2017 BUILDING CODE SUMMARY:
APPLICABLE CODESGENERAL ADMINISTRATIVE RULES (GAR) 675 IAC 122014 INDIANA BUILDING CODE (2012 IBC) 675 IAC 13-2.62014 INDIANA MECHANICAL CODE (2012 IMC) 675 IAC 18-1.62014 INDIANA FIRE CODE (2012 IFC) 675 IAC 22-2.52012 INDIANA PLUMBING CODE (2006 IPC) 675 IAC 16-1.42009 INDIANA ELECTRICAL CODE (2008 NFPA 70) 675 IAC17-1.82010 INDIANA ENERGY CONSTRUCTION CODE(ASHRA 90.1, 2007 EDITION, AS AMENDED) 675 IAC 19.3
EXISTING BUILDING AREALOWER LEVEL: 25,772 S.F.FIRST FLOOR: 23,850 S.F.SECOND FLOOR:21,634 S.F.THIRD FLOOR: 16,216 S.F.TOTAL 87,472 S.F.
RENOVATION AREA: 3,389 S.F.
SEISMIC DESIGN CATEGORYCATEGORY C
OCCUPANCY CLASSIFICATIONSOFFICE: GROUP B OCCUPANCY (EDUCATION ABOVE 12TH GRADE)
CONSTRUCTION TYPE:TYPE II-B FULLY SPRINKLED
FIRE RESISTIVE REQUIREMENTSBUILDING ELEMENTS
STRUCTURAL FRAME - 0 HOURFLOOR CONSTRUCTION - 0 HOURROOF CONSTRUCTION - 0 HOURBEARING WALLS - 0 HOURNON-BEARING WALLS - 0 HOUR
1968 BUILDING CODE SUMMARY:
PROJECT DESCRIPTION:NEW CLASSROOM BUILDING TO BE BUILT AT THE UNIVERSITY OF SOUTHERNINDIANA IN EVANSVILLE, INDIANA IS THREE (3) STORIES IN HEIGHT ANDINCLUDES A BASEMENT. THE BUILDING AREA UNDER BASE BID IS 68,100 S.F.A CENTRAL ATRIUM SPACE CONNECTS FLOORS 1 THROUGH 3.
BUILDING HEIGHT:3 STORIES PLUS BASEMENT AND MECHANICAL MEZZANINE.
BUILDING TYPE:IBC TYPE II, 1-HOUR.
OCCUPANCY CLASSIFICATION:GROUP B DIVISION 2.
NUMBER OF OCCUPANTS:1ST FLOOR:2ND FLOOR:3RD FLOOR:BASEMENT:
22990226058
FIRE SUPPRESSION:THE BUILDING IS ENTIRELY PROTECTED THROUGHOUT WITH ASUPERVISED, AUTOMATIC FIRE EXTINGUISHING (SPRINKLER)SYSTEM.
ALLOWABLE FLOOR AREA:BASIC ALLOWABLE = 18,000 S.F. (TABLE 5C). BASIC ALLOWABLE AREAMAY BE MULTIPLIED BY 2 IN ACCORDANCE WITH SECTION 505(b) =36,000 S.F.
ALLOWABLE AREA INCREASES:SEPARATION ON 3 SIDES GREATER THAN 60' ALLOWS 100% INCREASE INALLOWABLE AREA; THEREFORE, 36,000 S.F. + 100% = 72,000 S.F.
FIRE RESISTIVE REQUIREMENTS:NEW CONSTRUCTION IS STRUCTURAL STEEL FRAME WITH 5" POURED-IN-PLACE COMPOSITE CONCRETE FLOOR SLAB. STANDING SEAM METAL ROOFCOVERING IS FIRE-RETARDANT IN ACCORDANCE WITH SECTION 3203(e).
FROM TABLE #17A:
A. STRUCTURAL FRAME 1 HOURB. CEILING / FLOOR ASSEMBLY: 1HOURC. CEILING / ROOF ASSEMBLY: 1 HOURD. SHAFT ENCLOSURES: 1 HOURE. INTERIOR PARTITIONS: 1 HOURF. STAIR ENCLOSURE: 1 HOUR
(SEC. 3309(a))G. CORRIDOR PROTECTION: NOT REQUIRED -
SEC. 3305(g)) EXC. 5
HANDICAP ACCESS:AN ELEVATOR IS PROVIDED FOR ACCESS TO THE FLOOR AREAS. TOILETFACILITIES COMPLY WITH SECTION 511 WITH RESPECT TO CLEAR SPACE,DOOR SWINGS, GRAB BARS, ETC.
EXITS:A. EXITING REQUIREMENTS:
FLOOR1ST2ND3RDBASEMENT
*INCLUDES CASCADE REQUIREMENTS.
B. TRAVEL DISTANCES: 100' FROM TENANT DOORS INACCORDANCE WITH SECTION 1715(d).
# OF EXITS REQ'D2322
EXIT WIDTH REQ'D*20.720.75.21.2
PROJECT LOCATION
USI CAMPUS
WEST LLOYD EXPRESSWAY
UN
IVER
ISTY PA
RKW
AY
PROJECT AREA
REFERENCE SYMBOLS:Room name
101A150 SF
ROOM NUMBER
101 DOOR NUMBER
1
A1.1
1A1.1
1
WALL SECTION/ SECTION DETAIL
A1.1ENLARGED DETAIL
INTERIOR ELEVATION
ELEVATION REFERENCE
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET WHERE DRAWN
A
M
R
ED
N
D
STATE OF
PE60900441
OF I
SS
E
OI
N
R
M
P
E
NLA
I A
E
N A N
GI
ER
AN
W
T
HT EGE
. BEIST
J
R
R CKO
NO.R R
ED
A
N
PE10505044PROF I N
O
ESSI LAN
D I
E
NA
STATE OF
No.
EN
GI
RE
RAT
GAY E
NW S
TSI
.RENE I H
T
DNI
AI AN
No. AR10100128
STATE OF
GER
RTSI EDE
ARCH I T E
CT
JACK
SON R
ICHARDFABER
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Project No. 1701-109Date: March, 2017
03/14/2017 03/14/2017
SHEET INDEXSHEET NO. SHEET NAME
GENERALCov COVERGENERALG1.1 GENERAL INFORMATION & DEMOLITION PLANARCHITECTURALA1.1 FLOOR PLANS, PLAN DETAILSA2.1 DOORS SCHEDULE, INTERIOR ELEVATIONS, DETAILSA2.2 FRAME DETAILSA3.1 FIRST FLOOR FINISH PLAN AND SCHEDULEPLUMBINGP1.1 PLUMBING PLANSMECHANICALM1.1 FIRST FLOOR HVAC PLANM2.1 MECHANICAL DETAILS & SCHEDULESELECTRICALE1.1 ELECTRICAL LEGEND AND BUSSING DIAGRAME2.1 FIRST FLOOR ELECTRICAL DEMOLITION, POWER AND SYSTEMS PLANE3.1 FIRST FLOOR LIGHTING PLAN
1" = 400'-0"USI CAMPUS
1/16" = 1'-0"FIRST FLOOR PROJECT AREA
4'0' 8' 16'
North
North
GENERAL DEMOLITION NOTES:FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY ARCHITECT/ENGINEERIMMEDIATELY OF ANY DISCREPANCIES THAT EXIST.
REMOVE EXISTING CONSTRUCTION AS NOTED AND WHERE SHOWN DASHED.CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION REQUIRED FOR THEINSTALLATION OF NEW WORK AND FOR THE PROTECTION OF ITEMS TO REMAIN.
CONTRACTOR IS RESPONSIBLE FOR ANY DEMOLITION THAT IS NOT SHOWN ONTHE DEMOLITION DRAWINGS BUT IS REQUIRED FOR THE NEW CONSTRUCTION.
REFER TO DEMOLITION REFERENCE NOTES FOR ADDITIONAL WORK ITEMS.
THE OWNER HAS FIRST RIGHT OF REFUSAL OF ALL SALVAGEABLE ITEMSREMOVED DURING DEMOLITION INCLUDING FURNISHINGS AND MILLWORK.
REFER TO MECHANICAL AND ELECTRICAL PLANS FOR REMOVAL AND RELOCATIONAND REROUTING OF THE EXISTING UTILITIES.
DEMOLITION OF EXISTING UTILITIES SHALL BE MADE SO THAT SERVICE TO OTHERAREAS UTILIZED BY THE OWNER ARE NOT INTERRUPTED. PROVIDE TEMPORARYUTILITIES, ISOLATION VALVES, DISCONNECTS, ETC. WHERE REQUIRED DURINGDEMOLITION AND NEW CONSTRUCTION
IF CONTRACTOR BECOMES AWARE OF ANY LOAD BEARING POINTS WITHINDEMOLITION NOT NOTED ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFYARCHITECT/ENGINEER PRIOR TO REMOVING THAT CONSTRUCTION.
PATCH OPENINGS IN WALLS, CEILINGS AND FLOOR RESULTING FROM ALLDEMOLITION WORK. PATCH ALL OPENINGS IN EXISTING CONSTRUCTION AS ARESULT OF ELECTRICAL, PLUMBING AND HVAC MODIFICATIONS. PATCH ALLABOVE WITH MATCHING MATERIALS, CONSTRUCTION AND RATING UNLESS NOTEDOTHERWISE.
PROTECT EXISTING FINISHES AND EQUIPMENT DURING DEMOLITION.
PATCH AND REPAIR ALL EXISTING CONSTRUCTION AND FINISHES DAMAGEDDURING THE DEMOLITION WORK REQUIRED FOR THIS PROJECT. THE REQUIREDREPAIR WORK SHALL MATCH THE NEW CONSTRUCTION AND FINISHES UNLESSNOTED OTHERWISE.
PATCH AND SEAL ALL FLOOR, WALL, AND CEILING PENETRATIONS THAT BECOMEEXPOSED DURING DEMOLITION.
SAW CUT AND PATCH EXISTING FLOOR SLABS AS REQUIRED FOR NEW PIPING.REFER TO PLUMBING DRAWINGS.
REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING PLANS FOR SIZES ANDLOCATIONS OF CUTOUTS.
ALL EXISTING FIRE RATINGS OF THE WALLS, FLOOR AND CEILINGS SHALL BEMAINTAINED.
ALL DEMOLITION ACTIVITY SHALL BE COORDINATED WITH THE UNIVERSITY OFSOUTHERN INDIANA AND THEIR SCHEDULED ACTIVITIES.
OWNER TO REMOVE AND STORE ALL EXISTING FURNITURE.
REMOVE EXISTING CEILINGS WHERE REFLECTED CEILING PLANS INDICATE NEWCEILINGS.
PROVIDE DUST BARRIERS AS REQUIRED TO PREVENT MIGRATION TO AREASOCCUPIED BY OWNER. PROTECT ALL EQUIPMENT TO REMAIN. COORDINATEPROTECTION OF EXISTING EQUIPMENT WITH OWNER.
WHERE NEW FINISHES ON WALLS ARE SCHEDULED, ALL WALLCOVERING SHOULDBE REMOVED PRIOR TO FINISH WORK. PATCH AND REPAIR WALLS TO PROVIDE ALEVEL 4 FINISH PER GYPSUM ASSOCIATION GA 214-10 BEFORE PAINTING.
REFER TO FINISH PLANS AND SCHEDULES. ALL ROOMS INDICATED TO RECEIVENEW FINISHES SHALL HAVE EXISTING FINISHES REMOVED. PREP SUBSTRATESFOR NEW FINISHES INDICATED ON FINISH PLANS AND SCHEDULES.
SALVAGE ANY EXISTING TACK & CHALKBOARD. CONSULT OWNER FOR NEWLOCATION.
REFER TO DOOR SCHEDULE FOR ADDITIONAL REQUIREMENTS.
A.
B.
C.
D.
E.
F.
G.
H.
J.
K.
L.
M.
N.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
DEMOLITION REFERENCE NOTES:REMOVE ENTIRE WALL CONSTRUCTION TO LIMITS SHOWN.
REMOVE EXISTING DOOR, HOLLOW METAL FRAME AND HARDWARE.
REMOVE EXISTING BASE AND WALL CABINETS, COUNTER, CASEWORKAND SHELVING IN THEIR ENTIRETY.
REMOVE EXISTING PLUMBING FIXTURE . REFER TO PLUMBINGDRAWINGS.
REMOVE EXISTING FLOORING, PLYWOOD SUBSTRATE AND METALFRAMING THIS AREA.
RELOCATE EXISTING FIRE EXTINGUISHER AND CABINET AS INDICATEDON FLOOR PLAN
REMOVE AND REINSTALL EXISTING CEILING GRID AS REQUIRED FORINSTALLATION OF NEW CONSTRUCTION.
REMOVE EXISTING DOOR AND HARDWARE, EXISTING FRAME TOREMAIN.
REMOVE VERTICAL GLASS PANEL AND ALUMINUM FRAME AT END OFWALL. CONTRACTOR HAS OPTION TO REUSE IF ABLE TO BE SALVAGEDAND IN GOOD CONDITION. REMOVE CAULK FROM EXTERIOR WINDOW.
REMOVE EXISTING STEPS.
REMOVE EXISTING WINDOW SHADE.
RELOCATE EXISTING REFRIGERATOR.
RELOCATE EXISTING DOOR AND FRAME TO DOOR OPENING 1086-2A.
SALVAGE EXISTING WALL BASE AND REINSTALL AS INDICATED ONFINISH PLAN.
1
2
3
4
5
7
6
8
9
10
11
12
13
14
5678
F
G
H
K
1
11
1
1
1
1 1
2
2
2
2
2
3
3
3
3
1
2
2
4
56
7
9 9
12
10
1111
1111
13
8
8
14
2
14
INTERIOR PARTITION METALSTUD GAUGE SELECTION CHART
16" O.C. STUD SPACING WITH ALLOWABLE DEFLECTION CRITERIA OF L\360
STUDDEPTH
MAXIMUM VERTICALUNBRACED SPAN IN FEET
(1 LAYER GYPSUMBOARD EACH SIDE)
MAXIMUM VERTICALUNBRACED SPAN IN FEET(2 LAYER GYPSUM BOARD
EACH SIDE)
STUDGAUGE
1-5/8" 8'-3" 9'-0" 252-1/2" 10'-9" 11'-9" 252-1/2" 11'-6" 12'-3" 222-1/2" 12'-0" 14'-0" 203-5/8" 14'-0" 14'-9" 253-5/8" 15'-0" 15'-9" 223-5/8" 15'-7" 17'-8" 20
4" 15'-0" 15'-9" 254" 16'-3" 16'-9" 224" 16'-10" 16'-11" 206" 20'-0" 20'-0" 256" 22'-0" 22'-9" 226" 22'-10" 24'-11" 20
MATERIALWALL TYPE LEGEND
G
NOMINAL/ ACTUAL SIZEMETAL STUD
METAL STUD WALLS
3 3-5/8" METAL STUD
SURFACESA 1 LAYER 5/8" TYPE "X" GYP. BD. ON ONE SIDE OF METAL STUD WALL
B 1 LAYER 5/8" TYPE "X" GYP. BD. ON EACH SIDE OF METAL STUD WALL
CONDITIONS1 WALL AND FINISH EXTENDS 6" ABOVE HIGHEST ADJOINING CEILING.
BRACE TOP OF WALL AS REQUIRED.
EXAMPLEG3.B.1 3-5/8" METAL STUD WITH 5/8", TYPE "X", GYP. BD. EACH SIDE. EXTEND WALL
AND BOTH SIDES OF GYPSUM BD. EXTENDS 6" ABOVE HIGHEST ADJOININGCEILING .
GENERAL NOTES1. ALL PARTITIONS EXTEND 6" ABOVE CEILING ABOVE UNLESS NOTED OTHERWISE.
2. STORAGE ROOMS GREATER THAN 100 SF SHALL BE CONSTRUCTED TORESIST THE PASSAGE OF SMOKE.
3. PROVIDE 25 GAUGE METAL STUDS, UNLESS NOTED OTHERWISE ORREQUIRED BY METAL STUD GAUGE SELECTION CHART.
4. PROVIDE (2) 20 GAUGE METAL STUDS AT ALL WINDOW AND DOOR JAMBS.
5. ALL FIRE-RATED PARTITIONS ARE TO BE CONSTRUCTED IN ACCORDANCEWITH APPROPRIATE U.L. ASSEMBLY.
6. REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF SOUNDATTENUATION BLANKETS.
7. PARTITIONS NOT REQUIRED TO EXTEND TO STRUCTURE ABOVE SHALL BEBRACED BY ATTACHING ALTERNATING DIAGONAL STUDS 48" O.C. (MAX.)FROM TOP OF PARTITION TO STRUCTURE ABOVE.
