1 ENGR 512 Experimental Methods in Engineering Spring 2009 Dr. Mustafa Arafa Mechanical Engineering Department [email protected]
Transcript
Page 1: ENGR 512 Experimental Methods in Engineering

1

ENGR 512Experimental Methods in Engineering

Spring 2009Dr. Mustafa Arafa

Mechanical Engineering [email protected]

Page 2: ENGR 512 Experimental Methods in Engineering

2

Outline• PART 1: Principles of measurement

– Instrument types & characteristics• PART 2: Sensors and instruments

– Measurement of common engineering parameters, such as temperature, pressure, flow, force, displacement, strain

– Selection of appropriate instruments• PART 3: Lab session & case studies• References:

– Measurement and Instrumentation Principles, Alan S. Morris, Butterworth-Heinemann, 2001.

– The measurement, instrumentation, and sensors handbook, edited by J.G.Webster, CRC Press, 1999.

Page 3: ENGR 512 Experimental Methods in Engineering

3

Sensors in closed-loop control systems

Page 4: ENGR 512 Experimental Methods in Engineering

4

Types of measurement• Manufacturing measurements

– Discretely monitor product quality• Performance measurements

– Provide performance evaluation as needed• Operational measurements

– Continuously monitor operation process• Control measurements

– Continuously provide feedback signals• Others

– Research-related

Page 5: ENGR 512 Experimental Methods in Engineering

5

Examples

Bogie A (#5)

1A3A9A

6A5A

7A

8A12A

11A

2A4A

10A4B

10B1B3B

9B

2B

11B6B

5B8B

12B

7B

Bogie B (#6)

Accelerometer on traction motor

Accelerometer on axle box

Location of Strain Gauges and Accelerometers for Bogie A (#5) and Bogie B (#6)

NOT TO SCALE

NOT TO SCALE

End beam

Wiring from this side

Wiring from this side

("front" when going towards Marg)("front" when going towards Helwan)

Side beam

Cairo metro, line 1

Page 6: ENGR 512 Experimental Methods in Engineering

6

Essential elements of measurement

Physical behavior Sensor Transducer Signal

conditioner

Data acquisition system

Sensor: responds to physical quantity to be measured Transducer: converts quantity to be measured to an analog signal Signal conditioner: amplify, filter, integrate, differentiate, etc. Data acquisition: records, displays, processes data (hardware &

software)

Measured variable

Variable conversion element

Output display(measurand)

Page 7: ENGR 512 Experimental Methods in Engineering

7

Instrument systems

Humidity sensor

Page 8: ENGR 512 Experimental Methods in Engineering

8

Active and passive instruments

Instrument types

Passive: self powered Active: externally powered

potentiometer

Page 9: ENGR 512 Experimental Methods in Engineering

9

Null-type & deflection-type instrumentsInstrument types

Page 10: ENGR 512 Experimental Methods in Engineering

10

Instrument typesAnalog & digital instruments

Digital: signal can take discrete levelsAnalog: signal is continuous

Page 11: ENGR 512 Experimental Methods in Engineering

11

Static characteristics of instruments

Page 12: ENGR 512 Experimental Methods in Engineering

12

Static characteristics of instruments Accuracy: closeness to correct value Precision: indication of spread of readings

• Repeatability/reproducibility: variation of a set of measurements made in a short/long period of time

Measure of Accuracy

Measure of Precision

Accuracy is often quoted as a % of full-scale (f.s.) reading.Example: pressure gauge, range 0-10 bar with accuracy ±1% f.s.This means ± 0.1 bar, or if you are reading 1 bar, the possible error is 10%.

High accuracy, high precision Low accuracy, high precision Low accuracy, low precision

Bias: need to calibrate

Need to average

Page 13: ENGR 512 Experimental Methods in Engineering

13

Averaging

0 1 2 3 4 5 6 7 8 9 100

0.2

0.4

0.6

0.8

1

1.2

Frequency [Hz]

Acc

eler

atio

n [m

/s2 ]

One Reading

0 1 2 3 4 5 6 7 8 9 100

0.2

0.4

0.6

0.8

1

1.2

Frequency [Hz]

Acc

eler

atio

n [m

/s2 ]

5 Averages

0 1 2 3 4 5 6 7 8 9 100

0.2

0.4

0.6

0.8

1

1.2

Frequency [Hz]

Acc

eler

atio

n [m

/s2 ]

10 Averages

0 1 2 3 4 5 6 7 8 9 100

0.2

0.4

0.6

0.8

1

1.2

Frequency [Hz]

Acc

eler

atio

n [m

/s2 ]

