ILC - Tube Fans Cased Fans CASED 48 Telephone: 01206 222 555 Fax: 01206 222 905 Email: [email protected] Express Website: www.flaktwoods.com/express Fan Selector: www.flaktwoods.com/fanselector Sizes ILC/1P – 100mm, ILC/2P – 125mm, ILC/3P – 150mm, ILC/4P – 200mm, ILC/5P – 250mm. ILCM/1 – 100mm, ILCM/2 – 125mm, ILCM/3 – 150mm, ILCM/4 – 200mm, ILCM/5 – 250mm, ILCM/6 – 315mm. Fan Performance All the advantages of axial flow fans combined with the benefits of r adial fan pressure characteristics. Built in guide vanes are moulded in to plastic casings . Impellers ILC/1P-ILC/5P are manufactured from plastic mater ials incorporating metal back plates. ILCM/1-ILCM/6 are of all metal constr uction. Motors All sizes utilise an external-rotor motor and an inter nally mounted capacitor. All motors are supplied with sealed for life bearings and overheat protection. All fans are speed controllable with Fläkt Woods speed controllers. Electrical Supply 220 - 240V / 50Hz / 1 φ Temperature Range ILC/1P, ILC/2P both to 70˚C, ILC/3P to 75˚C & ILC/4P & ILC/5P to 50˚C ILC/1M , ILC/2M, ILC/3M all to 80°C , ILC/4M to 70˚C & ILC/5M & ILC/6M to 60˚C . Casings All plastic casings are man ufactured from robust shock resistant, fire retardant polyamide glass-fibre impregnated mater ial providing durable and lightweight construction. The fan casing offers circular inlet and outlet connections with a b uilt in ter minal box. All Metal casings are manufactured from pre-galvanised steel and powder coated in RAL 7035 light grey. All fans to IP44 as standard. Accessories Non-return damper, duct mounting clamps, silencers, electronic speed controllers, flexible connectors, electric heater batteries and panel filter cassettes . Application Guide 100mm – 315mm diameter inlet/outlet Speed control on all f ans Volume flow up to 0.44m 3 /s Multi-functional Total pressure up to 700 Pa Low noise levels Durable light weight construction 2 year guarantee Easy to install
Transcript

ILC - Tube FansCased Fans

CASED 48Telephone:

01206 222 555Fax:

01206 222 905Email:

[email protected] Website:

www.flaktwoods.com/expressFan Selector:

www.flaktwoods.com/fanselector

Sizes

ILC/1P – 100mm, ILC/2P – 125mm, ILC/3P – 150mm, ILC/4P – 200mm, ILC/5P – 250mm.

ILCM/1 – 100mm, ILCM/2 – 125mm, ILCM/3 – 150mm, ILCM/4 – 200mm, ILCM/5 – 250mm,

ILCM/6 – 315mm.

Fan Performance

All the advantages of axial flow fans combined with the benefits of r adial fan pressure

characteristics. Built in guide vanes are moulded in to plastic casings .

Impellers

ILC/1P-ILC/5P are manufactured from plastic mater ials incorporating metal back plates.

ILCM/1-ILCM/6 are of all metal constr uction.

Motors

All sizes utilise an external-rotor motor and an internally mounted capacitor. All motors are

supplied with sealed for life bearings and overheat protection. All fans are speed controllable

with Fläkt Woods speed controllers.

Electrical Supply

220 - 240V / 50Hz / 1 φ

Temperature Range

ILC/1P, ILC/2P both to 70˚C, ILC/3P to 75˚C & ILC/4P & ILC/5P to 50˚C

ILC/1M , ILC/2M, ILC/3M all to 80°C , ILC/4M to 70˚C & ILC/5M & ILC/6M to 60˚C .

Casings

All plastic casings are manufactured from robust shock resistant, fire

retardant polyamide glass-fibre impregnated mater ial providing

durable and lightweight construction. The fan casing offers circular

inlet and outlet connections with a b uilt in terminal box. All Metal

casings are manufactured from pre-galvanised steel and powder

coated in RAL 7035 light g rey. All fans to IP44 as standard.

Accessories

Non-return damper, duct mounting clamps, silencers,

electronic speed controllers, flexible connectors, electric

heater batteries and panel filter cassettes.

Application Guide

• 100mm – 315mm diameter inlet/outlet

• Speed control on all fans

• Volume flow up to 0.44m3/s

• Multi-functional

• Total pressure up to 700 Pa

• Low noise levels

• Durable light weight construction

• 2 year guarantee

• Easy to install

Express Range Cased Range.qxd 18/6/09 09:25 Page 48

*For wiring diagram reference see page 53 code CDWILCG.

