608 State St. South Kirkland, WA 98033 www.faira.com [email protected] +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue, WA 98004 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/12013 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team
Transcript
Page 1: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

608 State St. South Kirkland, WA 98033

www.faira.com

[email protected] +1.800.571.FAIR

FAIRA TRANSPARENCY REPORTS

10840 NE 35th Pl, #2, Bellevue, WA 98004

Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.

You may view more detailed information for this home and can make an offer at

http://www.faira.com/listings/12013 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Page 2: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc.Property Inspection Report

Cover Page

10840 NE 35th Pl #2, Bellevue, WA 98004Inspection prepared for: Faira .com

Real Estate Agent: Faira .com - Faira

Date of Inspection: 5/1/2018 Time: 9:00 AM Age of Home: 1975 Size: 1337 Weather: Cloudy 50 degrees

Order ID: 3674 Front door faces south for orientation purposes only

Inspector: Dee Robert InmanLicense #1459

Email: [email protected]

Page 3: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 1 of 47

Inspection Details INTRODUCTION: We appreciate the opportunity to conduct this inspection for you!   Please carefully read your entireInspection Report.  Call us after you have reviewed your report, so we can go over any questionsyou may have.  Remember, when the inspection is completed and the report is delivered, we are stillavailable to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail.” -  The following report is based on an inspectionof the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; thisreport will focus on safety and function, not current code. This report identifies specific non-code,non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repairany critical concerns and defects.  Note that this report is a snapshot in time. We recommend thatyou or your representative carry out a final walk-through inspection immediately before closing tocheck the condition of the property, using this report as a guide. Items denote serious, safety or items that required further investigationItems denote minor or maintenance itemsItems denote locations and shutoff valves

1. AttendanceIn Attendance: Seller present

2. Home TypeHome Type: Condominium/Townhouse

3. OccupancyOccupancy:• Vacant• The utilities were on at the time of inspection.

Page 4: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 2 of 47

General Exterior Note 1. Exterior NoteObservations:• South Elevation• East Elevation• West Elevation

||2||West Elevation ||2||South Elevation

||2||East Elevation

Page 5: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 3 of 47

Exterior Areas 1. Siding ConditionSiding appeared in fair condition overall. • Cedar channel back sidingObservations:• Paint flaking at the siding, recommend loose paint is removed, barewood areas primed andrepainted.• Soil contact or proximity. This may provide entrance of moisture or insects to siding.Recommend grading soil so there is at least 6" of space (where practical) between the siding andthe soil below. Recommend checking for any damaged trim and siding materials.• Decay occurring to the siding. Recommend extent of damage is investigated further and repaired.

Decay noted at the base of siding south

Soil in contact with siding2. GuttersGutters and downspouts appeared in good condition overall.Observations:• Debris in gutters, recommend cleaning gutters.

Page 6: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 4 of 47

3. Driveway and Walkway ConditionAsphalt driveways appeared in fair condition overall.

4. SoffitSoffits and eaves appeared in good condition overall.

Page 7: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 5 of 47

5. Door/WindowExterior doors appeared in operable condition, at time of inspection. • Threshold and jambsappeared in good condition overall. • Window frames and sills appeared in good condition overall.

6. GradingGrading appeared in good condition overall.Observations:• Foliage is touching the siding, recommend clearance is achieved as this is a conducive conditionfor wood destroying organisms and pests

Foliage in contact with siding7. ElectricalExterior outlets operate overall • Exterior lights attached to the house operate overall.Observations:• Exterior outlets are not GFI protected. Strongly recommend further investigation and correction bylicensed electrical contractor.

8. Cable FeedsMaterials: Primary Service is Underground Service Lateral

Page 8: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 6 of 47

9. Exterior Faucet ConditionExterior faucets were in operable condition overall.Observations:• Hose bib at south side of house leaks.

10. Pressure135Observations:• Water pressure is in excess of 80 PSI. Water pressure above 80 PSI can result in plumbing leaksand cause plumbing appliances to wear more quickly, recommend adjusting water pressure orinstalling pressure reducing valve.

