of 26
7/27/2019 F700 Version-Up Presentation
1/26
PVH-???-###PVH-???-###
Mitsubishi Electric Automation, Inc.F700 Version Up Series VFD
Empowering Greater Overall Equipment Effectiveness
Delivering Lower Total Cost of Ownership
Overview
New Features
7/27/2019 F700 Version-Up Presentation
2/26
MODEL CONFIGURATION
Inverter type
Model lineupApplied Motor
kW 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185 220 250 280 315 355 400 450 500 560Three-phase
200V class
FR-F720--NA - - - - - - - - - - - -
Three-phase
400V class
FR-F740--NA
Danfoss
ABB
Yask.
7/27/2019 F700 Version-Up Presentation
3/26
NEW FEATURES
Pre-Charge Function used with PID control
Detection of Current Input choose reaction
Second PID function RT input triggers
Direct Setting for PID set-point on FR-PU07-01
Units Indicator for PID control CFM, GPM, PSI
Three Line Selectable Monitor on FR-PU07-01
Hand/Auto Indication on FR-PU07-01
Built in PLC download pre-config. pump functions Two Option Ports expand available I/O points
Built in BACnet Mitsubishi / ABB / Trane
7/27/2019 F700 Version-Up Presentation
4/26
NEW MANUALS
7/27/2019 F700 Version-Up Presentation
5/26
Ideal for Pumps
Pre-charge function (Pr.760 to Pr. 769)
This function is to drive the motor at a certain speed before starting PID
control
The motor is operated at Pr. 127 PID control automatic switchover
frequencyat start until a pre-charge ending condition is satisfied
PID control starts after a pre-charge ending condition is satisfied This function is useful for a pump with a long hose
Without this function, PID control would start before the pump is filled
with water, and proper control would not be performed
Pre-charge function is also valid for a start after the PID output
suspension (SLEEP). PID output suspension (SLEEP) function is not
performed until the pre-charge operation ends
7/27/2019 F700 Version-Up Presentation
6/26
Ideal for Pumps
Pre-charge Operation (Pr.761)
When the measured amount reaches the pre-charge ending level
7/27/2019 F700 Version-Up Presentation
7/26
Ideal for Pumps
Pre-charge Operation (Pr. 762)
When the elapsed time reaches the pre-charge ending time
7/27/2019 F700 Version-Up Presentation
8/26
Ideal for Pumps
Pre-charge Operation
When the signal is input to end the pre-charge operation
7/27/2019 F700 Version-Up Presentation
9/26
Detection for current input (Pr. 573, Pr. 777, Pr. 778)
7/27/2019 F700 Version-Up Presentation
10/26
Detection for current input (Pr. 573, Pr. 777, Pr. 778)
7/27/2019 F700 Version-Up Presentation
11/26
Second PID function (Pr.753 to Pr. 758, Pr.765 to Pr.769)
Possible to exchange the PID control loop by the RT terminal.
Direct setting for PID set-point
Easy to change the PID set-point with the
parameter unit (FR-PU07-01).
Direct setting menu is displayed by the one
button (FUNC button).
7/27/2019 F700 Version-Up Presentation
12/26
Unit Indicator for PID Control
Possible to exchange the PID control loop by the RT terminal.
Possible to change the unit indicator for the PID
monitors and PID parameters on the parameter
unit (FR-PU07-01).
Ex.
PSI(Pound-force per Square Inch)
GPM(Gallon per Minute)
CFM(Cubic Feet per Minute)
Ideal for Fans and Pumps
7/27/2019 F700 Version-Up Presentation
13/26
Ideal for Fans and Pumps
Three line selectable monitor
Possible to display the value of the selected
monitor at the three line monitors.
The parameter unit (FR-PU07-01) is required.
Operation key and operation mode indication
The operation key and the
operation mode indication of the
parameter unit (FR-PU07-01) are
HAND and AUTO.
7/27/2019 F700 Version-Up Presentation
14/26
Built-in PLC
Ideal for Fans and Pumps
Ability to create custom control programs- 4K steps of memory
- Download pre-configured pump functions
7/27/2019 F700 Version-Up Presentation
15/26
Two Option Ports Permitted
Expand available I/O points such
as digital inputs and outputs,
Form C relays and analog
Ideal for Fans and Pumps
Only one Comm. Card at a timeTwo of the same I/O Cards not permitted
7/27/2019 F700 Version-Up Presentation
16/26
Built in BACnet MS/TP X...
7/27/2019 F700 Version-Up Presentation
17/26
Built in BACnet MS/TP
7/27/2019 F700 Version-Up Presentation
18/26
Built in BACnet MS/TP
7/27/2019 F700 Version-Up Presentation
19/26
Built in BACnet MS/TP
7/27/2019 F700 Version-Up Presentation
20/26
Built in BACnet MS/TP
7/27/2019 F700 Version-Up Presentation
21/26
Built in BACnet MS/TP
7/27/2019 F700 Version-Up Presentation
22/26
Energy Savings Easy to ObserveThe effect of energy savings can be confirmed using the operation
panel, output terminal (AM, CA terminal) and via networks with the
newly developed energy saving monitor .
Reminders
7/27/2019 F700 Version-Up Presentation
23/26
PID sleep function
Reminders
Possible to reduce energy consumption in the
low-efficiency, low-speed range. (Sleep function)
Advanced PID function can
control multiple motors (4 motors
maximum).
Possible to control by switchingbetween the inverter-driven
operation and commercial power-
driven operation.
Multiple motors control
7/27/2019 F700 Version-Up Presentation
24/26
NEXT STEPS
Controlled Testing of Flux Optimization
7/27/2019 F700 Version-Up Presentation
25/26
Thank you very muchfor your attention
7/27/2019 F700 Version-Up Presentation