• Calibration Lab – ILAC ( ISO / IEC 17025 )
• Factory Automatic QC Inspection System ─ According to IEC 61298 – ISO 9001
www.eyc-tech.com
Temperature / Humidity / Dew Point / Pressure / Flow / Air Velocity / CO . CO2 . PM2.5 / Signal Transmitter
OEM / ODM Service & Distributor WantedMeasuring Specialist
www.eyc-tech.com
• Measuring Range : 0.2 ... 100 bar• Electric Connection : DIN43650• Accuracy : ± 0.1 % of F.S.• Connection : Internal thread 1/4-18NPT• Output : 4 ... 20mA• Signal Connection : 2-wire• Application : Petrochemical industry / Chemical industry
Industrial Grade Differential Pressure Transmitterr
P064
• Sensor Type : Piezoresistive diaphragm• Measuring Range : 0 ... 20 bar• Output : 4 … 20mA• Accuracy : ± 0.5 % of F.S.• Signal Connection : 2-wire• Housing : SUS 316L• Application : Mechanical equipment / Water plant / Air equipment / Chiller unit
Differential Pressure Transmitterr
P063
• Measuring pressure for liquid• Relative Pressure : 0.1 ... 400 bar• Accuracy ( at 20 °C ± 5 °C ) : ± 0.5 % of F.S.• Housing material : SUS 316• Isolated diaphragm material : SUS 316L• Application : Process equipment / Food and Pharmaceutical Industry / Machine devices
Pressure Transmitter
P045
Piezoresistive Pressure Transmitter
• Sensor Type : Piezoresistive diaphragm• Measuring Range : Absolute pressure:0 ... 10 bar Relative pressure:0 … 40 bar• Output : 4 … 20 mA• Signal Connection : 2-wire• Accuracy : ± 0.3 % of F.S.• Application : Instrument manufacturing / Machine devices / Water plant / Air devices
P043
Air Quality LED Monitor
• Monitor PM2.5, CO2, temperature & humidity via RS-485 at the same time. • Display Type : High Brightness LED• Accuracy : ± 0.4 ℃ ; ± 3 %RH ( at 20 ... 90 %RH ) ; ± 40 PPM ± 3 % of Reading ; ± 10 μg/m³ ± 5% of Reading• Application : Industrial Process / Plant / IDC / Clean room / Storage / Hospital / Office building / Agriculture
DMB05
PM2.5 Air Quality Monitor
• Real-Time Data of PM2.5, CO2, temperature & humidity• Measuring Range : 0 ... 50 ℃ ; 0 ... 100 %RH ; 0 ... 2000 PPM ; 0 ... 500 μg/m³ • Accuracy : ± 0.4 ℃ ; ± 3 %RH ( at 20 ... 90 %RH ) ; ± 40 PPM ± 3 % of Reading ; ± 10 μg/m³ ± 5% of Reading• Application : Indoor air quaility / HVAC / Air ventilation system / Department store
TGP03 / THP03
2018 New Product Release
P01
www.eyc-tech.com
2018 New Product Release
• Resistance : PT 100 Ω / PT 500 Ω / PT 100 Ω• Output : PT 100 Ω / 4 ... 20 mA• Accuracy : A ± ( 0.15 + 0.002 | t | ) B ± ( 0.3 + 0.005 | t | )• Ex d IIC T6 IP68 Ex tD A21 T100 ℃ IP68• Application : Dust environment / Chemical factory
EX temperature Transmitter
EX-R1ATEX
• Input : PT 100 Ω ( 3 wire )• Output : 4 ... 20 mA DC ( 2 wire )• Accuracy : Humidity : ± 2 %RH Temperature : ± 0.2 K at 23 °C• Operating Temperature Range : -40 ... +80 °C• Application : Aerospace Industry / Pharmaceutical Industry / Armament Industry / Metal Surface Grinding
Temperature & Humidity Transmitter
THS14EXATEX• 0 ... 10 bar for level detecting • Output : 4 ... 20 mA • Accuracy : ± 0.5 % of F.S.• Cable length : 3 ... 102 meter ( customize ) • Application : Drinking water equipment / Flow current
