Nokia Siemens Networks WCDMA RNC Rel. RN6.0, Site Documentation, Issue 01
Equipment Lists for RNC450
DN0639624
Issue 03Approval Date 2011-01-06
Confidential
2 DN0639624Issue 03
Equipment Lists for RNC450
Id:0900d80580819cdbConfidential
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2011. All rights reserved
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.
The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-satzes.
DN0639624 3
Equipment Lists for RNC450
Id:0900d80580819cdbConfidential
Table of contentsThis document has 44 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1 About Equipment lists for RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1 Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.2 Notations used in equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1 RNAC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1.1 Subracks, fan trays, and cable supporting shelves to the front . . . . . . . 112.1.2 Subracks for back interfaces, panels, and cable supporting shelves to the
rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.1.3 Back interface units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.1.4 Equipment kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.2 RNAC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 162.3 RNAC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 212.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3 RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233.1 RNBC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233.1.1 Subracks, fan trays, and cable supporting shelves to the front . . . . . . . 233.1.2 Subracks for back interfaces and cable supporting shelves to the rear. 233.1.3 Equipment kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243.1.4 Grounding set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243.2 RNBC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 263.3 RNBC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 313.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4 NIS1P, NIS1 and NIP1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 324.1 NIP1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324.2 NIS1P and NIS1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324.2.1 Equipping NIS1P and NIS1 units to RNC450 step 1 . . . . . . . . . . . . . . . 334.2.2 Equipping NIS1P and NIS1 units to RNC450 step 2 . . . . . . . . . . . . . . . 354.2.3 Equipping NIS1P and NIS1 units to RNC450 step 3 . . . . . . . . . . . . . . . 37
5 Cabinet stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4 DN0639624
Equipment Lists for RNC450
Id:0900d80580819cdbConfidential
List of figuresFigure 1 Notations used in the equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Figure 2 Positions of CPSY-A, CPSY-B, and CPAL-A panels . . . . . . . . . . . . . . . 13Figure 3 BIE1T and BIE1C equipping principle with SRBI-C . . . . . . . . . . . . . . . . 14Figure 4 Functional units of the RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 5 Grounding between RNAC and RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . 25Figure 6 Functional units of the RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Figure 7 NIS1P, NIS1 and NIP1 equipping positions inRNC450 step 1 . . . . . . . . 33Figure 8 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2 . . . . . . . 35Figure 9 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3 . . . . . . . 37Figure 10 NIS1 1 equipping restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Figure 11 NIS1 3 equipping restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 12 IPA2800 cabinet; note that front and back sides are identical . . . . . . . . 41Figure 13 IPA2800 cabinet stickers; the stickers in the figure are attached to all cab-
inets except Network Element Name stickers and Marking strips . . . . . 42Figure 14 Stickers already attached on delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Figure 15 Product collection and disposal within the European Union . . . . . . . . . . 44
DN0639624 5
Equipment Lists for RNC450
Id:0900d80580819cdbConfidential
List of tablesTable 1 RNAC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Table 2 Subracks and fan trays to the front for the RNAC . . . . . . . . . . . . . . . . . 11Table 3 Subracks for back interfaces, panels, and cable supporting shelves for the
RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Table 4 Back interface units of the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Table 5 Equipment kit EQIK216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Table 6 Functional units, plug-in units, and memory modules of the RNAC . . . 17Table 7 Marking strips for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 8 Stickers for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 9 RNBC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Table 10 Subracks and fan trays to the front for the RNBC . . . . . . . . . . . . . . . . . 23Table 11 Subracks for back interfaces and cable supporting shelves for RNBC . 23Table 12 Equipment kit EQIS216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Table 13 Grounding sets for RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Table 14 Functional units and plug-in units of the RNBC . . . . . . . . . . . . . . . . . . 27Table 15 Marking strips for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 16 Stickers for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 17 STM-1/OC-3 ATM interfaces in RNC450 . . . . . . . . . . . . . . . . . . . . . . . 32Table 18 Number of units in mixed configurations of 2N redundant and non-redun-
dant units in RNC450 step 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Table 19 Number of units in mixed configurations of 2N redundant and non-redun-
dant units in RNC450 step 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Table 20 Number of units in mixed configurations of 2N redundant and non-redun-
dant units in RNC450 step 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6 DN0639624
Equipment Lists for RNC450
Id:0900d80580819cdbConfidential
DN0639624 7
Equipment Lists for RNC450 Summary of changes
Id:0900d8058081d12bConfidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Changes between issue 2-2 and 03RRMU and NEMU related information is deleted. CCP1D-A, HDS-C and ESA40 related information is added.
Equipping rules are updated. HDS-C is one slot plug-in unit and HDS-B is two slots pulgin unit, so F15 is only occupied when use HDS-B.
Changes between issue2-1 and 2-2Section NIS1P, NIS1 and NIP1 equipping rules updated: equipping rules and restric-tions are described for each RNC450 capacity step separately.
Changes between issue 2-0 and 2-1A new CPU variant CCP18-C is taken into use. CCP18-A is still used with OMU, because the USB port is needed for backup purposes.
8 DN0639624
Equipment Lists for RNC450
Id:0900d80580836038Confidential
About Equipment lists for RNC450
1 About Equipment lists for RNC450Equipment lists for RNC450 provides a list of cabinet mechanics, subracks, and plug-in units installed in the RNAC and RNBC cabinets for RNC450. Sections RNAC cabinet and RNBC cabinet include the physical positions of the hardware items inside the cab-inets.
