Energy Efficiency Fan
Transcript
Page 1: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Energy Efficiency Fan

Page 2: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Technical Know-how

• Scientists from Aerospace Engineering have been involved in the Aerodynamic design development of our FRP Fans

• National Aeronautical Laboratory & Hindustan Aeronautical Laboratory were involved in structural design of the FRP blades

• Prof. Mr. A.K. Rao Technical consultant to Lockheed of U.S.A. With his group from Indian Institute of Science Bangalore is behind the success of FRP Fans

Page 3: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Design Criteria

Performance : By Optimizing Fan dia. & no. of Blades

Efficiency : By Lower H.P.

ղ = Q x TP1,000 x KW

Q = Airflow (M3 / Second)

TP = Total pressure (Pascal)

ղ = Fan efficiency

E & C Resistance : Selection of High-Grade FRP

UV Degradation (Epoxy Resin) Composites

Vibration : Higher dampening property

Noise : Lower level (< 85 dbA)

Page 4: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Analysis of Power Consumption in Axial Flow Fans

KW at Fan Shaft = Q x TP = FKW

3.68 x 105 x ղf

Q = Airflow (M3/Hr.)

TP = Total pressure (Pascal)

ղ = Fan efficiency

If ղT = Transmission efficiency

KW at Motor Shaft = FKW/ ղT = MKW

If ղM = Motor efficiency

MKW to Motor = MKW/ ղM

Page 5: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Factors Affecting Fan Performance

Design of BladeAirfoil sectionProfile of blade at difference radii & staggeringChord length at difference radiiThickness and CamberBlade twistAngle of attack

Design of HubMinimum Air Cycling loss

No. of BladesAir volume & Pressure requirement

Fan RPMFor tip speed along with Noise & Vibration Criteria

Page 6: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Factors Affecting Fan Performance

1) Fans Design

2) Deteriorated Factor

3) Friction Loss

4) Weight of Fans

: 70 %

: 15 %

: 10 %

: 5 %

Page 7: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

• Reduction of that surface while maintaining the shape and effect of an Airfoil was investigated. The solution was found in an Airfoil shaped extra surface available to trim at the blade tip, which follows the spherical line of the profile as shown in figure.

• The change in the pressure distribution by the modification with the Aerospan is remarkable. The pulse caused by the surface velocity pressure of the blade tip has been minimized.

Aerospan

Page 8: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Pressure Zone on the Airfoil

• Faster airflow causes a decrease in air pressure.

• Air Flowing over the curved upper surface if wing speeds up

• Increase in speed reduced pressure above the wing and produces the upward lifting force

Page 9: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...
Page 10: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Performance Curve

Page 11: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Criteria for Material Selection

• Corrosion resistance

• Higher Efficiency due to improved

• Aerodynamics characteristics

• Structural Integrity

• High strength to Weight ratio

• General adaptability to complex Geometries

Page 12: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Choice of Resins

• Epoxy Resin

• Superior mechanical strength• Greater chemical resistance• Lower water absorption• Higher heat resistance• High dynamic strength• High fatigue strength• Better surface finish

• Polyester (GRP)

• Cheaper quality standard• Weak resin structure• High Water absorption

EKOSMART

Selection

Page 13: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Properties Comparison of EKOSMART FRP with Epoxy Blades & Steel Blades

Properties Unit ENCON FRP with

Epoxy Fans Blades

Steel Blades

Ultimate Tensile Strength Kg/cm2 4,000 – 8,000 2,038

Tensile Modulus Kg/cm2 2.5 – 4.8 x 105 21.4 x 105

Flexural Strength Kg/cm2 2,500 – 10,000 1,940

Flexural Modulus Kg/cm2 3 – 5 x 105 21.4 x 105

Compressive Strength Kg/cm2 2,500 – 5,000 1,900

Specific Gravity - 1.8 - 2 7.8

Page 14: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

EKOSMART Product Range

Fan diameter 2 ft – 50 ft

No. of Blades 2 – 22

Air Flow Up to 1,800 M3/sec

Pressure Up to 1,400 Pascal

Speed 81 – 3,000 RPM

Power rating 0.5 – 270 HP

Operating

temperature

-10 0C – 230 0C

Page 15: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Standard Material of Construction

