Nokia Siemens Networks WCDMA RNC Rel. RN6.0, Site Documentation, Issue 01 Equipment Lists for RNC450 DN0639624 Issue 03 Approval Date 2011-01-06 Confidential
Transcript
Page 1: Equip List Rnc450

Nokia Siemens Networks WCDMA RNC Rel. RN6.0, Site Documentation, Issue 01

Equipment Lists for RNC450

DN0639624

Issue 03Approval Date 2011-01-06

Confidential

Page 2: Equip List Rnc450

2 DN0639624Issue 03

Equipment Lists for RNC450

Id:0900d80580819cdbConfidential

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2011. All rights reserved

f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.

Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.

The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.

The same text in German:

f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.

Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.

Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-satzes.

Page 3: Equip List Rnc450

DN0639624 3

Equipment Lists for RNC450

Id:0900d80580819cdbConfidential

Table of contentsThis document has 44 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1 About Equipment lists for RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.1 Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.2 Notations used in equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2 RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1 RNAC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1.1 Subracks, fan trays, and cable supporting shelves to the front . . . . . . . 112.1.2 Subracks for back interfaces, panels, and cable supporting shelves to the

rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.1.3 Back interface units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.1.4 Equipment kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.2 RNAC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 162.3 RNAC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 212.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

3 RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233.1 RNBC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233.1.1 Subracks, fan trays, and cable supporting shelves to the front . . . . . . . 233.1.2 Subracks for back interfaces and cable supporting shelves to the rear. 233.1.3 Equipment kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243.1.4 Grounding set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243.2 RNBC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 263.3 RNBC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 313.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

4 NIS1P, NIS1 and NIP1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 324.1 NIP1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324.2 NIS1P and NIS1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324.2.1 Equipping NIS1P and NIS1 units to RNC450 step 1 . . . . . . . . . . . . . . . 334.2.2 Equipping NIS1P and NIS1 units to RNC450 step 2 . . . . . . . . . . . . . . . 354.2.3 Equipping NIS1P and NIS1 units to RNC450 step 3 . . . . . . . . . . . . . . . 37

5 Cabinet stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Page 4: Equip List Rnc450

4 DN0639624

Equipment Lists for RNC450

Id:0900d80580819cdbConfidential

List of figuresFigure 1 Notations used in the equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Figure 2 Positions of CPSY-A, CPSY-B, and CPAL-A panels . . . . . . . . . . . . . . . 13Figure 3 BIE1T and BIE1C equipping principle with SRBI-C . . . . . . . . . . . . . . . . 14Figure 4 Functional units of the RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 5 Grounding between RNAC and RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . 25Figure 6 Functional units of the RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Figure 7 NIS1P, NIS1 and NIP1 equipping positions inRNC450 step 1 . . . . . . . . 33Figure 8 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2 . . . . . . . 35Figure 9 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3 . . . . . . . 37Figure 10 NIS1 1 equipping restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Figure 11 NIS1 3 equipping restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 12 IPA2800 cabinet; note that front and back sides are identical . . . . . . . . 41Figure 13 IPA2800 cabinet stickers; the stickers in the figure are attached to all cab-

inets except Network Element Name stickers and Marking strips . . . . . 42Figure 14 Stickers already attached on delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Figure 15 Product collection and disposal within the European Union . . . . . . . . . . 44

Page 5: Equip List Rnc450

DN0639624 5

Equipment Lists for RNC450

Id:0900d80580819cdbConfidential

List of tablesTable 1 RNAC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Table 2 Subracks and fan trays to the front for the RNAC . . . . . . . . . . . . . . . . . 11Table 3 Subracks for back interfaces, panels, and cable supporting shelves for the

RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Table 4 Back interface units of the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Table 5 Equipment kit EQIK216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Table 6 Functional units, plug-in units, and memory modules of the RNAC . . . 17Table 7 Marking strips for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 8 Stickers for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 9 RNBC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Table 10 Subracks and fan trays to the front for the RNBC . . . . . . . . . . . . . . . . . 23Table 11 Subracks for back interfaces and cable supporting shelves for RNBC . 23Table 12 Equipment kit EQIS216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Table 13 Grounding sets for RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Table 14 Functional units and plug-in units of the RNBC . . . . . . . . . . . . . . . . . . 27Table 15 Marking strips for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 16 Stickers for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 17 STM-1/OC-3 ATM interfaces in RNC450 . . . . . . . . . . . . . . . . . . . . . . . 32Table 18 Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Table 19 Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Table 20 Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Page 6: Equip List Rnc450

6 DN0639624

Equipment Lists for RNC450

Id:0900d80580819cdbConfidential

Page 7: Equip List Rnc450

DN0639624 7

Equipment Lists for RNC450 Summary of changes

Id:0900d8058081d12bConfidential

Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.

Changes between issue 2-2 and 03RRMU and NEMU related information is deleted. CCP1D-A, HDS-C and ESA40 related information is added.

Equipping rules are updated. HDS-C is one slot plug-in unit and HDS-B is two slots pulgin unit, so F15 is only occupied when use HDS-B.

Changes between issue2-1 and 2-2Section NIS1P, NIS1 and NIP1 equipping rules updated: equipping rules and restric-tions are described for each RNC450 capacity step separately.

Changes between issue 2-0 and 2-1A new CPU variant CCP18-C is taken into use. CCP18-A is still used with OMU, because the USB port is needed for backup purposes.

