EMC Calibration SErviCESReliable – fast – woRldwide
Advanced Test Equipment Rentalswww.atecorp.com 800-404-ATEC (2832)
®
Established 1981
GLOBAL6 accredited calibration and repair centers.
NATIONALAccredited and traceable calibrations.National and international standards.
ON-SITEOn-site calibration.Fast turnaround for send-in service.
KNOW-HOWMembership in standards committees.Calibration of any EMC manufacturer’s equipment.
GLOBAL6 accredited calibration and repair centers.
NATIONALAccredited and traceable calibrations.National and international standards.
ON-SITEOn-site calibration.Fast turnaround for send-in service.
KNOW-HOWMembership in standards committees.Calibration of any EMC manufacturer’s equipment.
3
SErviCE YoU Can trUSt
Get your calibration services from the eMC experts who also develop and manufacture eMC test instruments.
Teseq® provides calibration and repair services for a wide range of EMC test equipment from all manufacturers, including the complete Teseq product line. Our worldwide certified calibration centers provide a wide range of value-added services, including upgrades, system tuning and modifications to meet the latest standards. We also provide on-site cali-bration and repair services.
In support of our commitment to world-class customer service, Teseq®
guarantees 7 years of post phase-out support on all our products, includ-ing test instruments sold under the Schaffner label.
REPAIR, ADJUSTMENT AND CALIBRATION
CALIBRATION ONLY
REPAIR, ADJUSTMENT AND CALIBRATION
REPAIR
4
tESEq® SErviCE toUChpointS Reduce dOWn-time fOR test equipment
on-site calibration: the fastest way for critical instruments
Reduce down-time for critical test equipment and avoid costly shipping charges for large systems by taking advantage of our on-site calibration service. in addition to normal Rf and power line EMC instrumentation, Teseq® also performs on-site calibration for anechoic test chambers and open area test sites (OATS).
ship to teseq service lab: fast, reliable, high-quality service
Teseq® has 6 worldwide accredited calibration and repair labs with industry leading turnaround times. We provide timely, cost-effective modi-fications and upgrades to accommodate new standards, as well as free firmware updates for increased performance to protect your invest-ment.
ship to independent calibration laboratory: longer down-time and limited service
3rd party calibration labs do not offer upgrade, adjustment or repair services that may be needed to complete the calibration service. This means additional time and cost to ship the equipment back to the manufacturer for service, and to perform a second calibration.
5
Calibration SErviCE
on-site calibration reduces down-time for test equipment. The incon-venience and cost of shipping large devices can be avoided by taking advantage of Teseq®’s on-site calibration service. in addition to normal Rf and power line EMC instrumentation, Teseq® routinely performs on-site calibration for anechoic test chambers and open area test sites (OATS).
Teseq® provides worldwide on-site calibration for
Anechoic test chambers
Open area test sites (OATS)
Shielding effectiveness
Site surveys
power line emc instrumentation
Rf instrumentation
Harmonics & flicker
Transients
Additional Teseq® calibration service benefits:
Detailed calibration (more measuring points)
exhaustive certification process
Concurrent repairs and upgrades as needed
free firmware/updates for many products
EMC calibration service for all manufacturers’ equipment
6
a2la
USA
American Association
for Laboratory
Accreditation
2273.01
www.a2la.org
a2la
Singapore
American Association
for Laboratory
Accreditation
2939.01
www.a2la.org
a2la
Japan
American Association
for Laboratory
Accreditation
2127.03
www.a2la.org
dakks
Germany
DAkkS Deutsche
Akkreditierungsstelle
D-K-15033-01-00
www.dakks.de
sCs
Switzerland
Swiss Calibration
Service
SCS 056
www.seco.admin.ch/sas
UKas
United Kingdom
Accreditation Service
0445/0392
www.ukas.com
teseq® accredited Calibration = Global Competence
Teseq®’s accredited calibration service is primarily suited to the needs of commercial test laboratories and manufacturers with accredited calibration requirements.
Accreditation is conferred on test laboratories by numerous agencies worldwide. Teseq® laborato-ries have obtained accreditation from DAkkS (Germany), SAS (Switzerland), UKAS (United Kingdom) and A2LA (USA, Singapore and Japan). Since the International Laboratory Accreditation Coopera-tion (ILAC) has developed a Mutual Recognition Agreement (MRA) for international cooperation between agencies to promote the acceptance of accredited test and calibration results around the globe, Teseq® can provide accredited calibrations for test equipment on worldwide basis.
Teseq®’s test laboratories are accredited in accordance with en isO/iec 17025, which requires technical personnel with specific skills and experience, merged with a technically sophisticated and modern infrastructure, in a quality-driven organization.
aCCrEDitED Calibration
7
traCEablE Calibration
teseq® Traceable Calibration = Customer Confidence
Teseq®’s traceable calibration service is ideal for all types of commercial and in-house test laboratories. Our traceable calibration procedure is based on the same calibration equipment, procedures, measurement uncertainties and personnel which have been assessed by national accreditation authorities to ensure measurement accuracy and quality. This means that Teseq® customers receive accurate, cost-effective service in situations where accreditation is not required.