Material of Construction

Blades

Fibre Glass Reinforced Plastic

with High Grade Epoxy Resin

Hub Assemblies

CS HDG/CI Alloy

Aluminium Alloy LM-4/LM-6

SS 304

SS 316

SS 316L

Page 16: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Fan Materials1) FRP (Vetrotex)

2) Epoxy (Huntsman)

3) Anti-Corrosion Epoxy Paint

4) Extra Coating (Erosion & UV

preventing)

Productionby Pressure Bag Molding

Page 17: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Application Areas of EKOSMART

1) Cooling Tower

2) Air Cooled Heat Exchanger

3) Air Cooled Condensers

4) Humidifier

5) Air Washer

6) Mines & Ventilation

1) Radiator Engines

2) Dryers

3) Kiln Shell

4) Industrial Ventilation & Exhaust

5) Man Cooler

Page 18: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Application Areas of EKOSMART

Factories

Petroleum Refining

Petrochemical

Power Generation

Gas Processing

Textile

Cement

Pulp & Paper

Steel & Metal

Foods

Chemicals Etc.

Building

High Rise Building

Hotel

Hospital

Department Store

Page 19: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Application : Cooling TowerFan Dia. : 1 ft. – 50 ft.

No. of Blades : 4 - 12

Air Flow Range : 10 m3/sec – 1,200 m3/sec

Total Pressure : 50 – 250 Pascal

Efficiency : 84% - 90%

RPM : 54 – 540 RPM

Page 20: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Application : Air Cooled CondenserFan Dia. : 1 ft – 40 ft.

No. of Blades : 4 - 12

Air Flow Range : 10 m3/sec – 1,200 m3/sec

Total Pressure : 50 – 250 Pascals

Efficiency : 84% - 90%

RPM : 54 – 540 RPM

Page 21: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Application : MinesFan Dia. : 2 ft. – 16ft.

No. of Blades : 4 – 24 (Even)

Air Flow Range : 5 – 500 m3/sec

Total Pressure : 5 – 1400 Pascal

Efficiency : 81% - 90%

RPM : 300 – 3000 RPM

Page 22: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Application : Withering ThroughFan Dia. : 2 ft. – 6 ft.

No. of Blades : 4 - 8

Air Flow Range : 3 m3/sec – 30 m3/sec

Total Pressure : 50 – 250 Pascal

Efficiency : 81% - 90%

RPM : 1000 – 1500 RPM

Page 23: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Application : Air WasherFan Dia. : 1 ft. – 7 ft.

No. of Blades : 4 - 12

Air Flow Range : 5 m3/sec – 50 m3/sec

Total Pressure : 50 – 900 Pascal

Efficiency : 81% - 90%

RPM : 550 – 3000 RPM

Page 24: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Distinctive Benefits

Guaranteed max. efficiency

Greater Economy

Aerodynamic designed

Higher lift to drag ratio

Negligible skin friction

Short Pay back period

Low noise level

Trouble freeMaintenance free

And many more

Tuflite & Sturdy

Superior duty condition

Page 25: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Difference between EKOSMART FRP Fans & Aluminium

No Items E- Glass Epoxy ENCON Fans Aluminum/GRP/FRP

1 Efficiency 81% - 90% 56% – 65%

2 Design Aerodynamic High Profile Old conventional

3 Material High Grade Epoxy (CIBA -USA)

laminated with FRP (Vetrotex -

France)

Aluminium Casting

4 Blade Hollow Blade (Less Weight) Solid Blade (More Weight)

5 Axial Low Axial thrust on Gear Box High Axial thrust on Gear Box

6 Energy Saving

Guarantee

20% + for Energy Saving

Guarantee

Energy Saving is Nil

7 Endurance Life > 10 years Aging effect after 2 - 3 years

Page 26: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Difference between EKOSMART FRP Fans & Aluminium

No Items E- Glass Epoxy ENCON Fans Aluminum/GRP/FRP

8 Skin Friction Negligible skin friction More Drag losses due to rough

surface

9 Heat Distortion

Resistance

High , due to Epoxy Base Material N.A.

