+ All Categories
Home > Documents > END WALL MANUAL - d3otus7o5uizil.cloudfront.net

END WALL MANUAL - d3otus7o5uizil.cloudfront.net

Date post: 03-Jan-2022
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
28
PRO-TEC SENTRY BUILDING 70' WIDTH END WALL MANUAL IMPORTANT - TO THE DEALER OR ERECTOR: RETURN THIS MANUAL TO THE OWNER FOR THEIR FUTURE REFERENCE SIOUX STEEL COMPANY, P.O. BOX 1265, SIOUX FALLS, SOUTH DAKOTA 57101 1-800-557-4689 MANUAL NO. 193884 REV C/MRS 8/1/17 ECN 17-141
Transcript
Page 1: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

PRO-TEC SENTRY BUILDING

70' WIDTH

END WALL MANUAL

IMPORTANT - TO THE DEALER OR ERECTOR:

RETURN THIS MANUAL TO THE OWNER FOR THEIR FUTURE REFERENCE

SIOUX STEEL COMPANY, P.O. BOX 1265, SIOUX FALLS, SOUTH DAKOTA 571011-800-557-4689

MANUAL NO. 193884REV C/MRS 8/1/17 ECN 17-141

Page 2: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

Dear Sentry Building Owner, We would like to take this opportunity to thank you for purchasing a SIOUX STEEL PRO-TEC BUILDING . We believe that it will serve you well for many years. The framework uses quality certified structural grade steel tubing. All welded rafter assemblies are powder coated or hot-dipped galvanized to provide maximum corrosion protection. We believe in providing QUALITY, RELIABILITY, DURABILITY, VERSATILITY , and COMMITMENT to meet the needs of our customer. Should you have any questions or comments during or following the installation, please feel free to call your SIOUX STEEL PRO-TEC BUILDING dealer or manufacturer. We will be glad to assist you in any way we can.

IMPORTANT Improper Site Preparation, Assembly and Maintenance may invalidate warranty and cause unnecessary and costly mistakes.

READ MANUAL FIRST

If you have any questions contact Sioux Steel Co. at 1-800-557-4689

Procedure For Viewing Sentry Manuals On-Line: • Log on to siouxsteel.com.

• Select Dealer Login in upper right hand corner.

• Enter Username, Password and select Submit.

If you don’t have a username and password, contact your dealer or

Sioux Steel Company Customer Service at 1-800-557-4689.

• Select the Engineering Manuals folder in the center of the screen.

• Select the ProTec Manuals folder.

• Select the Sentry folder.

• Based on manual description select the desired manual you wish to open, view

and/or print.

• A second tab will open up with a PDF file of the desired manual.

• If you wish to print the manual, select the printer icon in the upper left hand

corner.

Page 3: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

TABLE OF CONTENTS

SAFETY PAGE 3

COMPONENTS PAGE 4-5

END WALL PARTS LIST PAGE 6-9

TOOLS & EQUIPMENT PAGE 10

INSTALLATION INSTRUCTIONS PAGE 11-13

PW LEG SOLID END WALL PAGE 14

PW LEG 18' DOOR END WALL PAGE 15

PW LEG 2-16' DOORS END WALL PAGE 16

6FT LEG SOLID END WALL PAGE 17

6FT LEG 18' DOOR END WALL PAGE 18

6FT LEG 2-16' DOORS END WALL PAGE 19

8FT LEG SOLID END WALL PAGE 20

8FT LEG 18' DOOR END WALL PAGE 21

8FT LEG 2-16' DOORS END WALL PAGE 22

10FT LEG SOLID END WALL PAGE 23

10FT LEG 18' DOOR END WALL PAGE 24

10FT LEG 2-16' DOORS END WALL PAGE 25

MAINTENANCE SCHEDULE PAGE 26-27

WARRANTY STATEMENTS PAGE 28

2

Page 4: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

SAFETY

Watch for this symbol. It points out important safety precautions. It means “Attention – Be Alert!”

DEFINITIONS:CAUTION: Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.

WARNING: Indicates a hazardous situation, which, if not avoided, could result in death or serious injury.

DANGER: Indicates a hazardous situation, which, if not avoided, will result in death or serious injury.

When assembling building:

Use appropriate safety practices during assembly of building. Hard hats are recommended to prevent injury to head. Gloves and other heavy clothing are recommended to prevent cuts and abrasions to hands and other body parts. Beware of all pinch points when assembling building components. Appropriate erection equipment and proper training in the operation of this equipment, are important factors for the safe erection of building. Reading, understanding, and following the instructions in this book are also very important for the safe assembly of this building. Sioux Steel Company includes all reasonable means for accident prevention, except a safe and careful operator.

If any decals become damaged, detached, or illegible, contact your dealer or Sioux Steel Company at (800)-557-4689 for free replacements.

After building is complete:

To ensure building remains safe, follow the maintenance schedule found at the end of this manual.

If building is damaged:

If damage to building occurs, access in or around building should be restricted to inspection only. Immediately contact your dealer or Sioux Steel Warranty Department at (800) 557-4689. Repair of damages should be implemented as soon as practical, with appropriate PRO-TEC replacement parts.

