    Evolution SeriesUser Manual

    Maintenance

    B4065 Rev. D

    This manual is the property of Nera Networks AS. No parts of the manual may be copied, rewritten or distributed to third parties without the

    written permission from Nera Networks AS.

    In addition to the WEB edition

    the manual is available in

    paper format

  • 8/10/2019 Evolution Maintenance

    2/26

    The manual is divided in 5 main parts:

    General

    Installation

    Operation

    Maintenance

    Appendices

    This part gives a general overview of the Evolution Series equipment

    Gives the details on how to install the equipment

    Describes how to operate the system with emphasis on the Evolution Series Manager

    Gives details on maintenance of the equipment

    A collection of frequency plans, alarm lists, technical specifications etc.

  • 8/10/2019 Evolution Maintenance

    3/26

    Table of Contents

    General

    Installation

    Operation

    MaintenanceFault FindingBlock Schematic Fault Finding

    Front Panel Alarm diagnostics

    Unit ReplacementIFU Replacement

    IFU Units

    SU Replacement

    Appendi ces

    Click on the to expand

    the menu

    Home

  • 8/10/2019 Evolution Maintenance

    4/26

    Fault Finding

    These procedures describe the most common fault-situations.

    It is important to find the defective unit in order to minimize time consumption for fault finding and traffic downtime. This is normally done based on alarms, meter readings and looping fromEvolution Manager.It is impossible to make a block schematic that covers all possible faults, therefore the following block-diagrams only cover the most common problems.

    Note! The fault-finding needs to be performed by skilled engineers.

    It is also important to have system-knowledge and skills in the use of Evolution Manager tools like looping-facilities, alarm and performance logs.Potentional problems are also related to installation of IFU-ODU cables and connectors. Water penetration, lightening, or mechanical stress, may give IFU-ODU cable-problems. Sometimes it isdifficult to find the reason for the problem since a faulty cable, connector, power supply and different ODU-faults are giving exactly the same alarm-picture in Evolution Manager. Normally when the

    link connection is lost, the alarm-information from the remote station is also lost.Check if the IFU-ODU cable is shorted or open, by measuring the resistance on the IFU-side of the cable. It is also recommended to measure -48 V on the IFU connector as well as on the ODUside of the cable.Whenever unscrewing the connector on the ODU, make sure that it is always reconnected properly and protected from water penetration, by using the rubber sleeve or vulcanizing tape.

    Block Schematic Fault Finding

  • 8/10/2019 Evolution Maintenance

    5/26

    Diagram 1, Fault Finding by Looping

    Block Schematic Fault Finding

  • 8/10/2019 Evolution Maintenance

    6/26

    Diagram 2, RF problems

  • 8/10/2019 Evolution Maintenance

    7/26

    Diagram 3, Rx level problems

  • 8/10/2019 Evolution Maintenance

    8/26

    Diagram 4, Nominal Rx level problems

  • 8/10/2019 Evolution Maintenance

    9/26

    A red LED indicates alarm status on the unit. A blinking red LED indicates that the speciffic unit is placed in wrong slot according to"Unit Housekeeping".

    Complete LED description for each unit is described in sectionGeneral/System Overview/IFU Overview.The SU LED will in addition act as a system alarm. If one of the AUX, Plug-in, RIU or FAN units have alarm, the SU will also indicate the alarm situation.The following alarm severities will give alarm indication on the front panel:

    MINOR

    MAJOR

    CRITICALFor a complete alarm lists seeAppendices/Alarm Lists

    Example1

    Example2

    Example3

    Alarm Name Descript ion Solut ion

    SUBUS LINK Ethernet Link alarm between SU and IFU

    Basic Frame

    Remove and re-insert SU in IFU Basic

    Frame. If alarm condition persists - replace

    SU or IFU Basic Frame

    CONFIGURATION FAILURE Configuration of SU failed Remove and re-insert SU in IFU Basic

    Frame. If alarm condition persists -replace

    SU unit

    The following alarms areEthernet alarms, onlyrelevant when the NE is

    configured in IP mode

    ------------------------------------------------- ---------------------------------------------------

    SU

    Front Panel Alarm Diagnostics

    This is a simple procedure based on Unit-front LED and alarm status.The alarm status can be monitored from theEvolution Manager, Fault page.No units in the Evolution Series equipment is intended for field repair. A faulty unit is to be replaced with a new unit according to the requirements in the"Unit replacement"chapter.

    Note! Check all cable connections and that all units are completely seated in the IFU Basic Frame housing before further troubleshooting is performed.

