SHENZHEN LCS CERTIFICATION SERVICES INC.REPORT NO. LCS080830831E
EMC TEST REPORT
For
Car Charger
Model No.:SO-2210
Address : SHISHUIKOU MANAGEMENT ZONE,QIAO TOU
TOWN,DONGGUAN,GUANGDONG,CHINA
Prepared By : SHENZHEN LCS CERTIFICATION SERVICES INC.
Address :12/F.,Tower A,Pengdou Building,Nanhai Road,
Nanshan District,Shenzhen,Guangdong, China
Tel:86-769-82760771
Fax:86-769-82769339
Report Number :LCS080830831E
Date of Test :September 01,2008
Date of Report :September 02,2008
Page 1 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC.Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Soo Electronics Co., Ltd.
Prepared for SOO ELECTRONICS CO., LTD
Tel 86-769-85637787
Fax 86-769-85637780
TABLE OF CONTENT
Description Page TEST REPORT DESCRIPTION
1.GENERAL INFORMATION 5
1.1 Description of Device(EUT) 5
1.2Description of Test Facility 6
1.3Measurement Uncertainty 6
2.MEASURING DEVICE AND TEST EQUIPMENT 7
2.1For Radiated Emission Measurement 7
2.2For Electrostatic Discharge Immunity Test 7
2.3For RF Strength Susceptibility Test 7
2.4For Electrical Fast Transient/ Burst Immunity Test 7
2.5For Surge Immunity Test 8
2.7For Injected Current Susceptibility Test 8
2.8For Magnetic Field Immunity Test 8
3.RADLATED EMISSION MEASUREMENT 9
3.1Block Diagram of Test 9
3.2MeasuringStandard 9
3.3Radiated Emission Limits 10
3.4EUT Configuration on Test 10
3.5Operating Condition of EUT 10
3.6TestProcedure 10
3.7Measuring Results 10
4.ELECTROSTATIC DISCHARGE IMMUNITY TEST 11
4.1BlockDiagramof Test Setup 11
4.2Test Standard 11
4.3Severity Levels and Performance Criterion 11
4.4EUT Configuration 12
4.5Operating Condition of EUT 12
4.6Test procedure 12
4.7Test Results 12
5.RF FIELD STRENGTH SUSCEPTIBILITY TEST 14
5.1Block Diagram of Test 14
5.2Test Standard 14
5.3Severity Levels and Performance Criterion 15
5.4EUT Configuration on Test 15
5.5Operating Condition of EUT 15
5.6Test procedure 15
5.7Test Results 15
6.ELECTRICAL FAST TRANSIENT/BURST LMMUNITY TEST 17
Page 2 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC . Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
6.1Block Diagram of Test Setup 17
6.2Test Standard 17
6.3Severity Levels and Performance Criterion 17
6.4EUT Configuration 18
6.5Operating Condition of EUT 18
6.6Test Result 18
7.SURGE IMMUNITY TEST 20
7.1Block Diagram of Test Setup 20
7.2Test Standard 20
7.3Severity Levels and performance Criterion 20
7.4EUT Configuration 21
7.5Operating Condition of EUT 21
7.6Test Procedure 21
7.7Test Result 21
8.INJECTED CURRENTS SUSCEPTIBILITY TEST 23
8.1Block Diagram of Test Setup 23
8.2Test Standard 23
8.3Severity Levels and Performance Criterion 23
8.4EUT Configuration 24
8.5Operating Condition of EUT 24
8.6Test Procedure 24
8.7Test Results 24
9.MAGNETIC FIELD SUSCEPTIBILITY TEST 26
9.1Block Diagram of Test 26
9.2Test Standard 26
9.3Severity Levels and Performance Criterion 26
9.4EUT Configuration on Test 27
9.5Test Procedure 27
9.6Test Results 27
10.PHOTOGRAPH 29
APPENDLX I(2 Pag es)
APPENDLX II(Photos of EUT 2 Pages )
Page 3 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC .Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONICS CO., LTD
TEST REPORT DESCRIPTION
ETU :Car Charger
Model No. :SO-2210
Input Voltage :5.2V±0.2V,1A
Measurement Procedure Used :
EN55022:2006
EN55024:1998+A1:2001+A2:2003
(EN61000-4-2:1995+A1:1998+A2:2001,EN61000-4-3:2006,EN61000-4-4:2004,
EN61000-4-5:2006,EN61000-4-6:1996+A1:2001,En61000-4-8:1993+A1:2001)
The device describes above is tested by SHENZHEN LCS CERTIFICATION SERVICES
INC.to determine the maximum emission levels emanating from the device and the severe
levels of the device can endure and its performance criterion. The measurement results are
contained in this test report and SHENZHEN LCS CERTIFICATION SERVICES INC. is
assumed full of responsibility for the accuracy and completeness of these measurements.Also,
this repor shows that the EUT (Equipment Under Test )is technically compliant with the
EN55022 and EN55024 requirements.
