  • 8/11/2019 EN26_prA2_FV

    1/19

    EUROPEAN STANDARD

    NORME EUROPENNE

    EUROPISCHE NORM

    FINAL DRAFTEN 26:1997

    prA2December 2003

    ICS 91.140.65

    English version

    Gas-fired instantaneous water heaters for the production ofdomestic hot water, fitted with atmospheric burners

    Appareils de production instantane d'eau chaude pourusages sanitaires, quips de brleurs atmosphriques,

    utilisant les combustibles gazeux

    Gasbeheizte Durchlauf-Wasserheizer fr den sanitrenGebrauch mit atmosphrischen Brennern

    This draft amendment is submitted to CEN members for formal vote. It has been drawn up by the Technical Committee CEN/TC 48.

    This draft amendment A2, if approved, will modify the European Standard EN 26:1997. If this draft becomes an amendment, CENmembers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendmentinto the relevant national standard without any alteration.

    This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language madeby translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same statusas the official versions.

    CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and UnitedKingdom.

    Warning: This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice andshall not be referred to as a European Standard.

    EUROPEAN COMMITTEE FOR STANDARDIZATIONC O MIT EU R O PEN D E N O R MA LISA TIO NEU R O P ISC H ES K O MITEE F R N O R MU N G

    Management Centre: rue de Stassart, 36 B-1050 Brussels

    2003 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.

    Ref. No. EN 26:1997/prA2:2003 E

  • 8/11/2019 EN26_prA2_FV

    2/19

    EN 26:1997/prA2:2003 (E)

    2

    Contents

    Foreword......................................................................................................................................................................3

    1 Scope...............................................................................................................................................................4

    2 Normative references ....................................................................................................................................43.7 combustion circuit.........................................................................................................................................43.7.5 terminal ...........................................................................................................................................................44.3 mode of supply of the combustion air and evacuation of the combustion products

    (appliance type) ..............................................................................................................................................44.3.2 Type B .............................................................................................................................................................45.1 Appliance marking .........................................................................................................................................6

    5.1.4 Warnings on the appliance and the packaging ..................................................................................6

    5.2 Instructions.....................................................................................................................................................65.2.1 Technical instructions...................................................................................................................................66.1.7 Supply of combustion air and evacuation of the combustion products..................................................76.2.10 Combustion products discharge safety device..........................................................................................77.2.1 Soundness of the gas circuit........................................................................................................................87.7.2 Supplementary tests for appliances of types AAS and B11 and B11BS ...............................................107.7.5 Supplementary tests for appliances of types C12 C13 C32 and C33.....................................................107.7.12 Air proving device for type C water heaters with fan...............................................................................107.7.16 Supplementary tests for type B14, B2 and B3water heaters.....................................................................117.9 Combustion ..................................................................................................................................................117.9.1 Requirements ...............................................................................................................................................11

    Annex A......................................................................................................................................................................12

    Annex B (normative).................................................................................................................................................13

    Annex N (informative) Schematic representation of the classification of type B water heaters.....................14

    Annex ZA....................................................................................................................................................................19

  • 8/11/2019 EN26_prA2_FV

    3/19

    EN 26:1997/prA2:2003 (E)

    3

    Foreword

    This document EN 26:1997/prA2:2003 has been prepared by Technical Committee CEN/TC 48 Domestic gas-fired water heaters, the secretariat of which is held by AFNOR.

    This document is currently submitted to the Formal Vote.

    This document has been prepared under a mandate given to CEN by the European Commission and theEuropean Free Trade Association, and supports essential requirements of EU Directive(s).

    For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.

    With this amendment, the requirements and test methods for type B instantaneous water heaters with fanassisted combustion are introduced in EN 26. In addition requirements and test procedures for resistance tofreezing are introduced.

  • 8/11/2019 EN26_prA2_FV

    4/19

    EN 26:1997/prA2:2003 (E)

    4

    1 Scope

    2nd

    paragraph 1stdash, add: "B12, B12BS, B13, B13BS, B14, B22, B23, B32, B33, B44, B52and B53"

    2

    nd

    paragraph 1

    st

    dash, add the following footnote :

    "National installation regulations may specify further requirements and may limit the modes ofinstallation permitted in the territory of a CEN member state.

    2nd

    paragraph 3rd

    dash, delete :"hereafter referred to as type C water heaters with a fan".