Page 8: Equip List Rnc450

8 DN0639624

Equipment Lists for RNC450

Id:0900d80580836038Confidential

About Equipment lists for RNC450

1 About Equipment lists for RNC450Equipment lists for RNC450 provides a list of cabinet mechanics, subracks, and plug-in units installed in the RNAC and RNBC cabinets for RNC450. Sections RNAC cabinet and RNBC cabinet include the physical positions of the hardware items inside the cab-inets.

RNC450 features three capacity steps:

• RNC450 capacity step 1 = RNC450/150 (RNAC) • RNC450 capacity step 2 = RNC450/300 (RNBC Subrack 1–2) • RNC450 capacity step 3 = RNC450/450 (RNBC Subrack 3–4)

1.1 Related documentsCable ListsDetailed information on cabling and individual cables can be found in Cable Lists for RNC450.

Engineering DescriptionBasic information on, for example, RNC installation planning can be found in Engineer-ing for Radio Network Controller (RNC).

Installation ManualDetailed information on the installation of RNC hardware, see Installing the MGW and RNC.

Cabinet Interfaces and CablingDetailed information on cabinet interfaces and cabling can be found in Cabinet Inter-faces and External Cables of MGW and RNC.

1.2 Notations used in equipment listsThe equipment lists contain the columns shown in the figure below, with their contents described in the list which follows.

Page 9: Equip List Rnc450

DN0639624 9

Equipment Lists for RNC450 About Equipment lists for RNC450

Id:0900d80580836038Confidential

Figure 1 Notations used in the equipment lists

The positions are presented in the form of a table. The figure shows only one table type, but tables can have the following columns:

• Side indicates the side on which the unit in question is equipped. (F = Front, B = Back)

• Mounting hole no. indicates the number of the mounting hole used for the installation of the particular unit.

• Subrack indicates the subrack position of a specific unit. • Position shows the coordinates inside the rack and the number of the slot in the car-

tridge. • ID (Identification) shows the identification code of the cabinet, cartridge, plug-in unit,

or accessory. • Name shows the abbreviated name of the hardware product for the identification

code in the previous column.

IPA2800 RNC / MGW cabinet,front view

DN05158674

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

38

SUBRACK 3front view

Plug-in unit position number

1

SUBRACK 1

SUBRACK 2

SUBRACK 3

SUBRACK 4

Position ID Name FU Notes

F01 C105546 CDSP-C DMCU 4

F02 C105546 CDSP-C DMCU 5

F03 C109093 ICSU 4

1

Subrack 3

CCP18-A Mounted2GB memoryincluded

Page 10: Equip List Rnc450

10 DN0639624

Equipment Lists for RNC450

Id:0900d80580836038Confidential

About Equipment lists for RNC450

• PIU indicates the name of the plug-in unit in question. • FU (Functional Unit) shows the name and index number of the functional unit

equipped into the cartridge in this particular position. • Use shows the name and number of the functional unit, which contains the plug-in

units listed below and equipped in this cartridge position. • Notes column includes additional information.

When two or more different hardware products can be equipped in the same position, the identification code and name of each type is given.

Page 11: Equip List Rnc450

DN0639624 11

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058081d12dConfidential

2 RNAC cabinetThis section lists all the equipment mechanics for the RNAC cabinet.

2.1 RNAC cabinet mechanics

2.1.1 Subracks, fan trays, and cable supporting shelves to the front

Equipping Side Mounting hole no.

ID Name Use

C109740 EC216 Cabinet

F C109742 DR216 Door right

F C109743 DL216 Door left

B C109742 DR216 Door right

B C109743 DL216 Door left

F C110052 CPD120-A Power distribution and fuse unit

F C110052 CPD120-A Power distribution and fuse unit

F C110505 CAIND-A Cabinet Alarm indi-cator

C110076 SCP216 Side cover plate

C110076 SCP216 Side cover plate

Table 1 RNAC cabinet mechanics

Side Mounting hole no.

ID Name Use

F 53 C109979 SRA3 Subrack

F 49 C109730 FTRA-B Fan tray

F 37 C109979 SRA3 Subrack

F 33 C109730 FTRA-B Fan tray

F 21 C109979 SRA3 Subrack

F 17 C109730 FTRA-B Fan tray

F 5 C109979 SRA3 Subrack

F 1 C109730 FTRA-B Fan tray

Table 2 Subracks and fan trays to the front for the RNAC

Page 12: Equip List Rnc450

12 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12dConfidential

RNAC cabinet

2.1.2 Subracks for back interfaces, panels, and cable supporting shelves to the rear

Side Mounting hole no./ Position

ID Name Use Notes

B 53 C110568 SRBI-C Subrack for back inter-faces

B 50 C110730 CS216-A Cable supporting shelf

B 50.01 C110551 CPSY-A Connector panel for syn-chronisation

B 50.10 C110747 CPSY-B Connector panel for syn-chronisation

B 37 C110568 SRBI-C Subrack for back inter-faces

B 35 C110730 CS216-A Cable supporting shelf

B 35.01 C110487 CPAL-A Connector panel for alarms

B 21 C105864 CS186-B Cable supporting shelf

B 21 C110568 SRBI-C Subrack for back inter-faces

B 5 C110568 SRBI-C Subrack for back inter-faces

B 1 C105864 CS186-B Cable supporting shelf

Table 3 Subracks for back interfaces, panels, and cable supporting shelves for the RNAC

