13
Technical Information Hydrostatics External Remote Charge Pressure Filter www.danfoss.com
Transcript
Page 1: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Technical Information

HydrostaticsExternal Remote Charge Pressure Filter

www.danfoss.com

Page 2: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Revision history Table of revisions

Date Changed Rev

August 2019 Corrected long filter number 0202

March 2014 Converted to Danfoss layout - DITA CMS 0201

November 2010 Minor update AB

Technical InformationExternal Remote Charge Pressure Filter

2 | © Danfoss | August 2019 11064579 | BC00000064en-000202

Page 3: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

General InformationIntroduction........................................................................................................................................................................................4Features................................................................................................................................................................................................4

System Design ParametersFiltration...............................................................................................................................................................................................5Operating pressure.......................................................................................................................................................................... 7Differential pressure and ß-ratio.................................................................................................................................................7Bypass valve and bypass sensor..................................................................................................................................................7Bypass sensor clearance.............................................................................................................................................................. 10Dimensions.......................................................................................................................................................................................12

Technical InformationExternal Remote Charge Pressure Filter

Contents

© Danfoss | August 2019 11064579 | BC00000064en-000202 | 3

Page 4: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Introduction

For more than 40 years, Danfoss has been developing state-of-the-art components and systems formobile machinery used in off‑highway operations around the world. We have become a preferredsupplier by offering the best of what really matters: The hardware inside your vehicle application.

Features

• Common filter head

• 3 different filter sizes

• Compatible with

‒ H1 P

‒ S 90

‒ S 42

‒ S 40

• Integrated functionality

‒ Bypass valve

‒ Electric contamination indicator

• Servicebility

‒ No extra space for element replacement needed, (side way removal possible)

Technical InformationExternal Remote Charge Pressure Filter

General Information

4 | © Danfoss | August 2019 11064579 | BC00000064en-000202

Page 5: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Filtration

Remote charge pressure filtration

The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor.The pressure differential acting on the filter element also acts on a spring biased bypass spool. This spoolis designed with a magnetic area. When a certain spool position is reached, the magnet closes a switch inthe bypass sensor which allows R2 to be in parallel with R1. This occurs without any mechanical contactbetween the spool and the bypass sensor.

The position of the bypass spool is indicated by the change in the measured sensor

resistance. The change in resistance occurs when R2 is switched in and out of the circuit. When the filter isnot being bypassed, the nominal measured resistance is 510 ohms. When the switch is closed, thenominal measured resistance is 122 ohms.

The bypass spool is designed so the bypass sensor switch will be closed before oil bypasses the filterelement. This gives the machine operator an indication that the filter is very close to bypassing and afilter replacement is required.

For cold start conditions, it is typical that the filter may bypass for a short amount of time while the oil iswarming up. At normal operating oil temperatures, a system that does not yet need a filter replacementwill operate in the non-bypass mode. The addition of an oil temperature sensor and additional controllogic, is recommended to properly determine if a filter replacement is required.

Technical data, pressures

Filter bypass sensor switch closure ∆p 3.7 - 5.1 bar [54 - 74 psi]

Bypass valve ∆p 5.6 ± 0.9 bar [80 ± 13 psi]

T000 159E

Technical data, electric

Max. voltage 48 V

Max. power 0.6 W

Switch open 510 Ω

Switch closed 122 Ω

Resistor tolerance 1 %

Temperature range -20 °C ÷ +100 °C [-4 °F ÷ +212 °C]

IP Rating (IEC 60 529) + DIN 40 050, part 9 with matingconnector

IP 69K

T000 160E

Integral filter head with filter bypass sensors

Bypass spool

Filterbypass sensor

Filterelement

P003 359E

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

© Danfoss | August 2019 11064579 | BC00000064en-000202 | 5

Page 6: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Schematic

P003 195

21M6

outin

R1

R2

Bypass sensor open

Bypass valveclosed

P003 198E

ConnectorDeutsch DTM04-2P

M69/16 -18before filter (upstream)

Pinout

Pin Description

1 Voltage

2 Ground

T000 162E

Alternative pinout

Pin Description

1 Ground

2 Voltage

T000 163E

Pin location

P003 186

1 2

For device electrical schematic, see Schematic, page 5.

