Antennas

HP 11967 Series ConductedEMC Accessories

HP 11968 Series EMCPositioning Accessories

A fully equipped electromagneticcompatibility (EMC) laboratoryrequires a wide variety ofinstruments, equipment, andaccessories to allow measure-ments to be made accuratelyand efficiently. On a smallerscale, design engineers and testtechnicians also need anassortment of measurementtools to evaluate their productdesigns prior to formal EMCcompliance testing.

This EMC accessories cataloghelps you quickly find theequipment you need to makeyour EMC measurements.

You’ll find a large selection ofantennas, current probes, LISNs,cables, tripods, preamplifiers,and other accessories. Each isdesigned to enhance your EMCmeasurement capabilities andprovide lasting value.

Hewlett-Packard is continuallyexpanding its line of EMCaccessories to ensure the mostcomprehensive line of EMC testequipment available. Be sure tocheck with your local HP salesrepresentative if you need anitem that is not listed in thisproduct overview.

2

Table of Contents

Listed by Hewlett-Packard Model Number

Model Number Description Page

HP 11500A Six foot RG-214U Cable with Type-N Connector 20HP 11500F 150 cm Cable (APC 3.5 Male Connectors) 20HP 11940A Close Field Probe 30 MHz to 1 GHz 22HP 11941A Close Field Probe 9 KHz to 30 MHz 22HP 11945A Close Field Probe Set 22HP 11947A Transient Limiter 20HP 11955A Biconical Antenna 7HP 11956A Log Periodic Antenna 8HP 11960A EMC Preselector 24HP 11961A EMI Measurement Software 19HP 11966A Active Magnetic Loop Antenna 6HP 11966A K12 Passive Loop Set 10HP 11966A K24 Biconical Antenna 20 MHz to 300 MHz (2000 Watts) 7HP 11966A K30 Passive Rod Antenna 10HP 11966A K38 Biconical Antenna 30 MHz to 300 MHz (300 Watts) 7HP 11966A K40 Royce Field Site Source 10HP 11966A K47 Five Meter Cable (APC 3.5 Male Connector) 20HP 11966A K48 Ten Meter Cable (APC 3.5 Male Connector) 20HP 11966B Active Monopole Antenna 6HP 11966C Biconical Antenna 30 MHz to 300 MHz 7HP 11966D Log-Periodic Antenna 200 MHz to 1 GHz 8HP 11966E Double-Ridged Waveguide Horn Antenna 1 GHz to 18 GHz 9HP 11966F Conical Log Spiral Antenna 200 MHz to 1 GHz 11HP 11966G Conical Log Spiral Antenna 1 GHz to 10 GHz 11HP 11966H Dipole Antenna Set 28 MHz to 1000 MHz 12HP 11966I Horn Antenna 200 MHz to 2 GHz 9HP 11966J Horn Antenna 18 GHz to 40 GHz 9HP 11966K Magnetic Field Pickup Coil 20 Hz to 50 kHz 13HP 11966L Coaxial Cable 10 Meter Type-N 20HP 11966M Coaxial Cable 10 Meter BNC 20HP 11966N Log Periodic Antenna 200 MHz to 5 GHz 8HP 11966P Broadband Antenna 14HP 11967A K05 Absorbing Clamp 5HP 11967A K06 Cavity Rejection Networks 13HP 11967A K23 Bridged-T Rejection Networks 13HP 11967A Current Probe 15 kHz to 50 MHz 4HP 11967B Current Probe 20 Hz to 2 MHz 4HP 11967D 10A Line Impedance Stabilization Network 5HP 11967E 25A Line Impedance Stabilization Network 5HP 11968A K07 Shielded Room Kit 19HP 11968B Manual Antenna Positioning Mast 17HP 11968C Antenna Tripod 23HP 11968E Manual Equipment Test Turntable 18HP 8447F H64 Dual Preamplifier 0.1 to 1300 MHz 21HP 8449B Microwave Preamplifier 1 GHz to 26.5 GHz 21HP 85650A Quasi-Peak Adapter 25HP 85685A RF Preselector 24HP 85876B Commercial Radiated EMI Software 19HP 85878A EMI Report Generator 190160-6683 10 µF Capacitor 48120-1840 122 Centimeter Coaxial Cable 2011729-60014 Low Noise Preamplifier 21

3

Recommended Transducers for Commercialand MIL-STD EMI Testing

10 Hz 100 Hz 1 KHz 10 KHz

9 KHz 30 MHz

100 KHz 1 MHz

Frequency Range

10 MHz 100 MHz 1 GHz 10 GHz 100 GHz

(conducted)CISPR, EN, FCC, VCCI, VDEuse LISN with Transient Limiter - HP 11967D/E or 11947A

(radiated)VDEuse Magnetic Loop Antenna - HP 11966A 30 MHz 300 MHz

CISPR Poweruse Absorbing Clamp - HP 11967A K05(radiated)CISPR, EN, FCC, VCCI, VDE use Biconical Antenna - HP 11966C, Tunable Dipole - HP 11966H, Broadband Antenna HP 11966P

200 MHz 1 GHz

200 MHz 5 GHz

(radiated) CISPR, EN, FCC, VCCI, VDEuse Log Periodic - HP 11966D, Tunable Dipole - HP 11966H, Broadband Antenna HP 11966P

(radiated)CISPR, EN, FCC, VCCI, VDEuse Log Periodic - HP 11966N

30 Hz 50 MHz

30 Hz 50 KHz

10 KHz 30 MHz

40 GHz

300 MHz

200 MHz

200 MHz

1 GHz

20 MHz

(conducted)MIL-STD 461A/B/Cuse Current Probes HP 11967A/B, 10 µF Capacitor 0160-6683MIL-STD 461Duse LISN HP 11967D/E

(radiated)MIL-STD 461Duse Magnetic Field Pickup - HP 11966K

(radiated)MIL-STD 461A/B/C/Duse Rod Antenna - HP 11966B

(radiated)MIL-STD 461A/B/C/Duse Biconical - HP 11966C

(radiated)MIL-STD 461Duse Log Periodic - HP 11966P

(radiated)MIL-STD 461A/B/C/Duse Horn Antenna - HP 11966l, Horn Antenna - HP 11966J, Horn Antenna - HP 11966E

MIL-STDTests

CommercialTests

4

HP 11967A Current ProbeThis current probe is designedfor MIL-STD 461A/B/C CE-03measurements of conductedemissions on power and has aconstant transfer impedance of0.5 Ω (±2 dB) from 50 kHz to 50 MHz.