Our traceable calibration procedures follow the requirements of en isO/iec 17025 and isO 9000, making our service superior to the typical calibration services of other laboratories.
8
Calibration anD rEpair CapabilitiES
Teseq®’s extensive calibration and repair capability encompasses all common and specialized EMC test equipment from any manufacturer, from simple instruments and accessories to the most sophisticated test sites.
Product Specification Range Standards
esd simulators esd 30 kV / 140 A iec 61000-4-2, isO 10605
Pulse generators fast transients 8 kV iec 61000-4-4 combination wave surge 10 kV / 5 kA iec 61000-4-5, Ansi c62.41 Ring wave surge 10 kV / 5 kA iec 61000-4-12, Ansi c62.41 telecom surge 10 kV / 5 kA ccitt, itu, fcc to manufacturers’ specs mains drop-out 700 V / 500 A iec 61000-4-11, iec 61000-4-29, IEC 61000-4-34
automotive pulse fast transients 1500 V isO 7637, sAe, JAsO, generators Company standards Microsecond pulses 1000 V Load dumps 1000 V Battery power quality 100 V / 300 A / 10 mHz
Harmonics and flicker Mains harmonics and IEC 61000-4-7, IEC 61000-3-2, flicker emission iec 61000-3-3, iec 61000-3-11, measurement, mains IEC 61000-3-12 power variation immunity tests
Receivers and analyzers measuring receivers cispR 16-1-1 click analyzers cispR 16-1-1, cispR 14-1
Sinus wave generators, 10 kHz to 400 MHz ISO 11452, MIL 461, immunity test systems power meters, 150 kHz to 230 MHz IEC 61000-4-3, directional couplers 80 MHz to 1 (6) GHz IEC 61000-4-6
9
Product Specification Range Standards
Power amplifier Low, medium, up to 1 kW high Rf power up to 6 GHz
antennas BiLog/X-wing (compact) 20 mHz to 3 GHz BiLog Biconical 20 MHz to 1 GHz dipole 30 to 100 mHz en 50147-2, Ansi c63.4, en 55022, cispR 16-1-4 (cispR 16-1-6), Vcci:V-3 Loops (active & passive) 9 kHz to 30 MHz a reference loop antenna Broadband horns up to 18 GHz Rod 9 kHz to 30 MHz
Probes and clamps current sensing/injection 10 kHz to 400 mHz miL 461, cispR 16-1-2 capacitive voltage 150 kHz to 30 mHz cispR 16-1-2 near field probes 9 kHz to 1 GHz manufacturers’ specs Absorbing clamps 30 mHz to 1 GHz cispR 16-1-3, cispR 16-1-4 EM clamps 10 kHz to 1 GHz IEC 61000-4-6
Networks coupling/decoupling 10 kHz to 300 mHz iec 61000-4-6, cispR 15 networks (cdn) impedance stabilization 150 kHz to 30 mHz cispR 22, cispR 16-1-2 networks (isn) Line impedance 9 kHz to 30 mHz cispR 16-1-2 stabilization networks (Lisn)
teM cells GTEM cells IEC 61000-4-20, DTEM cells to manufacturers’ specs Strip line
Chamber calibration normalized site 30 to 1000 mHz Ansi c63.4, en 50147-2 services attenuation (nsA) OAts 30 to 1000 mHz Ansi c63.4, cispR 16 field uniformity iec 61000-4-3 + Amd 1, en 61000-4-3 + Amd 1, Bs en 61000-4-3 Shielding effectiveness Electromagnetic site surveys Reverberation chambers chamber calibration sVsWR 1 to 18 GHz cispR 16-1-4
10
SCopE of Calibration
esd pulses, e.g. ieC 61000-4-2/iso 10605 to 30 kV
burst pulses, e.g. ieC 61000-4-4 to 8 kV
surge pulses, e.g. ieC 61000-4-5 to 10 kV
Power magnetic field, e.g. IEC 61000-4-8
Mains drop-outs and dips, e.g. ieC 61000-4-11
Ring wave pulses, e.g. ieC 61000-4-12
Conducted coupling and decoupling networks
Mains drop-outs and dips, dC ieC 61000-4-29
automotive pulse generators
RF Power amplifiers
Electric field strength 10 kHz to 8 GHz
field strength probes dC to 18 GHz
eMi measuring receivers
teM wave guides (e.g. GteM cells) ieC 61000-4-20
Chambers
Rf Coupling and decoupling networks (lisNs, isNs, CdNs, clamps)
Current clamps
directional couplers
RF probes, RF pre-amplifiers and attenuators
Rf power meters
Rf generators
antennas
lVd testers
Harmonics and flicker
on-site conducted eMC calibration
trac
eab
le
a2l
a a
ccre
dit
atio
n
eN is
o/i
eC 1
7025
a2l
a a
ccre
dit
atio
n
eN is
o/i
eC 1
7025
a2l
a a
ccre
dit
atio
n
eN is
o/i
eC 1
7025
UK
as
acc
red
itat
ion
eN
iso
/ieC
170
25
dK
d a
ccre
dit
atio
n
eN is
o/i
eC 1
7025
sa
s a
ccre
dit
atio
n
eN is
o/i
eC 1
7025
trac
eab
le
trac
eab
le
trac
eab
le
trac
eab
le
trac
eab
le
trac
eab
le
Teseq AG Switzerland
Teseq GmbH Germany
Teseq Ltd. UK
Teseq Inc. USA
Teseq pte Ltd. Singapore
Teseq K.K. Japan
Teseq Com- pany Limited China
11
SWITZERLANDJAPAN
Teseq AGNordstrasse 11F4542 [email protected] +41 32 681 40 40
Teseq K.K. Nagoya Office1-329 Kifune Meito-Ku465-0058 [email protected] +81 52 709 5501
tESEq®’S CUStoMEr SUpport tEaMS
our enthusiastic customer support teams are there for you around the clock, dedicated to get your requests done on time, anywhere, anytime!
