Date post: | 28-Jul-2015 |
Category: |
Technology |
Upload: | cmul |
View: | 1,509 times |
Download: | 2 times |
Factory I - ITALY
Factory II - AUSTRIA
WHERE EUROCLIMA
IS LOCATED
EUROCLIMA ITALY EUROCLIMA AUSTRIA
Founded in 1963 by Dr. Ing. h.c. Josef Schmidhammer
Activities: Production and selling of Air Handling Units
actually 100 employee Annual turnover: 17,0 Mio. € Production area 11.000 m²
Founded in 1980 by Dr. Ing. h.c. Josef Schmidhammer
Activities: Production and selling of Air Handling Units
actually 65 employee Annual turnover: 10 Mio. € Production area 7.000 m²
EUROCLIMA HISTORY
BRUNICO AND SURROUNDINGS
ATEXATEX
GOST certificate for RUSSIA
GOST certificate for RUSSIA
Hygienic Hygienic certificatecertificate
ISO 9000ISO 9000
EUROVENTEUROVENT
Hygienic certificate for RUSSIA
Hygienic certificate for RUSSIA
EUROCILMA certificatesEUROCILMA certificates
• Create common basis to compare technical characteristcs, using new european and international standards
• The participants present the characteristics of all their products regarding AHUs and deposit the selection software
• The responsible of the certifications decide of which product of the range will be done the test.
• An indipendent test laboratory verifies the characteristics asked in the certification. This datas will be compared with the calculated datas.
EUROVENT CERTIFICATIONEUROVENT CERTIFICATION
Mechanical characteristics
The following mechanical characteristics are certified : a - Casing strength D2M (for ZHK2000 S)
D1M (for ZHK2000 I)
b - Casing air leakage under –400Pa L1 Casing air leakage under +700Pa L1c - Filter bypass leakage F9d - Thermal transmittance of the casing T4 e - Thermal bridging factor TB2 (for ZHK2000 S)
TB3 (for ZHK2000 I)f - Acoustical insulation of casing
Performance characteristics
The following mechanical characteristics are certified : a - Air flow - Available static pressure - power input b - Octave band in-duct sound power level c - Airborne sound power level d - Heating capacity* e - Cooling capacity* f - Heat recovery* g - Pressure loss on water side*
* If standard features of the product range
EUROVENT CERTIFICATIONEUROVENT CERTIFICATION
AIR HANDLING UNITSAIR HANDLING UNITS
ZHK 2000
Standard execution - ZHK2000 SS Inner skin: 1,00mm galvanized sheet
Outer skin: 0,70mm galvanized sheet with additional surface coating in plastic
Industrial execution - ZHK2000 II Inner skin: 1,50mm galvanized sheet
Outer skin: 1,00mm galvanized sheet with additional surface coating in plastic
ZHK 2000
- Double skin panels
- Assembled with self supporting panel elements
- Thermal and acoustic insulation
- Inside and outside comletely smooth
AIR HANDLING UNITSAIR HANDLING UNITS
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ZHK2000 Hygienic ExecutionZHK2000 Hygienic Execution
- Sloped drain pan SS in each section- Sloped drain pan SS in each section
- Components are side removable- Components are side removable- Inside sealed antibacteriological sealantInside sealed antibacteriological sealant- Fully washable unitFully washable unit-Semi-hygienic execution Semi-hygienic execution also also availableavailable
Hygienic Hygienic certificatecertificate
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ZHK2000 Hygienic ExecutionZHK2000 Hygienic Execution
Removable fan/motor assembly
with radial fans or plug fans
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ZHK2000 Hygienic ExecutionZHK2000 Hygienic Execution
Drain pan on filter section Sound attenuator removal
- Triple skin unit for FOOD INDUSTRYTriple skin unit for FOOD INDUSTRY
- Where commercial food processing hygiene Where commercial food processing hygiene is a mustis a must
- For simpliest cleaning inside of the unit and For simpliest cleaning inside of the unit and its componentsits components
- Interior consists of a welded tankInterior consists of a welded tank
- Rounding of all housing edges and cornersRounding of all housing edges and corners
ZHK2000 FI- executionZHK2000 FI- execution
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ZHK2000 FI- executionZHK2000 FI- execution
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
Product range „ETA“Product range „ETA“
- ETA POOL – for indoor swimming poolsETA POOL – for indoor swimming pools
- ETA PAC – with adiabatic coolingETA PAC – with adiabatic cooling
- ETA ROT – with heat recovery wheelETA ROT – with heat recovery wheel
- ETA ACCU – with high efficient heat recoveryETA ACCU – with high efficient heat recoveryeta
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA POOLETA POOL
Swimming pool unit
for private indoor pools (max. approx. 150 m²)
Air flow from 1.500 ......6.100 m³/h (5 unit sizes)
WR...…with heat recover heat pipe
PT....…with plate heat exchanger für middle and
bigger swimming pools
MAIN FEATURES:- Double heat recovery (heat recovery heat
pipe and heat pump circuit)- Integrated controls- Integrated heat pump with scroll
compressor
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
Most important characterisitcs:
Dehumidification of the air to avoid damage on the swimming hall
Exhaust of harmful gases who emerge from chlorine and from organic and inorganic substances
Keeping comfortable temperature and humidity in the swimming hall
Low energy consumption
ETA POOLETA POOL
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA PACETA PAC
Air handling unit with
adiabatic cooling
Air flow from 2.000 ......10.000 m³/h (4 unit sizes)
For rooms with high number of people like
restaurants, meeting rooms, sport halls, office
buildings, cinemas etc.
MAIN FEATURES:- Double heat recovery (double plate heat
exchanger and heat pump circuit)- Indirect adiabatic cooling- Integrated controls- Version DUO with integrated heat pump
with scroll compressor
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA PACETA PAC
Most important characterisitcs:
Heat recover with high sensible efficiency
Re-heating with warm water coil (if necessary)
Ecological cooling in two steps: - with plate heat exchanger
- with indirect adiabatic cooling
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA ROTETA ROT
Air handling unit with heat
and humidity recovery
Air flow from 7.500 ......25.000 m³/h (6 unit sizes)
For applications wher cooling and
dehumidification in summer is required and
heating and humidification are required in winter
like restaurants, sport halls, office buildings,
shops, etc.
MAIN FEATURES:- Enthalpy heat wheel- Integrated controls- ETA ROT “COOL” with integrated heat pump
with scroll compressor
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA ROTETA ROT
Most important characterisitcs:
High sensible heat recovery in SUMMER and WINTER (approx. 70%)
Latent heat recovery in SUMMER (approx. 40%)
Latent heat recovery in WINTER (approx. 70%)
Version “Cool” with refrigeration circuit and scroll compressor
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA ACCUETA ACCU
Air handling unit with
high efficient heat and
humidity recovery
Air flow from 1.800 ......11.000 m³/h (6 unit sizes)
For rooms where heating and humidity recovery
is necessary in winter time and cooling is
required in summer like restaurants, sport
halls, office buildings, shops etc.
MAIN FEATURES:- Double heat recovery accu bloc - Integrated controls- Version COOL with integrated heat pump
with scroll compressor
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA ACCUETA ACCU
Functional description of the Accu Bloc The accu bloc in front will be unloaded by cold external air; at same
time the accu bloc at the back will be heated (loaded) by the warm exhaust air
After changing air streams with the dampers in a fraction of a second, process will be repeated mirror-inverted.
EUROCLIMA CONSTRUCTION SERIESEUROCLIMA CONSTRUCTION SERIES
ETA ACCUETA ACCU
Most important characterisitcs:
Heat recovery with high sensible efficiency in summer of approx. 90%
High latent heat recovery in WINTER (approx. 75%) – through condensation
Version “Cool” with refrigeration circuit and scroll compressor
SPECIAL EXECUTIONSSPECIAL EXECUTIONS
HIGH TEMPERATURE UNITSHIGH TEMPERATURE UNITS
- Up to 300°C air temperatures- Up to 300°C air temperatures- available with motor located available with motor located
outside the air streamoutside the air stream- Available also with heat recovery Available also with heat recovery
(Heat Wheel)(Heat Wheel)
- Smoke exhaust units- Smoke exhaust units
SPECIAL EXECUTIONSSPECIAL EXECUTIONS
AHU‘s for ships - AISI 316 LAHU‘s for ships - AISI 316 L
- Available in various materials as - Available in various materials as
galvanized steel up to stainless steel galvanized steel up to stainless steel
AISI316L (inside and outside)AISI316L (inside and outside)- Coils frame (available from galvanized up - Coils frame (available from galvanized up
to stainless steel AISI316L) and fins and to stainless steel AISI316L) and fins and
tubes in copppertubes in coppper
-Special motors for ships (ABS, LR‘s, Special motors for ships (ABS, LR‘s,
DNV etc.) DNV etc.)