8. FIRE RATED WALLS TO RECEIVE ELECTRICAL OUTLET BOXES SHALLCONFORM TO THE FOLLOWING GUIDELINES. METALLIC OUTLET BOXESSHALL BE UTILIZED IN WALLS AND PARTITIONS WITH A TWO HOUR OR LESSCLASSIFICATION. THE SURFACE AREA OF INDIVIDUAL BOXES SHALL NOTEXCEED 16 SQUARE INCHES. THE AGGREGATE SURFACE AREA OF BOXESSHALL NOT EXCEED 100 SQUARE INCHES IN ANY 100 SQUARE FEET. BOXESLOCATED ON OPPOSITE SIDES OF RATED WALL OR PARTITIONS SHALL BESEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES.
GENERAL FACILITY NOTES:THE CONTRACTOR SHALL ADHERE TO UNIVERSITY OF SOUTHERN INDIANAREQUIREMENTS FOR OUTSIDE CONTRACTORS.
COORDINATE ALL REQUIREMENTS WITH UNIVERSITY OF SOUTHERNINDIANA (FOR CONSTRUCTION) DELIVERY OF MATERIALS TO THE SPACE,CONSTRUCTION TRAFFIC TO AND FROM THE SPACE, KEEPING CORRIDORSFREE FROM DUST AND DEBRIS, CLEANUP AND DISPOSAL OF MATERIALS,ETC.
THE ARCHITECT AND CONTRACTOR SHALL DO A PRE AND POST-CONSTRUCTION WALK THROUGH OF THE EXISTING COMMON AREAS OFTHE PROJECT AREA THAT THE CONTRACTOR WILL USE FOR ACCESS TOTHE PROJECT SITE TO REVIEW EXISTING CONDITIONS AND FINISHES. IF ITIS DETERMINED THAT AREAS WERE DAMAGED BY THE CONSTRUCTIONACTIVITY, THE DAMAGE SHALL BE REPAIRED AT THE COST OF THECONTRACTOR.
EXISTING ITEMS THAT HAVE TO BE RELOCATED SHALL BE RE-INSTALLEDAS IF IT WAS THE ORIGINAL INSTALLATION UNLESS NOTED OTHERWISE.
IF THE CONTRACTOR BELIEVES A DUMPSTER IS REQUIRED FOR THISPROJECT, COORDINATE THE LOCATION WITH THE UNIVERSITY OFSOUTHERN INDIANA.
1.
2.
3.
4.
5.
DNI
AI AN
No. AR10100128
STATE OF
GER
RTSI EDE
ARCH I T E
CT
JACK
SON R
ICHARDFABER
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
G1.1
GENERAL INFORMATION &DEMOLITION PLAN
1/8" = 1'-0"FIRST FLOOR DEMOLITION PLAN
2'0' 4' 8'
North
# Description Date
DN
FLOOR PLAN REFERENCE NOTES:EXISTING MECHANICAL CHASE TO REMAIN.
ALIGN NEW CONSTRUCTION TO EXISTING.
RELOCATED REFRIGERATOR. REFER TO ELECTRICAL AND PLUMBINGDRAWINGS FOR ADDITIONAL INFORMATION.
RELOCATED FIRE EXTINGUISHER AND CABINET TO BE INSTALLED @ 48"TOP.
CLOSET SHELF WITH ROD. REFER TO DETAIL 8, SHEET A2.1.
CORNER GUARD (CG1). SEE FINISH SCHEDULE FOR ADDITIONALINFORMATION. CORNER GURAD TO START AT TOP OF BASE AND EXTENDTO CEILING LINE WITH NO GAP.
END WALL PROTECTION (EWP1). SEE FINISH SCHEDULE FORADDITIONAL INFORMATION. CORNER GURAD TO START AT TOP OF BASEAND EXTEND TO CEILING LINE WITH NO GAP.
PATCH EXISTING WALL TO MATCH ADJACENT. PREPARE SURFACE ASREQUIRED TO RECEIVE NEW FINISH. REFER TO FINISH PLAN FORADDITIONAL INFORMATION.
1
2
3
4
5
7
6
8
5678
F
G
H
K
WAITING1075
OPEN OFFICE1076
CONFERENCE1077
OFFICE1078
OFFICE1079OFFICE
1080OFFICE
1081
OFFICE1082
OFFICE1083
OFFICE1084
OFFICE1085
BREAK1086-1
STORAGE1086-2
VESTIBULE1087
CORR1074
CORR1076-1
CORR1076-2
1086-1A
1086-1B1085A
1086-2B
1077
1086-2A
1076-1
1076
1078
1079
1080
1084
1083
1082
1081
A2.1
3
A2.1
5
A2.1
4
2
2
2
2
2
2
2
15' - 1 3/4" 4 7/8" 19' - 7 7/16" 4 7/8" 14' - 10 5/8"
G3.A.1G3.A.1G3.A.1
G3.A.1
G3.A.1
G3.A.1G3.A.1
10' - 8 15/16" 4 7/8" EQ 4 7/8" EQ 4 7/8" EQ 4 7/8" 20' - 2 1/8"
4 7/
8"3'
- 3"
4 7/
8"
1
14' -
2 7
/8"
7' -
6 1/
4"20
' - 5
"
G3.A.1
G3.A.1
FT4
WORK1076-3
A1.11
Sim
A1.11
Sim
FT6
A1.11
Sim
3
2
2
43' - 5 1/4" 9 3/8"2
2' - 5 1/2"
5
4
6
6
6
6
7
1' -
4 5/
8"1' - 2 5/8"
G3.A.1G3.A.1G3.A.1
6
6
8' -
0"
1075
8
12' -
4 7
/8"
13' -
11
9/16
"
1085B
A2.212 Sim
A2.212
A2.212
Sim
A2.26
A2.212
Sim
A2.23
A2.24
A2.24
A2.25
A2.25
1' - 4"
1' - 4"
5678
F
G
H
K
9' - 0"
9' - 0"9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0" 9' - 0" 9' - 0"
9' - 0"
9' - 0"
8' - 8"
9' - 0"9' - 0"
OFFICE1085
BREAK1086-1
STORAGE1086-2
WAITING1075
OFFICE1084
OFFICE1083
OFFICE1082
OFFICE1081
CONFERENCE1077
OFFICE1078
OFFICE1079
OFFICE1080
CORR1076-2
CORR1076-1
OPEN OFFICE1076
9' - 0"
9' - 0"
9' - 0"
5' -
9"5'
- 2"
EQ9'
- 0"
EQ
2
A1.1
3
A1.1
4
A1.1
WORK1076-3
7' - 0"
4
A1.1
4
A1.1
7' - 0"
9' - 0"
5
A1.1
9' - 0"7' - 0"
8' - 0"
EQ 10' - 0" EQ
C J
C J
C J
C J
C J
C J
1
2
2
2
3
A1.1
Sim
9' - 0"
3
A1.1
Sim
3
9' - 0"
1
1
3
A1.1
Sim
444
5
6
7
1' -
10"
2
A2.22
A2.2
2
A2.2
2
A2.2
1
A2.2
1
A2.2
8
A2.2
8
A2.2
8
A2.2
8
A2.2
8
A2.2
9
A2.2
9
A2.2
9
A2.2
66
6
6
68
9
2' x 4' LIGHT FIXTURE
RECESSED CAN LIGHT FIXTURE
EXIT FIXTURE
WALL MOUNTED LIGHT FIXTURE
2'-0" x 2'-0" SUSPENDEDACOUSTICAL CEILING PANELS
GYPSUM BOARD SOFFIT / CEILING
FINISH HEIGHT OF CEILING / SOFFIT A.F.F.0'-0"
HVAC RETURN AIR
HVAC SUPPLY DIFFUSER
REFLECTED CEILING PLAN SYMBOLS
RECESSED LIGHT FIXTURE
SURFACE MOUNTED LIGHT FIXTURE
"FAST SIZE" CEILING PANEL BY ARMSTRONG
C J CEILING CONTROL JOINT, REFER TODETAIL THIS SHEET
CUT DOWN 2 x 4 CEILING TILE
MUST NOT EXCEED A 1/6 SLOPE (10°).THE PERIMETER. ATTACHMENT WIRE
MUST NOT EXCEED A 1/6 SLOPE (10°).FROM THE WALL. ATTACHMENT WIREPERIMETER WALL A MAXIMUM OF 8"12 GA. HANGER WIRE ANCHORED TO
STRUCTURE ABOVE AND HUNG12 GA. HANGER WIRE ANCHORED TO
VERTICALLY A MAXIMUM OF 8" FROM
SPACER BAR BY USG OR SIMILARAPPROVED SYSTEM TO PREVENTPERIMETER COMPONENTS FROMSPREADING APART.
CONTINUOUS WALL ANGLE ANCHOREDTO PERIMETER WALL @ 24" O.C.
HANGER WIRE PERIMETER SUPPORTSWITH TWO ALTERNATIVES:
2.
1.8" MAX.
3/8" 9/16"
15/16"
MAX.
4"
GYPSUM BOARD CONTROL JOINT
5/8" GYPSUM BOARD
4 7/8"
6"
5/8" GYP. BOARD
METAL EDGE BEAD
3 5/8" METAL STUDS@ 24" O.C.
SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
METAL EDGE BEAD
3 5/8" METAL STUDSBRACING @ 48" O.C.
ELEV., REFER TOCEILING PLAN
SUSPENSION WIRE
SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
9/16" TEE
3 5/8" METAL STUDBRACING @ 32" O.C.
5/8" GYPSUMWALLBOARD
9/16" WALL ANGLE
METAL EDGE BEAD
REFER TO CEILING PLAN
VARIES
ELEV., REFER TOCEILING PLAN
ELEV., REFER TOCEILING PLAN
METAL STUDSCORNER ANGLE
3 5/8" METAL STUDBRACING @ 16" O.C.
VERTICAL WIRE HANGERANCHOR WITH MINIMUMWITHDRAWAL TENSIONCAPACITY OF 100 LBS. ORHIGHER, TYPICAL - PERANCHOR
ROOF OR FLOOR FRAMING
BRACE ANCHOR WITHMINIMUM COMBINEDWITHDRAWAL TENSIONAND SHEAR CAPACITY OF325 LBS. SHORT DURATIONADJUSTMENT MAY BEUSED IF PERMITTED BYPRODUCT'S EVALUATIONREPORT LISTING
4 TIGHT TURNSMINIMUM WITHIN 1 1/2"OF EYE, TYPICAL 12GAUGE WIRE MINIMUM3 TIGHT TURNS MINIMUM
WITHIN 1 1/2" OF EYE,TYPICAL - 12 GAUGEWIRE MINIMUM
90 D
90
45 MAX
45 MAX.
2" MAX
2" MAX
1 1/4" 8'-6"
6'-2"
5'-2"
MAX. LENGTH
1"
3/4"
EMT
PROVIDE VERTICAL STRUT- ELECTRICALMETALLIC TUBING (EMT) SLIPPED OVER VERTICALSUSPENDED WIRE AND CUT TO FIT SNUGLYAGAINST BOTH SUPPORTING STRUCTURE ABOVEAND CEILING RUNNER BELOW
4 TIGHT TURNS MINIMUM WITHIN 1 1/2" AT EACHEND OF DIAGONAL WIRE, TYPICAL
CROSS RUNNER
11 GAUGE WIRE BRACING, TYPICAL IN 4 DIRECTIONS,KEEP 6" CLEAR OF ANY UNBRACED HORIZONTALPIPING OR DUCTWORK
12 GA. VERTICAL WIREHANGER
MAINRUNNER OR UP TO 6'-8" USE: 3 1/2" x 1 1/4" 25 GA.
STEEL STUD ATTACHED TO RUNNERWITH 2-#10 SCREWS AND STRUCTUREABOVE WITH 3/16" DIAMETER POWDERDRIVEN PIN OR 2-#10 SCREWS
SEALANT (BOTH SIDES)
5/8" GYPSUM BOARD
(2) 3 5/8" METAL STUDS
TEMPEREDGLASS
EXISTING STORE FRONT FRAMING
EXISTING WINDOW SILL
EXISTING WINDOW SILL
PROVIDE NEW STOREFRONTFRAMING TO MATCH EXISTING.CONTRACTOR HAS OPTION TOREUSE EXISTING FRAMING IF ABLETO BE SALVAGED AND IN GOODCONDITION.
SEALANT
SEALANT
3-5/8" METAL STUDSBRACING @ 48" O.C.
SUSPENDEDACOUSTICALPANEL CEILINGSYSTEM
NOTE:REFER TO REFLECTED CEILING PLANFOR BULKHEAD LOCATION AND SIZES.
VARIES
LINE OFPARTITION WALL
5/8" GYP. BOARD
METAL EDGE BEAD
METAL STUDSCORNER ANGLE
3 5/8" METALSTUDS @24" O.C.
3 5/8" METALSTUDS @ 24" O.C.
ELEV., REFER TOCEILING PLAN
ELEV., REFER TOCEILING PLAN
6" SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
SUSPENSIONWIRE
SUSPENDEDACOUSTICALCEILINGPANEL
SUSPENDEDGYPSUMBOARD
SUSPENDEDGYPSUM BOARDCEILING SYSTEM
6" CEILINGTRANSITIONTRIM
SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
SUSPENSIONWIRE
SUSPENDEDACOUSTICALCEILING PANEL
ELEV., REFER TOCEILING PLAN
ACOUTICAL /GYPSUM BOARDCEILINGTRANSITION TRIM
REFLECTED CEILING PLAN REFERENCE NOTES:PROVIDE ADDITIONAL CEILING GRID CROSS TEE AS REQUIRED TOACCOMMODATE LIGHT FIXTURE.
CUT DOWN 2X4 TILE.
REMOVE AND REINSTALL EXISTING CEILING GRID AS REQUIRED FORINSTALLATION OF NEW CONSTRUCTION.
NEW BLINDS TO MATCH EXISTING AS APPROVED BY ARCHITECT.
FACE OF BULKHEAD TO BE [PT2]. UNDERSIDE OF BULKHEAD TO BE[PT5].
FACE AND UNDERSIDE OF BULKHEAD TO BE PAINTED [PT5].
COORDINATE LIGHT FIXTURE LOCATION WITH ARCHITECT PRIOR TOINSTALLATION.
CONFIRM THIS WALL EXTENDS TO DECK ABOVE. SEAL ALLPENETRATIONS AS REQUIRED AND APPLY ACOUSTIC CAULKING.
MAINTAIN OR EXTEND WALL ABOVE TO FLOOR DECK ABOVE ANDSEAL ALL PENETRATIONS.
1
2
3
4
5
6
7
8
9
GENERALREFLECTED CEILING PLAN NOTES:
PROVIDE CONTROL JOINTS OR OTHER ISOLATING MEANS IN GYPSUMBOARD PANELS WHERE: (A) PARTITION, FURRING, SOFFIT, BULKHEAD, ORCEILING ABUTS A STRUCTURAL ELEMENT OR DISSIMILAR WALL ORCEILING, (B) CONSTRUCTION CHANGES WITHIN PLANE OF PARTITION ORCEILING, (C) PARTITION, FURRING SOFFIT, BULKHEAD OR CEILING RUNEXCEEDS 30'-0", (D) AS NOTED.
MINIMUM DISTANCE FROM A WALL SURFACE TO THE NEAREST CEILINGGRID TEE SHALL BE 6".
WALLS INDICATED ; SHALL BE METAL STUDS, 5/8"GYPSUM BOARD ON ONE SIDE AND SOUND INSULATION SHALL END 6"ABOVE CEILING.
REFER TO A1.1 FOR ALL ACOUSTICAL CEILING PERIMETER CONDITIONS.
REFER TO A3.1 FOR CEILING FINISH INFORMATION.
1.
2.
3.
4.
5.
GENERAL FLOOR PLAN NOTES:ALL DIMENSIONS ON FLOOR PLANS ARE FROM FACE OF FINISH GYPSUMBOARD UNLESS NOTED OTHERWISE.
PROVIDE WOOD BLOCKING IN WALLS AND CEILINGS AS REQUIRED FORINSTALLATION OF CASEWORK OR OTHER SURFACE MOUNTEDACCESSORIES AND/OR EQUIPMENT.
LOCATE HOLLOW METAL OR ALUMINUM DOOR FRAMES 4" FROM ADJACENTWALL, UNLESS NOTED OTHERWISE. PROVIDE MINIMUM OF TWO (2) 20 GAUGEMETAL STUDS AT HEAD AND JAMB OF DOOR OPENINGS.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS THAT ARE SHOWN ON THEDRAWING.
