Introduction Methods and Materials ELPs aliquots are kept frozen at -80C and once thawed they need to stay in ice to make sure that they do not undergo preliminary T t , to ensure the most accurate results. Both ELP stock solution and the drug solution, in this case Sildenafil (a well known vasodilator), are individually combined with 1xPBS buffer to determine the baseline assembly and disassembly behaviour of both the ELP and the sildenafil individually. ELP is then combined with the sildenafil and then diluted into the 1xPBS to create a solution to test the assembly and disassembly of the drug-loaded nanoparticles. A solution is then placed into the dynamic light scattering machine (DLS), and the intensity of the light scattering is measured, which is then used to derive volume. Figure 2 shows the special DLS cuvette. The DLS machine (Figure 3) measures Brownian Motion, the constant movement of particles due to collisions with other particles and liquids, to determine the size and therefore intensity of the particles. Results Thank you to Dr. Larry Unsworth, Abdullah Alshememry, Scott Elgersma, and all the members of Dr. Unsworth’s team for all your help within the lab throughout this program. A special thank you to NSERC Promo Science for the funding for my research this summer. Thank you to the WISEST Program for granting me this opportunity. My lab partners, Rebecca Probst and Gabrielle Smith for their help and support throughout this experience. Evaluation of Assembly and Disassembly Behaviour of Drug-Loaded Peptide Nanoparticles Mackenzie Fix, Abdullah Alshememry, Larry D. Unsworth Department of Chemical and Material Engineering, University of Alberta National Institute for Nanotechnology, Edmonton, Alberta Conclusions Elastin-Like Polypeptides (ELPs) are repetitive artificial polypeptides. The most common of ELP is in the form (VPGXG) n where X is a guest residue, and n is the number of pentapeptide repeats. ELPs in the form of (VPGXG) n exhibit an inverse temperature phase transition (T t ), meaning that below this temperature they are soluble in aqueous solution, and above the T t they undergo an aqueous demixing phase transition resulting in aggregation of the ELP. The tunable properties and the T t of the ELP make them well-suited for drug delivery within the body. Figure 1 shows the reversible phase transition behavior of ELPs. Literature Cited MacEwan, S. R. and Chilkoti, A. (2010), Elastin-like polypeptides: Biomedical applications of tunable biopolymers. Biopolymers, 94: 60–77. doi:10.1002/bip.21327 Bahniuk MS, Alshememry A, Unsworth LD. High yield expression of short chain elastin-like polypeptides. Biotechniques. 2016 Malvern Instruments LTD. (2003, 2004). Zetasizer Nano Series User Manual. Retrieved from http://www.biophysics.bioc.cam.ac.uk/files/Zetasizer_Nano_user_manual_Man0317-1.1.pdf Figure 3: An image of the DLS instrument used in the lab. DLS Instrument Theory Brownian motion is the movement of particles due to random collisions with the liquid that surrounds the particle, therefore the particles are always moving. An important part of Brownian motion for DLS is that small particles move quickly while large particles move slowly. Figure 4: An image of scattered light exhibiting bright and dark area fluctuations as found in the Zetasizer Nano Series User Manual (Malvern Instruments LTD., 2003, 2004.) Figure 2: An image of the special cuvette carrying the mixture of ELP and Sildenafil Figure 1: An image of the reversible phase transition behavior of ELPs 5 15 30 40 0 5 10 15 20 25 0.01 0.022 0.048 0.106 0.231 0.508 1.114 2.443 5.359 11.755 25.785 56.56 124.064 272.134 596.925 1309.353 2872.063 6299.863 ELP L40 0.1mg/ml Heating 5 15 30 40 0 5 10 15 20 25 