Conducted EMI Accessories

Frequency Range 15 kHz - 50 MHzMax Primary Power 350 A, DC - 60 HzAperature Diameter 25 mm (1 in)Connector Type N female

HP 11967B Current ProbeThis current probe is designedfor MIL-STD 461A/B/C CE-01and 461D CE101 measurementsof conducted emissions onpower and interconnectingleads. The probe has a constanttransfer impedance of 0.3 Ω(±2 dB) from 2 kHz to 2 MHz.

Frequency Range 20 Hz - 2 MHzMax Primary Power 100 A, DC - 400 HzAperature Diameter 25 mm (1 in)ConnectorType N female

0160-6683 10 µF CapacitorMany MIL-STD 461A/B/Cconducted emissions test setupsrequire a 10 µF capacitor beplaced between each line beingtested and the metallic tabletopsurface where the test is beingmade.

Capacitance Value 10 µF ± 10%Maximum Voltage 600 VDC, 250 V at 400 HzMaximum Current 50AConnector Type 1/4-28 feed-thru stud

5

Conducted EMI Accessories

HP 11967D 10A Line ImpedanceStabilization NetworkThis V-network, two line, singlephase line impedancestabilization network (LISN)meets the requirements of theFCC, VDE, and the EuropeanNorms (ENs) for commercialconducted emissions testing. NEMA power outlet comesstandard with product.

Frequency Range 9 kHz - 30 MHzPower Source Frequency DC - 60 HzMaximum Current 10 AMaximum Voltage 460 VAC line-to-line

250 VAC line-to-groundNetwork Inductance 50 µH - 250 µHNetwork Impedance 50 ΩConnector Type BNC femaleOption 001 SCHUKO outletOption 002 British outlet

HP 11967E 25ALine ImpedanceStabilization NetworkThis LISN is a two line singlephase device. It has a standardNEMA power outlet adapter.

HP 11967A K05Absorbing ClampThe absorbing clamp is used inCISPR 14 based tests to measureinterference power levels oncables connected to electronicand electrical devices.

Frequency Range 9 kHz - 30 MHzPower Source Frequency DC - 60 HzMaximum Current 25 AMaximum Voltage 460 VAC line-to-line

250 VAC line-to-groundNetwork Inductance 30 µH - 250 µHNetwork Impedance 50 ΩConnector Type BNC femaleOption 001 SCHUKO outletOption 002 British outletOption 003 Australian outlet

Frequency Range 30 MHz - 1 GHzAperature Size 27 mmConnector Type BNC female

6

Antennas l

HP 11966A Active MagneticLoop AntennaThe HP 11966A active loopantenna was designed specificallyfor three-meter VDE 0871 LimitB magnetic-emissions testing. A built-in preamplifier in theantenna base matches the lowimpedance of the loop with the50 watt input of the EMI receiverand provides a consistent, linearantenna factor over the frequencyrange of the antenna. A built-insaturation indicator alerts theoperator to overload conditions.The standard unit is suppliedwith a 120 VAC/60 Hz batterycharger. Option 220 replaces thestandard battery charger with a220 VAC/50 Hz unit.

HP 11966B Active MonopoleAntennaThis broadband active rod E-fieldantenna has a preamplifierbuilt into its base. This designprovides sensitivity, highdynamic range, and a flatantenna factor, yet eliminatesthe need for manual tuning orbandswitching. A built-insaturation indicator alerts theoperator to overload conditions.The standard unit is suppliedwith a 120 VAC/60 Hz batterycharger. Option 220 replaces thestandard battery charger with a220 VAC/50 Hz unit.

Frequency Range 10 kHz - 30 MHzLoop Diameter 600 mm (23.6 inches)Battery Type Rechargeble, sealed

lead-acidImpedance 50 ΩConnector Type BNC femaleMounting Base (to attach unit to tripod)

1/4 inch x 20 female thread

Frequency Range 30 Hz - 50 MHzInternal Atten 10 and 30 dBSaturation Point 22 V/m (using 30 dB atten)Battery Type Rechargeble, sealed

lead-acidImpedance 50 ΩConnector Type BNC femaleMounting Base (to attach unit to tripod)

1/4 inch x 20 female thread

Frequency Typical Antenna Factor(MHz) (dB)

0.01 17.70.02 13.40.05 10.00.07 10.40.1 10.20.15 10.10.25 10.10.5 10.20.75 10.31 10.42 10.53 10.54 10.65 10.610 10.615 10.320 9.625 8.630 7.1

Frequency Typical Antenna Factor(MHz) (dB)

0.0001 5.30.0003 1.70.0005 1.20.0007 1.10.0009 1.00.001 1.10.003 0.90.005 0.80.007 0.90.009 0.60.01 1.00.03 0.70.05 0.60.07 0.50.09 0.50.1 0.60.3 0.50.5 0.50.7 0.50.9 0.61 0.63 1.45 1.67 1.99 2.220 2.950 9.6

1. All antennas sold by HP are individually calibrated. They include a calibration certificate showing actualperformance data. The antenna factors shown in this catalog are intended to show typical performance only.