This report applies to above tested sample only and shall not be reproduced in part without
written approval of SHENHEN LCS CERTIFICATION SERVICES INC .
Date of Test: September 01,2008
Prepared by:
(Engineer)
Reviewed by:
(Quality Manager)
Page 4 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Manufacturer SOO ELECTRONICS CO., LTD
1.GENERAL INFORMATION
1.1Description of Device(EUT)
EUT :Car Charger
Model Number :SO-2210
Power Supply :5.2V±0.2V,1A
Address :SHISHUIKOU MANAGEMENT ZONE, QLAO TOU TOWN,
DONGGUAN,GUANGDONG,GHINA
DONGGUAN,GUANGDONG,CHING
Date of sample :August 30, 2008
Received
Date of Test : September 01,2008
Page 5 of 34
SHENZHEN LCS CERTIFICATION SERVICES LNC. Report No,LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONLCS CO., LTD
Manufacturer SOO ELECTRONICS CO., LTD
1.2Description of Test Facility Site Description
EMC Lab. :Accredited by TUV Rheinland,July,2007
The Certificate Registration No. is 1700448 002.
Accredited by FCC, July07,2005
The Certificate Registration Number. is 662850.
Accredited by Industry Canada, Nov.28,2005
The Certificate Registration Number. is 46405-5377
1.3Measurement Uncertainty
Radiation Uncertainty :Ur=±4.26dB
Conduction Uncertainty :Uc=±2.66dB
Page 6 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
2.MEASURING DEVICE AND TEST EQUIPMENT
2.1For Radiated Emission Measurement
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal.
Interval
1. Spectrum Analyzer ANRITSU MS2661C 6200140915 May29,2008 1 Year
2. Test Receiver Rohde Schwarz ESCS30 82895/018 May29,2008 1Year
3. Bilong Aatenna Schwarzbeck VULB9163 142 May29,2008 1Year
4. 50 Coaxial Switch Anritsu Corp MP59B 6100237248 May 29,2008 1 Year
5. Cable Schwarzbeck AK9513(lm) CR RX 2 May 29,2008 1Year
6. Cable Schwarzbeck AK9513(10m) AC RX1 May29,2008 1 Year
7. Cable Rosenberger N/A(6m) CR RX1 May29,2008 1 Year
8. Cable Rosenberger N/A(10m) FP2RX2 May29,2008 1 Year
9. DC Power Filter MPE 23872C N/A May29,2008 1 Year
10. Single Phase Power
line Filer
MPE 23332C N/A May29,2008 1 Year
11. 3Phase Power Line
Filter
MPE 23333C N/A May29,2008 1 Year
12 Signal Generator HP 8648 3625U00573 May29,2008 1 Year
2.2For Electrostatic Discharge immunity Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. ESD Tester HAEFELY PESD1600 H708159 May 29,2008 1 Year
2.3For RF Strength Susceptibility Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal.Interval
1. Signal Generator HP 8648A 3625U00573 May29,2008 1 Year
2. Amplifier AR 500A100 17034 NCR NCR
3. Amplifier AR 100W/1000M1 17028 NCR NCR
4. Isotropic Field Monitor AR Fm2000 16829 NCR NCR
5. Isotropic Field Probe AR FP2000 16755 May29,2008 1 Year
6. Bionic Antenna EMCO 3108 9507-2534 NCR NCR
7. Log-periodic
Antenna
AR AT1080 16812 NCR NCR
8. PC N/A 486DX2 N/A N/A N/A
2.4For Eletrical Fast Transient/Burst Immunity Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. Burst Tester HAEFELY PEFT4010 080981-16 May29,2008 1 Year
2. Coupling Clamp HAEFELY IP-4a 147147 May29,2008 1 Year
Page 7 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
2.5For Surge Immunity Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. Surge Tester HAEFELY PSURGE4.1 080107-04 May29,2008 1 Year
2.7For Injected Current Susceptibility Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. Simulator EMTEST CWS500C 0900-12 May29,2008 1 Year