RNC450 features three capacity steps:
• RNC450 capacity step 1 = RNC450/150 (RNAC) • RNC450 capacity step 2 = RNC450/300 (RNBC Subrack 1–2) • RNC450 capacity step 3 = RNC450/450 (RNBC Subrack 3–4)
1.1 Related documentsCable ListsDetailed information on cabling and individual cables can be found in Cable Lists for RNC450.
Engineering DescriptionBasic information on, for example, RNC installation planning can be found in Engineer-ing for Radio Network Controller (RNC).
Installation ManualDetailed information on the installation of RNC hardware, see Installing the MGW and RNC.
Cabinet Interfaces and CablingDetailed information on cabinet interfaces and cabling can be found in Cabinet Inter-faces and External Cables of MGW and RNC.
1.2 Notations used in equipment listsThe equipment lists contain the columns shown in the figure below, with their contents described in the list which follows.
DN0639624 9
Equipment Lists for RNC450 About Equipment lists for RNC450
Id:0900d80580836038Confidential
Figure 1 Notations used in the equipment lists
The positions are presented in the form of a table. The figure shows only one table type, but tables can have the following columns:
• Side indicates the side on which the unit in question is equipped. (F = Front, B = Back)
• Mounting hole no. indicates the number of the mounting hole used for the installation of the particular unit.
• Subrack indicates the subrack position of a specific unit. • Position shows the coordinates inside the rack and the number of the slot in the car-
tridge. • ID (Identification) shows the identification code of the cabinet, cartridge, plug-in unit,
or accessory. • Name shows the abbreviated name of the hardware product for the identification
code in the previous column.
IPA2800 RNC / MGW cabinet,front view
DN05158674
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
38
SUBRACK 3front view
Plug-in unit position number
1
SUBRACK 1
SUBRACK 2
SUBRACK 3
SUBRACK 4
Position ID Name FU Notes
F01 C105546 CDSP-C DMCU 4
F02 C105546 CDSP-C DMCU 5
F03 C109093 ICSU 4
1
Subrack 3
CCP18-A Mounted2GB memoryincluded
10 DN0639624
Equipment Lists for RNC450
Id:0900d80580836038Confidential
About Equipment lists for RNC450
• PIU indicates the name of the plug-in unit in question. • FU (Functional Unit) shows the name and index number of the functional unit
equipped into the cartridge in this particular position. • Use shows the name and number of the functional unit, which contains the plug-in
units listed below and equipped in this cartridge position. • Notes column includes additional information.
When two or more different hardware products can be equipped in the same position, the identification code and name of each type is given.
DN0639624 11
Equipment Lists for RNC450 RNAC cabinet
Id:0900d8058081d12dConfidential
2 RNAC cabinetThis section lists all the equipment mechanics for the RNAC cabinet.
2.1 RNAC cabinet mechanics
2.1.1 Subracks, fan trays, and cable supporting shelves to the front
Equipping Side Mounting hole no.
ID Name Use
C109740 EC216 Cabinet
F C109742 DR216 Door right
F C109743 DL216 Door left
B C109742 DR216 Door right
B C109743 DL216 Door left
F C110052 CPD120-A Power distribution and fuse unit
F C110052 CPD120-A Power distribution and fuse unit
F C110505 CAIND-A Cabinet Alarm indi-cator
C110076 SCP216 Side cover plate
C110076 SCP216 Side cover plate
Table 1 RNAC cabinet mechanics
Side Mounting hole no.
ID Name Use
F 53 C109979 SRA3 Subrack
F 49 C109730 FTRA-B Fan tray
F 37 C109979 SRA3 Subrack
F 33 C109730 FTRA-B Fan tray
F 21 C109979 SRA3 Subrack
F 17 C109730 FTRA-B Fan tray
F 5 C109979 SRA3 Subrack
F 1 C109730 FTRA-B Fan tray
Table 2 Subracks and fan trays to the front for the RNAC
12 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12dConfidential
RNAC cabinet
2.1.2 Subracks for back interfaces, panels, and cable supporting shelves to the rear
Side Mounting hole no./ Position
ID Name Use Notes
B 53 C110568 SRBI-C Subrack for back inter-faces
B 50 C110730 CS216-A Cable supporting shelf
B 50.01 C110551 CPSY-A Connector panel for syn-chronisation
B 50.10 C110747 CPSY-B Connector panel for syn-chronisation
B 37 C110568 SRBI-C Subrack for back inter-faces
B 35 C110730 CS216-A Cable supporting shelf
B 35.01 C110487 CPAL-A Connector panel for alarms
B 21 C105864 CS186-B Cable supporting shelf
B 21 C110568 SRBI-C Subrack for back inter-faces
B 5 C110568 SRBI-C Subrack for back inter-faces
B 1 C105864 CS186-B Cable supporting shelf
Table 3 Subracks for back interfaces, panels, and cable supporting shelves for the RNAC