30 0.01 0.021 0.044 0.092 0.192 0.403 0.844 1.768 3.703 7.756 16.244 34.023 71.26 149.25 312.596 654.717 1371.272 2872.063 6015.396 ELP L40 0.1mg/ml Cooling Due to the movement of the particles, constructive and destructive phase addition of scattered light will lead to dark and bright area fluctuation (Figure 4), therefore it is said that the intensity at any particular point fluctuates. These fluctuations and the idea that large particles will lead to slow fluctuations and small particles will have quick fluctuations is what the DLS machine uses to calculate a size distribution. 5 15 30 40 0 10 20 30 40 50 0.01 0.02 0.04 0.08 0.16 0.32 0.64 1.279 2.559 5.117 10.234 20.466 40.93 81.855 163.699 327.379 654.717 1309.353 2618.546 5236.771 ELP L40 0.5mg/ml Cooling 5 15 30 40 0 5 10 15 20 25 30 35 40 0.01 0.022 0.048 0.106 0.231 0.508 1.114 2.443 5.359 11.755 25.785 56.56 124.064 272.134 596.925 1309.353 2872.063 6299.863 Sildenafil 0.2mg/ml Heating 5 15 30 40 0 5 10 15 20 25 30 35 40 0.01 0.022 0.048 0.106 0.231 0.508 1.114 2.443 5.359 11.755 25.785 56.56 124.064 272.134 596.925 1309.353 2872.063 6299.863 Sildenafil 0.2mg/ml Cooling Graphs 1-6: These graphs are the baseline results of the heating and cooling behaviours of ELP L40 and Sildenafil. Size (nm) Size (nm) Size (nm) Size (nm) Size (nm) Size (nm) Volume (%) Volume (%) Volume (%) Volume (%) Volume (%) Volume (%) 5 15 30 40 0 10 20 30 40 50 0.01 0.022 0.048 0.106 0.231 0.508 1.114 2.443 5.359 11.755 25.785 56.56 124.064 272.134 596.925 1309.353 2872.063 6299.863 0.1mg/ml ELP L40 with Sildenafil Heating Graph 1 Graph 5 Graph 6 Graph 3 Graph 4 Graph 2 5 15 30 40 0 10 20 30 40 50 0.01 0.023 0.053 0.121 0.278 0.64 1.47 3.376 7.756 17.817 40.93 94.025 215.997 496.195 1139.872 2618.546 6015.396 0.1mg/ml ELP L40 with Sildenafil Cooling Graph 7 Graph 8 Size (nm) Size (nm) Volume (%) Volume (%) Graphs 7-10: These graphs are the result of ELP combined with the Sildenafil at two different concentrations of ELP. 5 20 35 50 0 10 20 30 40 0.01 0.022 0.048 0.106 0.231 0.508 1.114 2.443 5.359 11.755 25.785 56.56 124.064 272.134 596.925 1309.353 2872.063 6299.863 ELP L40 0.5mg/ml Heating The assembly behaviours of the 0.1mg/ml ELP L40 combined with the sildenafil solution varied from that of the assembly behaviours of just the ELP. The disassembly behaviours of the same ELP concentrations with sildenafil correlated with the ELP only solution, though the size of the ELP with the drug was larger and that might imply that the drug was loaded inside ELP particles. Similarly, the assembly behaviours of the 0.5mg/ml ELP L40 combined with the sildenafil solution related to the results of just the ELP though the size of the particles containing the drugs were much larger. The disassembly of the ELP with the sildenafil also correlated with that of the ELP only solution, though the particles were almost twice as large. The next step in this research is to determine quantitatively how much drug is loaded into ELP nanoparticles, and then evaluate the drug release profile from ELP nanoparticles/ 5 15 30 40 0 10 20 30 40 50 0.01 0.021 0.044 0.092 0.192 0.403 0.844 1.768 3.703 7.756 16.244 34.023 71.26 149.25 312.596 654.717 1371.272 2872.063 6015.396 0.5mg/ml ELP L40 with Sildenafil Heating Size (nm) Volume (%) Graph 9 Acknowledgements 5 15 30 40 0 10 20 30 40 50 0.01 0.021 0.044 0.092 0.192 0.403 0.844 1.768 3.703 7.756 16.244 34.023 71.26 149.25 312.596 654.717 1371.272 2872.063 6015.396 0.5mg/ml ELP L40 with Sildenafil Cooling Size (nm) Volume (%) Graph 10
Transcript
Page 1: Evaluation of Assembly and Disassembly Behaviour of Drug … · fluctuations as found in the Zetasizer Nano Series User Manual (Malvern Instruments LTD., 2003, 2004.) Figure 2: An