Page 13: Equip List Rnc450

DN0639624 13

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058081d12dConfidential

Figure 2 Positions of CPSY-A, CPSY-B, and CPAL-A panels

2.1.3 Back interface unitsBIE1T and BIE1C are optional back interface units for RNAC. They are used with NIP1 0.

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

CPSY-A

CPAL-A

CPSY-B

DN05160803

Page 14: Equip List Rnc450

14 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12dConfidential

RNAC cabinet

Figure 3 BIE1T and BIE1C equipping principle with SRBI-C

Subrack Position ID PIU Name

3.0B 15 C103060 BIE1T Back interface unit for E1, T1 and JT1

C103030 BIE1C Back Interface unit for E1

Table 4 Back interface units of the RNAC

SMB connectorSingle or multicoaxial cable

RJ-45 connectorMulticable

BIE1T

SRBI-C

NIP1

DN70200648BIE1C

SRBI-C

NIP1

Page 15: Equip List Rnc450

DN0639624 15

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058081d12dConfidential

2.1.4 Equipment kits

The EQIK216 equipment kit contains the following items:

• washers • static control wrist strap • screws • pink minigrip bags • locking pegs • cable ties

ID Name Use

C110720 EQIK216 Installation set for RNAC

Table 5 Equipment kit EQIK216

Page 16: Equip List Rnc450

16 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12dConfidential

RNAC cabinet

2.2 RNAC functional units and plug-in units

Figure 4 Functional units of the RNAC cabinet

Equipping rulesCapacity step 1 includes all RNAC subracks. All units except the interface units (NIS1P, NIS1 and NIP1) are equipped in index order, starting from the lowest index. For equip-ping rules of the interface units, see section NIS1P, NIS1 and NIP1 equipping rules.

1. Install all units except NIS1P, NIS1 and NIP1 0 in index order, starting from the unit indexed as 0.

Page 17: Equip List Rnc450

DN0639624 17

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058081d12dConfidential

2. Install optional NIP1 0, if used.3. Install 2N redundant NIS1P pairs and non-redundant NIS1 units. See the equipping

rules and restrictions in section NIS1P, NIS1 and NIP1 equipping rules.4. Install cover plates for the slots that remain empty.5. If CCP1D-A is used for OMU or RSMU also redundant unit must be CCP1D-A. If

CCP1D-A is used for OMU the replacement of HDS-B to HDS-C is mandatory and standalone OMS should be used instead of integrated OMS.

The following units are ordered separately:

• Optional second ESA40-A/ESA24 • Optional NIP1 0 • NIS1P/NIS1 2–3 • NIS1P 10-11

Position ID Name FU Notes

Subrack 1

F01

F02

C110899

C100580

SF10E

/SF10

SFU 0

F03 C110830 CDSP-DH DMCU 0

F04 C110830 CDSP-DH DMCU 1

F05 C111417

C108427

ESA40-A

ESA24

SWU 0

F06 C11054 MCP18-B OMS Mounted 4GB memory included

F07 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 22 1)

F08 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

RSMU 0 1)

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 0

F10 C109472 PD30 – Subrack power

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 1

F12 C109047 AL2S-D A2SU 0

F13 C109047 AL2S-D A2SU 1

Table 6 Functional units, plug-in units, and memory modules of the RNAC

Page 18: Equip List Rnc450

18 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12dConfidential

RNAC cabinet

F14

F15

C111977

C109941

HDS-C

HDS-B

WDU 0

HDD 0

HDS-C is used with HDS14-A(P01113). HDS-B is used with WDW147(P01118) or WDW 73(P01098).

HDS-C is one slot plug-in unit and HDS-B is two slots pulg-in unit, so F15 is only occupied when use HDS-B.

A = OMU

B = OMS (closest to front panel)

F16 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

OMU 0 1)

F17 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 0 1)

F18 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 1 1)

F19 C08986 TSS3 TBU 0

F38 C71700 TBUF TBU 1

Subrack 2

F01

F02

C110899

C100580

SF10E

/SF10

SFU 1

F03 C110830 CDSP-DH DMCU 2

F04 C110830 CDSP-DH DMCU 3

F05 C111417

C108427

ESA40-A

ESA24

SWU 1 Optional

F06 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 0 1)

F07 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 23 1)

F08 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

RSMU 1 1)

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 2

F10 C109472 PD30 – Subrack power

Position ID Name FU Notes

Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)

Page 19: Equip List Rnc450

DN0639624 19

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058081d12dConfidential

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 3

F12 C109047 AL2S-D A2SU 2

F13

F14

C111977

C109941

HDS-C

HDS-B

WDU 1

HDD 1

HDS-C is used with HDS14-A(P01113). HDS-B is used with WDW147(P01118) or WDW 73(P01098).

HDS-C is one slot plug-in unit and HDS-B is two slots pulg-in unit, so F13 is only occupied when use HDS-B.

A = OMU

B = OMS (closest to front panel)

F15 C100880 EHAT EHU

F16 C109093 CCP18-A OMU 1 1)

F17 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 2 1)

F18 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 3 1)

F19 C71700 TBUF TBU 0

F38 C08986 TSS3 TBU 1

Subrack 3

F01 C110830 CDSP-DH DMCU 4

F02 C110830 CDSP-DH DMCU 5

F03 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 4 1)

F04 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 5 1)

F05 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 6 1)

F06 C110830 CDSP-DH DMCU 6

F07 C110830 CDSP-DH DMCU 7

F08 C110830 CDSP-DH DMCU 8

Position ID Name FU Notes

Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)

Page 20: Equip List Rnc450

20 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12dConfidential

RNAC cabinet

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 4

F10 C109472 PD30 – Subrack power

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 5

F12 C109047 AL2S-D A2SU 3

F13 C110830 CDSP-DH DMCU 9

F14 C110830 CDSP-DH DMCU 10

F15 C100790

C100610

NI16P1A

NI4S1-B

NIP1 0

NIS1P 10

Ordered separately

NIP1 0 equipping requires cabling changes and the adding of BIE1T/C back interface panel

NIS1P 10 can be equipped either in RNAC or RNBC.

