PRO-TEC SENTRY BUILDING
70' WIDTH
END WALL MANUAL
IMPORTANT - TO THE DEALER OR ERECTOR:
RETURN THIS MANUAL TO THE OWNER FOR THEIR FUTURE REFERENCE
SIOUX STEEL COMPANY, P.O. BOX 1265, SIOUX FALLS, SOUTH DAKOTA 571011-800-557-4689
MANUAL NO. 193884REV C/MRS 8/1/17 ECN 17-141
Dear Sentry Building Owner, We would like to take this opportunity to thank you for purchasing a SIOUX STEEL PRO-TEC BUILDING . We believe that it will serve you well for many years. The framework uses quality certified structural grade steel tubing. All welded rafter assemblies are powder coated or hot-dipped galvanized to provide maximum corrosion protection. We believe in providing QUALITY, RELIABILITY, DURABILITY, VERSATILITY , and COMMITMENT to meet the needs of our customer. Should you have any questions or comments during or following the installation, please feel free to call your SIOUX STEEL PRO-TEC BUILDING dealer or manufacturer. We will be glad to assist you in any way we can.
IMPORTANT Improper Site Preparation, Assembly and Maintenance may invalidate warranty and cause unnecessary and costly mistakes.
READ MANUAL FIRST
If you have any questions contact Sioux Steel Co. at 1-800-557-4689
Procedure For Viewing Sentry Manuals On-Line: • Log on to siouxsteel.com.
• Select Dealer Login in upper right hand corner.
• Enter Username, Password and select Submit.
If you don’t have a username and password, contact your dealer or
Sioux Steel Company Customer Service at 1-800-557-4689.
• Select the Engineering Manuals folder in the center of the screen.
• Select the ProTec Manuals folder.
• Select the Sentry folder.
• Based on manual description select the desired manual you wish to open, view
and/or print.
• A second tab will open up with a PDF file of the desired manual.
• If you wish to print the manual, select the printer icon in the upper left hand
corner.
TABLE OF CONTENTS
SAFETY PAGE 3
COMPONENTS PAGE 4-5
END WALL PARTS LIST PAGE 6-9
TOOLS & EQUIPMENT PAGE 10
INSTALLATION INSTRUCTIONS PAGE 11-13
PW LEG SOLID END WALL PAGE 14
PW LEG 18' DOOR END WALL PAGE 15
PW LEG 2-16' DOORS END WALL PAGE 16
6FT LEG SOLID END WALL PAGE 17
6FT LEG 18' DOOR END WALL PAGE 18
6FT LEG 2-16' DOORS END WALL PAGE 19
8FT LEG SOLID END WALL PAGE 20
8FT LEG 18' DOOR END WALL PAGE 21
8FT LEG 2-16' DOORS END WALL PAGE 22
10FT LEG SOLID END WALL PAGE 23
10FT LEG 18' DOOR END WALL PAGE 24
10FT LEG 2-16' DOORS END WALL PAGE 25
MAINTENANCE SCHEDULE PAGE 26-27
WARRANTY STATEMENTS PAGE 28
2
SAFETY
Watch for this symbol. It points out important safety precautions. It means “Attention – Be Alert!”
DEFINITIONS:CAUTION: Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.
WARNING: Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.
DANGER: Indicates a hazardous situation, which, if not avoided, will result in death or serious injury.
When assembling building:
Use appropriate safety practices during assembly of building. Hard hats are recommended to prevent injury to head. Gloves and other heavy clothing are recommended to prevent cuts and abrasions to hands and other body parts. Beware of all pinch points when assembling building components. Appropriate erection equipment and proper training in the operation of this equipment, are important factors for the safe erection of building. Reading, understanding, and following the instructions in this book are also very important for the safe assembly of this building. Sioux Steel Company includes all reasonable means for accident prevention, except a safe and careful operator.
If any decals become damaged, detached, or illegible, contact your dealer or Sioux Steel Company at (800)-557-4689 for free replacements.
After building is complete:
To ensure building remains safe, follow the maintenance schedule found at the end of this manual.
If building is damaged:
If damage to building occurs, access in or around building should be restricted to inspection only. Immediately contact your dealer or Sioux Steel Warranty Department at (800) 557-4689. Repair of damages should be implemented as soon as practical, with appropriate PRO-TEC replacement parts.
