+ All Categories
Home > Documents > EXGA 900

EXGA 900

Date post: 02-Jun-2018
Category:
Upload: tuan-tocdai
View: 249 times
Download: 6 times
Share this document with a friend

of 17

Transcript
  • 8/11/2019 EXGA 900

    1/17

    Nokia Siemens Networks

    GSM/EDGE BSS, rel.

    RG10(BSS), operatingdocumentation, issue 06

    Flexi EDGE BTS Dual TRX Module (EXxx)

    Description

    DN70178382

    Issue 4-0

    Approval Date 2009/10/16

  • 8/11/2019 EXGA 900

    2/17

    2 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063dfd0

    The information in this document is subject to change without notice and describes only the

    product defined in the introduction of this documentation. This documentation is intended for the

    use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted

    in any form or means without the prior written permission of Nokia Siemens Networks. The

    documentation has been prepared to be used by professional and properly trained personnel,

    and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes

    customer comments as part of the process of continuous development and improvement of the

    documentation.

    The information or statements given in this documentation concerning the suitability, capacity,

    or performance of the mentioned hardware or software products are given "as is" and all liability

    arising in connection with such hardware or software products shall be defined conclusively and

    finally in a separate agreement between Nokia Siemens Networks and the customer. However,

    Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions

    contained in the document are adequate and free of material errors and omissions. Nokia

    Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which

    may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

    EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-

    TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-

    RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED

    TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY

    OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION

    IN IT.

    This documentation and the product it describes are considered protected by copyrights and

    other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark

    of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2010. All rights reserved

    f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment.

    Some of the parts may also have elevated operating temperatures.

    Non-observance of these conditions and the safety instructions can result in personal

    injury or in property damage.

    Therefore, only trained and qualified personnel may install and maintain the system.

    The system complies with the standard EN 60950 / IEC 60950. All equipment connected

    has to comply with the applicable safety standards.

    The same text in German:

    Wichtiger Hinweis zur Produktsicherheit

    In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Span-

    nung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen.

    Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverlet-

    zungen und Sachschden fhren.

    Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die

    Anlagen installiert und wartet.

    Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene

    Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

  • 8/11/2019 EXGA 900

    3/17

    DN70178382

    Issue 4-0

    3

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063dfd0

    Table of ContentsThis document has 17 pages.

    1 Summary of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    2 Dual TRX Module (EXxx). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    3 Dual TRX Module (EXxx) main blocks. . . . . . . . . . . . . . . . . . . . . . . . . . 10

    4 Dual TRX Module (EXxx) power requirements . . . . . . . . . . . . . . . . . . . 12

    5 Dual TRX Module (EXxx) interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    6 Dual TRX Module (EXxx) dimensions and weight . . . . . . . . . . . . . . . . . 15

    7 Dual TRX Module (EXxx) LED indications. . . . . . . . . . . . . . . . . . . . . . . 16

    8 Contents of the Dual TRX Module (EXxx) delivery . . . . . . . . . . . . . . . . 17

  • 8/11/2019 EXGA 900

    4/17

    4 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063dfd0

    List of FiguresFigure 1 Dual TRX Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    Figure 2 Dual TRX Module main blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    Figure 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors and labels .

    13

  • 8/11/2019 EXGA 900

    5/17

    DN70178382

    Issue 4-0

    5

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063dfd0

    List of TablesTable 1 Dual TRX Module (EXxx) input voltage range . . . . . . . . . . . . . . . . . . . 12

    Table 2 Dual TRX Module (EXxx) power consumption . . . . . . . . . . . . . . . . . . . 12

    Table 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors, cable types

    and interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    Table 4 EXxx dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Table 5 Dual TRX Module LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    Table 6 Flexi EDGE Dual TRX Module (EXxx) delivery contents . . . . . . . . . . . 17

  • 8/11/2019 EXGA 900

    6/17

    6 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063dfd0

  • 8/11/2019 EXGA 900

    7/17

    DN70178382

    Issue 4-0

    7

    Flexi EDGE BTS Dual TRX Module (EXxx) Description Summary of changes

    Id:0900d8058063dfba

    1 Summary of changes

    Changes between issues 4-0 and 3-0

    Updated chapters:

    Dual TRX Module (EXxx)was updated with hardware support information. A note

    about installation was added.

    Dual TRX Module (EXxx) power requirementswere updated

    Dual TRX Module (EXxx) LED indicationswere updated

    Contents of the Dual TRX Module (EXxx) deliverywas updated.

    Changes between issues 3-0 and 2-0

    Updated chapters:

    Dual TRX Module (EXxA)updated with information on Intelligent Downlink Diversity

    (IDD) TRX. The figure Isometric view of the Dual TRX Module updated. Module dimensions and weightsupdated with information on Dual TRX weight.