7

Antennas 1

HP 11966A K24Biconical AntennaThe rugged balun design of thisantenna makes it especiallysuitable for susceptibility testswhere high input powers areneeded.

Frequency Range 20 MHz - 300 MHzMax Contin Power 2000VSWR (avg) 1.9 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

HP 11966A K38Biconical AntennaThis versatile antenna is usefulfor both emissions and immunitymeasurements and can handleup to 300 watts of continuouspower.

Frequency Range 30 MHz - 300 MHzMax Contin Power 300 WVSWR (avg) < 2.5 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

HP 11966A K24 HP 11966A K38

Frequency Antenna Factors(MHz) (dB)

20 11.5 —30 13.0 13.540 14.7 1550 12.2 12.760 10.1 10.470 8.9 8.980 8.0 8.590 8.9 8.8100 9.6 9.6110 11.3 11.3120 12.8 12.6130 14.5 14.1140 15.9 16.0150 16.5 16.6160 16.0 16.5170 15.3 15.6180 14.5 14.8190 14.5 14.5200 13.8 14.1210 14.0 14.1220 14.5 14.4230 15.8 15.8240 16.8 17.0250 18.3 18.9260 19.9 20.3270 21.4 22.0280 22.6 23.1290 20.9 21.0300 24.6 22.7

HP 11966C Biconical AntennaThis state-of-the-art antennauses ferrites in the balun andalong the feedline to eliminatecommon-mode currents.It employs a novel element-cagedesign that allows an extremelysmooth response curve.

Frequency Range 30 MHz - 300 MHzMax Contin Power 0.5 WVSWR (avg) < 1.8 : 1 (with 6 db pads)Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

Frequency Typical Antenna Factor(MHz) (dB)

30 19.040 17.950 13.260 9.070 6.680 7.690 9.2100 10.5110 12.0120 14.0130 16.3140 18.4150 19.4160 19 0170 18.3180 17.6190 17.0200 16.7210 17.0220 17.4230 18.2240 19.1250 20.4260 22.4270 24.5280 25.5290 25.0300 24.9

1. All antennas sold by HP are individually calibrated except for HP 11955A andHP 11956A which have typical antenna factors. They include a calibration certificateshowing actual performance data. The antenna factors shown in this catalog areintended to show typical performance only.

HP 11955ABiconical AntennaThis economical antenna hastypical antenna factors.

Frequency Range 30 MHz - 300 MHzMax Contin Power 0.5 WVSWR (avg) 1.8 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

8

Antennas 1

HP 11966DLog Periodic AntennaThe HP 11966D is a broadband,relatively high-gain antennathat is suitable for bothcommercial and military EMCmeasurements.

Frequency Range 200 MHz - 1 GHzMax Contin Power 1000 WVSWR (avg) < 2 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

Frequency Typical Antenna Factor(MHz) (dB)

200 17 0225 14.8250 14 3275 14.9300 16.8325 17.5350 18.7375 17.5400 17.1425 17.4450 18.4475 19.8500 20.5525 19.2550 19.5575 19.7600 20.7625 21.5650 22.0675 21.6700 21.6725 22.1750 22.7775 22.8800 22.6825 22.6850 23.2875 24.0900 24.4925 24.3950 23.9975 24.41000 25.1

HP 11966NLog Periodic AntennaThis antenna has similar performance characteristics to the HP 11966D, but has an extended frequency range to 5 GHz.This is useful for some of the new commerical test requirements,such as FCC part 15 limits for high-speed unintentionalradiators, which now extend beyond 1 GHz.

Frequency Range 200 MHz - 5 GHzMax Contin Power 80 WVSWR (avg) 2 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

Frequency Antenna Factor(GHz) (dB)

0.2 100.5 171.0 231.5 272.0 292.5 323.0 343.5 374.0 384.5 415.0 42

HP 11956ALog Periodic AntennaThis economical antenna hastypical antenna factors.

Frequency Range 200 MHz - 1 GHzVSWR (avg) < 2 : 1Impedance 50 ΩConnector Type Type-NMounting Base 1/4 inch x 20 female thread

1. All antennas sold by HP are individually calibrated. They include acalibration certificate showing actual performance data. The antenna factorsshown in this catalog are intended to show typical performance only.

9

HP 11966E Double RidgedWaveguide Horn AntennaThis antenna covers a verybroad frequency range andprovides excellent gain andVSWR characteristics. It issuitable for receiving andtransmitting signals and canhandle up to 300 watts of power.

Frequency Range 1 GHz - 18 GHzMaxi Contin Power 300 WVSWR (avg) < 1.5 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

Frequency Typical Antenna Factor(MHz) (dB)

1000 24.41500 25.72000 28.42500 29.43000 31.03500 32.24000 33.84500 33 05000 34.75500 35.46000 35.46500 35.77000 36.57500 37 88000 38.08500 38.19000 38.49500 38.410000 38.510500 38.611000 39.011500 39.312000 39.412500 39.013000 39.913500 41.314000 41.414500 41.315000 39.915500 37.516000 38.216500 39.817000 41.717500 44.618000 46.9

HP 11966I Horn AntennaThis horn covers the RF rangeand is very useful as a receivingantenna for MIL-STD emissionstests. Its high power handlingcapability also makes it anexcellent transmitting antennafor susceptibility/immunity tests.

Frequency Range 200 MHz - 2 GHzMax Contin Power 800 WVSWR (avg) 1.6 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

Frequency Antenna Factor(GHz) (dB)

0.2 110.4 140.6 180.8 191.0 221.2 231.4 251.6 261.8 252.0 32

HP 11966J Horn AntennaThe double-ridged design of thishorn enables it to cover twowaveguide bands with a singleantenna.

