8
Calibration Lab ILAC ( ISO / IEC 17025 ) Factory Automatic QC Inspection System According to IEC 61298 ISO 9001 OEM / ODM Service & Distributor Wanted www.eyc-tech.com MEASURING SPECIALIST eYc, Your Solution Provider | Temperature | Humidity | Pressure | | Dew Point | Flow | CO, CO 2 , PM2.5 | | Air Velocity | Signal Transmitter |
Transcript
Page 1: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

Calibration Lab ILAC ( ISO / IEC 17025 ) Factory Automatic QC

Inspection SystemAccording to IEC 61298

ISO 9001

OEM / ODM Service & Distributor Wanted

www.eyc-tech.com

MEASURINGSPECIALIST

eYc, Your Solution Provider

| Temperature | Humidity | Pressure | | Dew Point | Flow | CO, CO2, PM2.5 || Air Velocity | Signal Transmitter |

Page 2: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

SD06 Series Transmitter

NO1

Best PerformanceProduct Set

HVAC SystemPMM33/DPM02/AFMT/AFMS160

Page 3: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

SD06 Series Transmitter

ManufacturingProcess

NO2

SD06-MP/DPM02/AFMT/AFMS-160

Exhaust GasEmission System

NO3

PHM33/AFMT/AFMS-160

Page 4: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

Temperature / Humidity / Signal

www.eyc-tech.com

• -40 ... + 200 ℃ ; 0 ... 100 %RH ; 10 bar• Analog output / RS-485 ( Programmable )• Accuracy : Humidity : ± 1.2 %RH ; Temp. : ± 0.15 ℃ ± 0.002 ℃ x tactual• Dew point, absolute humidity etc ...• Rugged aluminum alloy, IP65• Application : Semiconductor / Pharmaceutical / Industry

Temp. & Humidity Transmitter

THM80X

• 0 ... + 50 ℃ ( THS301 ) ; - 40 ... +100 ℃ ( THS302 ) ; -40 ... +80 ℃ ( THS304 / 307 ) ; 0 ... 100 %RH ; Proof pressure : 10 bar• Analog output / RS-485 ( Programmable )• Accuracy : Humidity : ± 2 %RH; Temp. : ± 0.2 ℃ ± 0.005 ℃ x tactual• Application : Laboratory / Pharmaceutical Outdoor temp. / Humidity monitor

THS30X

Temp. & Humidity Transmitter

• 0 ... +50 ℃ ; 0 ... 100 %RH• Output : 4 ... 20 mA / 0 ... 10 V ; Optional • Passive temp. : PT100 / PT1000• Accuracy : Temperature : ± 0.5℃ ; Humidity : ±5 %RH ( 30 ... 80 % RH )• Application : HVAC process / Air conditioning / Environmental ventilation control

THS130/140

Temp. & Humidity Transmitter

CMOS MEMS TechnologyMost Economy

• 0 ... + 50 ℃ ; 0 ... 100 %RH• Analog output / RS-485• Accuracy : Temperature : ± 0.5 ℃; Humidity : ± 5 %RH ( 30 ... 80 % RH ) ; • Application : HVAC building & HVAC air conditioning control

THR23

Temp. & Humidity Transmitter

• 0 ... + 50 ℃ ; 0 ... 100 %RH ; 0 ...2000PPM• Output : 4 ... 20 mA / 0 ...10 V• Accuracy : Temperature : ± 0.5 ℃; Humidity : ± 5 %RH ( 30 ... 80 %RH ) ; CO2 : ± 40 PPM ± 3 % of reading• Application : Monitoring the air quality in indoor environments

THG03

Temp. & Humidity Transmitter

Temp. & Humidity & Air velocityTransmitter

• Sensor : CMOS ( THE / TPE110120 ) ; RTD Platinum resistance ( FTE120 )• Passive T-sensor : PT100 Class A ; PT1000 Class A ( THE / TPE110120) • 0 ... + 50 ℃ ; 0 ... 100 %RH ;• Cond. : Double probe protection• Accuracy : ± 0.5 % of F.S.( THE / TPE110120 ) ; ±3 % of F.S.( FTE120 ) ; Certification : CE• Housing : PC , Fire-Proof, HB Class• Probe material : SUS 304 PC + Glass fiber, Temp. up to 120 ℃