50 Averages

0 1 2 3 4 5 6 7 8 9 100

0.2

0.4

0.6

0.8

1

1.2

Frequency [Hz]

Acc

eler

atio

n [m

/s2 ]

100 Averages

0 1 2 3 4 5 6 7 8 9 100

0.2

0.4

0.6

0.8

1

1.2

Frequency [Hz]

Acc

eler

atio

n [m

/s2 ]

1000 Averages

Page 14: ENGR 512 Experimental Methods in Engineering

14

Static characteristics of instruments

D i

Resolution

Linearity: is the output reading linearly proportional measured quantity? Sensitivity: change in output per unit change in input (slope) Resolution: smallest increment that can be detected

Page 15: ENGR 512 Experimental Methods in Engineering

15

Static characteristics of instruments Sensitivity to disturbance: all calibrations/specifications of an instrument are

only valid under controlled conditions of temperature, pressure, etc. Variation to such environmental changes can lead to

Zero drift (bias) Sensitivity drift

Page 16: ENGR 512 Experimental Methods in Engineering

16

Static characteristics of instruments Example: A spring balance is calibrated in an environment at a temperature of 20°C and has the following deflection-load characteristic.

Load (kg) 0 1 2 3

Deflection (mm) 0 20 40 60

It is then used in an environment at a temperature of 30°C and the following deflection-load characteristic is measured.

Load (kg) 0 1 2 3

Deflection (mm) 5 27 49 71

Determine the zero drift and sensitivity drift per °C change in ambient temperature.

Page 17: ENGR 512 Experimental Methods in Engineering

17

Static characteristics of instruments Hysteresis effects: output reading

depends on whether input quantity is steadily increased or decreased

Dead space: range of input values over which there is no change in output

Page 18: ENGR 512 Experimental Methods in Engineering

18

saturation

Static characteristics of instruments Saturation: no further output, even if input is increased

Page 19: ENGR 512 Experimental Methods in Engineering

19

Dynamic characteristics of instruments

Page 20: ENGR 512 Experimental Methods in Engineering

20

Instrument dynamics governed by the differential equation:

1

1 0 01( ) ( ) ... ( ) ( ) ... ( )n n m

n n mn n m

d d da y t a y t a y t b x t b x tdt dt dt

G(s)x(t)X(s)

y(t)Y(s)

Dynamic characteristics of instruments Static characteristics: steady-state readingsDynamic characteristics: behavior of instrument between the time a measured quantity changes and the time when the instrument oupt attains a steady value in response

Measured quantity Output reading

Page 21: ENGR 512 Experimental Methods in Engineering

21

Zero order instrument: 0 0( ) ( )a y t b x t 0 0( ) ( ) ( )y t b a x t Kx t

Dynamic characteristics of instruments

For a step change in measured quantity, the output moves immediately to a new value. Example: potentiometer

Page 22: ENGR 512 Experimental Methods in Engineering

22

First order instrument: 1 0 0dya a y b xdt

Dynamic characteristics of instruments

Example: liquid-in-glass thermometer

Page 23: ENGR 512 Experimental Methods in Engineering

23

Second order instrument:2

2 1 0 02

d y dya a a y b xdt dt

Dynamic characteristics of instruments

Response can be oscillatory, or damped according to damping ratio.

Page 24: ENGR 512 Experimental Methods in Engineering

24

Errors in measurementErrors in measurement systems:1. Arise during the measurement process

a) Systematic errorsb) Random errors

2. Arise due to later corruption of the signal by induced noiseSystematic error

Random error

Systematic errors: consistently on 1 side of the correct readingSources:1. System disturbance (ex: cold thermometer in hot fluid)2. Environmental changes3. Bent meter needles4. Uncalibrated instruments5. Drift

Random errors: perturbations on either side of true valueSources:1. Human observation of analog meters2. Electrical noise (spurious signals picked up by lead wires)

Page 25: ENGR 512 Experimental Methods in Engineering

25

Errors in measurementOther sources of error:1. Improper sensing position2. Improper data acquisition3. Improper sampling rate

Usually we record a continuous signal y(t) by a set of samples ys(t) at discrete intervals of time Dt.

y(t)

t

yS(t)

t

Dt

The no. of samples recorded each second is defined as the sampling frequency, fS

Page 26: ENGR 512 Experimental Methods in Engineering

26

• If we sampled too slowly, a recorded data will present a distortion from the original signal.

• Over sampling, on the other hand, raises storage issues.