3
COMPONENTS
192593- PURLIN BRACE 2.0" (10' BAY)192591- PURLIN BRACE 2.5" (12' BAY)192590- PURLIN BRACE 3.5" (16' BAY)
192595- MOUNT PURLIN
1576301/4" X 1 1/4"DRILL SCREW
172249BRACKET
ANGLE MOUNT
1665435/8" NYLOCK NUT
1608885/8" X 1 1/2" BOLT
191004LHMOUNT END WALL
TOWER LH
191004RHMOUNT END WALL
TOWER RH
4
COMPONENTS (cont)
1921038 TBG- 3SQx10gax95.5" 192498 TBG- 3SQx10gax104.5"
192493 192469 8x4x1/8x137.5" 8x4x1/8x184.5" TOWER TOWER192460 192485 8x4x1/8x208.5" 8x4x1/8x232.5" TOWER TOWER
192478 TBG- 6x3x1/8x192"191074 TBG- 6x3x1/8x216"
194344RH 10x4x3/16x20' BASE TOWER RH
194344LH 10x4x3/16x20' BASE TOWER LH
194344 10x4x3/16x20' BASE TOWER
192496 10x4x3/16x246" BASE TOWER
192496LH 10x4x3/16x246" BASE TOWER LH
194390 194402 194404 10x4x3/16x52" 10x4x3/16x76" 10x4x3/16x100" TOP TOWER TOP TOWER TOP TOWER
194385LH 194388LH 10x4x3/16x137.5" 10x4x3/16x184.5" TOWER TOWER194392LH 194406LH 10x4x3/16x208.5" 10x4x3/16x232.5" TOWER TOWER
193720 (HEADER) TBG- 10x4x3/16x192"193766 (HEADER) TBG- 10x4x3/16x216"
5
END WALL PARTS LIST
70' SENTRY SOLID END WALL W/ PW LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 28
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 192496 10x4x3/16x246" BASE TOWER 2
7 192493 8x4x1/8x137.5" TOWER 2
8 191074 TBG- 6 x 3 x 1/8 x 216" 2
9 192478 TBG- 6 x 3 x 1/8 x 192" 4
10 191038 TBG- 3SQ x 10ga x 95.5" 2
70' SENTRY 18' DOOR END WALL W/ PW LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 24
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 192496LH 10x4x3/16x246" BASE TOWER LH 2
7 192493 8x4x1/8x137.5" TOWER 2
8 193766 TBG- 10 x 4 x 3/16 x 216" 1
9 192478 TBG- 6 x 3 x 1/8 x 192" 4
10 191038 TBG- 3SQ x 10ga x 95.5" 2
70' SENTRY 2-16' DOORS END WALL W/ PW LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 20
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 192496LH 10x4x3/16x246" BASE TOWER LH 2
7 194385LH 10x4x3/16x137.5" TOWER LH 2
8 193720 TBG- 10 x 4 x 3/16 x 192" 2
9 191074 TBG- 6 x 3 x 1/8 x 216" 2
10 191038 TBG- 3SQ x 10ga x 95.5" 2
6
END WALL PARTS LIST
70' SENTRY SOLID END WALL W/ 6' LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 28
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344 10x4x3/16x20' BASE TOWER 2
7 194390 10x4x3/16x52" TOP TOWER 2
8 192469 8x4x1/8x184.5" TOWER 2
9 191074 TBG- 6 x 3 x 1/8 x 216" 2
10 192478 TBG- 6 x 3 x 1/8 x 192" 4
11 192498 TBG- 3SQ x 10ga x 104.5" 2
70' SENTRY 18' DOOR END WALL W/ 6' LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 24
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344LH 10x4x3/16x20' BASE TOWER LH 1
7 1943447RH 10x4x3/16x20' BASE TOWER RH 1
8 194390 10x4x3/16x52" TOP TOWER 2
9 192469 8x4x1/8x184.5" TOWER 2
10 193766 TBG- 10 x 4 x 3/16 x 216" 1
11 192478 TBG- 6 x 3 x 1/8 x 192" 4
11 192498 TBG- 3SQ x 10ga x 104.5" 2
70' SENTRY 2-16' DOORS END WALL W/ 6' LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 20
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344LH 10x4x3/16x20' BASE TOWER LH 1
7 1943447RH 10x4x3/16x20' BASE TOWER RH 1
8 194390 10x4x3/16x52" TOP TOWER 2
9 194388LH 10x4x3/16x184.5" TOWER LH 2
10 193766 TBG- 10 x 4 x 3/16 x 192" 2
11 191074 TBG- 6 x 3 x 1/8 x 216" 2
11 192498 TBG- 3SQ x 10ga x 104.5" 2
7
END WALL PARTS LIST
70' SENTRY SOLID END WALL W/ 8' LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 28
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344 10x4x3/16x20' BASE TOWER 2
7 194402 10x4x3/16x76" TOP TOWER 2
8 192460 8x4x1/8x208.5" TOWER 2
9 191074 TBG- 6 x 3 x 1/8 x 216" 2
10 192478 TBG- 6 x 3 x 1/8 x 192" 4
11 192498 TBG- 3SQ x 10ga x 104.5" 2
70' SENTRY 18' DOOR END WALL W/ 8' LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 24
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344LH 10x4x3/16x20' BASE TOWER LH 1
7 194344RH 10x4x3/16x20' BASE TOWER RH 1
8 194402 10x4x3/16x76" TOP TOWER 2
9 192460 8x4x1/8x208.5" TOWER 2
10 193766 TBG- 10 x 4 x 3/16 x 216" 1
11 192478 TBG- 6 x 3 x 1/8 x 192" 4
12 192479 TBG- 3SQ x 10ga x 103" 2
70' SENTRY 2-16' DOORS END WALL W/ 8' LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 20
4 192595 MOUNT PURLIN 8
5
192593 PURLIN BRACE 2.0" (10' BAY)
4192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344LH 10x4x3/16x20' BASE TOWER LH 1
7 194344RH 10x4x3/16x20' BASE TOWER RH 1
8 194402 10x4x3/16x76" TOP TOWER 2
9 194392LH 10x4x3/16x208.5" TOWER LH 2
10 193720 TBG- 10 x 4 x 3/16 x 192" 2
11 191074 TBG- 6 x 3 x 1/8 x 216" 2
11 192498 TBG- 3SQ x 10ga x 104.5" 2
8
END WALL PARTS LIST
11 192498 TBG- 3SQ x 10ga x 104.5" 2
11 192498 TBG- 3SQ x 10ga x 104.5" 2
11 192498 TBG- 3SQ x 10ga x 104.5" 2
ITEM NO. PART NUMBER DESCRIPTION
70' SENTRY SOLID END WALL W/ 10' LEG
QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 28
4
5
192595 MOUNT PURLIN 8
4
192593 PURLIN BRACE 2.0" (10' BAY)
192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344 10x4x3/16x20' BASE TOWER 2
7 194404 10x4x3/16x100" TOP TOWER 2
8 192485 8x4x1/8x232.5" TOWER 2
9 191074 TBG- 6 x 3 x 1/8 x 216" 2
10 192478 TBG- 6 x 3 x 1/8 x 192" 4
ITEM NO. PART NUMBER DESCRIPTION
70' SENTRY 18' DOOR END WALL W/ 10' LEG
QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 24
4
5
192595 MOUNT PURLIN 8
4
192593 PURLIN BRACE 2.0" (10' BAY)
192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344LH 10x4x3/16x20' BASE TOWER LH 1
7 194344RH 10x4x3/16x20' BASE TOWER RH 1
8 194404 10x4x3/16x100" TOP TOWER 2
9 192485 8x4x1/8x232.5" TOWER 2
10 193766 TBG- 10 x 4 x 3/16 x 216" 1
11 192478 TBG- 6 x 3 x 1/8 x 192" 4
70' SENTRY 2-16' DOORS END WALL W/ 10' LEG
ITEM NO. PART NUMBER DESCRIPTION QTY.
