About L&T
Larsen & Toubro is a technology-driven company that
infuses engineering with imagination. The Company
offers a wide range of advanced solutions in the field of
Engineering, Construction, Electrical & Automation,
Machinery and Information Technology.
L&T Switchgear, a part of the Electrical & Automation
business, is India's largest manufacturer of low voltage
switchgear, with the scale, sophistication and range to
meet global benchmarks. With over five decades of
experience in this field, the Company today enjoys a
leadership position in the Indian market with a growing
international presence.
It offers a complete range of products including
powergear, controlgear, industrial automation,
building electricals & automation, reactive power
management, energy meters, and protective relays.
These products conform to Indian and International
Standards.
2
L&T Final Distribution ProductsL&T’s range of modular devices offer MCB, RCCB, Isolator & DB for final distribution of electrical power.
L&T’s products are better known for reliability, functionality & ease of use.
L&T spell world class
Final Distribution Products L&T products conform to relevant
global standards viz. IEC, EN.
They also have BIS, marking,
CB and certification.
Distribution Boards
MCB - Miniature Circuit Breaker
RCCB - Residual Current Circuit Breaker
Isolators
Contents
Other Protection & Control Devices
12
4
6
7
7
EN
Note: Colour of HSN code signifies below
*Subject to change as per Govt. notification
[Green colour : 18%* GST][Red colour : 28%* GST]
3
Safety re-defined
Finger proof terminals eliminate chances of accidental contact with live part.
You can install, operate and maintain modular device with total confidence.
Two position DIN rail clip
Installation on a DIN rail is further simplified with a two-position DIN rail clip
as a standard feature. L&T MCB range makes mounting on a standard DIN
rail more convenient than most.
Large terminal size and dual termination
L&T MCBs can easily accommodate cables of up to 35 sq. mm. The terminals
are designed to facilitate termination of cable or bus bar or both at incomer
side.
Non-welding contacts
Silver Graphite contact tips ensure higher life and maximum safety against
contact welding due to its superior anti-welding properties, enhancing
safety and life of the system.
Combihead screw
L&T modular devices with combihead screws, allow you to use standard as
well as Philips head screw drivers. L&T modular device range addresses
your undefined needs.
Safety meets superior aesthetics
Ergonomically designed, profiled for superior cooling and manufactured
with fire retardant material. Modular device is brought to you keeping in mind
utmost user safety.
Innovatively profiled breathing channels
When two or more poles are placed adjacent to each other, the breathing
channels are so profiled that the air circulates around individual pole,
resulting in cooler operation.
True contact indication
L&T modular device range enhances safety through true contact indication
even from a distance regardless of its mounting and knob position. Red and
Green indication tags provided below the knob positively identify the
electrical ON/OFF status, reflecting actual contact status.
Integrated label holder
L&T MCBs are equipped with label holder for easy identification of circuit
during operation as well as in maintenance.
L&T Final Distribution Products - the assurance of absolute safety
Key Benefits
Energy limiting class - 3
If fault occurs, the Rapid Arc Quenching mechanism in modular device
operates and extinguishes the arc quickly (within 3-5 msec), ensuring lowest
possible energy flow through the circuit. This minimize risk of fire and
maximizes life of your equipment.
certif iedMiniature Circuit Breaker [8536]
MCB (10kA)
ONO
FFLab
el
Holde
r
4
Single Pole (SP)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
BB10E50C
BB10010C
BB10020C
BB10030C
BB10040C
BB10060C
BB10100C
BB10160C
BB10200C
BB10250C
BB10320C
BB10400C
BB10500C
BB10630C
0.5A
1A
2A
3A
4A
6A
10A
16A
20A
25A
32A
40A
50A
63A
BB10060B
BB10100B
BB10160B
BB10200B
BB10250B
BB10320B
BB10400B
BB10500B
BB10630B
208
208
208
208
208
208
475
475
475
-
-
-
-
-
-
-
-
-
-
320
320
320
320
320
208
208
208
208
208
208
475
475
475
BB10E50D
BB10010D
BB10020D
BB10030D
BB10040D
BB10060D
BB10100D
BB10160D
BB10200D
BB10250D
BB10320D
BB10400D
BB10500D
BB10630D
BB10E5DC
BB1001DC
BB1002DC
BB1003DC
BB1004DC
BB1006DC
BB1010DC
BB1016DC
BB1020DC
BB1025DC
BB1032DC
BB1040DC
BB1050DC
BB1063DC
Double Pole (DP)
2
2
2
2
2
2
2
2
2
2
2
2
2
2
0.5A
1A
2A
3A
4A
6A
10A
16A
20A
25A
32A
40A
50A
63A
BB20E50C
BB20010C
BB20020C
BB20030C
BB20040C
BB20060C
BB20100C
BB20160C
BB20200C
BB20250C
BB20320C
BB20400C
BB20500C
BB20630C
B 20060B
BB20100B
BB20160B
BB20200B
BB20250B
BB20320B
BB20400B
BB20500B
BB20630B
B 660
660
660
660
660
660
1080
1080
1080
-
-
-
-
-
-
-
-
-
-
875
875
875
875
875
660
660
660
660
660
660
1080
1080
1080
BB20E50D
BB20010D
BB20020D
BB20030D
BB20040D
BB20060D
BB20100D
BB20160D
BB20200D
BB20250D
BB20320D
BB20400D
BB20500D
BB20630D
BB20E5DC
BB2001DC
BB2002DC
BB2003DC
BB2004DC
BB2006DC
BB2010DC
BB2016DC
BB2020DC
BB2025DC
BB2032DC
BB2040DC
BB2050DC
BB2063DC
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
B-CurveCat. Nos.
C-CurveCat. Nos.
D-CurveCat. Nos.
M.R.P. (`)
Per Unit
M.R.P. (`)
Per Unit
M.R.P. (`)
Per Unit
DC MCBsCat. Nos.
M.R.P. (`)
Per Unit
Current Rating (In)
Modules1 Mod = 17.5 mm
*
*
* Available on request.
