EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley
Transcript
Page 1: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

EVOLUTION OF THE ION CHAMBER

HPIC MeetingSeptember 25, 2012

Presented by Jim Shiley

Page 2: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Some of the oldest and most widely used types of radiation detectors are based on the effects produced when a charged particle passes through a gas.

Ion chamber instruments are, in principle, the simplest and therefore most reliable of these detectors.

BACKGROUND

Page 3: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

As a fast, charged particle passes through a gas, it interacts with neutral molecules resulting in an ion pair (positive ion and free electron).

This can occur by direct or indirect interaction.

The number of these interactions is a remarkably constant parameter given the gas and type of radiation.

In the presence of an electric field, the ion pairs will migrate or drift.

This drift of ion pairs creates an electric current, which can be measured.

HOW AN ION CHAMBER WORKS(OVER) SIMPLIFIED VERSION

Page 4: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

The ion chamber is the standard workhorse of portable ion chamber survey instrumentation. Used to determine dose rates and thereby

stay times Essential to ensuring safe work

environments.Eberline Services has been working to

redesign this instrument, keeping the full functionality and familiar look and feel while making the unit safer and more user friendly.

ION CHAMBER EVOLUTION

Page 5: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Assume that the ion chamber instrumentation can be updated and improved

Get input from users; ESI has a large internal pool of users in our own RCTs and IHTs

Insert new electronics and improve data processingReduce weightMove beyond survey usageEnhance data collection Use ESI background in field applications and other

developments, e.g. field surveys, GPERS, etc.

CAN MATURE INSTRUMENTS BE IMPROVED?

Page 6: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

GPERS composite technologies are continually updating and improving.

Miniaturization of individual modular components of the GPERS system has allowed the weight burden to be reduce to < 8 pounds!

Surveyor safety is improved greatly with its lightweight and diminished size (integrated system almost unnoticeable for surveyor and allows near uninhibited agility).

GLOBAL POSITIONING ENVIRONMENTAL RADIOLOGICAL

SURVEYOR

Page 7: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Data is collected or monitored: Locally to a data logger with display to monitor a trace of his survey path and current radiological readings in real-time to verify coverage of any given area. Areas that exceed a user-set radiological trigger point activate an audio cue and are visually highlighted to provide instant notification.

Transmitted via Bluetooth® to a local wireless network/cloud.

Real-time data classification and analysis can be conducted remotely and simultaneously with field teams.

GPERS ENHANCEMENTS

Page 8: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Lightweight yet rugged and with improved accuracy. All system components performed without incident while surveying robotically in a 150 R/hr area.

Improved data accuracy quality in a quicker time frame makes “informed” project managers resulting in better efficiency and cost savings.

Large data sets rendered to virtually any AutoCAD or GIS format provides easily understandable graphical representations of otherwise quite an overwhelming volumes of data.

GPERS ADVANTAGES

Page 9: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

GPERS MAPS - CHARACTERIZATION SURVEY

Page 10: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

GPERS MAPS – FINAL STATUS SURVEY

Page 11: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Instrument primarily used for quick surveys not extensive data collection

Users like an analog display rather than digitalErgonomic improvements were not considered importantWent through several variations on handles, but users liked

old styleDurability is important.Familiar packaging styles was preferredCalibrations importantReliable battery power importantWeight reduction is a good goal

FEEDBACK FROM USERS

Page 12: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

ESI MODEL 20 ION CHAMBER

Page 13: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Older generation instruments used taut-band meters that were susceptible to movement-induced needle wobble. New instruments utilize microcontroller / gear-reduced stepper motor design to eliminate the wobble while keeping the familiar look.

Temperature and pressure sensors are used to automatically compensate the readings, alleviating the user from tedious manual corrections for atmospheric pressure.

ESI MODEL 20 ION CHAMBER

Page 14: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Consumable materials, such as the desiccant, are viewable without opening the case.

Rechargeable batteries reduce the need to open the instrument case.

Access within the case is easier, including a threaded chamber with no attaching cable, which allows extremely easy replacement.

The instruments are getting lighter.

ESI MODEL 20 ION CHAMBER

Page 15: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

Most important, the new generation ESI Model 20 is calibrated from a computer through the USB port. This allows all ranges to be calibrated quickly from a

single point and reduces the exposure of the calibration technician to the calibration sources.

User-definable settings can be set at the same time and stored in the non-volatile memory.

CALIBRATION

Page 16: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

CALIBRATION SCREENSHOT

Page 17: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

ESI Model 20 provides a recognizable instrument easily useable by personnel experienced in ion chamber meters.

However, unit is a platform for more extensive usage.

Digital operation allows expansion of capabilities.Can be used for data collection.

NEW PLATFORM

Page 18: ESI Model 20 Ion Chamber EVOLUTION OF THE ION CHAMBER HPIC Meeting September 25, 2012 Presented by Jim Shiley.

QUESTIONS?