FIRESTOPPING SHALL BE INSTALLED AT ALL PENETRATIONS OF THE FIRE-RATED WALLS AND MEET THE REQUIREMENTS OF THE FIRE-RATING OF THEWALL. THE FIRE STOPPING PRODUCTS SHALL BE "HILTI, INC." AND INSTALLEDPER THE MANUFACTURER'S INSTRUCTIONS WITH CERTIFIED INSTALLERS.
FIELD VERIFY ALL DIMENSIONS BEFORE FABRICATION OR INSTALLATION OFSHELVING AND MILLWORK.
ALL WALLS TO BE TYPE G3.B.1 UNLESS NOTED OTHERWISE.
FURNITURE SHOWN FOR PLANNING PURPOSES ONLY. FURNITURE IS NOT INCONTRACT.
1.
2.
3.
4.
5.
6.
7.
DNI
AI AN
No. AR10100128
STATE OF
GER
RTSI EDE
ARCH I T E
CT
JACK
SON R
ICHARDFABER
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
A1.1
FLOOR PLANS, PLAN DETAILS
1/8" = 1'-0"FIRST FLOOR PLAN
2'0' 4' 8'
North
1/8" = 1'-0"FIRST FLOOR REFLECTED CEILING PLAN
2'0' 4' 8'
North
1 1/2" = 1'-0"TYP. ACOUSTICAL CEILING EDGE DETAIL
3" = 1'-0"TYP. CEILING CONTROL JOINT (CJ)
1 1/2" = 1'-0"5 BULKHEAD DETAIL
1 1/2" = 1'-0"2 BULKHEAD DETAIL
1 1/2" = 1'-0"TYP. SUSP. ACOUSTICAL CLG. HANGER ATTACHMENT
1 1/2" = 1'-0"TYP. SUSP. ACOUSTICAL CLG. LATERAL BRACING
1 1/2" = 1'-0"1 PLAN DETAIL
1 1/2" = 1'-0"4 BULKHEAD DETAIL
1" = 1'-0"3 BULKHEAD DETAIL
# Description Date
SCHEDULE
SEE
SCH
EDU
LE
SEE
C
SCHEDULE
SEE
SCH
EDU
LE
SEE
A
8"
8" 8"
1' -
0"
1/4" TEMP.GLASS
SCHEDULE
SEE
SCH
EDU
LE
SEE
B
3' -
5"2'
- 9"
6"
8"
FIXEDPANEL
1/4" TEMP.GLASS
FROSTED VINYL FILM APPLIED TO GLASS.
PAINT FRAME AS INDICATED ON FINISH PLAN. (BASE BID ONLY)
MATCH EXISTING DOOR STAIN/FINISH.
ALTERNATE NO. 1 - ALUMINUM FRAMES.
RELOCATED DOOR AND HOLLOW METAL FRAME FROM EXISTING OPENING 1086.
EXISTING FRAME TO REMAIN.
EXISTING TO REMAIN.
SUPPLIED IN FURNITURE PACKAGE.
1.
2.
3.
4.
5.
6.
7.
8.
NOTES:
8
A2.2
12
A2.2
FT1
14' - 10 1/2"
2"8'
- 8"
2"
9' -
0"
14
A2.2
2" EQ EQ 2" 3' - 0" 2" EQ EQ 2"
BUTT JOINT W/SEALANT (TYP.)
12
A2.2Sim
13
A2.2
FT3
12
A2.2
14
A2.2
8
A2.2
2
A2.2
11' - 7 7/16"
2"1'
- 10
"5'
- 8"
1' -
2"2"
4 1/2"
1' - 0"2" 3' - 0" 2" EQ EQ 2"
FIXED TRANSOMPANEL TO MATCHDOOR FINISH
FROSTEDVINYL FILMCLEAR
CLEAR
9' -
0"
Sim3
A2.2
13
A2.2
3
A2.2
14
A2.2
7
A2.2
FT4
2"
9' -
0"
2"1'
- 2"
5' -
8"1'
- 10
"2"
FROSTEDVINYLFILM
CLEAR
CLEAR
14
A2.2FT5
2"3' - 0"2"EQ.EQ.2"
9' -
0"
2"1'
- 10
"5'
- 8"
1' -
2"2"
FIXED TRANSOMPANEL TO MATCHDOOR FINISH
FROSTEDVINYL FILMCLEAR
CLEAR
REFER TO DETAILCALLOUT ON FLOORPLAN FOR JAMB DETAIL
REFER TO DETAIL CALLOUTON REFLECTED CEILINGPLAN FOR HEAD DETAIL
13
A2.2
3' -
8"3'
- 6"
7' -
2"
FT6
8' - 10 3/8"
2"2"
2"
11
A2.2
10
A2.2
FT2
1
A2.1
2
A2.1
2"8'
- 10
"
9' -
0"
FIXED TRANSOMPANEL TO MATCHDOOR FINISH
EQ 2' - 9" 2' - 9" 2' - 9" EQ
EQ 2' - 9" 2' - 9" 2' - 9" EQ
6
A2.1
PL1
PL1
SS1
FILLER TO MATCHADJACENT, TYP.
FILLER TO MATCHADJACENT, TYP.
1' - 9" 2' - 0" 1' - 9" 1"
1" 1' - 9" 2' - 0" 1' - 9" 1"
5' - 8"
6
A2.1
7
A2.1
PL1
PL1
SS1
FILLER TO MATCHADJACENT, TYP.
FILLER TO MATCHADJACENT, TYP.
6
A2.1
1" 3' - 0" 2' - 9" 3' - 0"
1"3' - 0"2' - 9"3' - 0"1"
8' - 11"
8' - 10"
PL1
PL1
SS1
FILLER TOMATCHADJACENT,TYP.
FILLER TOMATCHADJACENT,TYP.
1/2"
1' - 2"
3"2' - 0"
4"1/
2"
5"
3/4" PLASTICLAM. CLAD TOP
WOOD BLOCKINGSHELF BRACKETSBEYOND WITH CLIPS
1/2" PLASTIC LAM.CLAD BACK
3/4" PLASTIC LAM.CLAD ADJUSTABLESHELVING
3/4" PLASTIC LAM.CLAD BOTTOM
SOLID SURFACECOUNTERTOP
PLASTIC LAM. CLADDRAWER W/PULLSHELF BRACKETSBEYOND WITH CLIPS
1/2" PLAS. LAM.CLAD BACK
3/4" PLASTIC LAM.CLAD DOOR W/PULL
3/4" PLASTIC LAM. CLAD BASE
WOOD BLOCKING
7' -
0"
WIREPULL
BASE
WIREPULL2'
- 10
"1'
- 6"
2' -
8"
1 1/
2"
2' - 1"
3/4" PLASTIC LAM. CLADADJUSTABLE SHELVING
SEALANT
3/4" PLASTIC LAM.CLAD DOOR W/PULL
WOOD BLOCKING
1 1/
2"
1' - 2"
4"3/4" PLASTICLAM. CLAD TOP
WOOD BLOCKING
SHELF BRACKETSBEYOND WITH CLIPS
1/2" PLASTIC LAM.CLAD BACK
3/4" PLASTIC LAM.CLAD ADJUSTABLESHELVING
3/4" PLASTIC LAM.CLAD BOTTOM
SOLID SURFACECOUNTERTOP
7' -
0"
2' -
10"
1' -
6"2'
- 8"
1/2" PLAS. LAM.CLAD BACK
3/4" PLASTIC LAM.CLAD DOOR W/PULL
3/4" PLASTIC LAM.CLAD BASE
WOOD BLOCKING
1/2"
3"
2' - 0"BASE
WIRE PULL
WIREPULL
1 1/
2"
2' - 1"
3/4" PLASTIC LAM.CLAD DOOR W/PULL
SEALANT
WOOD BLOCKING
1" DIA. CHROME CLOSETROD WITH "STANLEY"CLOSET BAR BRACKET,CATALOG NO. CD 7089
WOOD BLOCKING
3/4" PLASTIC LAMINATESHELF AND SIDES
5' -
4"
A2.19
8"
1' - 6"
1 1/2"
1 1/
2"
BULLNOSE, PLASTICTRIM, COLOR SELECTEDBY ARCHITECT
5'-0
" A.F
.F.
2" RADIUS1" DIA. CHROME CLOSET RODWITH "STANLEY" CLOSET BARBRACKET, CATALOG NO. CD7089 3/4" PLASTIC LAMINATE
CLAD BACK PANEL(FINISH SIDE)
3/4" PLASTIC LAM. CLADFRAME (FINISH ALLEXPOSED SIDES)
PROVIDE CONT. WOODBLOCKING IN STUD WALL
3/4" PLASTIC LAMINATECLAD SHELF
4"
1 3/
4"
3"3/4"
GENERAL MILLWORK NOTES:PROVIDE AWI "PREMIUM" GRADE MILLWORK.
CABINET DEPTHS ARE FROM FACE OF GYPSUM BOARD TO OUTSIDE FACE OFCABINET DOOR. UNLESS NOTED OTHERWISE.
INSTALL PLASTIC LAMINATE CLAD FILLER AS REQUIRED. FINISH OF THE FILLERSHALL MATCH THE FINISH OF THE ADJACENT MILLWORK UNLESS NOTEDOTHERWISE.
ALL EXPOSED SURFACES OF MILLWORK SHALL RECEIVE PLASTIC LAMINATE.CONTACT ARCHITECT IN CASES OF CONFLICT REGARDING COLOR SELECTION.
1.
2.
3.
4.
HEADERFRAMING
5/8" GYPSUMBOARD
HOLLOWMETAL FRAME
JOINT SEALANT(BOTH SIDES)
METAL STUDS -3 -5/8" AT 16"O.C. UNO
GYPSUM BOARD- 5/8" UNO
HOLLOW METALFRAME
LINE OF INTERSECTINGWALL (TYPICAL WHEREOCCURS)
4" +
/-
DNI
AI AN
No. AR10100128
STATE OF
GER
RTSI EDE
ARCH I T E
CT
JACK
SON R
ICHARDFABER
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
A2.1
DOORS SCHEDULE, INTERIORELEVATIONS, DETAILS
DOOR SCHEDULE
Door NumberDoor Data Frame Data
Hardware Set Comments Door NumberFire Rating Type Material Width Height Thickness Glass Type Material Head Frame Depth Jamb1075 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT1 HM - 5 3/4" - 2 1, 4 10751076 - - 3' - 0" 7' - 0" 1 3/4" - - - - - - - 8 1076
1076-1 B WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT2 HM 1/A2.1 5 3/4" 2/A2.1 2 2 1076-11077 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT3 HM SEE RCP 5 3/4" - 3 1, 2, 4 10771078 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT5 HM SEE RCP 5 3/4" SEE PLAN 1 1, 2, 4 10781079 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT5 HM SEE RCP 5 3/4" SEE PLAN 1 1, 2, 4 10791080 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT5 HM SEE RCP 5 3/4" SEE PLAN 1 1, 2, 4 10801081 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT5 HM SEE RCP 5 3/4" SEE PLAN 1 1, 2, 4 10811082 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT5 HM SEE RCP 5 3/4" SEE PLAN 1 1, 2, 4 10821083 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT5 HM SEE RCP 5 3/4" SEE PLAN 1 1, 2, 4 10831084 A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT5 HM SEE RCP 5 3/4" SEE PLAN 1 1, 2, 4 1084
1085A A WOOD 3' - 0" 7' - 0" 1 3/4" TEMP - - - - - 1 1, 2, 6 1085A1085B C WOOD 3' - 0" 7' - 0" 1 3/4" - - - - - - 1 6 1085B
1086-1A C WOOD 3' - 0" 7' - 0" 1 3/4" - FT2 HM 1/A2.1 5 3/4" 2/A2.1 - 2, 3 1086-1A1086-1B B WOOD 3' - 0" 7' - 0" 1 3/4" TEMP - - - - - 4 3, 6 1086-1B1086-2A C WOOD 3' - 0" 7' - 0" 1 3/4" - FT2 HM 1/A2.1 2/A2.1 2 2, 5 1086-2A1086-2B B WOOD 3' - 0" 7' - 0" 1 3/4" TEMP FT2 HM 1/A2.1 5 3/4" 2/A2.1 4 - 1086-2B
1/4" = 1'-0"DOOR ELEVATIONS
1/4" = 1'-0"HOLLOW METAL FRAME ELEVATIONS
3/8" = 1'-0"3 INTERIOR ELEVATION - ROOM NO. 1077
3/8" = 1'-0"4 INTERIOR ELEVATION - ROOM NO. 1086-1
3/8" = 1'-0"5 INTERIOR ELEVATION - ROOM NO. 1086-2
3/4" = 1'-0"6 CASEWORK SECTION
3/4" = 1'-0"7 CASEWORK SECTION
3/4" = 1'-0"8 CASEWORK SECTION
3" = 1'-0"9 SECTION
3" = 1'-0"1 HEAD DETAIL
3" = 1'-0"2 JAMB DETAIL
# Description Date
5/8" GYPSUM BOARD
3 5/8" 20 GA. METALSTUDS
ALUMINUM FRAME
5/8" GYPSUM BOARD
3 5/8" 20 GA. METALSTUDS
HOLLOW METALFRAME
3/8" TEMP.GLAZING
3/8" TEMP.GLAZING
ALTERNATE #1 BASE BID
ALUMINUM FRAME
3/8" (TYP.) TEMP.GLAZING
HOLLOWMETAL FRAME
3/8" (TYP.) TEMP.GLAZING
BASE BIDALTERNATE #1
HEADERFRAMING
5/8" GYPSUMBOARD
ALUMINUMFRAME
ALERNATE #1
GYPSUM BOARD -5/8" UNO
METAL STUDS -6" AT 16" O.C.
JOINT SEALANT(BOTH SIDES)
HOLLOW METALFRAME
3/8" TEMP. GLAZING(TYP.)BASE BID
HEADERFRAMING
5/8" GYPSUMBOARD
ALUMINUMFRAME
HEADERFRAMING
5/8" GYPSUMBOARD
HOLLOW METALFRAME
BASE BID
3/8" TEMP.GLAZING
ALTERNATE #1
PLAN
SEE
ALUMINUMFRAME
5/8" GYPSUMBOARD
3 5/8" 20 GA.METAL STUDS
1/2" GYPSUMBOARD
.125" ALUMINUMTRIM
ALTERNATE #1
PLAN
SEE
HOLLOWMETAL FRAME
5/8" GYPSUMBOARD
5/8" GYPSUMBOARD
BASE BID3 5/8" 20 GA.METAL STUDS
3/8" TEMP.GLAZING
3/8" TEMP.GLAZING
3 5/8" 20 GA.METAL STUDS
5/8" GYPSUMBOARD
ALUMINUMFRAME
3 5/8" 20 GA.METAL STUDS5/8" GYPSUMBOARD
HOLLOW METALFRAME
3/8" TEMP.GLAZING
3/8" TEMP.GLAZING
ALTERNATE #1 BASE BID
HEADERFRAMING
5/8" GYPSUMBOARD
ALUMINUMFRAME
ALTERNATE #1
HEADERFRAMING
5/8" GYPSUMBOARD
HOLLOWMETAL FRAME
BASE BID
SUSPENDEDACOUSTICALPANELCEILING SYSTEM
HEADERFRAMING
5/8" GYPSUMBOARD
ALUMINUMFRAME
ALTERNATE #1
SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
HEADERFRAMING
HOLLOWMETAL FRAME
BASE BID
5/8" GYPSUMBOARD
PLAN
SEE
ALUMINUMFRAME
5/8" GYPSUMBOARD
3 5/8" 20 GA.METAL STUDS
1/2" GYPSUMBOARD
.125"ALUMINUMTRIM
ALTERNATE #1
PLAN
SEE
HOLLOWMETAL FRAME
5/8" GYPSUMBOARD
FRAME ANCHOR- MINIMUM 3 PERJAMB
5/8" GYPSUMBOARD
BASE BID
3 5/8" 20 GA.METAL STUDS
ALUMINUMFRAME
5/8" GYPSUMBOARD
3 5/8" 20 GA.METAL STUDS
WOODBLOCKING
ALTERNATE #1
HOLLOWMETALFRAME
5/8" GYPSUMBOARD
FRAMEANCHOR -MINIMUM 3PER JAMB
WOODBLOCKING
BASE BID
3/8" TEMP.GLAZING
3/8" TEMP.GLAZING
3/8" TEMP.GLAZING
HOLLOWMETALFRAME
.125"ALUMINUMTRIM
WOODBLOCKING
3 5/8" METALSTUDS
ALUMINUMFRAME
ALTERNATE #1 BASE BID
PLAN
SEE
ALUMINUMFRAME
5/8" GYPSUMBOARD
3 5/8" 20 GA.METAL STUDS
1/2" GYPSUMBOARD
.125"ALUMINUMTRIM
3/8" TEMP.GLAZING
PLAN
SEE
HOLLOWMETAL FRAME
5/8" GYPSUMBOARD
FRAME ANCHOR- MINIMUM 3 PERJAMB
5/8" GYPSUMBOARD
3 5/8" 20 GA.METAL STUDS
3/8" TEMP.GLAZING
HEADERFRAMING
5/8" GYPSUMBOARD
ALUMINUMFRAME
HEADERFRAMING
5/8" GYPSUMBOARD
HOLLOW METALFRAME
BASE BID
3/8" TEMP.GLAZING
JOINTSEALANT(BOTH SIDES)
JOINTSEALANT(BOTH SIDES)
ALTERNATE #1
SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
HEADERFRAMING
5/8" GYPSUMBOARD
ALUMINUMFRAME
SUSPENDEDACOUSTICAL PANELCEILING SYSTEM
HEADERFRAMING
5/8" GYPSUMBOARD
HOLLOWMETAL FRAME3/8" TEMP. GLAZING
ALERNATE #1 BASE BID
@ DOOR NO.1075
3 5/8" METALSTUDS @36" O.C.
