R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2 - 480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc. shell and tube evaporators ENR 002 - 480 Incorporating
Transcript

R410A RefrigerantAir cooled water chillers with scroll compressors and axial fans, 2.2 - 480kWENR 002-100 models inc. self-cleaning coaxial evaporatorsENR 130-480 models inc. shell and tube evaporators

ENR 002 - 480

Incorporating

1

The complete solution to all your cooling needs

ENR 002 - 480

Index PageGeneral Description ............................................................................................................. 3

Technical features .........................................................................................................................3

Technical Data – ENR Range 002 – 030 ......................................................................... 4

Technical Data – ENR Range 038 – 100 ......................................................................... 5

Technical Data – ENR Range 130 – 480 ......................................................................... 6

Optional Accessories ........................................................................................................... 7

2

3

The complete solution to all your cooling needs

ENR 002 - 480

General DescriptionENR range consists of 28 models covering a cooling capacity from 2.2 to 480kW.

Technical featuresFrameSelf-supporting painted steel frame. Easy to remove panels allow access to the inside of the unit for maintenance and other necessary operations.

CompressorsScroll hermetic type with oil sight glass. Includes an internal overheat protection and crankcase heater, installed on rubber shock absorbers.

EvaporatorSelf-cleaning coaxial type (ENR 002-100) or dual circuit shell and tube (ENR 130-480).

CondenserMade up of a copper tube and aluminium fins. Circuits on the refrigerant side are made to create one circuit in models ENR 002-100 and ENR 005-100 and two independent circuits in models ENR 130-480. Alternative materials are available.

FansAxial fans directly coupled to a three-phase electric motor with external rotor (ENR 002-004 are single phase). A safety fan guard is fitted on the air flow discharge. On the super silenced units the fans have a low rpm.

Electrical BoardIncludes: main switch with door safety interlock, fuses, overload protection for compressors & thermocontacts for fans, interface relays and electrical terminals for external connections. The power supply for ENR 002-004 is 230V/1Ph/50Hz. For all other models, the supply is 400V/3Ph/50Hz.

Refrigeration CircuitAll models include filter dryer. Models ENR 002-004 are capillery, ENR 005+ have thermostatic valves. Models ENR 005+ also include sight glass and liquid line solenoid valve.

Water Circuit:Includes end suction close coupled pump, water tank, flow switch (ENR 002-008 supplied loose), evaporator, temperature sensor, antifreeze probe, water pressure gauge and manual air breather valve.

Microprocessor

A microprocessor controls all the functions of the unit and allows any adjustments to be made. The set-points and operating parameters are set directly into the microprocessor. This type of microprocessor enables the adjustment of up to four compressors. It has a visual alarm signal, push buttons for the various functions, and offers a continuous control of the system as well as saving all the data in case of a cut in the power supply. Through the display, one can input and have an indication of set values.

Principal functionsIndication of entering and leaving water temperature; identification and display of blocks by means of alphanumerical code; control of one or two pumps; differential pressure switch alarm delay at start-up; prestarting of the fans; hour counter of compressors in operation; automatic changeover of compressor and pump sequence; compressors start individually and not together; frost protection; remote on-off; operation signalling; manual operation; manual reset; pump down stop.

AlarmsHigh and low pressure (from 022 model) and overload on each compressor; antifreeze; flow switch (from 022 model); configuration error.

AccessoriesElectronic card for connection to management and service systems; remote display.

Operating RangeCooling

Min. Max.

Inlet water temperature °C 8 25

Outlet water temperature °C 5 20

Water thermal difference °C 3 9

Ambient air temperature °C -20 46

Minimum chilled water outlet temperature with glycol mixture

°C -8

Max. operating pressure heat exchanger water side kPa 1000

4

Incorporating

Technical Data – ENR Range 002 – 030Aircooled liquid chillers ENR series

Scroll compressors R410A

Coaxial evaporator

Condenser with copper tubes, aluminium fin

Axial fans

Model 002 003 004 005 008 010 012 016 018 022 030

Nominal cooling capacity (1) kW 2.2 3.4 4.6 5.3 7.9 10.2 12.2 15.8 18 22.5 31.7Nominal cooling capacity (1) Frig/h 1892 2924 3956 4558 6794 8772 10492 13588 15480 19350 27262Total compressors nominal absorbed power (1) kW 0.8 1.3 1.7 1.7 2.6 3.4 3.9 5.2 5.8 6.7 8.9