H1 Filter bypass sensor mating connector parts list

Description Quantity Ordering number

Mating connector 1 Deutsch DTM06-2S

Secondary wedge lock 1 Deutsch WM-2S

Socket terminal 2 Deutsch 0462-201-20141

Danfoss mating connector kit 1 11031205

T000 164E

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

6 | © Danfoss | August 2019 11064579 | BC00000064en-000202

Page 7: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Operating pressure

Unit

Maximum working pressure bar [psi] 45 [653]

Maximum pressure (cold start) 55 [798]

Differential pressure and ß-ratio

Nominal fl ow at 30 mm2/s and Δp 0.5 bar [7.3 psi] (clean fi lter elementonly)

Min β ratio

Short 60 l/min β7.5 (c) = 75 (β5 (c) ≥ 10)

Medium 80 l/min

Long 105 l/min

Bypass valve and bypass sensor

A common spool is used to activate both the bypass sensor and bypass function leading to the assurancethat the bypass sensor will be closed before the bypass is engaged. The bypass sensor occurs at a filterpressure drop of 4.4 +/-0.7 bar. The minimum pressure drop between bypass sensor and open bypass is1.0 bar.

Bypass sensor

Diffential pressure [bar]

Bypass sensor engages at 4.4 +/- 0.7

T301 041E

Bypass valve function

The bypass valve opens at 1.2 bar +- 0.2 bar above bypass sensor engagement pressure.

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

© Danfoss | August 2019 11064579 | BC00000064en-000202 | 7

Page 8: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

0

2

4

6

8

0 20 40 60 80 100P301 284

Diff

eren

tial p

ress

ure

a cr

oss

filte

r (ba

r)

Bypass valve spool movement

Bypasssensor closed

Bypass valveopens

Pres

sure

dp [b

ar]

1.2 +/-0.2 above bypass sensor "closed"

4.4+/-0.7 nominal

5.1

3.7

P301 285

21M6

outin

R1

R2

Bypass sensor closed

Filter element completly blocked

Bypass valvefully open

P301 303

Bypass valve closedBypass sensor open

Upstream filter

Down-stream filter

P301 304

Bypass valve closedBypass sensor closed

P003 195

21M6

outin

R1

R2

Bypass sensor open

Bypass valveclosed

P301 286

Bypass valve fully openBypass sensor closed

P301 302

21M6

outin

R1

R2

Bypass sensor closed

Bypass valveclosed

Filter Bypass Valve Characteristic (completely blocked Filter element)

Below diagramm shows the differental pressure between filter “in” and “out” with a filter elementcompletely blocked, so that all flow runs across the filter bypass valve.

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

8 | © Danfoss | August 2019 11064579 | BC00000064en-000202

Page 9: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Remote filter 11001484, short, 60 l/min, and 11001485, medium 80 l/min

Bypass valve fully open, blocked filter element

0

2

4

6

8

10

12

0 20 40 60 80 100 120

Flow [lpm]

Dif

fere

ntia

l pre

ssur

e ac

ross

filte

r [ba

r]

(blo

cked

filt

er e

lem

ent m

easu

red

betw

een

M6

and

M3)

P301 305

1000

mm

²/s

450 mm

²/s

130 mm²/s

30 mm²/s

P301 285

21M6

outin

R1

R2

Bypass sensor closed

Filter element completly blocked

Bypass valvefully open

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

© Danfoss | August 2019 11064579 | BC00000064en-000202 | 9

Page 10: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Remote filter 11048860, long, 105 l/min

Bypass valve fully open, blocked filter element

0

2

4

6

8

10

12

0 20 40 60 80 100 120

Flow [lpm]

Dif

fere

ntia

l pre

ssur

e ac

ross

filte

r [ba

r]

(blo

cked

filt

er e

lem

ent m

easu

red

betw

een

M6

and

M3)

P301 306

1000 mm

²/s

450 mm²/s

130 mm²/s

30 mm²/s

P301 285

21M6

outin

R1

R2

Bypass sensor closed

Filter element completly blocked

Bypass valvefully open

Bypass sensor clearance

The bypass sensor is activated by the magnetic bypass valve. For proper function it is required to have nosteel parts around the sensor within in below radius. No steel parts are allowed within a radius of 150 mm[5.91 in]. Moving steel devices or parts are not allowed within a radius of 250 mm [9.84 in].