1 191004LH MOUNT END WALL TOWER LH 4
2 191004RH MOUNT END WALL TOWER RH 4
3 172249 BRACKET ANGLE MOUNT 20
4
5
192595 MOUNT PURLIN 8
4
192593 PURLIN BRACE 2.0" (10' BAY)
192591 PURLIN BRACE 2.5" (12' BAY)
192590 PURLIN BRACE 3.5" (16' BAY)
6 194344LH 10x4x3/16x20' BASE TOWER LH 1
7 194344RH 10x4x3/16x20' BASE TOWER RH 1
8 194404 10x4x3/16x100" TOP TOWER 2
9 194406LH 10x4x3/16x232.5" TOWER LH 2
10 193720 TBG- 10 x 4 x 3/16 x 192" 2
11 191074 TBG- 6 x 3 x 1/8 x 216" 2
9
TOOLS AND EQUIPMENT (CUSTOMER SUPPLIED)
Drilling Tools: 3/8” Power Drill (for drill screws) 3/16” drill bit (for pilot drilling drill screws)
Measuring Tools: 100’ Tape Measure
Hand Tools: Drift Pin (for aiding hole alignment) Socket & Wrench Sizes 3/8” & 15/16" Impact Wrench (pneumatic or electric)
Special Tools: Movable Scaffolding or Man Lift
Materials: 5/8" washers and nuts (enough for base of end wall towers)
BOLT INSTALLATION
Bolts should be installed to a snug-tight condition, which is defined as: the tightness attained by either a few impacts of an impact wrench or the full effort of a worker with a wrench that brings the connected plates in to firm contact.
10
TOWER CONNECTION
5/8" X 1 1/2" BOLT (160888)5/8" NYLOCK NUT (166543)
NOTCH MOUNT
TOWER
191004RH
FOR CLEARANCE
INSIDE OF STRUCTURE
191004LH
IF REQUIREDLOWER CHORDOF END RAFTER
TOWERS TO
191004LH
RAFTER
TOWER
OUTSIDE OF STRUCTURE
END WALL
OUTLINE OF
191004RH
BEND MOUNT
LOWER CHORDOF END RAFTER
5/8" NUT & WASHERCUSTOMER SUPPLIED
TOWER TO FOUNDATION
utilizing 1/4" x 1 1/4" drill screws (157630). "Mount End Wall Towers" will need to be bent to match outline of rafter. Refer to drawings below for details.
INSTALLATION INSTRUCTIONS
drawing on the right for details.
8FT LEG 2-16' DOORS END WALL- PG 22 10FT LEG SOLID END WALL- PG 238FT LEG SOLID END WALL- PG 20 8FT LEG 18' DOOR END WALL- PG 21
NOTE: Refer to proper end wall layout above and instructions below and on the next page for
PW LEG SOLID END WALL- PG 14 PW LEG 18' DOOR END WALL- PG 15
where shown in layout utilizing customer
END WALL LAYOUT REFERENCE LIST
PW LEG 2-16' DOORS END WALL- PG 16 6FT LEG SOLID END WALL- PG 176FT LEG 18' DOOR END WALL- PG 18 6FT LEG 2-16' DOORS END WALL- PG 19
1/4" X 1 1/4" DRILLSCREWS (157630)
10FT LEG 18' DOOR END WALL- PG 24 10FT LEG 2-16' DOORS END WALL- PG 25
supplied 5/8" washers and nuts. Refer to
installation of end wall.
Step 1 If required, assemble Base, Intermediate, and Top towers as shown in layout. Utilize 5/8" x 1 1/2" bolts (160888) and 5/8" nylock nuts (166543) to secure Towers together. Refer to drawing on the right for details.
