American Security Products ESLAudit Operating Instructions ESLAudit Access Control System Operating Instructions
Transcript
Page 1: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

American Security Products ESLAudit Operating Instructions

ESLAuditAccessControlSystemOperatingInstructions

Page 2: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

1

ContentsIntroduction...................................................................................................................................3Keyboard........................................................................................................................................3Login...............................................................................................................................................3LoginwithPIN/Key.....................................................................................................................3LoginwithPINOnly....................................................................................................................4LoginwithKeyOnly(thisoptionisonlyavailableonnon-listedversions).................................4

OpenLock.......................................................................................................................................4WithoutTimeDelay...................................................................................................................4WithTimeDelay.........................................................................................................................4

Batteries.........................................................................................................................................4ChangingtheBatteries...............................................................................................................4BatteryLife.................................................................................................................................4

AdjustingDisplayBrightness..........................................................................................................4AdjustingBeeperVolume...............................................................................................................5ChangingLanguage........................................................................................................................5ImmediateLock..............................................................................................................................5EngagingImmediateLock...........................................................................................................5EnablingImmediateLock(thisisanadministrative)..................................................................5

DownloadanAudit.........................................................................................................................5ControllerSettings..........................................................................................................................6BackingUpControllerSettings...................................................................................................6RestoringControllerSettingsfromaBackupFile.......................................................................6

ChangePIN.....................................................................................................................................6UserAdministration.......................................................................................................................7AddingUsers(restrictedtomanaginguserlevels).....................................................................7EditingaUser’sProfile(restrictedtomanaginguserlevels)......................................................7DeletingaUser(restrictedtomanaginguserlevels).................................................................7Enabling/DisablingaUser(restrictedtomanaginguserlevels).................................................8PurgingAllUsers(restrictedtohighermanaginguserlevels)....................................................8

DualControl(restrictedtoAdministrativeuserlevels)..................................................................8Time&DateControls.....................................................................................................................8SettingTimeDelay(restrictedtoadministrativeuserlevels)....................................................8TimeLock(restrictedtoadministrativeuserlevels)..................................................................9DaylightSavingsTime(restrictedtoadministrativeuserlevels)................................................9ChangingDateandTime(restrictedtomanaginguserlevels)...................................................9HolidayLockout(restrictedtomanaginguserlevels)..............................................................10

UpdateSoftware..........................................................................................................................10

Page 3: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

2

ESLConfig......................................................................................................................................10System&LockSetup................................................................................................................11DaylightSavings....................................................................................................................11Duress...................................................................................................................................11AuxInput..............................................................................................................................11Holidays................................................................................................................................12LockSetup............................................................................................................................12LockType..............................................................................................................................12DoorHoldTime....................................................................................................................12DoorOpenTime...................................................................................................................12DualControl.........................................................................................................................12ImmediateLock....................................................................................................................12TimeDelay............................................................................................................................12DelayPeriod.........................................................................................................................12OpenPeriod.........................................................................................................................12TimeLock.............................................................................................................................13

UserSetup................................................................................................................................13EditUsers.............................................................................................................................13TypesofUsers......................................................................................................................13

ViewanAudit...............................................................................................................................14

Page 4: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

3

IntroductionTheAMSECESLAuditlockisaflexible,multi-featuredsafelockthatisintendedforone-andtwo-doorsafes.Keyfeaturesofthislocksysteminclude:

• 2,000secureauditrecords.• 40userswithuniquesecurityprivilegesandauthoritylevels.• PCapplicationformanagingsystemconfigurationandusers.• USBinterfaceforquickandcost-effectivesoftwareupgrades,systemconfigurationand