325
325
325
325
325
280
280
280
280
280
280
505
470
470
470
470
470
400
400
400
400
400
400
525
525
525
*
*
890
890
890
890
890
680
680
680
680
680
680
1100
960
960
960
960
960
845
845
845
845
845
845
1150
1150
1150
New
l True contact indication for individual pole
l Label holder facility for all configurations
l Conforms to IS/IEC 60898 and IEC 60947 -2
l Breaking capacity of 10kA throughout the range
l Available in B, C & D curves
l Low watt loss - almost 50% of the values prescribed by IS/IEC 60898
l Trip free mechanism
l Design based on advanced current limiting hammer trip mechanism
l No Line-Load bias
l Suitable for accessory fitment
l DC MCBs as per IEC 60947-2 - Rated Voltage:130V DC (for SP), 250V DC (for DP) with breaking capacity of 6 kA
Three Pole (TP)
3
3
3
3
3
3
3
3
3
3
3
3
3
3
0.5A
1A
2A
3A
4A
6A
10A
16A
20A
25A
32A
40A
50A
63A
BB30E 0C
BB30010C
BB30020C
BB30030C
BB30040C
BB30060C
BB30100C
BB30160C
BB30200C
BB30250C
BB30320C
BB30400C
BB30500C
BB30630C
5
BB30060B
BB30100B
BB30160B
BB30200B
BB30250B
BB30320B
BB30400B
BB30500B
BB30630B
1075
1075
1075
1075
1075
1075
1650
1650
1650
-
-
-
-
-
-
-
-
-
-
BB30E 0D
BB30010D
BB30020D
BB30030D
BB30040D
BB30060D
BB30100D
BB30160D
BB30200D
BB30250D
BB30320D
BB30400D
BB30500D
BB30630D
51215
1215
1215
1215
1215
1075
1075
1075
1075
1075
1075
1650
1650
1650
Four Pole (FP)
0.5A
1A
2A
3A
4A
6A
10A
16A
20A
25A
32A
40A
50A
63A
BB40E50C
BB40010C
BB40020C
BB40030C
BB40040C
BB40060C
BB40100C
BB40160C
BB40200C
BB40250C
BB40320C
BB40400C
BB40500C
BB40630C
BB40E50D
BB40010D
BB40020D
BB40030D
BB40040D
BB40060D
BB40100D
BB40160D
BB40200D
BB40250D
BB40320D
BB40400D
BB40500D
BB40630D
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1450
1450
1450
1450
1450
1450
2075
2075
2075
BB40060B
BB40100B
BB40160B
BB40200B
BB40250B
BB40320B
BB40400B
BB40500B
BB40630B
-
-
-
-
-
-
-
-
-
-
1690
1690
1690
1690
1690
1450
1450
1450
1450
1450
1450
2075
2075
2075
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP- 4 Nos., FP - 3 Nos.
Auxiliary & Accessories for MCBs [8538]
Auxiliary Contact - 6A , 240V AC, (1NO+1NC), 0.5 Mod
Shunt Release - 240V AC, 1
Trip Alarm Contact - 6A, 240V AC, (1NO+1NC), 0.5 Mod
Mod
BZA11006
BZS00240
BZT11006
M.R.P. (`)
Per Unit
690
1845
805
Cat. Nos.Description
B-CurveCat. Nos.
C-CurveCat. Nos.
D-CurveCat. Nos.
M.R.P. (`)
Per Unit
M.R.P. (`)
Per Unit
M.R.P. (`)
Per Unit
Current Rating (In)
Modules1 Mod = 17.5 mm
*
*
*
*
* Available on request.
1245
1245
1245
1245
1245
1100
1100
1100
1100
1100
1100
1710
1715
1715
1715
1715
1715
1475
1475
1475
1475
1475
1475
2125
5
certif iedResidual Current Circuit Breaker [8536]
RCCB
l Conforms to IS 12640 (Part 1) / IEC 61008-1
l RCCBs are available in DP and FP versions from 25 to 100A ratings with 30 mA, 100 mA and 300 mA sensitivity
l Truly current operated - operation even at nominal voltage
l Operates on Core Balance Current Transformer (CBCT) principle
l Operation even in case of neutral failure
l Advanced neutral mechanism
IP20FingerproofTerminals
L&T wire
OR / AND
6
Double Pole (DP)
25A
40A
63A
100A
2
2
2
2
2
2
2
2
2
2
2
2
Four Pole (FP)
25A
40A
63A
100A
4
4
4
4
4
4
4
4
4
4
4
4
BG202503
BG202510
BG202530
BG204003
BG204010
BG204030
BG206303
BG206310
BG206330
BG210003
BG210010
BG210030
2340
2435
2435
2640
2785
2785
3305
3390
3390
5835
5910
5910
BG402503
BG402510
BG402530
BG404003
BG404010
BG404030
BG406303
BG406310
BG406330
BG410003
BG410010
BG410030
Modules1 Mod = 17.5 mm Cat. Nos.Sensitivity
M.R.P. (`)
Per Unit
Current Rating (In)
30
100
300
30
100
300
30
100
300
30
100
300
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
30
100
300
30
100
300
30
100
300
30
100
300
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
3075
3190
3190
3100
3235
3235
3545
3720
3720
6370
6485
6485
certif ied
Isolators [8536]
ONO
FFL&T wire
OR / ANDIP20FingerproofTerminals
l Conforms to IEC 60947-3
l Utilization category
l Available in DP, TP and FP versions in 40A, 63A, 80A & 100A ratings
AC-22A
7
Double Pole (DP)
40A
63A
80A
100A
2
2
2
2
Three Pole (TP)
40A
63A
80A
100A
3
3
3
3
Four Pole (FP)
40A
63A
80A
100A
4
4
4
4
Current Rating (In)
Modules1 Mod = 17.5 mm
Cat. Nos.M.R.P.
(`)Per Unit
BF204000
BF206300
BF208000
BF210000
BF304000
BF306300
BF308000
BF310000
BF404000
BF406300
BF408000
BF410000
Note: Standard Pack Quantity for Isolator : DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
390
500
635
670
685
790
875
885
895
910
1030
1090
Changeover Switches [8536]
l
l
l
Conforms to IEC 60947-3 and IS/IEC 60947-3
Available in 3 positions (I-O-II) with centre off position
Utilization category AC-22A
Cat. Nos.DescriptionM.R.P.
(`) Per Unit
Four Pole
Module
25A
40A
63A
40A
63A
2
2
3
4
6
AUC00202500
AUC00204000
AUC00206300
AUC00404000
AUC00406300
1400
2150
2500
3700
4200
Double Pole
New
8
l
l
Wide Range of Current Ratings
- 25A, 40A and 63A
Conforms to:
- IEC 61095, EN 61095
- IEC 60497-4-1, EN 60497-4-1
- IEC 60497-5-1
Cat. Nos.Description (AC-1)M.R.P.
(`) Per Unit
Module
l
l
Available in:
- 1NO, 2NO, 3NO, 4NO and 2NO+2NC version
Protection Degree IP 20
25A-1NO
25A-2NO
40A-2NO
40A-3NO
40A-4NO
63A-2NO+2NC
63A-3NO
63A-4NO
Auxiliary Contact, 2NO
1
1
3
3
3
3
3
3
0.5
AUMC1002501
AUMC2002501
AUMC2004003
AUMC3004003
AUMC4004003
AUMC2206303
AUMC3006303
AUMC4006303
AUMCAUX240
1340
1670
2870
4010
4800
5100
5200
5720
1600
Time Switches [9107]
Cat. Nos.Description M.R.P.
(`) Per Unit
Module
Analog time switch
Analog time switch
Digital time switch
Astro time switch
1
3
2
2
AUTS01ANA00
AUTS03ANA00
AUTS02DIG00
AUTS02AST00
2450
2400
1875
3150
Cat. Nos.Description M.R.P.