10 Maintenance Cost Zero Maintenance prone

11 Leading Edge

Protection

Provided with extra re-inforcement

of Epoxy resin

High deteriorates

12 Degradation Protected from Erosion, Corrosion,

UV degradation & Abrasion

resistance

High

13 Fan replacement Only individual blade to be replaced Discarding Pair of blade

Page 27: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

EKOSMART Fans Advantages

ENERGY SAVING :

- Lower H.P. motor can be used after installation of EKOSMART fan.

REDUCTION IN THRUST LOAD :

- The thrust load of EKOSMART fan is less than Aluminum blade

- Increase life of Gear Box bearings.

EFFICIENCY :

- Design to achieve minimum 86% efficiency

EASE OF MAINTENANCE:

- EKOSMART Fans are designed for long-free service

- Reduce down time or maintenance power requirement and maintenance cost

BALANCING & VIBRATIONS

- Balance as per ISO standard 1940 (grade 6.3)

- Residual unbalance below 80 mm x gms / kg (micron).

ENVIRONMENT FRIENDLY

- Negligible skin friction due to glossy surface finish

- Fan achieves a low noise level due to Airfoil profile of blades

- More suitable for better ecological peaceful surroundings.

Page 28: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Fan Testing Facilities

EKOSMART Wind Tunnel Test Bench

Electronic Moment Balancing Machine

Dynamic Balancing Machine

Hardness Tester

Cantilever Test Fixture

Coin Tapping Test

Universal Testing Machine

Pendulum Impact Tester

Heat Distortion Test

Muffle Furnace

Anemometer

Sound Level meter

Power Analyzer

Page 31: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

EKOSMART Products Testing

Static Balance Machine

Page 32: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

EKOSMART Products Testing

Loading Testing

Page 33: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Win Tunnel Testing

Page 34: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Quality Assurance

The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard

Raw material are selected out of stringent quality as per ISO/ASTM Standard followed 100% in house process inspection

Guaranteed life of EKOSMART design FRP Fan are normally above 9-14 years operation without any wear & tear and lose of performance

Page 35: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

EKOSMART Products Certificate

• Fans : Static Balance Certificate

• Hubs : Dynamics Balance Certificate

• Products Guarantee Certificate

Page 36: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

PERFORMANCE TEST :

OUR ENGINEER WILL BE CONDUCTING THE ‘ PERFORMANCE TEST’ OF YOUR EXISTING

ALUMINIUM AND OUR FRP FANS IN PRESENCE OF YOUR OFFICIALS AND SHALL BE

MEASURING THE FOLLOWING PARAMETERS :

AIR FLOW

POWER CONSUMPTION AT MOTOR TERMINALS.

BEFORE AFTER

CTI Code CTI Member

Page 37: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Performance Testing Report

Customer Ref. 1

Customer Ref. 2

Customer Ref. 3

We shall provide“Performance Test” of your Existing and

EKOSMART FRP Fans

Page 38: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Return On Investment (ROI)

No Description Aluminum Fan ENCON

Fan

Power

Saving (%)

Increase

Airflow (%)

1 Airflow (CFM) 3,358,783 4,999,023 - 48.83

2 Power (KW) 1,007.4 624.2 38.03 -

Company : Jong Stit Co.,Ltd.,Thailand (Textile)

Application : Air Washer Plant

Q’ty : 114 units

Saving/Year = 3,383.2 KW x 24 Hrs x 360 days= 3,310 MW / Year

Page 39: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

No Description Aluminum Fan ENCON

Fan

Power

Saving (%)

Increase

Airflow (%)

1 Airflow (CFM) 533,186 593,940 - 7

2 Power (KW) 27.26 16.2 40.57 -

Company : TATA Power Co.,Ltd. (Power Plant)

