+ All Categories
Home > Documents > EY-RC 301, 302: Room controller, ecos301, 302 · EY-RC 301, 302: Room controller, ecos301, 302 ......

EY-RC 301, 302: Room controller, ecos301, 302 · EY-RC 301, 302: Room controller, ecos301, 302 ......

Date post: 10-May-2018
Category:
Upload: vanthien
View: 221 times
Download: 1 times
Share this document with a friend
4
EY-RC 301, 302: Room controller, ecos301, 302 How energy efficiency is improved The ecos 3 controller enables precise room climate regulation and thus ensures minimum energy consumption in the room. Features Part of the SAUTER EY-modulo 3 system family (BACnet MS/TP) Single-room controller for an energy-optimised room climate BACnet room controller (B-ASC) for fan coil unit, chilled beam, chilled ceiling, radiator heater etc. Individual adjustment of the room climate with the ecoUnit382 room operating unit (EY-RU 382) Universal PI and/or binary controller sequence for all the analogue and digital input/output signals Optimises energy consumption thanks to occupancy function, window contact monitoring, demand- controlled switching of fan speeds and time-dependent setpoint specification Additional functions: automatic heating/cooling changeover, automatic switching on, setpoint com- pensation, free external cooling and other Mathematical functions for universal inputs: subtraction, mean, min. and max. Eight freely assignable alarm conditions with a selectable status for the outputs for an alarm condi- tion Time and weekly calendar function (time software) Integration into building management system via BACnet router (MS/TP to IP) Parametrisation with ecoUnit382 room operating unit System bus: RS485 (BACnet MS/TP) Bus for operating unit: RS485 (VCPP) Technical data Ambient conditions Operating temperature 0...50 °C Humidity without condensation Max. 95% rh Inputs / outputs Active inputs Analogue inputs U/(I) 0…10 V=, 2...10 V= Passive inputs Temperature sensor NTC 10k (-40…140 °C), Type 2 Resistance input 0…20 kΩ (for potentiometer) Digital input, open contact 100%/0% (ON/OFF) Virtual inputs BACnet AV object 4 × Outputs Triac switching outputs 0-I, PWM (24 V~, total 250 mA) Relay switching outputs Normally-open contacts (250 V~/24 V=, 2 A) Normally-open contacts (250 V~, 10 A) Analogue outputs 3 × 0...10 V=, 2…10 V= (load ≥ 1 kΩ) Interfaces and communication Interface Room operating unit (RBG) 1 × RS485 for EY-RU 382 (VCPP) Communication BACnet MS/TP 1 × RS485 galv. isolated, ½ load Construction Dimensions W x H x D 147 × 115 × 57 mm 3 Electrical connection Screw terminals for cables from 0.34…2.5 mm 2 Power supply, bus and RBG connec- tion Pluggable screw terminals Standards and directives Type of protection 1) IP 00 (EN 60529) Protection class II (IEC 60536) 1) The type of protection is IP30...IP40 (depending on the cover in the cabinet) from the front side, if installed cor- rectly as per EN 60730-1 Product data sheet 94.300 Right of amendment reserved © 2015 Fr. Sauter AG 3.1 1/4 EY-RC301F005 EY-RC302F001
Transcript

EY-RC 301, 302: Room controller, ecos301, 302

How energy efficiency is improvedThe ecos 3 controller enables precise room climate regulation and thus ensures minimum energyconsumption in the room.

Features• Part of the SAUTER EY-modulo 3 system family (BACnet MS/TP)• Single-room controller for an energy-optimised room climate• BACnet room controller (B-ASC) for fan coil unit, chilled beam, chilled ceiling, radiator heater etc.• Individual adjustment of the room climate with the ecoUnit382 room operating unit (EY-RU 382)• Universal PI and/or binary controller sequence for all the analogue and digital input/output signals• Optimises energy consumption thanks to occupancy function, window contact monitoring, demand-

controlled switching of fan speeds and time-dependent setpoint specification• Additional functions: automatic heating/cooling changeover, automatic switching on, setpoint com-

pensation, free external cooling and other• Mathematical functions for universal inputs: subtraction, mean, min. and max.• Eight freely assignable alarm conditions with a selectable status for the outputs for an alarm condi-

tion• Time and weekly calendar function (time software)• Integration into building management system via BACnet router (MS/TP to IP)• Parametrisation with ecoUnit382 room operating unit• System bus: RS485 (BACnet MS/TP)• Bus for operating unit: RS485 (VCPP)

Technical data

Ambient conditionsOperating temperature 0...50 °CHumidity without condensation Max. 95% rh

Inputs / outputsActive inputs Analogue inputs U/(I)

0…10 V=, 2...10 V=Passive inputs Temperature sensor NTC 10k (-40…140 °C), Type 2

Resistance input 0…20 kΩ (for potentiometer)Digital input, open contact 100%/0% (ON/OFF)

Virtual inputs BACnet AV object 4 ×Outputs Triac switching outputs 0-I, PWM (24 V~, total 250 mA)

Relay switching outputs Normally-open contacts (250 V~/24V=, 2 A)Normally-open contacts (250 V~, 10A)

Analogue outputs 3 × 0...10 V=, 2…10 V=(load ≥ 1 kΩ)

Interfaces and communicationInterface Room operating unit (RBG) 1 × RS485 for EY-RU 382 (VCPP)Communication BACnet MS/TP 1 × RS485 galv. isolated, ½ load

ConstructionDimensions W x H x D 147 × 115 × 57 mm3

Electrical connection Screw terminals for cables from0.34…2.5 mm2

Power supply, bus and RBG connec-tion

Pluggable screw terminals

Standards and directivesType of protection1) IP 00 (EN 60529)Protection class II (IEC 60536)

