Page 2: enta100 MR-MRL Final
Page 3: enta100 MR-MRL Final

enta100 MR/MRL going beyond the essentials.

DESIGNED FOR

Low-rise residential buildings

in public and private sector

SPECIFICATIONS

Makes business sense

Gives peace of mind

TK Elevator’s enta100 MR/MRL is a reliable and efficient

elevator that has been designed to fulfill the needs of low rise,

value for money segment. Its smart mechanical design and cost

saving features not only match the essential needs of the Indian

market, but also go beyond them.

Reduced construction cost and e�cient space

utilization provides value for money.

Reliable TK Elevator engineering at

the highest industry standards.

Brightens up your building

Multiple car interior design options to

compliment your building ambience.

3

Machine room and Machineroom-less

Max. travel height: ≤45m

Max. number of stops: ≤16

Max. rated load: 612kg

Rated speed: 1.0m/s

Page 4: enta100 MR-MRL Final

Makes business sense

enta100 MR/MRL is your trustworthy, value for

money elevator solution that meets Indian market needs.

Multiple car and shaft size options

Comes in 6 popular car sizes to

cater to Indian market needs.

ACO/ATO door options

further ensures optimal

building space utilization.

enta100 MR/MRL

machineroom-less solution

reduces the construction cost by

eliminating the need for a

machine room. It also offers

smaller overhead and pit height.

Reduced construction cost

Fast & e�ectiveinstallation

4

enta100’s smart mechanical

setup using pre-assembled

components, surface mounted

fixtures and scaffold-less

installation makes it fast, safe

and cost effective to install.

Page 5: enta100 MR-MRL Final

Gives peace of mind

enta100 MR/MRL reliable engineering and cost efficient

operations provides peace of mind to the users.

Reduced energy bill.

Active safety features such as

overload notification, full load

bypass and full height light

curtains ensures passenger

safety. Passive safety features

such as emergency light and

alarm in the COP, automatic

rescue device and fireman switch

adds to passenger safety.

Designed for a safe ride.

Energy efficient components

and features ensure efficient

operations. Compact and

lightweight Gearless

Permanent Magnetic

Synchronous (PMS) motor

consumes 30% less energy

than conventional geared

machines.

enta100 MR/MRL is

engineered to match TK

Elevator standards based

on stringent German

product design criteria.

Engineered to match TK Elevator standards.

5

Page 6: enta100 MR-MRL Final

Brightens up your building

enta100 MR/MRL interior designs and fixtures are

designed to enhance your building ambience.

FixturesEvery user interaction point is an

opportunity to delight.

AestheticsSelected by our in-house design

team for your personal composition.

AccessoriesA chance to enhance the user

experience t hrough design detail.

6

Page 7: enta100 MR-MRL Final

FIXTURES

Type Slim Slim

Faceplate SSHL SSHL

Indicator Red Dot Matrix Red Dot Matrix

Button MT42 AN180

Illumination Red Red

Type Simplex LS3A Duplex LD3A

Faceplate SSHL SSHL

Indicator Red Dot Matrix Red Dot Matrix

Button AN180 MT42

Illumination Red Red

LIOP

*Note: LIOPs are wall mounted on landing floor wall.

* Wall mounted, slim COP without back box.

COP

Mirror

Ceiling

Buttons

7

Round handrail diameter 38mm,

SS Hairline, Open ended

*Handrail positions: Only at rear side of cabin

*In case of half-length mirror on rear wall,

the handrail on rear wall is mandatory.

Handrail

User friendly controls and panels make every passenger journey a delight

AN180

MT42

Page 8: enta100 MR-MRL Final

A mix of soothing and vibrant pastel shades

imbues positivity and calmness in the atmosphere.

Slim COP

SOOTHING

INDIGO2 CeilingSignal White

PVC Royal Black

Side Wall

Floor

Light BlueRear WallLight Blue

Front Wall Light Blue

Door Light Blue

8

ELAN1 CeilingSignal White

PVC Royal Black

Side Wall

Floor

Oyster WhiteRear WallOyster White

Front Wall Oyster White

Door Oyster White

21

Page 9: enta100 MR-MRL Final

ELEGANT

DAPPER1 CeilingSS type Silver Finish

PVC Royal Black

Side Wall

Floor

Stainless steel hairline

Rear WallStainless steel hairline

Front Wall Stainless steel hairline

Door Stainless steel hairline

Elegant Stainless Steel finishes give

a contemporary look and feel to the elevator.