If NIS1 3 is configured, NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured.

F16 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 1 1)

F17 C100610 NI4S1-B NIS1P 0

NIS1 0

Included in capacity step RNC450/150

F18 C100610 NI4S1-B NIS1P 2

NIS1 2

Ordered separately

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Subrack 4

F01 C110830 CDSP-DH DMCU 11

F02 C110830 CDSP-DH DMCU 12

F03 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 7 1)

F04 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 8 1)

F05 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 9 1)

Position ID Name FU Notes

Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)

Page 21: Equip List Rnc450

DN0639624 21

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058081d12dConfidential

2.3 RNAC cabinet stickers and marking stripsSee Figure IPA2800 stickers in section Cabinet stickers for the locations of the marking strips and stickers.

F06 C110830 CDSP-DH DMCU 13

F07 C110830 CDSP-DH DMCU 14

F08 C110830 CDSP-DH DMCU 15

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 6

F10 C109472 PD30 – Subrack power

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 7

F12 C109047 AL2S-D A2SU 4

F13 C110830 CDSP-DH DMCU 16

F14 C110830 CDSP-DH DMCU 17

F15 C100610 NI4S1-B NIS1P 11 Ordered separately

NIS1P 11 can be equipped either in RNAC or RNBC.

If NIS1 3 is configured, NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured.

F16 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 2 1)

F17 C100610 NI4S1-B NIS1P 1

NIS1 1

Included in capacity step RNC450/150

If NIS1 1 is configured, NIS1P/NIS1 8 and NIS1P 9 in RNBC cannot be con-figured.

F18 C100610 NI4S1-B NIS1P 3

NIS1 3

Ordered separately

If NIS1 3 is configured, NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured.

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

1) CCP1D-A is mounted 4GB memory. CCP18-A and CCP18-C is mounted 2GB?

Position ID Name FU Notes

Table 6 Functional units, plug-in units, and memory modules of the RNAC (Cont.)

Page 22: Equip List Rnc450

22 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12dConfidential

RNAC cabinet

2.3.1 Marking strips

2.3.2 Stickers

Position Name Use

F 1 RNAC F1 IPA2800 Marking Strip for subrack 1

F 2 RNAC F2 IPA2800 Marking Strip for subrack 2

F 3 RNAC F3 IPA2800 Marking Strip for subrack 3

F 4 RNAC F4 IPA2800 Marking Strip for subrack 4

Table 7 Marking strips for the RNAC

Position Code Name Use Notes

F Name sticker RNAC (window)

Network Element Sticker

B Name sticker RNAC Network Element Sticker

F Identifier sticker sheet Subrack position number sticker

F ESD sticker Each subrack 4 pcs

T Note sticker

T UB 1 sticker Power sticker

T UB 2 sticker Power sticker

HDD (OMS) sticker Identification sticker for OMS hard disk on HDS-C

2 pcs

WDU (OMU) sticker Identification sticker for OMU hard disk on HDS-C

2 pcs

Table 8 Stickers for the RNAC

Page 23: Equip List Rnc450

DN0639624 23

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058081d12fConfidential

3 RNBC cabinetThis section lists all the equipment mechanics for the RNBC cabinet.

3.1 RNBC cabinet mechanics

3.1.1 Subracks, fan trays, and cable supporting shelves to the front

3.1.2 Subracks for back interfaces and cable supporting shelves to the rear

Equipping Side Mounting hole no.

ID Name Use

C109740 EC216 Cabinet

F C109742 DR216 Door right

F C109743 DL216 Door left

B C109742 DR216 Door right

B C109743 DL216 Door left

F C110052 CPD120-A Power distribution and fuse unit

F C110052 CPD120-A Power distribution and fuse unit

Table 9 RNBC cabinet mechanics

Equipping Side Mounting hole no.

ID Name Use

F 53 C109979 SRA3 Subrack

F 49 C109730 FTRA-B Fan tray

F 37 C109979 SRA3 Subrack

F 33 C109730 FTRA-B Fan tray

F 21 C109979 SRA3 Subrack

F 17 C109730 FTRA-B Fan tray

F 5 C109979 SRA3 Subrack

F 1 C109730 FTRA-B Fan tray

Table 10 Subracks and fan trays to the front for the RNBC

Side Mounting hole no.

ID Name Use

B 53 C110568 SRBI-C Subrack for back interfaces

B 50 C105864 CS186-B Cable supporting shelf

Table 11 Subracks for back interfaces and cable supporting shelves for RNBC

Page 24: Equip List Rnc450

24 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12fConfidential

RNBC cabinet

3.1.3 Equipment kits

The EQIS216 equipment kit contains the following items:

• washers • static control wrist strap • screws • pink minigrip bags • locking pegs • cable ties

3.1.4 Grounding setThe grounding cables between RNAC and RNBC cabinets needs to be installed at the site.

The grounding set contains:

• 4 pcs grounding cables • washers • screws

B 37 C110568 SRBI-C Subrack for back interfaces

B 35 C105864 CS186-B Cable supporting shelf

B 21 C110568 SRBI-C Subrack for back interfaces

B 21 C105864 CS186-B Cable supporting shelf

B 5 C110568 SRBI-C Subrack for back interfaces

B 1 C105864 CS186-B Cable supporting shelf

Side Mounting hole no.

ID Name Use

Table 11 Subracks for back interfaces and cable supporting shelves for RNBC (Cont.)