1) The type of protection is IP30...IP40 (depending on the cover in the cabinet) from the front side, if installed cor-rectly as per EN 60730-1

Product data sheet 94.300

Right of amendment reserved © 2015 Fr. Sauter AG 3.1 1/4

EY-RC301F005

EY-RC302F001

Energy class VIII = 5 %acc. EU 811/2013, 2010/30/EU,2009/125/EG

Degree of contamination II (EN 60730-1)Environment class 3K3 (IEC 60721-3-3)

CE conformity according to EMC directive 2004/108/ECLow-voltage directive 2006/95/EC

Product standards Automatic electric regulating andcontrol devices

EN 60730-1

Special requirements for tempera-ture-dependent control devices

EN 60730-2-9

Electromagnetic compatibility for resi-dential premises (type 1)

Emission:EN 60730-1 (Type 1)Immunity:EN 60730-1 (Type 1)

Overview of typesType EY-RC301F005 EY-RC302F001

Power supply 24 V~ ±10%, 50/60 Hz24 V= ±10%SELV, HD 384, Class II, 48 VA

230 V~, ±10%, 50/60Hz

Power consumption Max. 10 VA Max. 13 VA

Output for power supply − 24 V~, max. 6 VA

Number of I/Os 13 16

Passive inputs 3 4

Active inputs 3 2

Triac − 2 (24 V~)

Relay 4 (2 A) 4 (2 A), 1 (10 A)

Weight 268 g 550 g

AccessoriesType Description

0940183005 Memory plug-in for ecos 3 controller (contains 5 pcs of 0940183001)

Suitable productsAXT*** / AXS*** Thermal actuators for unit valves (see product data sheets)AXM*** Motorised actuators for unit valves (see product data sheets)EGT*** External temperature sensors (active or NTC 10k) (see product data sheets)EGT638 Room temperature sensor (with adjuster)EGH102 Dew point monitor with sensor0313367*** Cable-type sensor (NTC 10k)0450232001 Outside temperature sensor (NTC 10k)

Description of operationSee manual (I) “ecos 3 - parametrisation”.

Intended useThis product is only suitable for the purpose intended by the manufacturer, as described in the “De-scription of operation” section.All related product regulations must also be adhered to. Changing or converting the product is not ad-missible.

Engineering notesSee manual (I) “ecos 3 - parametrisation”.

Product data sheet 94.300

2/4 3.1 Right of amendment reserved © 2015 Fr. Sauter AG

Fitting

Additional informationFitting instructions P100012806Manual (I): ecos 3 - room controller - parametrisation D100233615

DisposalThe local, currently valid laws must be observed when disposing of the device.

Connection diagramEY-RC301F005

Relay 2 A

AO 0…10V24 V~(10 VA)

24V~

(10...48 VA)

N L

MM LS02AO1

03AO2

04AO3

08R2

12R4

Power

05 06R1

07 09 10R3

11

Digital Output (4x)Analog Output (3x)

RT1

14

RT

RT

AIRT

RT2

15

RT3

16

AI1

18

AI2

19

AI3

20

RU1

21

RU2

22

RU3

23

RU4

24

01

13 17

AI 0…10V EY-RU382

Passiv Input (3x) Analog Input (3x) Room Operating Unit

NTC

10 kΩ

0…10 V

C D-

26

D+

27

n.c.

28

RS-485

BACnet MS/TP

120Ω(LT)

N N NL/LS

R R RR RAO

Actu-ator

NTC (10 kΩ), DI ( ), RI (Ω)

Poti

CAT5/CAT6

LED, Status LED (2x), RS-485

AI

0…20 mA

0…10 V

Shunt

EY-RU382

+V

1 2 3 4

Product data sheet 94.300

Right of amendment reserved © 2015 Fr. Sauter AG 3.1 3/4

EY-RC302F001

120(LT)

CAT5/CAT6

230 V~

04R1

03

Power In

Triac 250 mA

LS` :max. 6 VA

24 V

Digital Output (7x)

RT1

20

AO1

16

A 2O

17

AO3

18

RT2

21

RT3

22

RT4

24

AI1

25

AI2

26

RU1

27

RU2

28

RU3

29

RU4

3015 19 23

AI 0…10 V EY-RU382

Anlaog Output (3x) Passiv Input (4x)Analog

Input (2x) Room Operating Unit

AO 0…10 V

C

31

D-

32

D+

33

n.c.

34

RS-485

BACnet MS/TP

N N NL/LS L/LS L/LS

R R RR R

AO

Actu-ator

NTC (10 k ), DI ( )), RI (

LED, Status

L

L

N

N

AI

0…10 V

LED (2x), RS-485

RT

RT

RT

NTC

10 k

Poti

05R2

06R3

07 08R4

09 10R5

Relay2 A

Relay2 A

Relay10 A

11T1

T T

12LS`

13T2

14LS`

LS` LS`

~

01 02LS`

Power Out

AI

0…20 mA

0…10 V

Shunt EY-RU382

+ V

1 2 3 4

Dimension drawing147

115

120

57

Product data sheet 94.300

4/4 3.1 Right of amendment reserved © 2015 Fr. Sauter AG

Fr. Sauter AGIm Surinam 55CH-4016 BaselTel. +41 61 - 695 55 55www.sauter-controls.com

Fr. Sauter AGIm Surinam 55CH-4016 BaselTel. +41 61 - 695 55 55www.sauter-controls.com

Fr. Sauter AGIm Surinam 55CH-4016 BaselTel. +41 61 - 695 55 55www.sauter-controls.com


Recommended