Equinox 3411|3412
Modern square or round shape with slim profile featuring two cylindrical windows that creates a graphic statement.‘‘ ’ ’
BEAMS, FINISHES, SHAPESAvailable in either a round or square shape, the Equinox can be ordered in exterior grade anthracite or precision satin aluminum finish and a choice of narrow or flood beam angle.
flood beam
narrow beam
anthracite tour de force
Anatomy Photometric Report
34113412
ANATOMY EQUINOX
CHARACTERISTICS 3411 / 3412
LIGHT SOURCEMODULEDELIVERED LUMENS*
* Results for 2FL beam option
CRIHOUSINGLIGHT DISTRIBUTIONOPTICS
VOLTAGEDRIVERLM-79WARRANTY
2 x 1W HIGH POWER LED on MCPCB - Total ±2W 2 x 2W HIGH POWER LED on MCPCB - Total ±4WUL Recognized, Made in the U.S.A.250lm (4000K) 450lm (4000K)80 CRI (typical)Machined aluminum, anthracite or black fine texture (exterior) or satin aluminum finish (indoor only)Wide or Narrow beams availableCrystal clear glass openings
GASKETS Die-cut self-adhesive silicone gasket120VConstant current 350mA, UL recognized Constant current 700mA, UL recognizedOn request On request5 years
V3.1-201709www.eurekalighting.comEureka Lighting©2017
3411EQUINOX ROUND
3411EQUINOX ROUND
3411EQUINOX ROUNDNARROW BEAM
3411EQUINOX ROUNDWIDE BEAM
3412EQUINOX SQUARE
3412EQUINOX SQUARE
Ø 4.46”Ø 113mm
Ø 4.46”Ø 113mm
Ø 2.50”Ø 63.5mm
Ø 4.46”Ø 113mm
ADA COMPLIANTConform to ADA regulations as it extends less than 4” from the installation surface
GRAPHIC STATEMENTModern square or round shape with slim profile creating a graphic statement with the option of narrow or wide beam angles
HIGH POWERED LEDDual HIGH POWERED LED acheiving the desired light effect with minimum wattage consumption
INTEGRATED DRIVERThe electronic driver is included in the product
WEATHERPROOFSelf-adhesive gasketsFully sealed machined aluminum bodyPressed crystal glassAnthracite or black exterior grade finishStainless Steel hardware
HEAVY DUTY The EQUINOX features a thick machined aluminum body making it resistant to the toughest environements.
IP 65 UL WET
225 de Liège Ouest, Suite #200 Montréal (QC), Canada H2P 1H4 Tel : 514.385.3515 Fax : 514.385.4169 www.eurekalighting.com
Number of lamps: Lumens per lamp:Input watts:Distribution:E�ciency:Photometric type:
Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:
Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:
22254.9
Direct-Indirect5.7
C
RectangleFeet0.210.370.37
0.910.190.31
© 2014 EUREKA LIGHTINGwww.eurekalighting.com
341X-2NS-LED402X2Equinox RD or SQ - NARROW BEAM - 4000K - 2x2W
Equinox RD & SQ
Photometric Report
0 - 18090 - 270
anglescd
0.0 10.0 20.0
30.0
40.0
50.0
60.0
70.080.090.0
100.0110.0
120.0
130.0
140.0
150.0
160.0170.0180.0
0
7
7
15
15
22
22
29
29
37
37
44
44
52
52
59
59
66
66
Number of lamps: Lumens per lamp:Input watts:Distribution:E�ciency:Photometric type:
Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:
Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:
22254.9
Direct-Indirect5.7
C
RectangleFeet0.210.370.37
0.910.190.31