Audits.• Abilitytocontrol1or2doors.Safedoorscanbeconfiguredinanyinner/outer

arrangement.• TimeDelayfeature,whichprovides1-99minutedelayand1-99minuteOpenPeriod

withcancelfeatureonanydoor.• TimeLock,whichallowslimiteddooropeningperiods,1-6windowsperday.• Authenticationoptions:PINcodeand/orDallasKeyaccesscontrol.• Wrongtrycount–penaltylockout.• Armoredcar(courier)bypassforTimeDelayandTimeLock.• Holidaylockoutschedulewithupto16programmableeventsperyear.• Automaticdaylightsavingsadjustment,selectableandconfigurable.• DualControlmodeonanyindividualdoor.• Auditutility,whichallowsPC-basedauditstoragemanagement,datafilterandsorting.• Highcontrast4linesby21charactersbacklitgraphicsdisplay.• OptionalburglaryorduressalarmoutputwithACpowerandexternalcontrolinput.• SupportsEnglish,SpanishandFrench.

KeyboardThefoursoftkeys locatedbelowthedisplayperformthefunctionsthatareshownonthe lastlineofthedisplayabovetheapplicablekey.TheMENUbuttonbringsyoubacktotheMainMenu.TheYES/NOkeyisusedtotogglesettingsbetweenYES/NO,ON/OFForEnable/Disableinsomesetupmenus.TheQUITkeytakesyoubacktothepreviousmenu.TheENTER/SAVEkeyisusedtosavechangesorenterdataafterdataentry.Login

LoginwithPIN/Key1. Presentkey.2. EnterPIN.3. PressENTER/SAVEkey.

Page 5: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

4

LoginwithPINOnly1. EnterPIN.2. PressENTER/SAVEkey.

LoginwithKeyOnly(thisoptionisonlyavailableonnon-listedversions)

1. Presentkey.

OpenLock

WithoutTimeDelay1. Login2. Pressthesoftkeylocatedbelowthedisplayontheleft.Open1forDoor#1orOpen2

forDoor#2.3. Afteryouhearaclick,opendoorwithin4seconds.

WithTimeDelay

1. Login2. PressthesoftkeylocatedbelowthedisplayontheleftOpen1orOpen2.3. WaitfortheTimeDelaycountertoreachthepresetTimeDelay.4. Loginagain.5. Afteryouhearaclick,opendoorwithin4seconds.

Batteries

ChangingtheBatteriesThebatterycompartmentislockedonthebottomofthecontrollerandholdstwo9-voltbatteries.Pinchthereleasecatchestowardthecenteroneithersidetoreleasethetray.

BatteryLife

Thepercentageof remainingbattery life isdisplayedon theLOCKEDscreen.To reachtheLOCKEDscreen,pressanykeywhenthelockissleeping.Ifthecontrollerisawake,pressQUITuntiltheLOCKEDscreenappears.

AdjustingDisplayBrightness

TheDisplayBrightnessscreenisaccessedfromtheLOCKEDscreen.

1. PresstheMenukeytwice.2. PresstheMoresoftkey3times.3. Usethe­and¯softkeysuntilthebacklightbargraphisblinking.4. Use¬and® softkeystoadjustbrightness.5. Pressthe“OK”key.

Page 6: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

5

AdjustingBeeperVolume

1. PresstheMenukeytwice.2. PresstheMoresoftkey3times.3. Usethe­and¯softkeysuntilthebeepervolumebargraphisblinking.4. Use¬and® softkeystoadjustvolume.5. Pressthe“OK”key.

ChangingLanguage

1. PresstheMenukeytwice.2. PresstheMoresoftkey3times.3. Usethe­and¯softkeysuntilthelanguageisblinking.4. Use¬and® softkeystoadjustlanguage.5. Pressthe“OK”key.

ImmediateLock

EngagingImmediateLockThis feature is usedwhen Time Lock is enabled and the safe is in an open period. IfImmediateLockisselected,thesafeisplacedinaone-TimeLockoutuntilthenextopenperiod.

