2
24 Hole ‘B’ for timber frame Hole ‘A’ for metal frame Part No. ES3100/ES310 - 121 - 0515 Solenoid Plunger Solenoid Leads Strike Body Locking Pins (Long - Short - Short) Pin Chamber Fig.1 (Fail Secure) Locking Pins (Short - Short - Long) Solenoid Plunger Solenoid Leads Strike Body Pin Chamber Fig.2 (Fail Safe) To change the electric strike’s mode of lock operation, remove the back cover and the two screws securing the solenoid. Remove solenoid from strike housing, and invert the strike. This will release three locking pins from the strike and keeper chambers. Re-insert the pins as shown in the diagrams for desired mode of lock operation (Fail Secure/PTO: See Fig 1; (Fail Safe/PTL: See Fig 2). Place solenoid back in strike housing, and secure with solenoid screws. Press strike back cover into position. CAUTION! When removing solenoid, please be mindful to keep the plunger in the solenoid as it is not secured, and may be easily misplaced. Peel backing off adhesive template and centrally locate in the marked position, lining up both the mark for the door latch front face (Line 1) and the centre mark of the latch (Line 2). For the metal door drill two Ø5mm holes (A) 22mm above and below the “X” mark on the template, f or a timber door drill two Ø3mm holes (B). Ensure secondary bolt is not within the strike cavity. Using the template as a guide, mortice out the door frame to the required size. Countersink holes in metal frame to accept screws. For wider framed doors, an Extension Lip may be required. Mark centre of Door latch on frame (Line 2). Door Latch Door Frame Frame To enable the Electric strike to be located in the door frame, first mark the position of the Door Latch front face on the door frame with the door in the closed position, (”X”mm). Mark where centre of latch meets door frame: - For new installations, mark frame where front of latch touches the door frame at the midpoint of the latch bolt. - For retrofit installations, remove existing strike plate and ensure the latch fits into and is centred in existing hole. ES3100 ES310 SERIES ELECTRIC STRIKE INSTALLATION INSTRUCTIONS Mark centre of Door latch on frame (Line 2). POSITIONING OF STRIKE MARKING OF STRIKE POSITION MORTICING REBATE CHANGING MODE OF LOCK OPERATION
Transcript
Page 1: ES3100 ES310 SERIES ELECTRIC STRIKE - Lockweb Downloads... · 2019-02-22 · ES3100 ES310 SERIES ELECTRIC STRIKE INSTALLATION INSTRUCTIONS Mark centre of Door latch on frame (Line

24

Hole ‘B’ for timber frame

Hole ‘A’ for metal frame

Part

No.

ES3

100/

ES31

0 - 1

21 -

0515

Solenoid

Plunger

Solenoid Leads

Strike Body

Locking Pins(Long - Short - Short)Pin Chamber

Fig.1 (Fail Secure)

Locking Pins(Short - Short - Long)

Solenoid

Plunger

Solenoid Leads

Strike Body

Pin Chamber

Fig.2 (Fail Safe)

To change the electric strike’s mode of lock operation, remove the back cover and the two screws securing the solenoid.Remove solenoid from strike housing, and invert the strike. This will release three locking pins from the strike and keeper chambers.

Re-insert the pins as shown in the diagrams for desired mode of lock operation (Fail Secure/PTO: See Fig 1; (Fail Safe/PTL: See Fig 2).Place solenoid back in strike housing, and secure with solenoid screws. Press strike back cover into position.

CAUTION! When removing solenoid, please be mindful to keep the plunger in the solenoid as it is not secured, and may be easily misplaced.

• Peel backing off adhesive template and centrally locate in the marked position, lining up both the mark for the door latch front face (Line 1) and the centre mark of the latch (Line 2).• For the metal door drill two Ø5mm holes (A) 22mm above and below the “X” mark on the template, f or a timber door drill two Ø3mm holes (B).• Ensure secondary bolt is not within the strike cavity.

• Using the template as a guide, mortice out the door frame to the required size.• Countersink holes in metal frame to accept screws.• For wider framed doors, an Extension Lip may be required.

Mark centre of Doorlatch on frame(Line 2).

DoorLatch

DoorFrame

Frame

• To enable the Electric strike to be located in the door frame, first mark the position of the Door Latch front face on the door frame with the door in the closed position, (”X”mm).• Mark where centre of latch meets door frame: - For new installations, mark frame where front of latch touches the door frame at the midpoint of the latch bolt. - For retrofit installations, remove existing strike plate and ensure the latch fits into and is centred in existing hole.

ES3100 ES310 SERIES ELECTRIC STRIKEINSTALLATION INSTRUCTIONS

Mark centre of Doorlatch on frame(Line 2).

POSITIONING OF STRIKEMARKING OF STRIKE POSITION

MORTICING REBATE CHANGING MODE OF LOCK OPERATION

P/n

Page 2: ES3100 ES310 SERIES ELECTRIC STRIKE - Lockweb Downloads... · 2019-02-22 · ES3100 ES310 SERIES ELECTRIC STRIKE INSTALLATION INSTRUCTIONS Mark centre of Door latch on frame (Line

CAUTION! Incorrect supply voltage may cause damage not covered by warranty.

Please check supply voltage with a suitable meter to ensure it is within 10-13.8V DC.

Current required is 250mA @ 12V DC

DO NOT OIL OR LUBRICATE.

(10-13.8V DC)250mA

Fig. 3 - Electrical Schematic

Red

Power (+)

Ground (-)

The installation of a Latch guard is recommended on outward openingexternal doors.

ASSA ABLOY Australia Pty Limited, 235 Huntingdale Rd, Oakleigh, VIC 3166 ABN 90 086 451 907 ©2015An ASSA ABLOY Group brand

• For metal door frames, fit door mounting brackets.• Once door frame preparation is complete, temporarily fit strike into door frame to check for interference. Check that the door closes smoothly and that the latch extends fully past the strike keeper.• When strike operates correctly with latch, remove strike from mortice and connect wiring.

Door mounting bracket

• Refit strike and secure, making sure no wires are being crushed.• Check both mechanical and electronic operation works correctly.

TUBULAR LATCH OPERATIONTo ensure deadlatching, ensurethat the deadlatching pin isdepresed by the edge of thekeeper when the door is closed.

Keeper edge

Deadlatchingpin

ASSEMBLING STRIKE

ELECTRICAL SPECIFICATION

CHECKING FUNCTION

Metal Door FrameTimber Door Frame


Recommended