    Contents of the EXxA deliveryupdated with information on preinstalled screws.

    Changes between issues 2-0 and 1-0

    New chapters:

    Summary of Changesadded.

    Updated chapters:

    Dual TRX Module (EXxA) main blocksadded the Fan Module to the bulleted list.

    Dual TRX Module (EXxA) power requirements Table 2 updated with explanations

    of terms maximum, nominal, idle and one PA in use.

    Dual TRX Module (EXxA) interfacesadded two notes to table 3.

    Dual TRX Module (EXxA) LED indicationsTable 5 updated with information on

    cycling colours.

  • 8/11/2019 EXGA 900

    8/17

    8 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063db4e

    Dual TRX Module (EXxx)

    2 Dual TRX Module (EXxx)The Dual TRX Module (EXxx) is a two-carrier TRX unit. The module contains the

    common (2 carrier) baseband part and two separate RF parts for two transceivers

    (transmitter and receiver chains) and space for two optional Wideband Combiner

    Modules (Ewxx).

    The Dual TRX Module (EXxB) hardware can simultaneously support the following future

    BSS features:

    Full Voice services over Adaptive Multi-user Orthogonal Sub channels (VAMOS)

    Enhanced General Packet Radio Service Evolution (EGPRS2)

    The Dual TRX Module (EXxx) is used as:

    a combined module with the Dual Duplexer Module (ERxx), making a logical Sector

    Module

    or a stand-alone TRX module with the Remote Tune Combiner (ECxA) Module or a stand-alone extension TRX module.

    The Dual TRX Module and System Module (ESMA) communication is managed through

    a single Ethernet interface. Each transceiver within the Dual TRX Module can be sepa-

    rately activated with a licence key at the BSC.

    The Dual TRX Module contains two transceivers that can be used:

    as a separate TRX in the same sector

    as a separate TRX in different sectors

    or as a Double Power TRX.

    or as an Intelligent Downlink Diversity (IDD) TRX.

    There are separate Dual TRX Modules for each frequency band that Flexi EDGE BTSsupports:

    EXTx GSM800

    EXGx GSM900

    EXDx GSM1800

    EXPx GSM1900

    See the following figure for an isometric view of the Dual TRX Module.

  • 8/11/2019 EXGA 900

    9/17

    DN70178382

    Issue 4-0

    9

    Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx)

    Id:0900d8058063db4e

    Figure 1 Dual TRX Module

    gThe installation instructions for EXxA are the same as for EXxB.

    DN70185036

  • 8/11/2019 EXGA 900

    10/17

    10 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063db59

    Dual TRX Module (EXxx) main blocks

    3 Dual TRX Module (EXxx) main blocksThe Dual TRX Module (EXxx) includes the following functional blocks:

    Baseband TRX, O&M, telecom and digital signal processing (DSP)

    Ethernet interface for control, user and baseband hopping data

    Synchronisation

    Digital up/down conversion and filtering

    TX and RX data conversion

    TX Double Power support

    Intelligent Downlink Diversity (IDD)

    4-way Uplink Diversity support

    RX 4-Way Interference Reject Combining (IRC) support

    Temperature management

    Power supply

    Power distribution of TRX internal supply voltages

    Transmitter

    Direct conversion from TX interface to TX RF

    Digital power control

    TX Double Power and IDD support

    Receiver

    Dual down-conversion from RX RF to RX interface

    Diversity reception

    Digital Automatic Gain Control (AGC)

    Synthesisers

    Local oscillator signals for TX and RX up/down conversions

    Frequency hopping capability on timeslot basis

    Fan Module

  • 8/11/2019 EXGA 900

    11/17

    DN70178382

    Issue 4-0

    11

    Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx) main blocks

    Id:0900d8058063db59

    In 2-way diversity case the signal comes from DTRX's other Rx main connector

    and with 4-way diversity the signal comes from the diversity Rx connector.

    PSU - power supply unit, BB - baseband, IF - interface, DP - double power, FHS

    - frequency hopping system, PA - power amplifier

    Figure 2 Dual TRX Module main blocks

    Dual TRX Module

    Fan Module

    BB Module

    BB

    PSU (All voltages)

    DataConverter

    Power,Data, IFsignals,Controlsignals

    andClock

    Fan Connector

    TX2Chain

    DivRX2

    MainRX

    2

    RXFFS

    DivRX1

    MainRX

    1

    RX FHS 1 & 2

    28VPSU

    28VPSU

    TX FHS 1 & 2

    Supports DP functionality

    BUS

    ERxA

    PWR(48 V)

    DP

    TX1Chain

    PA

    Module

    PA

    Module

    TxA RxA

    RxA_Div

    RxB

    RxB_Div

    TxB

    TRX Module

    DN70185184

  • 8/11/2019 EXGA 900

    12/17

    12 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063dbac

    Dual TRX Module (EXxx) power requirements

    4 Dual TRX Module (EXxx) power requirements

    Maximum: maximum power consumption, 2 carriers ON all the time at Power Level 0

    Nominal: expected (average) power consumption, 2 carriers ON all the time at Power

    Level 0

    Idle: no Power Amplifiers ON (for example, no active timeslots)

    One PA in Use: expected (average) power consumption, 1 carrier ON all the time at

    Power Level 0

    Note that the power consumption of the Dual Duplexer Module or MHAs are not included

    in the table even though they are fed through the Dual TRX Module.