3

Page 5: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

COMPONENTS

192593- PURLIN BRACE 2.0" (10' BAY)192591- PURLIN BRACE 2.5" (12' BAY)192590- PURLIN BRACE 3.5" (16' BAY)

192595- MOUNT PURLIN

1576301/4" X 1 1/4"DRILL SCREW

172249BRACKET

ANGLE MOUNT

1665435/8" NYLOCK NUT

1608885/8" X 1 1/2" BOLT

191004LHMOUNT END WALL

TOWER LH

191004RHMOUNT END WALL

TOWER RH

4

Page 6: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

COMPONENTS (cont)

1921038 TBG- 3SQx10gax95.5" 192498 TBG- 3SQx10gax104.5"

192493 192469 8x4x1/8x137.5" 8x4x1/8x184.5" TOWER TOWER192460 192485 8x4x1/8x208.5" 8x4x1/8x232.5" TOWER TOWER

192478 TBG- 6x3x1/8x192"191074 TBG- 6x3x1/8x216"

194344RH 10x4x3/16x20' BASE TOWER RH

194344LH 10x4x3/16x20' BASE TOWER LH

194344 10x4x3/16x20' BASE TOWER

192496 10x4x3/16x246" BASE TOWER

192496LH 10x4x3/16x246" BASE TOWER LH

194390 194402 194404 10x4x3/16x52" 10x4x3/16x76" 10x4x3/16x100" TOP TOWER TOP TOWER TOP TOWER

194385LH 194388LH 10x4x3/16x137.5" 10x4x3/16x184.5" TOWER TOWER194392LH 194406LH 10x4x3/16x208.5" 10x4x3/16x232.5" TOWER TOWER

193720 (HEADER) TBG- 10x4x3/16x192"193766 (HEADER) TBG- 10x4x3/16x216"

5

Page 7: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

END WALL PARTS LIST

70' SENTRY SOLID END WALL W/ PW LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 28

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 192496 10x4x3/16x246" BASE TOWER 2

7 192493 8x4x1/8x137.5" TOWER 2

8 191074 TBG- 6 x 3 x 1/8 x 216" 2

9 192478 TBG- 6 x 3 x 1/8 x 192" 4

10 191038 TBG- 3SQ x 10ga x 95.5" 2

70' SENTRY 18' DOOR END WALL W/ PW LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 24

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 192496LH 10x4x3/16x246" BASE TOWER LH 2

7 192493 8x4x1/8x137.5" TOWER 2

8 193766 TBG- 10 x 4 x 3/16 x 216" 1

9 192478 TBG- 6 x 3 x 1/8 x 192" 4

10 191038 TBG- 3SQ x 10ga x 95.5" 2

70' SENTRY 2-16' DOORS END WALL W/ PW LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 20

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 192496LH 10x4x3/16x246" BASE TOWER LH 2

7 194385LH 10x4x3/16x137.5" TOWER LH 2

8 193720 TBG- 10 x 4 x 3/16 x 192" 2

9 191074 TBG- 6 x 3 x 1/8 x 216" 2

10 191038 TBG- 3SQ x 10ga x 95.5" 2

6

Page 8: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

END WALL PARTS LIST

70' SENTRY SOLID END WALL W/ 6' LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 28

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344 10x4x3/16x20' BASE TOWER 2

7 194390 10x4x3/16x52" TOP TOWER 2

8 192469 8x4x1/8x184.5" TOWER 2

9 191074 TBG- 6 x 3 x 1/8 x 216" 2

10 192478 TBG- 6 x 3 x 1/8 x 192" 4

11 192498 TBG- 3SQ x 10ga x 104.5" 2

70' SENTRY 18' DOOR END WALL W/ 6' LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 24

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344LH 10x4x3/16x20' BASE TOWER LH 1

7 1943447RH 10x4x3/16x20' BASE TOWER RH 1

8 194390 10x4x3/16x52" TOP TOWER 2

9 192469 8x4x1/8x184.5" TOWER 2

10 193766 TBG- 10 x 4 x 3/16 x 216" 1

11 192478 TBG- 6 x 3 x 1/8 x 192" 4

11 192498 TBG- 3SQ x 10ga x 104.5" 2

70' SENTRY 2-16' DOORS END WALL W/ 6' LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 20

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344LH 10x4x3/16x20' BASE TOWER LH 1

7 1943447RH 10x4x3/16x20' BASE TOWER RH 1

8 194390 10x4x3/16x52" TOP TOWER 2

9 194388LH 10x4x3/16x184.5" TOWER LH 2

10 193766 TBG- 10 x 4 x 3/16 x 192" 2

11 191074 TBG- 6 x 3 x 1/8 x 216" 2

11 192498 TBG- 3SQ x 10ga x 104.5" 2

7

Page 9: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

END WALL PARTS LIST

70' SENTRY SOLID END WALL W/ 8' LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 28

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344 10x4x3/16x20' BASE TOWER 2

7 194402 10x4x3/16x76" TOP TOWER 2

8 192460 8x4x1/8x208.5" TOWER 2

9 191074 TBG- 6 x 3 x 1/8 x 216" 2

10 192478 TBG- 6 x 3 x 1/8 x 192" 4

11 192498 TBG- 3SQ x 10ga x 104.5" 2

70' SENTRY 18' DOOR END WALL W/ 8' LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 24

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344LH 10x4x3/16x20' BASE TOWER LH 1

7 194344RH 10x4x3/16x20' BASE TOWER RH 1

8 194402 10x4x3/16x76" TOP TOWER 2

9 192460 8x4x1/8x208.5" TOWER 2

10 193766 TBG- 10 x 4 x 3/16 x 216" 1

11 192478 TBG- 6 x 3 x 1/8 x 192" 4

12 192479 TBG- 3SQ x 10ga x 103" 2

70' SENTRY 2-16' DOORS END WALL W/ 8' LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 20

4 192595 MOUNT PURLIN 8

5

192593 PURLIN BRACE 2.0" (10' BAY)

4192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344LH 10x4x3/16x20' BASE TOWER LH 1