    4thparagraph, add the following indent :

    "water heaters of types B21, B31, B41, B42, B43and B51;"

    Add after the 4thparagraph :

    This standard only covers water heaters where the fan, if any, is an integral part of the appliance.

    2 Normative references

    Add the following reference :

    "CR 1749 : 2001 European scheme for the classification of gas appliances according to themethod of evacuation of the products of combustion (Types)."

    3.7 combustion circuit

    Replace the last dash with the following :

    "the combustion products evacuation ducts and either the duct adapter (if any) or the connectionto the terminal for type C, B4and B5water heaters."

    3.7.5 terminal

    Add after the 3rd

    indent : " the combustion products evacuation duct for types B4 and B5 waterheaters."

    4.3 mode of supply of the combustion air and evacuation of the combustionproducts (appliance type)

    4.3.2 Type B

    Add after the first paragraph the following text:

    "Type B water heaters are classified into several types according to the mode of evacuation of thecombustion products.

    The types are defined by two subscripts:

    a) The first subscript number is based upon the possible installation of the water heater with respectto the mode of air supply and evacuation of the combustion products.

    b) The second subscript number is based upon the presence and position of an integral fan in thewater heater, as shown below :

  • 8/11/2019 EN26_prA2_FV

    5/19

    EN 26:1997/prA2:2003 (E)

    5

    A type B water heater that does not incorporate a fan is identified by the second subscript number1 (e.g. B11).

    A type B water heater designed for a natural draught flue incorporating a fan downstream of thecombustion chamber/heat exchanger and upstream of the draught diverter is identified by thesecond subscript number 2 (e.g. B12).

    A type B water heater that incorporates a fan upstream of the combustion chamber/ heatexchanger is identified by the second subscript number 3 (e.g. B23).

    A type B water heater that incorporates a fan downstream of both the combustion chamber/ heatexchanger and the draught diverter is identified by the second subscript number 4 (e.g. B14).

    A type B water heater intended to operate with a pressurised flue duct shall be identified by an extrasubscript P. This subscript P is only used when installation in accordance with the water heatermanufacturers instructions on a flue specified by the water heater manufacturer results in the flueoperating at a positive pressure4).

    Add at the end of the last paragraph of subclause 4.3.2 a new footnote :

    This identification P is in accordance with the designation of the classes of tightness in positivepressure, agreed by CEN/TC 166: "Chimneys", depending on the pressure of operation of the duct(e.g. see EN 1443).

    Add the following new subclauses :

    "4.3.2.2 type B2

    A type B water heater without a draught diverter.

    4.3.2.3 type B3

    A type B water heater without a draught diverter, which is designed for connection to a common ductsystem. This common duct system consists of a single natural draught flue. All pressurised parts ofthe water heater containing products of combustion are completely enclosed by parts of the waterheater supplying combustion air. Combustion air is drawn into the water heater from the room bymeans of a concentric duct, which encloses the flue. The air enters through defined orifices situated inthe surface of the duct

    4.3.2.4 type B4

    A type B water heater incorporating a draught diverter, that is designed for connection via its flue ductto its flue terminal.

    4.3.2.5 type B5

    A type B water heater without a draught diverter, that is designed for connection via its flue duct to itsflue terminal.

    4.3.2.6 presence and position of a fan

    A type B water heater that does not incorporate a fan is identified by the second subscript number"1" (e.g. B11).

    A type B water heater that incorporates a fan downstream of the combustion chamber/ heat

    exchanger and upstream of the draught diverter, if any, is identified by the second subscriptnumber "2" (e.g. B12).

  • 8/11/2019 EN26_prA2_FV

    6/19

    EN 26:1997/prA2:2003 (E)

    6

    A type B water heater that incorporates a fan upstream of the combustion chamber/ heatexchanger is identified by the second subscript number "3" (e.g. B13).

    A type B water heater that incorporates a fan downstream of both the combustion chamber/ heatexchanger and the draught diverter is identified by the second subscript number "4" (e.g. B14).

    5.1 Appliance marking

    5.1.4 Warnings on the appliance and the packaging

    5.1.4.3 For type B11appliances

    Replace the title by: For type B11B12and B13 appliances.

    5.1.4.4 For type AASand type B11BSappliances

    Replace the title by: For type AAS, B11BSB12BSand B13BS appliances.

    5.2 Instructions

    5.2.1 Technical instructions

    Change in 5.2.1.4 and 5.2.2.3B11BS toB11BS, B12BS, B13BS.

