+ All Categories
Home > Documents > EPUBLIC HRC 500/501/600/700 MANUFACTURING …REGENERATIVE BLOWERS REPUBLIC MANUFACTURING HRC...

EPUBLIC HRC 500/501/600/700 MANUFACTURING …REGENERATIVE BLOWERS REPUBLIC MANUFACTURING HRC...

Date post: 09-Aug-2020
Category:
Upload: others
View: 7 times
Download: 0 times
Share this document with a friend
2
PERFORMANCE Republic offers a complete line of regenerative blowers for high vacuum or compressed air applications in both horizontal and vertical mounted positions. TEFC motors are rated for 50/60 Hz operation and are IE3, cUL, UL, and CE certified. The impeller is directly connected to the motor shaft, providing powerful air force without undue friction. The bearings are outside the compression chamber, ensuring maximum operational reliability under high differential pressure. Constructed in robust die- cast aluminum, this low-maintenance, oil-free design provides continuous, dependable service to our customers. REGENERATIVE BLOWERS HRC 500/501/600/700 R MANUFACTURING EPUBLIC The performance curves are based on air at a temperature of 59 o F and an atmospheric pressure of 29.91 inch Hg with a tolerance of +/-10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 o F. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are +/-10% for fixed voltage motors and +/-5% for voltage range motors. Single phase machines are designed with a +/-5% tolerance. The frequency tolerance is +/-2% maximum. Vacuum Pressure ©Republic Manufacturing 0 -200 50 100 200 300 Pressure -100 in. H2O m /hr 3 Vacuum mbar cfm 700 100 400 0 -300 0 100 300 0 600 500 500 400 200 100 200 -100 -200 -400 300 200 -500 500 500 600 700 700 600 500 700 600 500 Suction Capacity Total Pressure Difference 50 Hz 60 Hz 50 Hz 60 Hz 501 501 501 501 Model Phase Frequency (Hz) Air flow (CFM/m 3/ hr) Rated Vacuum (in. H 2 O/mbar) Rated Pressure (in. H 2 O/mbar) Motor (HP/kW) Voltage (V) Current (A) Sound Level (dB) Weight (lb/kg) HRC 500 3 50 187/318 76/190 76/190 3.0/2.2 190 YY/380 Y 11.2 YY/5.6 Y 69 68/31 60 221/376 76/190 76/190 3.4/2.5 230 YY/460Y 10.3 YY/6.0 Y 72 HRC 600 3 50 187/318 104/260 108/270 4.0/3.0 190 YY/380 Y 12.5 YY/7.2 Y 69 79/36 60 221/376 96/240 92/230 4.6/3.4 230 YY/460 Y 12.6 YY/7.3 Y 72 HRC 700 3 50 187/318 116/290 132/330 5.4/4.0 190 rr/380 r 18.0 rr/9.0 r 69 88/40 60 221/376 128/320 124/310 6.2/4.6 230 rr/460 r 17.1 rr/9.9 r 72 HRC 501 1 50 187/318 76/190 76/190 3.0/2.2 220 15.5 72 66/30 60 221/376 72/180 72/180 3.4/2.5 220 15.5 74 IE3 CC339B E493872
Transcript
Page 1: EPUBLIC HRC 500/501/600/700 MANUFACTURING …REGENERATIVE BLOWERS REPUBLIC MANUFACTURING HRC 500/501/600/700 The performance curves are based on air at a temperature of 59 oF and an

PERFORMANCE

Republic offers a complete line of regenerative blowers for high vacuum or compressed air applications in both horizontal and vertical mounted positions. TEFC motors are rated for 50/60 Hz operation and are IE3, cUL, UL, and CE certified. The impeller is directly connected to the motor shaft, providing powerful air force without undue friction. The bearings are outside the compression chamber, ensuring maximum operational reliability under high differential pressure. Constructed in robust die-cast aluminum, this low-maintenance, oil-free design provides continuous, dependable service to our customers.