L053
Submersible Pressure Transmitter
• Measuring range : Water : 1 ... 200 cm/s Oil : 3 ... 300 cm/s Air : 20 ... 2000 cm/s• Supply voltage : 24 ± 20 %vdc• Current consumption : < 40 mA ( 24vdc )• Operating temperature : -40 ... 85 °C• Application : Ventilation / Hydraulic pressure
Thermal Flow Controller
FTC04
• Bearing : Stainless steel ball bearing / Tungsten arbide / Ceramic journal bearing• Low flow measurement• Accuracy : Better than ±1% of reading ± 0.5% / ±0.2% selectable • Nominal Diameter : DN4 ... DN40 • Application : Semiconductor integrated circuit Petrochemical / Pharmaceutical /
Turbine Flow Meter
FFM04
• Input type : Thermo Differential Pressure Module• Measuring range : 0 ... 500 pa• Accuracy ( at 25 ℃ ) : ± 0.5 % of F.S.• ModBus : RS-485• Physical switch : mbar / Pa / hPa / kPa / mmH2O / mmWS / inH2O / mmHg• Square root function • Application : Monitor differential pressure of Cleanroom / Filter environment / Air duct
Average Flow Measuring Tube + Differential Pressure Transmitter
AFMT+PHM33
P02
www.eyc-tech.com
Temperature / Humidity
• PT100 / NTC10 K ; 0 ... 100 %RH• Output : temp. : PT100 Ω; humidity : 0 ... 10V ; 4 ... 20 mA• Accuracy : Humidity : ± 3 %RH of F.S. ; Temp. : ± 0.3 ℃ • RS-458 ; 0 ... 10V ( 3-wire ) ; 4 ... 20mA ( 2-wire )• Application : HVAC / Machine facility
THS17
Temperature & Humidity Transmitter
• 0 ... +50 ℃ ; 0 ... 100 %RH• Output : 4 ... 20 mA / 0 ... 10 V ; Optional output : passive temp. : PT100 / PT1000• Accuracy : Humidity : ±2 % RH ( 20 ~ 80 % RH ) ; Temperature : ± 0.3℃• Application : HVAC process / Air conditioning Environmental ventilation control
CMOS MEMS TechnologyMost Economy
THS130/140
Temperature & Humidity Transmitter
• 0 ... + 50 ℃ ; 0 ... 100 %RH• Analogue output / RS-485• Accuracy : Humidity : ± 3 % RH ( 20 ... 90 % RH ) ; Temperature : ± 0.4 ℃;• Application : HVAC building & HVAC air conditioning control
THR23
Temperature & Humidity Transmitter
• -40 ... +80 ℃ ; 0 ... 100 %RH• Analogue output / RS-485 ( Programmable )• Accuracy : Humidity : ± 2 %RH ;• Temp. : ± 0.15 ℃ ± 0.002 ℃ x Tactual• Application : Outdoor temp. & Humidity monitor
THS307
Temperature & Humidity Transmitter
• - 40 ... + 150 ℃ ; 0 ... 100 %RH ; 10 bar• Analogue output / RS-485 ( Programmable )• Accuracy : Humidity : ± 2 %RH;• Temp. : ± 0.15 ℃ ± 0.002 ℃ x Tactual• Application : Laboratory / Pharmaceutical
THS30X
Temperature & Humidity Transmitter
• -40 ... + 200 ℃ ; 0 ... 100 %RH ; 10 bar• Analogue output / RS-485 ( Programmable )• Accuracy : humidity : ± 1.2 %RH ; Temp. : ± 0.15 ℃ ± 0.002 ℃ x Tactual• Dew point, absolute humidity etc ...• Rugged aluminum alloy, IP67• Application : Semiconductor / Pharmaceutical / Industry
Temperature & Humidity Transmitter
THM80X
P03
www.eyc-tech.com
Temperature / Humidity / Dew Point
• Input : PT 100 Ω • Output : 4 ... 20mA • Accuracy : ± 0.1 % of F.S.• Application : HVAC / Agriculture / Water power
Temperature Transmitter
TP02