Application : Cooling Tower

Saving/Year = 11.06 KW x 24 Hrs x 360 days

= 95,558.40 KW / Year

Pay Back Period = 2.98 Months

Return On Investment (ROI)

Page 40: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

No Description Aluminum Fan ENCON

Fan

Power

Saving (%)

Increase

Airflow (%)

1 Airflow (CFM) 70,726 84,466 - 19.42

2 Power (KW) 7.1 5.0 29.57 -

Company : Honda Automobiles Co., Ltd. (Automotive)

Application : Cooling Tower

Saving/Year = 2.1 KW x 24 Hrs x 350 days= 17,640 KW Units

Pay Back Period = 7.47 Months

Return On Investment (ROI)

Page 41: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

No Description Aluminum

Fan

ENCON

Fan

Power

Saving (%)

Increase

Airflow (%)

1 Airflow (M3/sec) 836.97 1,024.03 - 22.34

2 Power (KW) 2,219.93 1,408.98 36.53 -

Company : Reliance Industries Co.,Ltd.,(Petrochemical)

Application : Air Fin Coolers

Saving/Year = 810.95 KW x 24 Hrs x 360 days= 7,006,608 KW Units

Pay Back Period = 2.31 Months

Return On Investment (ROI)

Page 42: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

No Description Aluminum Fan ENCON Fan Power

Saving (%)

Increase

Airflow (%)

1 Airflow (CFM) 13,610 14,816 - 8.86

2 Power (KW) 75.39 50.26 33.3 -

Company : Bayer Thai Co.,Ltd., (Polymer)

Application : Cooling Tower

Saving/Year = 25.13 KW x 24 Hrs x 350 days= 211,092 KW Units = 211 MW/year

Pay Back Period = 8.4 Months

Return On Investment (ROI)

Page 43: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

No Description Aluminium

Fan

ENCON

Fan

Power

Saving (%)

Increase

Airflow (%)

1 Airflow (CFM) 81,383 86,278 - 6.01

2 Power (KW) 8.74 6.20 28.14 -

Company : Thai Textile Industry PCL. (Textile)

Application : Cooling Tower

Saving/Year = 2.54 KW x 24 Hrs x 360 days= 21,945 KW Units

Return On Investment (ROI)

Page 44: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Reference CustomerCustomer Name Application Energy Saving (%)

Alkyl Amines Chemicals Limited Cooling Tower 30%

Amines & Plasticizers Limited Cooling Tower 22%

Balasore Alloys Limited Cooling Tower 37.89%

Ballarpur Industries Cooling Tower 25%

Banswapa Syntex Limited Humidification 25%

BASF India Limited Cooling Tower 18% - 20%

Bayer (India) Limited Cooling Tower 20%

Central India Polyesters Ltd. Air Washer 20% - 25%

Century Rayon Cooling Tower 33%

Chennai Petroleum Corporation Ltd. Cooling Tower 25%

Citurgia Biochemicals Limited Cooling Tower 28.31%

DLF Power Limited Cooling Tower approx. 18%

Electrosteel Casting Limited Cooling Tower > 25%

German Remedies Ltd. Cooling Tower 25%

Ginni Filaments Limited Humidification 25%

Gontermann - Peipers (India) Ltd. Air Washer > 15%

GR Grasim Cooling Tower 30%

Grasim Aditya birla Group LTG Plant 18%

GSL (India) Limited Humidification 25%

Gujarat State Fertilizers Co.,Ltd. Cooling Tower 15% - 20%

HEG Limited Humidification 20% - 30%

Hindalco Industries Limited Cooling Tower 30%

Page 45: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Customer Name Application Energy Saving (%)