2. CDN EMTEST CDN-M2 5100100100 May29,2008 1 Year
3. CDN EMTEST CDN-M3 0900-11 May29,2008 1 Year
4. Injection
Clamp
EMTEST F-2031-23
MM
368 May29,2008 1 Year
5. Attenuator EMTEST ATT6 0010222A May29,2008 1 Year
2.8For Mannetic Field Immunity Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. Magnetic Field Tester HAEFELY MAG100 250040.1 May29,2008 1 Year
Page 8 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
3.RADIATED EMISSION MEASUREMENT
3.1Block Diagram of Test
3.1.1. Block diagram of connection between the EUT and simulators.
5.2V ←
(EUT:Car Charger)
3.1.2.Block diagram of test setup(In chamber)
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
3METERS
EUT and Simulators System
0.8METER
GROUND PLANE
(EUT:Car Charger)
3.2Measuring Standard
EN55022:2006
Page 9 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS 080830831E
EUT Load
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
3.3Radiated Emission Limits
All emanations from a class B device or system,including any network of conductors
and apparatus connected thereto,shall not exceed the level of field strengths specified
below:
FREQUENCY
(MHz)
DISTANCE
(Meters)
FIELD STRENGTHS
LIMIT(dBuV/m)
30~230 10 30
230~1000 10 37
Note:(1)The smaller limit shall apply at the combination point between two
frequency bands.
(2)Distance refers to the distance in meters between the measuring
instrument antenna and the closed point of any part of the EUT.
3.4EUT Configuration on Test The configuration of EUT are listes in Section3.4.
3.5Operating Condition of EUT
3.5.1.Turn on the power.
3.5.2.After that,let the EUT work in test mode (ON)and measure it.
3.6 Test Procedure
The EUT is placed on a turn table which is 0.8 meter high above the ground. The turn
table can rotate.360 degrees ot determine the position of the maximum emission level.
The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna
tower.The antenna can be moved up and down from 1 to 4 meters to find out the
maximum emission level.Bilong antenna(calibratedby Dipole Antenna)is used as a
receiving antenna .Both horizontal and vertical polarization of the antenna are set on test.
The bandwidth of the Receiver(ESCS30)is set at 120kHz.
All the scanning curves are attached in Appendix I.
3.7Measuring Results
PASS.
The frequency range from 30MHz to 1000MHz is investigated.
Page 10 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC .Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
4.ELECTROSTATIC DISCHARGE IMMUNITY TEST
4.1Block Diagram of Test Setup
4.1.1.Block diagram of connection between the EUT and Load
5.2V
(EUT:Car Charger)
4.1.2.Block diagram of ESD test setup
■
0.8m AC Mains AC Mains
(EUT:Car Charger)
4.2Test Standard
EN55024:1998+A1:2002+A22003(EN61000-4-2:1995+A1:1998+A2:2001
Severity Level:3/Air Discharge:±8KV level:2/Contact Discharge: ±4KV)
4.3Severity Levels and performance Criterion
4.3.1 Severity level
Level Test Voltage
Contact Discharge(KV)
Test Voltage
Air Discharge(KV)
1. ±2 ±2
2. ±4 ±4
3. ±6 ±8
4. ±8 ±15
X Special Special
4.3.2Performance criterion : B
Page 11 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC . Report No.LCS080830831E
EUT Load
EUT
ESD
Tester
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
4.4EUT Configuration The configuration of EUT are listed in Section 3.4.