9

EXALT2 CeilingSS type Silver Finish

PVC Royal Black

Side Wall

Floor

Stainless steellinen

Rear WallStainless steellinen

Front Wall Stainless steellinen

Door Stainless steellinen

21

Slim COP

Page 10: enta100 MR-MRL Final

enta100 MR/MRL

LAYOUT

1 0

Machineroom planMR shaft vertical section MRL shaft vertical section

Top floor MR elevator plan

Top floor MRL elevator plan

Above illustration is of automatic centre opening

Above illustration is of automatic centre opening

Ma

ch

ine

ro

om

he

igh

tO

ve

rhe

ad

he

igh

tT

rav

el h

eig

ht

Ov

erh

ea

d h

eig

ht

Tra

ve

l he

igh

tP

it d

ep

th

Pit

de

pth

Controller

Machine room width

Ma

ch

ine

ro

om

de

pth

Controller

Door width

Car width

Shaft width

Ca

r d

ep

th

Sh

aft

de

pth

Ca

r d

ep

th

Sh

aft

de

pth

Door width

Car width

Shaft width

Page 11: enta100 MR-MRL Final

DOOR TYPE

DOOR WIDTH(DW) MM

CAR SIZE (CW X CD) (MM)

SHAFT SIZE (MIN)(SW X SD) (MM)

SHAFT SIZE (MAX)(SW X SD) (MM)

ACO 700

0850 x 1100

0850 x 1100

ATO 700

ACO 700

1000 x 1100

1000 x 1100

ATO 800

ACO 800

1100 x 1100

1100 x 1100

ATO 800

ACO 800

1100 x 1200

1100 x 1200

ATO 800

ACO 800

1100 x 1300

1100 x 1300

ATO 800

ACO 800

1100 x 1400

1100 x 1400

ATO 800

1600 x 1480

1480 x 1560

1630 x 1480

1630 x 1560

1740 x 1480

1730 x 1560

1740 x 1530

1730 x 1610

1740 x 1615

1730 x 1695

1740 x 1715

1730 x 1795

1725 x 1810

1725 x 1890

1875 x 1810

1875 x 1890

1975 x 1810

1975 x 1890

1975 x 1910

1975 x 1990

1975 x 2010

1975 x 2090

1975 x 2110

1975 x 2190

RATEDLOAD (KG)

340 5

408 6

476 7

544 8

612 9

Machine Room Dimensions

MRH = 2200mm

MRW = SW+500mm (Machine room side extension at Machine side)

MRD = SD

Abbreviations:CW: Car width, CD: Car depth, CH: Car height (Car inside clear height), DW: Door width, DH: Door height, SW: Shaft width, SD: Shaft depth, ACO: Automatic center opening, ATO: Automatic telescopic opening, FTFH: Floor to floor height, TH: Travel height, OH: Overhead, PD: Pit depth, MR: Machine room, MRW: Machine room width, MRD: Machine room depth, MRH: Machine room height

GENERAL PLANNING DATA

Load (kg)

No. of passengers

Rated speed (V) m/s

Max. travel height (TH) mm

Max. stops

Max. group size

Minimum pit depth (PD) mm

Minimum floor to floor height (FTFH), mm

Maximum floor to floor height (FTFH), mm

340/ 408/ 476/ 544/ 612

5/6/7/8/9

1.0

45000

16

2 cars

1400

Door height + 600

11000*

FEATURES DESCRIPTIONCAR HEIGHT (CH) MM

DOOR HEIGHT (DH) MM

OVERHEAD (OH) MM

MR MRL

2100

2200

2300

2400

2000

2000, 2100

2100, 2200

2200

3300

3400

3500

3600

3800

3800

3800

3800

Minimum overhead (OH) mm with respect to car & door height

Shaft wall construction can be Concrete or Brick.

PERMITTED DEVIATION FOR SW & SD

Shaft height (SH) mm

Permitted deviation

<30000

0~+25mm

>30000 <=60000

0~+35mm

Please follow the dimensions and tolerances provided above when planning your elevator shaft.

If you require any further information, our sales representatives will be happy to help.

enta100 MR/MRL

PLANNING DIMENSIONS

1 1

* If floor to floor height is more than 11000, emergency landing to be provided.

PAXCAPACITY

Page 12: enta100 MR-MRL Final

ACVVVF closed loop drive

Automatic operation for car fan and light

Full load by-pass

2 Car group, with independent operation feature

Dot matrix scrolling display in COP, LIOP

Door open/door close buttons in car operating panel

Car arrival chime on car top

Hall lantern (applicable for duplex only)

Provision for music system wiring (in travelling cable)

Voice announcement unit (English language only)

Braille on push buttons

Intercom 3-way (elevator car, controller and lobby/security)

Interface to Building Monitoring System (BMS) through potential free contacts/RS485

Car call cancellation by double pressing floor button in car operating panel

Anti-nuisance limit number of car call when empty car

Anti-nuisance (car call cancellation at direction reversal)

Home landing

Advance door opening

Re-levelling with door open

Floor blocking (floor out of service)

Parking operation (key switch in landing operating panel)

