Signia™ Stapling System
EVERY INDUSTRY HAS SMART INNOVATION. IN HEALTHCARE, IT TAKES A DIFFERENT KIND OF SMART.
PRECISE CONTROL. CONSISTENT STAPLE LINES.2,3 SMART STAPLING, DEFINED.
SMART IS DELIVERING REAL-TIME FEEDBACKThe Signia™ system uses technology to:
■ Communicate the zone it’s firing in—from Zone 1 at regular speed, to Zone 3 at slowest speed4
■ Deliver consistent staple lines2,3
■ Provide both visible and audible feedback
■ Support clinical decision making by providing force-sensing feedback1,5
SMART IS TRI-STAPLE™ TECHNOLOGYThis technology has been providing customers with graduated compression profile, which delivers:
■ Less stress on tissue during compression and clamping8
■ Outstanding performance in variable tissue thickness
■ Greater perfusion into the staple line versus uniform staple closure9
v
SMART IS ADAPTING TO EVERY TISSUE CHALLENGEBecause tissue varies throughout the body and between patients, the Signia™ stapling system uses Adaptive Firing™ technology to:
■ Measure force and provide feedback when clamping tissue1,2,3
■ Set firing speed based on clamp force measurement4
■ Continuously measure force during firing and slow firing speed based on those measurements4
SMART IS PRECISION AND MANEUVERABILITYThe Signia™ system is a fully powered single-handed stapler with powered articulation, rotation, clamping and firing. It:
■ Provides greater precision and maneuverability† 6,7
■ Reduces unwanted motion when manipulating, clamping and firing through tissue† 6,7
† As compared to manual devices and/or EES Echelon Flex™*
SMART IS BEING REUSABLEInstead of using batteries that must be disposed of after a single procedure, the Signia™ system:
■ Is reusable for up to 300 procedures
■ Uses a lithium rechargeable battery4
■ Employs a universal reload platform
medtronic.com
Tel: 800-272-8772Fax: 888-636-1002medtronic.com/covidien
© 2018 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic. ™* Third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company. 07/2018‑US180724 ‑ [WF# 2659929]
REFERENCES
† Pre‑clinical results may not correlate with clinical performance in humans.
1. Based on internal test report #RE00024826, Signia™ stapling system summative usability report, January 2016.
2. Based on internal test report #R2146‑151‑0, Powered Stapling Firing Speed DOE Analysis and ASA Parameters, 2015.
3. Based on internal test report #R2146-173-0, ASA Verification Testing with Slow Speed Force Limit Evaluation, 2015.
4. Based on PT00002451 Signia™ Stapler User Manual, Page 13.
5. Based on Engineering Report #PCG022. Comparison of the iDrive™‑S, iDrive™‑F, Ethicon 60 and universal 60 Staple Formation in Thick Tissue Stomach Firings;January, 2016.
6. R0033554 iDrive™ Ultra PCR Summary Report; November, 2012.
7. RE00022065 S.Drew T.Terk, P.Donald UCONN Biodynamics Final Report on Results focusing on biomechanical exposure related to laparoscopic stapler use; 2012.
8. Based on internal test report #PCG-007. When compared to Echelon Flex™* green reloads as part of an analysis comparing different stapler designs and their performance and impact on tissues under compression using two-dimensional finite element analysis. Sept. 2, 2011.
9. Based on internal engineering report #2128‑002‑2, Final analysis of staple line vascularity using MicroCT. 2015.
The Signia™ stapling system leaves you in control – while providing real-time information and consistent staple lines – across patients, tissue types and procedures.
To try the Signia™ system in your next procedure contact your local Medtronic Sales Representative or visit medtronic.com