OEC Product Catalogue
Enclosures and empty enclosures
Encl
osur
es a
nd e
mpt
y en
clos
ures
64
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/C1MENCLOSURE for EXTERNAL APPLICATION 200x500
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught Resistance in accordance with regulations IEC 60112 - PTI
500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accordance
with CEI EN 62262.• In compliance with Specification: nr. Enel 282226 for Lombardy and nr. Enel
282216 for Triveneto.
General characteristics:• Designed for the installation of integrated mono-phase meters GMI-type
up to 10 KW.• Smooth, hinged door with a 90° opening which is removable for easier
access. • A transparent inspection window for doors is also available. • One-point lock. The lock can be supplied with a triangular key, a cross key
or a Yale-type key upon request. • The enclosure includes a bipolar terminal block for 6 mm2 cable connection
and branching. • Suitable for wall or pole mounting with stainless steel attachment and
bracket. • Two holes are located at the bottom for the passing of cables.
Accessories:• 19000168 - Spare door.• 19000170 - Spare door with inspection window.• 19000454 – Locks series SC/T2 (pag. 146).• See table – Locks series SC/YL (pag. 143).• 19000644 – Locks series SC/T1L (pag. 145).• See table – Locks series SC/SL (pag. 141)• 15638700 - Hinge.• 15638711 - Hinge pin.• S038420W - Pole mounting bracket (pag.101).
Width (mm) Height (mm) Depth (mm)
Overall dimensions 195 500 185
Internal dimensions 170 488 150
Code DescriptionBoardENEL
S03742GW Lock with triangular key and padlock latch Enel Lombardy 2822 C
SV37421W With cross key lock coding Enel Veneto 2822 GSV37422W With cross key lock coding Enel Friuli Venetia Giulia 2822 GSV37423W With cross key lock coding Enel Trentino Alto Adige 2822 G
SM3942GK With window, lock with triangular key and padlock latch -
SV3742SK Without lock -
ARE/C1M
195 185
500
Encl
osur
es a
nd e
mpt
y en
clos
ures
65
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/GMI-Y UnifiedENCLOSURES for GMI/GMY
Article Code: N0ST0117
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80
Points.• Surface draught resistance in accordance with regulations IEC 60112:
PTI 500.• Impact resistance10J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• See Specification Enel: DS 4555 (National) nr. Enel 284033.
General characteristics:• Predisposition for the installation of: 1) An integrated mono-phase meter GMI-type Y. 2) An electronic mono-
phase meter GEM-type via T5A2 board. 3) An electronic three-phase meter up to 15 KW GET-1 or GET-2A-type with T5A4 board. 4) Other applications via base plate.
• Textured door, hinged allowing a 90° opening which is removable for easier access.
• Internal ventilation obtained by means of a conduit along the door pe-rimeter
• The lock is Enel type 4541 (Italian national standards) allowing indepen-dent inspection by multiple users.
• The enclosure is fit for wall-installation, pole installation or on fibreglass Enel DS 4553 type pole.
• It is possible to personalise the colour and add trademarks upon re-quest.
Accessories:• N2ST0159 - Textured spare door (with Enel logo) (pag. 224).• N2ST0242 - Textured spare door (blank logo).• N1ST0558 - Bakelite base plate thickness 4 mm.• For further ACCESSORIES, specifications and spare parts relative to the
series ARE/GMI, see pag. 68.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 230 420 204
Internal dimensions 183 373 175
Code Description
N0ST0117/12 Enclosure blank logo with lock coding 12
N0ST0117/21 Enclosure blank logo with lock coding 21
N0ST0117/N Enclosure blank logo
N0ST0117/NW Enclosure without lock, blank logo
ARE/GMI-Y UNIF.
Encl
osur
es a
nd e
mpt
y en
clos
ures
66
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/GMI-YENCLOSURE for GMI/GMY
Article Code: N0ST0361
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance10J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• See Enel Specification: DS 4551 (National). Nr. Enel 284013 without bracket.
General characteristics:• Predisposition for the installation of: 1) An integrated mono-phase meter GMI-type - Y. 2) An electronic mono-
phase meter GE-type via board T5A2. 3) An electronic three-phase meter up to 15 KW GET-1 or GET-2A-type with T5A4 board. 4) Other applica-tions via base plate.
• Textured door, hinged with a 90° opening which is removable for easier access.
• Internal ventilation obtained by means of a conduit along the door peri-meter.
• The lock is Enel type 4541 (Italian national standards) allowing indepen-dent inspection by multiple users.
• The enclosure is fit for wall-installation, pole installation or on fibreglass Enel DS 4553 type pole.
• It is possible to personalise the colour and add trademarks upon request.
Accessories:• N2ST0343 - Textured spare door (with Enel logo).• N2ST0343N - Textured spare door (blank logo).• N1ST0558 - Bakelite base plate thickness 4 mm.
• For further ACCESSORIES, specifications and spare parts relative to the series ARE/GMI, see pag. 68.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 230 420 204
Internal dimensions 183 373 175
ARE/GMI-Y
Encl
osur
es a
nd e
mpt
y en
clos
ures
67
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/GTI-Y UnifiedENCLOSURE per GTI/GTY
Article Code: N0ST0120
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80
Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance10J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• See Enel Specifications: DS 4556 (National) nr. Enel 284043.
General characteristics:• Predisposition for the installation of: 1) Two integrated mono-phase meters GMI-type - Y. 2) One three-phase
meter GTI-type - Y. 3) Two electronic mono-phase meters GEM-type with two T5A2 boards. 4) Two electronic three-phase meters up to 15 KW GET-1 or GET-2A-type with two T5A4 boards. 5) Other application via base plate.
• Textured door, hinged with a 90° opening which is removable for easier access.
• Internal ventilation obtained by means of a conduit along the door peri-meter.
• The lock is Enel type 4541 (Italian national standards) allowing indepen-dent inspection by multiple users.
• The Enclosure can be assembled on walls, poles or on fibreglass Enel DS 4553 type poles.
• It is possible to personalise the colour and add trademarks upon request.
Accessories:• N2ST0160 - Textured spare door (with Enel logo).• N2ST0241 - Textured spare door (blank logo).• N1ST0557 - Bakelite base plate 4 mm.
• For further Accessories, specifications and spare parts relative to the series ARE/GTI, see pag. 68.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 390 420 235
Internal dimensions 342 373 195
Code Description
N0ST0120/12 Locked enclosure blank logo coding 12
N0ST0120/21 Locked enclosure blank logo coding 21
N0ST0120/N Enclosure blank logo
N0ST0120/NW Enclosure without lock, blank logo
ARE/GTI-Y
Encl
osur
es a
nd e
mpt
y en
clos
ures
68
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/GMI-Y e GTI-Y ACCESSORIES for GMI/GTI
Locks, poles and hinges
Code
N0SF0010 Lock series SC/1 (pag. 159)
N0SF0011 Lock series SC/T (pag. 158)
S4541Y12 Lock with coding 12 series SC/12 (pag. 160)
S4541Y21 Lock with coding 21 series SC/21 (pag. 160)
PALETNAZ Adjustable rods kit
N0SF0009 Hinge
Accessories for installation
Code
N0ST0207 Pole mounting bracket (pag.100)
T0PO0017 Fibreglass pole for PL/AREC series enclosures (pag. 210)
Encl
osur
es a
nd e
mpt
y en
clos
ures
69
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/AENCLOSURE 500x500
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI 500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accordan-
ce with CEI EN 62262.• In compliance with Enel Specifications: nr.. Enel 282225 for Lombardy, nr.
