0029 Cert. N°: 09/BE/1814 ISO 13485 (2003) BODYBOX 5500 ® Barometric total bodyplethysmograph EXPAIR software The MediSoft factory is a state of the art modern facility with clinical research, precision engineering and computer design departments. GENERAL SPECIFICATIONS Dim. Standard Double Door/XL Paediatric (H x W x D) cm 176x87x71 179x120x83 140x66x55 Weight ± 130 kg ± 150 Kg ± 105 Kg Internal Volume 960 L ± 1250 L ± 450 L Patient chair Pneumatic adjustement BodyBox closing door Sturdy closing and internal handle Power requirements 230/115 VAC 50/60 Hz Power Consumption 100 VA (module) Warm up Time 20 min (minimum) Conform to electrical safety req. IEC60601/1 and CE 0029 BODYBOX 5500 PATIENT VALVE Pneumotachograph Lilly cone Range 0,03 to 15 L/sec or 20L/sec Résistance 0,4 cmH 2 O/L/sec Relative accuracy Error < 3% Volume conv. to BTPS integrated thermometer (optional barometer) Automatic zero shift correction of measuring elements Software computerised linearization Patient valve Pneumatic (Time O/C : 30 mS ) Dead Space < 60 ml / 30 ml (paediatric). DisinfectionSimple Dismantling for cold cleaning Valve Support Arm Moveable arm with 3 joints PRESSURE TRANSDUCERS Piezo resistive sensors protected from overload Sensitivity Resolution Calibration Box pres ± 0,5 cm H2 O Box Pres 0,05 cm H 2 O Box Pres Integrated 30ml pump Mouth pres ± 50,0 cm H 2 O Mouth Pres. & Flow 0,01 cm H 2 O Mouth Pres. Water column Pres. MIP/MEP SNIP ± 280,0 cm H 2 O Linearity Error < 0,1% Pneumotachograph semi. auto. with 1 to 3L Mouth flow ± 5,0 cm H 2 O Relative Accuracy Error < 0,01% syringe with ERS/ATS quality control indicator GAS ANALYZERS Helium Thermal conductivity Range 0 to 15% He Relative accuracy ± 0,1% Response time ± 200 msec Fast He ± 10 sec He STD Carbon monoxide infra red/Fast or Fuel Cell Range 0 to 0,350 % CO Relative accuracy ± 0,1 % Response time ± 150 msec Fast CO ± 20 sec CO Fuel Cell O 2 Chemical Fuel Cell Range 0 to 100 % O 2 Relative accuracy ± 0,02 % Response time ± 150 msec CO 2 infra red Range 0 to 10 % CO 2 Relative accuracy ± 0,01 % Response time ± 120 msec OPTIONAL GAS ANALYZERS Multigas analyser Infrared spectrometer (CO, CH4, CO 2, C 2 H 2 ) Range 0 to 0,350%, CO 2 : 0 -10% Relative accuracy ± 0,1 % Response time < 20 sec (10 - 90% FS) Nitric oxide Chemical fuel cell Range 0 - 450 ppm Relative accuracy ± 0,1 % Response time < 10 sec (10 - 90 % Fs) GAS SUPPLY SPECIFICATIONS Body Box Compressed air TLCO He option 0,3% CO, 14% He, 21% O 2 , rem N 2 TLNO option ± 450 ppm No, rem N 2 TLCO CH 4 option 0,3% CO, 0,3% CH 4 , 21% O 2 , rem N 2 Pressure regulator 0 - 8 Bars / 15 m 3 /h TLCO ss 0,08 CO, 21% O 2 rem N 2 FRC N 2 100% O 2 ANALYSER CIRCUIT Automatic, rapid and accurate calibration with quality control VOLUMETRIC BODYBOX (OPTION) Pneumotachograph double Grid Lilly cone Range 0,01 to 15 L/sec Resistance 0,1cm H2O/L/sec Relative accuracy Error < 3% COMPUTER INTERFACE Type Serial RS232 or USB Conversion 12 & 16 bit. Acq. frequency 100 Hz /chanels (Multigas 3500 Hz) Transmission speed 115,200 baud Isolation System fully isolated by optocoupling Computer PC Intel, 19’’ monitor, Printer A4 colour Deskjet Operating system Windows 7 ® 32 or 64 bit AMBIENT CONDITIONS Temp. 10 - 40°c Relative humidity 25 to 80 % non condensed MEASURED AND CALCULATED PARAMETERS • RAW (Insp. exp. tot.), SRAW, GAW, SGAW, ... • TGV, VC, IRV, ERV, RV, TLC, ... • Slow Spirometry : VC, ERV, IRV, IC, EC • Foced Spirometry : FEV1, FIV1, FVC, FEV1/FVC, FEV1/VC, • FEV6, PEF, F25, F50,F75, MEF, MVV, ... • Bronchodilation and challenge test, dose-response curves, reactivity threshold, ... • V Comp., P. Alv. (option) • TLCO : AV, TLCO / AV, TLCO - NO : Dm, Vc; TLCO ss (option) • Compliance stat./dyn., RL stat./dyn., CL stat./dyn., EL dyn., W vis. (option) • MIP/Mep,SNIP, ... (option) • NEP, RNep , Exp. Flow Lim, ... (option) • FRC N 2 - RV N 2 - TLC N 2 (NEW) • Closing Volume • Lost Volume, Intrathoracic Pressure & Partial FLow/Volume curve OPTIONS • Mixed (Volumetric and Barometric bodyplethysmograph) • TLCO He, TLCO NO, TLCO CH 4 , TLCO steady state /TLCO rebreathing • MIP/MEP, SNIP, NEP, Rint • Static and dynamic Compliance • Integrated automatic nebulizer, PROVO 4. • External compensation Box • Computer integration trolley with electrical isolation transformer • Double Door for wheelchair access • Medisoft network • Data transfer & reception (HL7,…) • Automatic data backup • Disabled handrail support • Colour Lazer Printer Your official dealer : BELGIUM HEADQUARTER P.A.E. de Sorinnes Route de la Voie Cuivrée 1 B-5503 Sorinnes – Belgium Tel: +32 (0)82 22 30 20 Fax: +32 (0)82 22 33 34 [email protected] www.medisoft.be MEDISOFT FRANCE Rue du Maréchal de Lattre de Tassigny, 8 59000 Lille Tel: + 33 (0)825 280 030 Fax: +33 (0)320 787 609 [email protected] www.medisoft.fr MEDISOFT CHINA West Tower, Shun Tak Centre 168 Connaught Road Central Hong Kong Tel: +852 2267 8933 Fax: +852 2267 8983 [email protected] MEDISOFT ITALIA Via Germania, 14 35127 CAMIN (PD) ITALY Tel: +39 049 87 03 355 Fax: +39 049 87 03 388 [email protected] www.medisoft-ram.it Medisoft s.a. reserves the right to change and improve the above specifications without prior notice MEDISOFT GERMANY GmbH Universitätsstraße, 136 D-44799 Bochum GERMANY Tel.: +49 (0) 234 976-58410 Fax: +49 (0) 234 976-69507 [email protected] www.medisoft-pft.de 120515_Bodybox_EN (Volumetric option) p The reference instrument of a PFT laboratory p An unrivaled customisation (The largest selection of optional measures) p Environment comfortable for the patient p High tec and high quality design p Fast and accurate measurements p Low running cost & easy of maintenance p Intuitive Software Lost Volume, IntraTh. Pressure & Partial Flow/Volume curve analysis (See specific brochure) NEW For more details, visit our Website Bodybox (with handrail support option) The most Intuitive, userfriendly and complete sofware basic version • A sophisticated and powerful data-base function and electronic storage • Trends Report (Historic function) • Interpretation function • Comment function • Off Line input and on line data transfer • Report designer • Predicted value editor • Choice of languages • Choice of units for the measured parameters • Bronchial test generation • Blood gases with blood chemistry analysis from manual entry • Users Units capability • Measurement sequencing configuration • Full calculation function : display of calculation points with manual correction capability • Technical toolbox to enable diagnostic function and full program control • Inbuilt quality control with calibration markers for performance • Teleassistance or VPN assist
Transcript
  • 0029

