JHU
Experiments on Braced Thin-Walled Cold-Formed Steel C and Z Beams in Flexure
Ben SchaferAsst. Professor
The Johns Hopkins UniversityJune 2001
JHU
acknowledgments
• Sponsors– AISI and MBMA– CECO Buildings, VP Buildings, Clark Steel
• People– Cheng Yu - graduate RA– Sam Phillips - undergraduate RA– Liakos Ariston - undergraduate RA– Jack Spangler - technician– Chuck Pearson - Prosser Steel
JHU
overview
• Background• Objective• Setup• Typical results• Influence of details• Preliminary results• Continuing work
JHU
background / motivation
• Effective width of a web of a cold-formed steel beam?• Unification of design? North American Specification• American (AISI) vs. Canadian (S136) method• AISI expressions inconsistent and discontinuous• AISI predicted strength > S136 predicted strength• Industry skeptical of academic test data showing
problems with AISI predicted strength• Definitive testing needed
JHU
local buckling with web/flange interaction
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
1 2 3 4 5 6 7 8 9 10
ratio of web height to flange width (h/b)
plat
e bu
cklin
g co
effic
ient
for t
he fl
ange
kf
ξ = 3ξ = 2ξ = 1.4ξ = 1
local bucklingfinite strip analysis
ξ = 3
ξ = 2, pure bending
ξ = 1.4
ξ = 1
JHU
objective
• New tests are needed to provide direction for the Specification and definitively determine the role of local web/flange interaction for the web effective width
• Requirements– Simple repeatable tests on industry ‘C’s and ‘Z’s– Account for issues in practice related to local buckling of
these members, such as attachment to sheeting– Focus on local buckling limit states
leave distortional and lateral buckling issues for later
JHU
testing matrix
• Dimensions: h, b, d, t.• Isolation of h/t variation sought• MBMA ‘Z’s (purlins): h,b,d, fixed, t varied• SSMA ‘C’s (studs, joists): b,d fixed, h and t varied
h/t h/b b/t d/t d/bTests to be performed num min max min max min max min max min maxbracing configuration 3Z: h,b,~d fixed, t varied 7 71 144 3.4 same 21 42 8 13 0.28 0.41Z: h,b,~d fixed, t varied 5 96 158 3.3 same 29 48 8 13 0.26 0.29C: h,b,d fixed, t varied 5 82 242 4.0 same 21 61 6 19 0.31 sameC: b,d,t fixed, h varied 5 67 222 1.8 6.0 37 same 12 same 0.31 samemiscellaneous 4
TOTAL 29 67 242 1.8 6.0 21 61 6 19 0.26 0.41
JHU
members
JHU
testing setup
spreader beam to apply the load at 1/3 points
tubes at ends and at support pointsbolting the two specimens together,top of tube flush with top of purlin toavoid crippling at loading point.
4x4x1/4 angles bolted to endplates and specimens to avoidcrippling at ends.
1 1/4 x 1 1/4 x 0.057 anglesconnecting tension flanges of 2specimens to insure they act asa unit 12” on center
standard decking fastened through flanges ofpurlins to retard lateral and distortional buckling. fastener patterns and spacing investigated.
each span is 5’ 4” on center. Length is selectedconsidering: shear demands, actuator capacity,actuator stroke, and future testing (dist.
buckling when panel is removed)
JHU
overall view
JHU
typical failure mechanism
JHU
typical online results
JHU
elastic buckling modes
local distortional
½λ ~ 5 in. ½λ ~ 20 in.
JHU
elastic buckling
0.50
0.90
1.30
1.70
70.0 90.0 110.0 130.0
web slenderness (h/t)
M/M
y
Local ElasticDistortional Elastic
h=8.5 in.b=2.5 in.d=0.8 to 1.0 in.t=0.059 in. to 0.120 in.fy=60 ksi
JHU
continuous spring analysis (finite strip)
JHU
fe (elastic) model to develop detail
JHUdistortional predicted as lowest eigenmode
(single screw pattern, t=0.073 in.)
panels removed forvisual purposes only
JHU
influence of details
JHUlocal predicted as lowest eigenmode
(paired screw pattern, t=0.073 in.)
panels removed forvisual purposes only
JHU
influence of detailsSpecimen Mtest/My Mtest/Maisi note
8.5Z073-5E6W 0.78 0.86 single panel-to-purlin screws - 12" o.c.