4.5Operating Condition of EUT
4.5.1 Setup the EUT as shown on Section 4.1.
4.5.2Turn on the power of all equipments.
4.5.3Let the EUT work in measuring mode(ON)and measure it.
4.6Test Procedure
4.6.1 Air Discharge:
This test is done on a non-conductive surface.The round discharge tip of the discharge
electrode shall be approached as fast an possible to touch the EUT.After each discharge,
the discharge electrode shall be removed from the EUT.
the generator is then re-triggered for a new single discharge and repeated 100
times for each pre-selected test point. This procedure shall be repeated until all
the air discharge completed
4.62 Contact Discharge:
All the procedure shall be same as Section 4.6.1.except that the tip of the
discharge electrode shall touch the EUT before the discharge switch is operated.
4.63Indirect discharge for horizontal coupling plane:
AT least 50single discharges shall be applied to the horizontal coupling plane,at points
on each side of the EUT. The discharge electrode plsitions vertically at a distance of
0.1m from the EUT and with the discharge electrode touching the coupling plane.
4.64 Indirect discharge for vertical coupling plane:
At least 50 single discharge shall be applied to the center of one vertical edge of the
coupling plane.The coupling plane, of dimensions 0.5mX 0.5m, is placed parallel to,
and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the
coupling plane, with this plane in sufficient different positions that the four faces of the
EUT are completely illuminated.
4.7 Test Results
PASS
Please refer to the following pages
Page 12 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC.Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Electrostatic Discharge Test Results
SHENZHEN LCS CERTIFICATION SERVICES INC.
EUT :Car Charger Test Date : September 01 ,2008
M/A : SQ-2210 Temperature : 22℃
Power Supply : 5.2V Humidity : 55%
Air discharge : ±8.0KV Test Mode : ON
Contact diacharge :±4.0KV Criterion : B
Location Kind
A-Air Discharge C-Contact
Discharge
Result
DC output port 2points A PASS
Others slot of EUT 5points A PASS
HCP C PASS
VCP of front C PASS
VCP of rear C PASS
VCP of left C PASS
VCP of right C PASS
Test Equipment: ESD Simulator(HAEFELY,PESD1600)
Page 13 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No,LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONICS CO., LTD
5.RF FIELD STRENGTH SUSCEPTIBILITY TEST
5.1Block Diagram of Test
5.1.1Block diagram of connection between the EUT and Load.
5.2V
(EUT:Car Charger)
5.1.2Block diagram of RS test setup.
3Meters
EUT
Anechoic
Chamber 0.8
Meter
Measurement
Room
(EUT:Car Charger)
5.2Test Standard EN55024:1998+A1:2001+A2:2003
(EN61000-4-3;2006,Severity Level:2,3V/m)
Page 14 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No.LCS080830831E
EUT Load
Power Amp Signal
Generator
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
5.3Severity Levels and Performance Criterion 5.3.1Severity Levels
Level Field Strength V/m
1. 1
2. 3
3. 10
X Special
5.3.2Performance Criterion:A
5.4EUT Configuration on Test The configuration of the EUT is same as Section 3.4.
5.5Operating Condition of EUT
5.5.1 Setup the EUT as shown on Section5.1.
5.5.2 Turn on the power of all equipments.
5.5.3 Tet the EUT work in measuring mode(ON)and measure it..
5.6Test Procedure The EUT are Placed on a table which is 0.8 meter high above the ground. The
EUT is set 3 meters away from the transmitting antenna which is mounted on an
antenna tower. Both horizontal and vertical polanrization of the antennaare set on test.
Each of the four sides of the EUT must be faced this tranmitting antenna.and
measured individually.
In order to judge the EUT performance,a CCD camera is used to monitor its screen.
All the scanning conditions are as following:
Condition of Test Remark
1.Fielded Strength 3V/m(Severity Level 2)
2.Radiated Signal Modulated
3.Scanning Frequency 80-1000MHz
4.Sweep time of radiated 0.0015 Decade/s
5.Dwell Time 1Sec.