DN0639624 13
Equipment Lists for RNC450 RNAC cabinet
Id:0900d8058081d12dConfidential
Figure 2 Positions of CPSY-A, CPSY-B, and CPAL-A panels
2.1.3 Back interface unitsBIE1T and BIE1C are optional back interface units for RNAC. They are used with NIP1 0.
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
CPSY-A
CPAL-A
CPSY-B
DN05160803
14 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12dConfidential
RNAC cabinet
Figure 3 BIE1T and BIE1C equipping principle with SRBI-C
Subrack Position ID PIU Name
3.0B 15 C103060 BIE1T Back interface unit for E1, T1 and JT1
C103030 BIE1C Back Interface unit for E1
Table 4 Back interface units of the RNAC
SMB connectorSingle or multicoaxial cable
RJ-45 connectorMulticable
BIE1T
SRBI-C
NIP1
DN70200648BIE1C
SRBI-C
NIP1
DN0639624 15
Equipment Lists for RNC450 RNAC cabinet
Id:0900d8058081d12dConfidential
2.1.4 Equipment kits
The EQIK216 equipment kit contains the following items:
• washers • static control wrist strap • screws • pink minigrip bags • locking pegs • cable ties
ID Name Use
C110720 EQIK216 Installation set for RNAC
Table 5 Equipment kit EQIK216
16 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12dConfidential
RNAC cabinet
2.2 RNAC functional units and plug-in units
Figure 4 Functional units of the RNAC cabinet
Equipping rulesCapacity step 1 includes all RNAC subracks. All units except the interface units (NIS1P, NIS1 and NIP1) are equipped in index order, starting from the lowest index. For equip-ping rules of the interface units, see section NIS1P, NIS1 and NIP1 equipping rules.
1. Install all units except NIS1P, NIS1 and NIP1 0 in index order, starting from the unit indexed as 0.
DN0639624 17
Equipment Lists for RNC450 RNAC cabinet
Id:0900d8058081d12dConfidential
2. Install optional NIP1 0, if used.3. Install 2N redundant NIS1P pairs and non-redundant NIS1 units. See the equipping
rules and restrictions in section NIS1P, NIS1 and NIP1 equipping rules.4. Install cover plates for the slots that remain empty.5. If CCP1D-A is used for OMU or RSMU also redundant unit must be CCP1D-A. If
CCP1D-A is used for OMU the replacement of HDS-B to HDS-C is mandatory and standalone OMS should be used instead of integrated OMS.
The following units are ordered separately:
• Optional second ESA40-A/ESA24 • Optional NIP1 0 • NIS1P/NIS1 2–3 • NIS1P 10-11
Position ID Name FU Notes
Subrack 1
F01
F02
C110899
C100580
SF10E
/SF10
SFU 0
F03 C110830 CDSP-DH DMCU 0
F04 C110830 CDSP-DH DMCU 1
F05 C111417
C108427
ESA40-A
ESA24
SWU 0
F06 C11054 MCP18-B OMS Mounted 4GB memory included
F07 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 22 1)
F08 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
RSMU 0 1)
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 0
F10 C109472 PD30 – Subrack power
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 1
F12 C109047 AL2S-D A2SU 0
F13 C109047 AL2S-D A2SU 1
Table 6 Functional units, plug-in units, and memory modules of the RNAC
18 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12dConfidential
RNAC cabinet
F14
F15
C111977
C109941
HDS-C
HDS-B
WDU 0
HDD 0
HDS-C is used with HDS14-A(P01113). HDS-B is used with WDW147(P01118) or WDW 73(P01098).
HDS-C is one slot plug-in unit and HDS-B is two slots pulg-in unit, so F15 is only occupied when use HDS-B.
A = OMU
B = OMS (closest to front panel)
F16 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
OMU 0 1)
F17 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 0 1)
F18 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 1 1)
F19 C08986 TSS3 TBU 0
F38 C71700 TBUF TBU 1
Subrack 2
F01
F02
C110899
C100580
SF10E
/SF10
SFU 1
F03 C110830 CDSP-DH DMCU 2
F04 C110830 CDSP-DH DMCU 3
F05 C111417
C108427
ESA40-A
ESA24
SWU 1 Optional
F06 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 0 1)
F07 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 23 1)
F08 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
RSMU 1 1)
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 2
F10 C109472 PD30 – Subrack power
Position ID Name FU Notes
Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)
DN0639624 19
Equipment Lists for RNC450 RNAC cabinet
Id:0900d8058081d12dConfidential
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 3
F12 C109047 AL2S-D A2SU 2
F13
F14
C111977
C109941
HDS-C
HDS-B
WDU 1
HDD 1
HDS-C is used with HDS14-A(P01113). HDS-B is used with WDW147(P01118) or WDW 73(P01098).
HDS-C is one slot plug-in unit and HDS-B is two slots pulg-in unit, so F13 is only occupied when use HDS-B.
A = OMU
B = OMS (closest to front panel)
F15 C100880 EHAT EHU
F16 C109093 CCP18-A OMU 1 1)
F17 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 2 1)
F18 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 3 1)
F19 C71700 TBUF TBU 0
F38 C08986 TSS3 TBU 1
Subrack 3
F01 C110830 CDSP-DH DMCU 4
F02 C110830 CDSP-DH DMCU 5
F03 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 4 1)
F04 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 5 1)
F05 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 6 1)
F06 C110830 CDSP-DH DMCU 6
F07 C110830 CDSP-DH DMCU 7
F08 C110830 CDSP-DH DMCU 8
Position ID Name FU Notes
Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)
20 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12dConfidential
RNAC cabinet
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 4
F10 C109472 PD30 – Subrack power
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 5
F12 C109047 AL2S-D A2SU 3
F13 C110830 CDSP-DH DMCU 9
F14 C110830 CDSP-DH DMCU 10
F15 C100790
C100610
NI16P1A
NI4S1-B
NIP1 0
NIS1P 10
Ordered separately
NIP1 0 equipping requires cabling changes and the adding of BIE1T/C back interface panel
NIS1P 10 can be equipped either in RNAC or RNBC.