Frequency Range 18 GHz - 40 GHzMax Contin Power 50 WVSWR (avg) 1.6 : 1Impedance 50 ΩConnector Type K femaleMounting Base 1/4 inch x 20 female thread

Frequency Antenna Factor(GHz) (dB)

18 4520 4425 4630 4735 5040 46

Antennas l

1. All antennas sold by HP are individually calibrated. They include acalibration certificate showing actual performance data. The antenna factorsshown in this catalog are intended to show typical performance only.

10

Antennas 1

Frequency Range 1 kHz - 30 MHzMax Contin Power 300 WImpedance 50 ΩConnectorType N femaleMounting Base 1/4 inch x 20 female thread

HP 11966A K30Passive Rod AntennaThe HP 11966A K30 is a passive broadband electric field monopoletransmitting antenna that has a frequency range of 1 kHz to 30 MHz. It features manual band switching between 0.001 to 5 MHz, and 5 to 30 MHz.

Frequency Range 1 kHz - 30 MHzConnector Type BNC on antenna 1

N female on antenna 2Sensitivity (ant 1) -29 dB µA/M (@ 1 MHz)Dynamic Range (ant 1) 116 dB @ 1 MHzMax Power (ant 2) 1 kWMounting Base 1/4 inch x 20 female thread

HP 11966A K12Passive Loop SetThe HP 11966A K12 passive loop set is designed for measuringshielding effectiveness. It consists of two loop antennas. The first onehas a built-in, battery operated preamplifier. The preamplifierprovides greater sensitivity and uniform antenna factors. The secondantenna is band-selectable in four bands and can accept up to 1 kWinput power.

HP 11966A K40Royce Field Site SourceThe HP 11966A K40 Royce field site source generates radiatedemissions of a consistent frequency and amplitude. The emissionsare used to create a base standard for a specific test site. The sitecould be either an indoor or outdoor facility. The Royce source isused in place of a DUT and a normal radiated emissions test is thenperformed. These test results become the bases by which future sitetests are compared. Deviation from the base data could indicate testsite problems. Frequency range: 10 MHz to 600 MHz.

1. All antennas sold by HP are individually calibrated. They include a calibrationcertificate showing actual performance data. The antenna factors shown in thiscatalog are intended to show typical performance only.

11

1. All antennas sold by HP are individually calibrated. They include a calibrationcertificate showing actual performance data. The antenna factors shown in thiscatalog are intended to show typical performance only.

Antennas l

HP 11966F ConicalLog Spiral AntennaThe HP 11966F was designedspecifically for MIL-STD 461A/B/Cradiated measurements. Because itis circularly polarized, it can receivefields in any polarity. Thiseliminates the need to duplicatethe measurement in bothhorizontal and vertical orientationto find maximum emissions.

Frequency Range 200 MHz - 1 GHzMax Contin Power 100 WVSWR (avg) < 2.5 : 1Impedance 50 ΩConnector Type N femaleMounting Base 1/4 inch x 20 female thread

Frequency Typical Antenna Factor(MHz) (dB)

200 17.0225 14.8250 14.3275 14.9300 16.8325 17.5350 18.7375 17.5400 17.1425 17.4450 18.4475 19.8500 20.5525 19.2550 19.5575 19.7600 20.7625 21.5650 22.0675 21.6700 21.6725 22.1750 22.7775 22.8800 22.6825 22.6850 23.2875 24.0900 24.4925 24.3950 23.9975 24.41000 25.1

Frequency Typical Antenna Factor(MHz) (dB)

1000 27.12000 33.33000 36.14000 40.45000 42.36000 43.37000 45.18000 46.19000 47.910000 49.9

Frequency Range 1 GHz - 10 GHzMax Contin Power 50 WVSWR (avg) < 2 : 1Impedance 50 ΩConnector Type N female

HP 11966G ConicalLog Spiral AntennaThis antenna is similar to theHP 11966F, but it is designed to operate in the 1 to 10 GHzregion. It is ideally suited forMIL-STD 461A/B/C microwaveradiated measurements.

12

Antennas l

HP 11966H DipoleAntenna SetThe HP 11966H dipole antennaset consists of four baluns withadjustable and removablestainless steel elements. Theycan be used for site-attenuationmeasurements as well as forgeneral EMI testing. Includedare a mounting clamp, five-metermeasuring tape, ruler andstorage case.

Frequency Range 28 MHz -1 GHzBalun 1: 28 - 60 MHzBalun 2: 60 - 140 MHzBalun 3: 140 - 400 MHzBalun 4: 400 - 1000 MHz

Max Contin Power 20 WVSWR (avg) < 1.6 : 1Impedance 50 ΩConnectorType N female

Frequency Typical Antenna Factor(MHz) (dB)

30 0.240 1.250 3.060 4.9

Frequency Typical Antenna Factor(MHz) (dB)

60 4.270 5.180 6.390 8.3100 9.3110 10.4120 11.6130 11.0140 12.2

Frequency Typical Antenna Factor(MHz) (dB)

140 13.0180 13.7220 15.7260 17.7300 18.3340 18.8400 21.5

Frequency Typical Antenna Factor(MHz) (dB)

400 22.0500 24.6600 24.7700 25.8800 26.8900 28.41000 28.7

1. All antennas sold by HP are individually calibrated. They include a calibrationcertificate showing actual performance data. The antenna factors shown in thiscatalog are intended to show typical performance only.

13

Antennasl

HP 11966K MagneticField Pickup CoilThis antenna is designedspecifically for MIL-STD 462RE-01 and RE-101 measurements.The loop is constructed ofaluminum and has 36 turns of 7 x 41 Litz wire for lowerinductance.