ID Name Use

C110721 EQIS216 Installation set for RNBC

Table 12 Equipment kit EQIS216

ID Name Use Notes

C109878 Grounding set Grounding RNAC to RNBC EC216 to EC216

Table 13 Grounding sets for RNBC

Page 25: Equip List Rnc450

DN0639624 25

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058081d12fConfidential

Figure 5 Grounding between RNAC and RNBCREAR SIDE OF CABINET DN0644085

EC216

EC216

Page 26: Equip List Rnc450

26 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12fConfidential

RNBC cabinet

3.2 RNBC functional units and plug-in units

Figure 6 Functional units of the RNBC cabinet

Equipping rulesSubracks 1–2 form capacity step RNC450/300, subracks 3–4 is capacity step RNC450/450. NIS1P/NIS1 units are ordered separately as needed.

All units except the interface units (NIS1P, NIS1) are equipped in index order, starting from the lowest index. For equipping rules of the interface units, see section NIS1P, NIS1 and NIP1 equipping rules.

1. Install all units except NIS1P and NIS1 in index order, starting from the lowest index.2. Install 2N redundant NIS1P pairs and non-redundant NIS1 units. See the equipping

rules and restrictions in section NIS1P, NIS1 and NIP1 equipping rules.

RNBC

DN0624954 FRONT VIEW

ICS

U16

ICS

U17

ICS

U18

DM

CU

31

DM

CU

32

DM

CU

33

MX

U12

PD

30

MX

U13

A2S

U7

DM

CU

34

TB

U1

TB

U0

DM

CU

30

- DM

CU

36

DM

CU

35

NIS

1P

/N

IS1

8

NIS

1P

/N

IS1

10

GT

PU

6

ICS

U13

ICS

U14

ICS

U1

5

- DM

CU

26

DM

CU

27

MX

U10

PD

30

MX

U11

A2S

U6

DM

CU

28

TB

U1

TB

U0

DM

CU

25

- GT

PU

4

DM

CU

29

NIS

1P

5

NIS

1P

7

GT

PU

5

ICS

U10

ICS

U11

ICS

U12

DM

CU

19

DM

CU

20

DM

CU

21

MX

U8

PD

30

MX

U9

A2

SU

5

DM

CU

22

TB

U1

TB

U0

DM

CU

18

- DM

CU

24

DM

CU

23

NIS

1P

/N

IS1

4

NIS

1P

/N

IS1

6

GT

PU

3

ICS

U19

ICS

U20

ICS

U21

DM

CU

38

DM

CU

39

DM

CU

40

MX

U14

PD

30

MX

U1

5

A2S

U8

DM

CU

41

TB

U1

TB

U0

DM

CU

37

- DM

CU

43

DM

CU

42

NIS

1P

9

NIS

1P

11

GT

PU

7

Page 27: Equip List Rnc450

DN0639624 27

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058081d12fConfidential

3. Install cover plates for the slots that remain empty.

Position ID Name FU Notes

Subrack 1

F01 — — —

F02 C110830 CDSP-DH DMCU 18

F03 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 10 1)

F04 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 11 1)

F05 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 12 1)

F06 C110830 CDSP-DH DMCU 19

F07 C110830 CDSP-DH DMCU 20

F08 C110830 CDSP-DH DMCU 21

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 8

F10 C109472 PD30 – Subrack power

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 9

F12 C109047 AL2S-D A2SU 5

F13 C110830 CDSP-DH DMCU 22

F14 C110830 CDSP-DH DMCU 23

F15 C110830 CDSP-DH DMCU 24

F16 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 3 1)

F17 C100610 NI4S1-B NIS1P 4

NIS1 4

Ordered separately

F18 C100610 NI4S1-B NIS1P 6

NIS1 6

Ordered separately

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Subrack 2

Table 14 Functional units and plug-in units of the RNBC

Page 28: Equip List Rnc450

28 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12fConfidential

RNBC cabinet

F01 — — —

F02 C110830 CDSP-DH DMCU 25

F03 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 13 1)

F04 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 14 1)

F05 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 15 1)

F06 — — —

F07 C110830 CDSP-DH DMCU 26

F08 C110830 CDSP-DH DMCU 27

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 10

F10 C109472 PD30 – Subrack power

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 11

F12 C109047 AL2S-D A2SU 6

F13 C110830 CDSP-DH DMCU 28

F14 C110830 CDSP-DH DMCU 29

F15 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 4 1)

F16 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 5 1)

F17 C100610 NI4S1-B NIS1P 5 Ordered separately

F18 C100610 NI4S1-B NIS1P 7 Ordered separately

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Subrack 3

F01 — — —

F02 C110830 CDSP-DH DMCU 30

Position ID Name FU Notes

Table 14 Functional units and plug-in units of the RNBC (Cont.)

Page 29: Equip List Rnc450

DN0639624 29

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058081d12fConfidential

F03 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 16 1)

F04 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 17 1)

F05 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 18 1)

F06 C110830 CDSP-DH DMCU 31

F07 C110830 CDSP-DH DMCU 32

F08 C110830 CDSP-DH DMCU 33

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 12

F10 C109472 PD30 – Subrack power

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 13

F12 C109047 AL2S-D A2SU 7

F13 C110830 CDSP-DH DMCU 34

F14 C110830 CDSP-DH DMCU 35

F15 C110830 CDSP-DH DMCU 36

F16 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 6 1)

F17 C100610 NI4S1-B NIS1P 8

NIS1 8

Ordered separately

When NIS1 1 is configured, the NIS1P/NIS1 8 and NIS1P 9 in RNBC cannot be configured.