(`) Per Unit
Module
Indicating Lights [8531]
RED
YELLOW
BLUE
GREEN
RED-YELLOW-BLUE
1
1
1
1
1
AUIL01RED00
AUIL01YEL00
AUIL01BLU00
AUIL01GRE00
AUIL01RYB00
825
825
825
825
1000
Modular Contactors [8536]
Energy Meters [9030]• Communication with additional RS485 & WiFi module
• Class 1 accuracy
• Direct current operated meter
• Reverse current indication for three-phase meter
WD4000101OOO
WD4000103OOO
Single Phase (5-40A)
Three Phase (10-60A)
2035
4620
2
7
Cat. Nos.Description M.R.P.
(`) Per Unit
Module
• Short circuit Breaking Capacity - 15kA (IEC 60947-2, EN 60947-2)
• C & D Characteristics
• Available in SP, DP, TP and FP
• Suitable for Isolation
• Protection Degree - IP 20
• Availability of wide Range of Site Mountable Accessories
4.5
4.5
4.5
AU15S31003C
AU15S31253C
AU15S30803C
7335
8140
6885
AU15S31003D
AU15S31253D
AU15S30803D 7305
7785
8635
6
6
6
AU15S41003C
AU15S41253C
AU15S40803C
9350
10580
8990
AU15S41003D
AU15S41253D
AU15S40803D 9522
9925
11225
Rating ModuleC CurveCat. No.
D CurveCat. No.
M.R.P. (`)
Per Unit
M.R.P. (`)
Per Unit
80A
100A
125A
1.5
1.5
1.5
AU15S10803C
AU15S11003C
AU15S11253C
1970
2205
2375
AU15S10803D
AU15S11003D
AU15S11253D
2085
2340
2530
3
3
3
AU15S21003C
AU15S21253C
AU15S20803C 4360
4655
5120
AU15S21003D
AU15S21253D
AU15S20803D 4635
4945
5430
80A
100A
125A
80A
100A
125A
80A
100A
125A
Single Pole
Two Pole
Three Pole
Four Pole
• Conforms to IEC 61643-11
• Available in Type 2 and Type 1+2
• Type 2 : Protection against indirect lightning and switching surges
- Maximum Discharge Current - Imax up to 70kA
• Type 1+2 : Protection against direct and indirect lightning surges
- Maximum Discharge Current - Imax up to 100kA
Cat. Nos.Description M.R.P.
(`) Per Unit
ModuleConfiguration
10800
21200
7500
15000
6000
11800
12000
22000
12000
20000
AUSP121PN50
AUSP123PN50
AUSP021PN40
AUSP023PN40
AUSP021PN15
AUSP023PN15
AUSP121PN100
AUSP123PN100
AUSP021PN70
AUSP023PN70
2
4
1
2
1
2
2
4
2
4
1P+N
3P+N
1P+N
3P+N
1P+N
3P+N
1P+N
3P+N
1P+N
3P+N
Type 1+2,
I 100kAmax
Type
I 50kAmax
1+2,
Type 2,
I 40kAmax
SPDs Surge Protection Devices [8536]
MCB (Miniature Circuit Breakers) : 80A-125A [8536]
9
Type 2,
I 15kAmax
Type 2,
I 70kAmax
New
New
16A
20A
25A
32A
40A
6A
10A
16A
20A
25A
32A
40A
63A
RCBOs (Residual Current Breaker with Overcurrent Protection) [8536]
• Conforms to IEC 61009-1, IS12640-2, EN 61009-1
• Available in
- Type AC- For standard installations
- Type Adi - For installations with presence of pulsating DC
along with transients and harmonics
• Wide Range of Current Ratings - 6A to 63A
• Short Circuit Breaking Capacity - 10kA
• Precise Sensitivities for a variety of applications - from 10mA to 300mA
• 2P & 4P versions
• Suitable for Isolation
• Protection Degree - IP 20
• Availability of wide Range of Site Mountable Accessories
Type-AC
Type-Adi
Rating Module CAT Nos.M.R.P.
(`)Per Unit
Sensitivity
2P AC
10mA
30mA
100mA
300mA
10mA
30mA
100mA
300mA
10mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
AUF3C200601
AUF3C200603
AUF3C200610
AUF3C200630
AUF3C201001
AUF3C201003
AUF3C201010
AUF3C201030
AUF3C201601
AUF3C201603
AUF3C201610
AUF3C201630
AUF3C202003
AUF3C202010
AUF3C202030
AUF3C202503
AUF3C202510
AUF3C202530
AUF3C203203
AUF3C203210
AUF3C203230
AUF3C204003
AUF3C204010
AUF3C204030
AUF3C206303
AUF3C206310
AUF3C206330
3605
3605
3685
3705
3605
3605
3685
3705
3605
3605
3685
3705
3605
3685
3705
3605
3685
3705
3605
3685
3705
3605
3685
3705
4625
4900
4940
16A
20A
25A
32A
40A
63A
Rating Module CAT Nos.M.R.P.
(`)Per Unit
Sensitivity
4P AC
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
AUF3C401603
AUF3C401610
AUF3C401630
AUF3C402003
AUF3C402010
AUF3C402030
AUF3C402503
AUF3C402510
AUF3C402530
AUF3C403203
AUF3C403210
AUF3C403230
AUF3C404003
AUF3C404010
AUF3C404030
AUF3C406303
AUF3C406310
AUF3C406330
4185
4675
4770
4185
4675
4770
4185
4475
4605
4320
4520
4605
4385
4655
4700
5230
5330
5330
6A
10A
Rating Module CAT Nos.M.R.P.
(`)Per Unit
Sensitivity
2P Adi
30mA
100mA
300mA
30mA
100mA
300mA
2
2
2
2
2
2
AUF3D200603
AUF3D200610
AUF3D200630
AUF3D201003
AUF3D201010
AUF3D201030
7170
7325
7600
7170
7325
7600
Rating Module CAT Nos.M.R.P.
(`)Per Unit
Sensitivity
2P Adi
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
AUF3D201603
AUF3D201610
AUF3D201630
AUF3D202003
AUF3D202010
AUF3D202030
AUF3D202503
AUF3D202510
AUF3D202530
AUF3D203203
AUF3D203210
AUF3D203230
AUF3D204003
AUF3D204010
AUF3D204030
7325
7600
7170
7325
7600
7170
7325
7600
7170
7325
7600
7170
7325
7600
7170
10
RCCBs (Residual Current Circuit Breakers) [8536]
• Wide Range of Current Ratings - 25A to 100A
• Precise Sensitivities for variety of applications - from 30mA to 300mA
• 2P & 4P versions
• Suitable for Isolation
• Protection Degree - IP 20
• Availability of wide Range of Site Mountable Accessories
CAT Nos.M.R.P.