    Cert. N°: 09/BE/1814ISO 13485 (2003)

    BODYBOX 5500®Barometric total bodyplethysmograph

    EXPAIR software

    The MediSoft factory is a state of the art modern facility with clinical research, precision engineering and computer design departments.

    GEnERAl SPEcIfIcAtIonS

    Dim. Standard Double Door/XL Paediatric (HxWxD)cm 176x87x71 179x120x83 140x66x55 Weight ±130kg ±150Kg ±105Kg Internal Volume 960L ±1250L ±450L Patient chair Pneumaticadjustement BodyBox closing door Sturdyclosingandinternalhandle Power requirements 230/115VAC50/60Hz Power Consumption 100VA(module) Warm up Time 20min(minimum)Conformtoelectricalsafetyreq.IEC60601/1andCE0029

    BODYBOX 5500 PAtIEnt VAlVE

    Pneumotachograph Lillycone Range 0,03to15L/secor20L/sec Résistance 0,4cmH2O/L/sec Relativeaccuracy Error<3%Volumeconv.toBTPSintegratedthermometer(optionalbarometer)Automaticzeroshiftcorrectionofmeasuringelements

    Softwarecomputerisedlinearization Patient valve Pneumatic(TimeO/C:30mS) DeadSpace <60ml/30ml(paediatric).DisinfectionSimpleDismantlingforcoldcleaning Valve Support Arm Moveablearmwith3joints

    PRESSuRE tRAnSducERS

    Piezoresistivesensorsprotectedfromoverload Sensitivity Resolution Calibration Boxpres ±0,5cmH2O BoxPres 0,05cmH2O BoxPres Integrated30mlpump Mouthpres ±50,0cmH2O MouthPres.&Flow 0,01cmH2O MouthPres. Watercolumn Pres.MIP/MEPSNIP ±280,0cmH2O Linearity Error<0,1% Pneumotachograph semi.auto.with1to3L Mouthflow ±5,0cmH2O RelativeAccuracy Error<0,01%syringewithERS/ATSqualitycontrolindicator

    GAS AnAlyzERS

    Helium Thermalconductivity Range 0to15%He Relativeaccuracy ±0,1% Responsetime ±200msecFastHe ±10secHeSTD Carbon monoxide infrared/FastorFuelCell Range 0to0,350%CO Relativeaccuracy ±0,1% Responsetime ±150msecFastCO ±20secCOFuelCell O2 ChemicalFuelCell Range 0to100%O2 Relativeaccuracy ±0,02% Responsetime ±150msec CO2 infrared Range 0to10%CO2 Relativeaccuracy ±0,01% Responsetime ±120msec

    oPtIonAl GAS AnAlyzERS

    Multigas analyser Infraredspectrometer(CO,CH4,CO2,C2H2) Range 0to0,350%,CO2:0-10% Relativeaccuracy ±0,1% Responsetime <20sec(10-90%FS) Nitric oxide Chemicalfuelcell Range 0-450ppm Relativeaccuracy ±0,1% Responsetime <10sec(10-90%Fs)

    GAS SuPPly SPEcIfIcAtIonS

    BodyBox Compressedair TLCOHeoption 0,3%CO,14%He,21%O2,remN2 TLNOoption ±450ppmNo,remN2 TLCOCH4option 0,3%CO,0,3%CH4,21%O2,remN2 Pressureregulator 0-8Bars/15m3/h TLCOss 0,08CO,21%O2remN2 FRCN2 100%O2

    AnAlySER cIRcuIt

    Automatic,rapidandaccuratecalibrationwithqualitycontrol

    VolumEtRIc BodyBoX (oPtIon)

    Pneumotachograph doubleGridLillycone Range 0,01to15L/sec Resistance 0,1cmH2O/L/sec Relativeaccuracy Error<3%

    comPutER IntERfAcE

    Type SerialRS232orUSBConversion 12&16bit. Acq.frequency 100Hz/chanels(Multigas3500Hz) Transmissionspeed 115,200baud Isolation Systemfullyisolated byoptocoupling Computer PCIntel,19’’monitor, PrinterA4colourDeskjet Operatingsystem Windows7®32or64bit

    AmBIEnt condItIonS

    Temp.10-40°c Relativehumidity25to80% noncondensed

    mEASuREd And cAlculAtEd PARAmEtERS

    •RAW(Insp.exp.tot.),SRAW,GAW,SGAW,...•TGV,VC,IRV,ERV,RV,TLC,...•SlowSpirometry:VC,ERV,IRV,IC,EC•FocedSpirometry:FEV1,FIV1,FVC,FEV1/FVC,FEV1/VC,•FEV6,PEF,F25,F50,F75,MEF,MVV,...•Bronchodilationandchallengetest,dose-responsecurves,

    reactivitythreshold,...•VComp.,P.Alv.(option)•TLCO:AV,TLCO/AV,TLCO-NO:Dm,Vc;TLCOss(option)•Compliancestat./dyn.,RLstat./dyn.,CLstat./dyn.,ELdyn.,Wvis.