Frequency Range 20 Hz - 50 kHzLoop Diameter 133 mm (5.25 inches)Connector Type BNC female

Frequency Typical Antenna Factor(kHz) (dB)

0.02 840.04 780.06 740.08 720.1 700.2 640.4 580.6 540.8 521.0 502.0 444.0 386.0 348.0 3210.0 3020.0 2540.0 2450.0 23

HP 11967A K06 CavityRejection NetworksThe HP 11967A K06 cavityrejection networks have acontinuously tunable frequencyrange from 1 GHz to 10 GHz infour bands. They also offer lowinsertion loss with very sharpresonances.

Frequency Range 1 GHz - 10 GHzRejection 80 dB minimum at tuned

frequencyInsertion Loss 5 dB or less (avg)Bandwidth 0.2 % of tuned frequency

at 20 dB point and 0.4 % at 10 dB point

Connector Type N female

HP 11967A K23 Bridged-TRejection NetworksThe HP 11967A K23 bridged-Trejection networks are designedfor radio frequency interferencetesting according to variousmilitary specifications. The threenetworks are passive and contin-uously tunable over the 10 kHzto 1 GHz frequency range.

Frequency Range Network 1: 10 kHz - 100 MHzNetwork 2: 100 MHz - 400 MHzNetwork 3: 400 MHz - 1 GHz

Maximum Power 2 kWConnector Type N female

14

Antennas

HP 11966PBroadband AntennaThe HP 11966P broadbandantenna covers 30 MHz to 1 GHz.This broadband antenna removesthe need to change antennasabove 200 MHz when makingradiated EMI measurements.The antenna’s high powerhandling capability makes itideal for immunity testinggenerating fields of up to 10 volts/meter.

Frequency Range 30 MHz - 1 GHzMaximum Continuous Power 130 WVSWR (avg) 2 : 1Impedance (nominal) 50 ΩConnector Type N (female) Note: Tripod not included

Frequency Typical Antenna Factor(MHz) (dB)

30 18.250 8.070 5.090 8.0

100 9.5150 11.0200 10.0250 12.0300 13.0350 14.5400 16.2450 16.7500 18.5550 19.0600 19.8650 20.4700 21.1750 22.0800 23.0850 23.0900 23.0950 25.0

1000 25.0

1. All antennas sold by HP are individually calibrated. They include a calibrationcertificate showing actual performance data. The antenna factors shown in thiscatalog are intended to show typical performance only.

15

EMC Accessory Application Guide

Commercial Measurements

Agency Test Frequency Range Recommended Accessories

FCC Part 15conducted 450 kHz - 30 MHz HP 11967D or E LISN

radiated 30 MHz - 300 MHz HP 11966C Biconical Antenna200 MHz - 1 GHz HP 11966D Log Periodic Antenna

or28 MHz - 1 GHz HP 11966H Dipole Antenna Set1

HP 11966P Broadband Antenna200 MHz - 5 GHz HP 11966N Log Periodic Antenna

VDE 0871, 0875conducted 10 kHz - 30 MHz HP 11967D or E LISN

radiated 10 kHz - 30 MHz HP 11966A Active Loop30 MHz - 300 MHz HP 11966C Biconical Antenna200 MHz - 1 GHz HP 11966D Log Periodic Antenna

or28 MHz - 1 GHz HP 11966H Dipole Antenna Set 1

CISPR 14power 30 MHz - 300 MHz HP 11967A KO5 Absorbing Clamp

22conducted 150 kHz - 30 MHz HP 11967D or E LISN

radiated 28 MHz - 1 GHz HP 11966H Dipole Antenna Set1

VCCIconducted 150 kHz - 30 MHz HP 11967D or E LISN

radiated 30 MHz - 300 MHz HP 11966C Biconical Antenna200 MHz - 1 GHz HP 11966D Log Periodic Antenna

or28 MHz - 1 GHz HP 11966H Dipole Antenna Set1

CENELEC EN 55014conducted 150 kHz - 30 MHz HP 11967D or E LISN

radiated 30 MHz - 300 MHz HP 11966C Biconical AntennaEN 55022conducted 150 kHz - 30 MHz HP 11967D or E LISN

radiated 30 MHz - 1 GHz HP 11966C Biconical AntennaHP 11966D Log Periodic Antenna

EN 55011conducted 150 kHz - 30 MHz HP 11967D or E LISN

radiated 150 kHz - 1 GHz HP 11966A Active Loop AntennaHP 11966C Biconical AntennaHP 11966D Log Periodic Antenna

1. These adjustable dipole antennas are particularly suited for making accurate site attenuation measurements, such as thoseoutlined in the FCC’s OST-55 bulletin. They can also be used for making measurements of emissions from the equipment undertest (EUT). Broadband antennas, such as biconical and log periodic antennas, are typically used for emissions measurements ofthe EUT because of their ease of use.

16

Military Measurements

Agency Test Frequency Range Recommended Accessories

MIL-STD 461/462CE-01 30 Hz - 15 kHz HP 11967B Current Probe

0160-6683 10 µf Capacitor

CE-03 15 kHz - 50 MHz HP 11967A Current Probe0160-6683 10 µf Capacitor

CE-06 10 kHz - 12.4 GHz 11729-60014 Preamplifier

RE-01 30 Hz - 15 kHz HP 11966K Magnetic Coil

RE-02 14 kHz - 30 MHz HP 11966B Active Rod30 MHz - 300 MHz HP 11966C Biconical Antenna200 MHz - 1 GHz HP 11966D Log Periodic Antenna 2

orHP 11966F Conical Spiral Antenna

1 GHz - 10 GHz HP 11966E Waveguide Horn Antennaor

HP 11966G Conical Spiral AntennaHP 8449B Preamplifier 3

RE-03 10 kHz - 30 MHz HP 11966B Active Rod30 MHz - 300 MHz HP 11966C Biconical Antenna200 MHz - 1 GHz HP 11966D Log Periodic Antenna

orHP 11966F Conical Spiral Antenna

1 GHz - 10 GHz HP 11966G Conical Spiral Antenna1 GHz - 18 GHz HP 11966E Waveguide Horn Antenna1 GHz - 26.5 GHz HP 8449B Preamplifier 3