Page 9: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 7 of 47

Porches 1. Porch1South

2. PorchPorch surface and Visible framing appeared in good condition overall. • Guardrail appeared secure.• Handrail appeared secure.

Page 10: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 8 of 47

Deck 1 1. Deck1South

2. DeckDeck surface is covered with water proof membrane, appeared in good condition overall. •Guardrail appeared secure.Observations:• Guardrail balusters/spindles are spaced further than the maximum 4 inches, this requirement is toprevent small children from fitting through guardrail.

Exceeds 4"

Page 11: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 9 of 47

Exterior Stairs 1. StairHandrail appeared secure.Observations:• Steps were not uniform height, normally there should be no more that a 3/8th inch variancebetween riser heights. Recommend using caution.• Decay noted at top riser. Recommend repairs

Decay noted at top riser

Page 12: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 10 of 47

Roof 1. Roof ConditionArchitectural Composition shingle. • Roof surface is appeared in good condition overall. •Inspected with DroneType Average life span 30 years for this type surface with proper maintenance and care.

2. ChimneyMetal Chimney with wood enclosure

Page 13: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 11 of 47

Page 14: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 12 of 47

Attic 1 1. AtticAttic access is located in bedroom closet

2. FramingVisible framing appeared in good condition overall, no visible indications of decay or waterpenetration presently.

Page 15: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 13 of 47

3. VentilationVentilation appeared adequate overall. • Under eave soffit inlet vents noted. • Roof surface ventspresent. • Continuous Ridge Vent present.

4. Fan/DuctBathroom fans appeared to exhaust to the exterior overall.

5. Insulation ConditionBlown in fiberglass insulation noted. • Unfinished fiberglass batts noted.Depth: Insulation averages about 14-16 inches in depth, estimated R value 38

Page 16: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 14 of 47

6. Rodent/PestsNo visible indications of Rodent Activity.

Page 17: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 15 of 47

General Interior Note 1. General NotesMaterials: Windows in the home are Double pane insulated glass windows. Any deficiencies arenoted in each room section for accessible windows • Doors in the home are considered operationalunless otherwise noted in each room section

Page 18: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 16 of 47

Entryway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. Entry door operates andlocks overall. • Wood flooring is in good condition overall.

Page 19: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 17 of 47

Living Room 1. LocationLocation West

2. Living RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate. • Light fixture operates.

3. Window DeficienciesObservations:• Cracked or broken window glass was observed. Injury could occur. Recommend repair orreplacement of the damaged glass.

Broken window4. FireplaceFireplace is a electric unit.Observations:• Fireplace not installed at the time of inspection. No test was conducted

Page 20: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 18 of 47

Page 21: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 19 of 47

Dining Room 1. Dining RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate.

Page 22: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 20 of 47

Kitchen 1. Kitchen RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate. Light fixture operates. Sink and faucets are in operable conditionoverall. Cabinet doors and drawers are in operable condition overall.

2. Counter ConditionWood butcher block counter is in good condition overall. • Quartzite counter tops are in goodcondition.

3. CabinetCabinet doors and drawers are in operable condition overall.

4. DisposalDisposal operates overall.

5. DishwasherDishwasher was in operable condition.Observations:• Lack of a proper air gap noted at dishwasher drain line. In the event of a sewer backup this deviceprevents sewer matter from entering into dishwasher. Recommend having a licensed plumberinstall a air gap or drip loop to prevent possible contamination to water supply. Minor condition tocorrect

Page 23: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 21 of 47

Dishwasher discharge needs high loop6. MicrowaveObservations:• Built-in microwave ovens are tested using normal operating controls. Unit was tested andappeared to be serviceable at time of inspection. Leak and/or efficiency testing is beyond the scopeof this inspection. If concerned, client should seek further review by qualified technician prior toclosing.

7. Stove/OvenStove/oven were in operable condition overall.

Oven is operational8. RefrigeratorRefrigerator was in operable condition.

Page 24: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 22 of 47

Refrigerator temp Freezer temp9. SinksSink was in operable condition overall.