Enel 282217 for Triveneto.
General characteristics:• Predisposition for the installation of: 1) Three integrated mono-phase meters GMI-type- Y. 2) One three-phase
meter GTI-type- Y. 3) Three electronic mono-phase meters GEM-type via Z3M board with three T2A2 boards. 4) One electronic three-phase meter up to 15 KW GET-1 or GET-2A-type via Z2M board with T4A4. 5) One electronic mono-phase meter GEM-type via Z1M board with T2A2, plus one electronic three-phase meter up to 15 KW GET-1 or GET-2A type via Z2M board with T4A4. 6) Other application via base plate.
• Smooth door, hinged, with a 90° opening which is removable for easier access.
• This door can be supplied with transparent window.• Three-point lock with padlock latch. Upon request it may be supplied with
triangular key lock, cross key, Yale-type key or National type.• Internal ventilation obtained via conduit between the cover and the sides. • Fit for wall mounting, pole mounting with bracket, floor mounting with fra-
me or base mounting with plate (see Accessories).• the bottom side of the enclosure consists of two semi-panels with three
rubber-sealed holes for cable passage and protection. • Standard unit is supplied with a closed base and cable passage holes (except
for the version without a cover which has an open base).
Accessories:• For further ACCESSORIES, specifications and spare parts relative to the
series ARE/A, see pag.72.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 540 550 305
Internal dimensions 515 520 255
Code DescriptionBoardENEL
S03741GW Lock with triangular key and padlock latch Enel Lombardy 2822 ASL3741GW With padlock latch -SY37410K Blank logo with lock coding 21 -SY37412K Blank logo with lock coding 12 -S03941GW With window and padlock latch -S03741NZ With lock SC/1-type - textured -S03741SK Without lock or window -S03741ST Without top, without lock, with coupling plate -
550
540 305
ARE/A
Encl
osur
es a
nd e
mpt
y en
clos
ures
70
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/A-BSENCLOSURE 500x500 MOUNTED on BASE
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI 500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accordan-
ce with CEI EN 62262.• In compliance with Enel Specifications: nr.. Enel 282225 for Lombardy, nr..
Enel 282217 for Triveneto.
General characteristics:• Predisposition for the installation of: 1) Three integrated mono-phase meters GMI-type- Y. 2) One three-phase
meter GTI-type- Y. 3) Three electronic mono-phase meters GEM-type via Z3M board with three T2A2 boards. 4) One electronic three-phase meter up to 15 KW GET-1 or GET-2A-type via Z2M board with T4A4. 5) One elec-tronic mono-phase meter GEM-type via Z1M board with T2A2, plus one electronic three-phase meter up to 15 KW GET-1 or GET-2A type via Z2M board with T4A4. 6) Other application via base plate.
• Smooth door, hinged with a 90° opening which is removable for easier access.
• This door can be supplied with transparent window. • Three-point lock with padlock latch. The lock can be supplied with a trian-
gular key, a cross key or Yale-type or National key upon request.• Ventilation obtained via conduit between the cover and the sides.• The enclosure is designed for floor mounting via Enel DS 4548-type base
and includes frame N1ST0192.
Accessories:• For further ACCESSORIES, specifications and spare parts relative to the
series ARE/A-BS, see pag. 72.
Code Description
S04741GK Lock with triangular key and padlock latch Enel LombardyS04741SL With padlock latch onlyS4741Y12 Blank logo with Lock coding 12S4741Y21 Blank logo with Lock coding 21S04741NZ With lock SC/1-type - texturedS04741SK Without lock
Width (mm) Height (mm) Depth (mm)
Internal dimensions (Enclosure) 515 520 255
Internal dimensions(Base) 310-490 550 180
Overall dimensions(Enclosure + Base) 540 1130 305
540 305
1130
ARE/A-BS
Encl
osur
es a
nd e
mpt
y en
clos
ures
71
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/A-SSENCLOSURE 500x500 STACKED
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI
500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accor-
dance with CEI EN 62262.• In compliance with Enel Specifications: nr. Enel 282225 for Lombardy, nr. Enel 282217 for Triveneto.
General characteristics:• Enclosure stacked on identical unit to double the amount of available space. • Smooth door, hinged with a 90° opening which is removable for easier
access. • This door can be supplied with transparent window.• Three-point lock with padlock latch. The lock can be supplied with a trian-
gular key, a cross key or Yale-type or National upon request.• Ventilation obtained via conduit between the cover and the sides.• Predisposition for floor mounting with appropriate frame or a base with
corresponding plate (see Accessories).• Standard supply is with open base.
Accessories:• For further Accessories, specifications and spare parts relative to the series
ARE/A-SS, see pag. 72.
Code Description
S05741GW Lock with triangular key and padlock latch Enel Lombardy
SL5741GW With padlock latch only
SY5742GK With lock coding 12 upper and lowerSY5741GK With lock coding 12 upper., coding 21 lowerSY5741GW With lock coding 21 upper and lower
S05741NZ With lock SC/1-type upper. And lower. - textured
S05741SS Without lock
Width (mm) Height (mm) Depth (mm)
Overall dimensions 540 1080 305
Internal dimensions(Single enclosure)
515 520 255
540 305
1080
ARE/A-SS
Encl
osur
es a
nd e
mpt
y en
clos
ures
72
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/AACCESSORIES for ENCLOSURE 500x500
Accessories for racking equipment
Code
N1ST0260
Base frame including modular racking panels (see note)
• Mounting kit for racking equipment (See picture)
• N° 2 Perforated panels 466x149 mm (See picture)• N°1 Blank panel 466x149 mm (See picture)
Note:It is possible to vary the composition of panels assembled on the mounting kit.
Racking equipment components
Code
N2SF0155 Blank panel 466x149 mm•Panel• Mounting kit
N2SF0157 Perforated panel 466x149 mm • Racking equipment mounting kit
N1ST0366Base frame for racking equipment
• Left and right angle bars• Mounting kit
N1ST0371 Inner door (see note) • Door• Mounting kit
Locks, poles and hinges
Code19000454 Lock series SC/T2 (pag. 162)19000644 Lock series SC/T1L (pag. 163)See table Locks series SC/SL (pag. 165)See table Locks series SC/YL (pag. 164)S63790AW Locks series SC/ML padlock latch closure only (pag. 161)N0SF0010 Lock series SC/1 (pag. 159)N0SF0011 Lock series SC/T (pag. 158)S4541Y12 Lock with coding 12 series SC/12 (pag. 160)S4541Y21 Lock with coding 21 series SC/21 (pag. 160)PALET500 Enclosure rod kit 500x500PALETNAZ Enclosure rod kit 500x500 with national door19000133 Hinge mounting plate19000134 Hinge15627590 Hinge pin
Note:The inner door cannot be assembled without respective frame and panels, cod. N1ST0260.