@ DOOR NO.1075
3 5/8" METALSTUDS @36" O.C.
ALTERNATE #1 BASE BID
HOLLOWMETAL FRAME
3/8" TEMP.GLAZING (TYP.)
ALUMINUMFRAME
3/8" TEMP.GLAZING (TYP.)
DNI
AI AN
No. AR10100128
STATE OF
GER
RTSI EDE
ARCH I T E
CT
JACK
SON R
ICHARDFABER
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
A2.2
FRAME DETAILS
3" = 1'-0"11 JAMB DETAIL
3" = 1'-0"14 SILL DETAIL
3" = 1'-0"7 HEAD DETAIL
3" = 1'-0"9 HEAD DETAIL
3" = 1'-0"6 JAMB DETAIL
3" = 1'-0"12 JAMB DETAIL
3" = 1'-0"1 HEAD DETAIL
3" = 1'-0"2 HEAD DETAIL
3" = 1'-0"5 JAMB DETAIL
3" = 1'-0"3 JAMB DETAIL
3" = 1'-0"4 JAMB DETAIL
3" = 1'-0"10 HEAD DETAIL
3" = 1'-0"8 HEAD DETAIL
3" = 1'-0"13 DETAIL
# Description Date
WAITING1075
OPEN OFFICE1076
CONFERENCE1077
OFFICE1078
OFFICE1079
OFFICE1080
OFFICE1081
OFFICE1082
OFFICE1083
OFFICE1084
OFFICE1085
BREAK1086-1
STORAGE1086-2
VESTIBULE1087
CORR1074
CORR1076-1
CORR1076-2
WORK1076-3
WC
1
PT3 PT3 PT3 PT3
PT4
PT3
PT3
PT3
PT3
PT3 PT
4
EXIST EXTENTS
NEW
EXIST EXTENTS
NEW
EXIST EXTENTS
NEW
1
1
1
1
1
G.D.
G.D.
G.D.
G.D.
G.D.
G.D.
2
3
3
TILE CARPETING (096813)
TAG: CPT1MFG: MOHAWKSTYLE: HYPER EARTHCOLOR: BLUE SAPPHIRENMBR: 985INSTALL METHOD: MONOLITHICSIZE: 12"x36"
TAG: CPT2MFG: MOHAWKCOLCT: ICONIC EARTHSTYLE: DRIFTED GROUNDCOLOR: CLEAN SLATEINSTALL METHOD: REFER TO DETAILSSIZE: 12"x36"
RESILIENT TILE FLOOR (096519)
TAG: LVP1MFG: PATCRAFTCOLCT: METALLSTYLE: STUDIOCOLOR: TBDNUMBER: TBDSIZE: 12"x24"INSTALLATION METHOD: HERRINGBONE
WALLCOVERING (097200)
TAG: WC1MFG: SOURCE ONECOLCT: WOODSCOLOR: QUARTERED WHITE OAKNMBR: SWS-06
WALL PROTECTION (102600)
TAG: CG1MFG: ACROVYNSERIES: SM-FULL HEIGHT 1/4" RADIUS CORNERSIZE: 3" LEGxFULL WALL HEIGHT (TOP OF BASETO CEILING)COLOR: TBD
RESILIENT BASE AND ACCESSORIES (096513)
TAG: RB1MFG: JOHNSONITESTYLE: MANDALAYCOLOR: TBDSIZE: 4.5"H
INTERIOR PAINTING (099123)
TAG: PT1 (FIELD PAINT & DOOR FRAME)MFG: SHERWIN WILLIAMSCOLOR: TBDNMBR: TBD
TAG: PT2 (ACCENT PAINT)MFG: SHERWIN WILLIAMSCOLOR: TBDNMBR: TBD
TAG: PT3 (ACCENT PAINT)MFG: SHERWIN WILLIAMSCOLOR: TBDNMBR: TBD
TAG: PT4 (ACCENT PAINT)MFG: SHERWIN WILLIAMSCOLOR: TBDNMBR: TBD
TAG: PT5 (CEILING PAINT)MFG: SHERWIN WILLIAMSCOLOR: CEILING BRIGHT WHITENMBR: TBD
FINISH MATERIALS LEGENDPLASTIC LAMINATE (064023)
TAG: PL1MFG: WILSONARTCOLOR: NATURAL RECONNMBR: 7996-38FINISH: FINE VELVET
SOLID SURFACE (064023)
TAG: SS1MFG: WILSONARTCOLOR: YUKON RIVERSTONE
ACOUSTICAL PANEL CEILING (095113)
TAG: APC1MFG: CERTAINTEEDSTYLE: PERFORMA ADAGIOITEM NMBR: 1662F-IFO-1EDGE STYLE: SQUARE TEGULARSIZE: 24"x24"x1 1/2"FINISH: WHITEGRID: ARMSTRONG 9/16" INTERLUDE XL HRCTILE AND GRID COLOR: WHITE
ROLLER WINDOW SHADES (122413)
TAG: RWS1MFG:SERIES:STYLE:COLOR:
HORIZONTAL LOUVER BLINDS (122113)
TAG: HLB1MFG:SERIES:STYLE:COLOR:
CARPET
JOHNSONITE SLIM LINE SLTTRANSITION, COLOR BY ARCHITECT
RESILIENT FLOOR
CARPET TO RESILIENT
DNI
AI AN
No. AR10100128
STATE OF
GER
RTSI EDE
ARCH I T E
CT
JACK
SON R
ICHARDFABER
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
A3.1
FIRST FLOOR FINISH PLANAND SCHEDULE
1/4" = 1'-0"FIRST FLOOR FINISH PLAN
ROOM FINISH SCHEDULE
RoomFloor Finish Base Finish
Wall Finish CeilingFinish Comments NumberNumber Name Wall A Wall B Wall C Wall D
1075 WAITING CPT1, CPT2 RB1 -- -- PT1, WC1 PT1, PT1 APC1, GYP. 10751076 OPEN OFFICE CPT1,CPT2 RB1 -- PT1 PT1, WC1 PT1 APC1, GYP. 1076
1076-1 CORR CPT1, CPT2 RB1 PT1 -- PT1, WC1 PT1 APC1, GYP. 1076-11076-2 CORR CPT1, CPT2 RB1 PT1 PT1 PT1 PT1 APC1 1076-21076-3 WORK CPT1, CPT2 RB1 -- PT1 PT1 PT1 APC1 1076-31077 CONFERENCE CPT2 RB1 PT1 PT3 PT4 PT1 APC1 10771078 OFFICE CPT2 RB1 -- PT3 PT1 PT1 APC1 10781079 OFFICE CPT2 RB1 -- PT3 PT1 PT1 APC1 10791080 OFFICE CPT2 RB1 -- PT3 PT1 PT1 APC1 10801081 OFFICE CPT2 RB1 PT1 PT1 -- PT3 APC1 10811082 OFFICE CPT2 RB1 PT1 PT1 -- PT3 APC1 10821083 OFFICE CPT2 RB1 PT1 PT1 -- PT3 APC1 10831084 OFFICE CPT2 RB1 PT1 PT1 -- PT3 APC1 10841085 OFFICE CPT2 RB1 PT1 PT1 PT1 PT3 APC1 1085
1086-1 BREAK LVP1 RB1 PT1 PT1 PT4 PT1 APC1 1086-11086-2 STORAGE CPT2 RB1 PT1 PT1 PT1 PT1 APC1 1086-2
12" = 1'-0"1 TYPICAL FLOOR TRANSITIONS
FINISH PLAN REFERENCE NOTES1 INSTALL FLOORING IN BLEND [CPT1] (30%), [CPT2] (70%).
ARCHITECT TO PROVIDE FUTURE DETAILS WITH SUBMITTALS.
2 PROVIDE VERTICAL CONTROL JOINTS ON WALL. VERTICALCONTROL JOINTS PAINT TO MATCH [WC1]. CONFIRM PAINTWITH ARCHITECT.
3 RE-INSTALL EXISTING CERAMIC TILE BASE. MATCH EXISTINGGROUT.
GENERAL INTERIOR FINISH NOTESA. ALL INTERIORS NOTES, SCHEDULES AND LEGENDS REFERENCE ABCD LEGEND. REFER TO VIEW HEADER OF ROOM FINISH SCEDULE.
B. PROVIDE RESILIENT OR METAL TRANSITION STRIP AT ALL FLOORING MATERIAL JUNCTURES. WHERE MATERIALS TRANSITION AT DOORSCENTER OF TRANSITION TO BE LOCATED ON CENTER OF DOOR. REFER TO DETAIL [1/A3.1] FOR TYPICAL FLOOR MATERIAL TRANSITIONS.COLOR SELECTED BY ARCHITECT FROM MANUFACTURES FULL RANGE OF COLORS.
C. ALL EXPOSED GYP. CEILINGS AS WELL AS UNDERSIDE AND FACES OF BULKHEADS, AND SOFFITS TO BE PAINTED, REFER TO FINISHSCHEDULE FOR CEILING FINISHES AND REFLECTED CEILING PLANS FOR CEILING MATERIAL EXTENTS AND FINISH REQUIREMENTS.COORDINATE ANY PAINT FINISHES WITH ARCHITECT IN FIELD BEFORE PROCEEDING WITH FINISH WORK.
D. REFER TO DOOR SCHEDULE AND FINISH FLOOR PLAN FOR CLARIFICATION OF DOOR MATERIALS. ALL HOLLOW METAL DOOR FRAMES TOBE PAINTED [PT1].
E. ALL EXPOSED GYP WALLS TO BE PAINTED UNLESS NOTED OTHERWISE.
F. ALL DIFFUSERS TO BE PAINTED TO MATCH ADJACENT WALL FINISH, VERIFY COLOR WITH ARCHITECT IN FIELD.
G. PAINT FINISH SHEEN SCHEDULE: WALLS- EGGSHELL ACRYLIC LATEX; HOLLOW METAL DOORS AND FRAMES- SEMI GLOSS ENAMEL;CEILING FLAT ACRYLIC LATEX UNLESS NOTED OTHERWISE.
I. REFER TO FINISH FLOOR PLANS FOR PAINT ACCENT LOCATIONS AND FLOOR FINISH PATTERNS AND EXTENTS.
J. REFER TO INTERIOR ELEVATIONS FOR CASEWORK FINISH LOCATION.
K. WHERE NEW FINISHES WOULD MATCH EXISTING FINISHES, OR NEW FINISHES ARE NOT REQUIRED, MAINTAIN EXISTING FINISHES WHEREPOSSIBLE DURING DEMOLITION AND CONSTRUCTION PHASE FOR REUSE. PATCH AND MATCH EXISTING FINISHES WHERE DISTURBED BYCONSTRUCTION.
L. PROVIDE WALL PROTECTION 9CORNER GUARDS) WHERE INDICATED ON FLOOR PLANS.
M. CONFIRM ACCENT PAINT LOCATION AND COLOR WITH ARCHITECT IN FIELD BEFORE PROCEEDING WITH FINISH WORK.
N. EXISTING ROOM FINISHES SHALL BE PROTECTED DURING THE CONSTRUCTION. WHERE DAMAGED, THEY SHALL BE PATCHED ANDREPAIRED AS REQUIRED TO MATCH THE SURROUNDING AND/OR EXISTING FINISHES.
O. NEW CONSTRUCTION SHALL BE FINISHED AS REQUIRED TO MATCH THE SURROUNDING EXISTING FINISHES UNLESS NOTED OTHERWISE.PATCH AND REPAIR EXISTING WALLS AS REQUIRED BEFORE THE INSTALLATION OF THE SCHEDULED NEW FINISHES.
# Description Date
5678
F
G
H
K
P1
5678
F
G
H
K
P2
PLUMBING FIXTURE LIST
SK-1 SINK ELKAY LR-1918, 19" x 18" x 7-1/2" DEEP SINGLE COMPARTMENT 18GAUGE STAINLESS STEEL SELF-RIM COUNTER INSERT THREE HOLELEDGE SINK. FURNISH WITH CHICAGO FAUCET 201A WITH L8 SWINGSPOUT, 369 HANDLES, 2.2 GPM AERATOR, ELKAY LK-99 STAINLESS STEELSTRAINER WITH TAILPIECE, CHROME-PLATED P-TRAP WITH CLEANOUTAND ESCUTCHEON, HAND WHEEL STOP WALL SUPPLIES AND RISERS.
RB-1 OATEY 38811 REFRIGERATOR CONNECTION BOX WITH VALVE. COORDINATEMOUNTING HEIGHT WITH EQUIPMENT.
FIXTURE FINAL CONNECTION SCHEDULE
LAVATORY OR SINK
NOTES:1. ALL FINAL CONNECTIONS TO FIXTURES SHALL BE AS INDICATED ABOVE UNLESS SPECIFICALLY SHOWN OTHERWISE ON THE
DRAWINGS.
FIXTURE COLD WATERHOT WATER WASTE
1-1/2"1/2" 1/2"
REMARKSVENT
1-1/2"
5678
F
G
H
K
4"
2"
P3
P7
5678
F
G
H
K
RB-1SK-1
1 1/2" 1/2"
3/4" 3/4"
P4
P5
1 1/2"
P6
2"
1 1/2"
SK-1
4"
1 1/2"
2"
SUBSTITUTIONS SHALL BE MADE ONLY WITH APPROVAL OF ENGINEER.
INDIANA PLUMBING CODEINDIANA MECHANICAL CODEINDIANA BUILDING CODE
CONTRACTOR SHALL MAKE MODIFICATIONS IN THE INSTALLATION SO ALLEQUIPMENT AND MATERIALS FIT PROPERLY AND CAN BE SERVICED.
INDICATE GENERAL ARRANGEMENT OF EQUIPMENT, FIXTURES AND PIPING.THE PLUMBING DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO
OSHA
GENERAL:
PLUMBING SPECIFICATIONS:
MIN. ROD SIZE
TIN ANTIMONY.
PIPE SIZE MAX. SPAN
CONFORMING TO ASTM B 88. FITTINGS SHALL BE WROUGHT COPPER,
3/8"5 FT.1/2" & 3/4"
SUBJECT PIPING SYSTEM TO A HYDROSTATIC PRESSURE TEST OF AT LEAST50 PSIG ABOVE OPERATING PRESSURE FOR 10 MINUTES PRIOR TO INSTALLINGINSULATION. DO NOT EXCEED PRESSURE RATING OF PIPING SYSTEM.
ALL DOMESTIC WATER PIPING SHALL BE COPPER PIPE, TYPE L
ASTM B16.22. JOINING MATERIAL SHALL BE SOLDER, ASTM B 32, 95-5
SANITARY PIPING:
CONTRACTOR SHALL SUBMIT FOUR (4) COPIES OF EQUIPMENT, FIXTURES,TRIM AND MATERIAL INFORMATION TO THE ENGINEER. INCLUDED IN THEINFORMATION SHALL BE PERFORMANCE DATA, RATINGS,WIRINGDIAGRAMS, MAINTENANCE INSTRUCTIONS, AND PARTS LIST.
ALL DOMESTIC WATER VALVES SHALL BE BALL TYPE, 150 PSIG SWP, TWOPIECE, BRONZE BODY, FULL PORT, AND STAINLESS STEEL TRIM.