1. Login.2. Pressthe“1”(I-Lock)keyfromtheMainMenu.3. SelectOpen1orOpen2usingthesoftkeysbelowtheleft-handsideofthedisplay.4. Enterthenumberofhoursthatyouwantthesystemtoremainlockedout,upto144

hours.5. PressENTER.Thesystemwilldisplaythetimeanddatewhenthelockoutperiodwill

end.Writethatdownsoyourememberit.

EnablingImmediateLock(thisisanadministrative)1. Login.2. Press“3”(Admin).3. Press“3”(Access).4. Press“1”(DoorAccess).5. Press“3”(ImLock).6. EnableordisablethefeatureforLock1withthe“YES/NO”key.7. Pressthe“OK”softkeytosavethechange.8. Ifapplicable,repeatsteps6and7forthesecondlock.

DownloadanAudit

1. Login.2. Pressthe“2”(Audit)keyfromtheMainMenu.

Page 7: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

6

3. InserttheUSBflashdriveintotheUSBconnectoronthebottomofthecontroller.4. Pressthe“OK”softkeylocatedbeneaththedisplayontheright-handside.5. Afterthedownloadiscomplete,removetheUSBflashdrive.6. AuditscanbedownloadedontoaPCwiththeuseof“ESLDat”software.

ControllerSettings

BackingUpControllerSettingsIf you are an ESLAudit lock administrator, it is recommended that you back up thesettingsofeachlockyouareresponsibleformanaging.Eachtimeyouchangeasettingonthelock,youwillbeaskedtodoabackupbyinsertingaUSBFlashdriveintotheUSBconnector. If you aremanagingmultiple locations, each location should use a uniqueFlashdrivetoavoidover-writingdatafromothersystems.

1. Login.2. Press“4”(USB).3. Press“1”(SaveSystem).4. InsertUSBflashdrive.5. Pressthe“OK”softkey.

RestoringControllerSettingsfromaBackupFile

Caution:RestoringthesystemconfigurationfromtheUSBFlashdrivewillover-writeallcurrentsystemsettings.IfyouhavemadeanychangestotheconfigurationorusersattheControllerwithout saving them, then thebackupyouare loadingwill cause thosechangestobelost.Youshouldalwaysbackupthesystemafteranychange,andusethatBackupasthebaseforalterationswithESLConfigandrestoration.

1. Login2. Press“4”(USB).3. Press“2”(LoadSystem).4. InsertUSBflashdrive.5. Pressthe“OK”softkey.6. Pressthe“OK”softkey.

ChangePIN

1. Login2. Press“3”(Admin).3. Press“1”(PINchg).4. EnternewPIN.5. Pressthe“OK”softkey.6. EnternewPINagain.7. Pressthe“OK”softkey.

Page 8: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

7

UserAdministration

AddingUsers(restrictedtomanaginguserlevels)1. Login.2. Press“3”(Admin).3. Press“2”(Users).4. Press“1”(Add).5. SelectUserProfilewithsoftkeys.6. PressENTER/SAVEkey.7. Selectlogintypewithsoftkeys(key/PIN,PINonly,keyonly).8. PressENTER/SAVEkey.9. Ifapplicable,youwillbeaskedtopresentthekeytothekeyreader.10. Enterusername.11. PresstheENTER/SAVEkey.Ifyouenrollanewkey/PINuser,theuserwillbeenrolledwithaninitialPINof1,1,1,1,1,1.IfyouenrollaPIN-onlyuser,theinitialPINwillbetheirtwodigitusernumberfollowedbysix1’s(X,X,1,1,1,1,1,1).TheuserwillberequiredtoenteranewPINuponfirstlogin.PINsthatareinusebyanotheruserorthataredeemedtoosimplewillnotbeallowed.UserscanalsobeenrolledwiththeuseofaPCapplicationcalledESLConfig.