5.7Test Results
PASS.
Please refer to the following page..
Page 15 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC .Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
RF Field Strength Susceptiblity Test Results
SHENZHEN LCS CERTIFICATION SERVICES INC.
ETU :Car Charger Test Date : September 01, 2008
M/N :SQ-2210 Temperature : 22℃
Field Strength :3V/m Humidity :50%
Power Supply :5.2V Criterion : A
Test Mode : ON Frequency Range :80 MHz to 1000 MHz
Modulation: □None □Pulse □AM 1KHz 80%
Frequency Rang 1:
80~1000MHz
Frequency Rang 2;
Steps # / % # / %
Horizontal Vertical Horizontal Vertical
Front PASS PASS
Right PASS PASS
Rear PASS PASS
Left PASS PASS
Test Equipment :
1. Signal Generator :2023B(AEROFLEX)
2. Power Amplifier:ASO1025-55(MILMEGA)&AP32MT215(PRANA)
3. Log.-Per. Antenna: VULP9118E(SCHWARZBECK)
4. Broad-Band Horn Antenna: BBHA 9120L3F(SCHWARZBECK)]
5. RF Power Meter. Dual Channel:4232A(BOONTON)
6. Field Strength Meter: HI-6005(HOLADAY)
Note:
Page 16 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC . Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONICS CO., LTD
6.ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
6.1Block Diagram of Test Setup
6.1.1 Block Diagram of the EUT.
5.2V
(EUT:Car Charger)
6.1.2Block Diagram of the AC Mains.
AC Mains
EUT EFT/B Tester
0.8m
AC Mains
(EUT: Car Charger)
6.2 Test Standard
EN55024:1998+A1:2001+A2:2003
(EN61000-44:2004,Severity Level 1:0.5KW)
6.3Severity Levels and Performance Criterion
6.3.1Severity Level
Open Circuit Output Test Vlatage ±10%
Level On Power Supply
Lines
On /I/O(Input/Output
Signal data and control
lines)
1. 0.5KV 0.25KV
2. 1KV 0.5KV
3. 2KV 1KV
4. 4KV 2KV
X Special Special
6.3.2Performance criterion:B
Page 17 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC.Report No. LCS080830831E
EUT Load
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
6.4EUT Configuration The configuration of EUT are listed in Section 3.4.
6.5 Operating Condition of EUT 6.5.1 Setup the EUT as shown in Section 6.1.
6.5.2 Turn on the power of all equipments.
6.5.3 Let the EUT work in test mode(ON)and measure it.
6.6 Test Procedure The EUT is put on the table which is 0.8meter high above the ground. This reference
ground plan shall project beyond the EUT by at least 0.1m on all sides and the minimum
distance betwnne EUT and all other conductive structure ,except the ground plane beneath the
EUT,shall be more than 0.5m
6.6.1 For input and output AC power ports:
It’s unnecessary to test
6.6.2 For signal lines and control lines ports:
It’s unnecessary to test.
6.6.3 For DC Input line ports:
The EUT is connected to the DC power mains by using a coupling device which
couples the EFT interference signal to DC power lines. Both polarities of the test
voltage should be applied during compliance test and the duration of the test is 2
mins.
6.7 Test Result
PASS.
Please refer to the following page.
Page 18 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC .Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Electrical Fast Transient/Burst Test Results
SHENZHEN LCS CERTIFICATION SERVICES INC.
Standard
□ IEC61000-4-4
□ EN61000-4-4
Result: □PASS/ □ FAIL
EUT : Car Charger M/N:SQ-2210
Input Voltage : 5.2V
Criterion : B
Ambient Conditon : 22℃ 50%RH
Operation Mode:ON
Line : □ AC Mains Line: □ Signal □ DC Output Line
Coupling : □ Diret Coupling : □ Capacitive
Test Time : 120s
Lime Test Voltage Result(+) Result(-)
L
N
PE
L、N、PE
DC Input Line 0.5KV PASS PASS
Note:
Test Equipment Burst Tester Model :PEFT 4010
Page 19 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC.Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONICS CO., LTD
7.SURGE IMMUNITY TEST
7.1 Block Diagram of Test Setup
7.1.1 Block Diagram of the EUT.
5.2V
(EUT: Car Charger)
7.1.2Surge Test Setup.