7 194344RH 10x4x3/16x20' BASE TOWER RH 1

8 194402 10x4x3/16x76" TOP TOWER 2

9 194392LH 10x4x3/16x208.5" TOWER LH 2

10 193720 TBG- 10 x 4 x 3/16 x 192" 2

11 191074 TBG- 6 x 3 x 1/8 x 216" 2

11 192498 TBG- 3SQ x 10ga x 104.5" 2

8

Page 10: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

END WALL PARTS LIST

11 192498 TBG- 3SQ x 10ga x 104.5" 2

11 192498 TBG- 3SQ x 10ga x 104.5" 2

11 192498 TBG- 3SQ x 10ga x 104.5" 2

ITEM NO. PART NUMBER DESCRIPTION

70' SENTRY SOLID END WALL W/ 10' LEG

QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 28

4

5

192595 MOUNT PURLIN 8

4

192593 PURLIN BRACE 2.0" (10' BAY)

192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344 10x4x3/16x20' BASE TOWER 2

7 194404 10x4x3/16x100" TOP TOWER 2

8 192485 8x4x1/8x232.5" TOWER 2

9 191074 TBG- 6 x 3 x 1/8 x 216" 2

10 192478 TBG- 6 x 3 x 1/8 x 192" 4

ITEM NO. PART NUMBER DESCRIPTION

70' SENTRY 18' DOOR END WALL W/ 10' LEG

QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 24

4

5

192595 MOUNT PURLIN 8

4

192593 PURLIN BRACE 2.0" (10' BAY)

192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344LH 10x4x3/16x20' BASE TOWER LH 1

7 194344RH 10x4x3/16x20' BASE TOWER RH 1

8 194404 10x4x3/16x100" TOP TOWER 2

9 192485 8x4x1/8x232.5" TOWER 2

10 193766 TBG- 10 x 4 x 3/16 x 216" 1

11 192478 TBG- 6 x 3 x 1/8 x 192" 4

70' SENTRY 2-16' DOORS END WALL W/ 10' LEG

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 191004LH MOUNT END WALL TOWER LH 4

2 191004RH MOUNT END WALL TOWER RH 4

3 172249 BRACKET ANGLE MOUNT 20

4

5

192595 MOUNT PURLIN 8

4

192593 PURLIN BRACE 2.0" (10' BAY)

192591 PURLIN BRACE 2.5" (12' BAY)

192590 PURLIN BRACE 3.5" (16' BAY)

6 194344LH 10x4x3/16x20' BASE TOWER LH 1

7 194344RH 10x4x3/16x20' BASE TOWER RH 1

8 194404 10x4x3/16x100" TOP TOWER 2

9 194406LH 10x4x3/16x232.5" TOWER LH 2

10 193720 TBG- 10 x 4 x 3/16 x 192" 2

11 191074 TBG- 6 x 3 x 1/8 x 216" 2

9

Page 11: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

TOOLS AND EQUIPMENT (CUSTOMER SUPPLIED)

Drilling Tools: 3/8” Power Drill (for drill screws) 3/16” drill bit (for pilot drilling drill screws)

Measuring Tools: 100’ Tape Measure

Hand Tools: Drift Pin (for aiding hole alignment) Socket & Wrench Sizes 3/8” & 15/16" Impact Wrench (pneumatic or electric)

Special Tools: Movable Scaffolding or Man Lift

Materials: 5/8" washers and nuts (enough for base of end wall towers)

BOLT INSTALLATION

Bolts should be installed to a snug-tight condition, which is defined as: the tightness attained by either a few impacts of an impact wrench or the full effort of a worker with a wrench that brings the connected plates in to firm contact.

10

Page 12: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

TOWER CONNECTION

5/8" X 1 1/2" BOLT (160888)5/8" NYLOCK NUT (166543)

NOTCH MOUNT

TOWER

191004RH

FOR CLEARANCE

INSIDE OF STRUCTURE

191004LH

IF REQUIREDLOWER CHORDOF END RAFTER

TOWERS TO

191004LH

RAFTER

TOWER

OUTSIDE OF STRUCTURE

END WALL

OUTLINE OF

191004RH

BEND MOUNT

LOWER CHORDOF END RAFTER

5/8" NUT & WASHERCUSTOMER SUPPLIED

TOWER TO FOUNDATION

utilizing 1/4" x 1 1/4" drill screws (157630). "Mount End Wall Towers" will need to be bent to match outline of rafter. Refer to drawings below for details.

INSTALLATION INSTRUCTIONS

drawing on the right for details.

8FT LEG 2-16' DOORS END WALL- PG 22 10FT LEG SOLID END WALL- PG 238FT LEG SOLID END WALL- PG 20 8FT LEG 18' DOOR END WALL- PG 21

NOTE: Refer to proper end wall layout above and instructions below and on the next page for

PW LEG SOLID END WALL- PG 14 PW LEG 18' DOOR END WALL- PG 15

where shown in layout utilizing customer

END WALL LAYOUT REFERENCE LIST

PW LEG 2-16' DOORS END WALL- PG 16 6FT LEG SOLID END WALL- PG 176FT LEG 18' DOOR END WALL- PG 18 6FT LEG 2-16' DOORS END WALL- PG 19

1/4" X 1 1/4" DRILLSCREWS (157630)

10FT LEG 18' DOOR END WALL- PG 24 10FT LEG 2-16' DOORS END WALL- PG 25

supplied 5/8" washers and nuts. Refer to

installation of end wall.

Step 1 If required, assemble Base, Intermediate, and Top towers as shown in layout. Utilize 5/8" x 1 1/2" bolts (160888) and 5/8" nylock nuts (166543) to secure Towers together. Refer to drawing on the right for details.