Introduction

Methods and Materials• ELPs aliquots are kept frozen at -80C and once thawed they need to stay in

ice to make sure that they do not undergo preliminary Tt, to ensure the mostaccurate results.

• Both ELP stock solution and the drug solution, in this case Sildenafil (a wellknown vasodilator), are individually combined with 1xPBS buffer todetermine the baseline assembly and disassembly behaviour of both the ELPand the sildenafil individually.

• ELP is then combined with the sildenafil and then diluted into the 1xPBS tocreate a solution to test the assembly and disassembly of the drug-loadednanoparticles.

• A solution is then placed into the dynamic light scattering machine (DLS),and the intensity of the light scattering is measured, which is then used toderive volume. Figure 2 shows the special DLS cuvette.

• The DLS machine (Figure 3) measures Brownian Motion, the constantmovement of particles due to collisions with other particles and liquids, todetermine the size and therefore intensity of the particles.

Results

• Thank you to Dr. Larry Unsworth, Abdullah Alshememry, Scott Elgersma, and all the members of Dr. Unsworth’s team for all your help within the lab throughout this program.

• A special thank you to NSERC Promo Science for the funding for my research this summer.

• Thank you to the WISEST Program for granting me this opportunity.

• My lab partners, Rebecca Probst and Gabrielle Smith for their help and support throughout this experience.

Evaluation of Assembly and Disassembly Behaviour of Drug-Loaded Peptide Nanoparticles

Mackenzie Fix, Abdullah Alshememry, Larry D. UnsworthDepartment of Chemical and Material Engineering, University of Alberta

National Institute for Nanotechnology, Edmonton, Alberta

Conclusions

Elastin-Like Polypeptides (ELPs) are repetitiveartificial polypeptides. The most common of ELP is in theform (VPGXG)n where X is a guest residue, and n is thenumber of pentapeptide repeats. ELPs in the form of(VPGXG)n exhibit an inverse temperature phase transition(Tt), meaning that below this temperature they aresoluble in aqueous solution, and above the Tt theyundergo an aqueous demixing phase transition resultingin aggregation of the ELP. The tunable properties and theTt of the ELP make them well-suited for drug deliverywithin the body. Figure 1 shows the reversible phasetransition behavior of ELPs.

Literature Cited • MacEwan, S. R. and Chilkoti, A. (2010), Elastin-like polypeptides: Biomedical applications of tunable biopolymers.

Biopolymers, 94: 60–77. doi:10.1002/bip.21327

• Bahniuk MS, Alshememry A, Unsworth LD. High yield expression of short chain elastin-like polypeptides. Biotechniques. 2016

• Malvern Instruments LTD. (2003, 2004). Zetasizer Nano Series User Manual. Retrieved from http://www.biophysics.bioc.cam.ac.uk/files/Zetasizer_Nano_user_manual_Man0317-1.1.pdf

Figure 3: An image of the

DLS instrument used in

the lab.

DLS Instrument Theory• Brownian motion is the movement of particles due to random collisions with

the liquid that surrounds the particle, therefore the particles are always moving.

• An important part of Brownian motion for DLS is that small particles move quickly while large particles move slowly.

Figure 4: An image of scattered light

exhibiting bright and dark area

fluctuations as found in the Zetasizer

Nano Series User Manual (Malvern

Instruments LTD., 2003, 2004.)

Figure 2: An image of

the special cuvette

carrying the mixture of

ELP and Sildenafil

Figure 1: An image of the

reversible phase transition behavior of ELPs

5

15

30

400

5

10

15

20

250

.01

0.0

22

0.0

48

0.1

06

0.2

31

0.5

08

1.1

14

2.4

43

5.3

59

11

.75

5

25

.78

5

56

.56

12

4.0

64

27

2.1

34

59

6.9

25

13

09

.35

3

28

72

.06

3

62

99

.86

3

ELP L40 0.1mg/ml Heating

5

15

30

400

5

10

15

20

25

30

0.0

1

0.0

21

0.0

44

0.0

92

0.1

92

0.4

03

0.8

44

1.7

68

3.7

03

7.7

56

16

.24

4

34

.02

3

71

.26

14

9.2

5

31

2.5

96

65

4.7

17

13

71

.27

2

28

72

.06

3

60

15

.39

6

ELP L40 0.1mg/ml Cooling

• Due to the movement of the particles, constructive and destructive phase addition of scattered light will lead to dark and bright area fluctuation (Figure 4), therefore it is said that the intensity at any particular point fluctuates.

• These fluctuations and the idea that large particles will lead to slow fluctuations and small particles will have quick fluctuations is what the DLS machine uses to calculate a size distribution.