COP W/W 2.7 2.6 2.7 3.12 3.04 3.00 3.13 3.04 3.10 3.36 3.56EER W/W 2.4 2.5 2.6 2.9 2.8 2.8 2.7 2.7 2.8 3.0 3.07ESEER 3.4 3.3 3.4 3.3 3.3 3.6 3.8 3.9 3.9 3.8 4.2IPLV 3.9 3.8 3.9 4.1 4.1 4.1 4.3 4.3 4.3 4.5 4.9Compressors no. 1 1 1 1 1 1 1 1 1 1 1Circuits no. 1 1 1 1 1 1 1 1 1 1 1Partion step no. 1 1 1 1 1 1 1 1 1 1 1

Hydraulic Section

Nominal water flow m3/h 0.4 0.6 0.8 0.9 1.4 1.8 2.1 2.7 3.1 3.9 5.5Evaporator pressure drop kPa 22 22 23 23 26 25 27 28 28 31 31Available pressure mca 15 15 15 22 24 26 25 24 24 25 28Pump absorbed power kW 0.15 0.15 0.15 0.37 0.88 0.98 0.98 0.98 0.98 1.28 1.28Pump absorbed current A 1.9 1.9 1.9 3.2 1.7 1.8 1.8 1.8 1.8 2.4 2.4

Hydrulic connections BSP/DN 1/2” 1/2” 1/2” 3/4" 1" 1" 1" 1" 1" 1"

1/41

1/2"Tank volume dm3 40 40 40 40 50 50 50 50 110 110 270

Fan Section

Total air flow m3/h 1400 1300 1500 1500 4700 4700 5900 5700 5700 9100 15600Fans nr. 1 1 1 1 1 1 1 1 1 1 2Fans absorbed power kW 0.10 0.10 0.10 0.10 0.25 0.25 0.68 0.68 0.68 0.81 1.44Fans absorbed current A 0.4 0.4 0.5 0.5 1.1 1.1 3.0 3.0 3.0 1.5 2.8

Total Electric Data

Nominal absorbed power kW 1.2 1.6 2.1 2.2 3.7 4.6 5.6 6.9 7.5 8.8 11.6Maximum absorbed current (F.L.A.) A 8.7 10 10.4 12.5 10.1 10.5 14 14.6 18.8 19.8 26.3Maximum peak current (L.R.A.) A 31 36 35 46 48 48 71 71 75 104 144

Electric feed V/Ph/Hz 230/1/50 400/3/50

Noise Data

Sound pressure (2) dB(A) 51.0 51.0 51.0 51.0 51.0 51.0 52.0 52.0 52.0 52.5 52.3

Dimensions and Weight

Length mm 600 600 600 600 820 820 820 820 1008 1008 1610Width mm 655 655 655 655 615 615 615 615 718 718 860Height mm 1035 1035 1035 1035 1360 1360 1360 1360 1580 1580 1540Weight empty kg 85 85 90 102 175 180 185 190 230 260 390Weight operating kg 125 125 130 145 225 230 235 240 360 390 690

(1) Inlet/Outlet water temperature = +12/+7°C - Condenser air temperature = +35°C; fouling factor = 0 .000043 m²K/W (2) Sound pressure level referred to measures according to normative ISO3744, pressure level at distance of 10 m, referred to free field on reflecting surface

5

The complete solution to all your cooling needs

ENR 002 - 480

Technical Data – ENR Range 038 – 100Aircooled liquid chillers ENR series

Scroll compressors R410A

Coaxial evaporator

Condenser with copper tubes, aluminium fin

Axial fans

Model 038 045 055 061 070 075 090 100

Nominal cooling capacity (1) kW 39 45 52 61 66 78 90 100Nominal cooling capacity (1) Frig/h 33540 38700 44720 52460 56760 67080 77400 86000Total compressors nominal absorbed power (1) kW 11.5 12.9 17.0 17.8 20.5 23.0 25.9 30.7

COP kW/kW 3.39 3.49 3.06 3.43 3.22 3.39 3.47 3.26EER kW/kW 2.97 3.14 2.79 3.00 2.70 2.90 3.02 2.89ESEER 4.4 4.4 4.3 4.2 4.3 4.3 4.2 4.3IPLV 5.1 5.1 5.1 5.0 5.1 5.1 5.1 5.1Compressors no. 1 1 1 2 2 2 2 2Circuits no. 1 1 1 1 1 1 1 1Partion step no. 1 1 1 1/1 1/1 1/1 1/1 1/1