10. ElectricalObservations:• No GFCI protection at left side of sink present, strongly recommend conditions are investigatedfurther and corrected as required by licensed electrical contractor.

11. Vent ConditionVent fan is part of microwave and is Recirculating Type

Page 25: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 23 of 47

1/2 Bathroom 1. Location1st Floor

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.Toilet was in operable condition overall .

3. CounterEngineered Composite Vanity Top with Basin

4. CabinetCabinet doors and drawers are in operable condition overall.

5. SinksSink was in operable condition overall.

6. ElectricalObservations:• No GFCI protection present, Strongly recommend installing GFCI protected receptacles forsafety.

7. Exhaust FansVent fan operates overall.

8. FloorsIndividual vinyl square Flooring is in good condition overall.

9. ToiletToilet was in operable condition overall.

Page 26: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 24 of 47

Stairs Leading to 2nd Floor 1. StairSteps appeared uniform.Observations:• There is no handrail present, normally there should be a handrail when there are 4 or more stairsas a safety precaution.

Page 27: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 25 of 47

Upstairs Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. • Carpet floor covering is ingood condition. • Accessible outlets operate.

Page 28: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 26 of 47

Upstairs Laundry 1. LocationHall bathroom

2. ConditionCeiling and walls are in good condition overall. Accessible outlets operate. • Light fixture operates.

3. DryerDryer is electric Unit • 220 volt electrical service for electric dryer.

4. WasherMaterials: Washer appeared to be in operable condition.Observations:• Washer and dryer connections were not visible. No inspection was conducted

Page 29: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 27 of 47

Master Bedroom 1. LocationLocation West

2. BedroomWalls and ceilings appear in good condition overall. Flooring is carpet in good condition. Heatregister present. Accessible outlets operate.

3. ElectricalMaterials: Top halves of outlet on the east wall switch controlled.

4. HeatingHeat register operates.

Page 30: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 28 of 47

Master Bathroom 1. LocationMaterials: Bedroom

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

3. ElectricalObservations:• Outlets are not GFCI protected. Strongly recommend conditions are investigated further andcorrected by licensed electrical contractor as a safety precaution.

4. CountersPorcelain counter tops are in good condition.

5. CabinetsCabinet doors and drawers are in operable condition overall.

6. SinksSink was in operable condition overall.

7. Exhaust FansVent fan operates overall.

8. FloorsLaminate wood grain material is in good condition overall.

9. ShowerShower is in good condition overall.

10. ToiletToilet was in operable condition overall.

11. HeatingHeat register operates.

Page 31: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 29 of 47

Hall Bathroom1 1. LocationMaterials: Upstairs

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

3. ElectricalObservations:• GFCI did not trip with tester GFCI trip test, strongly recommend conditions are investigated furtherand corrected by licensed electrical contractor as a safety precaution.

4. CountersPorcelain counter tops are in good condition.

5. CabinetsCabinet doors and drawers are in operable condition overall.

6. Exhaust FansVent fan operates overall.

Page 32: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 30 of 47

7. FloorsLaminate wood grain material is in good condition overall.

8. TubTub and shower were in good condition overall.

9. SinksSink was in operable condition overall.

10. ToiletToilet was in operable condition overall.Observations:• Toilet is not caulked to the floor: Toilets caulked at the floor are less likely to have leaking waxseals. Caulking reduces the potential for movement, limiting forces on the seal which mightcause it to leak

11. HeatingHeat register operates.

Page 33: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 31 of 47

Bedroom 1 1. LocationLocation 1st Right

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate.

3. ElectricalObservations:• No light fixture or switched outlet in place

4. DoorsObservations:• Entry door does not catch, minor adjustment to strike plate may remedy this condition.• Guides missing at the base of closet door.

Page 34: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 32 of 47

Bedroom 2 1. LocationLocation Southwest

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate.

3. ElectricalObservations:• No light fixture or switched outlet in place

4. HeatingHeat register operates.

5. DoorsObservations:• Guides missing at the base of closet door.

Page 35: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 33 of 47

Storage Room 1. Storage RoomWalls and ceilings appear in good condition overall.

