Going beyond the essentials.
enta100MR/MRL
Reliable and best valued elevator for low-rise buildings.
enta100 MR/MRL going beyond the essentials.
DESIGNED FOR
Low-rise residential buildings
in public and private sector
SPECIFICATIONS
Makes business sense
Gives peace of mind
TK Elevator’s enta100 MR/MRL is a reliable and efficient
elevator that has been designed to fulfill the needs of low rise,
value for money segment. Its smart mechanical design and cost
saving features not only match the essential needs of the Indian
market, but also go beyond them.
Reduced construction cost and e�cient space
utilization provides value for money.
Reliable TK Elevator engineering at
the highest industry standards.
Brightens up your building
Multiple car interior design options to
compliment your building ambience.
3
Machine room and Machineroom-less
Max. travel height: ≤45m
Max. number of stops: ≤16
Max. rated load: 612kg
Rated speed: 1.0m/s
Makes business sense
enta100 MR/MRL is your trustworthy, value for
money elevator solution that meets Indian market needs.
Multiple car and shaft size options
Comes in 6 popular car sizes to
cater to Indian market needs.
ACO/ATO door options
further ensures optimal
building space utilization.
enta100 MR/MRL
machineroom-less solution
reduces the construction cost by
eliminating the need for a
machine room. It also offers
smaller overhead and pit height.
Reduced construction cost
Fast & e�ectiveinstallation
4
enta100’s smart mechanical
setup using pre-assembled
components, surface mounted
fixtures and scaffold-less
installation makes it fast, safe
and cost effective to install.
Gives peace of mind
enta100 MR/MRL reliable engineering and cost efficient
operations provides peace of mind to the users.
Reduced energy bill.
Active safety features such as
overload notification, full load
bypass and full height light
curtains ensures passenger
safety. Passive safety features
such as emergency light and
alarm in the COP, automatic
rescue device and fireman switch
adds to passenger safety.
Designed for a safe ride.
Energy efficient components
and features ensure efficient
operations. Compact and
lightweight Gearless
Permanent Magnetic
Synchronous (PMS) motor
consumes 30% less energy
than conventional geared
machines.
enta100 MR/MRL is
engineered to match TK
Elevator standards based
on stringent German
product design criteria.
Engineered to match TK Elevator standards.
5
Brightens up your building
enta100 MR/MRL interior designs and fixtures are
designed to enhance your building ambience.
FixturesEvery user interaction point is an
opportunity to delight.
AestheticsSelected by our in-house design
team for your personal composition.
AccessoriesA chance to enhance the user
experience t hrough design detail.
6
FIXTURES
Type Slim Slim
Faceplate SSHL SSHL
Indicator Red Dot Matrix Red Dot Matrix
Button MT42 AN180
Illumination Red Red
Type Simplex LS3A Duplex LD3A
Faceplate SSHL SSHL
Indicator Red Dot Matrix Red Dot Matrix
Button AN180 MT42
Illumination Red Red
LIOP
*Note: LIOPs are wall mounted on landing floor wall.
* Wall mounted, slim COP without back box.
COP
Mirror
Ceiling
Buttons
7
Round handrail diameter 38mm,
SS Hairline, Open ended
*Handrail positions: Only at rear side of cabin
*In case of half-length mirror on rear wall,
the handrail on rear wall is mandatory.
Handrail
User friendly controls and panels make every passenger journey a delight
AN180
MT42
A mix of soothing and vibrant pastel shades
imbues positivity and calmness in the atmosphere.
Slim COP
SOOTHING
INDIGO2 CeilingSignal White
PVC Royal Black
Side Wall
Floor
Light BlueRear WallLight Blue
Front Wall Light Blue
Door Light Blue
8
ELAN1 CeilingSignal White
PVC Royal Black
Side Wall
Floor
Oyster WhiteRear WallOyster White
Front Wall Oyster White
Door Oyster White
21
ELEGANT
DAPPER1 CeilingSS type Silver Finish
PVC Royal Black
Side Wall
Floor
Stainless steel hairline
Rear WallStainless steel hairline
Front Wall Stainless steel hairline
Door Stainless steel hairline
Elegant Stainless Steel finishes give
a contemporary look and feel to the elevator.