(`)Per Unit
VoltageModuleDescription Configuration
Auxiliary Contact 1NO+1NC
1NO+1NC
0.5
0.5
1
1
1
1
1
240V AC, 24V DC
240V AC, 24V DC
240V AC
24V DC
240V AC
240V AC
24V DC
AUAXAC240
AUATAC240
AUUVAC240
AUUVDC024
AUOVAC240
AUSRAC240
AUSRDC024
730
860
1750
1750
2150
2000
2000
AUX/TAC*
Overvoltage Release
Shunt Release
400
450
Padlock-Suitable for Lock Hasp
3.5 - 5 mm dia. max
Suitable for 1Pole=1Mod devices: RCCBs, RCBOs, Changeover Switches up to 40A AUPD01
AUPD02Suitable for 1Pole-1.5Mod devices:
MCBs 80A-125A, Changeover Switch 63A
Undervoltage
Release
-
-
-
-
-
Note: Standard Pack Quantity for Padlock - 2Nos.* For 80A-125A MCBs please contact nearest L&T branch
All Half Module and One Module Accessories are common for 80A-125A MCBs, RCBOs and Adi RCCBs
Accessories [8538]
Type-Adi (with Added immunity)
Rating Module CAT Nos.M.R.P.
(`)Per Unit
Sensitivity
2
2
2
2
2
2
2
2
2
2
2P Adi
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
AURAD202503
AURAD202510
AURAD202530
AURAD204003
AURAD204010
AURAD204030
AURAD206303
AURAD206310
AURAD206330
AURAD210003
5220
5460
5460
5545
5630
5630
5710
5825
5825
6650
25A
40A
63A
100A
4P Adi
30mA
100mA
300mA
30mA
100mA
300mA
30mA
100mA
300mA
30mA
300mA
4
4
4
4
4
4
4
4
4
4
4
AURAD402503
AURAD402510
AURAD402530
AURAD404003
AURAD404010
AURAD404030
AURAD406303
AURAD406310
AURAD406330
AURAD410003
AURAD410030
5915
6030
6030
6135
6245
6245
6295
6425
6425
8500
8500
11
25A
40A
63A
100A
New Range of Distribution Boards
Complete range of Distribution Boards
is RoHS compliant
Protection against Mechanical Impact (IK)
Ensures Distribution Boards and
Enclosures are well protected from
external impact
Certification
Conforms to IS 8623-1 & 3,
IEC 61439 - 1 & 3
Ingress Protection (IP) Test certificate
Ensures Distribution Boards and
Enclosures are well protected against
external foreign bodies & liquid (Restriction of Hazardous Substances)
12
Customer Benefits
In order to adapt to site condition, DB door can be reversed at the site
DB Installation made convenient with independently removable door, shield, frame & chassis
The removal of the chassis, with the neutral bar mounted on it offers immense flexibility during commissioning
Product mounting and wiring made easy as the products can be conveniently mounted on the chassis and entire assembly can be easily fitted in the DB box with chassis that can be stored separately
To avoid unauthorized access to a DB and ensure safety during maintenance, DBs are equipped for installing a special latch with a key lock provision
Flush mounting of a DB made easy and perfect fit is achieved with clearly visible anti insertion marking
13
Customer Benefits
No accidental contact with live parts is ensured with
Transparent shrouds for neutral bars
High quality insulation on bus-bars
Assured level of Ingress Protection (IP) with the help of high quality gaskets in double door DBs
Protection of DB interiors from cement splashes during civil activities with cement spill protector
Ease of wiring is facilitated with removable top and bottom gland plates with adequate number of cut and carry knockouts
Removing of shield made easy with ergonomically designed holding shield knobs
14
Customer Benefits
Customized Distribution Boards
Distribution Boards with factory fitted phase and neutral terminal blocks for termination of incoming and outgoing wires
Available in both Single Phase and Three Phase DB versions
Distribution Boards equipped with provisions to mount TV-Telephone splitters
Available in both Single phase and Three phase DB versions
Distribution Boards with phase segregation between incomer, sub incomer, outgoings and supply changeover sections
Distribution Boards with inbuilt auto-manual switches
Available in both Single phase and Three phase DB versions
DB carton Separate packinginside
For Door, Frameand Shield
Complete safety is ensured by effective earthingthroughout the distribution board with star washers
Independently packed 'door-frame-shield' ensures- - Separate and safe storage at site - No damage during civil activities
Safe, neat and clutter-free wiring is facilitated with adequate space for wiring
15
Highlights
•
•
•
•
IK 08-for single door DBs, IK 09-for double door DBs
Available in CRCA sheet steel, RAL9003, powder coated
Ready to use DBs - Provided with100A insulated phase bus-bar | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification label
With provision for DP MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoings
Highlights
•
•
•
•
IK 08-for single door DBs, IK 09-for double door DBs
Available in CRCA sheet steel, RAL 9003, powder coated
Ready to use DBs - Provided with 100A insulated phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels
With provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoings
SPN DB [8537] TPN DB [8537]
No. of Modules
Incomer Outgoing
No. of Modules
Incomer OutgoingCat. Nos. Cat. Nos.