Hydraulic Section

Nominal water flow m3/h 6.7 7.3 8.9 10.5 11.3 13.4 15.5 16.5Evaporator pressure drop kPa 32 32 33 34 33 32 38 39Available pressure mca 31 30 33 32 31 29 28 27Pump absorbed power kW 1.28 2.20 2.57 2.56 2.56 2.56 3.48 3.48Pump absorbed current A 2.4 4.2 4.6 4.6 4.6 4.6 6.1 6.1Hydrulic connections BSP/DN 1 1/2" 1 1/2" 1 1/2" 2" 2" 2" 2" 2"Tank volume dm3 270 270 270 410 410 410 410 410

Fan Section (Axel)

Total air flow m3/h 16800 14800 15600 24800 36000 36000 34000 34000Fans nr. 2 2 2 2 2 2 2 2Fans absorbed power kW 1.62 1.44 1.62 2.50 3.90 3.90 3.90 3.90Fans absorbed current A 3.1 2.8 3.1 5.0 7.8 7.8 7.8 7.8

Total Electric Data

Nominal absorbed power kW 14.4 16.5 21.2 22.9 27.0 29.5 33.3 38.1Maximum absorbed current (F.L.A.) A 31.9 37.8 47.8 51.8 59.9 65.2 75.5 84.4Maximum peak current (L.R.A.) A 160 201 220 173 192 197 242 259Electric feed V/Ph/Hz 400/3/50

Noise Data

Sound pressure (2) dB(A) 53.0 54.8 55.5 55.1 56.2 57.1 57.9 59.5

Dimensions and Weight

Length mm 1610 1610 1610 2220 2220 2220 2220 2220Width mm 860 860 860 1100 1100 1100 1100 1100Height mm 1540 1540 1540 2100 2100 2100 2100 2100Weight empty kg 400 430 450 810 820 830 855 930Weight operating kg 700 730 750 1240 1250 1260 1285 1360

(1) Inlet/Outlet water temperature = +12/+7°C - Condenser air temperature = +35°C; fouling factor = 0 .000043 m²K/W (2) Sound pressure level referred to measures according to normative ISO3744, pressure level at distance of 10 m, referred to free field on reflecting surface

6

Incorporating

Technical Data – ENR Range 130 – 480Aircooled liquid chillers ENR series

Scroll compressors R410A

Shell and tube evaporator

Condenser with copper tubes, aluminium fin

Axial fans

Model 130 160 185 230 280 340 370 430 480

Nominal cooling capacity (1) kW 127 156 184 227 277 340 370 430 480Nominal cooling capacity (1) Frig/h 109220 134160 158240 195220 238220 292400 318200 369800 412800Total compressors nominal absorbed power (1) kW 35.7 46.0 51.8 70.1 77.6 96.0 106.9 127.8 149.5

COP kW/kW 3.56 3.39 3.55 3.24 3.57 3.54 3.46 3.36 3.21EER kW/kW 3.21 3.01 3.19 2.84 3.17 3.22 3.12 3.08 2.98ESEER 4.4 4.3 4.4 4.3 4.2 4.4 4.3 4.3 4.3IPLV 5.2 5.2 5.1 5.1 5.0 5.0 5.1 5.1 5.0Compressors no. 4 4 4 4 4 4 6 6 6Circuits no. 2 2 2 2 2 2 2 2 2Partion step no. 2/2 2/2 2/2 2/2 2/2 2/2 3/2 3/2 3/2

Hydraulic Section

Nominal water flow m3/h 21.8 26.8 31.6 39.0 47.7 58.5 63.6 72.4 82.6Evaporator pressure drop kPa 39 39 38 36 40 40 43 43 49Available pressure mca 28 27 30 30 28 28 28 28 27Pump absorbed power kW 4.57 4.57 6.26 6.26 8.61 8.61 10.17 10.17 12.22Pump absorbed current A 7.8 7.8 10.4 10.4 14.3 14.3 16.7 16.7 20.3Hydraulic connections BSP/DN DN65 DN65 DN65 DN125 DN125 DN150 DN150 DN150 DN200Tank volume dm3 390 390 390 500 500 500 500 500 500

Fan Section (Axial)

Total air flow m3/h 38000 58000 54000 90000 87500 85000 108000 105000 102000Fans nr. 2 3 3 5 5 5 6 6 6Fans absorbed power kW 3.88 5.82 5.82 9.70 9.70 9.70 11.64 11.64 11.64Fans absorbed current A 7.8 11.7 11.7 19.5 19.5 19.5 23.4 23.4 23.4