    (option)•MIP/Mep,SNIP,...(option)•NEP,RNep,Exp.FlowLim,...(option)•FRCN2-RVN2-TLCN2(NEW)•ClosingVolume•LostVolume,IntrathoracicPressure&

    PartialFLow/Volumecurve

    oPtIonS

    •Mixed(VolumetricandBarometricbodyplethysmograph)•TLCOHe,TLCONO,TLCOCH4,TLCOsteadystate/TLCOrebreathing•MIP/MEP,SNIP,NEP,Rint•StaticanddynamicCompliance•Integratedautomaticnebulizer,PROVO4.•ExternalcompensationBox•Computerintegrationtrolleywithelectricalisolationtransformer•DoubleDoorforwheelchairaccess•Medisoftnetwork•Datatransfer&reception(HL7,…)•Automaticdatabackup•Disabledhandrailsupport•ColourLazerPrinter

    Yourofficialdealer:

    BELGIUM HEADQUARTERP.A.E. de SorinnesRoute de la Voie cuivrée 1B-5503 Sorinnes – Belgiumtel: +32 (0)82 22 30 20fax: +32 (0)82 22 33 [email protected]

    MEDISOFT FRANCERue du maréchal delattre de tassigny, 859000 lilletel: + 33 (0)825 280 030fax: +33 (0)320 787 [email protected]

    MEDISOFT CHINAWest tower, Shun tak centre168 connaught Road centralHong Kongtel: +852 2267 8933fax: +852 2267 [email protected]

    MEDISOFT ITALIAVia Germania, 1435127 cAmIn (Pd)ItAlytel: +39 049 87 03 355fax: +39 049 87 03 [email protected]

    Medisofts.a.reservestherighttochangeandimprovetheabovespecificationswithoutpriornotice

    MEDISOFT GERMANY GmbHuniversitätsstraße, 136d-44799 BochumGERmAny tel.: +49 (0) 234 976-58410 fax: +49 (0) 234 [email protected] 12

    0515

    _Bod

    ybox

    _EN

    (Volumetric option)

    p The reference instrument of a PFT laboratory

    p An unrivaled customisation(The largest selection of optional measures)

    p Environment comfortable for the patient

    p High tec and high quality design

    p Fast and accurate measurements

    p Low running cost & easy of maintenance

    p Intuitive Software

    Lost Volume, IntraTh. Pressure&

    Partial Flow/Volume curve analysis(See specific brochure)

    NEW

    for more details, visit our Website

    Bodybox (with handrail support option)

    The most Intuitive, userfriendly and complete sofware basic version

    •Asophisticatedandpowerfuldata-basefunctionandelectronicstorage

    •TrendsReport(Historicfunction)•Interpretationfunction•Commentfunction•OffLineinputandonlinedatatransfer•Reportdesigner•Predictedvalueeditor•Choiceoflanguages

    •Choiceofunitsforthemeasuredparameters•Bronchialtestgeneration•Bloodgaseswithbloodchemistryanalysis

    frommanualentry•UsersUnitscapability•Measurementsequencingconfiguration•Fullcalculationfunction:displayof

    calculationpointswithmanualcorrectioncapability

    •Technicaltoolboxtoenablediagnosticfunctionandfullprogramcontrol

    •Inbuiltqualitycontrolwithcalibrationmarkersforperformance

    •TeleassistanceorVPNassist

  • FRC N2

    LOST VOLUME

    D800

    AIRWAYS RESISTANCE and CONDUCTANCE (RAW & GAW)

    Theairwaysresistancecanbemeasuredeasilyandquickly.ThesubjectestablishesarestingFRCleveloftidalbreathingandtheoperatorcanthenselecttocollectflowagainstboxdataforanalysis.Thetestcanbeperformedatbothrestingventilationandwiththepantingmethod.Thecorrelationbetweenmethodsisexcellent.Whentheoperatorissatisfiedwiththequalityofthecaptureddatatheocclusionvalvecanbeoperatedtosettheactualthoracicgasvolumeatwhichthemeasurementsaremade.ThisisessentialforameaningfulmeasurementofSgaw.Thesoftwarecontrolallowsmanualfittingoftheslopetothedata,selectionandde-selectionofeffortsforthemean,manualselectionofTidalvolumeandVitalcapacityminimumandmaximumpointsaswellasadjustmentoftheFRClevel.