M.R.P. (`)
Per UnitDescription
6 way
8 way
12 way
16 way
18 way
4 way
6 way
8 way
12 way
16 way
18 way
4 way
6 way
8 way
12 way
16 way
18 way
4 way
6 way
8 way
12 way
16 way
18 way
4 way
IP 30 - Single Door
IP 43 - Metal Door
IP 43 - Glazed Door
IP 54 - Metal Door
2
4
6
10
14
16
2
4
6
10
14
16
2
4
6
10
14
16
2
4
6
10
14
16
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
8
8
8
8
8
4
4
8
8
8
8
8
4
4
8
8
8
8
8
4
4
8
8
8
8
8
975
1060
1215
1440
1775
2295
1325
1525
1640
1980
2480
3300
1680
1800
1965
2375
2940
3445
4200
4685
4940
5705
6315
6765
DBSPN004SD
DBSPN006SD
DBSPN008SD
DBSPN012SD
DBSPN016SD
DBSPN018SD
DBSPN004DD
DBSPN006DD
DBSPN008DD
DBSPN012DD
DBSPN016DD
DBSPN018DD
DBSPN004GD
DBSPN006GD
DBSPN008GD
DBSPN012GD
DBSPN016GD
DBSPN018GD
DBSPN00454
DBSPN00654
DBSPN00854
DBSPN01254
DBSPN01654
DBSPN01854
DBTPE004SD
DBTPE006SD
DBTPN004SD
DBTPN006SD
DBTPN008SD
DBTPN012SD
DBTPN016SD
DBTPE004DD
DBTPE006DD
DBTPN004DD
DBTPN006DD
DBTPN008DD
DBTPN012DD
DBTPN016DD
DBTPE004GD
DBTPE006GD
DBTPN004GD
DBTPN006GD
DBTPN008GD
DBTPN012GD
DBTPN016GD
DBTPE00454
DBTPE00654
DBTPN00454
DBTPN00654
DBTPN00854
DBTPN01254
DBTPN01654
2515
3090
2700
3330
3920
5805
7150
3085
3810
3290
4060
4865
7285
8985
3955
4880
4215
5200
6235
9570
11485
9555
11785
10060
12110
13245
18665
22405
M.R.P. (`)
Per UnitDescription
IP 30 - Single Door
IP 43 - Metal Door
IP 43 - Glazed Door
IP 54 - Metal Door
6 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
4 way
6 way
8 way
12 way
16 way
4 way 4+4+4
6+6+6
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door
16
PPI DB [8537] TPN Phase Segregated DB [8537]
Horizontal PPI DBs
Tier PPI DBs
With Modular Incomer
With MCCB Incomer
No. of Modules M.R.P. (`)
Per Unit
Description
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way
Incomer Sub-Incomer
Outgoing
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
8
8
8
8
8
8
8
8
8
8
DBHPI004DD
DBHPI006DD
DBHPI008DD
DBHPI012DD
DBHPI016DD
DBHPI00454
DBHPI00654
DBHPI00854
DBHPI01254
DBHPI01654
5065
6050
7190
9830
11800
11880
14155
15635
21338
25375
IP 43 - Metal Door
IP 54 - Metal Door
No. of Modules M.R.P. (`)
Per Unit
Description
4 way
6 way
8 way
12 way
4 way
6 way
8 way
12 way
4 way
6 way
8 way
12 way
Incomer Sub-Incomer
Outgoing
4+4+4
6+6+6
8+8+8
12+12+12
4+4+4
6+6+6
8+8+8
12+12+12
4+4+4
6+6+6
8+8+8
12+12+12
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
8
8
8
8
8
8
8
8
8
8
8
8
DBPSG004SD
DBPSG006SD
DBPSG008SD
DBPSG012SD
DBPSG004DD
DBPSG006DD
DBPSG008DD
DBPSG012DD
DBPSG00454
DBPSG00654
DBPSG00854
DBPSG01254
7545
8230
8820
10150
8170
9210
10275
13120
14030
15800
17650
22520
IP 30 - Single Door
IP 43 - Metal Door
IP 54 - Metal Door
No. of Modules M.R.P. (`)
Per Unit
Description
4 way
6 way
8 way
12 way
4 way
6 way
8 way
12 way
4 way
6 way
8 way
12 way
Incomer* Sub-Incomer
Outgoing
4+4+4
6+6+6
8+8+8
12+12+12
4+4+4
6+6+6
8+8+8
12+12+12
4+4+4
6+6+6
8+8+8
12+12+12
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
4+4+4
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
DBPGL004SD
DBPGL006SD
DBPGL008SD
DBPGL012SD
DBPGL004DD
DBPGL006DD
DBPGL008DD
DBPGL012DD
DBPGL00454
DBPGL00654
DBPGL00854
DBPGL01254
10895
12540
14405
16725
12245
14005
16045
18270
20810
23805
27270
31055
IP 30 - Single Door
IP 43 - Metal Door
IP 54 - Metal Door
Highlights
•
•
•
•
IK 08-for single door DBs. IK 09-for double door DBs
Available in CRCA sheet steel, RAL 9003, powder coated
Ready to use DBs - Provided with 100A insulated phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels
With provision for 1. Modular Incomer - FP MCB/Isolator as incomer, DP RCCB/RCBO as sub-incomer and SP MCBs as outgoings
2. MCCB Incomer - TP/FP DU100H MCCB as incomer, DP RCCB/RCBO as sub-incomer and SP MCBs as outgoings
No. of Modules M.R.P. (`)
Per UnitDescription
6 way
8 way
10 way
12 way
16 way
12 way
6 way
8 way
10 way
12 way
16 way
12 way
Incomer Sub-Incomer
Outgoing
6+6+6
8+8+8
10+10+10
12+12+12
16+16+16
12+12+12
6+6+6
8+8+8
10+10+10
12+12+12
16+16+16
12+12+12
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
2+2+2
8
8
8
8
8
MCCB*
8
8
8
8
8
MCCB*
DBTPI006DD
DBTPI008DD
DBTPI010DD
DBTPI012DD
DBTPI016DD
DBTPL012DD
DBTPI00654
DBTPI00854
DBTPI01054
DBTPI01254
DBTPI01654
DBTPL01254
7185
9015
9455
10285
10830
10715
11850
14875
15605
16970
17870
17685
IP 43 - Metal Door
IP 54 - Metal Door
*Suitable for 3 pole and 4 pole DU100H MCCB as incomer
*Suitable for 3 pole and 4 pole DU100H MCCB as incomer
IP 43 - Metal Door IP 30 - Single Door IP 43 - Metal Door
IP 43 - Metal Door IP 30 - Single Door IP 43 - Metal Door
Highlights
•
•
•
•
IK 09-for double door DBs
Available in CRCA sheet steel, RAL 9003, powder coated
Ready to use DBs - Provided with 100A insulated phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels
With provision for FP MCB/Isolator/RCCB/RCBO/ as incomer, DP RCCB/RCBO as sub-incomer and SP MCBs as outgoings
Cat. Nos.Cat. Nos.
Cat. Nos.Cat. Nos.
17
TPN Phase Selector DB [8537] Flexi/Row DB [8537]
3445
4135
4735
5320
3665
4400
5040
5660
4300
5270
5975
6555
6775
8380
9130
10080
DBROW228SD
DBROW342SD
DBROW456SD
DBROW464SD
DBROW228DD
DBROW342DD
DBROW456DD
DBROW464DD
DBROW228GD
DBROW342GD
DBROW456GD
DBROW464GD
DBROW22854
DBROW34254
DBROW45654
DBROW46454
No. of Modules M.R.P. (`)
Per Unit
DescriptionIncomer Outgoing
6 way
8 way
10 way
12 way
4 way
6 way
8 way
10 way
12 way
4 way
6 way
8 way
10 way
12 way
4 way 8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
4+4+4
6+6+6
8+8+8
10+10+10
12+12+12
4+4+4
6+6+6
8+8+8
10+10+10
12+12+12
4+4+4
6+6+6
8+8+8
10+10+10
12+12+12
10445
11105
12305
12765
13510
11625
11815
12655
13520
14255
15575
15825
16960
18115
19095
DBPSR004SD
DBPSR006SD
DBPSR008SD
DBPSR010SD
DBPSR012SD
DBPSR004DD
DBPSR006DD
DBPSR008DD
DBPSR010DD
DBPSR012DD
DBPSR00454
DBPSR00654
DBPSR00854
DBPSR01054
DBPSR01254
IP 30 - Single Door
IP 43 - Metal Door
IP 54 - Metal Door
M.R.P. (`)
Per UnitDescription No. of Modules
Per Row
IP 30 - Single Door
IP 43 - Metal Door
IP 43 - Glazed Door
IP 54 - Metal Door
2 Row 28 Module
3 Row 42 Module
4 Row 56 Module
4 Row 64 Module
2 Row 28 Module
3 Row 42 Module
4 Row 56 Module
4 Row 64 Module
2 Row 28 Module
3 Row 42 Module
4 Row 56 Module
4 Row 64 Module
2 Row 28 Module
3 Row 42 Module
4 Row 56 Module
4 Row 64 Module
14
14
14
16
14
14
14
16
14
14
14
16
14
14
14
16
Highlights
•
•
•
•
IK 08-for single door DBs, IK 09-for double door DBs
Available in CRCA sheet steel, RAL 9003, powder coated
Ready to use DBs - Provided with 3 nos. of 63A Salzer rotary switches | 3 nos. of rocker switches for phase identification | 100A insulated phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels
With provision for - FP MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoings
Highlights
•
•
•
•
IK 08-for single door DBs, IK 09-for double door DBs
Available in CRCA sheet steel, RAL 9003, powder coated
Ready to use DBs - neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | cable ties | blanking plates and circuit identification labels
With provision to mount modular devices as per requirement
IP 30 - Single Door IP 43 - Metal Door IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door
Highlights
• Available in One module and Half module
Blanking Plates [8538]
M.R.P. (`)
Per UnitDescription
One Module
Half Module
BKP10
BKP05
15
15
10
10
Std.PackQty.