Total Electric Data

Nominal absorbed power kW 44.2 56.4 63.9 86.1 95.9 114.3 128.7 149.6 173.4Maximum absorbed current (F.L.A.) A 100.0 125.1 145.3 190.3 232.2 279.8 299.3 337.7 388.9Maximum peak current (L.R.A.) A 221 257 312 365 443 538 439 548 599Electric feed V/Ph/Hz 400/3/50

Noise Data

Sound pressure (2) dB(A) 56.4 59.3 59.7 62.2 62.6 64.9 65.5 66.5 67.1

Dimensions And Weight

Length mm 3350 3350 3350 5350 5350 5350 6350 6350 6350Width mm 1100 1100 1100 1100 1100 1100 1100 1100 1100Height mm 2180 2180 2180 2180 2180 2180 2180 2180 2180Weight empty kg 1265 1440 1595 1915 2115 2160 2390 2560 2720Weight operating kg 1950 2155 2350 2695 3025 3080 3310 3480 3640

(1) Inlet/Outlet water temperature = +12/+7°C - Condenser air temperature = +35°C; fouling factor = 0 .000043 m²K/W (2) Sound pressure level referred to measures according to normative ISO3744, pressure level at distance of 10 m, referred to free field on reflecting surface

7

The complete solution to all your cooling needs

ENR 002 - 480

Optional Accessories

Mechanical Configuration OptionsLN Low noise (compressors jacket, fan speed regulator) Model 008 onwardsCF Condenser aluminium filter Model 002 onwardsCV Epoxy coated aluminium fin coils Model 002 onwardsCC Copper/copper condenser Model 002 onwardsCG Fin guard silver treatment on condenser Model 002 onwards

GALV1 Galvanised main frame Model 002-022, included on 030+

GALV2 Galvanised panels (in conjunction with main frame) Model 002-022, included on 030+

ATS Spring type anti-vibration mounting Model 002 onwardsHydraulic Circuit Configuration OptionsBPA Automatic bypass Model 002 onwardsSS.T.WP Stainless steel hydraulic circuit with plate exchanger, pump & tank Model 002 onwardsNT.NP No tank, no pump, carbon steel with shell & tube evaporator Model 002 onwardsNT No tank, with shell & tube evaporator and pump Model 002 onwardsDP Double pump Model 018 onwardsPH 5 bar pump Model 002 onwardsDPH Double pump with 50 mca with contacts and overload Model 018 onwardsAT Management pumps (in conjunction with DP or DPH) Model 022 onwards

VTP Manual valve between tank & pump (in conjunction with standard version/DP/PH or DPH) Model 002 onwards

RAGT Antifreeze heater internal in tank Model 002 onwardsRAGP Antifreeze heater pump Model 002 onwardsLLA Electric float low level alarm Model 002 onwardsRefrigerant Circuit Configuration OptionsCSV Compressor suction valve Model 008 onwards

HP High pressure gauges Models 002-045, included on models 061+

LP Low pressure gauges Models 030 onwardsPDS De-superheater with plate exchanger Model 030 onwardsPMC Precision leaving temperature (+/-1ºC) Model 002 onwardsLW Low water temperature (outlet until -15ºC) Model 002 onwardsLT Low ambient temperature (until -25ºC) Model 002 onwardsElectric Circuit Configuration OptionsRV Fan speed regulator Model 002 onwardsRVG General voltage relay Model 008 onwardsCSF 3 phases sequences relay Model 008 onwardsOFC On-off compressors signal Model 012 onwardsSF Soft start Model 012 onwardsRemote Connection Arrangement OptionsRS485 Serial card for carel/modbus (RS485) Model 002 onwardsOFR Remote display (on/off) Model 002 onwardsOFRC Remote control with on/off remote + alarm management Model 030 onwardsPacking OptionsWCA Wooden cage packing ISPM15 Model 002 onwardsANS Rubber pad anti-vibrating (shipment) Model 002 onwardsPLT Pallet/ISPM15 pallet Models 002-022

8

Incorporating

9

The complete solution to all your cooling needs

ENR 002 - 480

T: 0845 0941 800 | F: 0845 0941 900 | www.aquacooling.co.uk

Aqua Cooling Solutions Ltd | Unit D4 | Segensworth Business Centre | Segensworth Road | Fareham | Hampshire | PO15 5RQ

Due to continual product development, details contained within this brochure may change without notice and are therefore purely indicative.


Recommended