Original signal Sampled data

Errors in measurementUnder sampling of test data

Page 27: ENGR 512 Experimental Methods in Engineering

27

High frequency signal when sampled with a low sampling rate may cause the sampled data to appear to have a lower frequency. This behavior is known as aliasing, and the lower frequency (false) signal is often said to be the alias. To avoid aliasing, the sampling rate must be at least twice the highest frequency in the analog signal.

High frequency signal, sampled with low sampling rate

Errors in measurementAliasing

Page 28: ENGR 512 Experimental Methods in Engineering

28

Strain Measurement

Page 29: ENGR 512 Experimental Methods in Engineering

29

Strain gauges• Strain gauges are devices that experience a change in resistance when they

are stretched or strained• Typical displacements: 0-50 mm• Can be used as parts in other transducers (ex: pressure sensors)• Accuracies within ±0.15% of full-scale are achievable• Manufactured to nominal resistances (most commonly 120W)

Page 30: ENGR 512 Experimental Methods in Engineering

30

Gauge element

Gauge element tab

Solder

Jumper wire

Solder

Lead wiresGauge tab

Sensitive to axial strain

Less sensitive to transverse strain

Strain gauges

Page 31: ENGR 512 Experimental Methods in Engineering

31

Mechanical strain

F F

Base length

Strain: change in length over some specified base length

Extension

Page 32: ENGR 512 Experimental Methods in Engineering

32

LRA

L

Conductor

L

Resistance of a conductor

A

R :Resistance:Resistivity:Length:Area

• Now assume the conductor stretched or compressed.• Resistance will change due to dimensional changes (L,A) AND due

to a fundamental property of materials called piezoeresistance.• Piezoresistance: dependence of on the mechanical strain.

Page 33: ENGR 512 Experimental Methods in Engineering

33

Change in resistance due to strain

2

L LdR d dL dAA A A

LRA

)2

A Ld dL LdAdR

A

Gives: Change in resistance

Longitudinal strain:dLL

L dLTransverse strain: DdDD

For linearly elastic behavior: D

D

R R RdR dA dL dA L

For a small change in R, use Taylor series expansion:

)1 2dR dR

Page 34: ENGR 512 Experimental Methods in Engineering

34

Change in resistance due to strain

/ /GF 1 2 constant/ /

dR R ddL L dL L

• Gauge Factor (GF) is a measure of the sensitivity of the material, i.e. the resistance change per unit applied strain.

• If you know GF, then measurement of allows measurement of the strain .

• This is the principle of the resistance strain gauge

/dR R/dL L

)1 2dR dR

In the absence of a direct resistivity change, 1 2GF For commonly used strain gauges, GF is close to 2.

GF = slope

Change in Resistance with Strain for Various Strain Gage Element Materials

Page 35: ENGR 512 Experimental Methods in Engineering

35

Example

Measurement of strain in a steel beam.

E

For a stress level of 20 MPa and elastic modulus of 200 GPa:

0.0001 100 micro strain

In engineering materials, typical strain levels range from 2 to 10,000 micro strain.

Page 36: ENGR 512 Experimental Methods in Engineering

36

Wheatstone bridge

R1

+-V

R2

R4 R3

Vo

• To convert small changes in resistance to an output voltage, strain gauges are commonly used in bridge circuits.

• Circuit requires DC input or excitation.

V: Bridge excitation

Page 37: ENGR 512 Experimental Methods in Engineering

37

) )1 3 2 4

1 2 3 4o

R R R RV V

R R R R

R1

+-V

R2

R4 R3

Vo

If R1R3=R2R4 Vo=0

Bridge is balanced

• Assume you start with a balanced bridge with R1=R2=R3=R4=R. Then Vo=0.

• Now assume one (or more) of the resistances change by dR1, dR2, dR3 and dR4. The output voltage would then change.

Wheatstone bridge

Page 38: ENGR 512 Experimental Methods in Engineering

38

Electrical resistance strain gauge

R1

+-V

R2

R4 R3

Vo

If we replace only one resistance with an active strain gauge, any changes in resistance will unbalance the bridge and produce a non-zero output voltage.

Quarter bridge configuration (one active gauge)

)14oGFV V

Output is proportional to excitation voltage

Quarter bridge

Page 39: ENGR 512 Experimental Methods in Engineering

39

Other bridge configurations

R1

+-V

R2

R4 R3

Vo

• Half bridge configuration (two active gauges)

• Useful for measuring bending strain in a thin beam or plate.

)1 24oGFV V

2 1

1

2

)12oGFV V

Page 40: ENGR 512 Experimental Methods in Engineering

40

Other strain gauge configurations


Recommended