If NIS1 3 is configured, NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured.
F16 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 1 1)
F17 C100610 NI4S1-B NIS1P 0
NIS1 0
Included in capacity step RNC450/150
F18 C100610 NI4S1-B NIS1P 2
NIS1 2
Ordered separately
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Subrack 4
F01 C110830 CDSP-DH DMCU 11
F02 C110830 CDSP-DH DMCU 12
F03 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 7 1)
F04 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 8 1)
F05 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 9 1)
Position ID Name FU Notes
Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)
DN0639624 21
Equipment Lists for RNC450 RNAC cabinet
Id:0900d8058081d12dConfidential
2.3 RNAC cabinet stickers and marking stripsSee Figure IPA2800 stickers in section Cabinet stickers for the locations of the marking strips and stickers.
F06 C110830 CDSP-DH DMCU 13
F07 C110830 CDSP-DH DMCU 14
F08 C110830 CDSP-DH DMCU 15
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 6
F10 C109472 PD30 – Subrack power
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 7
F12 C109047 AL2S-D A2SU 4
F13 C110830 CDSP-DH DMCU 16
F14 C110830 CDSP-DH DMCU 17
F15 C100610 NI4S1-B NIS1P 11 Ordered separately
NIS1P 11 can be equipped either in RNAC or RNBC.
If NIS1 3 is configured, NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured.
F16 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 2 1)
F17 C100610 NI4S1-B NIS1P 1
NIS1 1
Included in capacity step RNC450/150
If NIS1 1 is configured, NIS1P/NIS1 8 and NIS1P 9 in RNBC cannot be con-figured.
F18 C100610 NI4S1-B NIS1P 3
NIS1 3
Ordered separately
If NIS1 3 is configured, NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured.
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
1) CCP1D-A is mounted 4GB memory. CCP18-A and CCP18-C is mounted 2GB?
Position ID Name FU Notes
Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)
22 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12dConfidential
RNAC cabinet
2.3.1 Marking strips
2.3.2 Stickers
Position Name Use
F 1 RNAC F1 IPA2800 Marking Strip for subrack 1
F 2 RNAC F2 IPA2800 Marking Strip for subrack 2
F 3 RNAC F3 IPA2800 Marking Strip for subrack 3
F 4 RNAC F4 IPA2800 Marking Strip for subrack 4
Table 7 Marking strips for the RNAC
Position Code Name Use Notes
F Name sticker RNAC (window)
Network Element Sticker
B Name sticker RNAC Network Element Sticker
F Identifier sticker sheet Subrack position number sticker
F ESD sticker Each subrack 4 pcs
T Note sticker
T UB 1 sticker Power sticker
T UB 2 sticker Power sticker
HDD (OMS) sticker Identification sticker for OMS hard disk on HDS-C
2 pcs
WDU (OMU) sticker Identification sticker for OMU hard disk on HDS-C
2 pcs
Table 8 Stickers for the RNAC
DN0639624 23
Equipment Lists for RNC450 RNBC cabinet
Id:0900d8058081d12fConfidential
3 RNBC cabinetThis section lists all the equipment mechanics for the RNBC cabinet.
3.1 RNBC cabinet mechanics
3.1.1 Subracks, fan trays, and cable supporting shelves to the front
3.1.2 Subracks for back interfaces and cable supporting shelves to the rear
Equipping Side Mounting hole no.
ID Name Use
C109740 EC216 Cabinet
F C109742 DR216 Door right
F C109743 DL216 Door left
B C109742 DR216 Door right
B C109743 DL216 Door left
F C110052 CPD120-A Power distribution and fuse unit
F C110052 CPD120-A Power distribution and fuse unit
Table 9 RNBC cabinet mechanics
Equipping Side Mounting hole no.
ID Name Use
F 53 C109979 SRA3 Subrack
F 49 C109730 FTRA-B Fan tray
F 37 C109979 SRA3 Subrack
F 33 C109730 FTRA-B Fan tray
F 21 C109979 SRA3 Subrack
F 17 C109730 FTRA-B Fan tray
F 5 C109979 SRA3 Subrack
F 1 C109730 FTRA-B Fan tray
Table 10 Subracks and fan trays to the front for the RNBC
Side Mounting hole no.
ID Name Use
B 53 C110568 SRBI-C Subrack for back interfaces
B 50 C105864 CS186-B Cable supporting shelf
Table 11 Subracks for back interfaces and cable supporting shelves for RNBC
24 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12fConfidential
RNBC cabinet
3.1.3 Equipment kits
The EQIS216 equipment kit contains the following items:
• washers • static control wrist strap • screws • pink minigrip bags • locking pegs • cable ties
3.1.4 Grounding setThe grounding cables between RNAC and RNBC cabinets needs to be installed at the site.
The grounding set contains:
• 4 pcs grounding cables • washers • screws
B 37 C110568 SRBI-C Subrack for back interfaces
B 35 C105864 CS186-B Cable supporting shelf
B 21 C110568 SRBI-C Subrack for back interfaces
B 21 C105864 CS186-B Cable supporting shelf
B 5 C110568 SRBI-C Subrack for back interfaces
B 1 C105864 CS186-B Cable supporting shelf
Side Mounting hole no.
ID Name Use
Table 11 Subracks for back interfaces and cable supporting shelves for RNBC (Cont.)