Cat. Nos.Cat. Nos.
Cat. Nos.
DB Accessories
Highlights
•
•
•
Conforms to IEC 61439-3
Available in Single Pole, Double Pole, Three Pole and Four Pole versions
Material : Copper
Busbar - Fork Type [8538]
M.R.P. (`)
Per UnitDescription
SP 13 Mod
SP 56 Mod
DP 12 Mod
TP 12 Mod
FP 12 Mod
End Caps for SP
End Caps for DP/TP
End Caps for FP
BSP13
BSP56
BDP12
BTP12
BFP12
ECP01
ECP03
ECP04
Std.PackQty.
265
995
435
465
975
8
25
35
5
5
5
5
5
10
10
10
Cat. Nos.
M.R.P. (`)
Per UnitDescription
PDK02Lock and Key Kit 425 5
Std.PackQty.
Highlights
• Version with standard lock and a common key
Padlock [8301]
PDK02
Cat. Nos.
18
Vertical TPN DB with Modular Incomer [8537] Vertical TPN DB with MCCB Incomer [8537]
Up to 125A MCCB Incomer
M.R.P. (`)
Per Unit
DescriptionNo. of Modules
Incomer Outgoing
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way 4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
7480
8185
9130
13185
15250
8015
9805
10745
14865
17545
10700
11430
13605
18150
19270
16145
18140
19420
25875
27400
DBVTM004SD
DBVTM006SD
DBVTM008SD
DBVTM012SD
DBVTM016SD
DBVTM004DD
DBVTM006DD
DBVTM008DD
DBVTM012DD
DBVTM016DD
DBVTM004GD
DBVTM006GD
DBVTM008GD
DBVTM012GD
DBVTM016GD
DBVTM00454
DBVTM00654
DBVTM00854
DBVTM01254
DBVTM01654
IP 30 - Single Door
IP 43 - Metal Door
IP 43 - Glazed Door
IP 54 - Metal Door
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
)8
8
8
8
8
M.R.P. (`)
Per Unit
DescriptionNo. of Modules
Incomer* Outgoing
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way 4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
DBVTL004SD
DBVTL006SD
DBVTL008SD
DBVTL012SD
DBVTL016SD
DBVTL004DD
DBVTL006DD
DBVTL008DD
DBVTL012DD
DBVTL016DD
DBVTL004GD
DBVTL006GD
DBVTL008GD
DBVTL012GD
DBVTL016GD
DBVTL00454
DBVTL00654
DBVTL00854
DBVTL01254
DBVTL01654
IP 30 - Single Door
IP 43 - Metal Door
IP 43 - Glazed Door
IP 54 - Metal Door
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
Highlights
•
•
•
•
IK 08-for single door DBs, IK 09-for double door DBs
Available in CRCA sheet steel, RAL 9003, powder coated
Ready to use DBs - Provided with insulated vertical phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels
With provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCBs as outgoings
Highlights
•
•
•
•
IK 08-for single door DBs, IK 09-for double door DBs
Available in CRCA sheet steel, RAL 9003, powder coated
Ready to use DBs - Provided with insulated vertical phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels
With provision for MCCB* as incomer and SP/TP MCBs as outgoings
*Suitable for 3 pole and 4 Pole MCCB as incomer
A) Up to 125A - DU100H, DU125H (Icu = 30kA, Ics =50% Icu)
B) Up to 250A - DU250 (Icu = 36kA , Ics = 50% Icu)
*Suitable for 3 pole and 4 pole DU100H, DU125H MCCB as incomer
IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door
8580
9325
10155
15360
18170
9610
11030
12080
16075
18545
10810
12250
13820
18425
20395
18580
19925
22335
28190
33735
Cat. Nos.Cat. Nos.
19
No. of Pins
No. of Modules
M.R.P. (`)
Per Unit
Description
Up to 250A MCCB Incomer
Vertical TPN DB with MCCB Incomer [8537] Plug & Socket DB [8537]
No. of PinsM.R.P.
(`)Per Unit
Description
Metal Plug [8536]
Metal Socket [8536]
M.R.P. (`)
Per Unit
DescriptionNo. of Modules
Incomer* Outgoing
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way
6 way
8 way
12 way
16 way
4 way 4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
4+4+4
6+6+6
8+8+8
12+12+12
16+16+16
10530
11050
12155
17170
20690
11875
13490
14830
19855
23580
19600
21990
22870
24100
25935
26450
28880
29870
34975
36810
DBVTH004SD
DBVTH006SD
DBVTH008SD
DBVTH012SD
DBVTH016SD
DBVTH004DD
DBVTH006DD
DBVTH008DD
DBVTH012DD
DBVTH016DD
DBVTH004GD
DBVTH006GD
DBVTH008GD
DBVTH012GD
DBVTH016GD
DBVTH00454
DBVTH00654
DBVTH00854
DBVTH01254
DBVTH01654
IP 30 - Single Door
IP 43 - Metal Door
IP 43 - Glazed Door
IP 54 - Metal Door
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
10 A, 2 Pin + SC^
20 A, 2 Pin + SC^
20 A, 2 Pin + SC^
20 A, 3 Pin + SC^
32 A, 3 Pin + SC^
32 A, 3 Pin + SC^
63 A, 5 Pin + SC^
16 A, 3 Pin
32 A, 3 Pin
32 A, 5 Pin
63 A, 5 Pin
P + N
P + N
P + N
3P
3P
3P
3P+N+E
P+N+E
P+N+E
3P+N+E
3P+N+E
1
1
2
3
3
4
4
2
4
8
8
Metal Plug & Sockets
Plastic Plug & Sockets
1305
1405
1530
2595
3070
3260
11085
2115
2285
4160
10580
DBMPS110SD
DBMPS120SD
DBMPS220SD
DBMPS320SD
DBMPS332SD
DBMPS432SD
DBMPS463SD
DBPPS316SD
DBPPS332SD
DBPPS532SD
DBPPS563SD
10 A, 2 Pin + SC^
20 A, 2 Pin + SC^
20 A, 3 Pin + SC^
32 A, 3 Pin + SC^
P + N
P + N
3P
3P
135
145
190
360
MPS210P
MPS220P
MPS320P
MPS332P
No. of PinsM.R.P.