8.5Z073-1E2W 0.80 0.88 single panel-to-purlin screws
on both sides of raised corrugation8.5Z073-4E3W 0.86 0.96 paired panel-to-purlin screws
on both sides of raised corrugation
8.5Z073-5E6W 8.5Z073-4E3W
JHU
prediction of 8.5 in. ‘Z’s
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
70.00 90.00 110.00 130.00 150.00web slenderness (h/t)
M/M
y
AISI (1996)direct strength: distortional
direct strength: local
JHU
prediction of 8.5 in. ‘Z’s
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
70.00 90.00 110.00 130.00 150.00web slenderness (h/t)
M/M
y
AISI (1996)direct strength: distortional
direct strength: local
inelastic reserve capacity My<M<Mp
fastener pattern / spacing influence
specimens damaged before testing
JHU
comments
• web/flange interaction• details• ongoing work
– testing on ‘C’s– improved monitoring of testing– numerical modeling and extension of results– refining design methodology
• future– remove panels, allow distortional buckling– move away from effective width?
JHU
detailed testing planout-to-out-dimensi inner nondimensional ratios studied
h b d r θ t E fy h/t h/b b/t d/t d/b(in.) (in.) (in.) (in.) (deg) (in.) (ksi) (ksi)8.5 2.5 0.71 0.313 50 0.059 29500 60 144.1 3.4 42.4 12.0 0.288.5 2.5 0.78 0.313 50 0.065 29500 60 130.8 3.4 38.5 12.0 0.318.5 2.5 0.92 0.313 50 0.073 29500 60 116.4 3.4 34.2 12.6 0.378.5 2.5 0.94 0.313 50 0.082 29500 60 103.7 3.4 30.5 11.4 0.388.5 2.5 0.96 0.313 50 0.092 29500 60 92.4 3.4 27.2 10.4 0.388.5 2.5 0.98 0.313 50 0.105 29500 60 81.0 3.4 23.8 9.4 0.398.5 2.5 1.01 0.313 50 0.120 29500 60 70.8 3.4 20.8 8.4 0.4111.5 3.5 0.92 0.313 50 0.073 29500 60 157.5 3.3 47.9 12.6 0.2611.5 3.5 0.94 0.313 50 0.082 29500 60 140.2 3.3 42.7 11.4 0.2711.5 3.5 0.96 0.313 50 0.092 29500 60 125.0 3.3 38.0 10.4 0.2711.5 3.5 0.98 0.313 50 0.105 29500 60 109.5 3.3 33.3 9.4 0.2811.5 3.5 1.01 0.313 50 0.120 29500 60 95.8 3.3 29.2 8.4 0.29
8 2 0.63 0.076 90 0.033 29500 60 242.4 4.0 60.6 18.9 0.318 2 0.63 0.045 90 0.043 29500 60 186.0 4.0 46.5 14.5 0.318 2 0.63 0.085 90 0.054 29500 60 148.1 4.0 37.0 11.6 0.318 2 0.63 0.107 90 0.068 29500 60 117.6 4.0 29.4 9.2 0.318 2 0.63 0.153 90 0.097 29500 60 82.5 4.0 20.6 6.4 0.31
12 2 0.63 0.085 90 0.054 29500 60 222.2 6.0 37.0 11.6 0.3110 2 0.63 0.085 90 0.054 29500 60 185.2 5.0 37.0 11.6 0.318 2 0.63 0.085 90 0.054 29500 60 148.1 4.0 37.0 11.6 0.316 2 0.63 0.085 90 0.054 29500 60 111.1 3.0 37.0 11.6 0.314 2 0.63 0.085 90 0.054 29500 60 74.1 2.0 37.0 11.6 0.31
3.62 2 0.63 0.085 90 0.054 29500 60 67.0 1.8 37.0 11.6 0.31
AISI and S136differentZ
C
JHU
typical results
JHU
influence of detailsSpecimen Mtest/My Mtest/Maisi note
8.5Z059-1E2W 0.81 0.95 paired panel-to-purlin screws
on both sides of raised corrugation and in pan8.5Z059-4E3W 0.83 0.99 paired panel-to-purlin screws
on both sides of raised corrugation
8.5Z059-1E2W 8.5Z059-4E3W
JHU
h/t b/t d/t h/b d/b min max min max min max min max min maxMBMA Z’s 53 170 17 47 5 17 3.1 3.7 0.28 0.45SSMA members 25 318 11 132 1 33 1.0 10.9 0.12 0.33Rack members 23 136 16 45 6 15 1.0 3.2 0.27 0.38Elhouar and Murray (1985) 68 165 24 52 3 24 2.6 3.8 0.09 0.49Schafer and Peköz (1999) 43 270 15 75 3 34 1.5 13.7 0.14 0.70
industry vs. academia?
h/b=1.0 3.3 10.0
available membersexperimental data