  • 8/10/2019 Evolution Maintenance

    10/26

    HP-TIM / TIM-P SDH Higher order Path Trace Identifier

    Mismatch (VC-4) / SONET Higher order Path

    Trace Identifier Mismatch (STS-3c SPE)

    Verify configuration of Trace Identifier on

    transmit and receive side. If conflict, verify

    VC-4 trail including cables and X-connections

    LINK LOSS Ethernet (ETH2 port on SU front) link loss Check Ethernet cable or peripheral

    equipment

    FORCED LINK LOSS Ethernet (ETH2 port on SU front) is forced

    down due to remote side link loss

    If no Radio Link alarms on either side of the

    hop - check ethernet cable or peripheral

    equipment on remote side of the hop

    LOC Signal from IFU Basic Frame to SU is

    squelched or defect

    If no other Radio Link alarms - replace SU or

    IFU Basic Frame

    OOF Out OF Frame from IFU Basic Frame to SU If no other Radio Link alarms - replace SU or

    IFU Basic Frame

    The following alarms are

    system alarms and do no tindicate a faulty SU:

    ------------------------------------------------- ---------------------------------------------------

    LOST CONTACT Communication between SU and IFU Basic

    Frame failed

    Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - unplug power cables

    on the current IFU Basic Frame and

    reconnect the cables. If alarm situation

    persists - replace IFU Basic Frame

    CONFIGURATION FAILURE Configuration of IFU Basic Frame failed Check for "SUBUS LINK" or"CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - unplug power cables

    on the current IFU Basic Frame and

    reconnect the cables. If alarm situation

    persists - replace IFU Basic Frame

    AIS-INSERT Signal from Line Interface Unit or SU to IFU

    Basic Frame squelched or defect (transmit

    direction, towards radio)

    Check alarms on corresponding LIUs and

    SU. Handle alarms on these units first. If no

    alarms on corresponding LIUs or SU -replace IFU Basic Frame

    RX FAILURE Signal from RIU to IFU Basic Frame

    squelched or defect (receive direction, from

    radio)

    Check alarms on corresponding RIUs. Handle

    alarms on these units first. If no alarms on

    corresponding RIUs - replace RIU or IFU

    Basic Frame

    LOF STM-1/STS3 Loss Of Frame This alarm will only occur in combination with

    other Radio Link Alarms. Handle the other

    alarms first. If alarm condition persists -

    change IFU Basic Frame

    RS-TIM / TIM-S Regenerator Section Trace Identifier

    Mismatch

    Verify configuration of Trace Identifier on

    transmit and receive side. If configurations

  • 8/10/2019 Evolution Maintenance

    11/26

    are matching - verify STM-1/STS-3(OC-3)

    trail including cables and X-connections See

    Evolution Manager IFU Basic Frame Path

    Trace

    PDH SYNCLOSS ALARM PDH Loss Of Frame This alarm will only occur in combination with

    other Radio Link Alarms. Handle the other

    alarms first. If alarm condition persists -change IFU Basic Frame

    RPS SET TX MUTE FAILED Setting of mute Tx signal on ODU failed This alarm will only occur in combination with

    other Radio Link Alarms. Handle the other

    alarms first. If alarm condition persists - report

    fault situation to Nera Networks

    RPS CHAN NOT ALIGNED RPS receive switch failure due to no

    alignment

    This alarm will only occur in combination with

    other Radio Link Alarms. Handle the other

    alarms first. If alarm condition persists - verify

    Radio Link Path delay difference between thechannels

  • 8/10/2019 Evolution Maintenance

    12/26

    EOW

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and EOW unit

    failed

    Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    EOW unit in IFU Basic Frame. If alarmcondition persists - replace unit

    CONFIGURATION FAILURE Configuration of EOW unit failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    EOW unit in IFU Basic Frame. If alarm

    condition persists - replace unit

    OHC LINK LOSS The internal packet channel has an error Remove and re-insert EOW unit in IFU Basic

    Frame. If alarm condition persists - replace

    unit or IFU Basic Frame

  • 8/10/2019 Evolution Maintenance

    13/26

    4x64kb/s

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and 64kb/s unit

    failed

    Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    4x64kb/s unit in IFU Basic Frame. If alarmcondition persists - replace unit