    Property Value

    Nominal system voltage 48 V DC

    Input voltage range 40.5 - 57 V DC

    Table 1 Dual TRX Module (EXxx) input voltage range

    EXTx/EXGx (800/900) EXDx (1800) EXPx (1900)

    Maximum 325 W 365 W 385 W

    Nominal 295 W 335 W 355 W

    Idle 39 W (EXTA/EXGA)

    45 W (EXTB/EXGB)

    37 W (EXDA)

    50 W (EXDB)

    37 W (EXPA)

    50 W (EXPB)

    One PA in use 180 W 200 W 210 W

    Table 2 Dual TRX Module (EXxx) power consumption

  • 8/11/2019 EXGA 900

    13/17

    DN70178382

    Issue 4-0

    13

    Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx) interfaces

    Id:0900d8058063dbb2

    5 Dual TRX Module (EXxx) interfaces

    Figure 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors and labels

    DN70131596

    Bus

    ER_A PWR DP

    TxA RxA

    RxADiv

    RxBDiv

    RxB

    Caution,Hot Surface

    Electrostaticalsensitive device

    Groundingpoint

    TxB

    LED

    Label name

    on module

    Description Connector

    type

    Cable type Interface(s) Signal

    direction

    (to/from

    the

    module)

    BUS Ethernet (1000 Base-

    T/100 Base-TX)baseband processing

    of end user, hopping,

    synchronisation, and

    O&M data

    MDR 26

    (female)

    Bus cable, AWG30

    Twinax, MDR 26

    (male)

    length: 1054/1554

    mm (41.5/61.2 in.)

    ESMA, ESEA To and

    from themodule

    ER_A Power and control

    interface for the ERxA

    MDR 36

    (female) ERxA cable, MDR

    36 (male)

    hard-wired with

    other end fixed to

    ER_A

    length: 200 mm (7.9

    in.)

    ERxA To and

    from the

    module

    PWR -48 VDC input powerwith fuse protection

    Multi-BeamXL (female)

    Power cable, 2 xAWG12, Multi-Beam

    XL (male)

    length: 1188/2000

    mm (46.8/78.7 in.)

    ESMA, ESEA To andfrom the

    module

    Table 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors, cable types and interfaces

  • 8/11/2019 EXGA 900

    14/17

    14 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063dbb2

    Dual TRX Module (EXxx) interfaces

    DP Synchronous combin-

    ing of both transmit-

    ters in the module to

    generate one

    GSM/EDGE carrier

    capacity with

    increased output

    power

    NOTE: Interface to

    the EWxA (required

    module with the DP

    feature)

    Molex Microfit

    (male) DP cable, 4 x

    AWG24, Molex

    Microfit (female)

    length: 203 mm (8.0

    in.)

    EWxA To and

    from the

    module

    RxA, RxB

    (blue)

    Receives a digitally

    modulated

    GSM/EDGE RF

    carrier in accordance

    with the appropriate

    telecommunications

    standard (Rx input)

    QMA

    (female) RF cable, SemiFlex

    50, QMA (male)

    length:

    172/275/1300 mm

    (6.8/10.8/51.2 in.)

    ERxA, ECxA To the

    module

    RxA Div , RxB

    Div (blue)

    Four-way uplink

    receive diversity

    (4UD)

    NOTE: This connector

    is also used in 2UD

    configurations which

    require splitting an

    EXxx between cell

    areas (for example,

    cost optimized config-

    urations, 1+3).

    QMA

    (female) RF cable, SemiFlex

    50, QMA (male)

    length:

    172/275/1300 mm

    (6.8/10.8/51.2 in.)

    ERxA, ECxA To the

    module

    TxA, TxB (red) Transmits a digitally

    modulated

    GSM/EDGE RF

    carrier in accordance

    with the appropriate

    telecommunications

    standard (Tx output).

    QMA

    (female) RF cable, SemiFlex

    50, QMA (male)

    length:

    172/275/1300 mm

    (6.8/10.8/51.2 in.)