EditingaUser’sProfile(restrictedtomanaginguserlevels)

1. Login.2. Press“3”(Admin).3. Press“2”(Users).4. Press“2”(Edit).5. Use¬and® softkeystoscrolltofindtheuseryouwishtoedit.6. PresstheENTER/SAVEKeytoselecttheuser.7. Selectauserprofileusingthe¬and® softkeys.8. PresstheENTER/SAVEKey.9. Selectauserlogintype.10. PresstheENTER/SAVEkey.11. Presenttheuser’sDallaskeytothereader(ifapplicable).12. Edittheusername.13. PresstheENTER/SAVEkey

DeletingaUser(restrictedtomanaginguserlevels)

1. Login.2. Press“3”(Admin).3. Press“2”(Users).4. Press“3”(Delete).5. Usethe¬and® softkeystoscrolltofindtheuseryouwishtoedit.6. PresstheENTER/SAVEkeytoselecttheuser.

Page 9: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

8

7. Confirmyourwishtodeletetheuserwiththe“OK”softkey.

Enabling/DisablingaUser(restrictedtomanaginguserlevels)1. Login.2. Press“3”(Admin).3. Press“2”(Users).4. Press“4”En/Disable.5. Usethe¬and® softkeystoscrolltofindtheuseryouwanttoenable/disable.6. PresstheENTER/SAVEkeytoselecttheuser.7. Confirmyourwishtochangethestatusoftheuserwiththe“OK”softkey.

PurgingAllUsers(restrictedtohighermanaginguserlevels)

1. Login.2. Press“3”(Admin).3. Press“2”(Users).4. Press“5”(Purge).5. Confirmyourwishtopurgeallusersexceptyourselfwiththe“OK”softkey.

DualControl(restrictedtoAdministrativeuserlevels)

Thisfeaturerequirestwousersworkingtogethertoopenaspecifieddoor.

1. Login.2. Press“3”(Admin).3. Press“3”(Access).4. Press“1”(DoorAccess).5. Press“2”(DualCnt).6. EnableordisablethefeatureforLock1withthe“YES/NO”key.7. Pressthe“OK”softkeytosavethechange.8. Ifapplicable,repeatsteps6and7forthesecondlock.

Time&DateControls

SettingTimeDelay(restrictedtoadministrativeuserlevels)Thisfeaturedelaystheopeningofaspecifiedlockforaspecifiedamountoftime.

1. Login.2. Press“3”(Admin).3. Press“3”(Access).4. Press“1”(DoorAccess).5. Press“1”(TDelay).6. Eachlockhasitsownscreen.7. Turnfeatureon/offwiththeYES/NOkey.8. Scrolltootherfieldsusingthesoftarrowkeys.9. “Delay”isthenumberofminutesthatopeningwillbedelayed.

Page 10: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

9

10. “Open”isthenumberofminutesfortheopenwindow.Userscanonlyopenthesafeforthatamountoftime.Iftheywaitlongerthanthespecifiedamountoftime,theywillhavetostarttheprocessover.

11. Pressthe“OK”softkeytogettothescreenforthesecondlock,ifapplicable.12. PresstheENTER/SAVEkeytosaveyourchanges.

TimeLock(restrictedtoadministrativeuserlevels)Thisfeatureestablisheswindowsoftimewhenthesafecanbeopened.TheopenwindowscanonlybeprogrammedwiththeuseofthePCapplicationESLConfig.Thisfeaturecanbeturnedon/offbyauserwiththeappropriateauthorityatthecontroller.

1. Login.2. Press“3”(Admin).3. Press“3”(Access).4. Press“1”(DoorAccess).5. Press“2”(TmLock).6. EnableordisablethefeatureforLock1withthe“YES/NO”key.7. Pressthe“OK”softkeytosavethechange.8. Ifapplicable,repeatsteps6and7forthesecondlock.

DaylightSavingsTime(restrictedtoadministrativeuserlevels)

1. Login.2. Press“3”(Admin).3. Press“3”(Access).4. Press“2”(DaylightSavings).5. EnableordisablethisfeaturewiththeYES/NOkey.6. Pressthe“OK”key.7. Setthebeginningtime.8. Usethe­and¯softkeystochangefieldvalues.9. Usethe¬and® softkeystomovebetweenfields.10. Pressthe“OK”key.11. Settheendtime.12. Usethe­and¯softkeystochangefieldvalues.13. Usethe¬and® softkeystomovebetweenfields.14. Pressthe“OK”key.