OEMBulk sales 50pcs/Carton

THE/TPE110120/FTE120

SD03 ( Indicator )

SubmersiblePressure

PiezoresistiveDifferential

PressureTemperaturePiezoresistive

Pressure

SD06-L SD06-MPSD06-P SD06-T

SD06 Integrated Indicator Transmitter Series• Input : PT100 / Temp. / Pressure / Differential pressure / Level • Measuring range display : -9999 ... 99999 ; Output : 4 ... 20 mA / IP67 ; Linear accuracy : <0.2%• Application : Industrial Process Control /Laboratory Systems / Compressor / Petrochemical Industry / Chemical Industry

• Multiple input types : Pressure, Differential Pressure, Temperature, Flow, pH, Load Cell, etc. 2-wire loop design / Anti-interference design/ IP67

SD03+L051(Submersible Pressure Transmitter)

• Sensor type : Piezoresistive diaphragm• Measuring range : 0 ...10 bar• Output : 4 ... 20mA ; 2-wire ; IP68 ( L051 )• Linear accuracy : ± 0.5 % of F.S• Operating range : 0 ... 50 °C ; 0 ... 100 %RH

Page 5: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

Temperature / Humidity / Dew Point / Pressure

www.eyc-tech.com

• 0 ... 10 bar for level detecting • Output : 4 ... 20 mA • Accuracy : ± 0.5 % of F.S.• Cable length : 3 ... 102 meter ( customize ) • Application : Drinking water equipment / Flow current

L053

Submersible Pressure Transmitter

• Temp. & Humidity : MEMS• 0 ... + 50 °C ; 0 ... 100 %RH• Accuracy ( at 25 °C ) : Temp. ± 0.5 ℃ ; Humidity : ± 5 %RH ( 30 ... 80 %RH )• Signal Connection : RS-458 ; 0 ... 10V ( 3-wire ) ; 4 ... 20mA ( 2-wire )• Application : HVAC / Machine facility

THS17

Temp. & Humidity Transmitter

Piezoresistive Pressure Transmitter

• Sensor Type : Piezoresistive diaphragm• Measuring Range : Absolute pressure:0 ... 10 bar Relative pressure:0 … 40 bar• Output : 4 … 20 mA• Signal Connection : 2-wire• Accuracy : ± 0.3 % of F.S.• Application : Instrument manufacturing / Machine devices / Water plant / Air devices

P043

• Measuring pressure for liquid• Relative Pressure : 0.1 ... 400 bar• Accuracy ( at 20 °C ± 5 °C ) : ± 0.5 % of F.S.• Housing material : SUS 316• Isolated diaphragm material : SUS 316L• Application : Process equipment / Food and Pharmaceutical Industry / Machine devices

Pressure Transmitter

P045

• -80 ... +80 ℃ / -80 ...+60 dp℃• Analog output / RS-485 ( Programmable )• Accuracy : Dew point : ± 3 dp ℃ ± ( 0.02%F.S./℃ ); Temp. : ± 0.15 ℃±0.002 ℃ x tactual Frost point, absolute humidity etc ...• Application : Industrial process / Pharmaceutical Industry

Dew Point Transmitter

THM86/87

• Input : Capacitive Humidity Sensor & PT 100 Ω• - 80 ... + 60 dp℃ ; 16 bar• Analog output • RS-485 ( Programmable )• Accuracy : ± 2 dp ℃ ± ( 0.02%F.S./℃ )• Application : Adsorption / Freeze dryer / Dehumidifier

High Pressure Dew Point Transmitter

THS88 Plus

THM14EX

• Input : Capacitive Humidity Sensor & PT 1000 Ω • Output : 4 ... 20 mA ( 2 wire )• Accuracy ( at 25 °C ) : Temp. : ± 0.3 °C+0.002 °C x t actual Humidity : ± 2 %RH ( 15 ... 90 % )• Temp. Error : 0.2 %RH / ℃ • Application : Aerospace Industry / Semiconductor / Electronics / Steel Industry

Temp. & Humidity Transmitter

• Resistance : PT 100 Ω / PT 500 Ω / PT 1000 Ω• Output : PT 100 Ω / 4 ... 20 mA• Accuracy : A ± ( 0.15 + 0.002 | t | ) B ± ( 0.3 + 0.005 | t | )• Ex d IIC T6 IP68 Ex tD A21 T100 ℃ IP68• Application : Dust environment / Chemical factory