5

15

30

400

10

20

30

40

50

0.0

1

0.0

2

0.0

4

0.0

8

0.1

6

0.3

2

0.6

4

1.2

79

2.5

59

5.1

17

10

.23

4

20

.46

6

40

.93

81

.85

5

16

3.6

99

32

7.3

79

65

4.7

17

13

09

.35

3

26

18

.54

6

52

36

.77

1

ELP L40 0.5mg/ml Cooling

5

15

30

400

5

10

15

20

25

30

35

40

0.0

1

0.0

22

0.0

48

0.1

06

0.2

31

0.5

08

1.1

14

2.4

43

5.3

59

11

.75

5

25

.78

5

56

.56

12

4.0

64

27

2.1

34

59

6.9

25

13

09

.35

3

28

72

.06

3

62

99

.86

3

Sildenafil 0.2mg/ml Heating

5

15

30

400

5

10

15

20

25

30

35

40

0.0

1

0.0

22

0.0

48

0.1

06

0.2

31

0.5

08

1.1

14

2.4

43

5.3

59

11

.75

5

25

.78

5

56

.56

12

4.0

64

27

2.1

34

59

6.9

25

13

09

.35

3

28

72

.06

3

62

99

.86

3

Sildenafil 0.2mg/ml Cooling

Graphs 1-6: These graphs are the baseline results of the heating and cooling behaviours

of ELP L40 and Sildenafil.

Size (nm)

Size (nm)

Size (nm)

Size (nm)

Size (nm)

Size (nm)

Volu

me (

%)

Volu

me (

%)

Volu

me (

%)

Volu

me (

%)

Volu

me (

%)

Volu

me (

%)

5

15

30

400

10

20

30

40

50

0.0

1

0.0

22

0.0

48

0.1

06

0.2

31

0.5

08

1.1

14

2.4

43

5.3

59

11

.75

5

25

.78

5

56

.56

12

4.0

64

27

2.1

34

59

6.9

25

13

09

.35

3

28

72

.06

3

62

99

.86

3

0.1mg/ml ELP L40 with Sildenafil Heating

Graph 1

Graph 5 Graph 6

Graph 3 Graph 4

Graph 2

5

15

30

400

10

20

30

40

50

0.0

1

0.0

23

0.0

53

0.1

21

0.2

78

0.6

4

1.4

7

3.3

76

7.7

56

17

.81

7

40

.93

94

.02

5

21

5.9

97

49

6.1

95

11

39

.87

2

26

18

.54

6

60

15

.39

6

0.1mg/ml ELP L40 with Sildenafil CoolingGraph 7 Graph 8

Size (nm)Size (nm)

Volu

me (

%)

Volu

me (

%)

Graphs 7-10: These graphs are the result of ELP combined with the Sildenafil at two

different concentrations of ELP.

5

20

35

50

0

10

20

30

40

0.0

1

0.0

22

0.0

48

0.1

06

0.2

31

0.5

08

1.1

14

2.4

43

5.3

59

11

.75

5

25

.78

5

56

.56

12

4.0

64

27

2.1

34

59

6.9

25

13

09

.35

3

28

72

.06

3

62

99

.86

3ELP L40 0.5mg/ml Heating

• The assembly behaviours of the 0.1mg/ml ELP L40 combined with the sildenafil solution varied from that of the assembly behaviours of just the ELP. The disassembly behaviours of the same ELP concentrations with sildenafil correlated with the ELP only solution, though the size of the ELP with the drug was larger and that might imply that the drug was loaded inside ELP particles.

• Similarly, the assembly behaviours of the 0.5mg/ml ELP L40 combined with the sildenafil solution related to the results of just the ELP though the size of the particles containing the drugs were much larger. The disassembly of the ELP with the sildenafil also correlated with that of the ELP only solution, though the particles were almost twice as large.

• The next step in this research is to determine quantitatively how much drug is loaded into ELP nanoparticles, and then evaluate the drug release profile from ELP nanoparticles/

5

15

30

400

10

20

30

40

50

0.0

1

0.0

21

0.0

44

0.0

92

0.1

92

0.4

03

0.8

44

1.7

68

3.7

03

7.7

56

16

.24

4

34

.02

3

71

.26

14

9.2

5

31

2.5

96

65

4.7

17

13

71

.27

2

28

72

.06

3

60

15

.39

6

0.5mg/ml ELP L40 with Sildenafil Heating

Size (nm)

Volu

me (

%)

Graph 9

Acknowledgements

5

15

30

400

10

20

30

40

50

0.0

1

0.0

21

0.0

44

0.0

92

0.1

92

0.4

03

0.8

44

1.7

68

3.7

03

7.7

56

16

.24

4

34

.02

3

71

.26

14

9.2

5

31

2.5

96

65

4.7

17

13

71

.27

2

28

72

.06

3

60

15

.39

6

0.5mg/ml ELP L40 with Sildenafil Cooling

Size (nm)

Volu

me (

%)

Graph 10

Recommended