    ESP 8 D PASS READINGS BEFORE TAKING SHUTDOWN

    FIE

    LD

    NO.

    1D1 2D1 3D1 4D1 5D1 6D1 7D1 1D2 2D2 3D2 4D2 5D2 6D2 7D2

    Cur

    rent

    %

    - 31 29 14 23 31 65 45 30 19 20 121 139 52

    E U/V 38 41 40 41 40 38 40 43 61 38 36 37 23

    Ch

    ratio

    11 21 31 41 51 61 7 11 21 31 41 51 61

  • 7/31/2019 Factors Affecting ESP

    5/13

    D PASS FIELDS STILL AIR CHARGING RESULTS

    AT CHARGE RATIO SET AS 1

    FIE

    LD

    NO.

    1D1 2D1 3D1 4D1 5D1 6D1 7D1 1D2 2D2 3D2 4D2 5D2 6D2 7D2

    A 230 180 195 180 80 200 150 175 170 220 130 195 225 175

    V 310 300 310 320 210 ME

    TER

    ERA

    TIC

    210 320 360 350 300 340 360 330

    mA 980 1200 1200 1200 300 1000 350 800 1200 1000 550 1000 575 600

    KV 46 43 44 46 43 48 36 43 46 46 48 42 46 48

  • 7/31/2019 Factors Affecting ESP

    6/13

    ESP 8 D PASS READINGS AFTER SERVICE

    FIE

    LD

    NO.

    1D1 2D1 3D1 4D1 5D1 6D1 7D1 1D2 2D2 3D2 4D2 5D2 6D2 7D2

    Cur

    rent

    %

    80 68 78 74 97 118 66 66 85 123 37 195 123 61

    E 39 34 34 39 38 36 32 43 39 52 38 32 32 30

    Ch

    ratio

    7 11 21 31 41 51 61 7 11 21 31 41 51 61

  • 7/31/2019 Factors Affecting ESP

    7/13

  • 7/31/2019 Factors Affecting ESP

    8/13

  • 7/31/2019 Factors Affecting ESP

    9/13