    CONFIGURATION FAILURE Configuration of 64kb/s unit failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    4x64kb/s unit in IFU Basic Frame. If alarm

    condition persists - replace unit

    OHC LINK LOSS The internal packet channel has an error Remove and re-insert 64kb/s unit in IFUBasic Frame. If alarm condition persists -

    replace unit or IFU Basic Frame

  • 8/10/2019 Evolution Maintenance

    14/26

    ACU

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and the ACU

    failed

    Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    ACU unit in IFU Basic Frame. If alarm

    condition persists - replace unit

    CONFIGURATION FAILURE Configuration of the ACU failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    ACU unit in IFU Basic Frame. If alarm

    condition persists - replace unit

    LIU Optical

  • 8/10/2019 Evolution Maintenance

    15/26

    LIU Optical

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and LIU failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unit

    CONFIGURATION FAILURE Configuration of LIU failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unit

    LOS Loss of input signal to LIU Check cables and cable connectors to

    peripheral device. If peripheral device and

    cable connectors are ok - replace unit

    LOF STM-1/STS-3/OC-3 Loss Of Frame Check cables and cable connectors toperipheral device. If peripheral device and

    cable connectors are ok - replace unit

    RS-TIM / TIM-S Regenerator Section Trace Identifier

    Mismatch

    Verify configuration of Trace Identifier on

    transmit and receive side. If configurations

    are matching - verify STM-1/STS-3(OC-3)

    trail including cables and X-connections. See

    Evolution Manager LIU Path Trace

    AIS INSERT AIS inserted towards Line Out Check other Radio Link alarms. Handle

    alarms on these units first. If no alarms -

    replace LIU or IFU Basic Frame

    Tx Laser Fault Transmit laser failed Replace Optical Line Interface Unit

  • 8/10/2019 Evolution Maintenance

    16/26

    LIU El

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and LIU failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unitCONFIGURATION FAILURE Configuration of LIU failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unit

    LOS Loss of input signal to LIU Check cables and cable connectors to

    peripheral device. If peripheral device and

    cable connectors are ok - replace unit

    LOF STM-1/STS-3/OC-3 Loss Of Frame Check cables and cable connectors to

    peripheral device. If peripheral device and

    cable connectors are ok - replace unit

    RS-TIM / TIM-S Regenerator Section Trace Identifier

    Mismatch

    Verify configuration of Trace Identifier on

    transmit and receive side. If configurations

    are matching - verify STM-1/STS-3(OC-3)

    trail including cables and X-connections. See

    Evolution Manager LIU Path Trace

    AIS INSERT AIS inserted towards Line Out Check other Radio Link alarms. Handle

    alarms on these units first. If no alarms -

    replace LIU or IFU Basic Frame

  • 8/10/2019 Evolution Maintenance

    17/26

    LIU 3xDS3/E3

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and LIU 3xDS3/

    E3 unit failed

    Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unit

    CONFIGURATION FAILURE Configuration of LIU 3xDS3/E3 unit failed Check for "SUBUS LINK" or"CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unit

    LOS 01...03 Loss of 3xDS3/E3 input signal Check cables and cable connectors to

    peripheral device. If peripheral device and

    cable connectors are ok - replace unit

  • 8/10/2019 Evolution Maintenance

    18/26

    LIU 25x E1

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and LIU 25xE1

    unit failed

    Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unit

    CONFIGURATION FAILURE Configuration of LIU 25xE1 unit failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    LIU in IFU Basic Frame. If alarm condition

    persists - replace unit

    LOS 01...25 Loss of E1 input signal Check cables and cable connectors to

    peripheral device. If peripheral device and

    cable connectors are ok - replace unit

    Gi bit Eth t

  • 8/10/2019 Evolution Maintenance

    19/26

    Gigabit Ethernet

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and Gigabit

    Ethernet unit failed

    Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    the Gigabit Ethernet unit in IFU Basic Frame.

    If alarm condition persists - replace unit

    CONFIGURATION FAILURE Configuration of Gigabit Ethernet unit failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    the Gigabit Ethernet unit in IFU Basic Frame.