12
USA SINGAPORE GERMANY UKTeseq Pte Ltd.Blk 3015A Ubi Road 105-09 Kampong Ubi Industrial EstateSingapore 408 [email protected] +65 6846 2488
Teseq Inc.52 Mayfield AvenueEdison, New Jersey [email protected] +1 888 417 0501
Teseq GmbHLandsberger Strasse 25512623 [email protected] +49 30 56 59 8835
Teseq Ltd.5 Ashville WayMolly Millars LaneWokingham, Berkshire RG41 [email protected] +44 845 074 0660
CUStoMEr SUpport tEaMS
13
USA SINGAPORE GERMANY UKTeseq Pte Ltd.Blk 3015A Ubi Road 105-09 Kampong Ubi Industrial EstateSingapore 408 [email protected] +65 6846 2488
Teseq Inc.52 Mayfield AvenueEdison, New Jersey [email protected] +1 888 417 0501
Teseq GmbHLandsberger Strasse 25512623 [email protected] +49 30 56 59 8835
Teseq Ltd.5 Ashville WayMolly Millars LaneWokingham, Berkshire RG41 [email protected] +44 845 074 0660
the teseq Human touch is probably the most valuable favor we can do for our clients. We care personally for your work and we stand fully engaged to support your needs and wants. Whenever, wherever.
14
CHINA TAIWANTeseq (Taiwan) Ltd.3F.-2, No. 92, Baozhong RdXindian Dist.New Taipei City [email protected] +886 2 2917 8080
Teseq Company LimitedRoom 1001 - Sky PlazaNo. 46 Dongzhimenwai Dajie100027 [email protected] +86 10 8460 8080
a fUll ranGE of EMC SErviCES
With more than 40 years of experience, teseq® has the resources to address any type of EMC challenge. Our extensive range of services and skills can be tailored to meet your specific needs.
Consultation and training. Our experts can provide support to a new lab, to expand it for additional tests or to strengthen your staff’s knowledge.
EMC consultation
Training courses and seminars
EMC training is available on request in our labs or on-site.
software and automation. Teseq®’s Compliance 5 lab automation software can easily be customized to your processes for higher efficiency and throughput in your lab.
Test methodology advice
Test automation software development
fast and easy customization
Maintenance contracts
system integration. We design and build turn-key emc systems to precisely fit your test requirements, budget and time frame.
emc system specification
EMC system design and implementation services
EMC system installation and training
EMC system upgrades
Headquartersteseq aG4542 Luterbach Switzerlandt +41 32 681 40 40f +41 32 681 40 [email protected]
EMC inStrUMEntation anD SYStEMS to SUit anY bUDGEt
Chinateseq Company limitedt +86 10 8460 8080f +86 10 8460 [email protected]
singaporeteseq Pte ltd.t +65 6846 2488f +65 6841 [email protected]
Usateseq inc.t +1 732 417 0501f +1 732 417 0511toll free +1 888 417 [email protected]
franceteseq sarlt +33 1 39 47 42 21f +33 1 39 47 40 [email protected]
switzerlandteseq aGt +41 32 681 40 50f +41 32 681 40 [email protected]
Germanyteseq GmbHt +49 30 5659 8815f +49 30 5659 [email protected]
taiwanteseq (taiwan) ltd.t +886 2 2917 8080f +886 2 2917 [email protected]
Japanteseq K.K.t +81 3 5725 9460f +81 3 5725 [email protected]
UKteseq ltd.t +44 845 074 0660f +44 845 074 [email protected]
teseq® offers the world’s most comprehensive range of eMC systems for immunity and emissions testing. We take great pride in our world-class research and development program, backed by state-of-the-art global manufacturing. Our membership in the relevant international committees demonstrates our commitment to the industry. Our network of agents and distributors offers market leading EMC expertise tailored to local needs in more than 30 different countries.
Our unique ‘modular’ approach to EMC is focused on our customers’ business needs. By breaking down the barriers between traditionally separate test functions we can optimize the test process to help you bring products to market more quickly.
to find your local partner within
Teseq®’s global network, please go to www.teseq.com
691-022C May 2012
© 2012 Teseq® specifications subject to change without notice.
Teseq® is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001.
This document has been carefully checked. However, Teseq® does not assume any liability for errors or inaccuries.