(`)Per Unit
Description
10 A, 2 Pin + SC^
20 A, 2 Pin + SC^
20 A, 3 Pin + SC^
32 A, 3 Pin + SC^
P + N
P + N
3P
3P
140
160
210
360
MPS210S
MPS220S
MPS320S
MPS332S
Highlights
•
•
•
Sutable for Surface and Flush mounting
Available in CRCA sheet steel RAL9003 powder coated
Loose Metal Plugs & Sockets conforms to IS 8804; available in Single Phase & Three Phase
*Suitable for 3 pole and 4 pole DU250 MCCB as incomer
SC-Scraping Earth
IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door
Metal Plug & Socket Plastic Plug & Socket
Enclosure [8537]
No. of ModulesM.R.P.
(`)Per Unit
Description
IP 30 - Metal Door
3 way
4 way
6 way
2 way
3
4
6
2 DBENC002SD
DBENC003SD
DBENC004SD
DBENC006SD
505
505
505
765
Highlights
•
•
•
Sutable for Surface and Flush mounting
Available in CRCA sheet steel RAL9003 powder coated
With provision to mount MCB/Isolator/RCCB/RCBO and other modular devices
IP 30 - Metal Door
Cat. Nos.
Cat. Nos.
Cat. Nos.
Cat. Nos.Cat. Nos.
20
Highlights
•
•
Available in CRCA sheet steel RAL9003 powder coated
Can be either at the top or bottom of the distribution board
Cable End Boxes [8537]
M.R.P. (`)
Per Unit
Description
CEB-SPN Double Door, 4 way
CEB-SPN Double Door, 6 way
CEB-SPN Double Door, 8 way
CEB-SPN Double Door, 12 way
CEB-SPN Double Door, 16 way
CEB-SPN Double Door, 18 way
CEB-TPN Double Door, 4 way
CEB-TPN Double Door, 6 way
CEB-TPN Double Door, 8 way
CEB-TPN Double Door, 12 way
CEB-TPN Double Door, 16 way
CEB-TPE Double Door, 4 way
CEB-TPE Double Door, 6 way
CEB-Horz. PPI Double Door, 4 way
CEB-Horz. PPI Double Door, 6 way
CEB-Horz. PPI Double Door, 8 way
CEB-Horz. PPI Double Door, 12 way
CEB-Horz. PPI Double Door, 16 way
CEB-Tier PPI Double Door, 6 way
CEB-Tier PPI Double Door, 8 way
CEB-Tier PPI Double Door, 10 way
CEB-Tier PPI Double Door, 12 way
CEB-Tier PPI Double Door, 16 way
CEB-Tier PPI Double Door, 12 wayMCCB incomer
CEB for SPN DBs
CEB for TPN DBs
CEB for Horizontal PPI DBs
CEB for Tier PPI DBs
DBSPN004CB
DBSPN006CB
DBSPN008CB
DBSPN012CB
DBSPN016CB
DBSPN018CB
DBTPN004CB
DBTPN006CB
DBTPN008CB
DBTPN012CB
DBTPN016CB
DBTPE004CB
DBTPE006CB
DBHPI004CB
DBHPI006CB
DBHPI008CB
DBHPI012CB
DBHPI016CB
DBTPI006CB
DBTPI008CB
DBTPI010CB
DBTPI012CB
DBTPI016CB
DBTPL012CB
570
605
675
755
1045
1115
950
1205
1860
2420
2445
890
1115
1095
1245
1465
1640
1850
1035
1080
1310
1605
1710
1625
Cat. Nos.M.R.P.
(`)Per Unit
Description .Cat. Nos.
DBVTMXXXCB
DBVTXXXXCB
DBROWX14CB
DBROWX16CB
DBPSG004CB
DBPSG006CB
DBPSG008CB
DBPSG012CB
DBPSR004CB
DBPSR006CB
DBPSR008CB
DBPSR010CB
DBPSR012CB
730
2630
850
965
1625
1935
2140
2380
820
930
1510
1745
1890
CEB-VTPN Double Door, Modular Incomer
CEB-VTPN Double Door, MCCB Incomer
CEB-PSG Double Door, 4 way
CEB-PSG Double Door, 6 way
CEB-PSG Double Door, 8 way
CEB-PSG Double Door, 12 way
CEB-Phase Selector Double Door, 4 way
CEB-Phase Selector Double Door, 6 way
CEB-Phase Selector Double Door, 8 way
CEB-Phase Selector Double Door, 10 way
CEB-Phase Selector Double Door, 12 way
CEB for VTPN DBs
CEB for FLEXI DBs
CEB for Phase Segregated DBs
CEB for Phase Selector DBs
CEB for Flexi DBs with 14 Modules per Row
CEB for Flexi DBs with 16 Modules per Row
21
Distribution Board (DB) Selection Guide
SPN
TPN
TPN - Horizontal PPI
TPN - Tier PPI
VTPN Modular Incomer
VTPN MCCB Incomer
TPN - Phase Segregated
(7 Segment)
TPN - Phase Selector
Flexi / Row
Enclosure
Plug & Socket
- For single phase supply distribution
- For three phase supply distribution
- For three phase supply distribution in Horizontal disposition
- Isolation between phases is achieved with leakage protection device as sub-incomer and separate neutral bar for individual phases (PPI - Per Phase Isolation)
- In case one of the circuits experiences earth leakage fault in a specific phase, sub-incomer of that phase trips leaving other phases operate normally
- For three phase supply distribution in Tier/Vertical disposition
- Isolation between phases is achieved with leakage protection device as sub-incomer and separate neutral bar for individual phases (PPI - Per Phase Isolation)
- In case one of the circuits experiences earth leakage fault in a specific phase, sub-incomer of that phase trips leaving other phases operate normally
- For three phase supply distribution (Vertical TPN)
- For sites with constraint on mounting DB of higher width
- Higher rating (125A) of incomer and corresponding bus bar
- Combination of single phase and three phase outgoing MCBs
- DBs come with PAN assembly for ready installation of incomer and outgoing devices
- For three phase supply distribution
- For sites with constraint on mounting DB of higher width
- Combination of single phase and three phase outgoing MCBs
- For MCCB as incomer (with current rating up to 250A) with typically higher breaking capacity than that of an MCB
- DBs come with PAN assembly for ready installation of incomer and outgoing devices
- For three phase supply distribution
- Isolation between phases is achieved with leakage protection device as sub-incomer and separate neutral bar for individual phases
- Physical separation between outgoing phases, phase sub-incomer and main incomer
- Owing to compartmental design, any of the sections can be individually opened
- For three phase supply distribution
- To maintain continuity of supply to a critical load by switching over to live phase temporarily
- Choice of either single phase or three phase supply distribution
- Choice of number of modules for incoming and outgoing as per specific requirement
- Choice of installing monitoring and control devices
- Enclosure for modular devices
- Providing protection to standalone single phase and three phase loads
23
All prices are on maximum retail price basis inclusive ofall Duties, GST and any other Tax as applicable.
