Description:
First available NET ZERO capable cooling tower. With the use of EC fans and solar power panels EVAPCO's new SUN tower cooling tower can meet the demand of HVAC cooling and a minimal to zero financial cost. Other uses of the SUN tower are value engineering geothermal projects, assisting in overheated geothermal fields, and complimenting hybrid designs.
Popular Tags:
29
1 Introducing… The SUN Cooling Tower!
Transcript
Page 1: EVAPCO NET ZERO Cooling Tower

1

Introducing…

The SUN Cooling Tower!

Page 2: EVAPCO NET ZERO Cooling Tower

2

SUN Cooling Tower

The World’s First Cooling Tower Capable of

Energy Consumption!

Net Zero

Page 3: EVAPCO NET ZERO Cooling Tower

3

SUN Cooling Tower

NET ZERO Capability

Average North American Solar Exposure

Surplus Energy Generated Off Peak

Supplemental Utility Power at Full Load

Variable Load Profile, e.g. Commercial Building

Page 4: EVAPCO NET ZERO Cooling Tower

4

ALWAYS Reduces AnnualPower Requirement

SUN Cooling Tower

Page 5: EVAPCO NET ZERO Cooling Tower

5

SUN Cooling Tower

Innovative SUN Package

Strategically Located Solar Panel Array

Maximum Airflow

Factory Supplied Solar Power and Capacity Controls

Page 6: EVAPCO NET ZERO Cooling Tower

6

SUN Cooling Tower

Why Consider The SUN?

Desire to Earn LEED Points

Capitalize on Federal and State Tax Credits

Requires Limited Additional Roof Plan Area

Opportunity for NET ZERO Fan Energy Consumption

Page 7: EVAPCO NET ZERO Cooling Tower

7

SUN Cooling Tower

Solar Panel Technology

High Density Panel Array Model A: 3,000 Total Watts Model B: 2,250 Total Watts

Each Panel is Equipped With an Inverter to Output AC Power

Polycrystalline Solar Cells

Page 8: EVAPCO NET ZERO Cooling Tower

8

SUN Cooling Tower

Electronically Commutated “EC” Fan Motors

Eliminates VFD and Starter Requirements

Speed Controlled via 0-10 Volt or Modbus Signal Integral Speed Control Within Motor

High Efficiency Direct Drive Motors

Page 9: EVAPCO NET ZERO Cooling Tower

9

SUN Cooling Tower

Fan Wall Technology

Minimizes Static Pressure Through Solar Panel Array

Maximum Solar Panel Density Per Cooling Tower Plan Area

Page 10: EVAPCO NET ZERO Cooling Tower

10

SUN Cooling Tower

Warranty

5 Year Solar Panel Parts Warranty

Complete 5 Year Unit Warranty With the Addition of any Stainless Steel Option

5 Year Motor and Fan Warranty

Page 11: EVAPCO NET ZERO Cooling Tower

11

SUN Cooling Tower

SUN Control Panel

Digital Display of Instant Solar Power Generated and Fan Power Draw

Ethernet Controller for Remote Monitoring and Trending of Solar Panel Production

Page 12: EVAPCO NET ZERO Cooling Tower

12

SUN Cooling Tower

Integral Capacity Control

Local and Remote (BAS) Control Functionality

0-10 Volt or Modbus Remote (BAS) Control Options

Thermostat and 0-10 Volt Transmitter Provide Local Temperature Set Point Capacity Control

Page 13: EVAPCO NET ZERO Cooling Tower

13

SUN Cooling Tower

SUN Wiring

Factory Wired Components Fan Motors Solar Panel Inverters (Field Connection Required After Installation) Transformer

Single Point Power

Field Wiring Fan Disconnect to SUN Panel Solar Disconnect to SUN Panel Modbus Connection (as Required)

Page 14: EVAPCO NET ZERO Cooling Tower

14

Page 15: EVAPCO NET ZERO Cooling Tower

15

SUN Cooling Tower

Electrical Flow

(1) Solar Energy is Captured by the Solar Panels and Converted to DC Power

(2) The DC Power is Converted to 208/3/60 AC Through an Inverter on the Back of Each Solar Panel(3) The 208/3/60 AC Power is Stepped Up Through a Transformer to Match the Local Utility, e.g. 460/3/60

(1)

(3)(2)

Page 16: EVAPCO NET ZERO Cooling Tower

16

Electrical Flow

SUN Cooling Tower

(1) The Power is Wired to the SUN Control Panel, (2) Where it Feeds a Fan Disconnect and Ultimately the Fan Motors

(3) If the Solar Power Generated Does Not Meet the Fan Power Draw, it is Supplemented by the Utility Power

(4) If the Solar Power Generated Exceeds the Fan Power Draw, the Excess is Directed Back Towards the Facility for Use Elsewhere

(1)

(2)

(3)(4)

Page 17: EVAPCO NET ZERO Cooling Tower

17

SUN Cooling TowerElectrical Flow Summary

Page 18: EVAPCO NET ZERO Cooling Tower

18

SUN Cooling Tower

Internet Interface

Page 19: EVAPCO NET ZERO Cooling Tower

19

SUN Cooling Tower

Internet Interface

Daily and Monthly Reports Peak Power Production Individual Panel Functionality

Page 20: EVAPCO NET ZERO Cooling Tower

20

SUN Cooling Tower

LEED® Green Building Rating System

Energy and Atmosphere Credit: Optimize Energy Performance

Energy and Atmosphere Credit: Renewable Energy Production

Innovation in Design Credit

Page 21: EVAPCO NET ZERO Cooling Tower

21

SUN Cooling Tower

30% Federal Credit on Solar Components Solar Panel Array SUN Control Panel Supports and Solar Wiring

Additional Local State Tax Deductions

Tax Credits

Page 22: EVAPCO NET ZERO Cooling Tower

22

SUN Cooling Tower

SUN-19-611

Orientation

Layout

S

Page 23: EVAPCO NET ZERO Cooling Tower

23

SUN Cooling Tower

SUN-112-812L

Orientation

Layout

S

Page 24: EVAPCO NET ZERO Cooling Tower

24

SUN Cooling Tower

SUN Installation

Three Section Shipment

Fan

Casing

Basin

Page 25: EVAPCO NET ZERO Cooling Tower

25

SUN Cooling Tower

Solar Package Assembly

Most Solar Brackets Arrive Factory Mounted

Outer Brackets Require Field Assembly (Shipping Limitation)

Page 26: EVAPCO NET ZERO Cooling Tower

26

Solar Package Assembly

SUN Cooling Tower

Mounting of Solar Panels

Connecting Copper Grounding Wire

Evapco Factory Assistance

Connecting Inverters

Page 27: EVAPCO NET ZERO Cooling Tower

27

Solar Package Assembly

Rigging Fan to Casing Section

SUN Cooling Tower

Page 28: EVAPCO NET ZERO Cooling Tower

28

Reduction of Geothermal Field Sizing the geothermal field for heating and light cooling loads greatly reduces initial cost

SUN TOWER reduces geothermal field by 60% or more

Save up to $500,000 initial cost on a 300 ton geothermal system

Page 29: EVAPCO NET ZERO Cooling Tower

29

SUN Cooling Tower

SUN Summary:

Net Zero Energy Usage

Complete Factory Mounted Controls

Annual State Tax Credits

Sustainability

LEED® Opportunities


Recommended