    ERxA, EWxA,

    ECxA

    From the

    module

    Label name

    on module

    Description Connector

    type

    Cable type Interface(s) Signal

    direction

    (to/from

    the

    module)

    Table 3 Flexi EDGE Dual TRX Module (EXxx) front panel connectors, cable types and interfaces (Cont.)

  • 8/11/2019 EXGA 900

    15/17

    DN70178382

    Issue 4-0

    15

    Flexi EDGE BTS Dual TRX Module (EXxx) Description Dual TRX Module (EXxx) dimensions and weight

    Id:0900d8058063dbf3

    6 Dual TRX Module (EXxx) dimensions and

    weight

    The dimensions of the Flexi EDGE Dual TRX Module are presented in the table below.

    1)Width of the casing without front covers/with front covers

    2)Depth of the casing without front covers/with front covers

    Property Value

    Width 1) 447/492 mm

    (17.6/19.4 in.)

    Height 90 mm

    (3.5 in.)

    Depth 2) 422/560 mm

    (16.6/22.1 in.)

    Weight 7.58 kg

    (16.7 lbs)

    Table 4 EXxx dimensions and weight

  • 8/11/2019 EXGA 900

    16/17

    16 DN70178382

    Issue 4-0

    Flexi EDGE BTS Dual TRX Module (EXxx) Description

    Id:0900d8058063de43

    Dual TRX Module (EXxx) LED indications

    7 Dual TRX Module (EXxx) LED indicationsThe Dual TRX Module (EXxx) has two tri-colour LEDs on the front panel to indicate the

    operational status of the module and all fault conditions during operation.

    Colour Explanation

    Cycling colours BTS has requested highlighting for TRX module and

    timer is still running.

    Red, blinking 7606 alarm is active on one of the carriers or

    7607 alarm is active on one or on both carriers.

    7607 alarm on IDD TRX or DPTRX TRX object.

    Red, stable TRX_OM SW is not running or

    7606 alarm is active on both carriers.

    7606 alarm on IDD TRX or DPTRX TRX object.

    Yellow, blinking TRX_OM SW state is Clock sync or

    one or both carriers are in TRX_OM SW state TRX con-

    figuring, Wait for OMUSIG establishment or Wait for

    system information.

    Yellow, stable Both carriers are blocked from BTS or

    both carriers have TRXSIG channel disconnected when

    in TRX_OM SW state is supervisory.

    IDD TRX or DPTRX object blocked/locked or IDD TRX or

    DPTRX TRX object is Shutdown (but is still providing

    power/control for DDU supporting other TRX's or are

    powered due to malfunctioning e.g. power cycle in

    ESEA) from BSC or

    IDD TRX or DPTRX TRX object has TRXSIG channel

    disconnected when the carrier state is supervisory.

    Green, blinking Only one carrier is in the supervisory state and no 7606

    or 7607 alarm is active and LAPD on TRXSIG is con-

    nected for this carrier, or.

    both carriers are in supervisory state but one carrier has

    LAPD on TRXSIG channel disconnected.

    Not applicable when the TRX module is configured for

    IDD TRX or DPTRX TRX object.

    Green, stable Both carriers are in TRX_OM SW state supervisory and

    no 7607 or 7606 alarms are active.IDD TRX or DPTRX TRX object is in supervisory state

    and no 7606 / 7607 alarms are active and TRXSIG is

    connected.

    Table 5 Dual TRX Module LED indications

  • 8/11/2019 EXGA 900

    17/17

    DN70178382 17

    Flexi EDGE BTS Dual TRX Module (EXxx) Description Contents of the Dual TRX Module (EXxx) delivery

    Id:0900d8058063de9c

    8 Contents of the Dual TRX Module (EXxx)

    delivery

    Description Product code Quantity

    EDGE Dual TRX Module (EXxx): 1

    EDGE Dual TRX Module 800 MHz (EXTA)

    EDGE Dual TRX Module 800 MHz (EXTB)

    EDGE Dual TRX Module 900 MHz (EXGA)

    EDGE Dual TRX Module 900 MHz (EXGB)

    EDGE Dual TRX Module 1800 MHz (EXDA)

    EDGE Dual TRX Module 1800 MHz (EXDB)

    EDGE Dual TRX Module 1900 MHz (EXPA)

    EDGE Dual TRX Module 1900 MHz (EXPB)

    470214A

    472043A

    470215A

    472044A

    470216A

    472045A

    470217A

    472046A

    Dual TRX Module Cable Set: 083309A 1

    Power cable 1188 mm (46.8 in.) 994940 1

    Bus cable 1054 mm (41.5 in.) 994938 1

    RF cable 172 mm (6.8 in.) 994931 4

    M5 thumbscrews (preinstalled) 4

    Table 6 Flexi EDGE Dual TRX Module (EXxx) delivery contents


Recommended