Page 36: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 34 of 47

Garage 1. ConditionWalls and ceilings appeared in good condition overall. Accessible outlets operate. Light fixturesoperate overall. Flooring is concrete, visible portions in good condition overall.

2. Floor ConditionMaterials: Flooring is concrete, appeared in good condition overall.Observations:• Cracking at the floor does not appear unusual.

3. Garage DoorsSingle garage door operates, was on auto opener. • Photo cell safety returns operate overall. •Tension safety returns operate overall. • Manual garage door operates and locks.

Page 37: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 35 of 47

Heat/AC 1. Heating TypeElectric forced air furnace. there was good air flow at the heat registers and cold air return overall.

2. Heater Location The furnace is located in the atticFurnace is Wesco Brand.Observations:• Age of furnace was indeterminate, recommend consulting with licensed heating contractor.• The heating unit is approaching its designed life expectancy. We make no warranty, guarantee orestimation as to the remaining useful life of this unit.

3. Heating conditionObservations:• Service does not appear to have been performed within the last year, recommend serviced bylicensed HVAC contractor.

All registers tested and have heat

4. FiltersLocation: Left side of furnace filter location

Page 38: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 36 of 47

Page 39: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 37 of 47

Plumbing/Water Heater1 1. PlumbingWater lines were copper • Drain and waste lines were plastic.

2. Water Heater ConditionHeater Type: Electric water heater. • 50 gallonsLocation: The heater is located in the hall closet.Observations:• Water heater temperature is in excess of 120 degrees, recommend adjustment to preventaccidental scalding.

Water temp at kitchen sink3. AgeObservations:• Water heater is near end of useful life span, recommend monitoring.• Approximately 12 years of age, average life span is 10 to 12 years.

4. ConditionObservations:• Seismic straps are not in place/ improperly installed. Normally there should be seismic strapsinstalled at the upper and lower one thirds of the tank.• Expansion tank is not in place. This is a hazardous condition on closed water systems.Recommend conditions are investigated further and corrected as required by licensed plumbingcontractor.• Drip pan does not have outlet drain to exterior, recommend outlet drain be installed or leak alarmsensor

5. TPRV ConditionTemperature Pressure Relief Valve (TPR Valve) present.Observations:• Temperature and pressure relief valve routes at an upward angle. This condition can cause waterto set in the outlet drain resulting in corrosion to the temperature and pressure relief valve andcause it not to engage when needed. This is an extremely hazardous condition, stronglyrecommend conditions are corrected by licensed HVAC contractor.

Page 40: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 38 of 47

Routes at an upward angle

Page 41: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 39 of 47

Electrical 1 1. LocationMaterials: Located in the Garage

2. Electrical200 AMP service, 4/0 Aluminum service entrance wires.

3. GroundingElectrical service is grounded and bonded.

4. Wiring TypeBreaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiringis copper.

Page 42: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 40 of 47

Foundation/Crawlspaces 1. LocationGarage

2. FoundationContinuous concrete foundation visible portion appeared in good condition overall.

3. DrainageCrawlspace area was dry, there were no visible indications of standing water presently

4. FramingVisible framing appeared in good condition overall.

5. VentilationObservations:• Inadequate ventilation. Normally there should be 1 square foot of venting for each 150 square feetof crawlspace surface area placed so that cross ventilation is achieved. Inadequate ventilation is aconducive condition for wood decay and mold growth, recommend conditions are corrected

Page 43: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 41 of 47

6. Insulation ConditionEncapsulated fiberglass batts noted.Depth: Insulation averages 2 inches, estimated R value 7. Newer requirements are R30 Insulationcontent.Observations:• Insulation damaged/missing in areas of the crawlspace, recommend conditions are corrected.

7. Vapor BarrierObservations:• Clear plastic vapor barrier, newer requirements are 6 mil black plastic vapor barrier.

8. RodentNo visible indications of Rodent Activity.

Page 44: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 42 of 47

Shutoffs 1. Shutoff LocationsObservations:• Water heater water line shutoff is located to the left of the water heater.• Main water shutoff is located in the entry closet• Furnace disconnect is located at the front panel of the furnace.• Furnace disconnect is located at the west wall to the left of the furnace.

||2||Water heater water line shutoff is located tothe left of the water heater.

||2||Main water shutoff is located in the entrycloset

Furnace disconnect is located at the front panel of the furnace.