ChangingDateandTime(restrictedtomanaginguserlevels)

1. Login.2. Press“3”(Admin).3. Press“3”(Access).4. Press“4”(Date/Time).5. Usethenumberkeystoenterdata.6. Usethesoftarrowkeystomovebetweenfields.7. PresstheENTER/SAVEkeytosaveyourchanges.

Page 11: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

10

HolidayLockout(restrictedtomanaginguserlevels)Thisfeatureallowsuserswithcertainauthoritiestoestablishaholidayschedule.Ontheseestablisheddays,thesafecannotbeopened.Thereareamaximumofeightstoredholidays.

1. Login.2. Press“3”(Admin).3. Press“3”(Access).4. Press“3”(HolidayLockouts).5. Usethenumberkeystoenterdata.6. Usethesoftarrowkeystomovebetweenfields.7. PresstheENTER/SAVEkeytomovetoscreen2.8. Usethenumberkeystoenterdataonscreen2.9. Userthesoftarrowkeystomovebetweenfields.10. PresstheENTER/SAVEkeytosaveyourchanges.

UpdateSoftware

1. Login.2. Press“4”(USB).3. Press“3”(FirmwareUpdate)4. InserttheUSBFlashdriveintotheUSBconnectorlocatedonthebottomofthe

controller.5. Pressthe“OK”softkey.6. Pressthe“OK”softkey.7. Thesystemwillnowreboot.8. RemovetheUSBFlashdrivewhencomplete.

Note:Usersettingsandsystemconfigurationarenotchangedwiththisprocess.ESLConfig

ESLConfigisaPCapplicationthatallowsuserstomodifythesettingsofanESLAuditsystem.Tousethisutility,youmustfirstdownloadthesystemsettingsfromtheapplicablecontroller(seepage6).AftertheESLConfigprogramisinstalledonaPCandtheprogramisrunning,inserttheflashdriveintothePC’sUSBport.FromtheFilemenuonthetopleftofthescreen,selectOpen,and then choose the appropriate file on the flash drive. The name of the file saved by thecontrollerwillbeESLAUDIT.EAS.Backup copies of system configurations can be saved. To save a backup copy of theconfiguration,selectFileatthetopleft-handcornerofthewindowandchooseSave.Thiswillsaveabackupcopywiththefilenameofthecontrollerserialnumberfollowedbythedateandtime the file was saved by the controller (EAxxxxxxx.yy.mm.dd.hh.mm). The file type is ESLSetup(.EAS).

Page 12: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

11

TomoveacopyofasystemconfigurationfromESLConfigtoacontroller,selectFileatthetopleft-handcornerof thewindow, chooseOutput toFlashDrive, and then chooseAll. ThiswillsavetheconfigurationfilewiththenameESLAUDIT.EAS.Toloadtheconfigurationfileintothecontroller,seepage6.Settingsaremodifiedonthescreensthatareshownbelow:

System&LockSetup

DaylightSavingsAutoDaylightSavingsEnablewillcausethesystemclocktochangeappropriatelyontheSundaymorningoftheindicatedweek.DuressDuress Alarm Enable will activate duress codes. Duress codes are both one numberhigherandonenumberlowerthananyPINvalue.Forexample,ifyourPINis515151,ifyoulogintothesystemwitheitherPIN515152or515150,aduresssignalwillbesenttothemonitoring station through the store’s alarm system. For this feature to function,theoptionalACexpansionmodulemustbeinstalledandconnectedtothestore’salarmsystem.AuxInputAuxInputisafeaturethatallowsanoptionalswitchtobeinstalledintotheoptionalACexpansionmodule. If this feature is installed and enabled and Time Lock is enabled,

Page 13: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

12

when the switch is pressed, the safe is put into immediate lockout the Aux Input isopenedandthereisanappropriateTimeLockOpenPeriod.HolidaysScheduled holidays are days that the safe cannot be opened. The lockout runs frommidnighttomidnight.