EX Temp. Transmitter

EX-R1

• Input : PT 100 Ω ( TP01 : 3 wire ) • Output : 4 ... 20 mA , 2 wire ( TP04 )• Accuracy : ± 0.5 % of F.S. ( TP04 ) ± 0.1 % of F.S. ( TP01 )• Integrated design with anti-condensation function ( TP04 )• RTD Head-mounting ( TP01 ) • Application : Food / Pharmaceutical / Machinery manufacturing / Cooling system / Integrated with thermocouple

Temp. & RTD Transmitter

TP04/TP01

150%

Speed Upgrade

Page 6: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

www.eyc-tech.com

Pressure / Air velocity

• Measuring range : 0 ... 20 m/s• Analog output• Accuracy : ± 5 % of F.S.• IP54 • Switching Analog output by dip switch• Application : Light industry process / HVAC Building / Factory

FTS14

Air Velocity Transmitter

• Measuring range : 0 ... 40 m/s• Analog output / RS-485 ( Programmable )• Accuracy : ± 2 % of F.S.• Auto-zero key, IP54 • Switch for physical quantity:[m/s]、[ft/s]...• Application : Light industry process / Pharmaceutical / Paper Industry

Air Velocity Transmitter

FTS34/35

• Measuring range : 0 ... 120 m/s Probe temperature range : 0 ... + 120 ℃ • Analog output / RS-485 ( Programmable ) • Accuracy : ± 1.5 % F.S. ; Temp. : ± 0.3 ℃ • Rugged aluminum alloy, IP65• Application : Industrial process / Chemical / Pharmaceutical / Iron and steel industry

Thermo Air Velocity Transmitter

FTM84/85

• Measuring Range : 0.1 ... 100 bar• Electric Connection : DIN43650• Accuracy : ± 0.1% of F.S.• Connection : Internal thread 1/4-18NPT• Output : 4 ... 20mA• Signal Connection : 2-wire• Application : Petrochemical industry / Chemical industry

Industrial Grade Differential Pressure Transmitter

P064

• Input type : Thermo Differential Pressure Module• Measuring range : 0 ... 500 pa• Accuracy ( at 25 ℃ ) : ± 0.5 % of F.S.• ModBus : RS-485• Physical switch : mbar / Pa / hPa / kPa / mmH2O / mmWS / inH2O / mmHg• Square root function • Application : Monitor differential pressure of Cleanroom / Filter environment / Air duct

Average Flow Measuring Tube +Differential Pressure Transmitter

AFMT+PHM33

Hot Wire Thermal Flow Controller

FTM06

• Type : PTC thermistor• Range : Water : 0 ... 1.5 m/s : Air : 0 ... 20 m/s• Output Signal : Analog : 4 ... 20mA / 0 ... 10V ; RS-485 ; IP67• Product Accuracy : 3% < 1.5 m/s ; 3% < 20 m/s• Application : Industrial process gas supply, consumption and dry flow monitoring

AFMS-160

S-type Pitot tube

• Output : Operating pressure : Max 10 bar Operating temperature : Max. 250 °C ; Temperature tolerance : 800°C• Installation connection : 12" below 3/4" PT movable thread 18" or more is 1" PT movable thread• Length : 25 ... 1500mm / Customization• Application match : P063&SD06+DPM02 or PHM33 or PMM33+DPM02

• Type : PTC thermistor• Measuring range : Water : 1 ... 200 cm/s Oil : 3 ... 300 cm/s Gas Flow : 20 ... 2000 cm/s• Supply supply : 24 ± 10 %VDC ; IP67• Current consumption : ≤ 60 mA• Operating temperature : -40 ... 85 °C• Application : Venting systems / Hydraulic

Thermal Flow Controller

FTC04

• Sensor Type : Piezoresistive diaphragm• Measuring Range : 0 ... 20 bar• Output : 4 … 20mA• Accuracy : ± 0.5 % of F.S.• Signal Connection : 2-wire• Housing : SUS 316L• Application : Mechanical equipment / Water plant / Air equipment / Chiller unit

Differential Pressure Transmitter

P063

Page 7: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

www.eyc-tech.com

Air velocity / Flow / Pressure / Gas

• Measuring range : 0 ... 20 m/s;0 ... 10 V• Accuracy : ± 5 % of F.S.• Economical type• Application : HVAC air process / Clean room / Laminar flow