Encl
osur
es a
nd e
mpt
y en
clos
ures
73
OEC Product Catalogue
Spare parts
Code
19000352 Spare door no padlock latch
19000262 Spare door with padlock latch
19000340 Spare door with padlock latch and window
12694810 Textured spare door National type
19000061 Top
Base plates
Code Material Width(mm)
Height(mm)
Thickness(mm)
N1ST0249 Steel 420 460 2
N1ST0250 Bakelite 420 460 4
N1ST0251 PVC 420 460 4
Accessories for installation
Code
S038410W Pole and wall mounting brackets (pag. 101)
S038430W Floor mounting frame (pag. 104)
N0ST0145 Base series ARE/BS “With mounting frame” (pag. 95)
Joining components
Code
S037540WConnection plate for base mounting (pag. 98)
S037531WCoupling plate for stacking two enclosures (pag. 99)
End plate
Code
15639941 Base panel in SMC with seal (pag. 96)
13640240 Base panel in Bakelite (pag. 96)
13639880 Base panel in perforated Bakelite (pag. 97)
Encl
osur
es a
nd e
mpt
y en
clos
ures
74
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/BENCLOSURE 600x600
Article Code: N0ST0140/1 (Enclosure for metering equipment with Lock SC/1)
N0ST0140/2 (Enclosure for terminal blocks with Lock SC/T) N0ST0140/3 (Enclosure for private customers with Lock SC/1 and blank logo)
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance 20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• See Enel Specification: DS 4549; nr.. Enel 284051for metering equipment;
nr. Enel 286030 for terminal block.
General characteristics:• Predisposition for the installation of: 1) Three integrated mono-phase me-
ters GMI-type- Y. 2) One three-phase meter GTI-type- Y. 3) Three electronic mono-phase meters GEM-type via B3M board. 4) Two electronic mono-phase meters GEM-type plus one electronic three-phase meter up to 15 KW GET-1 or GET-2A type via B3M board. 5) Three electronic three-phase meters up to 15 KW GET-1 or GET-2A-type via B3T board. 6) One elec-tronic three-phase meter up to 30 KW GET-3A o GET-3B type via Enel DS 4464/2 type board. 7) One terminal block MST/S-B150 series. 8) Other devices with appropriate base plate.
• Textured door with moulded hinge allowing a 120° opening. It is remova-ble to facilitate access.
• Three-point lock Enel-type DS 4541/1 with triangular or Yale type key Enel type triangular key on versions with terminal block.
• Internal ventilation obtained by means of a conduit between the cover and the sides.
• The enclosure is predisposed for floor mounting via Enel DS 4548 type base.
• Standard supply is with open base.
Accessories:• For further ACCESSORIES, specifications and spare parts relative to the
series ARE/B, see pag. 78.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 610 609 246
Internal dimensions 560 550 200
Code DescriptionN0ST0140/12 Enclosure blank logo with lock coding 12 N0ST0140/21 Enclosure blank logo with lock coding 21N0ST0140/NW Enclosure blank logo without lockN0ST0140/AW Enel, open top, without lock, with coupling plateN0ST0140/ANW Blank logo, open top, without lock, with coupling plate
ARE/B
610 246
609
Encl
osur
es a
nd e
mpt
y en
clos
ures
75
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/B-BSENCLOSURE 600x600 BASE MOUNTED
Article Code: N0ST0260
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance 20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• In compliance with Enel Specifications: DS 4549.
General characteristics:• Predisposition for the installation of: 1) Three integrated mono-phase meters GMI – Y type. 2) One three-pha-
se meter GTI – Y type. 3) Three electronic mono-phase meters GEM type via B3M board. 4) Two electronic mono-phase meters GEM type plus an electronic three-phase meter up to 15 KW GET-1 or GET-2A-type via B3M board. 5) Three electronic three-phase meters up to 15 KW GET-1 or GET-2A-type via B3T board. 6) One electronic three-phase meter up to 30 KW GET-3A o GET-3B-type via Enel board DS 4464/2-type. 7) One terminal block series MST/S-B150. 8) Other application via base plate.
• Textured door with moulded hinge allowing a 120° opening. It is remova-ble to facilitate access.
• Three-point lock Enel-type DS 4541/1 with triangular or Yale type key Enel type triangular key on versions with terminal block.
• Internal ventilation obtained by means of a conduit between the cover and the sides.
• The enclosure is predisposed for floor mounting via Enel base DS 4548-type and includes frame 1ST0192.
• Predisposition for the installation of Enel DS 4464/2 type board to mount the electronic three-phase boxes or Enel B3M DH 902-A7 base to mount 2 mono-phase electronic box and 1 three-phase box for terminal blocks and low voltage breakers.
Accessories:• For further ACCESSORIES, specifications and spare parts relative to the
series ARE/B-BS, see pag. 78.
Width (mm) Height (mm) Depth (mm)
Internal dimensions (Enclosure) 560 550 200
Internal dimensions (Base) 310-490 550 180
Overall dimensions(Enclosure + Base)
610 1190 246
Code DescriptionN0ST0260/12 Enclosure blank logo with lock coding 12
N0ST0260/21 Enclosure blank logo with lock coding 21
N0ST0260/NW Enclosure blank logo without lock
ARE/B-BS
610
1190
246
Encl
osur
es a
nd e
mpt
y en
clos
ures
76
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/B-SSENCLOSURE600x600 STACKED
Article Code: N0ST0190 (Two stacked enclosures) N0ST0191 (Three stacked enclosures)
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• See Enel Specification: DS 4549.
General characteristics:• Enclosure stacked on identical enclosure to double the available space.
Multiple versions are available for up to 3 or 4 stacked enclosures.• Textured door with moulded hinge allowing a 120° opening. It is remova-
ble to facilitate access.• Three-point lock Enel-type DS 4541/1 with triangular or Yale type key Enel
type triangular key on versions with terminal block.• Internal ventilation obtained by means of a conduit between the cover
and the sides.• The enclosure is predisposed for floor mounting via Enel base DS
4548-type.• The enclosures can be stacked up to three or four in order to obtain ma-
ximum space. The enclosure is also predisposed for the installation of the Enel board DS 4464/2 type for the electronic three-phase meter or the Enel B3M DH 902-A7 base for the installation of two electronic mono-phase meters and one three-phase meter and terminal blocks and low voltage breakers.
• Standard supply is with open bottom.
Accessories:• For further ACCESSORIES, specifications and spare parts relative to the
series ARE/BSS, see pag.78.
Width (mm) Height (mm) Depth (mm)
Overall dimensions double version 610 1210 246
Overall dimensions triple version 610 1814 246
Internal dimensions single enclosure 560 550 200
Code DescriptionN0ST0190/12 Double Enclosure blank logo with lock coding 12 N0ST0190/21 Double Enclosure blank logo with lock coding 21N0ST0190/NW Double Enclosure blank logo without lockN0ST0191/12 Triple Enclosure blank logo with lock coding 12N0ST0191/21 Triple Enclosure blank logo with lock coding 21
N0ST0191/NW Triple Enclosure blank logo without lock
ARE/B
N0ST0140/1-2-3
N0ST0140/1-2-3
610
1210
246
Encl
osur
es a
nd e
mpt
y en
clos
ures
77
OEC Product Catalogue
ARE/B
N0ST0140/1-2-3
N0ST0140/1-2-3
N0ST0140/1-2-3
610
1814
246
Encl
osur
es a
nd e
mpt
y en
clos
ures
78
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/BACCESSORIES for ENCLOSURE600x600
Accessories for racking equipment
Code
N1ST0219Bottom frame inclu-ding racking panels(see note)
• Mounting kit for racking equipment (See picture)
• N° 2 Perforated panels 538x149 mm (See picture)
• N°1 Blank panel 538x149 mm (See picture)• N° 1 Blank panel 538x 99 mm (See picture)
Note:For different uses it is possible to vary the composition of panels assembled on the mounting kit.