© 2014 EUREKA LIGHTINGwww.eurekalighting.com
341X-2NS-LED402X2Equinox RD or SQ - NARROW BEAM - 4000K - 2x2W
Equinox RD & SQ
Photometric Report
0 - 18090 - 270
anglescd
0.0 10.0 20.0
30.0
40.0
50.0
60.0
70.080.090.0
100.0110.0
120.0
130.0
140.0
150.0
160.0170.0180.0
0
7
7
15
15
22
22
29
29
37
37
44
44
52
52
59
59
66
66
Number of lamps: Lumens per lamp:Input watts:Distribution:E�ciency:Photometric type:
Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:
Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:
22254.9
Direct-Indirect5.7
C
RectangleFeet0.210.370.37
0.910.190.31
© 2014 EUREKA LIGHTINGwww.eurekalighting.com
341X-2NS-LED402X2Equinox RD or SQ - NARROW BEAM - 4000K - 2x2W
Equinox RD & SQ
Photometric Report
0 - 18090 - 270
anglescd
0.0 10.0 20.0
30.0
40.0
50.0
60.0
70.080.090.0
100.0110.0
120.0
130.0
140.0
150.0
160.0170.0180.0
0
7
7
15
15
22
22
29
29
37
37
44
44
52
52
59
59
66
66
Number of lamps: Lumens per lamp:Input watts:Distribution:E�ciency:Photometric type:
Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:
Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:
22254.9
Direct-Indirect5.7
C
RectangleFeet0.210.370.37
0.860.910.75
© 2014 EUREKA LIGHTINGwww.eurekalighting.com
341X-2FL-LED402X2Equinox RD or SQ - FLOOD BEAM - 4000K - 2x2W
Equinox RD & SQ
Photometric Report
0 - 18090 - 270
anglescd
0.0 10.0 20.0
30.0
40.0
50.0
60.0
70.080.0
90.0
100.0110.0
120.0
130.0
140.0
150.0
160.0170.0180.0
0
8
8
17
17
25
25
33
33
41
41
50
50
58
58
66
66
74
74
Number of lamps: Lumens per lamp:Input watts:Distribution:E�ciency:Photometric type:
Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:
Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:
22254.9
Direct-Indirect5.7
C
RectangleFeet0.210.370.37
0.860.910.75
© 2014 EUREKA LIGHTINGwww.eurekalighting.com
341X-2FL-LED402X2Equinox RD or SQ - FLOOD BEAM - 4000K - 2x2W
Equinox RD & SQ
Photometric Report
0 - 18090 - 270
anglescd
0.0 10.0 20.0
30.0
40.0
50.0
60.0
70.080.0
90.0
100.0110.0
120.0
130.0
140.0
150.0
160.0170.0180.0
0
8
8
17
17
25
25
33
33
41
41
50
50
58
58
66
66
74
74
Number of lamps: Lumens per lamp:Input watts:Distribution:E�ciency:Photometric type:
Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:
Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:
22254.9
Direct-Indirect5.7
C
RectangleFeet0.210.370.37
0.860.910.75
© 2014 EUREKA LIGHTINGwww.eurekalighting.com
341X-2FL-LED402X2Equinox RD or SQ - FLOOD BEAM - 4000K - 2x2W
Equinox RD & SQ
Photometric Report
0 - 18090 - 270
anglescd
0.0 10.0 20.0
30.0
40.0
50.0
60.0
70.080.0
90.0
100.0110.0
120.0
130.0
140.0
150.0
160.0170.0180.0
0
8
8
17
17
25
25
33
33
41
41
50
50
58
58
66
66
74
74
Installation Instructions
225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com
INSTALLATIONMAINTENANCE
3411Equinox
Wet/Dry Location Wall FixtureApplique emplacement mouillé/sec
INSTALLATIONAVANT DE COMMENCER, DESSERRER LES 2 VIS DE PRESSION [E] POUR ENLEVER LE COUVERCLE [F]. SÉPARER LA PLAQUE RONDE [C] DE LA PLAQUE UNIVERSELLE [A] EN RETIRANT LES VIS [D].