Prices are subject to revision without notice.
All the products listed in the price list carry a warranty, against manufacturing defects for a period of 18* months from the date of purchase.
Should the product prove to be defective due to faulty workmanship or otherwise, we will remedy the defect or replace the faulty parts or the whole product at our discretion, as soon as possible, free of cost.
The warranty is however subject to the provision of proper usage, efficient maintenance and does not cover defects arising out of fire, accident, inefficient maintenance, faulty operation and willful or accidental damage. It also does not cover damage to power electronic components like thyristors & IGBTs, which fail predominantly due to over-temperature & over-voltage. The user needs to take adequate precautions to eliminate these conditions. The manufacturer shall not be liable for any consequential loss, injury or damages attributable to defect or failure of its products.
L&T has over five decades of experience in providing after sales service for low voltage distribution systems in every type of industry & commercial complex in India.
L&T offers the following services, partnering you in your maintenance of low voltage distribution products :
Regular Maintenance
Preventive Maintenance Programme
On Call
Annual Maintenance Contract
Product Support for Managing Obsolescence -
Retrofitting & Upgradation of your switchgear products.
•
•
•
•
•
SP
50580 R
11
Khairasol, Degaul AvenueDurgapur 713 212Tel: 0343-2540448 / 2540449 / 2540443Fax: 0343-2540442e-mail: [email protected]
5, Milanpur Road, Bamuni MaidanGuwahati 781 021Tel: +91 8876554410 / 8876554417Fax: 361-2551308e-mail: [email protected]
II Floor, Vasantha Chambers5-10-173, Fateh Maidan RoadHyderabad 500 004Tel: 040-67015052Fax: 040-23296468e-mail: [email protected]
Monarch Building, 1st FloorD-236 & 237, Amrapali MargVaishali NagarJaipur 302 021Tel: 0141-4385914 to 18Fax: 0141-4385925e-mail: [email protected]
Akashdeep Plaza, 2nd FloorP. O. GolmuriJamshedpur 831 003JharkhandTel: 0657-2312205 / 38Fax: 0657-2341250e-mail: [email protected]
Skybright Bldg; M. G. RoadRavipuram Junction, ErnakulamKochi 682 016Tel: 0484-4409420 / 4 / 5 / 7Fax: 0484-4409426e-mail: [email protected]
3-B, Shakespeare SaraniKolkata 700 071Tel: 033-42005982Fax: 033-22821025 / 7587e-mail: [email protected]
A28, Indira Nagar, Faizabad Road Lucknow 226 016Tel: 0522-4929905 / 04Fax: 0522-2311671e-mail: [email protected]
No: 73, Karpaga Nagar, 8th StreetK. PudurMadurai 625 007Tel: 0452-2567405 / 2561068 / 2561657Fax: 0452-2567552e-mail: [email protected]
Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.Product photographs shown are for representative purpose only.
Electrical Standard Products (ESP) Offices:
HEAD OFFICEL&T Business Park,Tower 'B' / 3rd FloorSaki Vihar Road, PowaiMumbai 400 072Tel: 022-67053229 Fax: 022-67051112e-mail: [email protected]
BRANCH OFFICES501, Sakar Complex I Opp. Gandhigram Rly. Station Ashram RoadAhmedabad 380 009Tel: 079-66304006-11Fax: 079-66304025e-mail: [email protected]
38, Cubbon Road, P. O. Box 5098Bengaluru 560 001Tel: 080-25020100 / 25020324Fax: 080-25580525e-mail: [email protected]
131/1, Zone IIMaharana Pratap NagarBhopal 462 011Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Fax: 0755-3080502e-mail: [email protected]
Plot No. 559, Annapurna ComplexLewis RoadBhubaneswar 751 014Tel: 0674-6451342 / 2436690 / 2436696Fax: 0674-2537309e-mail: [email protected]
Aspire Towers, 4th FloorPlot No. 55, Phase-IIndustrial & Business ParkChandigarh-160 002Tel: 0172-4646840 / 41 / 42 / 46 / 53Fax: 0172-4646802Email: [email protected]
L&T Construction CampusTC-1 Building, II FloorMount-Poonamallee RoadManapakkamChennai 600 089Tel: 044-2270 6800Fax: 044-22706940e-mail: [email protected]
67, Appuswamy RoadPost Bag 7156 Opp. Nirmala CollegeCoimbatore 641 045Tel: 0422-2588120 / 1 / 5Fax: 0422-2588148e-mail: [email protected]
L&T Business Park,Tower 'B' / 5th FloorSaki Vihar Road, PowaiMumbai 400 072Tel: 022-67052874 / 2737 / 1156Fax: 022-67051112e-mail: [email protected]
12, Shivaji NagarNorth Ambajhari RoadNagpur 440 010Tel: 0712-2260012 / 6606421Fax: 2260030 / 6606434e-mail: [email protected]
32, Shivaji Marg P. O. Box 6223New Delhi 110 015Tel: 011-41419514 / 5 / 6Fax: 011-41419600e-mail: [email protected]
L&T House P. O. Box 119 191/1, Dhole Patil RoadPune 411 001Tel: 020-66033395 / 66033279Fax: 020-26164048 / 26164910e-mail: [email protected]
Crystal Tower, 4th Floor, G. E. RoadTelibandhaRaipur - 492 006Tel: 0771-4283214e-mail: [email protected]
3rd Floor Vishwakarma ChambersMajura Gate, Ring RoadSurat 395 002Tel: 0261-2473726Fax: 0261-2477078e-mail: [email protected]
Radhadaya ComplexOld Padra RoadNear Charotar SocietyVadodara 390 007Tel: 0265-6613610 / 1 / 2Fax: 0265-2336184e-mail: [email protected]
Door No. 49-38-14/3/2, 1st floor,NGGO's Colony, Akkayyapalem,Visakhapatnam - 530 016Tel: 0891-2791126 / 2711125Fax: 0891-2791100Email: [email protected]
Larsen & Toubro Limited, Electrical Standard ProductsPowai Campus, Mumbai 400 072
Customer Interaction Center (CIC)BSNL / MTNL (toll free) : 1800 233 5858 Reliance (toll free) : 1800 200 5858Tel : 022 6774 5858, Fax : 022 6774 5859 E-mail : [email protected] / Website www.Lntebg.com
Registered Office: L&T House, N. M. Marg, Ballard Estate, Mumbai 400 001, INDIA CIN: L99999MH1946PLC004768