Re-level to nearest floor at power on

Adjustable waiting time for opening door at the main landing

Next landing: onward travel to the next stop in the case of a non-opening door

enta100 MR/MRL

FUNCTION LIST

CATEGORY NO. FUNCTIONSTANDARD/ OPTION

Note: S - Standard O - Option

S

S

S

O

S

S

O

O

O

O

S

S

O

S

S

S

S

O

O

O

O

O

S

S

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Enhanced Car Function

Group/Duplex control

Human Machine Interface

Monitoring

Passenger Comfort

1 2

Page 13: enta100 MR-MRL Final

enta100 MR/MRL

FUNCTION LIST

CATEGORY NO. FUNCTIONSTANDARD/ OPTION

Note: S - Standard O - Option

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

All product specifications and parameters specified in this brochure are recorded according to the data valid at the time it was printed. TK Elevator India is entitled to,

upon its sole discretion, adjust the relevant technical specifications and/or other parameters according to the actual production situation. Kindly contact the local

representative or the nearest sales branch of TK Elevator when purchasing our products. TK Elevator India reserves the sale and exclusive interpretation right on any

and all content in this brochure.

Safety & Emergency Function

Security

S

S

S

S

S

S

S

S

S

S

S

O

O

O

O

O

O

O

O

O

Alarm button in COP with battery back-up

Adjustable door open time

Door closing retries

Emergency light in COP

Full height 2D infrared screen for car door

Inspection operation from controller and car top

Jammed landing operating panel call button by-pass

Motor overheat protection

Overload function with audio-visual indication in car operating panel

Phase failure and Phase reversal protection

Fire emergency return

Fireman operation

Auto rescue device in case of power failure (Standard for MRL)

Door nudging

Earthquake function (earthquake sensors by customer)

VIP Operation (landing operating panel VIP Function)

Compulsory stop floor

Attendant control

Independent operation (car VIP function)

Provision for CCTV camera signals (in travelling cable)

1 3

Page 14: enta100 MR-MRL Final

50,000+

24,000+

1,200,000 100+

1,000+24/7

Elevators and escalators under maintenance

Employees

Service technicians

Customers in countries

LocationsService available for customers

YOUR INNOVATIONPARTNER

Page 15: enta100 MR-MRL Final

Agartala, Agra, Ajmer, Akola, Allahabad, Amravati, Amritsar,

Aurangabad, Bareilly, Belgaum, Bhatinda, Bhilai, Bhopal, Bhutan,

Bokaro, Chandrapur, Cuttack, Davangere, Dehradun, DIAL-Delhi,

Durgapur, Erode, Gorakhpur, Gwalior, Hospet, Hubli, Jabalpur,

Jalandhar, Jammu/Katra, Jharsuguda, Jorhat, Kannur, Kanpur, Karur,

Karwar, Kolhapur, Kollam, Kota, Kottayam, Ludhiana, Madurai,

Mysore, Nagpur, Nashik, Palakkad, Panipat/Sonipat, Patna,

Pondicherry, Rajkot, Raichur, Ranchi, Salem, Satna, Shaktinagar,

Shimoga, Sikkim, Siliguri, Solan, Srinagar, Surat, Thrissur, Tirunelveli,

Tirupati, Tirupur, Trichy, Trivandrum, Tuticorin, Udaipur, Udupi,

Manipal, Valsad, Varanasi, Vijayawada, Visakhapatnam & Vadodara.

Service Response Centres (SRC)

State-of-the art, Multi-Purpose Facility

with HQ, Production Facility, Central

Warehouse, Centralized Call Center,

Experience Center, Training Center/SEED,

Product Showroom and Test Shafts at

Chakan, Pune

Guwahati

Jamshedpur

KOLKATA

Bhubaneswar

Chandigarh

Lucknow

BENGALURU

Coimbatore

Calicut

Cochin

Raipur

Indore

PUNE

Ahmedabad

MUMBAINavi Mumbai

GurugramNEW DELHI

NoidaJaipur

Hyderabad

Goa

Chennai

North Region

6 Branches

East Region

4 Branches

West Region

6 Branches

South Region

7 Branches

PAN India network

Nation-wide network of 4 Regional Offices,

23 Branches and 74 Service and Response Centres.

HQ RO Branch SRC MPF 1 5

Page 16: enta100 MR-MRL Final

en

ta10

0 E

ng

lish

(0

4/2

02

1) T

K E

leva

tor

Inn

ova

tio

n a

nd

Op

era

tio

ns

Gm

bH

Asi

a P

ac

ific

O�

ce

Th

e d

eta

ils q

uo

ted

in t

his

bro

ch

ure

ca

n o

nly

be

vie

we

d a

s b

ind

ing

wh

en

co

nfi

rme

d e

xpre

ssly

in w

riti

ng

. Re

pro

du

cti

on

, re

pri

nt

an

d s

tora

ge

on

ly w

ith

au

tho

riza

tio

n o

f th

e e

dit

or.

WWW.TKELEVATOR.COM/IN-EN/


Recommended