CE-101 30 Hz - 10 kHz HP 11967B Current Probe0160-668310 µf Capacitor

CE-102 10 kHz - 10 MHz HP 11967D or E LISN

RE-101 30 Hz - 50 kHz HP 11966K Magnetic Field Pickup Coil

RE-102 10 kHz - 30 MHz HP 11966B Active Rod30 MHz - 200 MHz HP 11966C Biconical Antenna200 MHz - 2 GHz HP 11966I Horn Antenna25 Hz - 18 GHz HP 11966E Double-ridged Horn Antenna

2. MIL-STD radiated emission 02 tests can be performed with either linearlypolarized antennas, such as the log periodic, or circularly polarized antennas, such asthe conical spiral. Linear antennas offer slightly better gain and antenna factor, butthey require separate scans over the full frequency range once in horizontal polarizationand again in vertical polarization. While circularly polarized antennas typically areslightly less sensitive, they allow the measurement to be made in a single scanbecause they can receive signals that have either horizontal or vertical polarization.

3. The HP 8449B microwave preamplifier offers improved sensitivity for microwaveemissions measurements. With improved sensitivity, wider receiver bandwidths canbe used, result in faster measurement times.

17

Antenna Masts

HP 11968B Manual AntennaPositioning Mast The 11968B is a lightweight,portable, antenna positioningmast. Antenna height is controlledwith a manual winch. The crossboom can be rotated 90 degreesto enable measurements inhorizontal and vertical polarization.This low-cost unit is ideal forprecompliance testing and isalso suitable for final qualificationmeasurements.

Mast Height 4.4 m (14.4 ft)Maximum Load at Tip of Cross-Boom 11.3 kg (25 Ib)

18

Equipment Testing Turntable

HP 11968EManual EquipmentTest TurntableThis manually operated, non-metallic turntable is suitable forboth indoor and outdoor use. It is especially useful in costsensitive applications, such asprecompliance testing.

Diameter 1.2 m (14 ft)Height 76 mm (3 in)Maximum Load 455 kg (1000 Ib)

19

HP 85876B CommercialRadiated EMI Measurement SoftwareThe HP 85876B commercialEMI measurement softwareruns in Microsoft® 3.1 or later,Windows 95 or Windows NT 4.0PC computing platform. Itcontains sophisticatedmeasurement algorithms andautomation capabilities that canhelp you increase your EMI testthroughput. A built-in reportgenerator enables you to portgraphics and data to popularword processing and spread-sheet programs. This software iscompatable with the HP 8542E,8522E, 8546A, 85462A, 8571A,8572A and other 8566B-basedsystems. The software alsosupports tower and turntablecontrollers Sunol Sciences CON 94revision 3.1, EMCO 1050, 1060and 2090 revision 2.0 or later,and Deisel HD100 revision 5.5.

HP 11968A K07Shielded Room KitThe HP 11968A K07 shieldedroom kit provides the cables andbulkhead connector to interfaceeither the HP 11968A antennamast or the HP 11968D turntableinside a shielded room to thecontrollers outside the room.

HP 11961AEMI Measurement SoftwarePerforms radiated andconducted emissionsmeasurements automatically.Measurements are corrected fortransducer losses and systemgains. Use the report generationcapabilities to documentmeasurement results.

HP 85878AEMI Report GeneratorLink the power of HP EMCanalyzers or EMI receivers toyour PC. Archive and viewdisplays, measurement lists,graphs and more. Generatereports automatically.

20

Cables l

HP 11966LThis 10 meter (32.8 ft) antennacable is constructed of RG-214/Ucoaxial cable with type-N maleconnectors at both ends.

HP 11966MThis 10 meter (32.8 ft) antennacable is constructed of RG-223/Ucoaxial cable with type-BNCmale connectors at both ends.

HP 11966A K47Five meter low-loss cable withAPC 3.5 male connectors.

HP 11966A K48Ten meter low-loss cable withAPC 3.5 male connectors.

HP 11500A CableSix foot long RG-214/U cablewith type-N connectors.

HP 11500F Cable150 centimeter cable with APC 3.5 male connector.

8120-1840122 centimeter (48 inches) coaxialcable with type-BNC maleconnectors at both ends.

Limiters

HP 11947ATransient LimiterIn precompliance applicationswhere a spectrum analyzer isused for measurements insteadof an EMI receiver, it is alwaysa good idea to use a transientlimiter. Transient limitersprotect the spectrum analyzerinput from damage caused byhigh-level transients from lineimpedance stabilizationnetworks (LISNs) during EMItesting for conducted emissions.

Frequency Range 9 kHz - 200 MHzInsertion Loss 10 dBMaximum Input Level Continuous: 2.5 W (+34 dBm)

Pulse: 10 kW for 10 µsecDC: ±12 V

1. Other custom cable lengths and types are available. For more information,consult your local HP sales representative.

21

Preamplifiers

HP 8447F Option H64Dual PreamplifierThis dual preamplifier improvesreceiver and spectrum analyzersensitivity. It is ideally suited foruse with the HP 11940A and11941A close-field probes todetect low-level emissions from a device under test. Radiatedemission measurements using aspectrum analyzer and antennaare improved by the increasedsensitivity that this unit offers.

Band 1 Band 2Frequency Range 9 kHz - 50 MHz 100 kHz - 1.3 GHzNoise Figure < 7.0 dB 8.5 dBGain 28 dB 26 dBGain Flatness ±2.0 dB ±1.5 dBConnector Type N female N female

11729-60014Low Noise PreamplifierThis amplifier provides thesensitivity needed for MIL-STD461C CE-06 receiver/transmitterkey-up testing.