Racking equipment components
Code
N2SF0156 Blank panels 538 x149 mm• Panel• Mounting bracket kit
N2SF0160 Blank panel 538 x 99 mm• Panel• Mounting bracket kit
N2SF0158 Perforated panel 538 x149 mm• Mounting Kit for racking equipment
N1ST0365Bottom frame to mount racking equipment
• Left and right angle bars • Mounting Kit
N1ST0220 Inner door (see note) • Door• Mounting Kit
Locks, rods and hinges
Code
N0SF0010 Lock series SC/1 (pag. 159)
N0SF0011 Lock series SC/T (pag. 158)
S4541Y12 Lock with coding 12 series SC/12 (pag. 160)
S4541Y21 Lock with coding 21 series SC/21 (pag. 160)
PALETNAZ Adjustable rods kit
N1ST0649 Hinge
Note:the inner door cannot be assembled without respective frame and panels, cod. N1ST0219.
Encl
osur
es a
nd e
mpt
y en
clos
ures
79
OEC Product Catalogue
Spare parts
Code
N2ST0179 Textured spare door (with Enel logo)
N2ST0179/N Textured spare door (blank logo)
N2ST0177 Top
Base plates
Code MaterialWidth(mm)
Height(mm)
Thickness(mm)
N1ST0221 Steel 540 500 2
N1ST0240 Bakelite 540 500 4
N1ST0244 PVC 540 500 4
Accessories for Installation
Code
N1ST0194 Floor mounting frame (pag. 103)
N0ST0145 Base series ARE/BS “With mounting frame” (pag. 95)
Joining elements
Code
N2ST0213 Joining element for enclosures
Encl
osur
es a
nd e
mpt
y en
clos
ures
80
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/CENCLOSURE700x700
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI 500.• Impactresistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• In compliance with Enel Specifications: 282227 for Lombardy, 282220 for Tri-
veneto.
General characteristics:• Predisposition for the installation of: 1) Four integrated mono-phase meters GMI-type- Y. 2) Two three-phase me-
ters GTI-type- Y. 3) Four electronic mono-phase meters GEM-type via two Z2M boards with four T2A2 boards. 4) Two electronic three-phase meters up to 15 KW GET-1 or GET-2A-type via two Z2M boards with two T4A4 boards. 5) One electronic mono-phase meter GEM-type via Z1M board with T2A2, plus one electronic three-phase meter up to 15 KW GET-1 or GET-2A-type via Z2M board with T4A4. 6) Two electronic mono-phase meters GEM-type via Z2M board with two T2A2, plus one electronic three-phase meter up to 15 KW GET-1 or GET-2A type via Z2M board with T4A4. 7) One electronic three-phase meter up to 30 KW GET-3A or GET-3B type via Enel DS 4464/2 type board. 8) One terminal block series MST/S-B150. 9) Other application via base plate.
• Smooth door, hinged with a 90° opening which is removable for easier access. • Three-point lock. The lock can be supplied with a triangular key, a cross key ,
Yale-type or National upon request.• Ventilation obtained via conduit between the cover and the sides.• Fit for wall mounting, pole mounting with bracket, floor mounting with frame
or base mounting with plate.• Available with closed bottom with 5 cable holes or fully open base.
Accessories:• For further ACCESSORIES, specifications and spare parts relative to the series
ARE/C, see pag. 83.
Width (mm) Height (mm) Depth (mm)Overall dimensions 714 660 271Internal dimensions 685 640 235
Code Description Tab. ENELS03743GW Lock with triangular key and padlock latch Enel Lombardy 2822 DS03743YK With lock coding 12 -S03743YW With lock coding 21 -S03743NZ With lock series SC/1 -S03743SK Without lock -S03743ST Senza tetto, senza serratura e con piastra accoppiamento
S03746GW Open top, without lock with coupling plate S03746GW Lock with triangular key and padlock latch Enel Lombardy (open bottom) 2822 D
S03746YK With lock coding 12 (open bottom) -S03746YW With lock coding 21 (open bottom) -S03746NZ With lock series SC/1 (open bottom) -S03746SK Without lock (open bottom) -S03746ST Open top, without lock with coupling plate (open bottom) -
714
66
0
271
ARE/C
Encl
osur
es a
nd e
mpt
y en
clos
ures
81
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/C-BSENCLOSURE700x700 BASE MOUNTED
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI 500.• Impact resistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• In compliance with Enel Specifications: 282227 for Lombardy, 282220 for
Triveneto.
General characteristics:• Predisposition for the installation of: 1) Four integrated mono-phase meters GMI-type- Y. 2) Two three-phase
meters GTI – Y type. 3) Four electronic mono-phase meters GEM-type via Z2M with four T2A2 boards. 4) Two electronic three-phase meters up to 15 KW GET-1 or GET-2A-type via two Z2M boards with two T4A4. 5) One elec-tronic mono-phase meter GEM-type via Z1M board with T2A2, plus one electronic three-phase meter up to 15 KW GET-1 or GET-2A type via Z2M board With T4A4. 6) Two electronic mono-phase meters GEM-type via Z2M board with two T2A2, plus one electronic three-phase meter up to 15 KW GET-1 or GET-2A type via Z2M board with T4A4. 7) One electronic three-phase meter up to 30 KW GET-3A or GET-3B-type via board Enel DS 4464/2 type board. 8) One terminal block series MST/S-B150. 9) Other application via base plate.
• Smooth door, hinged with a 90° opening which is removable for easier access.
• Three point lock. The lock can be supplied with a triangular key, a cross key, Yale-type or National upon request.
• Ventilation obtained via conduit between the cover and the sides.• The enclosure is predisposed for floor mounting via Enel base DS 4548-type
and includes frame N1ST0192.
Accessories:• For further ACCESSORIES, specifications and spare parts relative to the series
ARE/C-BS, see pag.83.
Code Description
SB3743GW Lock with triangular key and padlock latch Enel LombardySB37433W With lock coding 12SB37432W With lock coding 21SB3743NZ With lock SC/1SB3743SK Without lock
Width (mm) Height (mm) Depth (mm)
Internal dimensions (Enclosure) 685 640 235
Internal dimensions (Base) 310-490 550 180
Overall dimensions(Enclosure + Base)
714 1200 271
271714
1200
ARE/C-BS
Encl
osur
es a
nd e
mpt
y en
clos
ures
82
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/C-SSENCLOSURE 700x700 STACKED
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI 500.• Impactresistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• In compliance with Enel Specifications: 282227 for Lombardy, 282220 for
Triveneto.
General characteristics:• Enclosure stacked on identical enclosure to double the available space.
Multiple versions are available for up to 3 or 4 stacked enclosures. • Smooth door, hinged with a 90° opening which is removable for easier
access.• Three-point lock. The lock can be supplied with a triangular key, a cross key,
Yale-type or National upon request.• Ventilation obtained via conduit between the cover and the sides.• Predisposition for floor mounting with corresponding frame see Acces-
sories.• Standard supply is with open bottom.
Accessories:• For further accessories, specifications and spare parts relative to the series
ARE/C-SS, see pag. 83.
Code Description
S03743SW With triangle locks and padlock latch upper and lower
SY57452K With lock coding 12 upper and lower
SY57450K With lock coding 12 upper and lower
SY57451K With lock coding 21 upper and lower
S03743NW With lock SC/1 upper and lower
S03743SS Without lock
Width (mm) Height (mm) Depth (mm)
Overall dimensions 714 1284 271
Internal dimensions(Single enclosure) 685 640 235
ARE/C-SS
Encl
osur
es a
nd e
mpt
y en
clos
ures
83
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/CACCESSORIES for ENCLOSURE 700x700
Accessories for racking equipment
Code
N1ST0259
Bottom frame including modular racking panels(see note)
• Mounting kit for racking equip-ment (See picture)
• N° 2 Perforated panels 538x149 mm (See picture)• N°1 Blank panel 538x149 mm (See picture)• Frame
Note:It is possible to vary the composition of panels assembled on the mounting kit.