Performance & Electrical Data

ProductCode

Speed(rev/min)

220-240V/50 Hz/1φ m3/s at Pa (Static)

ProductNumber

MotorRating(kW)

Full LoadCurrent

(at 230V)(A)

StartingCurrent

(at 230V)(A)

SpeedController

50 75 100 150 200 300 350 400

Electronic

ILC/1M 2670 DC503105 0.06 0.30 0.45 ME1.1 0.06 0.06 0.05 0.04 0.03

ILC/2M 2610 DC503106 0.06 0.30 0.45 ME1.1 0.08 0.07 0.06 0.05 0.04

ILC/3M 2570 DC503107 0.9 0.41 0.8 ME1.1 0.17 0.15 0.14 0.12 0.1 0.06

ILC/4M 2580 DC503108 0.19 0.9 1.6 ME1.1 0.26 0.23 0.22 0.2 0.15 0.11 0.06

ILC/5M 2510 DC503109 0.19 0.9 1.6 ME1.1 0.31 0.3 0.27 0.25 0.22 0.17 0.11

ILC/6M 2260 DC503110 0.29 1.3 2.0 ME1.3 0.44 0.43 0.41 0.38 0.34 0.26 0.19 0.06

Sound Data

ProductCode

Sound Power Levels (dB) SoundPressure

levels @ 3m

In Octave Band Centre Frequency HZ

125 250 500 1K 2K 4K 8K

ILC/1M

Inlet 63 68 60 59 58 51 44 44

Outlet 65 69 59 59 58 51 44 45

Breakout 55 49 37 42 41 35 29 27

ILC/2M

Inlet 61 63 63 62 59 51 43 46

Outlet 62 66 62 60 58 52 45 45

Breakout 51 47 35 40 35 35 27 24

ILC/3M

Inlet 77 79 68 69 61 59 49 53

Outlet 70 71 61 67 62 58 47 50

Breakout 62 58 49 46 44 39 29 33

ILC/4M

Inlet 69 71 69 66 61 61 56 51

Outlet 71 75 67 69 66 63 55 53

Breakout 64 52 51 50 47 46 37 35

ILC/5M

Inlet 69 68 65 63 60 60 56 48

Outlet 69 73 67 68 66 63 57 52

Breakout 62 50 49 50 48 45 37 34

ILC/6M

Inlet 73 68 66 63 60 59 57 48

Outlet 72 72 69 69 67 61 57 53

Breakout 68 54 46 53 53 44 36 38

ILC - Metal Tube FanCased Fans

Bold text denotes Super Express Product, next day delivery available if ordered by 4pm.

Telephone:01206 222 555

Fax: 01206 222 905

Email: [email protected]

Express Website:www.flaktwoods.com/express

Fan Selector:www.flaktwoods.com/fanselector

49CASED

The fan noise levels shown are for the specified operating point. When an electronic controller is incorporated, a magnetic not e (enhanced motor noise) can occur - par ticularly if the fan is operating at speeds well below maximum.For noise sensitive applications FWL recommend using an auto transformer speed controller .

Express Range Cased Range.qxd 18/6/09 09:25 Page 49

ILC - Metal Tube FanCased Fans

Dimensions

ProductCode A B C D E

FanWeight

(kg)

DamperProductNumber

FDamperWeight

(kg)

ILC/1M 100 245 208 168 20 3 DA410605 70 0.2

ILC/2M 125 245 193 153 20 3 DA410606 90 0.3

ILC/3M 150 345 231 191 20 4 DA410607 100 0.4

ILC/4M 200 345 233 193 20 5 DA410608 120 0.7

ILC/5M 250 345 238 198 20 5 DA410609 150 1

ILC/6M 315 405 253 213 20 6.5 DA410610 150 1.2

ProductCode

SilencerProduct

Code

SilencerProductNumber

Octave Band Centre Frequency – Hz - Attenuation Dimensions

63 125 250 500 1K 2K 4K øA øB C Weight(kg)

ILC/1M S100 DH100061 4 8 26 34 41 45 25 100 200 600 4.1

ILC/2M S125 DH125062 3 6 22 28 37 38 22 125 225 600 4.5

ILC/3M S150 DH150062 2 5 19 24 34 32 19 150 250 600 5.5

ILC/4M S200 DH200062 1 4 17 22 29 25 18 200 300 600 7

ILC/5M S250 DH250062 1 6 21 27 39 25 19 250 355 900 12.2

ILC/6M S315 DH315062 0 5 18 23 32 20 18 315 415 900 15

Fixings not supplied. Clamps are available from your Express distributor .

CASED 50Telephone:

01206 222 555Fax:

01206 222 905Email:

[email protected] Website:

www.flaktwoods.com/expressFan Selector:

www.flaktwoods.com/fanselector

All dimensions shown in mm.