Step 2 Secure assembled Towers to concrete anchors
Step 3 Install LH (191004LH) and RH (191004RH) "Mount End Wall Towers" to Towers and End Rafter
11
(2) 5/8" X 1 1/2" BOLT (160888)
TOWER
& LAYOUTS)(SEE PARTS LISTPURLIN BRACE
(157630)DRILL SCREWS
(192595)(2) MOUNT PURLIN
(8) 1/4" X 1 1/4"
RAFTERCENTER OF
PURLIN BRACE INSTALLATION
(2) 5/8" NYLOCK NUT (166543)
NOTCHREPRESENTS
LOWER CHORDOF RAFTER
3X3 TUBE TO TOWER
(172249)MOUNT
BRACKETANGLE
(172249)MOUNT
SCREWS (157630)(8) 1/4" X 1 1/4" DRILL
for locations and details.
BRACKET ANGLEMOUNT (172249)
utilizing (2) 5/8" x 1 1/2" bolts (160888) and 5/8" nylock nuts (166543).
PER BRACKET ANGLEMOUNT3X3 TUBE TO RAFTER
Refer to End Wall Layout and drawing to the right
TOWER
INSTALLATION INSTRUCTIONS
Step 5 Install 3X3, 3X6, and Header utilizing Bracket Angle Mounts (172249) and 1/4" x 1 1/4" drill screws (157630). Refer to End Wall Layout and drawings below for locations and details.
Step 4 Install (1) Purlin Brace (see parts lists) and (2) Mount Purlin (192595) at each tower location.
a) Install one "Mount Purlin" on end rafter at tower location and one on the adjacent center rafter by utilizing (8) 1/4" x 1 1/4" drill screws (157630). b) Install "Purlin Brace" to "Mount Purlins" by
BRACKETANGLE
OUTLINE OF RAFTER
BEND BRACKETANGLE MOUNT TO
RAFTER BEND BRACKETANGLE MOUNT TOOUTLINE OF RAFTER
RAFTER
3X6 TUBE TO RAFTER
BEND BRACKETANGLE MOUNT TO
OUTLINE OF RAFTER
HEADER TO TOWER
TOWER
3X6 TUBE TO TOWER
12
BRACKET
1907673x3x7'
DOOR POST
FOR WALK-IN DOORLOCATION AND WIDTHNEEDED FOR DESIREDOF END WALL WHERE
(172249)MOUNTANGLEBRACKET
MOUNTPER BRACKET ANGLESCREWS (157630)(8) 1/4" X 1 1/4" DRILL
TRIM BOTTOM TUBE
IN DOORHEIGHT FOR WALK-TUBE TO REQUIRED
END WALL HORZIONTAL
(172249)MOUNTANGLEBRACKET
(172249)MOUNTANGLE
BRACKET
(172249)MOUNTANGLE
DOOR POST3x3x7'190767
ADJUST EXISITNG
1/2" ANCHORS, WASHERS,& NUTS (CUSTOMER SUPPLIED)TO MOUNT WALK-IN DOORTOWERS TO FOUNDATION
IS ADJUSTABLEDOOR WIDTH
WALK IN DOOR FRAMING (OPTIONAL)
Note: Walk-in door option only applicable if ordered.
INSTALLATION INSTRUCTIONS
Install walk-in door where desired and as shown below.
13
38
1
TO FOUNDATIONFOR SECURING TOWERS
3
3
3 3
3
2
2
2
1
1
3
1
3
3 33
3
3
3
3
3
3
3
3
3
333
6 6
77
8
9
9 9
910
10
3
3
3
3
2
REFER TO STEP 2 (PG 11)
3
9'-6"16'-4"9'-6"
9'-0"
18'-4" 16'-4"
3 1/2"
BEND TO3
OUTLINEOF RAFTER
CUT TUBE TOOUTLINE OF
RAFTER
3
FOR INSTALLING BRACKETREFER TO STEP 5 (PG 12)
3
3
ANGLE MOUNTS3
4
CENTER
4
70' SENTRY SOLID END WALL W/PW LEG
4
REFER TO PART LIST ON PAGE 6 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
5
5
54
RAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4 4 4
4
2
11-12) FOR INSTALLING
54
TOWERS & PURLINS
REFER TO STEP 3 & 4 (PGS
1
14
2
3 32X
TO FOUNDATIONFOR SECURING TOWERS
2
3
2
2
3
3
1
1
1
1
3
3 3
3
3
3
3
3
3
3
3
3
33
6 6
77
8
9
9 9
91010
3
3
3REFER TO STEP 2 (PG 11)
HEADER HEIGHTIS ADJUSTABLE
2X
16'-4"9'-6"
9'-0"
18'-4" 16'-4" 9'-6"
3 1/2"
18'-0"
54
1
TOWERS & PURLINS11-12) FOR INSTALLING
REFER TO STEP 3 & 4 (PGS
2
OUTLINEOF RAFTER
BEND TO3
CUT TUBE TOOUTLINE OF
RAFTER
4 RAFTER4
70' SENTRY 18' DOOR END WALL W/PW LEG
4
REFER TO PART LIST ON PAGE 6 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
5
5
5
CENTER4RAFTER
END
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
4
4
3
3
REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET
ANGLE MOUNTS
15
70' SENTRY 2-16' DOORS END WALL W/PW LEG
4
4
REFER TO PART LIST ON PAGE 6 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
5
5
5
CENTERRAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
4
4
4
4
3
8
FOR SECURING TOWERSTO FOUNDATION
3
3
2
2
2
2
31
1
1
3
3 33
3
3
3
3
6
IS ADJUSTABLEHEADER HEIGHT
2X
1
77
9
8
6
1010
3
3
33
3
2X
HEADER HEIGHTIS ADJUSTABLE
2X
REFER TO STEP 2 (PG 11)
9
2X
18'-4"
16'-0"
16'-4"
16'-0"
9'-6"9'-6"
9'-6"
16'-4"
3 1/2"
1
TOWERS & PURLINS
54
REFER TO STEP 3 & 4 (PGS11-12) FOR INSTALLING
2
3
REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET
ANGLE MOUNTS
BEND TO
OF RAFTEROUTLINE
3
CUT TUBE TOOUTLINE OF
RAFTER
16
2
TOWERS & PURLINS11-12) FOR INSTALLING
54
REFER TO STEP 3 & 4 (PGS
1
FOR INSTALLING BRACKETANGLE MOUNTS
REFER TO STEP 5 (PG 12)
33
3
3
BEND TO3
OF RAFTEROUTLINE
CUT TUBE TOOUTLINE OF
RAFTER
70' SENTRY SOLID END WALL W/6' LEG
4
NUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.REFER TO PART LIST ON PAGE 7 OF THIS MANUAL FOR ITEM
5
5
5
5
RAFTERCENTER
RAFTER
ITEM 5 PART # IS
ENDBAY SPACING
DEPENDENT ON
4
4
4
4
4
4 4
3
2
TO FOUNDATIONFOR SECURING TOWERS
3
3
33
2
2
2
REFER TO STEP 2 (PG 11)
1
1
1
1
3
3 33
3
3
3
3
3
3
3
33
333
66 88
9
10
10 10
1011
11
3
3
3
3
3
3
9
7 7
3
REFER TO STEP 1 (PG11)FOR SECURING TOWERSTOGETHER
9'-6"
12'-3"
18'-4" 16'-4"16'-4"
3 1/2"
9'-6"
17
3
8
FOR SECURING TOWERSTO FOUNDATION
3
3
2
2
2
2
1
1
1
1
3
3 3
3
3
3
3
3
3
3
33
33
6
7 99
10
11
1111
1112
12
3
3
3
3
3
8TOGETHERFOR SECURING TOWERS
2X
REFER TO STEP 2 (PG 11)
REFER TO STEP 1 (PG11)
HEADER HEIGHTIS ADJUSTABLE
2X
9'-6"
12'-3"
18'-4" 16'-4"16'-4"
3 1/2"
9'-6"
18'-0"
4
70' SENTRY 18' DOOR END WALL W/6' LEG
4
REFER TO PART LIST ON PAGE 7 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
5
5
5
CENTERRAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
4
4
4
4
3
ANGLE MOUNTSFOR INSTALLING BRACKETREFER TO STEP 5 (PG 12)
3BEND TO
OF RAFTEROUTLINE
3
CUT TUBE TOOUTLINE OF
RAFTER
1
TOWERS & PURLINS11-12) FOR INSTALLING
54
REFER TO STEP 3 & 4 (PGS
2
18
1
TOWERS & PURLINS11-12) FOR INSTALLING
54
REFER TO STEP 3 & 4 (PGS
2
70' SENTRY 2-16' DOORS END WALL W/6' LEG
4
4
REFER TO PART LIST ON PAGE 7 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
5
5
5
CENTERRAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
4
4
4
4
3
3
REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET
ANGLE MOUNTS
BEND TO
OF RAFTEROUTLINE
3
CUT TUBE TOOUTLINE OF
RAFTER2X
2X
8
2
FOR SECURING TOWERSTO FOUNDATION
3
3
33
2
10
IS ADJUSTABLEHEADER HEIGHT
2X
2
1
1
1
1 3
3 33
3
3
3
3
7 6 99
11
210
1212
3
3
3
3
11
8
REFER TO STEP 2 (PG 11)
FOR SECURING TOWERSTOGETHER
REFER TO STEP 1 (PG 11)
HEADER HEIGHTIS ADJUSTABLE
2X
16'-0" 12'-3"
18'-4" 16'-4"16'-4"9'-6" 9'-6"
3"16'-0"
19
4
REFER TO STEP 3 & 4 (PGS
TOWERS & PURLINS11-12) FOR I NSTALLING
5
2
1BEND TO
3OF RAFTER
OUTLINE
CUT TUBE TOOUTLINE OF
RAFTER
3
33
REFER TO STEP 5 (PG 12)
ANGLE MOUNTSON MOUNTING BRACKET
3
5
70' SENTRY SOLID END WALL W/8' LEGNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.REFER TO PART LIST ON PAGE 8 OF THIS MANUAL FOR ITEM
45
5
5
RAFTERCENTER
RAFTER
ITEM 5 PART # IS
ENDBAY SPACINGDEPENDENT ON
4
4
4 44
4 4
2
TO FOUNDATIONFOR SECURING TOWERS
3
3
33
2
2
3
REFER TO STEP 2 (PG 11)
2
1
1
1
1
3
3 33
3
3
3
3
3
3
3
33
333
66 8
8
9
10
10 10
1011
11