Racking equipment components
Code
N2SF0156 Blank panel 538x149 mm• Panel• Mounting bracket kit
N2SF0158 Open panel 538x149 mm• Mounting kit for racking equipment
N1ST0368Bottom frame to mount racking equipment
• Right and left angle bars • Mounting kit
N1ST0372 Inner door (see note) • Door• Mounting kit
Locks, poles and hinges
Code
19000454 Lock series SC/T2 (pag. 162)
19000644 Lock series SC/T1L (pag. 163)
See table Lock series SC/SL (pag. 165)
See table Lock series SC/YL (pag. 164)
N0SF0010 Lock series SC/1 (pag. 159)
N0SF0011 Lock series SC/T (pag. 158)
S4541Y12 Lock with coding 12 series SC/12 (pag. 160)
S4541Y21 Lock with coding 21 series SC/21 (pag. 160)
PALET700 Enclosure pole kit 700x700
PALETNAZ Enclosure pole kit 700x700 with National door
N1ST0649 Hinge
Note:the inner door cannot be assembled without respective frame and panels, cod. N1ST0259.
Encl
osur
es a
nd e
mpt
y en
clos
ures
84
OEC Product Catalogue
Spare parts
Code
19000739 Spare door
19000756 Spare door National type
19000740 Cover
Base plates
Code Material Width(mm)Height(mm)
Thickness(mm)
N1ST0255 Steel 569 613 2
N1ST0256 Bakelite 569 613 4
N1ST0257 PVC 569 613 4
Accessories for installation
Code
S038440W Pole and wall mounting bracket (pag. 102)
S038430W Floor mounting frame (pag. 104)
N0ST0145 Base series ARE/BS “With mounting frame” (pag. 95)
Connection components
Code
S037543WCoupling plate for stacking enclosures(pag. 100)
Base plate
Code
19000619 SMC base plate (pag. 97)
S284523K Perforated SMC base plate forato (pag. 98)
Encl
osur
es a
nd e
mpt
y en
clos
ures
85
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/DENCLOSURE 500x900
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI
500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accor-
dance with CEI EN 62262.• In compliance with Enel Specifications: 282218 for Lombardy
General characteristics:• Ideal for installing control or measurement devices or cabled instruments
of different nature. They can be mounted via the base plate. It is often used on construction sites for temporary connections.
• Smooth door, hinged with a 90° opening which is removable for easier access.
• Three-point lock with padlock latch. The lock can be supplied with a trian-gular key, a cross key or Yale-type upon request.
• Ventilation obtained via conduit between the cover and the sides.• Fit for wall mounting, pole mounting with bracket, floor mounting with
frame or base mounting with plate. (see Accessories).• the bottom side of the enclosure is made of two semi-panels with three
rubber-sealed holes for cable passage and protection.• Standard unit is supplied with a closed base and predisposition for cable
passage holes (except for the version without a cover which has an open base).
Accessories:• For further accessories, specifications and spare parts relative to the series
ARE/D, see pag. 89.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 540 900 305
Internal dimensions 515 880 255
Code DescriptionTableENEL
S03740GW With triangular-key lock and padlock latch Enel Lombardy MZ 019
SL3740GW With padlock latch only -
S62751YK With lock coding 12 -
S62750YK With lock coding 21 -
S03740SK Without lock -
S03740ST Open top, without lock, with coupling plate -
900
540 305
ARE/D
Encl
osur
es a
nd e
mpt
y en
clos
ures
86
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/D-BSENCLOSURE 500x900 BASE MOUNTED
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI
500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accor-
dance with CEI EN 62262.• In compliance with Enel Specifications: 282218 for Lombardy.
General characteristics:• Ideal for installing control or measurement devices or cabled instruments
of different nature. They can be mounted via the base plate. It is often used on construction sites for temporary connections.
• Smooth door, hinged with a 90° opening which is removable for easier access.
• Three-point lock with padlock latch. The lock can be supplied with a trian-gular key, a cross key or Yale- one upon request.
• Ventilation obtained via conduit between the cover and the sides.• The enclosure is predisposed for floor mounting via Enel DS 4548-type
base and includes frame N1ST0192.
Accessories:• For further accessories, specifications and spare parts relative to the series
ARE/D, see pag. 89.
Code DescriptionBoardENEL
S04740GWWith triangular key lock and padlock latchEnel Lombardy
-
SL4740GW With padlock latch only -
S4740Y12 With lock coding 12 -
S4740Y21 With lock coding 21 -
S04740SK Without lock -
Width (mm) Height (mm) Depth (mm)
Internal dimensions (Enclosure) 515 880 255
Internal dimensions (Base) 310-490 550 180
Overall dimensions(Enclosure + Base) 540 1480 305
1480
540 305
ARE/D-BS
Encl
osur
es a
nd e
mpt
y en
clos
ures
87
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/D-SSENCLOSURE 500x900 STACKED
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI
500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accor-
dance with CEI EN 62262.• In compliance with Enel Specifications: 282218 for Lombardy.
General characteristics:• It is made up of two stacked enclosures to maximise space.• Smooth door, hinged with a 90° opening which is removable for easier
access. • Three-point lock with padlock latch. The lock can be supplied with a trian-
gular key, a cross key or Yale-type upon request.• Ventilation obtained via conduit between the cover and the sides.• Predisposition for floor mounting by frame• Standard supply is with open bottom.
Accessories:• For further accessories, specifications and spare parts relative to the series
ARE/D, see pag.89.
Code Description
S05740GW With triangular lock and padlock latch upper and lower
SL5740GW With padlock latch only upper and lower
S5740Y12 With lock coding 12 upper and lower
SY57430K With lock coding 12 upper and lower
S5740Y21 With lock coding 21 upper and lower
S05740SS Without lock
Width (mm) Height (mm) Depth (mm)
Overall dimensions 540 1783 305
Internal dimensions(Single enclosure) 515 880 255
540 305
1783
ARE/D-SS
Encl
osur
es a
nd e
mpt
y en
clos
ures
88
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/A-D-SSENCLOSURE 500x900 plus 500x500 STACKED
Article Code: See Table
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI
500.• Protection level: IP 43 in accordance with CEI EN 60529 - IK 10 in accor-
dance with CEI EN 62262.
General characteristics:• It is made up of two stacked enclosures to maximise space.• Smooth door, hinged with a 90° opening which is removable for easier
access. • Three-point lock with padlock latch. The lock can be supplied with a trian-
gular key, a cross key or Yale-type upon request.• Ventilation obtained via conduit between the cover and the sides.• Predisposition for floor mounting by frame• Standard supply is with open bottom.
Accessories:• For further accessories, specifications and spare parts relative to the series
ARE/A-D-SS, see pag. 89.