Step 2 Secure assembled Towers to concrete anchors

Step 3 Install LH (191004LH) and RH (191004RH) "Mount End Wall Towers" to Towers and End Rafter

11

Page 13: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

(2) 5/8" X 1 1/2" BOLT (160888)

TOWER

& LAYOUTS)(SEE PARTS LISTPURLIN BRACE

(157630)DRILL SCREWS

(192595)(2) MOUNT PURLIN

(8) 1/4" X 1 1/4"

RAFTERCENTER OF

PURLIN BRACE INSTALLATION

(2) 5/8" NYLOCK NUT (166543)

NOTCHREPRESENTS

LOWER CHORDOF RAFTER

3X3 TUBE TO TOWER

(172249)MOUNT

BRACKETANGLE

(172249)MOUNT

SCREWS (157630)(8) 1/4" X 1 1/4" DRILL

for locations and details.

BRACKET ANGLEMOUNT (172249)

utilizing (2) 5/8" x 1 1/2" bolts (160888) and 5/8" nylock nuts (166543).

PER BRACKET ANGLEMOUNT3X3 TUBE TO RAFTER

Refer to End Wall Layout and drawing to the right

TOWER

INSTALLATION INSTRUCTIONS

Step 5 Install 3X3, 3X6, and Header utilizing Bracket Angle Mounts (172249) and 1/4" x 1 1/4" drill screws (157630). Refer to End Wall Layout and drawings below for locations and details.

Step 4 Install (1) Purlin Brace (see parts lists) and (2) Mount Purlin (192595) at each tower location.

a) Install one "Mount Purlin" on end rafter at tower location and one on the adjacent center rafter by utilizing (8) 1/4" x 1 1/4" drill screws (157630). b) Install "Purlin Brace" to "Mount Purlins" by

BRACKETANGLE

OUTLINE OF RAFTER

BEND BRACKETANGLE MOUNT TO

RAFTER BEND BRACKETANGLE MOUNT TOOUTLINE OF RAFTER

RAFTER

3X6 TUBE TO RAFTER

BEND BRACKETANGLE MOUNT TO

OUTLINE OF RAFTER

HEADER TO TOWER

TOWER

3X6 TUBE TO TOWER

12

Page 14: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

BRACKET

1907673x3x7'

DOOR POST

FOR WALK-IN DOORLOCATION AND WIDTHNEEDED FOR DESIREDOF END WALL WHERE

(172249)MOUNTANGLEBRACKET

MOUNTPER BRACKET ANGLESCREWS (157630)(8) 1/4" X 1 1/4" DRILL

TRIM BOTTOM TUBE

IN DOORHEIGHT FOR WALK-TUBE TO REQUIRED

END WALL HORZIONTAL

(172249)MOUNTANGLEBRACKET

(172249)MOUNTANGLE

BRACKET

(172249)MOUNTANGLE

DOOR POST3x3x7'190767

ADJUST EXISITNG

1/2" ANCHORS, WASHERS,& NUTS (CUSTOMER SUPPLIED)TO MOUNT WALK-IN DOORTOWERS TO FOUNDATION

IS ADJUSTABLEDOOR WIDTH

WALK IN DOOR FRAMING (OPTIONAL)

Note: Walk-in door option only applicable if ordered.

INSTALLATION INSTRUCTIONS

Install walk-in door where desired and as shown below.

13

Page 15: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

38

1

TO FOUNDATIONFOR SECURING TOWERS

3

3

3 3

3

2

2

2

1

1

3

1

3

3 33

3

3

3

3

3

3

3

3

3

333

6 6

77

8

9

9 9

910

10

3

3

3

3

2

REFER TO STEP 2 (PG 11)

3

9'-6"16'-4"9'-6"

9'-0"

18'-4" 16'-4"

3 1/2"

BEND TO3

OUTLINEOF RAFTER

CUT TUBE TOOUTLINE OF

RAFTER

3

FOR INSTALLING BRACKETREFER TO STEP 5 (PG 12)

3

3

ANGLE MOUNTS3

4

CENTER

4

70' SENTRY SOLID END WALL W/PW LEG

4

REFER TO PART LIST ON PAGE 6 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

5

5

54

RAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4 4 4

4

2

11-12) FOR INSTALLING

54

TOWERS & PURLINS

REFER TO STEP 3 & 4 (PGS

1

14

Page 16: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

2

3 32X

TO FOUNDATIONFOR SECURING TOWERS

2

3

2

2

3

3

1

1

1

1

3

3 3

3

3

3

3

3

3

3

3

3

33

6 6

77

8

9

9 9

91010

3

3

3REFER TO STEP 2 (PG 11)

HEADER HEIGHTIS ADJUSTABLE

2X

16'-4"9'-6"

9'-0"

18'-4" 16'-4" 9'-6"

3 1/2"

18'-0"

54

1

TOWERS & PURLINS11-12) FOR INSTALLING

REFER TO STEP 3 & 4 (PGS

2

OUTLINEOF RAFTER

BEND TO3

CUT TUBE TOOUTLINE OF

RAFTER

4 RAFTER4

70' SENTRY 18' DOOR END WALL W/PW LEG

4

REFER TO PART LIST ON PAGE 6 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

5

5

5

CENTER4RAFTER

END

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

4

4

3

3

REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET

ANGLE MOUNTS

15

Page 17: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

70' SENTRY 2-16' DOORS END WALL W/PW LEG

4

4

REFER TO PART LIST ON PAGE 6 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