3
3
3
3
3
3
9
7 7
3
REFER TO STEP 1 (PG11)FOR SECURING TOWERSTOGETHER
9'-6"
13'-3"
18'-4" 16'-4"16'-4"
4"
9'-6"20
4
70' SENTRY 18' DOOR END WALL W/8' LEG
4
REFER TO PART LIST ON PAGE 8 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
5
5
5
CENTERRAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
4
4
4
4
BEND TO
OF RAFTEROUTLINE 3
CUT TUBE TOOUTLINE OF
RAFTER
3
ANGLE MOUNTSFOR INSTALLING BRACKETREFER TO STEP 5 (PG 12)
3
3
2
FOR SECURING TOWERSTO FOUNDATION
3
3
2
8
2
2
1
1
1
1
3
3
TOGETHERFOR SECURING TOWERS
2X3
3
3
3
3
3
3
33
33
6 799
10
11
1111
1112
12
3
3
3
3
3
3
8
REFER TO STEP 2 (PG 11)
REFER TO STEP 1 (PG11)
HEADER HEIGHTIS ADJUSTABLE
2X
18'-0"
3 1/2"
9'-6"
13'-3"
18'-4" 16'-4"16'-4" 9'-6"
1
TOWERS & PURLINS11-12) FOR INSTALLING
54
REFER TO STEP 3 & 4 (PGS
2
21
1
TOWERS & PURLINS11-12) FOR INSTALLING
54
REFER TO STEP 3 & 4 (PGS
2
2X2X
8
2
FOR SECURING TOWERSTO FOUNDATION
3
3
33
2
2
2
3
1
1
1
IS ADJUSTABLEHEADER HEIGHT
2X
3
3 33
3
3
3
3
7 699
11
12
10
12
TOGETHERFOR SECURING TOWERS
3
10 3
3
11
8
REFER TO STEP 2 (PG 11)
1
REFER TO STEP 1 (PG 11)
HEADER HEIGHTIS ADJUSTABLE
2X
16'-0"
9'-6"
16'-0"
18'-4" 16'-4"16'-4"
13'-3"
3"
9'-6"
5
4
70' SENTRY 2-16' DOORS END WALL W/8' LEG REFER TO PART LIST ON PAGE 8 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
45
5
CENTERRAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
4
4
4
4
BEND TO
OF RAFTEROUTLINE 3
CUT TUBE TOOUTLINE OF
RAFTER
3
3
REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET
ANGLE MOUNTS
22
BEND TO
OF RAFTEROUTLINE
3
CUT TUBE TOOUTLINE OF
RAFTER
ANGLE MOUNTS
3
REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET
3
3
3
70' SENTRY SOLID END WALL W/10' LEG
44
4
4
54
REFER TO PART LIST ON PAGE 9 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
4
5
5
CENTERRAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
2
TOWERS & PURLINS11-12) FOR INSTALLING
54
REFER TO STEP 3 & 4 (PGS
1
3
9
77
3
3
REFER TO STEP 2 (PG 11)FOR SECURING TOWERSTO FOUNDATION
3
3
33
2
22
8
1
1
1
1
3
3 33
3
3 3
3
3
3
3
33
333
66
8
2
9
10
10 10
1011
11
3
3
3
3
3
REFER TO STEP 1 (PG11)FOR SECURING TOWERSTOGETHER
14'-3"
9'-6" 18'-4" 16'-4"16'-4"
3 1/2"
9'-6"
23
FOR SECURING TOWERS2
TO FOUNDATIONFOR SECURING TOWERS 3
3
2
2X2
2
1
1
1
1
3
3 3
3
3
3
3
3
3
3
33
33
6 7 99
10
11
1111
1112
12
3
3
3
3
3
8
8
3
REFER TO STEP 2 (PG 11)
TOGETHER
REFER TO STEP 1 (PG11)
HEADER HEIGHTIS ADJUSTABLE
2X
9'-6"
14'-3"
18'-4" 16'-4"16'-4"
3 1/2"
18'-0"
9'-6"
REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET
ANGLE MOUNTS
3
3
BEND TO 3
OF RAFTEROUTLINE
CUT TUBE TOOUTLINE OF
RAFTER
1
TOWERS & PURLINS11-12) FOR INSTALLING
54
REFER TO STEP 3 & 4 (PGS
2
70' SENTRY 18' DOOR END WALL W/10' LEG
4
NUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.REFER TO PART LIST ON PAGE 9 OF THIS MANUAL FOR ITEM
5
5
5
5
RAFTERCENTER
RAFTER
ITEM 5 PART # IS
ENDBAY SPACING
DEPENDENT ON
4
4
4
4
4
4 4
24
2X2X
HEADER HEIGHT
8
10
IS ADJUSTABLEHEADER HEIGHT
3
3
33
2
TO FOUNDATIONFOR SECURING TOWERS
2
2
1
1
1
1
3
3 33
3
3
3
7 6
99
11
2
10
1212
3
3
3
3
11
8
REFER TO STEP 2 (PG 11)
FOR SECURING TOWERSTOGETHER
IS ADJUSTABLE
2XREFER TO STEP 1 (PG 11)
32X
16'-0"
9'-6"
16'-0"
18'-4" 16'-4"16'-4"
14'-3"
3 1/2"
9'-6"
4
70' SENTRY 2-16' DOORS END WALL W/10' LEG
4
REFER TO PART LIST ON PAGE 9 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.