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

10 | © Danfoss | August 2019 11064579 | BC00000064en-000202

Page 11: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

P003 356E

mm[in]

38[1.50]

150 min[5.91]

250 min[9.84]

37[1

.46]

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

© Danfoss | August 2019 11064579 | BC00000064en-000202 | 11

Page 12: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Dimensions

L

(2x) ∅8.5[0.335] 120

[4.72]

SW 24

P003 233E

96±0,1[3.78±0.004]

25±0

.1[0

.98±

0.00

4]

12±0

.1[0

.47±

0.00

4]

∅95

max

.[3

.74]

168.

6[6

.64]

48.5±0.1[1.91±0.004]

ConnectorDeutsch DTM04-2PPin connection: any order

M6Before filter (upstream)9/16 -18

Filtration Out7/8 -14

Filtration In7/8 -14

Short + Medium Filter assembly

(2x) ∅8.5[0.335]

31.0

±0.1

[1.2

2±0.

004]

8.0±

0.1

[0.3

2±0.

004]

180.

6[7

.11]

132.0[5.20]

116.0±0,1[4.57±0.004]

61.0±0.1[2.40±0.004]

Filtration Out1 1/16 -12

Filtration In1 1/16 -12

Long Filter assembly

mm[in]

L

SW 24

∅95

max

.[3

.74]

Element replacement

Filter assembly In and outport size

L max.mm [inch]

Replacement element

Short 11001484 7/8 -14 205 [8.07] 11004917

Medium 11001485 7/8 -14 233 [9.17] 11004918

Long 11048860 1 1/16 -12 292 [11.49] 11004919

Technical InformationExternal Remote Charge Pressure Filter

System Design Parameters

12 | © Danfoss | August 2019 11064579 | BC00000064en-000202

Page 13: External Remote Pressure Filter Technical Information Manual€¦ · The remote pressure filter head is designed with a filter bypass valve and noncontacting bypass sensor. The pressure

Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic andelectric components. We specialize in providing state-of-the-art technology and solutionsthat excel in the harsh operating conditions of the mobile off-highway market as well as themarine sector. Building on our extensive applications expertise, we work closely with you toensure exceptional performance for a broad range of applications. We help you and othercustomers around the world speed up system development, reduce costs and bring vehiclesand vessels to market faster.

Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobileelectrification.

Go to www.danfoss.com for further product information.

We offer you expert worldwide support for ensuring the best possible solutions foroutstanding performance. And with an extensive network of Global Service Partners, we alsoprovide you with comprehensive global service for all of our components.

Local address:

Danfoss Power Solutions GmbH & Co. OHGKrokamp 35D-24539 Neumünster, GermanyPhone: +49 4321 871 0

Danfoss Power Solutions ApSNordborgvej 81DK-6430 Nordborg, DenmarkPhone: +45 7488 2222

Danfoss Power Solutions (US) Company2800 East 13th StreetAmes, IA 50010, USAPhone: +1 515 239 6000

Danfoss Power Solutions Trading(Shanghai) Co., Ltd.Building #22, No. 1000 Jin Hai RdJin Qiao, Pudong New DistrictShanghai, China 201206Phone: +86 21 3418 5200

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to productsalready on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

© Danfoss | August 2019 11064579 | BC00000064en-000202

Products we offer:

• DCV directional controlvalves

• Electric converters

• Electric machines

• Electric motors

• Hydrostatic motors

• Hydrostatic pumps

• Orbital motors

• PLUS+1® controllers

• PLUS+1® displays

• PLUS+1® joysticks andpedals

• PLUS+1® operatorinterfaces

• PLUS+1® sensors

• PLUS+1® software

• PLUS+1® software services,support and training

• Position controls andsensors

• PVG proportional valves

• Steering components andsystems

• Telematics

Hydro-Gearwww.hydro-gear.com

Daikin-Sauer-Danfosswww.daikin-sauer-danfoss.com


Recommended