Frequency Range 10 Hz - 25 MHzGain 40 dBPower Requirements +24 V DCConnector Type SMC female

HP 8449BMicrowave PreamplifierA high-gain, low-noise preampli-fier to provide additional sensiti-vity for MIL-STD radiatedmeasurements.

Frequency Range 1 GHz - 26.5 GHzNoise Figure 1.0 - 12.5 GHz 8.5 dB

12.5 - 22.0 GHz 12.5 dB22.0 - 26.5 GHz 14.5 dB

Minimum Gain 23.5 dBGain Flatness 1.0 - 26.5 GHz ± 4.5 dB

2.0 - 22.0 GHz ± 3.5 dBConnector Type APC - 3.5 female

22

Magnetic Field Probes

HP 11940A and 11941AClose Field ProbesThese hand-held probes arespecially designed to measuremagnetic field radiation fromsurface currents, slots, cables,and ICs for EMC diagnostic andtroubleshooting measurements.Their unique design results in ahigh level of electric field rejection.This significantly reduces errorsallowing calibrated and repeatablemeasurements. Each probe iscalibrated and comes with atwo-meter, RG-223 coaxial cable,an SMA(f) to Type-N(m) adapter,and an SMA(f) to BNC(m) adapter.

Frequency Range 11940A: 30 MHz - 1 GHz11941A: 9 kHz - 30 MHz

Maximum Input Power 0.5 WTemperature Range Variation over 0 °C to + 40 °CDielectric Breakdown ± 1 dB, typicalConnector SMA, replaceable barrelVSWR < 3 : 1, typical for 11940A onlyAntenna Factor Accuracy Individually calibrated to

within ± 2 dB in a 377 Ωfield impedance

HP 11945AClose Field Probe SetThe HP 11945A close field probeset includes both the 11940Aand 11941A probes to providefull coverage from 9 kHz to 1 GHz.This set provides a powerfulmeasurement tool for electricaland mechanical designers whowant to search for and eliminatesources of interference from theirproducts early in the designprocess. Option E51 adds theHP 8447F Option H64 dualpreamplifier, a 36 inch (914 mm)Type-N cable and a carrying bagto store and protect the entire setof probes, preamplifier, and cables.

23

Tripods

HP 11968C Antenna TripodThe HP 11968C is a non-metallictripod made of linen phenolicand delrin to minimize unwantedreflections in the test environment.

24

Misc. EMC Accessories

HP 85685A RF PreselectorThe HP 85685A RF preselectoris designed to operate with theHP 8566B and 8568B spectrumanalyzers. The RF preselectoradds tracking filters to reduceoverloading from out-of-bandsignal and preamplifiers forimproved system sensitivityover the 20 Hz to 2 GHz frequencyrange. The HP 85685A RFpreselector has two inputs, 20 Hz to 50 MHz and 20 MHz to2 GHz. There is also a bypass modewhich is DC to 18 GHz. Input 1has a built-in transient limiterfor protection from transientsgenerated by line impedencestabilization networks (LISN).

The RF preselector is fullyprogrammable over the HP-IB (IEEE-488).

Input SpecificationsInput 1 Input 2

Frequency Range 20 Hz - 50 MHz 20 MHz - 2 GHzBypass DC to 18 GHz

Connector Type BNC (50 Ω) Type-N (50 Ω)Fuse Blow Time < 0.1 sec for > + 35 dBm NA

Maximum Save Input PowerAverage + 30 dBm (1 W)Impulsive Signals 100 W peak for 10µ sec pulse

DC Voltage 0 V

Standing Wave Ratio> 10 dB RFP Atten < 1.5 : 1 < 1 .5 : 10 dB Atten < 1.5 : 1 nominal < 2.0 : 1 nominal

RFP Anen Range 0 - 50 dB (10 dB steps)Preamp Gain 20 dB for 0 dB RFP atten

OutputComb GeneratorLine Spacing 100 kHz, 500 kHz, 1 MHz, 5 MHz (nominal)Line Amplitude - 40 to - 60 dBm

Preselector Filters

Start Frequency Stop Frequency Filter Type(MHz) (MHz)

0.0 0.0655 Fixed tuned0.101 0.0756 Fixed tuned0.074 0.2051 Fixed tuned0.1975 0.5252 Fixed tuned0.525 1.0493 Fixed tuned1.025 2.0736 Fixed tuned1.96 5.8922 Variable5.83 17.3643 Variable17.33 28.8643 Variable28.73 51.7987 Variable51.73 97.8673 Variable97.83 152.356 Variable152.33 219.4389 Variable216.33 333.7705 Variable

HP 11960A EMC PreselectorReduces RF overload from broad-band and out-of-band signals.Perform near compliant conduc-tor emissions measurements.Improve radiated emissionmeasurement sensitivity. TheHP 11960A has a 30 dB gainamplifier built-in.

25

Misc. EMC Accessories

HP 85650A Quasi-PeakAdapterThe HP 85650A quasi-peakadapter is an accessory usedwith the HP 8566B or 8568Bspectrum analyzers for perform-ing quasi-peak measurementsas recommended by CISPR.These include the correct 6 dBband- widths (200 Hz, 9 kHz,120 kHz) and the specifieddetector charge and dischargetime constants.

The bypass mode returns thespectrum analyzer back tostandard operation unaffectedby the quasi-peak adapter. Inthe normal mode the threeCISPR bandwidths are avail-able and the quasi-peak detectorcan be turned on and off.

There is a built-in speaker andphone jack for monitoringsignals.

The HP 85650A provides nineform C (SPDT) auxilliary switchescan be used with external powersupplies to switch coax relays,DUT power, or your individualswitching needs. Six switchesare multiplexed such that whenone is on five are off.

All functions are controlled overthe HP-IB (IEEE 488) exceptvolume and line.