ID Name Use
C110721 EQIS216 Installation set for RNBC
Table 12 Equipment kit EQIS216
ID Name Use Notes
C109878 Grounding set Grounding RNAC to RNBC EC216 to EC216
Table 13 Grounding sets for RNBC
DN0639624 25
Equipment Lists for RNC450 RNBC cabinet
Id:0900d8058081d12fConfidential
Figure 5 Grounding between RNAC and RNBCREAR SIDE OF CABINET DN0644085
EC216
EC216
26 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12fConfidential
RNBC cabinet
3.2 RNBC functional units and plug-in units
Figure 6 Functional units of the RNBC cabinet
Equipping rulesSubracks 1–2 form capacity step RNC450/300, subracks 3–4 is capacity step RNC450/450. NIS1P/NIS1 units are ordered separately as needed.
All units except the interface units (NIS1P, NIS1) are equipped in index order, starting from the lowest index. For equipping rules of the interface units, see section NIS1P, NIS1 and NIP1 equipping rules.
1. Install all units except NIS1P and NIS1 in index order, starting from the lowest index.2. Install 2N redundant NIS1P pairs and non-redundant NIS1 units. See the equipping
rules and restrictions in section NIS1P, NIS1 and NIP1 equipping rules.
RNBC
DN0624954 FRONT VIEW
ICS
U16
ICS
U17
ICS
U18
DM
CU
31
DM
CU
32
DM
CU
33
MX
U12
PD
30
MX
U13
A2S
U7
DM
CU
34
TB
U1
TB
U0
DM
CU
30
- DM
CU
36
DM
CU
35
NIS
1P
/N
IS1
8
NIS
1P
/N
IS1
10
GT
PU
6
ICS
U13
ICS
U14
ICS
U1
5
- DM
CU
26
DM
CU
27
MX
U10
PD
30
MX
U11
A2S
U6
DM
CU
28
TB
U1
TB
U0
DM
CU
25
- GT
PU
4
DM
CU
29
NIS
1P
5
NIS
1P
7
GT
PU
5
ICS
U10
ICS
U11
ICS
U12
DM
CU
19
DM
CU
20
DM
CU
21
MX
U8
PD
30
MX
U9
A2
SU
5
DM
CU
22
TB
U1
TB
U0
DM
CU
18
- DM
CU
24
DM
CU
23
NIS
1P
/N
IS1
4
NIS
1P
/N
IS1
6
GT
PU
3
ICS
U19
ICS
U20
ICS
U21
DM
CU
38
DM
CU
39
DM
CU
40
MX
U14
PD
30
MX
U1
5
A2S
U8
DM
CU
41
TB
U1
TB
U0
DM
CU
37
- DM
CU
43
DM
CU
42
NIS
1P
9
NIS
1P
11
GT
PU
7
DN0639624 27
Equipment Lists for RNC450 RNBC cabinet
Id:0900d8058081d12fConfidential
3. Install cover plates for the slots that remain empty.
Position ID Name FU Notes
Subrack 1
F01 — — —
F02 C110830 CDSP-DH DMCU 18
F03 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 10 1)
F04 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 11 1)
F05 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 12 1)
F06 C110830 CDSP-DH DMCU 19
F07 C110830 CDSP-DH DMCU 20
F08 C110830 CDSP-DH DMCU 21
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 8
F10 C109472 PD30 – Subrack power
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 9
F12 C109047 AL2S-D A2SU 5
F13 C110830 CDSP-DH DMCU 22
F14 C110830 CDSP-DH DMCU 23
F15 C110830 CDSP-DH DMCU 24
F16 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 3 1)
F17 C100610 NI4S1-B NIS1P 4
NIS1 4
Ordered separately
F18 C100610 NI4S1-B NIS1P 6
NIS1 6
Ordered separately
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Subrack 2
Table 14 Functional units and plug-in units of the RNBC
28 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12fConfidential
RNBC cabinet
F01 — — —
F02 C110830 CDSP-DH DMCU 25
F03 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 13 1)
F04 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 14 1)
F05 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 15 1)
F06 — — —
F07 C110830 CDSP-DH DMCU 26
F08 C110830 CDSP-DH DMCU 27
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 10
F10 C109472 PD30 – Subrack power
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 11
F12 C109047 AL2S-D A2SU 6
F13 C110830 CDSP-DH DMCU 28
F14 C110830 CDSP-DH DMCU 29
F15 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 4 1)
F16 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 5 1)
F17 C100610 NI4S1-B NIS1P 5 Ordered separately
F18 C100610 NI4S1-B NIS1P 7 Ordered separately
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
Subrack 3
F01 — — —
F02 C110830 CDSP-DH DMCU 30
Position ID Name FU Notes
Table 14 Functional units and plug-in units of the RNBC (Cont.)
DN0639624 29
Equipment Lists for RNC450 RNBC cabinet
Id:0900d8058081d12fConfidential
F03 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 16 1)
F04 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 17 1)
F05 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 18 1)
F06 C110830 CDSP-DH DMCU 31
F07 C110830 CDSP-DH DMCU 32
F08 C110830 CDSP-DH DMCU 33
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 12
F10 C109472 PD30 – Subrack power
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 13
F12 C109047 AL2S-D A2SU 7
F13 C110830 CDSP-DH DMCU 34
F14 C110830 CDSP-DH DMCU 35
F15 C110830 CDSP-DH DMCU 36
F16 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 6 1)
F17 C100610 NI4S1-B NIS1P 8
NIS1 8
Ordered separately
When NIS1 1 is configured, the NIS1P/NIS1 8 and NIS1P 9 in RNBC cannot be configured.