    If alarm condition persists - replace unit

    VCG-[1..8] DOWN All members of VCG is down Check for other Radio Link alarms. If no other

    Radio Link alarms are present - verify VCGconfiguration on both sides of the connection

    VCG-[1..8] DEGRADED Some members of VCG is down Check for other Radio Link alarms. If no other

    Radio Link alarms are present - verify VCG

    configuration on both sides of the connection

    ETH LINK LOSS Traffic Ethernet link down Check Ethernet cable(s) or periferal

    equipment

    FORCED LINK LOSS Traffic Ethernet link is forced down due to

    remote link loss

    If no Radio Link alarms on either side of the

    hop - check ethernet cable or peripheralequipment on remote side of the hop

    DXC

  • 8/10/2019 Evolution Maintenance

    20/26

    DXC

    Al arm Name Descri pt io n Solut io n

    LOST CONTACT Communication between SU and DXC unit

    failed

    Remove and re-insert DXC unit in IFU Basic

    Frame. If alarm condition persists - replace

    unit

    CONFIGURATION FAILURE Configuration of DXC unit failed Check for "SUBUS LINK" or

    "CONFIGURATION FAILURE" alarms on the

    SU. Handle alarms on SU first. If these

    alarms are not present - remove and re-insert

    DXC in IFU Basic Frame. If alarm condition

    persists - replace unit

    OOF STM-1 / STS-3 / OC-3 Out Of Frame Remove and re-insert DXC unit in IFU Basic

    Frame. If alarm condition persists - unplug

    and reconnect power cable(s)

    LOC Loss Of Clock Remove and re-insert DXC unit in IFU Basic

    Frame. If alarm condition persists - unplug

    and reconnect power cable(s)

    RIU

  • 8/10/2019 Evolution Maintenance

    21/26

    Alarm Name Description Solut ion

    LOST CONTACT Communication between SU andRIU failed

    Check for "SUBUS LINK" or"CONFIGURATION FAILURE"alarms on the SU. Handle alarms onSU first. If these alarms are notpresent - remove and re-insert RIU in

    IFU Basic Frame. If alarm conditionpersists - replace unit

    CONFIGURATIONFAILURE

    Configuration of RIU failed Check for "SUBUS LINK" or"CONFIGURATION FAILURE"alarms on the SU. Handle alarms onSU first. If these alarms are notpresent - remove and re-insert RIU inIFU Basic Frame. If alarm condition

    persists - replace unit

    LBER Estimated Bit Error Rate is aboveconfigured threshold

    Check other Radio Link alarms -Handle these alarms first. If no otheralarms - check RF input level onODU connected to this RIU. If RFinput level ok - check antenna(re-adjust)and RF path

    HBER Estimated Bit Error Rate is aboveconfigured threshold Check other Radio Link alarms -Handle these alarms first. If no otheralarms - check RF input level onODU connected to this RIU. If RFinput level ok - check antenna(re-adjust)and RF path

    DEMOD SYNC LOSS Demodulator is out ofsynchronization

    Check other Radio Link alarms -Handle these alarms first. If no other

    alarms - check RF input level onODU connected to this RIU. If RFinput level ok - check antenna

    RIU

  • 8/10/2019 Evolution Maintenance

    22/26

    (re-adjust)and RF path

    ODU LOST CONTACT Communication from ODU to RIUfailed

    Disconnect and reconnect IFU-ODUcable. If alarm persists - checkcables and connectors and -48VDC

    to ODUTX FAILURE Missing signal from IFU Basic Frame Check if IFU Basic Frame has

    "CONFIGURATION FAILURE"alarm. If not - replace RIU or IFUBasic Frame

    ODU POWER FAILURE -48V to ODU is shut down Disconnect and reconnect IFU-ODUcable. If alarm persiste - checkIFU-ODU cable and connectors forshort circuits. If cable ok, there is adefect in either RIU or ODU - replaceRIU or ODU

    EXT AGC AT MAX Signal power level from ODU to RIUis below limit

    Check IFU-ODU cable for excessiveloss (may be due too cable length orcable quality). If cable ok, there is adefect in RIU or ODU - replace RIU

    or ODUADC OVERRANGE Signal power level from ODU to RIU

    is above limitDefect RIU or ODU - replace RIU orODU

    XPIC SYNC LOSS Signalling between RIUs for XPIChas failed

    Missing signal from the other RIU onthe other polarization. Remove andreinsert both RIUs. If alarm situationpersiste - replace one RIU at thetime (start with the RIU with alarm). If

    alarm situation persists - replase IFUBasic Frame

    ODU

  • 8/10/2019 Evolution Maintenance

    23/26

    Al arm Name Descri pt io n Solut io n

    NEED CONFIGURATION ODU configuration is missing Unplug and reconnect power cable. If alarm

    condition persists - replace ODU

    LOST CONTACT Communication between SU and ODU failed Check cable and connectors. Check surge

    arrestors if mounted.