SUBJECT PIPING SYSTEM TO A HYDROSTATIC PRESSURE TEST OF 10FT. OF WATER.
P.1 ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLENATIONAL, STATE AND LOCAL CODES AND REGULATIONS INCLUDING, BUTNOT LIMITED TO THE FOLLOWING:
P.2
P.3
P.4
DOMESTIC WATER PIPING:
P.5
P.6
P.7
INSULATION THICKNESSSERVICE PIPE SIZE
COLD WATER 1" AND SMALLER1-1/4" AND LARGER
1/2"1"
HOT WATER ANDRECIRCULATED HOT
1-1/2" AND SMALLER2" AND LARGER
1"1-1/2"
WATER
COPPER WATER PIPING SHALL BE SUPPORTED WITH ADJUSTABLE STEELCLEVIS HANGERS ACCORDING TO THE FOLLOWING:
P.8
P.9
P.10 SANITARY PIPING SHALL BE SOLID WALL PVC SCHEDULE 40 WITHSOLVENT WELDED JOINTS. SLOPE PIPING 1 PERCENT IN DIRECTION OF FLOW.
DOMESTIC WATER PIPING INSULATION SHALL BE MINERAL-FIBER,PREFORMED PIPE, TYPE 1., WITH FACTORY APPLIED ALL SERVICE JACKET.PROVIDE PIPE INSULATION SHIELDS AT EACH PIPE HANGER. INSTALL INACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS ACCORDING TOTHE FOLLOWING:
P.12
P.14 1-1/2" TALL PIPE LABELS SHALL BE COLOR CODED WITH LETTERINGINDICATED SERVICE AND FLOW DIRECTION. PROVIDE PIPE LABELS EVERY 25FEET AND AT VALVES, BRANCHES AND EQUIPMENT. EQUIPMENT LABELSSHALL BE BRASS WITH MINIMUM 1/4" LETTER SIZE. PERMANENTLY FASTENEQUIPMENT LABEL WHERE ACCESSIBLE AND VISIBLE.
ALL INSTALLATIONS SHALL BE SEISMICALLY SECURED.
MISC.
CONTRACTOR SHALL NOTIFY OWNER IN WRITING 3 DAYS IN ADVANCE FORALL UTILITY DISRUPTIONS. CONTRACTOR SHALL COORDINATECONSTRUCTION WITH THE OWNER AND ENGINEER. THE PROJECT SHALL BEPHASED TO MINIMIZE THE DISRUPTION TO THE FACILITIES.
MIN. ROD SIZEPIPE SIZE MAX. SPAN
3/8"4 FT.
P.13 VENT PIPING SHALL BE SUPPORTED WITH ADJUSTABLE STEELCLEVIS HANGERS ACCORDING TO THE FOLLOWING:
1-1/2" & 2"
P.15
P.16
P.11 VENT PIPING SHALL BE CAST IRON OR COPPER.
RELOCATE SPRINKLER HEADS AND PIPING AS REQUIRED FOR NEWINSTALLATIONS. ALL FIRE PROTECTION PIPING WORK / REWORK SHALL BEPERFORMED BY THE PIPING CONTRACTOR.
P.17
INDIANA FIRE CODE NFPA
R
R
ED
A
N
PE10505044
PROF I N
O
E
SSI
LAN
D I
E
NA
STATE OF
No.
EN
GI
RE
R
A
T
GAY E
NWS
TSI
.
RE
NE IH
T
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
03/14/2017
P1.1
PLUMBING PLANS
RWSRWS CSM
2'0' 4' 8'
North
1/8" = 1'-0"
FIRST FLOOR PLUMBING DEMOLITION PLAN
2'0' 4' 8'
North
1/8" = 1'-0"
LOWER LEVEL PLUMBING DEMOLITION PLAN
PLAN NOTES:P1 REMOVE SINK AND ASSOCIATED WATER AND VENT LINES TO WHERE
SHOWN.
P2 REMOVE 2" WASTE UP TO SINK AND TO WHERE SHOWN.
1/8" = 1'-0"
LOWER LEVEL PLUMBING PLAN 1/8" = 1'-0"
FIRST FLOOR PLUMBING PLAN
2'0' 4' 8'
North
2'0' 4' 8'
North
P3 2" WASTE UP TO SINK.
P4 INSTALL CHECK VALVE AND BALANCING VALVE IN EXISTING 3/4"HWR LINE. BALANCE TO 0.5 GPM.
P5 BALANCE 1/2" HWR BALANCING VALVE TO 0.5 GPM.
SANITARY RISER DIAGRAM
P6 REWORK / MODIFY EXISTING SPRINKLER PIPING AND HEADS ASREQUIRED. REFER TO REFLECTED CEILING PLAN FOR TYPES ANDHEIGHTS OF CEILINGS. PROVIDE CONCEALED TYPE HEADSLOCATED IN HARD CEILINGS AND BULKHEADS. SPRINKLERPROJECT AREA LIGHT HAZARD.
P7 REMOVE AND REINSTALL CEILING AS REQUIRED FORINSTALLATION OF PIPING. CONTRACTOR SHALL REPLACE ANYDAMAGED CEILING TILES THAT OCCUR DURING INSTALLATION ATTHEIR EXPENSE.
# Description Date
T
T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
5678
F
G
H
K
16"ø
14"ø
12"ø10"ø
12"x
10"
18"x12"10"ø
6"ø
16"x12"
16"x12"
6"ø
7"ø
8"ø
8"ø
6"ø
12"x12"
10"ø
12"x
12"
30"x18"
12"x
12"
10"ø
8"ø
6"ø
6"ø
16"x12"
16"x12"
16"x12"
10"ø
6"ø
8"ø
10"x10"
12"x10"
12"x12"
10"ø
1077
10781079
1080
1081
1082
1083
1084
1076-2
1076
10751086-2
1086-1
1085
10"ø
10"ø
10"ø
10"ø
10"ø
10"ø
R-1
R-1
S-2220
S-3290
S-3290
S-3210
S-3320
S-3240
R-1S-2220 S-3
230
S-3250
S-3250
R-1
R-1
S-3250
S-3250
S-3250
VAV-1076
12"x
12"
6"ø
R-1R-1
R-1
R-1
10"ø
S-4370
S-4370
12"ø
16"x14"
R-1
R-1
R-1
10"ø
8"ø
8"ø
8"ø
8"ø
VAV-1077B
16"x12"
S-3320
10"ø
S-2230
S-2230
S-2230
R-1
VAV-1086
VAV-1075
VV-1085
VV-1084
VV-1083
VV-1082
VV-1081
VV-1079
VV-1077
12"ø
S-2220
5678
F
G
H
K
M4
M4
M4
M4
M4 M4
M4
M4M4
M3
M4M4
M4
M4
M4M4
M4
M4
M4
M4
10"ø
M4
M4
M4
M4
M4
M4
10"ø
10"ø
10"ø
10"ø
5678
F
G
H
K
VAV-1077BVV-1079
VV-1077
VAV-1076
VAV-1086
VAV-1075
VAV-1075
VAV-1077
VAV-1077B
VAV-1079
VAV-1076
VAV-1086
1075
1076
10771078107910801081
1082
1083
1084
1085 1086-1 1086-2
1076-1
1076-2
1076-3
3/4" 3/4"
1 1/4" 1 1/4"
3/4" 3/4"
M5
M5
M5
M5
M5
M5
M5
M5
5678
F
G
H
K
M2
M3
M2
M1
M1M1
M1
M1
M1
M1
R
R
ED
A
N
PE10505044
PROF I N
O
E
SSI
LAN
D I
E
NA
STATE OF
No.
EN
GI
RE
R
A
T
GAY E
NWS
TSI
.
RE
NE IH
T
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
03/14/2017
M1.1
FIRST FLOOR HVAC PLAN
RWSRWS CSM
2'0' 4' 8'
North
NO SCALE
LOW PRESSURE DUCT LEGEND
TEMPERATURE SENSOR (ALIGN SPACEABOVE LIGHT SWITCH - COORDINATEALL LOCATIONS WITH ARCHITECT)
T
FD
SD
F/S
D
RETURN/EXHAUSTAIR DUCT DOWN
D
R RADIUS TURN, R/D = 1.5
FLAT ON BOTTOMTRANSITION
FLAT ON TOPTRANSITION
WHERE 1.5 R/D RADIUSTURNS ARE NOT ALLOWEDDUE TO INADEQUATE SPACE,PROVIDE A SQUARE ELBOWWITH TURNING VANES
FO
T
FO
B
SQUARE TOROUND TRANSITION
FLEX. INSUL DUCT
CEILING MTD.SUPPLY GRILLE
ROUND DUCT,EXTERNALLY INSULATED
FIRE DAMPER
SMOKE DAMPER
FIRE/SMOKEDAMPER
SIDEWALL DUCTMOUNTED SUPPLYOR RETURN GRILLE
45° BRANCH CONN.W/ VOL DAMPER
RECTANGULAR SUPPLYDUCT #"x#" DUCT SIZEFIRST # = DUCT WIDTHSECOND # = DUCT DEPTH.SIZES SHOWN ARE SHEET METALDIMENSIONS, NO INCREASE INSIZE REQ'D FOR DUCT LINER.
SUPPLY AIRDUCT DOWN
ø ROUND DUCT,EXTERNALLY INSULATED
AIR FLOWDIRECTIONARROW
SUPPLY AIRDUCT UP
RECTANGULAR RETURNDUCT #"x#" DUCT SIZEFIRST # = DUCT WIDTHSECOND # = DUCT DEPTH.SIZES SHOWN ARE SHEET METALDIMENSIONS, NO INCREASE INSIZE REQ'D FOR DUCT LINER.
CEILING MTD. RETURNOR EXHAUST GRILLE
45° BRANCH CONNECTIONW/ VOLUME DAMPER
RETURN/EXHAUSTDUCT UP
GENERAL NOTES:A. ALL CONTROL WIRING SHALL BE BY MECHANICAL CONTRACTOR.
B. ALL THERMOSTATS SHALL BE MOUNTED AT 60" AF.F. UNLESS NOTEDOTHERWISE. WHEN AN ELECTRICAL SWITHC OR OTHER DEVICE ISMOUNTED IN THE SAME LOCATION AS A THEMOSTAT. ALL DEVICESSHALL BE ALIGNED VERTICALLY. VERIFY ALL THERMOSTATLOCATIONS WITH ARCHITCT PRIPR TO INSULATION.
C. ALL RECTANGULAR SUPPLY AND RETURN DUCTWORK SHALL BEINTERNALLY LINED (DUCT DOES NOT NEED TO BE INCREASED FORLINER).
D. ALL ROUND SUPPLY AND ROUND RETURN DUCTWORK SHALL BEEXTERNALLY INSULATED.
E. COORDINATE PIPE ROUTING WITH ALL TRADES. EQUIPMENT SHALLMAINTAIN MANUFACTURER RECOMMENDED CLEARANCES ASREQUIRED.
F. REFERENCE REFLECTED CEILING PLAN FOR TYPES AND HEIGHTS OFCEILINGS.
G. ALL HWS AND HWR PIPING SHALL BE 3/4" UNLESS OTHERWISE NOTED.
H. ALL CONTROL VALVES SHALL BE 2-WAY UNLESS NOTED OTHERWISE.
I. CERTIFIED TEST AND BALANCE CONTRACTOR SHALL BALANCE NEWAND EXISTING DIFFUSERS AND VAV BOXES TO NOTED AIRFLOWS ANDWATER FLOW RATES.
1/8" = 1'-0"
FIRST FLOOR HVAC PLAN
PLAN NOTES:M1 REMOVE AND RELOCATE THERMOSTAT.
1/8" = 1'-0"
FIRST FLOOR HVAC DEMOLITION PLAN
2'0' 4' 8'
North
1/8" = 1'-0"
FIRST FLOOR HVAC PIPING PLAN 1/8" = 1'-0"
FIRST FLOOR HVAC PIPING DEMOLITION PLAN
2'0' 4' 8'
North
2'0' 4' 8'
North
M2 REMOVE TEMPERATURE SENSOR.
M3 REMOVE FAN-POWERED VAV BOX AND ASSOCIATEDDUCTWORK, PIPING AND CONTROLS COMPLETE.
M4 REMOVE DIFFUSER OR GRILLE AND DUCT TO WHERE SHOWN.
M5 RELOCATED THERMOSTAT.
# Description Date
DIFFUSER PANEL
SEAL INSULATION TO EDGEOF DIFFUSER PLENUM
EXTERNALLY 1" INSULATEDDIFFUSER SHELL IN FIELD
INSULATED FLEX DUCT (MAX. 5')
SUPPORT FLEX DUCT WHEN NEEDEDSO INSIDE BEND RADIUS IS MAINTAINED
SEE PLANSFOR SIZE
SINGLE DUCT AIR TERMINAL TEMPERATURECONTROL DIAGRAM AND SEQUENCE OF OPERATION
DPT
TSA.I. - ZONE TEMPERATURE
TE
A.I. - LEAVING AIR TEMPERATURE
THE SINGLE DUCT AIR TERMINAL CONTROLLER SHALL MONITOR ZONE TEMPERATURE, LEAVINGAIR TEMPERATURE, INLET AIR PRESSURE TRANSDUCER, AND ZONE TEMPERATURE SETPOINT
C
H
M
HWR
HWS
A.O. - REHEAT COIL CONTROL VALVEM
A.O. - AIR DAMPER
A.I. - AIRFLOW
EACH CONTROLLER SHALL HAVE A USER DEFINED OCCUPIED/UNOCCUPIED MODE SCHEDULE.OCCUPIED AND UNOCCUPIED MODES SHALL HAVE INDIVIDUAL HEATING AND COOLING ZONETEMPERATURE SETPOINTS.
DURING OCCUPIED MODE, THE CONTROLLER SHALL CALCULATE THE AIRFLOW REQUIRED BASED ON ZONETEMPERATURE, ZONE TEMPERATURE SETPOINT, AND LEAVING AIR TEMPERATURE. THE CONTROLLERSHALL MODULATE THE INLET AIR DAMPER BETWEEN MINIMUM AND MAXIMUM AIRFLOW SETPOINTS TOMAINTAIN THE CALCULATED AIRFLOW BASED ON THE INLET AIR PRESSURE TRANSDUCER. IF ZONETEMPERATURE FALLS BELOW THE ZONE TEMPERATURE SETPOINT, THE CONTROLLER SHALL MODULATETHE INLET AIR DAMPER TO MAINTAIN THE HEATING AIRFLOW SETPOINT AND THE CONTROLLER SHALLMODULATE THE HOT WATER CONTROL VALVE TO MAINTAIN THE ZONE TEMPERATURE SETPOINT. THELEAVING AIR TEMPERATURE SHALL NOT BE ALLOWED TO EXCEED THE LEAVING AIR TEMPERATURE LIMIT.
DURING UNOCCUPIED MODE, THE CONTROLLER SHALL CALCULATE THE AIRFLOW REQUESTEDBASED ON ZONE TEMPERATURE, UNOCCUPIED ZONE TEMPERATURE SETPOINT, AND LEAVING AIRTEMPERATURE. THE CONTROLLER SHALL MODULATE THE INLET AIR DAMPER BETWEEN CLOSEDPOSITION AND MAXIMUM AIRFLOW SETPOINT TO MAINTAIN THE CALCULATED AIRFLOW BASED ONTHE INLET AIR PRESSURE TRANSDUCER. IF TEMPERATURE FALLS BELOW THE UNOCCUPIED ZONETEMPERATURE SETPOINT, THE CONTROLLER SHALL MODULATE THE INLET AIR DAMPER TO MAINTAINTHE HEATING AIRFLOW SETPOINT AND THE CONTROLLER SHALL MODULATE THE HOT WATERCONTROL VALVE TO MAINTAIN THE UNOCCUPIED ZONE TEMPERATURE SETPOINT. THE LEAVING AIRTEMPERATURE SHALL NOT BE ALLOWED TO EXCEED THE LEAVING AIR TEMPERATURE LIMIT.
THE CONTROLLER SHALL PROVIDE ALARMS TO THE FMS AS FOLLOWS :
HIGH ZONE TEMPERATURE/LOW ZONE TEMPERATURE - ALARM AT THE OPERATOR INTERFACE IFZONE TEMPERATURE IS LESS THAN OR GREATER THAN THE COOLING/HEATING ZONE SETPOINT BYAN OPERATOR DEFINED AMOUNT (°F).
HIGH DISCHARGE TEMPERATURE/LOW DISCHARGE TEMPERATURE - ALARM AT THE OPERATORINTERFACE IF TERMINAL LEAVING AIR TEMPERATURE IS ABOVE 95°F (ADJ.) OR BELOW 45°F (ADJ.)