5
5
5
5
CENTERRAFTER
RAFTEREND
ITEM 5 PART # ISDEPENDENT ON
BAY SPACING
4
4
4
4
4
4
4
TOWERS & PURLINS11-12) FOR INSTALLING
5
1
REFER TO STEP 3 & 4 (PGS
2BEND TO
OF RAFTEROUTLINE
3
CUT TUBE TOOUTLINE OF
RAFTER
3
3
REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET
ANGLE MOUNTS
25
MAINTENANCE SCHEDULE
1. One Week Inspection a. The key visual indicator of adequate tension in the building fabric cover and end wall
panel is to ensure all creases and wrinkles in the fabric are removed. Check the ratchet straps for tightness and adjust as necessary. Refer to step 9 of cover installation manual for recommended torque settings for 1" and 2" ratchets.
b. Punctures in the fabric cover caused by accidental damage should be repaired
immediately. The fabric requires a product specific heat seam weld repair. Contact your local Sioux Steel Pro-Tec® building dealer or manufacturer to schedule service.
c. Ensure all tension cables are taut. Cables should not sag. Adjust turnbuckles as
necessary.
2. Installation Adjustment a. The building and end wall panels cover on your SIOUX PRO-TEC® Sentry Building
may relax after installation. It is critical to keep the cover taut (snug) over the rafters and end wall panels taut over end wall framing to prevent wear and ensure a long life. Tighten ratchets and adjust cables as required.
3. Annual Maintenance
a. Repeat 1 Week Inspection (listed above) a minimum of (4) times a year. b. Visually inspect each cross cable for signs of wear and check turnbuckle tension.
Replace and/ or tighten as necessary. c. Check all base plate anchor studs and nuts to assure they are tight. d. Check all ratchet mount and winch bolts and nuts to assure they are tight. e. Check for premature wear of fabric cover, especially where tension is applied and where
there is direct contact with the buildings steel frame. f. Check for premature deterioration of the corrosion protection on the building components.
NOTE: Building covers and end wall panels installed in cooler weather may relax more than covers installed in warm weather. Check tight ness on covers and end wall panels installed in cooler weather on the first available sunny day and adjust cables as necessary. Severe weather conditions may also affe ct your cover, check cover after such conditions occur.
NOTE: Failure to carry out above steps will invalid ate the warranty. WARNING: FLAMMABLE MATERIAL EXPOSURE TO ANY HEAT SOURCE FOR ANY LENGTH OF TIME COULD RESULT IN DAMAGE TO THE FABRIC COVER OR END PANEL MATERIAL. EXHAUST GA SES, SPACE HEATER, WELDING SPARKS, ETC. SHOULD NOT BE ALLOWED TO GET NEAR THE FABRIC PORTION OF STRUCTURE. SIOUX STEEL COMPANY WILL NOT BE RESPONS IBLE FOR ANY DAMAGES OR LIABILITIES RESULTING FROM FAILURE TO HEED THIS WAR NING. THE COVER OR END PANEL MATERIAL STARTS TO DETERIORATE AT EXPOSURE TO 180° TEMPERATURE FOR ANY LENGTH OF TIME. PREVENT PROLONGED CONTACT FROM ANY HEAT SOURCE TO ENSURE MAXIMUM PROTECTION TO THIS MATERIAL. FOR ANY FURTH ER INFORMATION CONTACT SIOUX STEEL COMPANY.
Revised 07/14/2017
NEW PRODUCT WARRANTY PRO-TEC BUILDINGS
LIMITED WARRANTY FOR NEW SIOUX STEEL COMPANY PRODUCTS A. GENERAL PROVISIONS . “Sioux Steel” means Sioux Steel Company, 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104. The warranties described below are provided by Sioux Steel to the original purchasers of new products purchased from Sioux Steel or from an authorized Sioux Steel Dealer (the “Products”). Under these warranties, Sioux Steel will, at its option, repair or replace at its factory any Product covered under these warranties which is found to be defective in material and workmanship during the applicable warranty term or refund the purchase price paid for the defective Product. Customer will be responsible for labor charges for removing the defective Product and reinstalling the repaired or replacement Product, any premium charge for overtime labor requested of Sioux Steel and shipping charges to and from Sioux Steel’s factory. These warranties are not transferrable . B. WARRANTY PERIOD . Subject to exclusions and limitations set forth herein, each new Product is warranted for the number of years specified below. Each warranty term begins from the date of purchase regardless of delay in receipt of the Product by Customer due to the time required to process, handle, ship, assemble, construct and install the Product. Customer must retain proof of the date of purchase. Replacement parts for and repairs to the Product will be warranted only for the remainder of the original warranty term. The replacement parts for or repairs to the Product will not extend the warranty term beyond the original warranty term. Products described below include all parts, components and accessories.
PROTEC BUILDINGS Pro-Tec Poultry Buildings 1 Year Safeguard Livestock Shade 1 Year Pro-Tec Single Tube (24’, 30’, and 36’) Buildings 3 Years All Other Powder-Coated Pro-Tec Buildings in Livestock (other than Poultry) and Chemical Storage Applications 7 Years, Prorated Monthly All Other Powder-Coated Pro-Tec Buildings Except those in Livestock and Chemical Storage Applications 15 Years, Prorated Monthly All Other Hot-Dip Galvanized Pro-Tec Buildings 15 Years, Prorated Monthly Fabricated Tarp Materials (covers) 15 Years, Prorated Monthly Fabricated Tarp Materials for End Panels (All Pro-Tec Buildings) ; Rollup Sides; Curtains and Doors; Track Doors; Quarter Panels and Half Moon End Panels ( On all Building Models)
3 Years, Prorated Monthly
Proration credit will be given toward the purchase price for the replacement of fabric and tarp materials, based on Sioux Steel’s current price list at the time the warranty claim is made.
