2020
www.olympia-electronics.com
GAS DETECTION SYSTEMS
The analog gas detection panels:
Can cooperate with 4-20mA detectors which operate
with 2 or 3 cables.
Space for lead batteries 2x12V/7Ah and power supply for the
recharge.
4, 8, 12 or 16 outputs for detectors.
5, 9, 13 or 17 programmable relay outputs.
LCD screen to properly inform the user of any event.
Easy to operate and programming with 6 keys.
Led indication for every error or alarm.
Waterproof gas detector of LPG & natural gas. Power supply fromfire detection panel.
BS-685, BS-686
Waterproof slave gas detectorwith a catalytic sensor type.
BS-375/WP/A, BS-376/WP/A
High quality electrochemical detectorof carbon monoxide.
BS-658
Analog gas detectors4-20mA antiexplosive type. With Catalytic or ElectrochemicalSensor Type.
TS293XX TS282XXTC100NAnalog gas detectors4-20mA antiexplosive type. With catalytic sensor type.
GAS DETECTION
Waterproof analog gas detector, 4-20mA.With Catalytic or Electro-chemical Sensor Type.
BS-304BS-308BS-312BS-316
Analog gas detection panelswith connection capability of4, 8, 12 or 16 detectors, 4-20mA
Detector lifetime 5 years
Consumption 0,5WSuitable for gas detection inparking lots and garages or boiler rooms.
Detector capable of detecting liquid gas,natural gas or gasoline andpetrol fumes
Suitable for cleaning facilities,chemical installations, gas stations,boiler room, paint plantsand other locations where there are gases.
Detector capable of detecting LPG,natural gas, ammonia, oxygen,carbon monoxide, hydrogen, and at least 100 types of explosive anddangerous gases
Detector capable of detectingLPG, natural gas, carbon monoxide, ammonia.
IP65 IP65
IP66 IP65 IP65
A-304 4 zone expansion unit
ANALOG GAS DETECTION SYSTEMS
II 2G
Ex d IIC T6 Gb, -20°C ≤ Ta ≤ + 60°C
II 2G
Ex d IIC T6 Gb, -20°C ≤ Ta ≤ + 60°C
IP55
Detection of LPG ornatural gas-methane
Power supply 10-30V DC
Technical specifications for the gas detection panels
Power Supply
Consumption
Battery Type
Charge Circuit
Outputs
Wrap protection class
Operating temperature range
Humidity
Weight
Produced in accordance with
Warranty
Dimensions
220-240V AC / 50-60HZ
23W / 60VA
12V / 7Ah Pb or 2X12V / 7Ah
Power supply 13.8V / 500mA
17 programmable relays (5A/230V AC), Standard output 20V / 300mA
IP30
5 - 40°C
Up to 95% humidity
445 x 345 x 95 mm
6160gr.
EN 62368, EN 61000-6-1, EN 61000-6-3
2 years
BS-3044 detectors
4-20mA
BS-3088 detectors
4-20mA
BS-31212 detectors
4-20mA
BS-31616 detectors
4-20mA
Autonomous carbon monoxide gas detector with 3V lithium battery.
SE-325EC
Autonomous gas detection devicesof LPG with fire detection zone and output relay.
BS-694, BS-695
With catalytic sensor typeand 230V AC
Electrochemical Sensor Type
Battery 3V/1400mA
Autonomous gas detection devicesof LPG with fire detection zone andoutput relay, siren and beacon.
BS-690, BS-691
With catalytic sensor typeand 230V AC
IP40 IP40 IP42
Waterproof slave gas detectorwith a catalytic sensor type.
BS-377/WP/A, BS-378/WP/A
Slave luminary withbuzzer indication.
BS-527
Can cooperate with any detectionpanel that includes a 12-24VDC output.
Waterproof slave luminarywith buzzer indication.
BS-527/WP
Can cooperate with any detectionpanel that includes a 12-24VDC output.
Detection of LPG ornatural gas-methane
Power supply 230V AC
Distributor
F-003-000
Europeanmanufacturer
www.olympia-electronics.com
The company is certified by: