WWW.TEST-FUCHS.COMTEST-FUCHS GmbH / Test-Fuchs Strasse 1-5 / A-3812 Gross-SieghartsT +43(0)2847 9001-0 / F +43(0)2847 9001-299 / [email protected] v 1.0
Evacuation Slides - Calibration Rig>EVS1-CR<
Developed for testing and calibrating regulatorvalves via discharge curve (pressure, time) forthe evacuation slide system (CO2/N2).
> Sound insulated design to protect theoperator
> Connection for exhaust equipment to guaranteesafe extraction of the escaping CO2/N2
> Portable CO2-warning device included in the scopeof delivery
> Adaption for reservoir absorption with regulatorvalve
> Hinged console with docking station for notebook
Page 1 / 3
PNEUMATICS / HYDRAULICS
WWW.TEST-FUCHS.COMTEST-FUCHS GmbH / Test-Fuchs Strasse 1-5 / A-3812 Gross-SieghartsT +43(0)2847 9001-0 / F +43(0)2847 9001-299 / [email protected] MAKO/BEKO
>EVS1-CR<
GENERAL INFORMATION
> Notebook with TEST-FUCHS software and pressure sensor
> Rail and tube clamping locks for test procedure
> Integrated fork lift access points for transport via fork lift truck
> Access door to test chamber with safety glass window for optimal observation
> Checkered plate ramp for easy access to the test chamber
> Tray lamp for optimal illumination of the test chamber
> Opening for activation rope
> Cable winch or cable winch mechanics optionally available (not included in the standard scope of delivery)
> “Special Tools“ are not included in the standard scope of delivery
Page 2 / 3
OPTIONS
Various options are available to meet our customers’ requirements.
Adaption for reservoir absorptionwith regulator valve
Hinged console with docking station for notebook
WWW.TEST-FUCHS.COM
>EVS1-CR<
TEST-FUCHS GmbH / Test-Fuchs Strasse 1-5 / A-3812 Gross-SieghartsT +43(0)2847 9001-0 / F +43(0)2847 9001-299 / [email protected] Page 3 / 3
Technical data are subject to change!
TECHNICAL DATA
> Hydraulic and pneumatic supplies (requirements):
- Exhaust equipment Tube diameter: 300mm (11.8in)
> Electrical supply (requirements):
Mains connection: 1/N/PE AC 50Hz 230VPerformance: 0.23kVANominal current: max. 1ABack-up fuse: 16AgG NH-type
> Measurements:
Pressure: 0 to 110bar (0 to 1595psi) ±0.15% of the measuring range
> Dimensions and weight:
- External measurements: Width: approx. 2,200mm (approx. 86.6in) Depth: approx. 2,500mm (approx. 98.4in) Height: approx. 2,300mm (approx. 90.6in)
- Internal dimensions: Width: approx. 1,650mm (approx. 65in) Depth: approx. 1,650mm (approx. 65in) Height: approx. 2,000mm (approx. 78.7in)
- Weight: approx. 980kg (approx. 2,161lb)
> Conditions of service:
Operating temperature: 5 to 35°C (41 to 95°F)
Storage temperature: 0 to 60°C (32 to 140°F)
Height: up to 1,000m (3,280ft) over MSL
Rel. air humidity: 5 to 95% (non-condensing)
Installation: Non-Ex-Area