AC Mains
0.8m
AC Mains
7.2 Test Standard EN55024:1998+A1:2001+A2:2003
(EN61000-4-5:2006 Severity Level: Level 1, 0.5KV)
7.3 Severity Levels and Performance Criterion
7.31. Severity level
Severity Level Open-Circuit Test Voltage
KV
1
2
3
4
*
0.5
1.0
2.0
4.0
Special
7.3.2 Performance criterion :B
7.4 EUT Configuraton
The configuration of EUT are listed in Section 3.4.
Page 20 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No. LCS080830831E
EUT Load
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
7.5 Operating Condition of EUT 7.5.1 Setup the EUT as shown in Section 7.1.
7.52 Turn on the power of all equipments.
7.5.3 Let the EUT work in test mode (ON) and measure it.
7.6 Test Procedure 1)Set up the EUT and test generator as shown on Section 7.1.2.
2) For DC port coupling mode, provide a 0.5KV 1.2/50us voltage surge
(at open-circuit condition)and 8/20us current surge to EUT selected points.
3)At least 5 plsitive and 5 negative(polarity)tests with a maximum 1/min
repetition rate are conducted during test.
4)Record the EUT operating sitation during compliance test and decide the EUT
immunity criterion for above each test.
7.7 Test Result
PASS.
Please refer to the following page.
Page 21 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC.Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Surge Immunity Test Results
SHENZHEN LCS CERTIFICATION SERVICES INC.
EUT :Car Charger Test Date : September 01,2008
M/N :SqQ-2210 emperature : 22℃
Power Supply :5.2V Humidity :50%
Test Mode :ON Criterion : B
Location Polarity Phase Angle Number of
Pulse
Pulse Voltage
(KV)
Result
DC port + 0° 5 0.5KV PASS
- 0° 5 0.5KV PASS
Remark:
Test Equipment:
Surge Tester Psurge4.1
Page 22 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONICS CO., LTD
8.INJECTED CURRENTS SUSCEPTIBILITY TEST
8.1 Block Diagram of Test Setup
8.1.1 Bolck Diagram of the EUT
5.2V
(EUT: Car Charger)
8.1.2 Block Diagram of Test Setup
EUT CDN AC Mains
0.1m
Ground Refence Support
(EUT: Car Charge )
8.2Test Standard EN55024:1998+A1:2001+A2:2003
(EN61000-4-6:1996+A1:2001,Severity Level :3V(rms)).(0.15MHz~80MHz)
8.3 Severity Levels and Performance Criterion 8.3.1 Severity level
Level Field Strength(rms)
1. 1
2. 3
3. 10
X Special
8.3.2 Performance criterion:A
Page 23 of 34
SHENZHNE LCS CERTIFICATION SERVICES INC. Report No.LCS080830831E
EUT Load
Power
Amplifier
Signal
Generato
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
8.4EUT Configuration The configuration fo EUT are listed in Section 3.4.
8.5 Operating Condition of EUT 8.5.1 Setup the EUT as shown in Section 8.1.
8.5.2 Turn on the power of all equipments.
8.5.3 Let the EUT work in test mode(ON)and measure it.
8.6 Test Procedure 8.6.1 For AC Mains
It’s unnecessary to teast.
8.6.2 For signal lines and control lines ports:
It’s unnecessary to test.
8.6.3 For DC Input line ports:
1)Set up the EUT,CDN and test generators as shown on Section 8.1.
1)Let the EUT work in test mode and measure it.
2)The EUT are placed on an insulating support 0.1m high above a ground
reference plane. CDN(coupling and decoupling network)is placed on the
ground plane about 0.3mf rom EUT. Cables between CDN and EUT are as short as
possible,and their height above the ground reference plane shall be
betwwen 30 and 50mm(where possible) .
3)The disturbance signal describes below is injected to EUT through CDN.