    TX LO Transmitter local oscillator failure Unplug and reconnect power cable. If alarmcondition persists - replace ODU

    RX LO Receiver local oscillator failure Unplug and reconnect powercable. If alarmcondition persists - replace ODU

    CABLE LOF Signal from RIU not received properly in the

    ODU

    Check IFU-ODU cable for excessive loss

    (may be due too cable length or cable quality).

    If cable ok, there is a defect in RIU or ODU -

    replace RIU or ODU

    TRANSMITTER FAILURE Transmitter power amplifier is overheated Check airflow around the ODU. If airflow isOK and alarm status persists - change ODU

    RF OUTPUT TOO LOW Measured RF Output level is below setting Disconnect and reconnect power cable. If

    alarm condition persists - replace ODU

    ATPC LOOP BROKEN ATPC feedback signal from remote receiver

    failed

    Normally due to other Radio Link alarm. If no

    other Radio Link alarms - disconnect and

    reconnect power cable. If alarm condition

    persists - replace ODU

    RF INPUT LOS RF input signal level is below critical limit May be due to weather/atmosphericalconditions, orantennas need re-adjustment

    POWER SUPPLY FAILURE One or more of the secondary (internal)

    powersources out of order

    Check voltage level on ODU connector (-40.5

    to -57 VDC). If voltage level within spec. -

    replace ODU

    FAN

  • 8/10/2019 Evolution Maintenance

    24/26

    Al arm Name Descri pt io n Solut io n

    FAN ALARM Combined alarm for the 3 fans on the Fan

    unit. Fan speed is too low

    Change FAN Unit - If alarm condition persists

    - change IFU Basic Frame

  • 8/10/2019 Evolution Maintenance

    25/26

    Unit Replacement

    The new unit must have exactly the same unit code (Code:) as the unit to be replaced.The unit revision (Rev:) is on the format "R1A" (revision 1A). The new unit must have the same or higher digit (1) on the revision tag to be compatible with the one to be replaced. The letter (A) is notsignificant for interchangeability. See a typical label below:

    The Supervisory Unit stores a copy of the configuration and SW for the different units. If a unit is replaced, the configuration will be automatically downloaded from the Supervisory Unit to the newunit.

    Note! This equipment contains components which are sensitive to "ESD" (Electro Static Discharge). It is therefore essential that wheneverdisassembling the equipment and/or handling PC

    boards, special precautions to avoid ESD are made. These precautions include personnel grounding, grounding of work bench, grounding of tools and instruments as well as transport and storagein special antistatic bags and boxes.

    IFU Basic Frame Replacement

    Note! When a complete IFU Basic Frame is replaced, the traffic through this IFU will be broken.

    1. Unplug the power connector(s) on the RIU unit(s).2. Disconnect all cables on the IFU front carefully. Mark all cables to ensure that the cables can be reconnected to the correct terminals on the new IFU.3. IF the IFU ismounted in an equipment rack, unscrew the IFU from the rack (four screws).4. Pull the IFU out carefully.5. Remove all plug-in units except the Fan unit (the FAN unit is part of the IFU Basic Frame).

    Replacement

    1. Replace the plug-in units in the spare IFU Basic Frame.2. Insert the new IFU in the Equipment rack (if rack mounted) carefully.

    Note! If the IFU is part of a system with more than 2 channels, make sure that the plate, covering the IFU rear connectors, is removed and slide the IFU to enter the corresponding

    connectors in the IFU shelf, without the use of excessive force.3. Fasten the four screws.

    4. Reconnect the front cables.5. Reconnect the power cable(s).

    IFU Units

    Note! If the Radio system is protected (1+1, 2+1 etc.), manually switch the protection switching to the functioning channel(see Configuration/RPS/Manual Switch)before a RIU carrying

    traffick, is removed from the IFU. Otherwise the traffic can be broken.

    For SU replacement, see paragraphSU Replacement.

  • 8/10/2019 Evolution Maintenance

    26/26

    1. Unplug all cables on the unit to be replaced.2. Unscrew the two "finger" screws that secure the unit to the IFU. A screwdriver may be used if necessary to unscrew the screws.3. Remove the unit carefully from the IFU by pulling the screws.

    Replacement

    1. Insert the new unit carefully. Ensure that the unit enters the guides inside the IFU and gently press the unit to enter the internal connectors without the use of excessive force.2. Fasten the two screws with your fingers. Do not use a screwdriver.3. Reconnect all cables.

    SU Replacement

    In addition to the steps in the paragraph above, it is important that the correct system configuration is reloaded from a backup file when the SU is replaced by a spare unit.(See Operation Section;Evolution Manager/Feature Description/Configuration/Backup)


Recommended