WALLMOUNTED
B.I. - OCCUPANCY OVERRIDE
A.I. - ZONE TEMPERATURE SETPOINT
THIS UNIT SHALL BE CONTROLLED BY A DEDICATED DIGITAL CONTROLLER BY JCI. THE CONTROLLERSHALL BE CONNECTED TO THE EXISTING JCI FMS SYSTEM.
M
COILHOT WATER
UNION (TYP)
P & T PORT (TYP)
HWS
STRAINER W/ BLOWDOWN VALVE AND CAP
SHUTOFF VALVE (TYP)
HWR
2-WAY CONTROL VALVE
MANUAL BALANCE VALVE, TYP.
R-1 TITUS 18"x18" 900 - 0.08 20
24"x24"
GRILLES AND DIFFUSERS SCHEDULE PANEL
SYMBOL
S-1 TITUS
MANUF.
TDCA-AA
TYPE SOUND
LOUVER
SIZE
CORE
TYPE
6"ø
INLET
DIM.
10
THROW
FEET
150
MAX.
CFM
0.10
PRESS.
DROP(IN.)
ALUMINUM
REMARKS
21 LAY-IN
N.C. MOUNTING
24"x24"S-2 TITUS LOUVER 8"ø 13250 0.09 ALUMINUM23
S-3 TITUS 350 16 0.13 24
LAY-IN
LAY-IN
LAY-IN
ALUMINUM
ALUMINUM
TDCA-AA
TDCA-AA
TDCA-AA
24"x24"
24"x24"
LOUVER
LOUVER
10"ø
1. APPLIES TO TERMINAL AIR BOXES WITH ROUND INLETS AND RECTANGULAR OUTLETS.
RECTANGULAR INSULATED DUCT
INSULATED TRANSITION
SLIP AND DRIVE CONNECTION
AIR FLOW
INSULATED FLEX. DUCT
TRIM INSIDE FLEX. DUCT AT THIS POINT
6" MIN.
REHEAT COIL, INSULATEPER SPECIFICATIONS
SECTION OF 26 GA. GALVANIZED SHEETMETAL DUCT. SAME DIAMETER AS FLEX. DUCT
FASTEN WITH SELF-TAPPINGSHEETMETAL SCREWS (MIN. 4)
INSULATED GALVANIZED SHEET METAL DUCT
NYLON TIE WRAP, TWO REQUIREDFOR EACH END OF FLEX. DUCT (TOTAL 4).INSTALL ONE TIE WRAP TO SECURE THEINNER LINER AND ONE TO SECURE THEOUTER SHELL (TYP)
TA
KE
OF
F D
IAM
ET
ER
CU
T D
UC
T O
PE
NIN
GT
O M
AT
CH
LA
RG
ER
PRE-MANUFACTERED CONICALTAKE-OFF WITH SELF-ADHESIVENEOPRENE GASKET (EQUAL TO SHEETMETAL CONNECTORS CONICAL E-Z TAP
NOTES:
R
R
ED
A
N
PE10505044
PROF I N
O
E
SSI
LAN
D I
E
NA
STATE OF
No.
EN
GI
RE
R
A
T
GAY E
NWS
TSI
.
RE
NE IH
T
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
03/14/2017
M2.1
MECHANICAL DETAILS &SCHEDULES
RWSRWS CSM
NOTES:1. THROW DATA FOR SQUARE DIFFUSERS ARE BASED ON 4-WAY THROW, TERMINAL VELOCITY AT 50 FPM.2. PROVIDE APPROPRIATE FRAME AND ALL NECESSARY ACCESSORIES FOR MOUNTING GRILLES IN A HARD CEILING, WHERE REQUIRED.3. 24"x24" LOUVERED CORE DIFFUSERS AND GRILLES W/ ROUND INLETS SHALL ALL HAVE AN 18"x18" BACKPAN SIZE.4. R-1 SHALL HAVE AN INTERNALLY LINED DUCT ELBOW BOOT DIRECTED AWAY FROM OTHER OFFICES OR CORRIDORS.5. TITUS, PRICE, ANEMOSTAT ARE ACCEPTABLE MANUFACTURERS.
M.1
M.2
M.3
M.4
M.5
M.6
M.7
M.8
M.9
DUCTWORK:
SUBSTITUTIONS SHALL BE MADE ONLY WITH APPROVAL OF ENGINEER
INDIANA PLUMBING CODEINDIANA MECHANICAL CODEINDIANA BUILDING CODE
SMACNA HVAC DUCT CONSTRUCTION STANDARDSOSHA
GENERAL:
ELBOWS SHALL BE RADIUS TYPE WITH A (1.5 X WIDTH) CENTERLINE RADIUS OR SQUARE TURNWITH SINGLE THICKNESS TURNING VANES. SEAL INTERIOR DUCTWORK PER SMACNA "HVAC DUCTCONSTRUCTION STANDARDS" 15d, SEAL CLASS "C" FOR LOW PRESSURE. DUCT ABOVE ROOFSHALL BE SEAL CLASS "B".
DUCTWORK SHALL BE GALVANIZED SHEET METAL AS REQUIRED BY SMACNA 2" PRESSURE CLASSFOR LOW PRESSURE.
MECHANICAL SPECIFICATIONS
ROUTE DUCTWORK AS SHOWN ON PLAN; FIELD VERIFY ROUTING, AND CLEARANCES.PREFABRICATE AS MUCH DUCT AS POSSIBLE. ALLOW FOR FIELD TRIM AND ADJUSTMENTS.COORDINATE ANY CONFLICTS WITH ENGINEER PRIOR TO INSTALLATION.
INTERIOR ROUND SUPPLY AIR AND ROUND RETURN AIR DUCTWORK SHALL BE EXTERNALLYWRAPPED WITH 1-1/2" THICK FIBERGLASS INSULATION.
APPLICABLE NFPA STANDARDS
ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE ANDLOCAL CODES AND REGULATIONS INCLUDING BUT NOT LIMITED TO THE FOLLOWING :
M.10 THE SYSTEM SHALL BE BALANCED BY AN INDEPENDENT AABC OR NEBB CERTIFIED BALANCINGCONTRACTOR. THE BALANCING CONTRACTOR SHALL SUBMIT THREE (3) CERTIFIED REPORTSTO THE ENGINEER.
ALL LOW VOLTAGE WIRING SHALL BE BY THE TEMPERATURE CONTROL CONTRACTOR.
COORDINATE DUCTWORK WITH LIGHT FIXTURE SUPPORTS, CONDUIT, PLUMBING, FIREPROTECTION PIPING AND OTHER TRADES.
M.11
ALL INSTALLATIONS SHALL BE SEISMICALLY SECURED.M.12
FIRESTOP ALL FIREWALL AND FLOOR PENETRATIONS.M.13
CONTRACTOR SHALL NOTIFY OWNER IN WRITING 3 DAYS IN ADVANCE FOR ALL UTILITYDISRUPTIONS. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH THE OWNER ANDENGINEER. THE PROJECT SHALL BE PHASED TO MINIMIZED THE DISRUPTION TO THE FACILITIES.
M.14
THE HVAC DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO INDICATE GENERALARRANGEMENT OF EQUIPMENT, DUCTWORK AND PIPING. CONTRACTOR SHALL MAKEMODIFICATIONS IN THE INSTALLATION SO ALL EQUIPMENT AND MATERIALS FIT PROPERLY ANDCAN BE SERVICED. COORDINATE ALL WORK WITH OTHER TRADES.
CONTRACTOR SHALL SUBMIT FOUR (4) COPIES OF EQUIPMENT AND DIFFUSER INFORMATION TO THEENGINEER. INCLUDED IN THE INFORMATION SHALL BE WIRING DIAGRAMS, MAINTENANCEINSTRUCTIONS, AND PARTS LIST.
NO SCALE
SUPPLY DIFFUSER CONNECTION DETAIL
NO SCALE
AIR TERMINAL AND HOTWATER COIL PIPING DETAIL (2-WAY)
NOTES:1. PROVIDE UNIT WITH:
• 1/2" DUAL DENSITY FIBERGLASS LINER• FACTORY INSTALLED PRESSURE INDEPENDENT DIGITAL CONTROLLER. (SEE SEQUENCE OF OPERATION FOR FURTHER REQUIREMENTS).• ACCESS PANEL• HANGERS• WATER COIL DRAIN AND VENT• CONTROL POWER DISCONNECT
2. CONTRACTOR SHALL FIELD INSULATE HOT WATER COIL CASING WITH 1-1/2" FIBERGLASS DUCT WRAP.3. PERFORMANCE BASED ON 0.75" W.G. PRESSURE AT AIR VALVE INLET.4. JCI, TRANE, AND PRICE ARE ACCEPTABLE MANUFACTURERS.
AIR TERMINAL UNIT SCHEDULE
SYMBOL TYPE
AIR VALVE COIL
UNITDOWNSTREAMSTATIC PRESS.DROP (IN. W.G.) NOTES
DESIGNCOOLINGAIRFLOW
(CFM)
MINIMUMAIRFLOW
(CFM)INTLET
SIZE
DESIGNHEATINGAIRFLOW
(CFM
ENTERINGAIR TEMP.
(°F)
LEAVINGAIR TEMP.
(°F)
ENTERINGWATER
TEMP. (°F)
LEAVINGWATER
TEMP. (°F)
FLOWRATE(GPM)
WATERPRESS.
DROP (FT.W.G.)
COILROWS
VAV-1075 SINGLE DUCTTERMINAL UNIT
450 350 8" 450 55 80 180 146 0.8 0.4 1 0.2 EXISTING
VAV-1076 SINGLE DUCTTERMINAL UNIT
320 80 6" 320 55 95 180 134 0.6 0.1 2 0.2
VAV-1077B SINGLE DUCTTERMINAL UNIT
740 190 10" 480 55 95 180 128 1.0 0.2 2 0.2
VAV-1086 SINGLE DUCTTERMINAL UNIT
240 150 6" 150 55 80 180 143 0.5 0.1 1 0.2 EXISTING
VV-1077 FAN POWERED 625 1250 62 80 180 130 1.0 0.3 1 0.2 EXISTING
VV-1079 FAN POWERED 345 690 62 95 180 126 1.2 0.6 1 0.2 EXISTING
VV-1081 FAN POWERED 220 440 62 95 180 163 1.9 0.7 1 0.2 EXISTING
VV-1082 FAN POWERED 110 210 62 95 180 144 0.7 0.1 1 0.2 EXISTING
VV-1083 FAN POWERED 110 210 62 95 180 144 0.7 0.1 1 0.2 EXISTING
VV-1084 FAN POWERED 130 260 62 95 180 144 0.7 0.1 1 0.2 EXISTING
VV-1085 FAN POWERED 160 320 62 95 180 146 0.7 0.1 1 0.2 EXISTING
1250
690
440
210
210
260
320
8"
6"
6"
6"
6"
6"
6"
NO SCALE
TERMINAL AIR BOX DETAIL
# Description Date
S
a
F1
1,3,5,...
a,b,c,...
WALL MOUNT JUNCTION BOX.
CONNECTION TO ELECTRICAL SYSTEM GROUNDING SYSTEM.
PHASECONDUCTOR
NEUTRAL
GROUND
HOMERUN TO PANEL INDICATED. NUMBER OF ARROWHEADS INDICATESNUMBER OF CIRCUITS. PREFIX INDICATES PANEL NOMENCLATURE.NUMBERS INDICATE CIRCUIT NUMBERS
L1BW-1,3,5
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
SYMBOL DESCRIPTIONDESCRIPTIONSYMBOL
WALL OUTLET WITH 20A, 125V DUPLEX RECEPTACLE. MOUNT18 INCHES ABOVE FINISHED FLOOR TO CENTER, UNLESSNOTED OTHERWISE.
WALL OUTLET WITH 20A, 125V DUPLEX RECEPTACLE. MOUNT46 INCHES ABOVE FINISHED FLOOR TO CENTER, OR 8 INCHESABOVE COUNTER OR COUNTER BACKSPLASH TO CENTER,UNLESS NOTED OTHERWISE.
WALL OUTLET WITH 20A, 125V DOUBLE-DUPLEXRECEPTACLE. MOUNT 18 INCHES ABOVE FINISHED FLOOR TOCENTER, UNLESS NOTED OTHERWISE.
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
CEILING MONT JUNCTION BOX.
NUMBER INDICATES MOUNTING HEIGHT ABOVE FINISHEDFLOOR TO BOTTOM OF OUTLET BOX WHEN SHOWN NEXT TOSYMBOL.
+42"
SYMBOL INDICATES FIXTURE TYPE WHEN SHOWN ON LIGHTINGPLANS ADJACENT TO FIXTURE SYMBOL. REFER TO LIGHTINGFIXTURE SCHEDULE FOR FIXTURE REQUIREMENTS.
CIRCUIT. NUMBER OF CROSSBARS INDICATE QUANTITY OFCONDUCTORS REQUIRED. MINIMUM CONDUIT SIZE SHALL BE3/4 INCH TRADE SIZE. MINIMUM SIZE CONDUCTORS SHALL BE12 AWG.
"GFI"
VOICE/DATA OUTLET. MOUNT OUTLET AT SAME HEIGHT AS THEASSOCIATED POWER OUTLET, UNLESS NOTED OTHERWISE. PROVIDE 1INCH CONDUIT FROM OUTLET BOX TO NEAREST ACCESSIBLE CEILINGCAVITY. BUSH CONDUIT ENDS. PROVIDE TWO DATA CABLES TO OUTLET.OUTLET BOX SHALL BE 4" SQUARE BY 2-3/4" DEEP WITH A SINGLE-GANGPLASTER RING, UNLESS NOTED OTHERWISE. SEE "TYPICAL VOICE/DATACONDUIT INSTALLATION DETAIL", "TYPICAL VOICE/DATA AND POWEROUTLET DETAIL" , AND "INFORMATION OUTLET FACEPLATECONFIGURATION", THIS SHEET, FOR ADDITIONAL REQUIREMENTS.
DESCRIPTIONSYMBOL
OUTLET BOX AND 20A, SINGLE POLE SWITCH. MOUNT AT 46 INCHESABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.LOCATE WITHIN 12" OF STRIKE SIDE OF DOOR, UNLESS NOTEDOTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT SWITCHED.
SYMBOL INDICATES GROUND FAULT INTERRUPTER TYPERECEPTACLE WHEN SHOWN PLANS ADJACENT TO SYMBOL.
NUMBERS INDICATE CIRCUIT NUMBERS WHEN SHOWN NEXTTO OR WITHIN SYMBOL ON PLANS.
WALL OUTLET WITH 20A, 125V DOUBLE-DUPLEXRECEPTACLE. MOUNT 46 INCHES ABOVE FINISHED FLOOR TOCENTER, OR 8 INCHES ABOVE COUNTER OR COUNTERBACKSPLASH TO CENTER, UNLESS NOTED OTHERWISE.
OCCUPANCY SENSOR (RATED FOR USE IN LOCATION SHOWN).
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
LOWER CASE LETTERS INDICATE SWITCHING ARRANGEMENTWHEN SHOWN NEXT TO OR WITHIN SYMBOL ON PLANS.
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
a
ELECTRICAL LEGEND - POWERELECTRICAL LEGEND - LIGHTING ELECTRICAL LEGEND - SYSTEMS & TECHNOLOGY
TELECOMMUNICATIONS
J
J
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
DESCRIPTIONSYMBOL
FIRE ALARM SYSTEM
AUDIO-VISUAL ALARM DEVICE. FIRE ALARM SYSTEM. WALLMOUNT AT 80 INCHES A.F.F. TO CENTER OF VISUAL ALARMDEVICE, OR 6 INCHES BELOW CEILING TO TOP, WHICHEVER ISLOWER.
NL SYMBOL INDICATES NIGHT LIGHTING CIRCUIT WHEN SHOWNON LIGHTING PLANS ADJECENT TO FIXTURE.
HALF-HATCHING PATTERN SHOWN WITHIN LIGHTING FIXTURE SYMBOLINDICATES LIGHTING FIXTURE CONNECTED TO EMERGENCY POWERCIRCUIT AND NIGHT LIGHTING.
WALL OUTLET WITH 20A, 125V DUPLEX AND TWO USBACCESS PORTS. MOUNT 18" ABOVE FINISHED FLOOR TOCENTER, UNLESS NOTED OTHERWISE.
DESCRIPTIONSYMBOL
1" CONDUIT ROUTEDWITHIN WALL.
FINISHED FLOOR
OUTLET BOX AS SPECIFIED AND NOTED.