Code Description
S05743GW With triangular lock and padlock latch upper and lower
SL5743GW With padlock latch only upper and lower
S5743Y12 With lock coding 12 upper and lower
S57430GK With lock coding 12 upper and lower
S5743Y21 With lock coding 21 upper and lower
S05743SS Without lock
Width (mm) Height (mm) Depth (mm)
500x900 Internal dimensions 515 880 255
500x500 Internal dimensions 515 520 255
Overall dimensions(Stacked enclosures) 540 1433 305
540 305
1433
ARE/A-D-SS
Encl
osur
es a
nd e
mpt
y en
clos
ures
89
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/DACCESSORIES for ENCLOSURE 500x900
Accessories for racking equipment
Code
N1ST0245
Bottom frame including modular racking panels(See note)
• Mounting kit for racking equipment (See picture)
• N° 3 Perforated panels 466x149 mm (See picture)
• N°2 Blank panels 466x149 mm (See picture)
Note:It is possible to vary the composition of panels assembles on the mounting kit.
Racking equipment components
Code
N2SF0155 Blank panel 466x149 mm• Panel• Mounting bracket kit
N2SF0157 Open panel 466x149 mm• Racking equipment mounting kit
N1ST0367Bottom frame to mount racking equipment
• Left and right angle bars• Mounting kit
N1ST0369 Inner door (See note) • Door• Mounting kit
Locks, poles and hinges
Code
19000454 Lock series SC/T2 (pag. 162)
19000644 Lock series SC/T1L (pag. 163)
See Table Locks series SC/SL (pag. 165)
See Table Locks series SC/YL (pag. 164)
S63790AW Locks series SC/ML with padlock latch only (pag. 161)
PALET900 Enclosure poles kit 500x900
19000133 Hinge mounting plate
19000134 Hinge
15627590 Hinge pin
Note:The inner door cannot be assembled without respective frame and panels cod. N1ST0259.
Encl
osur
es a
nd e
mpt
y en
clos
ures
90
OEC Product Catalogue
Spare parts
Code
19000278 Spare door with no padlock latch
19000270 Spare door with padlock latch
19000061 Top
Base plates
Code MaterialWidth(mm)
Height(mm)
Thickness(mm)
N1ST0252 Steel 468 778 2
N1ST0253 Bakelite 468 778 4
N1ST0254 PVC 468 778 4
Accessories for installation
Code
S038400W Pole and wall mounting bracket (pag. 102)
S038430W Floor mounting frame (pag. 104)
N0ST0145 Base series ARE/BS “With mounting frame” (pag. 95)
Connection components
Code
S037540W Connection plate to stack two enclosures (pag. 98)
S037531WCoupling plate to stack two enclosures (pag. 99)
End plate
Code
15639941 SMC end plate with seal (pag. 96)
13640240 Bakelite end plate (pag. 96)
13639880 Perforated Bakelite end plate (pag. 97)
Encl
osur
es a
nd e
mpt
y en
clos
ures
91
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/EENCLOSURE for METERING EQUIPMENT GTWS-type from 30kV to 200kVArticle Code: N0ST0299
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI 500.• Impactresistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• Nominal applied voltage: 400 V.• Nominal Earth Voltage: 400 V.• See Enel Specification: DS 4558 (National) nr. Enel 284092.
General characteristics:• Predisposition for the installation of integrated GTWS equipment including
Current Transformer board, DY 4451 and DY 4471. For all other applications it is possible to use the rear plate.
• The enclosure includes a hinged textured door with a 90° opening which is removable for easier access; an Enel type lock 4541 (Italian national stan-dards) allowing independent inspection by multiple users; and a raised base to facilitate accessibility.
• It must be floor mounted with the anchorage frame N1ST0560 included.• It is possible to personalise the colour and add trademarks upon request.
Accessories:• N2ST0303 - Spare door.• N2ST0305 - Top.• N0SF0010 - Lock series SC/1 (pag. 159).• N0SF0011 - Lock series SC/T (pag. 158).• S4541Y12 - Lock with coding 12 series SC/12 (pag. 160).• S4541Y21 - Lock with coding 21 series SC/21 (pag. 160).• PALETGTW - Pole kit.• N1ST0648 - Hinge • N1ST0560 - Floor mounting frame (pag. 105).• N0ST0308 - Bakelite Plate (5 mm thick) 1014x544 mm.• N0ST0321 - Steel Plate (2 mm thick) 1014x544 mm.• N0ST0322 - PVC Plate (5 mm thick) 1014x544 mm.• N0ST0262 - Ventilation louver (Protection level variation IP 54).• N8ST0333 - Axial fan (pag.61).• N0ST0195 - Door to access the racking equipment space.• N0CE0021 - Low Voltage CT assembly (nr.530014).
Width (mm) Height (mm) Depth (mm)
Overall dimensions 650 1560 350
Internal dimensions 640 1020 280
Mounting points 605 238
Code DescriptionN0ST0299/12 Enclosure blank logo with lock coding 12N0ST0299/21 Enclosure blank logo with lock coding 21N0ST0299/N Enclosure blank logo
ARE/E
651 352±2
1560
±3
605±2
238±
2
Encl
osur
es a
nd e
mpt
y en
clos
ures
92
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/CBTENCLOSURE for the INSTALLATION of CONCENTRATOR TERMINALS on TRANSFORMATION SITE on POLES (P.T.P)
Article Code: N0ST0131 (ENEL with Lock SC/T-type) N0ST0131/N (blank logo with Lock SC/1-type)
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• See Enel Specification: DH 2480 (National). nr. 288041.
General characteristics:• Predisposition for wall or pole mounting of enclosure for Enel B-CBT type
platform for low voltage concentrator terminals. • Textured door with 120° opening and possibility of removal for easier
access.• Internal ventilation obtained by 3000 mm2 vents located on the enclosure
sides, able to disperse approx. 25 W internal energy. The vents can be fitted with fans to force air circulation. The Vents include insect mesh.
• The bottom of the enclosure contains two holes for power and cables of which one is open for PG36-type connection suitable for 40 mm corru-gated sheath, while the other is plugged for a PG 21-type connection suitable for 25 mm corrugated sheath.
• The lock is a three-point Enel 4541 type (Italian national standards), se-ries SC/T.
Accessories:• N2ST0165 - Textured spare door (with Enel logo).• N2ST0165P - Textured spare door (blank logo).• N0SF0010 - Lock series SC/1 (pag. 159).• N0SF0011 - Lock series SC/T (pag. 158).• S4541Y12 - Lock with coding 12 series SC/12 (pag. 160).• S4541Y21 - Lock with coding 21 series SC/21 (pag. 160).• PALETNAZ - Pole kit.• N1ST0180 - Hinge.• N1ST0536 - Steel base plate 2 mm-thick.• N1ST0262 - Full ventilation louver.• N8ST0333 - Axial fan (pag.61).
Width (mm) Height (mm) Depth (mm)
Overall dimensions 465 615 265
Internal dimensions 415 570 205
ARE/CBT
465
615
487
265
Encl
osur
es a
nd e
mpt
y en
clos
ures
93
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/PTP-1 ENCLOSURE for LOW VOLTAGE BREAKERS on TRANSFORMATION SITE on POLES (P.T.P)
Article Code: N0ST0126 (ENEL with SC/T-type Lock) N0ST0126/N (neutral with SC/1-type Lock)
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• In compliance with Specification: Enel DY 3023 (National).
General characteristics:• Suitable for pole mounting for the installation of a four pole breaker Enel
DY 3101 type. • The bottom of the enclosure contains knockout hole tabs for the installa-
tion of revolving fitting for spiral conduits.• Textured door, hinged with 120° opening which is removable for easier
access. • Internal ventilation obtained by means of a conduit along the door peri-
meter • The lock is Enel type 4541 (Italian national standards) with triangular key,
series SC/T.• It is possible to personalise the colour and add trademarks upon request.