5

5

5

CENTERRAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

4

4

4

4

3

8

FOR SECURING TOWERSTO FOUNDATION

3

3

2

2

2

2

31

1

1

3

3 33

3

3

3

3

6

IS ADJUSTABLEHEADER HEIGHT

2X

1

77

9

8

6

1010

3

3

33

3

2X

HEADER HEIGHTIS ADJUSTABLE

2X

REFER TO STEP 2 (PG 11)

9

2X

18'-4"

16'-0"

16'-4"

16'-0"

9'-6"9'-6"

9'-6"

16'-4"

3 1/2"

1

TOWERS & PURLINS

54

REFER TO STEP 3 & 4 (PGS11-12) FOR INSTALLING

2

3

REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET

ANGLE MOUNTS

BEND TO

OF RAFTEROUTLINE

3

CUT TUBE TOOUTLINE OF

RAFTER

16

Page 18: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

2

TOWERS & PURLINS11-12) FOR INSTALLING

54

REFER TO STEP 3 & 4 (PGS

1

FOR INSTALLING BRACKETANGLE MOUNTS

REFER TO STEP 5 (PG 12)

33

3

3

BEND TO3

OF RAFTEROUTLINE

CUT TUBE TOOUTLINE OF

RAFTER

70' SENTRY SOLID END WALL W/6' LEG

4

NUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.REFER TO PART LIST ON PAGE 7 OF THIS MANUAL FOR ITEM

5

5

5

5

RAFTERCENTER

RAFTER

ITEM 5 PART # IS

ENDBAY SPACING

DEPENDENT ON

4

4

4

4

4

4 4

3

2

TO FOUNDATIONFOR SECURING TOWERS

3

3

33

2

2

2

REFER TO STEP 2 (PG 11)

1

1

1

1

3

3 33

3

3

3

3

3

3

3

33

333

66 88

9

10

10 10

1011

11

3

3

3

3

3

3

9

7 7

3

REFER TO STEP 1 (PG11)FOR SECURING TOWERSTOGETHER

9'-6"

12'-3"

18'-4" 16'-4"16'-4"

3 1/2"

9'-6"

17

Page 19: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

3

8

FOR SECURING TOWERSTO FOUNDATION

3

3

2

2

2

2

1

1

1

1

3

3 3

3

3

3

3

3

3

3

33

33

6

7 99

10

11

1111

1112

12

3

3

3

3

3

8TOGETHERFOR SECURING TOWERS

2X

REFER TO STEP 2 (PG 11)

REFER TO STEP 1 (PG11)

HEADER HEIGHTIS ADJUSTABLE

2X

9'-6"

12'-3"

18'-4" 16'-4"16'-4"

3 1/2"

9'-6"

18'-0"

4

70' SENTRY 18' DOOR END WALL W/6' LEG

4

REFER TO PART LIST ON PAGE 7 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

5

5

5

CENTERRAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

4

4

4

4

3

ANGLE MOUNTSFOR INSTALLING BRACKETREFER TO STEP 5 (PG 12)

3BEND TO

OF RAFTEROUTLINE

3

CUT TUBE TOOUTLINE OF

RAFTER

1

TOWERS & PURLINS11-12) FOR INSTALLING

54

REFER TO STEP 3 & 4 (PGS

2

18

Page 20: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

1

TOWERS & PURLINS11-12) FOR INSTALLING

54

REFER TO STEP 3 & 4 (PGS

2

70' SENTRY 2-16' DOORS END WALL W/6' LEG

4

4

REFER TO PART LIST ON PAGE 7 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

5

5

5

CENTERRAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

4

4

4

4

3

3

REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET

ANGLE MOUNTS

BEND TO

OF RAFTEROUTLINE

3

CUT TUBE TOOUTLINE OF

RAFTER2X

2X

8

2

FOR SECURING TOWERSTO FOUNDATION

3

3

33

2

10

IS ADJUSTABLEHEADER HEIGHT

2X

2

1

1

1

1 3

3 33

3

3

3

3

7 6 99

11

210

1212

3

3

3

3

11

8

REFER TO STEP 2 (PG 11)

FOR SECURING TOWERSTOGETHER

REFER TO STEP 1 (PG 11)

HEADER HEIGHTIS ADJUSTABLE

2X

16'-0" 12'-3"

18'-4" 16'-4"16'-4"9'-6" 9'-6"

3"16'-0"

19

Page 21: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

4

REFER TO STEP 3 & 4 (PGS

TOWERS & PURLINS11-12) FOR I NSTALLING

5

2

1BEND TO

3OF RAFTER

OUTLINE

CUT TUBE TOOUTLINE OF

RAFTER

3

33

REFER TO STEP 5 (PG 12)

ANGLE MOUNTSON MOUNTING BRACKET

3

5

70' SENTRY SOLID END WALL W/8' LEGNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.REFER TO PART LIST ON PAGE 8 OF THIS MANUAL FOR ITEM

45

5

5

RAFTERCENTER

RAFTER

ITEM 5 PART # IS

ENDBAY SPACINGDEPENDENT ON

4

4

4 44

4 4

2

TO FOUNDATIONFOR SECURING TOWERS

3

3

33

2

2

3

REFER TO STEP 2 (PG 11)

2

1

1

1

1

3

3 33

3

3

3

3

3

3

3

33

333

66 8

8

9

10

10 10

1011

11

3

3

3

3

3

3

9

7 7

3

REFER TO STEP 1 (PG11)FOR SECURING TOWERSTOGETHER

9'-6"

13'-3"

18'-4" 16'-4"16'-4"

4"

9'-6"20

Page 22: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

4

70' SENTRY 18' DOOR END WALL W/8' LEG

4

REFER TO PART LIST ON PAGE 8 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