    THORACIC GAS VOLUME, TOTAL LUNG CAPACITY AND LUNG SUB-DIVISIONS

    ThetestcallsforthesubjecttoachieveastableFRClevel,theoperatorcanthenselectocclusionmode.Thepowerfulsoftwarethenclosesthevalveatanendtidalpointandtheresultingtangentofthemouthpressureversustheboxpressureisthethoracicgasvolume(TGV,FRC).AssubjectschangetheirFRClevelduringtheeffort,thesoftwaremonitorsthebaselineshiftandthenaddsorsubtractsthevolumedifferencefromthemeasuredthoracicgasvolumetoshowthe‘TrueFRC’astheTGV.Afullvitalcapacityeffortthenprovidesthecalculationsofthelungsub-divisionsrelatingtotheTGVmeasurement.Completecontroloverreportedparametersandinformation.Selectionofdata,movementofthetidalvolume,vitalcapacityandFRClevelsaswellasdeletionofpoorefforts.Fivesetsofmeasurementscanberecordedatthesameordifferenttimestoidentifyimprovementsinpatientmeasurements.Threedifferentocclusionmodescanbeselected:1.Insp.cycle-2.Completecycle-3.Multiplecycles

    FRC MULTIBREATH N2 WASHOUT (OPTION)

    IntegratedorwithHypAirArtsMeasurementofTLCbyNitrogenwashout.TheNitrogenwashoutusestheaccumulatedvolumeofoxygentowashnitrogenfromthelungsasthe‘true’FRCvalue.Onscreenvisualisationguidestheuserthroughthefulltestprocedure,makingtheunderstandingandqualitycontrolofthetestakeyfeature.ImportingaVCfromaseparateeffortispossiblewhenthesubjectmaybeunabletoperformthebesteffortwithinthetest.ThemeasuringcircuitusesO2andCO2analysersbysubtractiontomeasurethenitrogen;thepatientcircuitconsistsofanautomatictwo-channelvalvewithautomaticdeliveryof100%O2withalowresistancedemandvalve.TheclosingvolumeiscalculatedfromN2slopeduringamaximalexpiration

    SLOW AND FORCED SPIROMETRY (TOTAL OR PARTIAL)

    TheBodyBox5500allowsfullmeasurementofspirometrywithfacilitiesformultiplelevelspirometryaswellasbronchialchallengetesting.Additionally,incentivespirometryassiststhemeasurementsofchildren.Postvisualizationandposttreatmentprovideaconvenienceofuseparticularlyappreciated:Choiceofgraphicalrepresentation,selectionofcalculationpoints,alignementofflowcurvesonRV,timeevolutionofmeasuredparametersbynumericalandgraphicalrepresentation,deletionofpooreffort,trendgraphinganddoseresponsecurves.

    MEASUREMENT OF DIFFUSION CAPACITY TLCO (OPTION)

    UNIQUE - the only body plethysmograph offering the range of 5 diffusion methods.

    Single Breath using the helium trace gas He

    ThewellknowntechniquedescribedbyJ.E.CotesbasedontheJonesMeademethod.Usingabagcollectionsystemthesubjectcanbecontrolledforinspiratoryvolume,washout(discard)volumeandSamplevolume.Thismethodhasprovenrepeatabilityandthemethodwasthesameasthatusedtocollectthepredictedvaluesweusetoday.

    TLCO-NO (trace gas He) NEW & EXCLUSIVE

    Membranediffusionandcapillarybloodvolume(Dm&Qc)measurement.Regardedasthe‘True’diffusioncharacteristicandthemostusefulindicatorofmembranethickening,thismeasurementtakesonanewleaseoflife.ThepowerfulExp’Airsoftwaremakesthecalculationspainless,thecombinationofNOandCOfollowstheworkofProf.GuenardofBordeaux.Simpletoperformandrapidresultsaddthistest

    tothelistoffavouritestudiesundertakeninroutinepractice.AdditionallythismeasurementcanbeperformedinconjunctionwithNEP,thisthenallowstheevaluationofpulmonarybloodflowanditsabilitytorecruitfromthecapillaryreserve.

    Single Breath & Intra Breath using Methane trace gas (CH4)

    Usingfastgasanalysis,thismethodcollectstheexhaledbreathdirectlyasahighresolutiondataarray.Thishastheadvantagethatposttestanalysiscanbeperformedaligningthestartofsampleontothealveolarplateauaftertheclearancesofallthedeadspaces.Asampleaslowas50mlcanbeusedtocalculatethediffusion.Thiscanovercomethevolumelimitationofothersystemsandmethods.