F18 C100610 NI4S1-B NIS1P 10

NIS1 10

Ordered separately

NIS1P 10 and NIS1P 11 can be equipped either in RNAC or RNBC. If they are configured in RNAC, cabling changes are needed.

When NIS1 3 is configured, the NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be con-figured.

F19 C71700 TBUF TBU 0

Position ID Name FU Notes

Table 14 Functional units and plug-in units of the RNBC (Cont.)

Page 30: Equip List Rnc450

30 DN0639624

Equipment Lists for RNC450

Id:0900d8058081d12fConfidential

RNBC cabinet

F38 C71700 TBUF TBU 1

Subrack 4

F01 — — —

F02 C110830 CDSP-DH DMCU 37

F03 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 19 1)

F04 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 20 1)

F05 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

ICSU 21 1)

F06 C110830 CDSP-DH DMCU 38

F07 C110830 CDSP-DH DMCU 39

F08 C110830 CDSP-DH DMCU 40

F09 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 14

F10 C109472 PD30 – Subrack power

F11 C109700

C105866

C100590

MX622-D

MX622-C

MX622-B

MXU 15

F12 C109047 AL2S-D A2SU 8

F13 C110830 CDSP-DH DMCU 41

F14 C110830 CDSP-DH DMCU 42

F15 C110830 CDSP-DH DMCU 43

F16 C111943

C111034

C109093

CCP1D-A

CCP18-C

CCP18-A

GTPU 7 1)

F17 C100610 NI4S1-B NIS1P 9 Ordered separately

When NIS1 1 is configured, the NIS1P/NIS1 8 and NIS1P 9 in RNBC cannot be configured.

Position ID Name FU Notes

Table 14 Functional units and plug-in units of the RNBC (Cont.)

Page 31: Equip List Rnc450

DN0639624 31

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058081d12fConfidential

3.3 RNBC cabinet stickers and marking stripsSee Figure IPA2800 stickers in Section Cabinet stickers for the locations of the marking strips and stickers.

3.3.1 Marking strips

3.3.2 Stickers

F18 C100610 NI4S1-B NIS1P 11 Ordered separately

NIS1P 10 and NIS1P 11 can be equipped either in RNAC or RNBC. If they are configured in RNAC, cabling changes are needed.

When NIS1 3 is configured, the NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be con-figured.

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

1) CCP1D-A is mounted 4GB memory. CCP18-A and CCP18-C is mounted 2GB?

Position ID Name FU Notes

Table 14 Functional units and plug-in units of the RNBC (Cont.)

Position Name Use

F 1 RNBC F1 IPA2800 Marking Strip for subrack 1

F 2 RNBC F2 IPA2800 Marking Strip for subrack 2

F 3 RNBC F3 IPA2800 Marking Strip for subrack 3

F 4 RNBC F4 IPA2800 Marking Strip for subrack 4

Table 15 Marking strips for the RNBC

Position Name Use Notes

F Name sticker RNBC (window)

Network Element Sticker

B Name sticker RNBC Network Element Sticker

F Identifier sticker sheet

Subrack position number sticker

F ESD sticker Each subrack 4 pcs

T Note sticker

T UB 1 sticker Power sticker

T UB 2 sticker Power sticker

Table 16 Stickers for the RNBC

Page 32: Equip List Rnc450

32 DN0639624

Equipment Lists for RNC450

Id:0900d8058082a3cbConfidential

NIS1P, NIS1 and NIP1 equipping rules

4 NIS1P, NIS1 and NIP1 equipping rulesThis section describes the equipping rules for interface units NIS1P, NIS1 and NIP1 in RNC450.

4.1 NIP1 equipping rulesRNC450 features one optional NIP1 0 unit. It can be equipped as an alternative to NIS1P 10 in RNAC subrack 3 slot 15.

When NIP1 0 is equipped, cabling changes are needed and the BIE1T/BIE1C back interface needs to equipped at the rear of the subrack. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 6 Adding optional NIP1 unit to RNC450.

4.2 NIS1P and NIS1 equipping rulesThe Network Interface Unit STM-1 (NI4S1-B) provides the RNC high bandwidth STM-1/OC-3 ATM interfaces. The unit might be configured either with 2N equipment protec-tion or without 2N equipment protection. When configured with 2N equipment protection the functional unit name is NIS1P. When configured without 2N equipment protection the functional unit name is NIS1.

Non-redundant NIS1 and 2N redundant NIS1P units can be mixed in the same network element. The number of units in mixed configuration is limited by the number of SFU ports available for the STM-1 interface units.

Number and type of STM-1/OC-3 interfaces and units in RNC450Table 11 STM-1/OC-3 ATM interfaces in RNC450 displays the type, and the number of interfaces supported by various RNC450 configurations.

Configuration Max number of unprotected units

Max number of 2N protected units

Number of unpro-tected interfaces (NIS1)

Number of pro-tected interfaces (NIS1P)

RNC450 step 1 4 4 or 61 (2 or 3 pairs) 16 8+8 or 12+12 1

RNC450 step 2 6 6 (3 pairs) 24 16+16 or 20+202

RNC450 step 3 12 12 (6 pairs) 24 24+24

1 6 units and 12+12 interfaces applies only if NIP1 is not used.2 10 units and 20+20 interfaces applies only if NIP1 is not used.

Table 17 STM-1/OC-3 ATM interfaces in RNC450

Page 33: Equip List Rnc450

DN0639624 33

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058082a3cbConfidential

4.2.1 Equipping NIS1P and NIS1 units to RNC450 step 1Figure 2 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 1 shows the correct locations for NIx1x units.