5

5

5

CENTERRAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

4

4

4

4

BEND TO

OF RAFTEROUTLINE 3

CUT TUBE TOOUTLINE OF

RAFTER

3

ANGLE MOUNTSFOR INSTALLING BRACKETREFER TO STEP 5 (PG 12)

3

3

2

FOR SECURING TOWERSTO FOUNDATION

3

3

2

8

2

2

1

1

1

1

3

3

TOGETHERFOR SECURING TOWERS

2X3

3

3

3

3

3

3

33

33

6 799

10

11

1111

1112

12

3

3

3

3

3

3

8

REFER TO STEP 2 (PG 11)

REFER TO STEP 1 (PG11)

HEADER HEIGHTIS ADJUSTABLE

2X

18'-0"

3 1/2"

9'-6"

13'-3"

18'-4" 16'-4"16'-4" 9'-6"

1

TOWERS & PURLINS11-12) FOR INSTALLING

54

REFER TO STEP 3 & 4 (PGS

2

21

Page 23: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

1

TOWERS & PURLINS11-12) FOR INSTALLING

54

REFER TO STEP 3 & 4 (PGS

2

2X2X

8

2

FOR SECURING TOWERSTO FOUNDATION

3

3

33

2

2

2

3

1

1

1

IS ADJUSTABLEHEADER HEIGHT

2X

3

3 33

3

3

3

3

7 699

11

12

10

12

TOGETHERFOR SECURING TOWERS

3

10 3

3

11

8

REFER TO STEP 2 (PG 11)

1

REFER TO STEP 1 (PG 11)

HEADER HEIGHTIS ADJUSTABLE

2X

16'-0"

9'-6"

16'-0"

18'-4" 16'-4"16'-4"

13'-3"

3"

9'-6"

5

4

70' SENTRY 2-16' DOORS END WALL W/8' LEG REFER TO PART LIST ON PAGE 8 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

45

5

CENTERRAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

4

4

4

4

BEND TO

OF RAFTEROUTLINE 3

CUT TUBE TOOUTLINE OF

RAFTER

3

3

REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET

ANGLE MOUNTS

22

Page 24: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

BEND TO

OF RAFTEROUTLINE

3

CUT TUBE TOOUTLINE OF

RAFTER

ANGLE MOUNTS

3

REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET

3

3

3

70' SENTRY SOLID END WALL W/10' LEG

44

4

4

54

REFER TO PART LIST ON PAGE 9 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

4

5

5

CENTERRAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

2

TOWERS & PURLINS11-12) FOR INSTALLING

54

REFER TO STEP 3 & 4 (PGS

1

3

9

77

3

3

REFER TO STEP 2 (PG 11)FOR SECURING TOWERSTO FOUNDATION

3

3

33

2

22

8

1

1

1

1

3

3 33

3

3 3

3

3

3

3

33

333

66

8

2

9

10

10 10

1011

11

3

3

3

3

3

REFER TO STEP 1 (PG11)FOR SECURING TOWERSTOGETHER

14'-3"

9'-6" 18'-4" 16'-4"16'-4"

3 1/2"

9'-6"

23

Page 25: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

FOR SECURING TOWERS2

TO FOUNDATIONFOR SECURING TOWERS 3

3

2

2X2

2

1

1

1

1

3

3 3

3

3

3

3

3

3

3

33

33

6 7 99

10

11

1111

1112

12

3

3

3

3

3

8

8

3

REFER TO STEP 2 (PG 11)

TOGETHER

REFER TO STEP 1 (PG11)

HEADER HEIGHTIS ADJUSTABLE

2X

9'-6"

14'-3"

18'-4" 16'-4"16'-4"

3 1/2"

18'-0"

9'-6"

REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET

ANGLE MOUNTS

3

3

BEND TO 3

OF RAFTEROUTLINE

CUT TUBE TOOUTLINE OF

RAFTER

1

TOWERS & PURLINS11-12) FOR INSTALLING

54

REFER TO STEP 3 & 4 (PGS

2

70' SENTRY 18' DOOR END WALL W/10' LEG

4

NUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.REFER TO PART LIST ON PAGE 9 OF THIS MANUAL FOR ITEM

5

5

5

5

RAFTERCENTER

RAFTER

ITEM 5 PART # IS

ENDBAY SPACING

DEPENDENT ON

4

4

4

4

4

4 4

24

Page 26: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

2X2X

HEADER HEIGHT

8

10

IS ADJUSTABLEHEADER HEIGHT

3

3

33

2

TO FOUNDATIONFOR SECURING TOWERS

2

2

1

1

1

1

3

3 33

3

3

3

7 6

99

11

2

10

1212

3

3

3

3

11

8

REFER TO STEP 2 (PG 11)

FOR SECURING TOWERSTOGETHER

IS ADJUSTABLE

2XREFER TO STEP 1 (PG 11)

32X

16'-0"

9'-6"

16'-0"

18'-4" 16'-4"16'-4"

14'-3"

3 1/2"

9'-6"

4

70' SENTRY 2-16' DOORS END WALL W/10' LEG

4

REFER TO PART LIST ON PAGE 9 OF THIS MANUAL FOR ITEMNUMBERS, PART NUMBERS, DESCRIPTIONS, & QUANTITIES.