50, 52.qxd 18/6/09 10:36 Page 1

ILC - Plastic Tube FanCased Fans

Performance & Electrical Data

ProductCode

Speed(rev/min)

220-240V/50 Hz/1φ m3/s at Pa (Static)

ProductNumber

MotorRating(kW)

Full LoadCurrent

(at 230V)(A)

StartingCurrent

(at 230V)(A)

SpeedController

50 75 100 150 200 300 350 400

Electronic

ILC/1P 2640 DC503100 0.06 0.3 0.45 ME1.1 0.065 0.06 0.05 0.04 0.03

ILC/2P 2600 DC503101 0.065 0.3 0.45 ME1.1 0.08 0.08 0.07 0.05 0.04

ILC/3P 2490 DC503102 0.1 0.5 0.93 ME1.1 0.18 0.17 0.16 0.14 0.12 0.07 0.04

ILC/4P 2570 DC503103 0.19 0.9 1.6 ME1.1 0.26 0.25 0.24 0.21 0.19 0.14 0.12 0.9

ILC/5P 2580 DC503104 0.19 0.9 1.6 ME1.1 0.29 0.28 0.27 0.24 0.22 0.16 0.14 0.11

*For wiring diagram reference see page 53 code CDWILCG.

Sound Data

ProductCode

Sound Power Levels (dB) SoundPressure

levels @ 3m

In Octave Band Centre Frequency HZ

125 250 500 1K 2K 4K 8K

ILC/1P

Inlet 61 71 57 59 56 49 40 45

Outlet 64 72 55 57 53 50 42 44

Breakout 49 48 46 51 43 35 25 32

ILC/2P

Inlet 57 67 59 60 57 50 42 44

Outlet 58 70 57 58 55 50 43 44

Breakout 46 49 46 48 42 34 24 30

ILC/3P

Inlet 66 67 64 64 58 57 49 47

Outlet 66 63 61 63 58 56 48 46

Breakout 56 52 56 52 48 41 32 36

ILC/4P

Inlet 65 71 67 64 63 63 56 50

Outlet 66 74 65 66 65 63 54 51

Breakout 60 63 59 54 49 46 34 40

ILC/5P

Inlet 66 69 68 65 60 59 57 50

Outlet 68 72 67 66 64 60 56 51

Breakout 63 56 54 51 50 43 36 37

Telephone:01206 222 555

Fax: 01206 222 905

Email: [email protected]

Express Website:www.flaktwoods.com/express

Fan Selector:www.flaktwoods.com/fanselector

51CASED

The fan noise levels shown are for the specified operating point. When an electronic controller is incorporated, a magnetic not e (enhanced motor noise) can occur - par ticularly if the fan is operating at speeds well below maximum.For noise sensitive applications FWL recommend using an auto transformer speed controller .

Bold text denotes Super Express Product, next day delivery available if ordered by 4pm.

Express Range Cased Range.qxd 18/6/09 09:25 Page 51

ILC - Plastic Tube FanCased Fans

Dimensions

ProductCode A B C D E

FanWeight

(kg)

DamperProductNumber

FDamperWeight

(kg)

ILC/1P 100 245 220 160 30 2 DA410605 70 0.2

ILC/2P 125 245 220 160 30 2.3 DA410606 90 0.3

ILC/3P 150 340 230 170 30 3.1 DA410607 100 0.4

ILC/4P 200 340 230 170 30 4.1 DA410608 130 0.7

ILC/5P 250 340 230 170 30 4.5 DA410609 150 1

ProductCode

SilencerProduct

Code

SilencerProductNumber

Octave Band Centre Frequency – Hz - Attenuation Dimensions

63 125 250 500 1K 2K 4K øA øB C Weight(kg)

ILC/1P S100 DH100061 4 8 26 34 41 45 25 100 200 600 4.1

ILC/2P S125 DH125062 3 6 22 28 37 38 22 125 225 600 4.5

ILC/3P S150 DH150062 2 5 19 24 34 32 19 150 250 600 5.5

ILC/4P S200 DH200062 1 4 17 22 29 25 18 200 300 600 7

ILC/5P S250 DH250062 1 6 21 27 39 25 19 250 355 900 12.2

Fixings not supplied. Clamps are available from your Express distributor .

CASED 52Telephone:

01206 222 555Fax:

01206 222 905Email:

[email protected] Website:

www.flaktwoods.com/expressFan Selector:

www.flaktwoods.com/fanselector

All dimensions shown in mm.

50, 52.qxd 18/6/09 10:36 Page 2

Wiring Diagram

CDWILCG

Telephone:01206 222 555

Fax: 01206 222 905

Email: [email protected]

Express Website:www.flaktwoods.com/express

Fan Selector:www.flaktwoods.com/fanselector

53CASED

Fan

ILC - Tube FansCased Fans

Express Range Cased Range.qxd 18/6/09 09:25 Page 53


Recommended