    Add the following subclause:

    f) for type B2appliances

    the diameter(s) of the flues which can be used, in accordance with A.9, possibly with an adapter;

    for flue calculations, information on the mass rate of combustion products in g/s and the averagetemperature measured under the conditions of 8.2.2.

    g) for types B4and B5appliances

    information about the type of installation for which the water heater is approved;

    give the instruction that the water heater has to be installed with the necessary accessories (e.g.ducts, terminal, fitting piece) supplied with the water heater or give the specification of thenecessary accessories that shall be fitted;

    give the instruction for the installation of parts intended to be fitted to the water heater;

    indicate the maximum number of bends to be used and the maximum length and, if necessary,the minimum length of the air supply and combustion products evacuation ducts;

    give the particular characteristics of the terminal guard, where provision for this is made, andinformation on its installation relative to the terminal.

  • 8/11/2019 EN26_prA2_FV

    7/19

  • 8/11/2019 EN26_prA2_FV

    8/19

    EN 26:1997/prA2:2003 (E)

    8

    by

    in this case, they are designated as type B11, B12or B13

    7.1.5.2 Installation requirements

    Replace in the third paragraphA type B11or B11BSappliance by A type B appliance (except for typesB4and B5)

    Add the following paragraphs:

    Type B4 and B5water heaters are tested with their ducts and terminals. The terminal guard is notfitted.

    Except where otherwise stated, water heaters of types B4and B5are connected to the shortest ductswith the smallest pressure loss stated by the manufacturer in his installation instructions. If necessary,an external telescopic duct may be sealed in accordance with the manufacturers instructions."

    7.2.1 Soundness of the gas circuit

    7.2.1.1 Requirement

    At the third indent of the second paragraph, replace: test n3 by: test n3 and test n4

    7.2.1.2 Test

    Add the following text:

    Test n4

    The pressure upstream of the water heater is 50 mbar for water heaters that do not use third familygases, and 150 mbar for water heaters that do use third family gases.

    The flame supervision device is held open by an appropriate means. If necessary, the gas supplycircuit of the pilot is blocked off.

    The water heater is connected to a water supply at the maximum pressure declared by themanufacturer.

    All the blockage devices of the gas circuit are held open except for the device(s) directly controlled bythe water rate.

    The ambient temperature of air around the water flow sensing device is lowered at approximately

    1 C/min down to a temperature of -10 C during a time sufficient to obtain the freezing of the device.

    In the case where after thaw the water heater has not suffered any visible damage, test n1, n2 andn3 of 7.2.1.2, and test n1 of 7.7.1.2 are carried out.

    Add the following subclause:

    7.2.2.4 Type B appliances other than B11, B11BSand B3

    7.2.2.4.1 Requirement

    The soundness is ensured if, under the test conditions of 7.2.2.4.2, combustion products only escape

    from the flue outlet.

    The ducts of type B5water heaters shall also meet the requirements of 7.2.2.6.

  • 8/11/2019 EN26_prA2_FV

    9/19

    EN 26:1997/prA2:2003 (E)

    9

    7.2.2.4.2 Test

    The maximum pressure at which the water heater can operate is determined by progressivelyblocking the combustion products evacuation duct or air inlet, until the air proving device acts.

    The air proving device is then put out of operation, to allow the operation of the burner at themaximum cut-off pressure of the air proving device.

    The water heater is connected to its shortest length of flue duct incorporating a restriction to reach themaximum operating pressure determined above.

    Possible leaks are looked for with a dew point plate, whose temperature is maintained at a valueslightly above the dew point of the ambient air. The plate is brought close to all the places where aleak is suspected.

    In doubtful cases, however, leaks are looked for with a sampling probe connected to a rapid-responseCO2-analyser enabling concentrations of the order of 0,20 % to be detected.

    In this case, precautions shall be taken to ensure that sampling does not interfere with the normalevacuation of the combustion products.

    It is checked that the requirement of 7.2.2.4.1 is satisfied.

    7.2.2.5 Type B3water heaters

    7.2.2.5.1 Requirement

    Soundness is ensured if under the test conditions of 7.2.2.5.2 by choice of the manufacturer:

    the leakage rate of the combustion products circuit does not exceed 3,0 m3/h;

    the leakage rate of the combustion circuit (with all the duct and joints) does not exceed 5,0 m3/h.

    7.2.2.5.2 Test

    Connect the outlet of the flue duct to a pressure source. Block the orifices in the surface of theconcentric duct through which air is supplied.