Accessories:• 12690520 - Textured spare door (with Enel logo).• 12690521 - Textured spare door (blank logo).• N0SF0010 - Lock series SC/1 (pag. 159).• N0SF0011 - Lock series SC/T (pag. 158).• S4541Y12 - Lock with coding 12 series SC/12 (pag. 160).• S4541Y21 - Lock with coding 21 series SC/21 (pag. 160).• PALETNAZ - Pole kit.• 16690560 - Internal hinge.• 16690570 - External hinge.• 15690550 - Hinge pin.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 285 600 315
Internal dimensions 205 545 230
ARE/PTP-1
Encl
osur
es a
nd e
mpt
y en
clos
ures
94
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/PTP-2 ENCLOSURE for 2 LOW VOLTAGE BREAKERS on TRANSFORMATION SITE on POLES (P.T.P)
Article Code: S228040K (ENEL with SC/T-type lock) S228040K/N (blank logo with SC/1-type lock)
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• In compliance with regulations CEI EN 60439-5 (/A1).• In compliance with DS4931 in accordance with Enel specifications.• Fire resistance in accordance with Enel Specifications DS 4974: >80 Points.• Surface draught resistance in accordance with regulations IEC 60112: PTI
500.• Impact resistance20J in accordance with CEI EN 60439/5.• Protection level: IP 34 D in accordance with CEI EN 60529.• In compliance with Enel Specifications: DY 3018 (National).
General characteristics:• Suitable for pole mounting for the installation of a four pole breaker Enel
DY 3101 type including two holes on the back of the enclosure and one on the bottom with tap and lock washer for cable passage.
• Textured door with stainless steel hinges which is removable for easier access.
• Internal ventilation obtained by means of a conduit along the door peri-meter
• The lock is Enel-type 4541 (Italian national standards) allowing indepen-dent inspection by multiple users. Alternatively it is possible to assemble a personalised cross key lock.
Accessories:• 19000630 - Spare door Enel logo.• 19000760 - Spare door blank logo.• N0SF0010 - Lock series SC/1 (pag. 159).• N0SF0011 - Lock series SC/T (pag. 158).• S4541Y12 - Lock with coding 12 series SC/12 (pag. 160).• S4541Y21 - Lock with coding 21 series SC/21 (pag. 160).• PALETNAZ - Pole kit.• 15655100 - Internal hinge.• 15690170 - External hinge.• 15655120 - Hinge pin.
Width (mm) Height (mm) Depth (mm)
Overall dimensions 450 615 265
Internal dimensions 420 568 155 470
615
265
ARE/PTP-2
Encl
osur
es a
nd e
mpt
y en
clos
ures
95
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSerieS ARE/BSSYNTHETIC RESIN MONOLITHIC BASE for ENCLOSURES
Article Code: N0ST0145
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: 80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI
500.• Protection level: IP 44 in accordance with CEI EN 60529 - IK 10 in accor-
dance with CEI EN 62262.• See Enel Specification: DS 4548 (National) Nr. 286041 With frame.
General characteristics:• The base contains two plugged holes for eventual cable passage.• Stainless-steel bolts and nuts.• Frame included N1ST0192.
The base fits:• Enclosures for external use ARE/A (pag. 69).• Enclosure for external use ARE/B (pag. 74).• Enclosure for external use ARE/C (pag. 80).• Enclosure for external use ARE/D (pag. 85).• S037540W – Adaption plate to fit enclosures ARE/A and ARE/D onto the
base (pag. 98).
Width (mm) Height (mm) Depth (mm)
Overall dimensions 400/696 550 198
Internal dimensions 310-490 550 180696
550
400 198
ARE/BS
Encl
osur
es a
nd e
mpt
y en
clos
ures
96
OEC Product Catalogue
Fibreglass enclosures for metering equipmentSeries ARE/A-C-DACCESSORIES
General characteristics:• Designed for assembly on enclosures for C3M (500x500) or 500x900 type
meters to allow complete closure.• The end plate is press-fit to the enclosure.
Code Accessories per series:Dimensions
Width (mm)
Height(mm)
Thickness(mm)
15639941
ARE/A ARE/D ARE/A-SSARE/A-D-SS ARE/D-SS
475 265 5
Technical characteristics:• Suitable for C3M 500x500 and 500x900 type meters for the passage of
cables and adequate closure. • The end plate is made up of two parts that snap-fit to the enclosure.• On the connection axis there are three diameter 60/30/60 mm rubber sea-
led holes, to facilitate the passage and protection of the cables. The rubber is fixed to the bottom by copper pop rivets.
BASE COVER PLATE in SMC with SEAL
General characteristics:• Designed to be assembled on C3M 500x500 and 500x900 type meters
for the passage of cables and adequate closure. The end plate is press-fit to the enclosure. It includes two holes suitable for the passage of PG 29-type cable ducts.
Code Accessories per series:Dimensions
Width (mm)
Height(mm)
Thickness(mm)
13640240
ARE/A ARE/D ARE/A-SSARE/A-D-SS ARE/D-SS
476 265 4
Technical characteristics:• Bakelite derived from pure cellulose paper and phenolic resin with eleva-
ted mechanical characteristics.
BASE COVER PLATE in BAKELITE
Encl
osur
es a
nd e
mpt
y en
clos
ures
97
OEC Product Catalogue
General characteristics:• The connection plate is fixed to the C3M(500x500) o 500x900 Enclosure
by means of four holes and M8 screws, and to the floor by means of the four embedded inserts also with M8 screws.
• On the plate there are also two sealed 35 mm holes closed for the passa-ge of cables.
Code Accessories per seriesDimensions
Width (mm)
Height(mm)
Thickness(mm)
13639880
ARE/AARE/DARE/A-SSARE/A-D-SS ARE/D-SS
476 265 4
BASE PLATE in PERFORATED BAKELITE
BASE PLATE in SMC
Code Accessories per seriesDimensions
Width (mm)
Height(mm)
Thickness(mm)
19000619ARE/C ARE/C-SS
698 200 14
General characteristics:• Designed to be assembled on C4M (700x700) type meters for complete
closure. • The end plate is fixed to the Enclosure by four M8 zinc-coated screws. The
bottom is supplied completely closed but with seven knockout hole tabs
Technical characteristics:• Bakelite derived from pure cellulose paper and phenolic resin with high
mechanical properties.
Technical characteristics:• SMC (Vetroresina) colore grigio RAL 7001.• Resistenza alla fiamma, secondo Prescrizioni Enel DS 4974: 80 Punti.• Resistenza alle correnti superficiali secondo norme IEC 60112 - PTI 500.
Encl
osur
es a
nd e
mpt
y en
clos
ures
98
OEC Product Catalogue
General characteristics:• The connection plate is fixed to the C3M(500x500) o 500x900 Enclosure
by means of four holes and M8 screws, and to the floor by means of the four embedded inserts also with M8 screws.
• On the plate there are also two sealed 35 mm holes closed for the passage of cables.
Code Accessories per seriesDimensions
Width (mm)
Height(mm)
Thickness(mm)
S037540WARE/A-BS ARE/D-BS
530 285 26
Effective dimensions for cable passage
Width (mm)
Height(mm)
Thickness(mm)
330 160 5
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: 80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI 500.
CONNECTION PLATE
Code Accessories per seriesDimensions
Width (mm)
Height(mm)
Thickness(mm)
S284523KARE/C ARE/C-SS
698 200 14
General characteristics:• Designed for the closure of enclosures for C4M (700x700) type meters.• The end plate is fixed to the Enclosure by means of four zinc-coated M8
screws. On the bottom there are two 45 mm holes for cable passage. There are also five other knockout hole tabs.