Figure 7 NIS1P, NIS1 and NIP1 equipping positions inRNC450 step 1

Table 12 Number of units in mixed configurations of 2N redundant and non-redundant units in RNC450 step 1 describes how many units can be configured as 2N redundant when also non-redundant units are used, and vice versa.

DN70392866

RNAC

NIS

1P

0/

NIS

10

NIS

1P

2/N

IS1

2

NIS

1P

1/

NIS

11

NIS

1P

3/

NIS

13

NIS

1P

10

/N

IP1

0N

IS1P

11

Optionalequippingpositions forNIS1P 10-11in RNAC,if NIP1 0 is notequipped

Equippingposition foroptionalNIP1 0

Page 34: Equip List Rnc450

34 DN0639624

Equipment Lists for RNC450

Id:0900d8058082a3cbConfidential

NIS1P, NIS1 and NIP1 equipping rules

The number of units in mixed configuration is limited by the number of SFU ports avail-able for the STM-1 interface units. The equipping restrictions in RNC450 step 1 are:

• When NIS1 3 is configured, the NIS1P 10 and NIS1P 11 cannot be configured. See, figure 6 NIS1 3 equipping restriction.

• NIS1P 10 and NIS1P 11 can be equipped either in RNAC (optional) or RNBC (default). If they are equipped in RNAC, cabling changes are needed. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P and NIS1 units to RNC450

Non-redundant NIS1 units

No. of units

0 1 2 3 4 5 6

No. of inter-faces

0 4 8 12 16 20 24

2N redundant NIS1P units

0 pair 0+0 x x x x x - -

1 pair 4+4 x x x x - - -

2 pair 8+8 x x x - - - -

3 pair 12+12 x - - - - - -

Table 18 Number of units in mixed configurations of 2N redundant and non-redun-dant units in RNC450 step 1

Page 35: Equip List Rnc450

DN0639624 35

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058082a3cbConfidential

4.2.2 Equipping NIS1P and NIS1 units to RNC450 step 2Figure 3 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2 shows the correct locations for NIx1x units.

Figure 8 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2

Table 13 Number of units in mixed configurations of 2N redundant and non-redundant units in RNC450 step 2 describes how many units can be configured as 2N redundant when also non-redundant units are used, and vice versa.

DN70392893

RNAC RNBC

NIS

1P

0/

NIS

10

NIS

1P

2/N

IS1

2

NIS

1P

1/N

IS1

1

NIS

1P

3/

NIS

13

NIS

1P

4/

NIS

14

NIS

1P

6/

NIS

16

NIS

1P

5

NIS

1P

7

NIS

1P

10

/N

IP1

0N

IS1P

11

Optionalequippingpositions forNIS1P 10-11in RNAC,if NIP1 0 is notequipped

NIS1P 5 and 7units are equippedonly when the unitsare configuredwith 2n redundancy

Equippingposition foroptionalNIP1 0

Page 36: Equip List Rnc450

36 DN0639624

Equipment Lists for RNC450

Id:0900d8058082a3cbConfidential

NIS1P, NIS1 and NIP1 equipping rules

The number of units in mixed configuration is limited by the number of SFU ports avail-able for the STM-1 interface units. The equipping restrictions in RNC450 step 2 are:

• When NIS1 3 is configured, the NIS1P 10 and NIS1P 11 cannot be configured. See figure 6 NIS1 3 equipping restriction.

• NIS1P 10 and NIS1P 11 can be equipped either in RNAC (optional) or RNBC (default). If they are configured in RNAC, cabling changes are needed. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P and NIS1 units to RNC450.

Non-redundant NIS1 units

No. of units

0 1 2 3 4 5 6

No. of interfaces

0 4 8 12 16 20 24

2N redundant NIS1P units

0 pair 0+0 x x x x x x x

1 pair 4+4 x x x x x x -

2 pair 8+8 x x x x x - -

3 pair 12+12 x x x - - - -

4 pair 16+16 x - - - - - -

5 pair 20+20 x - - - - - -

Table 19 Number of units in mixed configurations of 2N redundant and non-redun-dant units in RNC450 step 2

Page 37: Equip List Rnc450

DN0639624 37

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058082a3cbConfidential

4.2.3 Equipping NIS1P and NIS1 units to RNC450 step 3Figure 4 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3 shows the correct locations for NIx1x units.

Figure 9 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3

Table 14 Number of units in mixed configurations of 2N redundant and non-redundant units in RNC450 step 3 describes, how many units can be configured as 2N redundant when also non-redundant units are used, and vice versa.

DN70347799

RNAC RNBC

NIS

1P

0/

NIS

10

NIS

1P

2/N

IS1

2

NIS

1P

1/N

IS1

1

NIS

1P

3/

NIS

13

NIS

1P

4/

NIS

14

NIS

1P

6/

NIS

16

NIS

1P

5

NIS

1P

7

NIS

1P

8/N

IS1

8

NIS

1P

10

/N

IS1

10

NIS

1P

9

NIS

1P

11

NIS

1P

10

/N

IP1

0N

IS1P

11

Alternativeequippingpositions forNIS1P 10-11

NIS1P 5, 7, 9 and 11units are equippedonly when the unitsare configuredwith 2n redundancy

Equippingposition foroptionalNIP1 0

Page 38: Equip List Rnc450

38 DN0639624

Equipment Lists for RNC450

Id:0900d8058082a3cbConfidential

NIS1P, NIS1 and NIP1 equipping rules

The number of units in mixed configuration is limited by the number of SFU ports avail-able for the STM-1 interface units. The equipping restrictions in RNC450 step 3 are:

• When NIS1 1 is configured, the NIS1P 8 and NIS1P 9 in RNBC cannot be config-ured. See figure 5 NIS1 1 equipping restriction.