LockSetupThe bottom half of the screen is used for lock settings. You can move between thesettingsforLock1andLock2byusingthePrev.andNextbuttonsonthebottomofthescreen.

LockTypeThissettingiscurrentlyunusedatthistime.DoorHoldTimeThissettingcontrolsthenumberofsecondsthatauserhastoopenthedooraftertheappropriateopendoorsoftkeyispressed.

DoorOpenTimeThissettingcontrolsthenumberofminutesthedoorcanbeleftopenbeforethealarmgoesoff.

DualControlThisrequirestwouserstoopenthespecifieddoor.

ImmediateLockIf Immediate Lock is enabled and Time Lock is enabled, when a user with theappropriatepermissionspressesI-lock(1)fromtheMainMenuandselectsadoor,theselecteddoorisputintoaone-TimeLockoutuntiltheendoftheI-Lockperiod.

TimeDelayToenablethisfeature,checktheTimeDelayboxfortheapplicablelock.DelayPeriodThis is the number of minutes that must elapse before the applicable door can beopened.OncetheDelayPeriodhaspassed,theuser(s)willhavethenumberofminutesintheOpenPeriodtologinandopentheapplicabledoor.OpenPeriodThisistheamountoftimeauserhastologinandopenadooraftertheDelayPeriodhaspassed.IftheOpenPeriodpasses,userswillhavetologinandwaitforanewDelayPeriodtoexpirebeforetheywillbegiventheopportunitytoopenthedoor.

Page 14: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

13

TimeLockTheTimeLockboxmustbecheckedtoenable this feature.Whenenabled,a lockcanonlybeopenedduringanopenperiod.Uptofouropenperiodscanbedefinedforeachdayoftheweek.Foreachopenperiod,thestartingtimeisestablishedOpenTimeandthedurationofeachopenperiodisspecifiedinhours.Settingsareestablishedforeachdayoftheweek.Byclickingonanyofthethreeduplicatedisplaysettingboxes,youcancopythesettingsforthedaythatisdisplayedtootherdays.

UserSetup

ThesecondtabintheESLConfigprogramistheUserSetuptab.

EditUsersToeditusers,scrollthroughtheusernumberswiththePrev.andNextbuttonslocatedontheupperrightoftheUserSetupscreen.TheAddandDelbuttonsareusedtoaddordeleteauser.TypesofUsersThereareeightstandarduserprofileswithpredeterminedpermissions:

Door1UserDoor2UserDoor1-2User

Page 15: ESLAudit Access Control System Operating Instructions · 4. Enter the number of hours that you want the system to remain locked out, up to 144 hours. 5. Press ENTER. The system will

14

ManagerAuditorRegionalManagerCourierSuperUser

Youcanreviewthespecificpermissionsofeachuserprofilebylookingatwhichpermissionboxesarecheckedafteraparticularprofileisselected.Youcangiveauseranysetofpermissionsbycheckingthecustomprofilebox.YoushouldassigneachuseraUsernamesoitshowsupintheAuditTrail.Accessmodesareusedtodefinekeyonly,PINonlyandkey/PINusers.YoucansavethefileforlaterusewithESLConfigbyclickingtheFiletabandthenselectingSave.Youcannotsafeafiletobeuploadedtoacontrollerwiththismethod.OntheFiletab,selectOutputtoFlashdriveandthenAlltosaveafilethatcanbeuploadedintoacontroller.ThenameofthisfilewillbeESLAUDIT.EAS.

ViewanAudit

1. InstalltheprogramESLDatontoyourPC.2. OpentheprogramESLDat.

3. SelectAuditTrail.4. SelecttheFileESLAUDIT.EAA.