32
A A SEMINAR SEMINAR PRESENTATION PRESENTATION ON ON “ELECTRONIC SWITCHING SYSTEM “ELECTRONIC SWITCHING SYSTEM DIGITAL” DIGITAL” PRESENTED BY PRESENTED BY :- :- ASHUTOSH MALAWAT ASHUTOSH MALAWAT ELECTRONICS AND COMM. ELECTRONICS AND COMM. B.TECH ,FINAL YEAR B.TECH ,FINAL YEAR
Transcript
Page 1: EWSD SYSTEM PPT

AA SEMINAR SEMINAR PRESENTATION PRESENTATION ON ON “ELECTRONIC SWITCHING SYSTEM “ELECTRONIC SWITCHING SYSTEM DIGITAL” DIGITAL”

PRESENTED BYPRESENTED BY:-:-

ASHUTOSH MALAWATASHUTOSH MALAWAT

ELECTRONICS AND COMM.ELECTRONICS AND COMM.

B.TECH ,FINAL YEARB.TECH ,FINAL YEAR

Page 2: EWSD SYSTEM PPT

EWSD INTRODUCTION

EWSD is the abbreviated form of German equivalent of Electronic Switching System Digital (Electronische Wheler Systeme Digitale).

EWSD Digital switching system has been designed and manufactured by M/s Siemens, Germany.

Page 3: EWSD SYSTEM PPT

SYSTEM FEATURES

EWSD system can withstand a BHCA of 4 million with CP-113C in case of EWSD Powermode (two million in case of EWSD Classic).

It can work as local cum transit exchange and supports CCS No.7, ISDN and IN and V5.X features.

Page 4: EWSD SYSTEM PPT

SYSTEM ARCHITECTURE

Digital line unit (DLU)

Line/Trunk Group (LTG)

Switching Network (SN)

Coordination Processor (CP)

Common Channel Signalling Network Control (CCNC) Unit or Signalling System Network Control (SSNC)

Page 5: EWSD SYSTEM PPT

.

DLU

DLUCC

LTG

GP

LTG

GP

Common channel signalling/ Signalling System Network Control

CCNC/SSNC

Access

Coordination

CPSYPSYPC

MBMBC

CCG

EM

OMT SGC

Switching Network

Distributed controls in EWSD

.

Page 6: EWSD SYSTEM PPT

DLU(DIGITAL LINE UNIT)

It is a functional unit on which subscriber lines are terminated.

DLUs are connected to EWSD sub-systems via a uniform interface standardized by CCITT i.e. PDC.

One DLU is connected to two different LTGs for the reasons of security via two 4 Mbps links.

Total 124 channels are available between a DLU out of which the two LTGs signalling information is carried in TS16 of PDC0 and PDC2.

Page 7: EWSD SYSTEM PPT

PDC3 without ccs

PDC2 with ccs

PDC1 without ccs

PDC0 with ccs

Subscriber lines and PBX lines for small and medium-sized PBXs

Remote application

Local application

4Mbps

SNLTG

LTG

CP

4 MbpsDLU

DLU

Subscriber lines and PBX lines for small and medium-sized PBXs

CCITT standard interface G.703

Remote application :

in same directory number area,

in another directory number area,

as extension to conventional exchange.

Applications and connection of Digital Line Unit

Page 8: EWSD SYSTEM PPT

.

One DLU can carry traffic of 100 Erlangs.

For emergency service DLU-controller (DLUC) always contain up-to-date subscribers data.

Stand Alone Service Controller card (SASCE) is provided in each R-DLU for switching calls in emergency cases .

All DLUs are provided with a Test Unit (TU) for performing tests and measurements on SLCAs(subscriber line ckt. Analog), subscribers lines and telephones.

Page 9: EWSD SYSTEM PPT

MAIN COMPONENTS OF DLU SLMAs and / or SLMDs 

Two Digital Interface Units for DLU (DIUD) for connections of the PDCs. 

Two DLU Controls (DLUC)

Two 4 Mbps networks for the transmission of user information between SLMs and the DIUDs.

Two control network for the transmission of control information between SLMs and DLUCs. 

Test Unit (TU), External Alarm module (ALEX) Alarm modules.

Page 10: EWSD SYSTEM PPT

.