    The test pressure is to be at least 0,5 mbar.

    It is verified that the requirements of 7.2.2.5.1 are met.

    7.2.2.6 Combustion products evacuation ducts of type B4and B5water heaters

    7.2.2.6.1 Requirement

    The soundness of a combustion products evacuation duct supplied by the manufacturer, notcompletely surrounded by combustion air, with respect to areas other than where the water heater isinstalled, is ensured if under the test conditions of 7.2.2.6.2 the leakage rate per square meter surfaceof the duct does not exceed 0,006 dm3/s.

    7.2.2.6.2 Test

    The test shall check all the joints declared by the manufacturer, between:

    the water heater and its ducts;

    interconnecting ducts;

  • 8/11/2019 EN26_prA2_FV

    10/19

    EN 26:1997/prA2:2003 (E)

    10

    the ducts and any bends; and

    the ducts and any fitting piece or terminal.

    In the case that leakage can occur along the length of the ducts, the tests are also carried out with themaximum length of ducts.

    In accordance with the technical instructions, the wall connections, the joint with the terminal or thejoint with the fitting piece with another system of combustion products evacuation may be madesound.

    The flue duct and its joint to the water heater are connected to a pressure source on one side andblocked on the other side with a pressure corresponding to the maximum pressure measured in7.2.2.4.2.

    It is checked that the requirement of 7.2.2.6.1 is met.

    7.7.2 Supplementary tests for appliances of types AAS and B11 and B11BS

    Replace the title by: Supplementary tests for appliances of types AASand B1except for B14.

    7.7.5 Supplementary tests for appliances of types C12 C13 C32 and C33

    Replace the title by:Supplementary tests for appliances of types C12C13C32C33B4and B5.

    7.7.12 Air proving device for type C water heaters with fan

    Replace the title by:Air proving device for fan assisted water heaters.

    Add a new subclause as follows:

    7.7.12.5 Supplementary test for type B water heaters with draught diverter

    7.7.12.5.1 Requirement

    Under the specific test conditions of 7.7.12.2, 7.7.12.3.2 or 7.7.12.4.3.2, combustion products shallescape only from the flue outlet.

    7.7.12.5.2 Test

    For type B water heaters with fan and draught diverter, the following tests are carried out:

    With the water heater at ambient temperature, the flue outlet is fully blocked. The water heater isset to ignite and the blockage is progressively removed. At the point where ignition occurs, theabsence of spillage is checked.

    The flue outlet is unblocked and the water heater is operated at thermal equilibrium. The flueoutlet is then progressively blocked. It is verified that at least safety shutdown occurs beforespillage is detected.

    Spillage is looked for with a dew point plate whose temperature is maintained at a value slightlyabove the dew point of the ambient air. The plate is brought close to all places around thedraught diverter where a leak is suspected.

    In doubtful cases, however, leaks are looked for with a sampling probe connected to a rapid-response CO2analyser, enabling contents of the order of 0,2 % to be detected.

  • 8/11/2019 EN26_prA2_FV

    11/19

    EN 26:1997/prA2:2003 (E)

    11

    Where the water heater operates at different fan speeds, the test is repeated at the lowest fanspeed and the appropriate gas rate. The water flow and return temperatures may be adjusted toachieve this condition.

    7.7.16 Supplementary tests for type B14, B2 and B3water heaters

    7.7.16.1 Requirement

    Under the test conditions of 7.7.16.2, no extinction of the burner is permitted. The flames shall bestable. Nevertheless, during the tests, a slight tendency to lift is allowed. Shut down by the action ofthe device monitoring the air supply or combustion products evacuation is allowed.

    7.7.16.2 Test

    The tests are carried out with an appropriate reference gas for the water heater category at thenominal heat input and the minimum heat input given by the controls, if such operation is intended bythe manufacturer.

    The water heater is installed with the test flue. The flue outlet is progressively blocked. lt is checkedthat the requirements of 7.7.16.1 are satisfied, at the moment that the pressure at the flue outlet of thewater heater has reached the value of 50 Pa.

    For water heaters intended to operate with a pressurised flue duct, designated by a P, this value israised by the maximum nominal overpressure declared by the manufacturer, which shall not begreater than 200 Pa.

    7.9 Combustion

    7.9.1 Requirements

    Replace "and 7.9.2.3.12" by "7.9.2.3.12, 7.9.2.3.13 and 7.9.2.3.14".