F18 C100610 NI4S1-B NIS1P 10
NIS1 10
Ordered separately
NIS1P 10 and NIS1P 11 can be equipped either in RNAC or RNBC. If they are configured in RNAC, cabling changes are needed.
When NIS1 3 is configured, the NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be con-figured.
F19 C71700 TBUF TBU 0
Position ID Name FU Notes
Table 14 Functional units and plug-in units of the RNBC (Cont.)
30 DN0639624
Equipment Lists for RNC450
Id:0900d8058081d12fConfidential
RNBC cabinet
F38 C71700 TBUF TBU 1
Subrack 4
F01 — — —
F02 C110830 CDSP-DH DMCU 37
F03 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 19 1)
F04 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 20 1)
F05 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
ICSU 21 1)
F06 C110830 CDSP-DH DMCU 38
F07 C110830 CDSP-DH DMCU 39
F08 C110830 CDSP-DH DMCU 40
F09 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 14
F10 C109472 PD30 – Subrack power
F11 C109700
C105866
C100590
MX622-D
MX622-C
MX622-B
MXU 15
F12 C109047 AL2S-D A2SU 8
F13 C110830 CDSP-DH DMCU 41
F14 C110830 CDSP-DH DMCU 42
F15 C110830 CDSP-DH DMCU 43
F16 C111943
C111034
C109093
CCP1D-A
CCP18-C
CCP18-A
GTPU 7 1)
F17 C100610 NI4S1-B NIS1P 9 Ordered separately
When NIS1 1 is configured, the NIS1P/NIS1 8 and NIS1P 9 in RNBC cannot be configured.
Position ID Name FU Notes
Table 14 Functional units and plug-in units of the RNBC (Cont.)
DN0639624 31
Equipment Lists for RNC450 RNBC cabinet
Id:0900d8058081d12fConfidential
3.3 RNBC cabinet stickers and marking stripsSee Figure IPA2800 stickers in Section Cabinet stickers for the locations of the marking strips and stickers.
3.3.1 Marking strips
3.3.2 Stickers
F18 C100610 NI4S1-B NIS1P 11 Ordered separately
NIS1P 10 and NIS1P 11 can be equipped either in RNAC or RNBC. If they are configured in RNAC, cabling changes are needed.
When NIS1 3 is configured, the NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be con-figured.
F19 C71700 TBUF TBU 0
F38 C71700 TBUF TBU 1
1) CCP1D-A is mounted 4GB memory. CCP18-A and CCP18-C is mounted 2GB?
Position ID Name FU Notes
Table 14 Functional units and plug-in units of the RNBC (Cont.)
Position Name Use
F 1 RNBC F1 IPA2800 Marking Strip for subrack 1
F 2 RNBC F2 IPA2800 Marking Strip for subrack 2
F 3 RNBC F3 IPA2800 Marking Strip for subrack 3
F 4 RNBC F4 IPA2800 Marking Strip for subrack 4
Table 15 Marking strips for the RNBC
Position Name Use Notes
F Name sticker RNBC (window)
Network Element Sticker
B Name sticker RNBC Network Element Sticker
F Identifier sticker sheet
Subrack position number sticker
F ESD sticker Each subrack 4 pcs
T Note sticker
T UB 1 sticker Power sticker
T UB 2 sticker Power sticker
Table 16 Stickers for the RNBC
32 DN0639624
Equipment Lists for RNC450
Id:0900d8058082a3cbConfidential
NIS1P, NIS1 and NIP1 equipping rules
4 NIS1P, NIS1 and NIP1 equipping rulesThis section describes the equipping rules for interface units NIS1P, NIS1 and NIP1 in RNC450.
4.1 NIP1 equipping rulesRNC450 features one optional NIP1 0 unit. It can be equipped as an alternative to NIS1P 10 in RNAC subrack 3 slot 15.
When NIP1 0 is equipped, cabling changes are needed and the BIE1T/BIE1C back interface needs to equipped at the rear of the subrack. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 6 Adding optional NIP1 unit to RNC450.
4.2 NIS1P and NIS1 equipping rulesThe Network Interface Unit STM-1 (NI4S1-B) provides the RNC high bandwidth STM-1/OC-3 ATM interfaces. The unit might be configured either with 2N equipment protec-tion or without 2N equipment protection. When configured with 2N equipment protection the functional unit name is NIS1P. When configured without 2N equipment protection the functional unit name is NIS1.
Non-redundant NIS1 and 2N redundant NIS1P units can be mixed in the same network element. The number of units in mixed configuration is limited by the number of SFU ports available for the STM-1 interface units.
Number and type of STM-1/OC-3 interfaces and units in RNC450Table 11 STM-1/OC-3 ATM interfaces in RNC450 displays the type, and the number of interfaces supported by various RNC450 configurations.
Configuration Max number of unprotected units
Max number of 2N protected units
Number of unpro-tected interfaces (NIS1)
Number of pro-tected interfaces (NIS1P)
RNC450 step 1 4 4 or 61 (2 or 3 pairs) 16 8+8 or 12+12 1
RNC450 step 2 6 6 (3 pairs) 24 16+16 or 20+202
RNC450 step 3 12 12 (6 pairs) 24 24+24
1 6 units and 12+12 interfaces applies only if NIP1 is not used.2 10 units and 20+20 interfaces applies only if NIP1 is not used.
Table 17 STM-1/OC-3 ATM interfaces in RNC450
DN0639624 33
Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules
Id:0900d8058082a3cbConfidential
4.2.1 Equipping NIS1P and NIS1 units to RNC450 step 1Figure 2 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 1 shows the correct locations for NIx1x units.