DLU

Test line

DIUD0

DLUC1

DIUD1

DLUC0

PDC1

PDC0

PDC2

PDC3

to

two

LTGs

SLMA

SLMD

Test

4096 kbps network 0

4096 kbps network 1

Control network 0

Control network 1

TU

Analog

and ISDN

Subscriber

lines, PBX

lines

Main Components of a DLU

.

Page 11: EWSD SYSTEM PPT

LTG(LINE/TRUNK GROUPS)

The line/trunk groups (LTG) forms the interface between the digital environment of an EWSD exchange and the switching network (SN).

Maximum traffic handling capacity per LTG is 100 Erlang.

Page 12: EWSD SYSTEM PPT

PRIMARY FUNCTIONS OF LTG

Call processing functions – receiving and analyzing line and register signals.

Safeguarding functions – detecting errors in the LTG and on transmission paths within LTG.

Operation and maintenance functions –acquiring traffic data, carrying out quality-to-service measurements.

Page 13: EWSD SYSTEM PPT

FUNCTIONAL UNITS OF THE LINE/TRUNK GROUPS

Line / Trunk Unit (LTU) :-

Digital Interface unit ( DIU30 ) for connection of 2 Mbps digital trunks and either DLU or PA.

Code Receivers (CR) are Multi-frequency code receivers for trunks or DTMF subscribers.

Conference Unit, module B or module C (COUB or COUC) for conference calls. This is installed in special function LTGMs or LTGNs.

Automatic Test Equipment for Trunks (ATE:N) checks trunks and Tone Generators (TOG) during routine tests. This is installed in special function LTGMs or LTGNs.

Page 14: EWSD SYSTEM PPT

.(8Mbps)

Address signals

SIHO

SIHI

SPHO

SPHI

LTU

DIU30

LTU

COUB

LTU

CR

LTU

ATE:T

CR TOG CTC

SU

SN0

SN1

to/from SN (8Mbps)

GS LIU

or

or

or

GP (PU, MU, SMX and GCG) SILC

Internal Structure of LTG

DIU:LDIB

COUC

PHMA

OCANEQ

.

Page 15: EWSD SYSTEM PPT

SIGNALLING UNIT (SU) :-

Tone Generator (TOG) for audible tones.

Code Receivers (CR) for MFC signalling and push-button dialling.

Receiver Module for Continuity Check (RM:CTC), etc.

Group Switch (GS) :- which functions as non-blocking time stage switch

(512 TS) controlled by the GP.

Link Interface Unit (LIU) :- connects LTG to SN via two parallel 8 Mbps SDCs.

Page 16: EWSD SYSTEM PPT

GROUP PROCESSOR (GP) :-

controls the functional units of the LTG. The received signals from LTU, SU, GS and LIU are processed with the help of GP software.

Page 17: EWSD SYSTEM PPT

SWITCHING NETWORKS

Different peripheral units of EWSD, i.e., LTGs, CCNC, MB are connected to the Switching Network (SN) .

Through 8192 kbps highways called SDCs (Secondary Digital Carriers), which have 128 channels each.

It consists of several duplicated Time Stage Groups (TSG) and Space Stage Groups (SSG) housed in separate racks.

Connection paths through the TSGs and SSGs are switched by the SGC.

Each TSG can accommodate 63 SDCs from LTGs and one SDC to MB.

Page 18: EWSD SYSTEM PPT

.

LTG 1

LTG n

CCNC

CP

SPACE STAGE GROUP

TIME STAGE GROUP

SGC

SGC

Switching Network

SDC:LTG

SDC:LTG

SDC:CCNC

SDC:TSG

SDC:SGC

SDC:SGC

SN

MB

SDC:SSG

SDC:SSG

.

Page 19: EWSD SYSTEM PPT

COORDINATION PROCESSOR

Storage and administration of all programs, exchange and sub scriber data.

Processing of received information for routing, path selection, zoning, charges.

Communication with operation and maintenance centres.

Supervision of all subsystems, receipt of error messages, alarm treatment, error messages.

Handling of the man-machine interface.

Page 20: EWSD SYSTEM PPT

BASIC FUNCTIONAL UNITS OF CP 113C

o Base Processor (BAP) – for operation & maintenance and call processing.