PERFORATED SMC END PLATE
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: 80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI 500.
Encl
osur
es a
nd e
mpt
y en
clos
ures
99
OEC Product Catalogue
Code Accessories per seriesDimensions
Width (mm)
Height(mm)
Thickness(mm)
S037531WARE/A-SS ARE/A-D-SS ARE/D-SS
535 302 35
Effective dimensions for cable passage
Width (mm)
Height(mm)
Thickness(mm)
260/360 75/120 13
CONNECTION PLATE
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: 80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI 500.
General characteristics:• The adaption plate is designed to combine the C3M (500x500) type and
the 500x900 type enclosures and has predisposition for cable passage. • The plate is fixed to the 500x500-type Enclosure by means of four holes
and M8 screws and to the 500x900-type Enclosure by means of the four embedded inserts on the plate also with M8 screws.
CONNECTION PLATE
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: 80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI 500.
General characteristics:• The connection plate is made to combine 2 or more C3M (600x600) type
enclosures.• The connection plate is fixed to the 600x600 type by means of four holes
and M6 screws
Code Accessories per seriesDimensions
Width (mm)
Height(mm)
Thickness(mm)
N2ST0213 ARE/B-SS
660 220 33
Effective dimensions for cable passage
Width (mm)
Height(mm)
Thickness(mm)
310 140 10
Encl
osur
es a
nd e
mpt
y en
clos
ures
100
OEC Product Catalogue
COUPLING PLATE
Technical characteristics:• SMC (Fibreglass) Grey colour RAL 7001.• Fire resistance in accordance with Enel Specifications DS 4974: 80 Points.• Surface draught resistance in accordance with regulations IEC 60112 - PTI 500.
General characteristics:• The connection plate is designed to combine two or more C4M (700x700)
type enclosures.• The connection plate is fixed to the 700x700 type by means of four holes
and M8 screws.
Code Accessories per seriesDimensions
Width (mm)
Height(mm)
Thickness(mm)
S037543W ARE/C-SS
725 220 55
Effective dimensions for cable passage
Width (mm)
Height(mm)
Thickness(mm)
595 145 55
Technical characteristics:• Steel Fe 360 B in accordance with UNI EN 10025 del 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
N0ST0207 ARE/C1M 170 260 17
POLE MOUNTING BRACKET
General characteristics:• Designed for assembly on enclosures GMI-Y and GTI-Y type for pole
mounting.• See ENEL Specification DS 4557 National.• The bracket is fixed to the Enclosure with three stainless-steel M8 Allen
head screws, and fixed to the pole by means of stainless-steel strap.
Encl
osur
es a
nd e
mpt
y en
clos
ures
101
OEC Product Catalogue
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
S038420W ARE/C1M 170 260 17
General characteristics:• Designed for assembly on C1M (500x200) type enclosures for pole
mounting. • The bracket is fixed to the Enclosure with two zinc-coated steel slotted head
screws and fixed to the pole via stainless steel strap.
POLE MOUNTING BRACKET
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
S038410W ARE/A 440 450 16
General characteristics:• Designed for assembly on C3M (500x500) type enclosure for meters for
pole mounting.• The bracket is fixed to the Enclosure with two zinc-coated steel M8 hexago-
nal screws and to the pole via stainless steel strap.
POLE AND WALL MOUNTING BRACKET
Technical characteristics:• Fe 360 B steel in accordance with UNI EN 10025 of 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
Technical characteristics:• Fe 360 B steel in accordance with UNI EN 10025 of 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
Encl
osur
es a
nd e
mpt
y en
clos
ures
102
OEC Product Catalogue
General characteristics:• Designed for assembly on C4M (700x700) type enclosure for pole
mounting.• The bracket with 69182/00 design is fixed to the pole by stainless steel strap.• The bracket with 69183/00 design is fixed to the Enclosure with two M8 zinc
coated steel slotted head screws, the enclosure is then connected to the pole bracket and fixed to the bottom with two M8 hexagonal screws.
POLE AND WALL MOUNTING BRACKET
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
S039440W ARE/C
575 500 40
Overall dimensions (69183/00)
Width (mm) Length (mm) Height (mm)
25 220 4
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
S038400W ARE/D 460 840 20
General characteristics:• The bracket can be assembled on Enclosure series ARE/D for pole and wall
mounting. • The bracket is fixed to the Enclosure with two M8 zinc-coated steel slotted
head screws and then fixed to the pole via stainless steel strap.
POLE AND WALL MOUNTING BRACKET
Technical characteristics:• Steel Fe 360 B in accordance with UNI EN 10025 del 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
Technical characteristics:• Fe 360 B steel in accordance with UNI EN 10025 of 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
Encl
osur
es a
nd e
mpt
y en
clos
ures
103
OEC Product Catalogue
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
N1ST0194 ARE/B ARE/B-SS 210 600 178*
General characteristics:• The frame can be assembled to C3M (600x600) type meter enclosures for
floor mounting. • The frame is fixed to the Enclosure with four zinc-coated steel M6 hexago-
nal screws.
FLOOR MOUNTING FRAME
*Height including brackets
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
N1ST0192
ARE/A-BS ARE/B-BS ARE/C-BS ARE/D-BS ARE/BS
200 695 190*
General characteristics:• The frame can be assembled to C3M (600x600) type meter enclosures for
floor mounting. • The frame is fixed to the Enclosure with four zinc-coated steel M6 hexa-
gonal screws.
FLOOR MOUNTING FRAME
*Height including brackets
Technical characteristics:• Fe 360 B steel in accordance with UNI EN 10025 of 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
Technical characteristics:• Steel Fe 360 B in accordance with UNI EN 10025 del 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
Encl
osur
es a
nd e
mpt
y en
clos
ures
104
OEC Product Catalogue
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
S039430WARE/C ARE/C-SS
200 695 190*
General characteristics:• The frame can be assembled on C4M type meter enclosures for floor
mounting.• The frame is mounted to the Enclosure with M8 zinc-coated steel hexagonal
screws.
FLOOR MOUNTING FRAME
*Height including brackets.
Technical characteristics:• Steel Fe 360 B in accordance with UNI EN 10025 of 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
S038430W
ARE/A ARE/D ARE/A-SS ARE/D-SS ARE/A-D-SS
275 520 85*
General characteristics:• The frame can be assembled on C3M (500x500) type meter enclosures for
floor mounting.• Frame mounting to the Enclosure is with four M8 zinc-coated steel hexa-
gonal screws.
FLOOR MOUNTING FRAME
*Height including brackets.
Technical characteristics:• Steel Fe 360 B in accordance with UNI EN 10025 del 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
Encl
osur
es a
nd e
mpt
y en
clos
ures
105
OEC Product Catalogue
CodeAccessories per series
Dimensions
Width (mm) Length (mm) Height (mm)
N1ST0560 ARE/E 300 625 140
FLOOR MOUNTING FRAME
General characteristics:• The frame can be assembled on GTWS (ARE/E)-type enclosures for meters
for floor mounting.• The frame is mounted to the Enclosure with four M8 zinc-coated steel he-
xagonal screws.
Technical characteristics:• Steel Fe 360 B in accordance with UNI EN 10025 of 1990.• Hot zinc-coated in accordance with standard CEI 7-6.
*Height including brackets.
OEC Product Catalogue