ACCESSIBLECEILING CAVITY
EXTEND CONDUIT PASTCEILING AND PROVIDE A 90°BEND IN CONDUIT. BUSHCONDUIT ENDS. EXTEND TONEAREST ACCESSIBLECEILING CAVITY.
PROVIDE A 4'SERVICE LOOPAT OUTLET BOXAND WITHIN THECOMM ROOMEQUIP RACK.
OUTLET BOX.
POWER, VOICE/DATA, ANDVIDEO OUTLET BOXES SHALLBE NEATLY GROUPEDTOGETHER AT THE SAMEMOUNTING HEIGHTS.(TYPICAL, ALL LOCATIONS).
VOICE/DATA RECEPTACLE
NOTE: COORDINATE EXACT OUTLET BOX INSTALLATIONLOCATIONS IN FIELD WITH ARCHITECT PRIOR TO ROUGH-IN.
NON-ACCESSIBLECEILING CAVITYOR AREA OF EXPOSEDBLDG STRUCTURE
TO PATCHPANEL INCOMM RM
NOTE: IN AREAS WITH EXPOSEDBLDG STRUCTURE ALONG ROOMWALLS (I.E. "FLOATING CEILINGS"),EXTEND CONDUIT TO A POINT ABOVE(AND PAST THE EDGE OF THEFLOATING CEILING) THE ACCESSIBLECEILING CAVITY AS REQUIRED TOPREVENT SEEING LOW VOLTAGECABLING FROM BELOW.
4"
MAX.
DETAIL - TYPICAL VOICE, DATA & POWER OUTLET INSTALLATIONNO SCALE
DETAIL - TYPICAL VOICE, DATA, & INSTRUCTIONAL TECHNOLOGYCONDUIT & CABLE INSTALLATION (WALL BOX LOCATIONS)NO SCALE
GENERAL REQUIREMENTS FOR STRUCTUREDVOICE & DATA CABLING SYSTEMS
CEILING OUTLET AND EXIT LIGHT FIXTURE AS SCHEDULED.ARROWS INDICATE DIRECTION ARROWS REQUIRED
F
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
WIRELESS NETWORK ACCESS SYSTEM OUTLET.
S3
S4
OUTLET BOX AND 20A, THREE-WAY SWITCH. MOUNT AT 46 INCHESABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.LOCATE WITHIN 12" OF STRIKE SIDE OF DOOR, UNLESS NOTEDOTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT SWITCHED.
OUTLET BOX AND 20A, FOUR-WAY SWITCH. MOUNT AT 46 INCHESABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.LOCATE WITHIN 12" OF STRIKE SIDE OF DOOR, UNLESS NOTEDOTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT SWITCHED.
a
a
OUTLET BOX AND 20A, DIMMING SWITCH. MOUNT AT 46 INCHESABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.LOCATE WITHIN 12" OF STRIKE SIDE OF DOOR, UNLESS NOTEDOTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT SWITCHED.
a
30
28
29
27
2625
24
22
23
21
2019
18
16 20A
17
15
14 20A13
SPACE
SPACE
12 20A
10 20A
20A 11
20A 9
8 20A20A 7 VAV BOXES
6 20A
4 20A
20A 5
20A 3
2 20A20A 1 LTG, REGISTRAR
125A
RECEPTION TRACK LIGHTS
42 20A20A 41
40 20A
38 20A
20A 39
20A 37
36 20A
34 20A
20A 35
20A 33
32 20A20A 31
30 20A
28 20A
20A 29
20A 27
26 20A20A 25
24 20A
22 20A
20A 23
20A 21
20 20A20A 19
18 20A
16 20A
20A 17
20A 15
14 20A20A 13
12 20A
10 20A
20A 11
20A 9
8 20A20A 7
6 20A
4 20A
20A 5
20A 3
2 20A20A 1
100A
225A, 480Y/277V, 3PH, 4WSURFACE MOUNT42 SPACE18,000 A.I.C.PROVIDE WITH HINGED COVER ENCLOSURE*PROVIDE A TYPED INDEX CARD
EXISTING PANEL "H1W"225A, 208Y/120V, 3PH, 4WSURFACE MOUNT42 SPACE10,000 A.I.C.*PROVIDE A TYPED INDEX CARD
EXISTING PANEL "L1BW"
42 20A20A 41
40 20A
38 20A
20A 39
20A 37
36 20A
34 20A
20A 35
20A 33
32 20A20A 31
SPACE30 20A
28 20A
20A 29
20A 27
26 20A20A 25
24 20A
22 20A
20A 23
20A 21
20 20A20A 19
RECEPTS, 1108, 1109, 1112
18 20A
16 20A
20A 17
20A 15
14 20A20A 13
12 20A
10 20A
20A 11
20A 9
8 20A20A 7 RECEPTS, 1091, CORRIDOR
6 20A
4 20A
20A 5
20A 3
2 20A20A 1 T/P POLES 1108
100A
SPACE
RECEPTS, 1108, 1109, 1112
RECEPTS, 1108
225A, 208Y/120V, 3PH, 4WSURFACE MOUNT42 SPACE10,000 A.I.C.*PANEL IS FOR REFERENCE ONLY
EXISTING PANEL "L1AW"
T/P POLES 1108
T/P POLES (FUTURE)1108
RECEPTS, 1110, 1111
T/P POLES (FUTURE), 1110
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTACLES
RECEPTS, 1092, 1111
RECEPTS, 1074, 1093
RECEPTS, 1094, 1110
RECEPTS, 1095, CORRIDOR
RECEPTS, 1096, 1110
RECEPTS, 1108
RECEPTS, 1089
EXISTING LOAD
EXISTING LOAD
LTG, RMS 1096, CORRIDOR
LTG, RM 1070, MICROWAVE
RECEPTS, RMS 1076, 1076-1
RECEPTS, RM 1085
RECEPT, RM 1086-1(COFFEE MAKER)
RECEPTS, RM 1086-2
RECEPTS, RMS 1071, 1072, CORRIDOR
RECEPTS, RM 1075
TEMP CONTROL PANEL, RM 1112
MAINTENANCE
RECEPTS, RMS 1072, 1070
RECEPTS, RM 1076-2
RECEPTS, RM 1077
RECEPTS, RM 1081
RECEPTS, RM 1082
RECEPTS, RM 1076(SYSTEM FURNITURE)
WEST CORRIDOR, AOA
SPACE
RECEPTS, RM 1084
RECEPT, RM 1086-2(COPIER,FAX,PRINTER)
RECEPTS, RM 1083
SPARE
SPARE
SPARE
SPARE
VAV BOXES HONORS AREA
LTG, REGISTRAR
LTG, 1060,1061,1060A,1064,1065,1071,1071A,1072,1070LTG, 1096-1099 & 1103-1107
LTG, CORRIDOR
41
39
37
36
34
35
33
3231
90ATRANSFORMER "XF1W"
LTG, 1091-1095 & 1111
LTG, 1108, 1099 & 1112
VAV BOXES HONORS AREA
RECEPTACLES
STAIR GATE HOLD
RECEPTS, RM 1076(SYSTEM FURNITURE)
RECEPTS, RM 1076(SYSTEM FURNITURE)
RECEPTS, RM 1072
RECEPTS, RMS 1079, 1080
RECEPT, RM 1086-1(REFRIGERATOR)
RECEPT, RM 1086-1(MICROWAVE)
RECEPTS, RM 1086-1
NOTE 1
NOTE 2
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTE 1 NOTE 1
NOTE 1
RECEPTS, RM 1078
RECEPTS, RM 1076-2
RECEPTS, RM 1076
CONDUIT RACEWAY
FINISHED CEILING
SUPPORT CONDUIT VIAADJUSTABLE BAR TYPEHANGER DEVICES ORDIRECTLY TO METALSTUDS USING CONDUIT STRAPS.
OUTLET BOX SECUREDTO METAL STUDSUSINGSIDE MOUNT DEVICE.
PROVIDE WITHMETALLICGYPBOARD STANDOFFSUPPORT AS REQUIREDTO KEEP OUTLET BOXFROM MOVING IN & OUT.
METAL STUD.CONDUIT RACEWAY
FINISHED CEILING
SUPPORT CONDUIT VIAADJUSTABLE BAR TYPEHANGER DEVICES ORDIRECTLY TO METALSTUDS USING CONDUIT STRAPS.
OUTLET BOX.SUPPORTOUTLET BOX TO METALSTUDS USINGADJUSTABLE BAR TYPEHANGER DEVICE. ADJUSTABLE
BARHANGER
METAL STUD
DETAIL - TYPICAL OUTLET BOX SUPPORT DETAIL #1NO SCALE
DETAIL - TYPICAL OUTLET BOX SUPPORT DETAIL#2 (TO BE USED WHEN INSTALLATION AS SHOWN INOUTLET BOX SUPPORT DETAIL #1 IS NOT POSSIBLE)NO SCALE
A
M
R
ED
N
D
STATE OF
PE60900441
OF I
SS
E
OI
N
R
M
P
E
NLA
I A
E
N A N
GI
ER
AN
W
T
HT EGE
. BEIST
J
R
R CKO
NO.
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
03/14/2017
E1.1
ELECTRICAL LEGEND ANDBUSSING DIAGRAM
CWWCWW CWW
BUSSING DIAGRAM
BUSSING NOTES:1. UTILIZE EXISTING CIRCUIT BREAKER MADE SPARE BY DEMOLITION.
2. UTILIZE EXISTING SPARE CIRCUIT BREAKER.
# Description Date
J J J
JJ J
J
JTV
J
F
F
F
F
F
F
F
J
JJ
J
J
J
J
J
S
SS S S
S
S
S
S
SS
S
J
S
SS
SS
S
OFFICE1085
BREAK1086-1
STORAGE1086-2
WAITING1075
CORR1076-1
OPEN OFFICE1076
CORR1076-2
OFFICE1084
OFFICE1083
OFFICE1082
OFFICE1081
OFFICE1080
OFFICE1079
OFFICE1078
CONFERENCE1077
GFI GFI GFI
NOTE 7 NOTE 8 NOTE 9
L1BW-13L1BW-15 L1BW-11EX
EXEX
EX
EX
EX
EX
NOTES 4 & 5 NOTES 4 & 5NOTES 4 & 5
NOTE 6
NOTE 11
NOTE 10
EX
L1BW-34
L1BW-32
L1BW-27
L1BW-30
L1BW-37
L1BW-28L1BW-26L1BW-24
L1BW-40
L1BW-25
L1BW-36L1BW-17
EX
EX
EX
L1BW-5
L1BW-39
L1BW-33
L1BW-31
EX
NOTE 12
EX
L1BW-21
L1BW-19
NOTE 12
NOTE 13,TYPICAL OF 6
NOTE 10
24 24 24 24 26 2826 26 26 28 28 28a
aabbccbc
NOTE 1
NOTE 2
NOTE 1
NOTE 1
NOTE 3
NOTE 3NOTE 3
NOTE 3
NOTE 3
GENERAL DEMOLITION NOTES FORENTIRE PROJECT:D1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE BUILDINGAND SITE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. THESEREMOVAL DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN HISEVALUATION OF THE EXTENT OF REMOVALS, BUT SHALL NOT BE HELD TO BEALL INCLUSIVE.
D2. FOR FURTHER INFORMATION WITH REGARD TO EXTENT OF REMOVALS,SEE THE CONSTRUCTION PLANS WHICH ILLUSTRATE THE ADJACENT NEWCONSTRUCTION.
D3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVALSREQUIRED FOR THE INSTALLATION OF NEW WORK, WHETHER OR NOT IT ISSPECIFICALLY INDICATED OR NOTED IN THESE DOCUMENTS.
D4. ALL EQUIPMENT REMOVED FOR RELOCATION SHALL BE REMOVED INSUCH A MANNER THAT REUSE IS POSSIBLE.
D5. ALL CONDUIT RUNS TO REMOVED EQUIPMENT SHALL HAVE ALLCONDUCTORS REMOVED, UNLESS CONDUCTORS ARE REQUIRED TO SERVEEXISTING EQUIPMENT TO REMAIN.
D6. REMOVAL OF EMPTY CONDUIT SHALL BE REQUIRED ONLY IF SUCHCONDUIT INTERFERES WITH THE NEW CONSTRUCTION AND/OR IF INDICATEDTO BE DISCONNECT AND REMOVED COMPLETE BACK TO SOURCE OF FEED.
D7. IF PORTIONS OF CIRCUITS SERVING EQUIPMENT TO REMAIN MUST BERELOCATED OR REMOVED DUE TO OTHER DEMOLITION OR DUE TOINTERFERENCE WITH NEW EQUIPMENT INSTALLATION, THE CIRCUITS SHALLBE MODIFIED IN A MANNER WHICH SHALL ENSURE PROPER OPERATION OFTHE EQUIPMENT AFTER THE CONSTRUCTION IS COMPLETE. CONTRACTORSHALL USE THE SAME GAUGE AND TYPE OF CONDUCTOR, AND THE SAMECONDUIT SIZE AS EXISTING TO MAKE ALL REQUIRED CIRCUIT MODIFICATIONS.
D8. IF WALLS, CEILINGS, FLOORS, OR EQUIPMENT ARE REMOVED, OROTHER DEMOLITION OCCURS, WHICH EXPOSES CIRCUITS SERVINGEQUIPMENT TO REMAIN, THE CIRCUITS SHALL BE RELOCATED OR MODIFIEDIN SUCH A MANNER WHICH SHALL ENSURE THE CONTINUED OPERATION OFTHE CIRCUIT. EXISTING CONDUITS EXPOSED DURING DEMOLITION WHICHREMAIN TO SERVE EQUIPMENT SHALL BE RESUPPORTED IN ACCORDANCEWITH THE REQUIREMENTS OF THE NEC.
D9. EQUIPMENT REMOVED FOR RELOCATION BUT NOT RELOCATED SHALLBE STORED AT A LOCATION DIRECTED BY THE OWNER.
D10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPERDISPOSAL OF ALL EQUIPMENT REMOVED.
D11. OWNER RESERVES THE FIRST RIGHT OF REFUSAL OF REMOVEDEQUIPMENT.
D12. THE CONTRACTOR SHALL COORDINATE DISRUPTION OF SERVICESWITH THE OWNER. DISRUPTIONS OF SERVICES SHALL BE KEPT TO AMINIMUM. DISRUPTIONS SHALL ONLY OCCUR AFTER RECEIVING OWNERPRIOR APPROVAL.
D13. THE CONTRACTOR SHALL REFER TO THE MECHANICAL, PLUMBING,AND ARCHITECTURAL PLANS FOR ADDITIONAL REQUIREMENTS ONEQUIPMENT AND AREAS REQUIRING REMOVALS.
ELEC1089 EXISTING PANEL "L1BW"
EXISTING PANEL "L1AW"
EXISTING PANEL "H1W"
1059COMMUNICATIONS
APPROXIMATE BASEMENTLOCATION OF EXISTINGPANEL "EHB"
1/4" = 1'-0"FIRST FLOOR POWER AND SYSTEMS PLAN
A
M
R
ED
N
D
STATE OF
PE60900441
OF I
SS
E
OI
N
R
M
P
E
NLA
I A
E
N A N
GI
ER
AN
W
T
HT EGE
. BEIST
J
R
R CKO
NO.
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
03/14/2017
E2.1
FIRST FLOOR ELECTRICALDEMOLITION, POWER AND
SYSTEMS PLAN
CWWCWW CWW
1/4" = 1'-0"FIRST FLOOR ELECTRICAL DEMOLITION PLAN
2'0' 4' 8'
North
2'0' 4' 8'
North
NOTES:1. UNLESS NOTED OTHERWISE, DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES, FIREALARM DEVICES, COMMUNICATION DEVICES, DATA DEVICES, AND LIGHTING AND ASSOCIATEDDEVICES WITHIN THIS AREA AS REQUIRED FOR DEMOLITION AND NEW CONSTRUCTION.
2. DISCONNECT AND REMOVE ALL LIGHTING FIXTURES AND ASSOCIATED DEVICES WITHIN THISAREA. BRANCH CIRCUITS SHALL REMAIN FOR REUSE.
3. DATA OUTLET TO REMAIN. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR ANDMATERIAL TO PROTECT CABLE AND OUTLET DURING DEMOLITION AND REWORK OUTLET ASNEEDED FOR NEW CONSTRUCTION. DATA OUTLET SHALL WORK AS BEFORE DEMOLITION.
4. JUNCTION BOX FOR POWER CONNECTION TO SYSTEM FURNITURE. COORDINATE WITHFURNITURE PROVIDER AND OWNER FOR EXACT LOCATION AND MOUNTING HEIGHT PRIOR TOROUGH-IN. PROVIDE FINAL CONNECTIONS PER MANUFACTURER'S REQUIREMENTS.