Common Memory (CMY) – 64 to 1024 MB in 4 memory banks consisting of 4

Mb DRAM chips.

Input / Output Controller (IOC) – 2 to 4 IOCs coordinate and supervise accessing of

CMY by IOPs.

Page 21: EWSD SYSTEM PPT

.

ATM Bridge Processor (AMP) –

If a SSNC (EWSD powermode) is connected, the AMP is used . It represents the interface between the ATM equipment in the SSNC and the CP.

Input/output processors (IOP) –

Various types of IOPs are used to connect the CP113C to the other subsystems and functional units of the exchange as well as to the external mass storage devices .

Page 22: EWSD SYSTEM PPT

.Maximum configuration of CP113C

CAP0 IOC1IOC0BAPSBAPMCAP5

IOP

IOP IOP

IOP

CMY1

CMY0

IOC3IOC2

IOP IOP

IOP IOPBasic configuration of CP 113C,

11

.

.

0

11

.

.

0

B:IOC B:IOC

AMP0 AMP1

Hardware Structure of CP 113 C

.

Page 23: EWSD SYSTEM PPT

COMMON CHANNEL SIGNALLING NETWORK CONTROL (CCNC) 

It consists of :-

Up to 32 signalling link terminal (SILT) groups, each with 8 signalling links and

One duplicated common channel signaling network processor (CCNP).

Page 24: EWSD SYSTEM PPT

FUNCTIONS OF CCNC :-

In the originating or desti nation exchange in associated signalling, it operates as signalling end point (SEP) .

In transit exchange in quasi-associated signalling, it operates as a signalling transfer point (STP).

 

Page 25: EWSD SYSTEM PPT

.

CCS via digital data links

CCS via analog data links

0 310 31

0 70 7

SILT group 31SILT group 0

CCNP 0 CCNP 1

CP bus system

Common Channel Signalling Network Control

MultiplexerModem

.

Page 26: EWSD SYSTEM PPT

.

Trunks and SS7 Links

LTG

LTG

SNB

CCNC

MB B

IOP:MB IOP:MB

CP

EWSD Classic Configuration

PCM30

8 Mb/s

4 Mb/s OMT/OMT/CT

.

LTG

LTG

SNB

SSNC

MB D

AMPC IOP:MB

CP

EWSD Powermode Configuration

Trunks and SS7 Links

PCM30/24

270 Mb/s

207 Mb/s

High Speed

SS7 Links

NetM

Page 27: EWSD SYSTEM PPT

SIGNALING SYSTEM NETWORK CONTROL (SSNC)

a) ATM Switching Network ASN (2 module frames for ASN 0 and 1)

Switches the communication- streams of the individual SSNC functional units with MB-D and CP.

Switches the communication-streams between the individual SSNC functional units.

Page 28: EWSD SYSTEM PPT

.

b) SSNC basic frames SCB

Line Interface Card (LIC):

The duplicated Line Interface Card LIC forms the physical interface between the SSNC units and the SS7 network.

Main Processor MP:

MP: OAM :MP for Operation , Administration and Maintenance.

MP:SLT :MP for Signalling Link Termination. MP:SM :MP for Signalling Manager. MP:STATS :MP for statistics.

Page 29: EWSD SYSTEM PPT

.

ATM Multiplexer Type-E (AMXE):

Provides 32 x 207 Mbps ATM interfaces to connect the internal SSNC units LIC and MP and the optical cables to the AMP of the CP and MBDA of the MB.

c) Extension frame SCE (maximum 7 for 1500 signalling channels)

The SCE contains a duplicated AMXE and serves to include other MPs and LICs .

Page 30: EWSD SYSTEM PPT

.

Output LTG

ISUP LTG

Inward LTG

AMP MB- D (MBDA)

CP

SNSignaling link

Affecting speech channel

SSNC

OAM

Level 2 & 3(MTP)

Net M

31 SS7- Links

with 64 Kbit/s

or

1 HS- Link

with 2 Mb/S

Direct connected E1 exclusively used for

SS7 links

SSNC Interfaces

.

Page 31: EWSD SYSTEM PPT

.

.

Page 32: EWSD SYSTEM PPT

.


Recommended