15 Year Proration Schedule: 7 Year Proration Schedule: Year 1 = 93% Year 4 – 73% Year 7 – 53% Year 10 = 33% Year 13 = 13% Year 1 = 86% Year 4 = 43% Year 7 = 0% Year 2 = 87% Year 5 = 67% Year 8 = 47% Year 11 = 27% Year 14 = 7% Year 2 = 72% Year 5 = 29% Year 3 = 80% Year 6 = 60% Year 9 = 40% year 12 = 20% Year 15 = 0% Year 3 = 58% Year 6 = 15%
Exclusions specific to Pro-Tec Buildings: Damage or loss of any kind from (1) exposure of the fabric cover or end panel material to any heat source for any length of time; (2) a failure to properly compact and engineer soils; (3) a failure to properly construct footings and foundations; and (4) exposure to conditions in excess of the design wind and snow load specifications. NOTICE: Caustic and corrosive environments can resu lt from live animal operations or storage of caustic materials. Sioux Steel reserves the right to exclude from warranty under D(4) if co nditions are deemed by it as extreme. C. ITEMS COVERED SEPARATELY . The Sioux Steel warranties do not cover any parts, components or materials that are part of the Product, or used in conjunction with the Product, that are not manufactured by Sioux Steel. Such parts, components and materials will be subject to the warranties provided by the manufacturer, if any. D. WHAT IS NOT WARRANTED . Sioux Steel does not warrant and is not responsible for the following: (1) used products; (2) modification or alteration of the Products; (3) Products that have not been properly installed or not installed in accordance with the instruction manual, improper assembly, or improper construction by any persons other than Sioux Steel employees; (4) depreciation, damage or loss caused by the use of parts, components or accessories not provided by Sioux Steel, unauthorized repairs, normal wear, lack of necessary and proper maintenance, a failure to follow operating instructions/recommendations, misuse, lack of proper protection during storage, vandalism or theft, exposure to the elements or corrosive materials, accidents or acts of nature including lightning, flooding, hail, straight winds and tornadoes; and (5) cosmetic damage or damage that does not hinder the functionality of the Products. E. LIMITATIONS OF WARRANTIES AND CUSTOMER’S REMEDI ES. To the extent permitted by law, neither Sioux Steel, the Dealer nor any person or company affiliated with either of them makes any warranties, representations, conditions or promises express or implied as to the quality, performance or freedom from defects of the Products covered by these warranties other than those set forth herein. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NEITHER SIOUX STEEL, THE DEALER, NOR ANY PERSON OR COMPANY AFFILIATED WITH EITHER OF THEM WILL BE LIABLE FOR ANY DAMAGES, INCLUDING, BUT NOT LIMITED TO, INCIDENTAL, SPECIAL, EXEMPLARY, CONSEQUENTIAL, LOST PROFITS AND REVENUES, LOST USE OF THE PRODUCTS OR ANY OTHER PROPERTY, BODILY INJURY OR PROPERTY DAMAGE CLAIMS OF ANY PERSON, LOST COMMODITIES, REMOVAL OR STORAGE COSTS FOR THE PRODUCTS, OTHER EQUIPMENT AND COMMODITIES, DAMAGE TO THE ENVIRONMENT ARISING FROM OR IN ANY MANNER RELATED TO ANY RELEASE OF HAZARDOUS MATERIALS, AND REMEDIATION EXPENSES THEREFORE, WHETHER BASED ON CONTRACT, TORT, STRICT LIABILITY OR ANY OTHER LEGAL BASIS, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO INSTANCE WILL SIOUX STEEL, THE DEALER OR ANY PERSON OR COMPANY AFFILIATED WITH EITHER OF THEM BE LIABLE TO CUSTOMER OR ANY PERSON IN AN AMOUNT IN EXCESS OF THE PURCHASE PRICE PAID BY CUSTOMER FOR THE PRODUCT. F. NO DEALER WARRANTY . THE DEALER HAS NO AUTHORITY TO MAKE ANY WARRANTY, REPRESENTATION, CONDITION OR PROMISE ON BEHALF OF SIOUX STEEL, OR TO MODIFY THE TERMS OR LIMITATIONS OF THIS WARRANTY IN ANY WAY. G. GOVERNING LAW/VENUE . These warranties, and all terms set forth herein, are governed by the laws of the State of South Dakota and, where applicable, the laws of the United States of America. Any and all disputes arising from these warranties, the purchase and use of the Products, bodily injury and property damage claims or otherwise must be venued in the South Dakota Circuit Court sitting in Minnehaha County, South Dakota. Customer agrees to such venue and waives any challenge to such court’s jurisdiction based upon lack of personal jurisdiction or inconvenience. H. SECURING WARRANTY SERVICE . In order to receive warranty services, customer must give Sioux Steel written notice of a warranty claim within 3 days of the date of discovery of the defective materials or workmanship, and Customer must complete the following steps:
(1) Obtain from Sioux Steel a Return Goods Authorization Number (“RMA Number”) by calling the Customer Service Department at 1-800-557-4689, and providing the following information:
� An explanation as to why the Product is being returned. � The name of the territory representative, Dealer or Sioux Steel salesperson from whom the Product was
purchased. � The Dealer’s identification number. � The invoice number and date of purchase. � Customer’s name, phone number, fax number, mailing address and email address. � The date that the Product will be returned.
(2) Pay the shipping charges to ship the Product to Sioux Steel’s factory, and the return shipping charges. (3) Ship the Product to Sioux Steel at 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104.