1- INSTALLER LA PLAQUE UNIVERSELLE [A] AVEC DEUX VIS #8-32 (NON INCLUSES) ET FIXER LE FIL VERT À LA BOÎTE DE CONNEXION.
2- POUR UNE INSTALLATION DANS UN ENVIRONNEMENT MOUILLÉ, COLLER LE JOINT D’ÉTANCHÉITÉ [B] À L’ENDOS DE LA PLAQUE RONDE [C].
3- CONNECTER LES FILS DU LUMINAIRE À L’AIDE DE DEUX CONNECTEURS (NON INCLUS) EN RESPECTANT LES INDICATIONS INSCRITES SUR L’ÉTIQUETTE DU PILOTE (LE PILOTE PEUT DIFFÉRER DE CELUI ILLUSTRÉ). IMPORTANT: NE PAS MODIFIER LES CONNECTIONS À L’INTÉRIEUR DU LUMINAIRE.
4- FIXER LA STRUCTURE [C] À LA PLAQUE UNIVERSELLE [A] À L’AIDE DES VIS [D].IMPORTANT: ORIENTER LA LUMIÈRE EN DIRECTION VOULUE. REMPLIR DE SILICONE (NON INCLUS) TOUTE OUVERTURE ENTRE LE MUR ET LA PLAQUE RONDE [B].
5- INSÉRER L’ANNEAU DE SILICONE [G]. ORIENTER LE COUVERCLE [F] POUR QUE LES OUVERTURES SOIENT ALIGNÉES AVEC LES DEL ET FIXER CELUI-CI AVEC LES DEUX VISDE PRESSION [E].
5a- AJUSTER LE COUVERCLE [F] POUR QUE LES DEUX FAISCEAUX DE LUMIÈRE SOIENT ALIGNÉS VERTICALEMENT.
INSTALLATIONUNTIGHTEN THE TWO SET SCREWS [E] THEN TAKE OFF THE COVER [F]. FREE THE FRAME [C] FROM THE UNIVERSAL PLATE [A] BY REMOVING THE TWO SCREWS [D].
1- INSTALL THE UNIVERSAL PLATE [A] WITH TWO #8-32 SCREWS (NOT SUPPLIED) AND GROUND THE GREEN WIRE TO THE JUNCTION BOX.
2-FOR INSTALLATION IN A WET ENVIRONMENT, AFFIX THE SILICONE GASKET [B] TO THE BACK OF THE STRUCTURE [C].
3- CONNECT THE FIXTURE USING 2 WIRE NUTS (NOT SUPPLIED) FOLLOWING THE INDICATIONS ON THE ELECTRONIC DRIVER (THE DRIVER SHAPE CAN VARY FROM THE ILLUSTRATION). IMPORTANT: DO NOT ALTER THE CONNECTIONS INSIDE THE FIXTURE.
4- FIX THE STRUCTURE [C] TO THE UNIVERSAL PLATE [A] USING THE SCREWS [D].IMPORTANT: ALIGN THE LIGHT IN DESIRED DIRECTION.FILL ANY GAPS BETWEEN WALL AND BACKPLATE [A] WITH SILICONE CAULKING (NOT SUPPLIED)
5-INSTALL THE SILICONE GASKET RING [G]. ALIGN COVER [F] SO OPENINGS ARE CORRECTLY POSITIONED OVER THE LED AND SCREW IT IN PLACE USING THE TWO SET SCREWS [E].
5a - ROTATE HORIZONTALLY THE COVER [F] SO THE TOP AND BOTTOM LIGHT BEAMS ARE ALIGNED VERTICALLY.
3
E
G
F
BC
D
4
5
2
A
1
IP 65 UL WET
5a
REMOVE THE FILM FROMTHE GASKET BEFORE PROCEEDINGTO THE INSTALLATION.
RETIRER LA PELLICULE DU JOINTD’ÉTANCHÉITÉ AVANT DE PROCÉDERÀ L’INSTALLATION.
Equinox 3411|3412