REGENERATIVE BLOWERSHRC 500/501/600/700RMANUFACTURING

EPUBLIC

The performance curves are based on air at a temperature of 59 oF and an atmospheric pressure of 29.91 inch Hg with a tolerance of +/-10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 oF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are +/-10% for fixed voltage motors and +/-5% for voltage range motors. Single phase machines are designed with a +/-5% tolerance. The frequency tolerance is +/-2% maximum.

Vacuum Pressure

©Republic Manufacturing

0-200

50

100

200

300

Pressure

-100 in. H2Om /hr3

Vacuum

mbar

cfm

700

100 4000-300

0

100

300

0

600

500

500

400

200

100 200

-100-200-400 300200-500 500

500

600

700

700600

500

700

600

500

Suct

ion

Capa

city

Total Pressure Di�erence

50 Hz60 Hz

50 Hz60 Hz

501501

501501

Model PhaseFrequency

(Hz)Air flow

(CFM/m3/hr)Rated Vacuum (in. H2O/mbar)

Rated Pressure (in. H2O/mbar)

Motor(HP/kW)

Voltage(V)

Current(A)

Sound Level (dB)

Weight (lb/kg)

HRC 500 350 187/318 76/190 76/190 3.0/2.2 190 YY/380 Y 11.2 YY/5.6 Y 69

68/3160 221/376 76/190 76/190 3.4/2.5 230 YY/460Y 10.3 YY/6.0 Y 72

HRC 600 350 187/318 104/260 108/270 4.0/3.0 190 YY/380 Y 12.5 YY/7.2 Y 69

79/3660 221/376 96/240 92/230 4.6/3.4 230 YY/460 Y 12.6 YY/7.3 Y 72

HRC 700 350 187/318 116/290 132/330 5.4/4.0 190 rr/380 r 18.0 rr/9.0 r 69

88/4060 221/376 128/320 124/310 6.2/4.6 230 rr/460 r 17.1 rr/9.9 r 72

HRC 501 150 187/318 76/190 76/190 3.0/2.2 220 15.5 72

66/3060 221/376 72/180 72/180 3.4/2.5 220 15.5 74

IE3 CC339B

E493872

Page 2: EPUBLIC HRC 500/501/600/700 MANUFACTURING …REGENERATIVE BLOWERS REPUBLIC MANUFACTURING HRC 500/501/600/700 The performance curves are based on air at a temperature of 59 oF and an

©Republic Manufacturing • Revised 20200811

APPROXIMATE DIMENSIONS

All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD’s, PLC’s, or starter panels.

Available Options

VACUUM KIT PRESSURE KIT

RMANUFACTURINGEPUBLIC 5131 Cash Road, Dallas, TX 75247, USA

800.847.0380 • [email protected] • republic-mfg.com

Model Unit A B D E F G J K M N O P Q R S T U V W

HRC500

in 15.04 16.54M10

14.84 5.12 7.48 5.04 7.682.00

3.27 0.18 2.00 7.09 12.80 11.42 4.29 5.51 13.07 0.59

mm 382 420 377 130 190 128 195 83 4.5 51 180 325 290 109 140 332 15

HRC600

in 15.04 16.54M10

16.10 5.12 7.40 5.31 7.682.00

3.27 0.18 2.00 7.09 12.80 11.42 4.29 5.51 13.07 0.59

mm 382 420 409 130 188 135 195 83 4.5 51 180 325 290 109 140 332 15

HRC700

in 15.04 16.54M10

16.10 5.12 7.40 5.31 7.682.00

3.27 0.18 2.00 7.09 12.80 11.42 4.29 5.51 13.07 0.59

mm 382 420 409 130 188 135 195 83 4.5 51 180 325 290 109 140 332 15

HRC501

in 15.04 16.54M10

14.84 5.12 7.48 5.04 7.682.00

3.27 0.18 2.00 7.09 12.80 11.42 4.29 5.51 13.07 0.59

mm 382 420 377 130 190 128 195 83 4.5 51 180 325 290 109 140 332 15


Recommended