5

5

5

5

CENTERRAFTER

RAFTEREND

ITEM 5 PART # ISDEPENDENT ON

BAY SPACING

4

4

4

4

4

4

4

TOWERS & PURLINS11-12) FOR INSTALLING

5

1

REFER TO STEP 3 & 4 (PGS

2BEND TO

OF RAFTEROUTLINE

3

CUT TUBE TOOUTLINE OF

RAFTER

3

3

REFER TO STEP 5 (PG 12)FOR INSTALLING BRACKET

ANGLE MOUNTS

25

Page 27: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

MAINTENANCE SCHEDULE

1. One Week Inspection a. The key visual indicator of adequate tension in the building fabric cover and end wall

panel is to ensure all creases and wrinkles in the fabric are removed. Check the ratchet straps for tightness and adjust as necessary. Refer to step 9 of cover installation manual for recommended torque settings for 1" and 2" ratchets.

b. Punctures in the fabric cover caused by accidental damage should be repaired

immediately. The fabric requires a product specific heat seam weld repair. Contact your local Sioux Steel Pro-Tec® building dealer or manufacturer to schedule service.

c. Ensure all tension cables are taut. Cables should not sag. Adjust turnbuckles as

necessary.

2. Installation Adjustment a. The building and end wall panels cover on your SIOUX PRO-TEC® Sentry Building

may relax after installation. It is critical to keep the cover taut (snug) over the rafters and end wall panels taut over end wall framing to prevent wear and ensure a long life. Tighten ratchets and adjust cables as required.

3. Annual Maintenance

a. Repeat 1 Week Inspection (listed above) a minimum of (4) times a year. b. Visually inspect each cross cable for signs of wear and check turnbuckle tension.

Replace and/ or tighten as necessary. c. Check all base plate anchor studs and nuts to assure they are tight. d. Check all ratchet mount and winch bolts and nuts to assure they are tight. e. Check for premature wear of fabric cover, especially where tension is applied and where

there is direct contact with the buildings steel frame. f. Check for premature deterioration of the corrosion protection on the building components.

NOTE: Building covers and end wall panels installed in cooler weather may relax more than covers installed in warm weather. Check tight ness on covers and end wall panels installed in cooler weather on the first available sunny day and adjust cables as necessary. Severe weather conditions may also affe ct your cover, check cover after such conditions occur.

NOTE: Failure to carry out above steps will invalid ate the warranty. WARNING: FLAMMABLE MATERIAL EXPOSURE TO ANY HEAT SOURCE FOR ANY LENGTH OF TIME COULD RESULT IN DAMAGE TO THE FABRIC COVER OR END PANEL MATERIAL. EXHAUST GA SES, SPACE HEATER, WELDING SPARKS, ETC. SHOULD NOT BE ALLOWED TO GET NEAR THE FABRIC PORTION OF STRUCTURE. SIOUX STEEL COMPANY WILL NOT BE RESPONS IBLE FOR ANY DAMAGES OR LIABILITIES RESULTING FROM FAILURE TO HEED THIS WAR NING. THE COVER OR END PANEL MATERIAL STARTS TO DETERIORATE AT EXPOSURE TO 180° TEMPERATURE FOR ANY LENGTH OF TIME. PREVENT PROLONGED CONTACT FROM ANY HEAT SOURCE TO ENSURE MAXIMUM PROTECTION TO THIS MATERIAL. FOR ANY FURTH ER INFORMATION CONTACT SIOUX STEEL COMPANY.

Page 28: END WALL MANUAL - d3otus7o5uizil.cloudfront.net

Revised 07/14/2017

NEW PRODUCT WARRANTY PRO-TEC BUILDINGS

LIMITED WARRANTY FOR NEW SIOUX STEEL COMPANY PRODUCTS A. GENERAL PROVISIONS . “Sioux Steel” means Sioux Steel Company, 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104. The warranties described below are provided by Sioux Steel to the original purchasers of new products purchased from Sioux Steel or from an authorized Sioux Steel Dealer (the “Products”). Under these warranties, Sioux Steel will, at its option, repair or replace at its factory any Product covered under these warranties which is found to be defective in material and workmanship during the applicable warranty term or refund the purchase price paid for the defective Product. Customer will be responsible for labor charges for removing the defective Product and reinstalling the repaired or replacement Product, any premium charge for overtime labor requested of Sioux Steel and shipping charges to and from Sioux Steel’s factory. These warranties are not transferrable . B. WARRANTY PERIOD . Subject to exclusions and limitations set forth herein, each new Product is warranted for the number of years specified below. Each warranty term begins from the date of purchase regardless of delay in receipt of the Product by Customer due to the time required to process, handle, ship, assemble, construct and install the Product. Customer must retain proof of the date of purchase. Replacement parts for and repairs to the Product will be warranted only for the remainder of the original warranty term. The replacement parts for or repairs to the Product will not extend the warranty term beyond the original warranty term. Products described below include all parts, components and accessories.

PROTEC BUILDINGS Pro-Tec Poultry Buildings 1 Year Safeguard Livestock Shade 1 Year Pro-Tec Single Tube (24’, 30’, and 36’) Buildings 3 Years All Other Powder-Coated Pro-Tec Buildings in Livestock (other than Poultry) and Chemical Storage Applications 7 Years, Prorated Monthly All Other Powder-Coated Pro-Tec Buildings Except those in Livestock and Chemical Storage Applications 15 Years, Prorated Monthly All Other Hot-Dip Galvanized Pro-Tec Buildings 15 Years, Prorated Monthly Fabricated Tarp Materials (covers) 15 Years, Prorated Monthly Fabricated Tarp Materials for End Panels (All Pro-Tec Buildings) ; Rollup Sides; Curtains and Doors; Track Doors; Quarter Panels and Half Moon End Panels ( On all Building Models)

3 Years, Prorated Monthly

Proration credit will be given toward the purchase price for the replacement of fabric and tarp materials, based on Sioux Steel’s current price list at the time the warranty claim is made.