    7.9.2.2 Test in still air

    After the 1stparagraph, add the following paragraph :

    A type B4or B5water heater is fitted with the longest flue duct declared by the manufacturer.

    For water heaters intended to operate with a pressurised flue duct, designated by a P, the flue outletof the water heater is exposed to the maximum nominal overpressure declared by the manufacturer,which shall not be greater than 200 Pa. This pressure may be achieved by partial blockage of theflue.

    7.9.2.3.1 Type B11and B11BSappliances

    Replace the title by :"Type B1appliances except for B14".

    At the 5thparagraph replace: " B11BS" by"B11BS, B12BS, B13BS".

    Add the following subclauses:

    7.9.2.3.13 Type B14, B2and B3, water heaters

    In the test conditions of 7.7.16.2, it is checked that the requirements of 7.9.1 b) are met.

    7.9.2.3.14 Type B4and B5 water heaters

    In the test conditions of 7.7.5 it is checked that the requirements of 7.9.1 b) are met.

  • 8/11/2019 EN26_prA2_FV

    12/19

    EN 26:1997/prA2:2003 (E)

    12

    Annex A(informative)

    Table A.7, in the column "other categories - threaded connection" : replace ISO 224-1 by ISO 228-1.

  • 8/11/2019 EN26_prA2_FV

    13/19

    EN 26:1997/prA2:2003 (E)

    13

    Annex B(normative)

    Modify the title to: Test apparatus for type C1,C3,B4and B5water heaters.

    Modify the title of Figure B.1 to: Test apparatus for type C1B4and B5water heaters fitted with a

    horizontal terminal installed on a vertical wall.

    Modify the title of Figure B.2 to: Test apparatus for type C1B4and B5water heaters fitted with a

    horizontal terminal installed on an inclined wall.

    Modify the title of Figure B.3 to: Test apparatus for type C3B4and B5water heaters fitted with a

    vertical terminal installed on a horizontal wall.

    Modify the title of Figure B.4 to: Test apparatus for type C3B4and B5water heaters fitted with a

    vertical terminal installed on an inclined wall.

    Add a new annex N as follows:

  • 8/11/2019 EN26_prA2_FV

    14/19

    EN 26:1997/prA2:2003 (E)

    14

    Annex N(informative)

    Schematic representation of the classification of type B water heaters

    The figures in this annex are purely illustrations. They are neither intended to be technically perfect nor complete inthemselves.

    Type B4and B5water heaters differ from B1and B2respectively, only in the fact that their flue ducts and terminalsare integral parts of these water heaters.

  • 8/11/2019 EN26_prA2_FV

    15/19

    EN 26:1997/prA2:2003 (E)

    15

  • 8/11/2019 EN26_prA2_FV

    16/19

    EN 26:1997/prA2:2003 (E)

    16

  • 8/11/2019 EN26_prA2_FV

    17/19

  • 8/11/2019 EN26_prA2_FV

    18/19

    EN 26:1997/prA2:2003 (E)

    18

    Key

    a) Type B11b) Type B12c) Type B13d) Type B14

    e) Type B21(not covered by this standard)f) Type B22g) Type B23h) Type B32i) Type B33j) Type B41k) Type B42l) Type B43m) Type B44n) Type B44o) Type B51p) Type B52q) Type B52r) Type B53s) Type B53

  • 8/11/2019 EN26_prA2_FV

    19/19

    EN 26:1997/prA2:2003 (E)

    Annex ZA(informative)

    Clauses of this European standardAddressing the provisions of the EU Directive Gas Appliances 90/396

    Into the third column of Table ZA.1, add the following clauses :

    EssentialRequirements

    ObjectClauses and/or paragraphs in theEuropean Standard which complywholly or in part with the Essential

    Requirements

    1 ANNEX I of the Directive EU

    GENERAL CONDITIONS

    1.1 Safety operation 1, 2, 7.1.5.2

    1.2 Marking and instructions

    Installations instruction

    Warnings on the appliance

    5.2.1

    5.1.4

    1.2.1 Information in the installation instructions 5.2.1

    1.2.3 Warnings on the appliance and packaging 5.1.4

    3.2

    3.2.1

    Unburned gas release

    Risk of gas leakage 7.2.1

    3.4

    3.4.1

    Combustion

    Flame stability

    Concentration of substances harmful to health in thecombustion

    7.7

    6.1.7, 7.9

    3.4.2 Release of combustion products 7.2.2.4