• When NIS1 3 is configured, the NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC cannot be configured. See, figure 6 NIS1 3 equipping restriction.

• NIS1P 10 and NIS1P 11 can be equipped either in RNAC or RNBC. If they are con-figured in RNAC, cabling changes are needed. For the RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P and NIS1 units to RNC450.

Non-redundant NIS1 units

No. of units

0 1 2 3 4 5 6

No. of inter-faces

0 4 8 12 16 20 24

2N redundant NIS1P units

0 pair 0+0 x x x x x x x

1 pair 4+4 x x x x x x -

2 pair 8+8 x x x x x - -

3 pair 12+12 x x x x - - -

4 pair 16+16 x x x - - - -

5 pair 20+20 x x - - - - -

6 pair 24+24 x - - - - - -

Table 20 Number of units in mixed configurations of 2N redundant and non-redun-dant units in RNC450 step 3

Page 39: Equip List Rnc450

DN0639624 39

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058082a3cbConfidential

Figure 10 NIS1 1 equipping restrictionDN70347378

RNAC RNBC

NIS

1P

0/

NIS

10

NIS

1P

2/N

IS1

2

NIS

11

NIS

1P

3/

NIS

13

NIS

1P

4/

NIS

14

NIS

1P

6/

NIS

16

NIS

1P

5

NIS

1P

7

NIS

1P

8/N

IS1

8

NIS

1P

10

/N

IS1

10

NIS

1P

9

NIS

1P

11

NIS

1P

10

NIS

1P

11

If NIS1 1 isequipped,NIS1P 8-9cannot beequipped inRNBC

Page 40: Equip List Rnc450

40 DN0639624

Equipment Lists for RNC450

Id:0900d8058082a3cbConfidential

NIS1P, NIS1 and NIP1 equipping rules

Figure 11 NIS1 3 equipping restrictionDN70399108

RNAC RNBC

NIS

1P

0/

NIS

10

NIS

1P

2/N

IS1

2

NIS

1P

1/

NIS

11

NIS

13

NIS

1P

4/

NIS

14

NIS

1P

6/

NIS

16

NIS

1P

5

NIS

1P

7

NIS

1P

8/N

IS1

8

NIS

1P

10

/N

IS1

10

NIS

1P

9

NIS

1P

11

NIS

1P

10

NIS

1P

11

If NIS1 3 isequipped,NIS1P 10-11cannot beequipped inRNAC or RNBC.

Page 41: Equip List Rnc450

DN0639624 41

Equipment Lists for RNC450 Cabinet stickers

Id:0900d8058083603aConfidential

5 Cabinet stickers

Figure 12 IPA2800 cabinet; note that front and back sides are identical

Radio Network Controller

RNAC

IPA2800

DN01173112

Page 42: Equip List Rnc450

42 DN0639624

Equipment Lists for RNC450

Id:0900d8058083603aConfidential

Cabinet stickers

Figure 13 IPA2800 cabinet stickers; the stickers in the figure are attached to all cabinets except Network Element Name stickers and Marking strips

ATTENTION!Observeprecautionsfor handlingelectrostaticsensitivedevices UL

THE EDGES OF

THE CABINET

MAY BE SHARP

WARNING

UL

(2 PCS)

CAMA

FOR DC SUPPLYFUSE VALUESREFER TOUSER MANUAL

NOTE

DN01173093

3:MARKING STRIP SR4

3:MARKING STRIP SR3

3:MARKING STRIP SR2

3:MARKING STRIP SR1

6:ESD STICKER(4 PCS)

SRA1 IDENTIFIER STICKER

2:NAME STICKER RNAC (2pcs)

1:NAME STICKER CAMA (2pcs)

5:NOTE STICKER

8:DELIVERY STICKER

(2 PCS)

4: 4

4: 3

4: 2

4: 1

7:UB STICKER

UB2UB1

CAMA

RNAC

Radio Network Controller

Multimedia Gateway

Page 43: Equip List Rnc450

DN0639624 43

Equipment Lists for RNC450 Cabinet stickers

Id:0900d8058083603aConfidential

Figure 14 Stickers already attached on delivery

Guidelines for product collection and safe disposal of the equipment are indicated with a sticker placed on the equipment, shown in the figure below.

ATTENTION!Observeprecautionsfor handlingelectrostaticsensitivedevices UL

THE EDGES OF

THE CABINET

MAY BE SHARP

WARNING

UL

38

EARTHBONDING

POINT

DN03462321

EQUIPPINGSETSUSED INTHISCABINET

B Cabinet typeA

B Upgrade setA

B Upgrade setA

B Upgrade setA

B Upgrade setA

B Location setA

B Alternative setA

B Alternative setA

B Upgrade setA

B Alternative setA

LOT ID LABEL

(2PCS)(2PCS)

(2PCS)

Page 44: Equip List Rnc450

44 DN0639624

Equipment Lists for RNC450

Id:0900d8058083603aConfidential

Cabinet stickers

Figure 15 Product collection and disposal within the European Union

g Stickers attached on delivery include: ESD caution sticker, LOT ID label, Warning sticker about sharp edges, Earth Bonding Point sticker, WEEE sticker, and Equipping sticker (the latter is located at the top of the cabinet).

Product collection and disposal within the European Union

Do not dispose of theproduct as unsortedmunicipal waste. Thecrossed-out wheeledbin means that at theend of the product'slife it must be takento separate collection.