Frequency Bandwidth Charge DischargeBand (MHz) at 6 dB TC (ms) TC (ms)0.01 - 0.15 200 Hz 45 5000.15 - 30 9 kHz 1 16030 - 1000 120 kHz 1 550

Quasi-peak Response to CISPR Pulse (dBµV)

PRF (Hz) 10 to 150 kHz 0.15 to 30 MHz 30 to 1000 MHz1000 --- 64.5 ± 2.5 68.0 ± 2.5100 64.0 ± 2.5 60.0 ± 1.5 60.0 ± 1.560 63.0 ± 2.5 --- ---25 60.0 ± 1.5 --- ---20 --- 53.5 ± 2.5 51.0 ± 2.510 56.~± 2.5 50.0 ± 3.0 46.0 ± 3.05 52.5 ± 3.0 --- ---2 47.0 ± 3.5 39.5 ± 3.5 34.0 ± 3.51 43.0 ± 3.5 37.5 ± 3.5 31.5 ± 3.5IsolatedPulse 41.0 ± 3.5 36.5 ± 3.5 28.5 ± 35

Ordering Information

Listed by Hewlett-Packard Model Number

Model Number

HP 11500AHP 11500FHP 11940AHP 11941AHP 11945AHP 11947AHP 11955AHP 11956AHP 11960AHP 11961AHP 11966AHP 11966A K12HP 11966A K24HP 11966A K30HP 11966A K38HP 11966A K40HP 11966A K47HP 11966A K48HP 11966BHP 11966CHP 11966DHP 11966EHP 11966FHP 11966GHP 11966HHP 11966IHP 11966JHP 11966KHP 11966LHP 11966MHP 11966NHP 11966PHP 11967A K05HP 11967A K06HP 11967A K23HP 11967AHP 11967BHP 11967DHP 11967EHP 11968A K07HP 11968BHP 11968CHP 11968EHP 8447F H64HP 8449BHP 85650AHP 85685AHP 85876AHP 85878A0160-66838120-184011729-60014

Description

Six foot RG-214U Cable with Type-N Connector150 cm Cable (APC 3.5 Male Connectors)Close Field Probe 30 MHz to 1 GHzClose Field Probe 9 KHz to 30 MHzClose Field Probe SetTransient LimiterBiconical AntennaLog Periodic AntennaEMC PreselectorEMI Measurement SoftwareActive Magnetic Loop AntennaPassive Loop SetBiconical Antenna 20 MHz to 300 MHz (2000 Watts)Passive Rod AntennaBiconical Antenna 30 MHz to 300 MHz (300 Watts)Royce Field Site SourceFive Meter Cable (APC 3.5 Male Connector)Ten Meter Cable (APC 3.5 Male Connector)Active Monopole AntennaBiconical Antenna 30 MHz to 300 MHzLog-Periodic Antenna 200 MHz to 1 GHzDouble-Ridged Waveguide Horn Antenna 1 to 18 GHzConical Log Spiral Antenna 200 MHz to 1 GHzConical Log Spiral Antenna 1 GHz to 10 GHzDipole Antenna Set 28 MHz to 1000 MHzHorn Antenna 200 MHz to 2 GHzHorn Antenna 18 GHz to 40 GHzMagnetic Field Pickup Coil 20 Hz to 50 kHzCoaxial Cable 10 Meter Type-NCoaxial Cable 10 Meter BNCLog Periodic Antenna 200 MHz to 5 GHzBroadband AntennaAbsorbing ClampCavity Rejection NetworkBridged-T Rejection NetworksCurrent Probe 15 kHz to 50 MHzCurrent Probe 20 Hz to 2 MHz10 Amp Line Impedance Stabilization Network25 Amp Line Impedance Stabilization NetworkShielded Room KitManual Antenna Positioning MastAntenna TripodManual Equipment Test TurntableDual Preamplifier 0.1 to 1300 MHzMicrowave Preamplifier 1 GHz to 26.5 GHzQuasi-Peak AdapterRF PreselectorCommercial Radiated EMI SoftwareEMI Report Generator10 µF Capacitor122 Centimeter Coaxial CableLow Noise Preamplifier

For more information aboutHewlett-Packard test and measure-ment products, applications andservices, and for a current salesoffice listing, visit our Web site,http://www.hp.com/go/tmdir. Youcan also contact one of the followingcenters and ask for a test andmeasurement sales representative.

United States:Hewlett-Packard CompanyTest and Measurement Call CenterP.O. Box 4026Englewood, CO 80155-40261 800 452 4844

Canada:Hewlett-Packard Canada Ltd.5150 Spectrum WayMississauga, Ontario L4W 5G1(905) 206 4725

Europe:Hewlett-PackardEuropean Marketing CentreP.O. Box 9991180 AZ AmstelveenThe Netherlands(31 20) 547 9900

Japan:Hewlett-Packard Japan Ltd.Measurement Assistance Center9-1, Takakura-Cho, Hachioji-Shi,Tokyo 192, JapanTel: (81) 426-56-7832Fax: (81) 426-56-7840

Latin America:Hewlett-PackardLatin American Region Headquarters5200 Blue Lagoon Drive, 9th FloorMiami, Florida 33126, U.S.A.(305) 267 4245/4220

Australia/New Zealand:Hewlett-Packard Australia Ltd.31-41 Joseph StreetBlackburn, Victoria 3130, Australia1 800 629 485

Asia Pacific: Hewlett-Packard Asia Pacific Ltd.17-21/F Shell Tower, Times Square,1 Matheson Street, Causeway Bay,Hong KongTel: (852) 2599 7777Fax: (852) 2506 9285

Prices and Data Subject to ChangeCopyright © 1997Hewlett-Packard CompanyPrinted in U.S.A. 9/975966-1188E


Recommended