Hot wire Air Velocity Transmitter

FTS07

Gas Monitoring Transmitter

• Input : T / H / CO / HCHO / VOC• Analog output / RS-485 ( Programmable )• Accuracy : Temp. : ± 0.3 ℃ Humidity : ± 3 % RH CO : ± 3 % of F.S. HCHO : ±5 % of F.S. VOC :±5% of F.S.• Application : Monitor parking lot / Factory Air quality

GTH53

• Input : Current / Voltage / RTD / TC Potentiometer / Linear Resistance / • Local display, Setting by key pad ( DPT02 )• Analog output / RS-485 / Relay / Frequency ( DPT02 )• Isolation : Power supply / Analog Input & Output / RS-485• Application : Distribution cabinet / Industrial facility

Signal Display MonitorSignal Converter

DPT02 / DPM02

• CO2 : 0 ... 2000 PPM• Analog output / RS-485 ( Programmable )• Accuracy : ± 40 PPM ± 3 % of reading• Non-dispersive Infrared ( NDIR )• Indoor monitor• Application : HVAC / Air conditioning / Museums / Supermarkets / Data centers / Wharehouses

CO2 Transmitter

GS23

• Input : CO2, 0 ... 10000 PPM ( GS43/44 )• Input : CO, 0 ... 500 PPM ( GM33/34 )• Analog / RS-485 ( Programmable )• Accuracy : 400 ... 2000 ± 40 PPM ± 3 % of reading ( GS43/44 )• Accuracy : ± 3 % of F.S. ( GM33/34 )• Applicatrion : Parking lot / Greenhouse / Agriculture / Factory / Building

CO2 / CO Transmitter

GS43/44GM33/34

• 330° turnable ; the direction of panel is changeable; good monitoring • Intput : 4 ... 20 mA • Accuracy : 0.2 % of F.S.• Electrical connection : DIN 43650 plug / M12 connector• Application : Steel Industry / Water Plants Environmental Engineering

Integrated Signal Indicator

SD05

330°210°

Air Quality LED Monitor

• Monitor PM2.5, CO2, temperature & humidity via RS-485 at the same time. • Display Type : High Brightness LED• Signal Output : RS-485 ; Protocol ; Interface : Modbus RTU ; Power : AC 230V / DC 24V, 5A• As the local situation and refer to CO2 indication standards to transfer the suitable emoticon• Refer to PMV indication to display the real-time body sensing.

DMB04

PM2.5 Air Quality Monitor

• Real-Time Data of PM2.5, CO2, temperature & humidity• Measuring Range : 0 ... 50 ℃ ; 0 ... 100 %RH ; 0 ... 2000 PPM ; 0 ... 500 μg/m³ • Accuracy : ± 0.5 ℃ ; ± 5 %RH ( 30 ... 80 %RH ) ; ± 40 PPM ± 3 % of Reading ; ± 10 μg/m³ ± 5% of Reading• Application : Indoor air quaility / HVAC / Air ventilation system / Department store

TGP03 / THP03

• Measuring media : air• Differential pressure transmitter• Average flow measuring tube length : 2 ... 40” • Operating pressure : max. 10 bar• Operating temperature : 250 ℃• Stainless steel 316• Application : Exhaust gas removal

Average Flow Measuring Tube +Differential Pressure Transmitter

AFMT+PMD33

TGP03Bargain Set

Page 8: eYc, Your Solution Provider MEASURING SPECIALIST · Level 2 - Calibration Laboratory ILAC/TAF(ISO/IEC17025) Calibration service & Automated quality inspection system Accreditation

www.eyc-tech.com

Level 2 - Calibration LaboratoryILAC/TAF(ISO/IEC17025)

Calibration service & Automated quality inspection system

AccreditationNumber 3032

Dewpoint

Pressure

Temperature

Humidity Flow

Air Velocity

CO / CO2

Data record

Put Pressure On

CheckCheck

STD.

DataRecord

Vogtlin Thermal Mass Flow Meters &

Controllers

Control Value

Span GasCO / CO2

Zero GasN2

Record / Control(0...120 m/s)

Diffuser

ExhaustIntake

Compressor

Data Record

ExclusiveCalibration

Lab.


Recommended