- 200mm heigh base frame with - 200mm heigh base frame with
integrated and insulated 140mm deep integrated and insulated 140mm deep
drain pandrain pan
SPECIAL EXECUTIONSSPECIAL EXECUTIONS
AHU‘s for shipsAHU‘s for ships
Filter safeFilter safe
- Hermetical filter frame for the filter classes Hermetical filter frame for the filter classes H10 to H14H10 to H14
- The tighthness in accordance with EN ISO The tighthness in accordance with EN ISO 14644 is guaranteed14644 is guaranteed
- Maximal air flow: 40.000 m³/hMaximal air flow: 40.000 m³/h
- Frame completely welded from stainless steel Frame completely welded from stainless steel 1.4301 (AISI304) profiles1.4301 (AISI304) profiles
- Especially used to install HEPA filters inside Especially used to install HEPA filters inside AHU‘sAHU‘s
SPECIAL EXECUTIONSSPECIAL EXECUTIONS
ASEPSISASEPSIS
SPECIAL EXECUTIONSSPECIAL EXECUTIONS
- Hygienic air handling unit made of glassfiber Hygienic air handling unit made of glassfiber reinforced plastic (Gfk)reinforced plastic (Gfk)
- Where commercial food processing hygiene Where commercial food processing hygiene is a mustis a must
- For simpliest cleaning inside of the unit and For simpliest cleaning inside of the unit and its componentsits components
- Panel thickness 50mmPanel thickness 50mm
- High thermal and acoustic insulationHigh thermal and acoustic insulation
- Rounding of all housing edges and cornersRounding of all housing edges and corners
- Air volumes up to 55.000 m³/hAir volumes up to 55.000 m³/h
IONEXIONEX
SPECIAL EXECUTIONSSPECIAL EXECUTIONS
Air handling unit with disinfection sistem for food industry
For food industries where hygienic clean air is absolutely required like meat industry, milk/cheese factories, water filling factories
Especially usable where “strong processes” like heavy heating is not allowed.
Protection of contamination of the products by a patented system: CoPlasma
MAIN FEATURES:- Disinfection in two steps (electrostatic filter
and decontamination with cold plasma)
Electrostatic
filter
SPECIAL EXECUTIONSSPECIAL EXECUTIONS
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
Hospitals and public buildings
Pharmaceutical-, food- and electronic industries
Shopping centres
Laboratories
Residential buildings
Hotels
AHU‘s for cruise liners, container ships and private yachts
OUR MAIN APPLICATIONSOUR MAIN APPLICATIONS
Country: UNITED ARAB EMIRATES
City: Dubai
Project: Hospital
Units installed: ZHK 2000 & ZHK2000 Hygienic units
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
BELHOUL HOSPITALBELHOUL HOSPITAL
FAIRMONT HOTELFAIRMONT HOTEL
Country: UNITED ARAB EMIRATES
City: Dubai
Project: Hotel and Residence
Units installed: 104 nos. ZHK2000
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
RIHAB ROTANA SUITESRIHAB ROTANA SUITES
AL MUSALLA TOWERAL MUSALLA TOWER
Country: UNITED ARAB EMIRATES
City: Dubai
Project: Office and residential building
Units installed: 33 nos ZHK 2000
14 nos ECO double skin 25mm
Country: UNITED ARAB EMIRATES
City: Dubai
Project: Residential building
Units installed: ZHK 2000
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
METROPOLITAN PALACE HOTELMETROPOLITAN PALACE HOTEL
RITZ CARLTON HOTELRITZ CARLTON HOTEL
Country: LEBANON
City: Beirut
Project: Luxurious 5 star HOTEL
38.000 m² built up area, 23 floors, 200 guest rooms
Units installed: 42 nos ZHK 2000
4 nos ZHK 2000 with heat wheel
Country: QATAR
City: Doha
Project: Luxurious 6 star Hotel
Units installed: 31 nos ZHK 2000
Country: UNITED ARAB EMIRATES
City: Dubai
Project: Luxurious 6 star Hotel – 1050 rooms
Units installed: 122 nos ZHK 2000
5 nos ZHK 2000 with heat wheel
119 nos ECO single skin decorative type
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
GRAND HYATT HOTELGRAND HYATT HOTEL
Country: UNITED ARAB EMIRATES
City: Dubai
Project: SHOPPING CENTER
Units installed: 165 nos.
Air volume: 2.000.000 m³/h
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
BURJUMAN EXPANSION PROJECTBURJUMAN EXPANSION PROJECT
Country: UNITED ARAB EMIRATES
City: Dubai
Project: SHOPPING CENTER
Units installed: 174 nos. AHU and 39 HRU
Air volume: 8.000.000 m³/h (Total)
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
THE DUBAI MALLTHE DUBAI MALL
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
MIRDIF CITY CENTER MALLMIRDIF CITY CENTER MALL
Country: UNITED ARAB EMIRATES
City: Dubai
Project: SHOPPING MALL
Units installed: 21 nos. FAHU & 114 nos. AHU
Year: 2008-2009 (under construction)
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
LATIFA TOWERLATIFA TOWER
Country: UNITED ARAB EMIRATES
City: Dubai
Project: RESIDENTIAL & OFFICE BLDG
Units installed: 16 nos. FAHU & 2 nos. AHU
Year: 2009 (under construction)
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
RIXOS OTTOMAN PALACE & VILLASRIXOS OTTOMAN PALACE & VILLAS
Country: UNITED ARAB EMIRATES
City: Dubai (ON PALM JUMEIRAH)
Project: LUXURY HOTEL AND RESIDENCE
Units installed: 93 nos. AHU
Year: 2008
Country: GERMANY
City: Eichstätt
Project: Production plant
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
OSRAMOSRAM
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
EUROCLIMA REFERENCESEUROCLIMA REFERENCES
NEWS
OP UNIT
T2 – TB2
KITCHEN EXTRACT UNIT
NEWSNEWS
Thank you…