5. PROVIDE A LOW VOLTAGE RING FOR LOW VOLTAGE CABLE TO SYSTEM FURNITURE. PROVIDEA 2" CONDUIT FROM THE TOP OF THE LOW VOLTAGE RING TO ACCESSIBLE CEILING AND BUSHCONDUT ENDS. COORDINATE WITH FURNITURE PROVIDER AND OWNER FOR EXACT LOCATIONAND MOUNTING HEIGHT PRIOR TO ROUGH-IN. PROVIDE FINAL CONNECTIONS PERMANUFACTURER'S REQUIREMENTS.
6. DEDICATED BRANCH CIRCUIT AND RECEPTACLE FOR COPIER/FAX/PRINTER MACHINE.
7. DEDICATED BRANCH CIRCUIT AND RECEPTACLE FOR MICROWAVE.
8. DEDICATED BRANCH CIRCUIT AND RECEPTACLE FOR COFFEE MAKER.
9. DEDICATED BRANCH CIRCUIT AND RECEPTACLE FOR REFRIGERATOR.
10. PROVIDE LOW VOLTAGE RING FOR LOW VOLTAGE CABLE OUTLET FOR OWNER FURNISHEDAND INSTALLED HDMI CABLE. PROVIDE A QUANTITY OF ONE 1-1/2" CONDUIT FROM THE TOP OFTHE LOW VOLTAGE RING TO ACCESSIBLE CEILING AND BUSH CONDUIT ENDS. PROVIDE A PULLSTRING IN CONDUIT. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH OWNER PRIORTO ROUGH-IN. PROVIDE A SINGLE GANG MOUNTING PLATE WITH STAINLESS STEEL LOWVOLTAGE CABLE ACCESS RING.
11. CONFERNECE TELEVISION LOCATION. PROVIDE ONE RECEPTACLE OUTLET FOR POWER,ONE OUTLET FOR COAX CABLE, ONE OUTLET FOR DATA, AND ONE JUNCTION BOX FOR HDMIOUTLET. MOUNT BANK OF OUTLETS AT 84" ABOVE FINISHED FLOOR TO CENTER.
12. COORDINATE WITH ARCHITECT AND OWNER FOR EXACT INSTALLATION LOCATION ANDMOUNTING HEIGHT PRIOR TO ROUGH-IN.
13. RECEPTACLE AND DATA OUTLET LOCATIONS BUILT INTO BOTTOM OF SYSTEM FURNITURE.REFER TO MANUFACTURER FOR ADDITIONAL REQUIREMENTS.
1/16" = 1'-0"ELECTRICAL AND COMMUNICATION ROOM LOCATIONS
4'0' 8' 16'
North
GENERAL POWER AND SYSTEMS NOTESFOR ENTIRE PROJECT:A. SEE PROJECT SPECIFICATIONS, DIVISION 27, SECTION 271310, FOR ADDITIONALREQUIREMENTS REGARDING QUANTITY AND TYPES OF CABLES ROUTED TO WORK AREAOUTLETS.
B. ALL RECEPTACLES AND SWITCHES IN PROJECT WORK AREA SHALL BE IVORY IN COLOR WITHSTAINLESS STEEL COVER PLATES.
# Description Date
S
S
S
S
S
S
S
S
S
S
S
S
S
F5F
F3
F3 F3
F3F3
F3
F1F1F1
F1
F1F2
F1
F1
F1 F1
F2
F2
F1F1
F1 F1F1 F1
F1F1F1F1
F1
F1
F1
F1
F1
F1
F1F1F1F1F1
F3
F2
F4F4F4F4F4 F4
3a
3a
4a
3b
3b
cd
e
e e
c
d d d
b
a
a
aa
a a
b b b b
f
f
f
3
3 3
3
OPEN OFFICE1076
CORR1076-1
STORAGE1086-2
WAITING1075
BREAK1086-1
OFFICE1085
OFFICE1084
OFFICE1083
OFFICE1082
OFFICE1081
WORK1076-3
CORR1076-2
OFFICE1080
OFFICE1079
OFFICE1078
CONFERENCE1077
3f
H1W-2
H1W-4
3
3
g
g g g gg g
NL
NL
NL
NL NL
NLNLNL
NL
F5A F5AF5CF5AF5DF5A
F5
F3 F3
F3
EX1R
EX1
EX1L
EX1
F5E
F5
F5EF5F5E
F5
F5Ef
f
fff
f
ff
NOTE 1. TYPICAL, ALL NIGHTAND EXIT LIGHTING FIXTURES
NOTE 2
NOTE 2
NOTE 2
NOTE 2 NOTE 2 NOTE 2 NOTE 2
NOTE 2
NOTE 2
NOTE 2
NL
EX1
F3
F4
F5
F5A
F1
RECESSED --- ---120/277(MULTI-VOLT)
6" DIAMETER APERTURE, MEDIUMDISTRIBUTION OPEN DOWNLIGHT,RECESSED DOWNLIGHT, WITH A MAXIMUMFIXTURE DEPTH OF 8". NOMINAL 2000LUMENS OUTPUT. DIMMABLE USING 0 TO10V DIMMING CONTROLS. ACCESSIBLEFROM BELOW A HARD CEILING.
PATHWAY 6VLED2000 SERIES
LEDS 4000K(50,000 HRSWITH 70%
LUMENMAINTENANCE)
QNTYAS
REQUIRED
25W(FIXTURE
INPUTWATTS)
LITHONIA
RECESSED --- ---2'x4' LED RECESSED INDIRECT FIXTUREWITH SOFT INDIRECT LIGHTING. NOMINAL4000 LUMENS OUTPUT, DIMMABLE USING 0TO 10V DIMMING CONTROLS. LIGHT FIXTUREHAS A MAXIMUM DEPTH OF 5".
120/277(MULTI-VOLT)
OM6LED-2000 SERIESPHILIPS OMEGA LTG
2BZL SERIES LEDS 4000K(60,000 HRSWITH 90%
LUMENMAINTENANCE)
QNTYAS
REQUIRED39W ---
---
COOPER __ SERIES
PORTFOLIO LD620D010-ERM SERIES
MANUFACTURER SYMBOL DESCRIPTIONLOUVER FINISH
LIGHTING FIXTURE SCHEDULE
TYPEFIXTURE SERIES
LAMP
LENS WATTS REFLECTOR MOUNTINGBALLAST
LIGHT CONTROLREMARKSFIXTURE
VOLTAGEQNTY PERFIXTURE
FOCAL POINT SKYDOME24" DIAMETER LED FIXTURE MADE WITHEXTRUDED ALUMINUM. 2000 LUMENSOUTPUT, DIMMABLE USING 0 TO 10VDIMMING CONTROLS. ACCESSIBLE FROMBELOW A HARD CEILING.
SAME AS FIXTURE "F5", 4' LENGTH.
2' LENGTH WITH 2" WIDTH RECESSED LEDGEOMETRIC LIGHTING FIXTURE SYSTEM CAPABLEOF MULTIPLE DESIGNS WITH ILLUMINATEDCORNERS AND HAIRLINE JOINTS AND A MAXIMUMDEPTH OF 5.5". 400 LUMEN/FOOT OUTPUT,DIMMABLE USING 0 TO 10V DIMMING CONTROLS.
LEDS 4000K(100,000 HRS
WITH 90%LUMEN
MAINTENANCE)
LEDS 4000K(50,000 HRSWITH 70%
LUMENMAINTENANCE)
QNTYAS
REQUIRED
QNTYAS
REQUIRED
43W
4.4W/FT.
120/277(MULTI-VOLT)
120/277(MULTI-VOLT)
AXIS LIGHTING SCULPT RECESSED
LITHONIA LDN6 SERIES
NOTE 1
LIGHTING FIXTURE NOTES:1. PROVIDE FIXTURE WITH SLIDE-TO-OFF TYPE, O-TO-10V DIMMING CONTROLLER(S) [QUANTITY ASINDICATED ON THE LIGHTING PLAN]. FULLY COMPATIBLE WITH THE FIXTURE AND RATED FOROPERATION WITH THE FIXTURE AND CONNECTED LOAD. FINISH COLOR OF THE DIMMINGCONTROLLERS AND DEVICE PLATES SHALL MATCH THE COLOR OF ALL OTHER WIRINGDEVICES/DEVICE PLATES CONNECTED TO THE ASSOCIATED POWER SOURCE.
2. FIXTURE FINISH SHALL BE SELECTED DURING SHOP DRAWING SUBMITTAL /REVIEW PROCESS.
3. COORDINATE LETTER COLOR REQUIREMENTS WITH THE OWNER'S STANDARDS FOR EXITLIGHTING FIXTURES.
4. PROVIDE FIXTURE WITH DIRECTION ARROWS WHERE INDICATED ON LIGHTING PLANS.
NOTE 1
NOTES 1 & 2
NOTE 1RECESSED
SURFACEMOUNT
MARK LIGHTING SLOT 2 LED
F2
LEDS 4000K(60,000 HRSWITH 90%
LUMENMAINTENANCE)
QNTYAS
REQUIRED30W
120/277(MULTI-VOLT)
NOTE 1RECESSED
LITHONIA2'x2' LED RECESSED INDIRECT FIXTUREWITH SOFT INDIRECT LIGHTING. NOMINAL3000 LUMENS OUTPUT, DIMMABLE USING 0TO 10V DIMMING CONTROLS. LIGHTFIXTURE HAS A MAXIMUM DEPTH OF 5".
2BZL SERIES
COOPER __ SERIES
F5C SAME AS FIXTURE "F5", 10' LENGTH.
F5D SAME AS FIXTURE "F5", 14' LENGTH.
F5E SAME AS FIXTURE "F5", 2' X 2' CORNER DESIGN.
EX1 LED (RED)
LITHONIA
SURE-LITES LPX SERIES
MCPHILBEN CXX SERIES ------ ------ASREQ'D
QUANTUM SERIES
CEILING
LED (RED) ------ ------CEILING
------LED (RED) ------CEILINGEX1R
EX1L
120/277(MULTI-VOLT)
120/277(MULTI-VOLT)
120/277(MULTI-VOLT)
LITHONIA
SURE-LITES LPX SERIES
MCPHILBEN CXX SERIES
QUANTUM SERIES
LITHONIA
SURE-LITES LPX SERIES
MCPHILBEN CXX SERIES
QUANTUM SERIES
EXIT LIGHTING FIXTURE, SINGLE-FACE,WHITE THERMOPLASTIC HOUSING WITHGREEN LETTERS.
ASREQ'D
ASREQ'D
ASREQ'D
ASREQ'D
ASREQ'D
EXIT LIGHTING FIXTURE, SINGLE-FACE, WHITE THERMOPLASTICHOUSING WITH GREEN LETTERS,LEFT DIRECTION ARROW.
EXIT LIGHTING FIXTURE, SINGLE-FACE, WHITE THERMOPLASTICHOUSING WITH GREEN LETTERS,RIGHT DIRECTION ARROW.
NOTE 3
NOTES 3 & 4
NOTES 3 & 4
F5F SAME AS FIXTURE "F5", 8' X 14' CORNER DESIGN.
SATIN ACRYLICLENS
ALUMINUMREFLECTOR
ALUMINUMREFLECTOR------ ---
Red
Wht
Wht
Blk/Orn Blue
Blue
Relay (if req'd)
Normally Closed
Photocell (if req'd)
CommonNormally Open
Auto Dimming Ctrl (if req'd)
7-Brn8-Vio
6-Gry5-Blu
4-Vio w/Wht stripe
3-Blk2-Wht1-Red
SWITCH "a"N
SWITCH "b"
PowerPack
AdditionalOccupancy
Sensor(qty. as
shown onLightingPlans)
3-WAYSWITCH
3-WAYSWITCH
4-WAYSWITCH
UNSWITCHED HOT CONDUCTOR.
SWITCHED HOT CONDUCTOR.
OccupancySensor
TYPICAL MULTI-CONTROL LIGHTING CONTROL DIAGRAMNO SCALE
7-Brn8-Vio
6-Gry5-Blu
4-Vio w/Wht stripe
3-Blk2-Wht1-Red
Blk
Relay (if req'd)Relay (if req'd)
Relay (if req'd)
Normally Closed
Photocell (if req'd)
CommonNormally Open
Auto Dimming Ctrl (if req'd)
Relay (if req'd)Relay (if req'd)
Red Wht Blk
UNSWITCHED HOT CONDUCTOR.
N
Blk/Orn
Wht
PowerPack
Blue
BlueSWITCH "a"
SWITCH "b"
3-WAYSWITCH
4-WAYSWITCH
3-WAYSWITCH
SWITCHED HOT CONDUCTOR.
GENERAL LIGHTINGCONTROL NOTES:A. CONTROL DIAGRAM IS BASED ON ANOCCUPANCY SENSOR BY SENSOR SWITCHAND IS FOR THE PURPOSE OF INDICATING THEDESIRED TYPICAL OPERATION IN SPACES WITHONE OR MORE SWITCHES AND ONE OR MOREOCCUPANCY SENSORS. CONTRACTOR SHALLBE RESPONSIBLE FOR ANY DESIGN CHANGESREQUIRED TO USE PRODUCTS BY ANOTHERMANUFACTURER.
B. IT IS NOT THE INTENT OF THIS DRAWINGTO SHOW, NOR DOES THIS DRAWING SHOWEVERY CONFIGURATION OF LIGHTINGCONTROL DIAGRAM REQUIRED. THECONTRACTOR SHALL BE RESPONSIBLE FORWIRING ALL LIGHTING CONTROL PER THELIGHTING CONTROL SYSTEMMANUFACTURER'S REQUIREMENTS.
C. OPERATION: OCCUPANCY SENSOR(S)SHALL ALLOW LIGHTING WITHIN THE SPACE TOBE TURNED ON [VIA THE LIGHTING CONTROLSWITCH(S)] WHENEVER OCCUPANCY ISDETECTED. THE LIGHTING SHALL REMAIN "ON"UNTIL THE AREA HAS BEEN UNOCCUPIED FORA PERIOD OF 10 MINUTES, (UNLESS NOTEDOTHERWISE), OR THE CONTROL SWITCH ISTURNED "OFF".
D. SWITCH CONFIGURATIONS SHOWN AREFOR WIRING REFERENCE ONLY. THE SWITCHCONFIGURATION FOR A PARTICULAR SPACEMAY BE A COMBINATION OF THE ABOVE TYPESOF SWITCHING ARRANGEMENTS. THESWITCHING REQUIRED FOR EACH SPACESHALL BE AS INDICATED AND DESCRIBED FOREACH SPACE ON THE LIGHTING PLANS.
DIMMER "c"
1/4" = 1'-0"FIRST FLOOR LIGHTING PLAN
A
M
R
ED
N
D
STATE OF
PE60900441
OF I
SS
E
OI
N
R
M
P
E
NLA
I A
E
N A N
GI
ER
AN
W
T
HT EGE
. BEIST
J
R
R CKO
NO.
Drawing No:
Architect's Project No: Date:
Sheet title:
Revisions:
The drawings, specifications and other documents, including those in electronicform prepared by Hafer for this project are instruments of Service, and may beused solely with respect to this project. The documents may not be reproducedor modified by a third party without first obtaining the express written consent ofHafer. Authorized use of electronic media or file does not guarantee that thesefiles contain complete and accurate information. In order to insure the accuracyof the information contained and that no changes or modifications have beenmade, these files must be compared to the project's contract documents withstamped and sealed certification and applicable approved modifications.
In association with:
Orr Center:
Registrar Renovation
8600 University BoulevardEvansville, Indiana
Designed By: Drawn By: Checked By:
March, 20171701-109
03/14/2017
E3.1
FIRST FLOOR LIGHTING PLAN
CWWCWW CWW
2'0' 4' 8'
North
1. PROVIDE ALL LABOR AND MATERIAL TO CONNECT NIGHT LIGHTING AND EXIT SIGNSTO PANEL "EHB", CIRCUIT 13. PANEL "EHB" IS LOCATED IN THE BASEMENT MECHANICALROOM 003.
2. PROVIDE OCCUPANCY SENSOR WITH SENSING PATTERN AS REQUIRED TO COVERAREA WITHIN ROOM. LOCATE AND AIM OCCUPANCY SENSOR AS REQUIRED TO DETECTOCCUPANCY WITHIN ROOM BUT NOT TRIGGER "OCCUPANCY" FROM PERSON MOVING INCORRIDOR (OR SPACE) JUST OUTSIDE THE COMMON WALL.
NOTES:
# Description Date