• Input : PT 100 Ω• Output : 4 ... 20 mA • Accuracy : ± 0.1 % of F.S.• RTD Head-mounting• Application : Cooling system / Integrated with thermocouple
RTD Temperature Transmitter
TP01
• Input : PT 100 Ω • Output : 4 ... 20 mA , 2 wire• Accuracy : ± 0.5 % of F.S.• Integrated design with anti-condensation function• Application : Food / Pharmaceutical / Machinery manufacturing
Temperature Transmitter
TP04
• -80~+80 ℃ / -80~+60 dp℃• Analogue output / RS-485 ( Programmable )• Accuracy : Dew point:±3 dp ℃±(0.02%F.S./℃); Temp. : ±0.15℃±0.002℃ x Tactual Frost point, absolute humidity etc ...• Application : Industrial process / Pharmaceutical Industry
Dew Point Transmitter
THM86/87
• -100 ... + 60 dp℃ ; 16 bar• Analogue output • RS-485 ( Programmable )• Accuracy : ±2 dp ℃ ± ( 0.02%F.S./℃ )• Application : Adsorption / Freeze dryer / Dehumidifier
High Pressure Dew Point Transmitter
THS88
• 0 ... + 50 ℃ ; 0 ... 100 %RH ; 0 ...2000PPM• Output : 4 ... 20 mA / 0 ...10 V• Accuracy : Humidity : ± 3 % RH ( 20 ... 90 %RH ) ; Temperature : ± 0.4 ℃; CO2 : ± 40 PPM ± 3 % of reading• Application : Monitoring the air quality in indoor environments
THG03
Temperature & Humidity Transmitter
P04
www.eyc-tech.com
Air velocity / Gas
Gas Monitoring Transmitter
• Input : T / H / CO / HCHO / VOC• Analogue output / RS-485 ( Programmable )• Accuracy : Temp. : ± 0.3 ℃ Humidity : ± 3 % RH CO : ± 3 % of F.S. HCHO : ±5 % of F.S. VOC :±5% of F.S.• Application : Monitor parking lot / Factory Air quality
GTH53
• Measuring media : air• Differential pressure transmitter• Average flow measuring tube length : 2 ... 40” • Operating pressure : max. 10 bar• Operating temperature : 250 ℃• Stainless steel 316• Application : Exhaust gas removal
Average Flow Measuring Tube +Differential Pressure Transmitter
AFMT+PMD33
P05
• 0 ... + 20 m/s;0 ... 10 V
• Accuracy : ± 5 % of F.S.
• Economical type
• Application : HVAC air process /
Clean room / Laminar flow
Hot wire Air Velocity Transmitter
FTS07
• 0 ... +20 m/s• Analogue output• Accuracy : ± 3 % of F.S.• IP54 • Switching analogue output by dip switch• Application : Light industry process / HVAC Building / Factory
FTS14
Air Velocity Transmitter
• 0 ... +40 m/s• Analogue output / RS-485 ( Programmable )• Accuracy : ± 2 % of F.S.• Auto-zero key, IP54 • Switch for physical quantity:[m/s]、[ft/s]...• Application : Light industry process / Pharmaceutical / Paper Industry
Air Velocity Transmitter
FTS34/35
• 0 ... + 120 m/s ; 0 ... + 120 ℃ • Analogue output / RS-485 ( Programmable ) • Accuracy : ± 1.5 % F.S. ; temp. : ± 0.3 ℃ • Rugged aluminum alloy, IP67• Application : Industrial process / Chemical / Pharmaceutical / Iron and steel industry
Thermo Air Velocity Transmitter
FTM84/85
www.eyc-tech.com
Gas / Pressure / Signal
• Input : Current / Voltage / RTD / TC / Potentiometer / Linear Resistance• Local display, Setting by key pad• Analogue output / RS-485 / Frequency / Relay• Isolation : Power supply / Analogue Input & Output / RS-485• Application : Distribution cabinet / Industrial facility
Signal Converter
DPT02