15 Year Proration Schedule: 7 Year Proration Schedule: Year 1 = 93% Year 4 – 73% Year 7 – 53% Year 10 = 33% Year 13 = 13% Year 1 = 86% Year 4 = 43% Year 7 = 0% Year 2 = 87% Year 5 = 67% Year 8 = 47% Year 11 = 27% Year 14 = 7% Year 2 = 72% Year 5 = 29% Year 3 = 80% Year 6 = 60% Year 9 = 40% year 12 = 20% Year 15 = 0% Year 3 = 58% Year 6 = 15%

Exclusions specific to Pro-Tec Buildings: Damage or loss of any kind from (1) exposure of the fabric cover or end panel material to any heat source for any length of time; (2) a failure to properly compact and engineer soils; (3) a failure to properly construct footings and foundations; and (4) exposure to conditions in excess of the design wind and snow load specifications. NOTICE: Caustic and corrosive environments can resu lt from live animal operations or storage of caustic materials. Sioux Steel reserves the right to exclude from warranty under D(4) if co nditions are deemed by it as extreme. C. ITEMS COVERED SEPARATELY . The Sioux Steel warranties do not cover any parts, components or materials that are part of the Product, or used in conjunction with the Product, that are not manufactured by Sioux Steel. Such parts, components and materials will be subject to the warranties provided by the manufacturer, if any. D. WHAT IS NOT WARRANTED . Sioux Steel does not warrant and is not responsible for the following: (1) used products; (2) modification or alteration of the Products; (3) Products that have not been properly installed or not installed in accordance with the instruction manual, improper assembly, or improper construction by any persons other than Sioux Steel employees; (4) depreciation, damage or loss caused by the use of parts, components or accessories not provided by Sioux Steel, unauthorized repairs, normal wear, lack of necessary and proper maintenance, a failure to follow operating instructions/recommendations, misuse, lack of proper protection during storage, vandalism or theft, exposure to the elements or corrosive materials, accidents or acts of nature including lightning, flooding, hail, straight winds and tornadoes; and (5) cosmetic damage or damage that does not hinder the functionality of the Products. E. LIMITATIONS OF WARRANTIES AND CUSTOMER’S REMEDI ES. To the extent permitted by law, neither Sioux Steel, the Dealer nor any person or company affiliated with either of them makes any warranties, representations, conditions or promises express or implied as to the quality, performance or freedom from defects of the Products covered by these warranties other than those set forth herein. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NEITHER SIOUX STEEL, THE DEALER, NOR ANY PERSON OR COMPANY AFFILIATED WITH EITHER OF THEM WILL BE LIABLE FOR ANY DAMAGES, INCLUDING, BUT NOT LIMITED TO, INCIDENTAL, SPECIAL, EXEMPLARY, CONSEQUENTIAL, LOST PROFITS AND REVENUES, LOST USE OF THE PRODUCTS OR ANY OTHER PROPERTY, BODILY INJURY OR PROPERTY DAMAGE CLAIMS OF ANY PERSON, LOST COMMODITIES, REMOVAL OR STORAGE COSTS FOR THE PRODUCTS, OTHER EQUIPMENT AND COMMODITIES, DAMAGE TO THE ENVIRONMENT ARISING FROM OR IN ANY MANNER RELATED TO ANY RELEASE OF HAZARDOUS MATERIALS, AND REMEDIATION EXPENSES THEREFORE, WHETHER BASED ON CONTRACT, TORT, STRICT LIABILITY OR ANY OTHER LEGAL BASIS, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO INSTANCE WILL SIOUX STEEL, THE DEALER OR ANY PERSON OR COMPANY AFFILIATED WITH EITHER OF THEM BE LIABLE TO CUSTOMER OR ANY PERSON IN AN AMOUNT IN EXCESS OF THE PURCHASE PRICE PAID BY CUSTOMER FOR THE PRODUCT. F. NO DEALER WARRANTY . THE DEALER HAS NO AUTHORITY TO MAKE ANY WARRANTY, REPRESENTATION, CONDITION OR PROMISE ON BEHALF OF SIOUX STEEL, OR TO MODIFY THE TERMS OR LIMITATIONS OF THIS WARRANTY IN ANY WAY. G. GOVERNING LAW/VENUE . These warranties, and all terms set forth herein, are governed by the laws of the State of South Dakota and, where applicable, the laws of the United States of America. Any and all disputes arising from these warranties, the purchase and use of the Products, bodily injury and property damage claims or otherwise must be venued in the South Dakota Circuit Court sitting in Minnehaha County, South Dakota. Customer agrees to such venue and waives any challenge to such court’s jurisdiction based upon lack of personal jurisdiction or inconvenience. H. SECURING WARRANTY SERVICE . In order to receive warranty services, customer must give Sioux Steel written notice of a warranty claim within 3 days of the date of discovery of the defective materials or workmanship, and Customer must complete the following steps:

(1) Obtain from Sioux Steel a Return Goods Authorization Number (“RMA Number”) by calling the Customer Service Department at 1-800-557-4689, and providing the following information:

� An explanation as to why the Product is being returned. � The name of the territory representative, Dealer or Sioux Steel salesperson from whom the Product was

purchased. � The Dealer’s identification number. � The invoice number and date of purchase. � Customer’s name, phone number, fax number, mailing address and email address. � The date that the Product will be returned.

(2) Pay the shipping charges to ship the Product to Sioux Steel’s factory, and the return shipping charges. (3) Ship the Product to Sioux Steel at 196 1/2 East Sixth Street, Sioux Falls, South Dakota 57104.


Recommended