    Single Breath & Intra Breath using trace gas (He)

    Themostsignificantimprovementtodiffusionmeasurementsisthelast10years.PreviouslyonlypossiblewithamassspectrometerandrapidIRcarbonmonoxideanalyzer.ThenewMedisoftrapidgasanalyzertechnologyallowsthemeasurementsin‘realtime’ofexhaleddiffusiongases.Thisisbothintraditionalsingebreathandintrabreathmodes.Withtypicalresponsesintherangeof100-200msfortwodiscreteanalyzersthesystemisperfectlymatched.AsthismethodisfaithfultothestandardbywhichthePredictedValueswerecollected,thedatayieldsthemostreproducibledataforsubjectsrelatedtonormaldata.Themethodextendseasilyto‘steadystate’diffusionin‘realtime’andsohasnovolumelimitationforthemeasurementsofdiffusion.ThepropertiesofHeliumasthetracesgasisbetterpresentedforgasmixingthanalternative,leadingtomoveaccurateestimatesoftotalsurfacearearepresentedbysinglebreathtotallungCapacity(TLC)thealveolarVolume(Va)

    Intra Breath diffusion He & CH4

    Thesampleistakenduringaslowandconstantexhalationintherangeof200–500ml/sec.Applyinglinearregressionstothedataarrayoftheexpiratorygas,thealveolarconcentrationsarecalculated.Asthismethodrequiresnobreathholding,itwillgreatlybenefitsomesubjectgroups.

    Steady State diffusion Tlco ss EXCLUSIVE

    Medi-softhastakenanewlookatthismethod,usingfastgastechnologyandreplacingtheolderbulkyinstrumentation.Thisisa“NEW”methodforanewageofdiffusionmeasurement.Requiringminimalsubjecteffort,thismethodisespeciallyhelpfulforobtainingmeasurementswithchildrenandreluctantsubjects.Performedatasteadystatebreathingcondition,themeasurementisvalidassoonasthesubjectsventilationisuniformandstabilized.

    NEP (OPTION) EXCLUSIVE

    Anewandverysensitivetestthatisspecificandreproduciblefordeterminingthedegreeofexpiratoryflowlimitationbothatrestandduringexercise,particularlywithsubject’sknowntohaveobstructivelungdisease.Thetestappliesanegativepressuretothemouthpieceduringtheexpiratoryphase,thisallowsthecomparisonoftheflowvolumeloopwiththetidaleffortswhenreviewedasaflowvolumeloopdisplay.Thismethodalsoallowstheindirectmeasuremtoftheresistance(RNep)whichprovidesagoodalternativetothestandardscreeningmethod.

    VENTILATION MECHANICS (OPTION)

    •MIP–MEP:MaximalInspiratoryandExpiratoryPressuresasanassessmentofrespiratorymusclestrength,alsousefulforweaningsubjectsfromventilators,…•SNIP:measurementofthemaximalnasalinspiratorypressureusinganasalcanular.Anon-invasiveestimateofmusclefatigue.•STATICANDDYNAMICCOMPLIANCEANDRESISTANCE:Theuseofanoesophagealballooncatheterinsertedintothesubjectallowsthemeasurementsofbothstaticanddynamiccompliance.Thecomponentsofcomplianceandresistancearefundamentaltothemechanicsofthelung

    PROVO 4 (OPTION)

    Equipmentforfullyautomatedbronchochallengetestwithautomaticnebulizer.Thisoptionprovidesfullcontrolofproductsanddosesusedandoftestperformingcriteriaforbronchochallengetesting

    LOST VOLUME (OPTION)

    seespecificbrochure

    INTRATHORACIC PRESSURE (OPTION)

    seespecificbrochure

    p The perfect unit for :p Pulmonary Function Test with both

    children and adultsp Ventilation mechanicsp Bronchodilatation studiesp Hypersensitivity research

    (challenge tests)

    BODYBOX 5500

    New trolley «Standard V2» (With Wide Screen 24" option)

    Customized Bodybox: – Metallic gray – Acrylic seat

    from basic to advanced version, medisoft is the only manufacturer able to offer you customisation at a standard price!

    p Ergonomically adjustable to your needs :p Bring assistance to disabled or infirm subjects with

    the handrail support and the Double door version.p No stress : pleasant environment for the patient.p Add an interactive dimension and improve the quality of

    your tests by choosing the incentive screen.p Customise your box by choosing the size*,

    the color and type of seat you want.

    *(Standard, XL, Double door, Paediatric or Customised)