9
EXALT2 CeilingSS type Silver Finish
PVC Royal Black
Side Wall
Floor
Stainless steellinen
Rear WallStainless steellinen
Front Wall Stainless steellinen
Door Stainless steellinen
21
Slim COP
enta100 MR/MRL
LAYOUT
1 0
Machineroom planMR shaft vertical section MRL shaft vertical section
Top floor MR elevator plan
Top floor MRL elevator plan
Above illustration is of automatic centre opening
Above illustration is of automatic centre opening
Ma
ch
ine
ro
om
he
igh
tO
ve
rhe
ad
he
igh
tT
rav
el h
eig
ht
Ov
erh
ea
d h
eig
ht
Tra
ve
l he
igh
tP
it d
ep
th
Pit
de
pth
Controller
Machine room width
Ma
ch
ine
ro
om
de
pth
Controller
Door width
Car width
Shaft width
Ca
r d
ep
th
Sh
aft
de
pth
Ca
r d
ep
th
Sh
aft
de
pth
Door width
Car width
Shaft width
DOOR TYPE
DOOR WIDTH(DW) MM
CAR SIZE (CW X CD) (MM)
SHAFT SIZE (MIN)(SW X SD) (MM)
SHAFT SIZE (MAX)(SW X SD) (MM)
ACO 700
0850 x 1100
0850 x 1100
ATO 700
ACO 700
1000 x 1100
1000 x 1100
ATO 800
ACO 800
1100 x 1100
1100 x 1100
ATO 800
ACO 800
1100 x 1200
1100 x 1200
ATO 800
ACO 800
1100 x 1300
1100 x 1300
ATO 800
ACO 800
1100 x 1400
1100 x 1400
ATO 800
1600 x 1480
1480 x 1560
1630 x 1480
1630 x 1560
1740 x 1480
1730 x 1560
1740 x 1530
1730 x 1610
1740 x 1615
1730 x 1695
1740 x 1715
1730 x 1795
1725 x 1810
1725 x 1890
1875 x 1810
1875 x 1890
1975 x 1810
1975 x 1890
1975 x 1910
1975 x 1990
1975 x 2010
1975 x 2090
1975 x 2110
1975 x 2190
RATEDLOAD (KG)
340 5
408 6
476 7
544 8
612 9
Machine Room Dimensions
MRH = 2200mm
MRW = SW+500mm (Machine room side extension at Machine side)
MRD = SD
Abbreviations:CW: Car width, CD: Car depth, CH: Car height (Car inside clear height), DW: Door width, DH: Door height, SW: Shaft width, SD: Shaft depth, ACO: Automatic center opening, ATO: Automatic telescopic opening, FTFH: Floor to floor height, TH: Travel height, OH: Overhead, PD: Pit depth, MR: Machine room, MRW: Machine room width, MRD: Machine room depth, MRH: Machine room height
GENERAL PLANNING DATA
Load (kg)
No. of passengers
Rated speed (V) m/s
Max. travel height (TH) mm
Max. stops
Max. group size
Minimum pit depth (PD) mm
Minimum floor to floor height (FTFH), mm
Maximum floor to floor height (FTFH), mm
340/ 408/ 476/ 544/ 612
5/6/7/8/9
1.0
45000
16
2 cars
1400
Door height + 600
11000*
FEATURES DESCRIPTIONCAR HEIGHT (CH) MM
DOOR HEIGHT (DH) MM
OVERHEAD (OH) MM
MR MRL
2100
2200
2300
2400
2000
2000, 2100
2100, 2200
2200
3300
3400
3500
3600
3800
3800
3800
3800
Minimum overhead (OH) mm with respect to car & door height
Shaft wall construction can be Concrete or Brick.
PERMITTED DEVIATION FOR SW & SD
Shaft height (SH) mm
Permitted deviation
<30000
0~+25mm
>30000 <=60000
0~+35mm
Please follow the dimensions and tolerances provided above when planning your elevator shaft.
If you require any further information, our sales representatives will be happy to help.
enta100 MR/MRL
PLANNING DIMENSIONS
1 1
* If floor to floor height is more than 11000, emergency landing to be provided.
PAXCAPACITY
ACVVVF closed loop drive
Automatic operation for car fan and light
Full load by-pass
2 Car group, with independent operation feature
Dot matrix scrolling display in COP, LIOP
Door open/door close buttons in car operating panel
Car arrival chime on car top
Hall lantern (applicable for duplex only)
Provision for music system wiring (in travelling cable)
Voice announcement unit (English language only)
Braille on push buttons
Intercom 3-way (elevator car, controller and lobby/security)
Interface to Building Monitoring System (BMS) through potential free contacts/RS485
Car call cancellation by double pressing floor button in car operating panel
Anti-nuisance limit number of car call when empty car
Anti-nuisance (car call cancellation at direction reversal)
Home landing
Advance door opening
Re-levelling with door open
Floor blocking (floor out of service)
Parking operation (key switch in landing operating panel)
Re-level to nearest floor at power on
Adjustable waiting time for opening door at the main landing
Next landing: onward travel to the next stop in the case of a non-opening door
enta100 MR/MRL
FUNCTION LIST
CATEGORY NO. FUNCTIONSTANDARD/ OPTION
Note: S - Standard O - Option
S
S
S
O
S
S
O
O
O
O
S
S
O
S
S
S
S
O
O
O
O
O
S
S
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Enhanced Car Function
Group/Duplex control
Human Machine Interface
Monitoring
Passenger Comfort
1 2
enta100 MR/MRL
FUNCTION LIST
CATEGORY NO. FUNCTIONSTANDARD/ OPTION
Note: S - Standard O - Option
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
All product specifications and parameters specified in this brochure are recorded according to the data valid at the time it was printed. TK Elevator India is entitled to,
upon its sole discretion, adjust the relevant technical specifications and/or other parameters according to the actual production situation. Kindly contact the local
representative or the nearest sales branch of TK Elevator when purchasing our products. TK Elevator India reserves the sale and exclusive interpretation right on any
and all content in this brochure.