Figure 7 NIS1P, NIS1 and NIP1 equipping positions inRNC450 step 1
Table 12 Number of units in mixed configurations of 2N redundant and non-redundant units in RNC450 step 1 describes how many units can be configured as 2N redundant when also non-redundant units are used, and vice versa.
DN70392866
RNAC
NIS
1P
0/
NIS
10
NIS
1P
2/N
IS1
2
NIS
1P
1/
NIS
11
NIS
1P
3/
NIS
13
NIS
1P
10
/N
IP1
0N
IS1P
11
Optionalequippingpositions forNIS1P 10-11in RNAC,if NIP1 0 is notequipped
Equippingposition foroptionalNIP1 0
34 DN0639624
Equipment Lists for RNC450
Id:0900d8058082a3cbConfidential
NIS1P, NIS1 and NIP1 equipping rules
The number of units in mixed configuration is limited by the number of SFU ports avail-able for the STM-1 interface units. The equipping restrictions in RNC450 step 1 are:
• When NIS1 3 is configured, the NIS1P 10 and NIS1P 11 cannot be configured. See, figure 6 NIS1 3 equipping restriction.
• NIS1P 10 and NIS1P 11 can be equipped either in RNAC (optional) or RNBC (default). If they are equipped in RNAC, cabling changes are needed. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P and NIS1 units to RNC450
Non-redundant NIS1 units
No. of units
0 1 2 3 4 5 6
No. of inter-faces
0 4 8 12 16 20 24
2N redundant NIS1P units
0 pair 0+0 x x x x x - -
1 pair 4+4 x x x x - - -
2 pair 8+8 x x x - - - -
3 pair 12+12 x - - - - - -
Table 18 Number of units in mixed configurations of 2N redundant and non-redun-dant units in RNC450 step 1
DN0639624 35
Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules
Id:0900d8058082a3cbConfidential
4.2.2 Equipping NIS1P and NIS1 units to RNC450 step 2Figure 3 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2 shows the correct locations for NIx1x units.
Figure 8 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2
Table 13 Number of units in mixed configurations of 2N redundant and non-redundant units in RNC450 step 2 describes how many units can be configured as 2N redundant when also non-redundant units are used, and vice versa.
DN70392893
RNAC RNBC
NIS
1P
0/
NIS
10
NIS
1P
2/N
IS1
2
NIS
1P
1/N
IS1
1
NIS
1P
3/
NIS
13
NIS
1P
4/
NIS
14
NIS
1P
6/
NIS
16
NIS
1P
5
NIS
1P
7
NIS
1P
10
/N
IP1
0N
IS1P
11
Optionalequippingpositions forNIS1P 10-11in RNAC,if NIP1 0 is notequipped
NIS1P 5 and 7units are equippedonly when the unitsare configuredwith 2n redundancy
Equippingposition foroptionalNIP1 0
36 DN0639624
Equipment Lists for RNC450
Id:0900d8058082a3cbConfidential
NIS1P, NIS1 and NIP1 equipping rules
The number of units in mixed configuration is limited by the number of SFU ports avail-able for the STM-1 interface units. The equipping restrictions in RNC450 step 2 are:
• When NIS1 3 is configured, the NIS1P 10 and NIS1P 11 cannot be configured. See figure 6 NIS1 3 equipping restriction.
• NIS1P 10 and NIS1P 11 can be equipped either in RNAC (optional) or RNBC (default). If they are configured in RNAC, cabling changes are needed. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P and NIS1 units to RNC450.
Non-redundant NIS1 units
No. of units
0 1 2 3 4 5 6
No. of interfaces
0 4 8 12 16 20 24
2N redundant NIS1P units
0 pair 0+0 x x x x x x x
1 pair 4+4 x x x x x x -
2 pair 8+8 x x x x x - -
3 pair 12+12 x x x - - - -
4 pair 16+16 x - - - - - -
5 pair 20+20 x - - - - - -
Table 19 Number of units in mixed configurations of 2N redundant and non-redun-dant units in RNC450 step 2
DN0639624 37
Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules
Id:0900d8058082a3cbConfidential
4.2.3 Equipping NIS1P and NIS1 units to RNC450 step 3Figure 4 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3 shows the correct locations for NIx1x units.
Figure 9 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3
Table 14 Number of units in mixed configurations of 2N redundant and non-redundant units in RNC450 step 3 describes, how many units can be configured as 2N redundant when also non-redundant units are used, and vice versa.
DN70347799
RNAC RNBC
NIS
1P
0/
NIS
10
NIS
1P
2/N
IS1
2
NIS
1P
1/N
IS1
1
NIS
1P
3/
NIS
13
NIS
1P
4/
NIS
14
NIS
1P
6/
NIS
16
NIS
1P
5
NIS
1P
7
NIS
1P
8/N
IS1
8
NIS
1P
10
/N
IS1
10
NIS
1P
9
NIS
1P
11
NIS
1P
10
/N
IP1
0N
IS1P
11
Alternativeequippingpositions forNIS1P 10-11
NIS1P 5, 7, 9 and 11units are equippedonly when the unitsare configuredwith 2n redundancy
Equippingposition foroptionalNIP1 0
38 DN0639624
Equipment Lists for RNC450
Id:0900d8058082a3cbConfidential
NIS1P, NIS1 and NIP1 equipping rules
The number of units in mixed configuration is limited by the number of SFU ports avail-able for the STM-1 interface units. The equipping restrictions in RNC450 step 3 are:
• When NIS1 1 is configured, the NIS1P 8 and NIS1P 9 in RNBC cannot be config-ured. See figure 5 NIS1 1 equipping restriction.