• Input : Current / Voltage / RTD / TC Potentiometer / Linear Resistance / • Analogue output / RS-485 / Relay• Isolation : Power supply / Analogue Input & Output / RS-485• Display range : 5 digits, 7-segmant• Application : Distribution cabinet
Signal Display Monitor
DPM02
• 330° turnable ; the direction of panel is changeable; good monitoring • Intput : 4 ... 20 mA • Accuracy : 0.2 % of F.S.• Electrical connection : DIN 43650 plug / M12 connector• Application : Steel Industry / Water Plants Environmental Engineering
Integrated Signal Indicator
SD05
• Input : CO, 0 ... 500 PPM• Analogue output / RS-485 ( Programmable )• Accuracy : ± 3 % of F.S. • Application : Parking lot / Factory / Building
CO Transmitter
GM33/34
• CO2 : 0 ... 2000 PPM• Analogue output / RS-485 ( Programmable )• Accuracy : ± 40 PPM ± 3 % of reading• Non-dispersive Infrared ( NDIR )• Indoor monitor• Application : HVAC / Air conditioning / Museums / Supermarkets / Data centers / Wharehouses
CO2 Transmitter
GS23
• Input : CO2, 0 ... 10000 PPM• Analogue / RS-485 ( Programmable )• Accuracy : 400 ... 2000 PPM: ± 40 PPM ± 3 % of reading Other : ± 50 PPM ± 3 % of reading• Applicatrion : Parking lot / Greenhouse / Agriculture
CO2 Transmitter
GS43/44
P06
www.eyc-tech.com
Factory Automatic QC Inspection System ( IEC 61298 )
Dew Point ( - 80 dp°C ... + 60 dp°C )
SD05+THS88 Dew Point Transmitter
PC-based & human machine interface Automatic QC inspection sheet printing
Automatic QCtesting report
DAQ & RS-485
HMI
Dew Point MirrorRH System 973
Humidity Generator
Thunder 3900
with
Air Velocity ( 120 m/s )
Device under test (DUT)EYC FTS84/85
DAQ
VFD ( Inverter)
PC
Inspection System
Wind Tunnel
P07
www.eyc-tech.com
Calibration Range
Dew Point System
temp. : - 80 ... + 60 ℃
temp. : + 60 °C ... -80 °C
temp. : 0.14 °C ... 0.97 °C
Temperature System Humidity System
temp. : - 40 ... + 300 ℃Single point & Space calibration temp. : 0 ℃ ... 70 ℃ Humidity : 10 %RH ... 95 %RH
Single point
temp. : 0.11 °C ... 0.17 °C
Humidity : 0.11 %RH ... 0.55 %RH
temp. : 0.017 ... 0.094 ℃
FlukeMetrology Well
-95℃
Dew Point MirrorRH System 473
Dew Point MirrorRH System 473
Humidity GeneratorThnder 2500
Humidity GeneratorThunder 3900
CalibrationRange
CalibrationMeter
Calibration System
SmallestUncertainty
Chino standard Platinum
Thermometer
ILAC Mutual Recognition Arrangement Lab
Temperature & HumidityDew Point Calibration Lab
• International Lab Alliance Recognition ─ TAF ( ISO / IEC 17025 )
• Accreditation no. : 3032
• Fit for Global Application
• Comparable to National Grade Laboratory
• Professional calibration staff
• Wide range of high-precision measurement
♦ Temperature : - 40 ... + 300 °C
♦ Dew point / frost point : - 80 ... + 60 °C
♦ Relative humidity : 10 ... 95 % RH
• Extremely low calibration uncertainty, quickly repeat testing, apply to
the calibration of the temperature & humidity / dew point instrument
International recognition, fit for Global application
▲ TAF Certification
P08
Put Pressure On
Pressure Generator
Expansion Platform0 ... 10 MPa
Additel ADT 681Digital Pressure Gauges
Data record
Check
STD.