4)The EUT operates within its operational mode(s) under intended climatic
conditions after power on.
5)The frequency range is swept from 150KHz to 80MHz using 3V signal level,
and with the disturbance signal 80% amplitude modulated with a 1KHz sine wave.
6)The rate of sweep shall not exceed 1.5*10��decades/s. Where the frequency is
swept incrementally,thestep size shall not nxceed 1% of the star and thereafter
1% of the preceding frequency value.
Recording the EUT operating situation during compliance testing and decide
the EUT immunity criterion.
8.7 Test Results
PASS
Please refer to the following page.
Page 24 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC .Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Injected Currents Susceptibility Test Results
SHENZHEN LCS CERTIFICA TION SERVICES INC,
ETU : Car Charger Test Date : September 01, 2008
M/N : SQ-2210 Temperature :22℃
Power Supply :5.2V Humidity :50%
Test Mode :ON
Frequency
Range(MHz)
Injected Position Strength
(unmodulated)
Criterion Resslt
0.15~80 DC input port 3V A PASS
Test Mode:
Frequency Range
(MHz)
Injected Position Strength
(Ybnidylated)
Criterion Result
Remark :1.modulation Signal :1KHz80% AM
Measurement Equipment:
Simulator:CWS 500(SWITZERLAND EMTEST)
CDN:□CDN-M2(SWITZERLAND EMTEST)
□CDN-M3(SWITZERLAND EMTEST)
Note:
Page 25 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No.LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONICS CO., LTD
9.MAGNETIC FIELD SUSCEPTIBILITY TEST
9.1 Block Diagram of Test
9.1.1 Block diagram of test setup.
5.2V
(EUT:CarCharger)
9.1.2 Magnetic field test setup.
Induction Coil
Induction Coil
EUT
0.1m AC Mains
Ground Reference Support
(EUT:Car Charger)
9.2 Test Standard EN55024:1998+a1:2001+A2:2003
(EN61000-4-8:1993+A1:2001, Severity Level:Level 2,3A.m)
9.3Severity Levels and Performance Criterion 9.3.1 Severity Levels
Level Field Strength A/m
1 1
2 3
3 10
4 30
5 100
X Special
9.3.2 Performance Criterion:A
Page 26 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC.Report No.LCS080830831E
EUT Load
wood
Magnetic
Field
AC
Transform
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
9.4EUT Configuration on Test
The configuration of the EUT is same as Section 3.4.
9.5 Test Procedure
The EUT is places in the middle of a induction coil (1*1m), under which is a
1*1*0.1m(high)table,this small table is also placed on a larger table,0.8m above
the ground. Both horizontal and vertical polarization of the induction coil are set
on test,so that each side of the EUT is affected by the magnetic field. Also can
reach the same aim by change the position of the EUT.
9.6 Test Results
PASS
Please refer to the following page.
Page 27 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC.Report No. LCS080830831E
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Mannetic field Immunity Test Result
SHENZHEN LCS CERTIFICATION SERVICES INC.
Standard □ IEC 61000-4-8
□ EN 61000-4-8
Result:□Pass/□Fais
ETU : Car Charger M/N : SQ-2210
Input Voltage : 5.2V
Date of Test : September 01,2008 Test Engineer. ANDY
Ambient Condition : Temp :22℃ Humid: 55%
Criterion :A
Operation Mode :ON
Test Level
(A/M)
Testing
Duration
Coil
Orientation
Criterion Result
1 5 mins X A PASS
1 5 mins Y A PASS
1 5 mins Z A PASS
Operation Mode :
Test Level
(A/M)
Testing
Duration
Coil
Orientation
Criterion Result
Test
Equipment
Mangnetic Field Test : HEAFELY MAG 100.1
Note:
Page 28 of 34
SHENZHEN LCS CERTIFICATION SERVICES INC. Report No.LCS080830831E
10.PHOTOGRAPH
Generated by Foxit PDF Creator © Foxit Softwarehttp://www.foxitsoftware.com For evaluation only.
Applicant SOO ELECTRONICS CO., LTD