• When NIS1 3 is configured, the NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured. See, figure 6 NIS1 3 equipping restriction.
• NIS1P 10 and NIS1P 11 can be equipped either in RNAC or RNBC. If they are con-figured in RNAC, cabling changes are needed. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P and NIS1 units to RNC450.
Non-redundant NIS1 units
No. of units
0 1 2 3 4 5 6
No. of inter-faces
0 4 8 12 16 20 24
2N redundant NIS1P units
0 pair 0+0 x x x x x x x
1 pair 4+4 x x x x x x -
2 pair 8+8 x x x x x - -
3 pair 12+12 x x x x - - -
4 pair 16+16 x x x - - - -
5 pair 20+20 x x - - - - -
6 pair 24+24 x - - - - - -
Table 20 Number of units in mixed configurations of 2N redundant and non-redun-dant units in RNC450 step 3
DN0639624 39
Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules
Id:0900d8058082a3cbConfidential
Figure 10 NIS1 1 equipping restrictionDN70347378
RNAC RNBC
NIS
1P
0/
NIS
10
NIS
1P
2/N
IS1
2
NIS
11
NIS
1P
3/
NIS
13
NIS
1P
4/
NIS
14
NIS
1P
6/
NIS
16
NIS
1P
5
NIS
1P
7
NIS
1P
8/N
IS1
8
NIS
1P
10
/N
IS1
10
NIS
1P
9
NIS
1P
11
NIS
1P
10
NIS
1P
11
If NIS1 1 isequipped,NIS1P 8-9cannot beequipped inRNBC
40 DN0639624
Equipment Lists for RNC450
Id:0900d8058082a3cbConfidential
NIS1P, NIS1 and NIP1 equipping rules
Figure 11 NIS1 3 equipping restrictionDN70399108
RNAC RNBC
NIS
1P
0/
NIS
10
NIS
1P
2/N
IS1
2
NIS
1P
1/
NIS
11
NIS
13
NIS
1P
4/
NIS
14
NIS
1P
6/
NIS
16
NIS
1P
5
NIS
1P
7
NIS
1P
8/N
IS1
8
NIS
1P
10
/N
IS1
10
NIS
1P
9
NIS
1P
11
NIS
1P
10
NIS
1P
11
If NIS1 3 isequipped,NIS1P 10-11cannot beequipped inRNAC or RNBC.
DN0639624 41
Equipment Lists for RNC450 Cabinet stickers
Id:0900d8058083603aConfidential
5 Cabinet stickers
Figure 12 IPA2800 cabinet; note that front and back sides are identical
Radio Network Controller
RNAC
IPA2800
DN01173112
42 DN0639624
Equipment Lists for RNC450
Id:0900d8058083603aConfidential
Cabinet stickers
Figure 13 IPA2800 cabinet stickers; the stickers in the figure are attached to all cabinets except Network Element Name stickers and Marking strips
ATTENTION!Observeprecautionsfor handlingelectrostaticsensitivedevices UL
THE EDGES OF
THE CABINET
MAY BE SHARP
WARNING
UL
(2 PCS)
CAMA
FOR DC SUPPLYFUSE VALUESREFER TOUSER MANUAL
NOTE
DN01173093
3:MARKING STRIP SR4
3:MARKING STRIP SR3
3:MARKING STRIP SR2
3:MARKING STRIP SR1
6:ESD STICKER(4 PCS)
SRA1 IDENTIFIER STICKER
2:NAME STICKER RNAC (2pcs)
1:NAME STICKER CAMA (2pcs)
5:NOTE STICKER
8:DELIVERY STICKER
(2 PCS)
4: 4
4: 3
4: 2
4: 1
7:UB STICKER
UB2UB1
CAMA
RNAC
Radio Network Controller
Multimedia Gateway
DN0639624 43
Equipment Lists for RNC450 Cabinet stickers
Id:0900d8058083603aConfidential
Figure 14 Stickers already attached on delivery
Guidelines for product collection and safe disposal of the equipment are indicated with a sticker placed on the equipment, shown in the figure below.
ATTENTION!Observeprecautionsfor handlingelectrostaticsensitivedevices UL
THE EDGES OF
THE CABINET
MAY BE SHARP
WARNING
UL
38
EARTHBONDING
POINT
DN03462321
EQUIPPINGSETSUSED INTHISCABINET
B Cabinet typeA
B Upgrade setA
B Upgrade setA
B Upgrade setA
B Upgrade setA
B Location setA
B Alternative setA
B Alternative setA
B Upgrade setA
B Alternative setA
LOT ID LABEL
(2PCS)(2PCS)
(2PCS)
44 DN0639624
Equipment Lists for RNC450
Id:0900d8058083603aConfidential
Cabinet stickers
Figure 15 Product collection and disposal within the European Union
g Stickers attached on delivery include: ESD caution sticker, LOT ID label, Warning sticker about sharp edges, Earth Bonding Point sticker, WEEE sticker, and Equipping sticker (the latter is located at the top of the cabinet).
Product collection and disposal within the European Union
Do not dispose of theproduct as unsortedmunicipal waste. Thecrossed-out wheeledbin means that at theend of the product'slife it must be takento separate collection.
Note: this is applicable onlywithin the European Union(see WEEE Directive 2002/96/EC)