Additel ADT 918 Pneumatic Pressure
Test Pump
+
Pressure System
Diffuser
Exhaust
Intake
Compressor
Velocity ControlData Record
Record / Control
Air Velocity System
YOKOGAWADiffrential Pressure Transmitter
Pitot tube
Air Velocity / Pressure Lab
│ Capability
│ Capability
Standard Check
0 ... 40 m/s eYc FTS84 Air Velocity Transmitter
40 ... 120 m/s Pitot Tube Differential Pressure Transmitter
0.25 ... 60 m/s
Calibration
Meter
Calibration
Range
Smallest
Uncertainty 0.04 m/s ... 0.90 m/s
Additel ADT 681
Digital Pressure Gauges
Wika Laboratory
Grade Pressure Gauge
Relative pressure 10 ... 7000 kPa
Absolute pressure 20 ... 170 kPa
Relative pressure 0.15 kPa
Absolute pressure 1.5kPa ... 7 kPa
Standard Check
Calibration
Meter
Calibration
Range
Smallest
Uncertainty
www.eyc-tech.comP09
Gas / Flow Lab
│ Capability
│ Capability
Standard Check
Standard CO / CO2eYc CO / CO2
Transmitter
CO : 0 ... 500 μmol/mol(ppm)
CO2 : 0 ... 10000 μmol/mol(ppm)
Calibration
Meter
Calibration
Range
Smallest
Uncertainty
CO : 5.4 ... 23.4 μmol/mol
CO2 : 17 ... 274 μmol/mol
Standard Check
Calibration
Meter
Calibration
Range
Smallest
Uncertainty
YOKOGAWA
Magnetic
Flowmeter
TRICOR
Coriolis
Flow Meter
Flow Rate : 2.4 m3/h ... 30.0 m3/h ( 40 L/min ... 500 L/min)Velocity : 0.2 ... 3 m/s
Flow Rate : U = 0.6 %Velocity : U = 0.07 m/s
Standard CO & CO2
STD.Span Gas
CO / CO2
Regulator
Regulator
Chamber
DUT.
( Device Under Test )
Vogtlin Thermal Mass Flow Meters & Controllers• CO ( 1 L )• CO2 (1 L)• N2 ( 10 L )
eYc
CO / CO2 Transmitter
CHECK
1
Control Value
Control Value
Vent
By Pass
Gas Dilutor
Zero GasN2
Data Record
CO / CO2 / Gas System
Flow System
DUT.
( Device Under Test )
YOKOGAWA
Magnetic Flowmeter
STD.
MonitorTemperature & Pressureby eyc transmitter
Circulation Water Flow Direction
Tube 1.5”
TRICOR
Coriolis Flow Meter
CHECK
eyc Water FlowTransmitter
valve
Water Flow Control
Data Direction
Data Direction
Data Direction
Water Tank
eyc RTD TC & Heater
MonitorTemperature
Heater
Tube 3”
Data Record
www.eyc-tech.com P10
Temperature &Humidity Transmitter
Multifunction Signal Converter
Dew PointTemperatureTransmitter
Air VelocityTransmitter
Multifunction Signal Display Monitor
CO / CO2Transmitter
Differential Pressure Transmitter
Industrial Factory / HVAC building / Smart City
Sensor / Transmitter / Signal converter & monitor
A.I. GatewayGateway
IIoT Hub Cloud Platform Cloud Storage
D.I. & A.I.
D.O. & A.O.
SCADAHDMI / MONITORModbus Master
Data LoggerTerminal
Monitor & Control
D.I. & A.I. D.O. & A.O.
WI-FIModbus TCP
MachineLearning
Edge Computing
RS-485 & WiFi, BT, ZigBee, Sub-G, LTE, 4G, 5G
www.eyc-tech.com
EYC AIoT Monitor Cloud System