Safety & Emergency Function
Security
S
S
S
S
S
S
S
S
S
S
S
O
O
O
O
O
O
O
O
O
Alarm button in COP with battery back-up
Adjustable door open time
Door closing retries
Emergency light in COP
Full height 2D infrared screen for car door
Inspection operation from controller and car top
Jammed landing operating panel call button by-pass
Motor overheat protection
Overload function with audio-visual indication in car operating panel
Phase failure and Phase reversal protection
Fire emergency return
Fireman operation
Auto rescue device in case of power failure (Standard for MRL)
Door nudging
Earthquake function (earthquake sensors by customer)
VIP Operation (landing operating panel VIP Function)
Compulsory stop floor
Attendant control
Independent operation (car VIP function)
Provision for CCTV camera signals (in travelling cable)
1 3
50,000+
24,000+
1,200,000 100+
1,000+24/7
Elevators and escalators under maintenance
Employees
Service technicians
Customers in countries
LocationsService available for customers
YOUR INNOVATIONPARTNER
Agartala, Agra, Ajmer, Akola, Allahabad, Amravati, Amritsar,
Aurangabad, Bareilly, Belgaum, Bhatinda, Bhilai, Bhopal, Bhutan,
Bokaro, Chandrapur, Cuttack, Davangere, Dehradun, DIAL-Delhi,
Durgapur, Erode, Gorakhpur, Gwalior, Hospet, Hubli, Jabalpur,
Jalandhar, Jammu/Katra, Jharsuguda, Jorhat, Kannur, Kanpur, Karur,
Karwar, Kolhapur, Kollam, Kota, Kottayam, Ludhiana, Madurai,
Mysore, Nagpur, Nashik, Palakkad, Panipat/Sonipat, Patna,
Pondicherry, Rajkot, Raichur, Ranchi, Salem, Satna, Shaktinagar,
Shimoga, Sikkim, Siliguri, Solan, Srinagar, Surat, Thrissur, Tirunelveli,
Tirupati, Tirupur, Trichy, Trivandrum, Tuticorin, Udaipur, Udupi,
Manipal, Valsad, Varanasi, Vijayawada, Visakhapatnam & Vadodara.
Service Response Centres (SRC)
State-of-the art, Multi-Purpose Facility
with HQ, Production Facility, Central
Warehouse, Centralized Call Center,
Experience Center, Training Center/SEED,
Product Showroom and Test Shafts at
Chakan, Pune
Guwahati
Jamshedpur
KOLKATA
Bhubaneswar
Chandigarh
Lucknow
BENGALURU
Coimbatore
Calicut
Cochin
Raipur
Indore
PUNE
Ahmedabad
MUMBAINavi Mumbai
GurugramNEW DELHI
NoidaJaipur
Hyderabad
Goa
Chennai
North Region
6 Branches
East Region
4 Branches
West Region
6 Branches
South Region
7 Branches
PAN India network
Nation-wide network of 4 Regional Offices,
23 Branches and 74 Service and Response Centres.
HQ RO Branch SRC MPF 1 5
en
ta10
0 E
ng
lish
(0
4/2
02
1) T
K E
leva
tor
Inn
ova
tio
n a
nd
Op
era
tio
ns
Gm
bH
Asi
a P
ac
ific
O�
ce
Th
e d
eta
ils q
uo
ted
in t
his
bro
ch
ure
ca
n o
nly
be
vie
we
d a
s b
ind
ing
wh
en
co
nfi
rme
d e
xpre
ssly
in w
riti
ng
. Re
pro
du
cti
on
, re
pri
nt
an
d s
tora
ge
on
ly w
ith
au
tho
riza
tio
n o
f th
e e
dit
or.
WWW.TKELEVATOR.COM/IN-EN/