Indian Petrochemicals Corporation Ltd. Cooling Tower 30%

Indian Rayon and Industries Ltd. Cooling Tower 15% - 20%

Indifil Chemicals Company Cooling Tower 26%

Indo Gulf Fertilisers Ltd. Cooling Tower 25%

Indo Rama Synthetics (I) Ltd. Cooling Tower 27.6%

ITC Limited Air Washer 23.7%

JBF Industries Limited Cooling Tower 25% - 30%

Kanoria Chemicals & Industries Ltd. Cooling Tower 35.5%

Kribhco Shyam Fertilizers Ltd. Air Cooler 25%

Maiher Cement Cooling Tower 25% - 30%

Maruti Udyog Ltd. Air Cooler 25%

Modipon Fibres Company Cooling Tower > 30%

MRF Limited Cooling Tower 25%

Nirion Ltd. Cooling Tower 25%

NSIC Technical Services Center Cooling Tower 20.65%

Orissa Power Generation Corporation Ltd. Cooling Tower 25% - 30%

Pan-Century Edible Oils Sdn. Bhd. Cooling Tower > 25%

Pan Century Oleochemicals Sdn. Bhd Cooling Tower 20% - 25%

Petro Araldite Pvt. Ltd. Cooling Tower 35%

Polychem Limited Cooling Tower 30%

Praxair India Private Ltd. Cooling Tower 30%

P.T. Indo-Bharat Rayon Cooling Tower 30%

Rajashree Syntex Humidification 25% - 38%

Page 46: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Customer Name Application Energy Saving (%)

Renusagar Power Co.,Ltd. Cooling Tower 25%

Sansam Spinners Humidification 30%

Sarabhai M Chemicals Cooling Tower 30%

SATNA Cement Works Cooling Tower 20% - 22%

Shetkari Sahakari Soot Girni Ltd. Cooling Tower 20% - 25%

Shree Digvijay Cement Co.,Ltd. Air Cooler Radiator 33%

Shree Synthetics Limited Cooling Tower 20%

Shruti Synthetics limited Humidification 30%

Standard Mills Co.,Ltd. Humidification 30%

TATA Engineering & Locomotive Co.,Ltd. Cooling Tower 38.8%

TATA Steel Co.,Ltd. Cooling Tower > 30%

Thai Acrylic Fibre Co.,Ltd. Cooling Tower 35%

The Associated Cement Co.,Ltd. Cooling Tower 25%

The Bombay Dyeing & Manufacturing Co.,Ltd. Cooling Tower 20%

The Dawn Mills Co.,Ltd. Humidification > 35%

The Madras Aluminium Co.,Ltd. Cooling Tower 25%

The Ruby Mills Ltd. Air Conditioning 25%

The Mysore Paper Mills Limited Cooling Tower 25% - 35%

Zenith Spinners Ltd. Humidification 20% - 25%

Page 47: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Curves

Page 48: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Required Information for Fans offer

Fan Material & Fan diameter

Fan RPM

Motor power (HP/KW)

Air Flow

Actual power consumption (KW or Amps)

% Energy Saving Guarantee Pay-Back Period Technical Details

EKOSMART will offer

Page 49: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Easy Maintenance

Daily Maintenance

• Check for any unusual noise or vibration

• Check Ammeter for undue fluctuation in the current.

Monthly Maintenance

• Stop the fan & check the fan blades

• Check motor for overheating

• Check all hardware for security/perfect tightening

• Ensure that hole at the blades tip from blockage

• To touch up with suitable paint, whatever required to all exposed parts of steel. Any abnormal condition noticed during the above inspection, the corrosive should be taken up immediately, as required.

Page 50: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Aluminum Fans Dismantling

Page 51: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Aluminum Fans Dismantling

Page 52: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Aluminum Fans Dismantling

Page 53: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Fans Installation

Page 54: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Fans Installation

Page 55: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Fans Installation

Page 56: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Fans Installation

Page 57: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 58: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 59: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 60: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 61: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 62: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 63: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 64: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 65: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 66: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

HONDA Installation

Page 68: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Installation in Cooling Tower

Page 69: Energy Efficiency Fan - EKOSMART · Win Tunnel Testing. Quality Assurance The Aerodynamic performance of FRP Fan can be evaluated in Wind Test Bench as per AMCA 210-8 Standard ...

Installation in Cooling Tower