+ All Categories
Home > Documents > esigned with 3M Novec len ent ol otetion Fire Protection...

esigned with 3M Novec len ent ol otetion Fire Protection...

Date post: 17-Oct-2020
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
2
Calle Eucalipto 11 P. I. La Sendilla 28350 Ciempozuelos (Madrid, Spain) T: +34.918.762.146 / F: +34.918.762.146 [email protected] Designed with: 3M Novec 1230 Fire Protection Fluid Clean Agent Local Protection ACCORDING SEVO™ Flex™ utilizing 3M™ Novec™ 1230 Fire Protection Fluid offers the unprecedented flexibility of providing localized protection of high value equipment for maximum efficiency and cost effectiveness. SEVO™ Flex™ is designed to meet the rapid discharge time (up to 10 seconds) in accordance with NFPA 2001. Multi- Point provides partial/local flooding of a single or multiple hazards. The SEVO™ Flex™ Multipoint Pre-engineered Automatic Clean Agent Fire Suppression System utilizes unique flexible detection tubing attached to the top of the cylinder valve. This tubing is pressurized with Nitrogen to 16.5 bar (240 PSIG) maintaining cylinder valve closure. The detection tubing is temperature sensitive, and acts as a continuous linear thermal detector that ruptures at approximately 120 ºC (248 ºF) or 180 ºC (356 ºF). When the detection tubing ruptures, the cylinder valve is actuated, allowing Novec TM 1230 fluid to flow through the discharge on the Flex valve, distributing the extinguishing agents through the nozzles into the protected hazard area. FEATURES · Automatic and Autonomous · Multi sensor and multi extinguishing jets · Linear detection line · Rapid reaction time · Ready for use 24 hours & 365 days · No external power supply required OPTIONAL · Manual release device · Actuation solenoid · Low pressure switch · Pressurization adapter · End of line gauge ENVIRONMENTALLY FRIENDLY With zero ozone depleon potenal, extremely low global warming potenal and short atmospheric lifeme, Novec 1230 Fluid is the first chemical halon replacement to offer a viable, long- term, sustainable technology for special hazards fire protecon. APPLICATIONS Electrical Cabinet PLC Modules Communication Racks CNC Production Lines Vehicles Industrial Machinery Generator Room Engine Room Cash Machine Warehouse and Archive Industrial Filters Laboratory Aeronautic Transport Wind Mill Marine Militar Applications
Transcript
Page 1: esigned with 3M Novec len ent ol otetion Fire Protection Fluiddonar.messe.de/exhibitor/interschutz/2015/D529159/sevo-flex-sale... · Fire Protection Fluid len ent ol otetion ACCORDIN

Calle Eucalipto 11 P. I. La Sendilla28350 Ciempozuelos (Madrid, Spain)

T: +34.918.762.146 / F: [email protected]

Designed with:

3M™ Novec™ 1230 Fire Protection Fluid

Clean Agent Local Protection

ACCORDING

SEVO™ Flex™ utilizing 3M™ Novec™ 1230 Fire Protection Fluid offers the unprecedented flexibility of providing localized protection of high value equipment for maximum efficiency and cost effectiveness.

SEVO™ Flex™ is designed to meet the rapid discharge time (up to 10 seconds) in accordance with NFPA 2001. Multi-Point provides partial/local flooding of a single or multiple hazards.

The SEVO™ Flex™ Multipoint Pre-engineered Automatic Clean Agent Fire Suppression System utilizes unique flexible detection tubing attached to the top of the cylinder valve. This tubing is pressurized with Nitrogen to 16.5 bar (240 PSIG) maintaining cylinder valve closure.

The detection tubing is temperature sensitive, and acts as a continuous linear thermal detector that ruptures at approximately 120 ºC (248 ºF) or 180 ºC (356 ºF).

When the detection tubing ruptures, the cylinder valve is actuated, allowing NovecTM 1230 fluid to flow through the discharge on the Flex valve, distributing the extinguishing agents through the nozzles into the protected hazard area.

FEATURES · Automatic and Autonomous

· Multi sensor and multi extinguishing jets

· Linear detection line

· Rapid reaction time

· Ready for use 24 hours & 365 days

· No external power supply required

OPTIONAL

· Manual release device

· Actuation solenoid

· Low pressure switch

· Pressurization adapter

· End of line gauge

ENVIRONMENTALLY FRIENDLYWith zero ozone depletion potential, extremely low global warming potential and short atmospheric lifetime, Novec 1230 Fluid is the first chemical halon replacement to offer a viable, long-term, sustainable technology for special hazards fire protection.

APPLICATIONSElectrical Cabinet PLC Modules

Communication Racks CNC

Production Lines Vehicles

Industrial Machinery Generator Room

Engine Room Cash Machine

Warehouse and Archive Industrial Filters

Laboratory Aeronautic

Transport Wind Mill

Marine Militar Applications

Page 2: esigned with 3M Novec len ent ol otetion Fire Protection Fluiddonar.messe.de/exhibitor/interschutz/2015/D529159/sevo-flex-sale... · Fire Protection Fluid len ent ol otetion ACCORDIN

Calle Eucalipto 11 P. I. La Sendilla28350 Ciempozuelos (Madrid, Spain)

T: +34.918.762.146 / F: [email protected]

Designed with:

3M™ Novec™ 1230 Fire Protection Fluid

Clean Agent Local Protection

SEVO™ FLEX MULTIPOINTPNEUMATIC ACTION

The SEVO™ Flex™ Multipoint Pre-Engineered Automatic Clean Agent Fire Suppression Systems utilizes unique flexible detection tubing attached to the top of the cylinder valve. This tubing is pressurized with Nitrogen to 240PSIG (16.5 bar) maintaining cylinder valve closure. The detection tubing is temperature sensitive and acts as a continuous linear thermal detector that ruptures at designated temperatures. When the tubing ruptures, the cylinder valve is actuated, allowing Novec 1230 fluid to flow through the discharge outlet on the Flex valve, distributing the extinguishing agent through the nozzle(s) into the room.

ELECTRICAL ACTION

The SEVO™ Flex™ Multipoint Electrical Actuation System utilizes a control panel with conventional detectors sensing products of combustion at the incipient stage or a Thermal Line will detect a range of temperatures depending on the hazard type. An electric solenoid on the top of the valve will discharge to the system.Control panel features allow options such as cellular calling as well as communication to the building fire alarm panel.

Pneumatic Detection Tubing 120-180ºC

Integrated Manual Actuator

Manual Actuator

ACCORDING

Linear Heat Wiring

System Sensor Detectors

Control PanelEN 54 - 12094-1


Recommended