Page 45: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 43 of 47

Equipment 1. Appliances/Equipment

||2||Microwave ||2||Stove

||2||Refrigerator ||2||Dishwasher

Page 46: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 44 of 47

||2||Disposal ||2||Water Heater

||2||Dryer ||2||Washer

||2||Furnace

Page 47: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 45 of 47

GlossaryGlossary

Term DefinitionAir Gap Air gap (drainage): The unobstructed vertical distance through

free atmosphere between the outlet of the waste pipe and theflood-level rim of the receptacle into which the waste pipe isdischarged.

Expansion Tank An expansion tank or expansion vessel is a small tank used toprotect closed (not open to atmospheric pressure) water heatingsystems and domestic hot water systems from excessivepressure. The tank is partially filled with air, whosecompressibility cushions shock caused by water hammer andabsorbs excess water pressure caused by thermal expansion.

GFCI A special device that is intended for the protection of personnelby de-energizing a circuit, capable of opening the circuit wheneven a small amount of current is flowing through the groundingsystem.

TPR Valve The thermostat in a water heater shuts off the heating sourcewhen the set temperature is reached. If the thermostat fails, thewater heater could have a continuous rise in temperature andpressure (from expansion of the water). The temperature andpressure could continue to rise until the pressure exceeds thepressure capacity of the tank (300 psi). If this should happen, thesuper-heated water would boil and expand with explosive force,and the tank would burst. The super-heated water turns to steamand turns the water heater into an unguided missile. To preventthese catastrophic failures, water heaters are required to beprotected for both excess temperature and pressure. Usually, themeans of protection is a combination temperature- and pressure-relief valve (variously abbreviated as T&P, TPV, TPR, etc.). Mostof these devices are set to operate at a water temperature above200° F and/or a pressure above 150 psi. Do not attempt to testthe TPR valve yourself! Most water heating systems should beserviced once a year as a part of an annual preventivemaintenance inspection by a professional heating and coolingcontractor. From Plumbing: Water Heater TPR Valves

Page 48: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 46 of 47

Report SummaryReport Summary

The summary below consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expense to correct or items I would like to draw extra attentionto. The summary is not a complete listing of all the findings in the report, and reflects the opinion ofthe inspector. Please review all pages of the report as the summary alone does not explain all of theissues. All repairs should be done by a licensed & bonded tradesman or qualified professional. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.Exterior AreasPage 3 Item: 1 Siding Condition • Decay occurring to the siding. Recommend extent of

damage is investigated further and repaired.Page 5 Item: 7 Electrical • Exterior outlets are not GFI protected. Strongly recommend

further investigation and correction by licensed electricalcontractor.

Page 6 Item: 10 Pressure • Water pressure is in excess of 80 PSI. Water pressureabove 80 PSI can result in plumbing leaks and causeplumbing appliances to wear more quickly, recommendadjusting water pressure or installing pressure reducing valve.

Deck 1Page 8 Item: 2 Deck • Guardrail balusters/spindles are spaced further than the

maximum 4 inches, this requirement is to prevent smallchildren from fitting through guardrail.

Exterior StairsPage 9 Item: 1 Stair • Steps were not uniform height, normally there should be no

more that a 3/8th inch variance between riser heights.Recommend using caution.• Decay noted at top riser. Recommend repairs

Living RoomPage 17 Item: 3 Window

Deficiencies• Cracked or broken window glass was observed. Injury couldoccur. Recommend repair or replacement of the damagedglass.

KitchenPage 22 Item: 10 Electrical • No GFCI protection at left side of sink present, strongly

recommend conditions are investigated further and correctedas required by licensed electrical contractor.

1/2 BathroomPage 23 Item: 6 Electrical • No GFCI protection present, Strongly recommend installing

GFCI protected receptacles for safety.Stairs Leading to 2nd FloorPage 24 Item: 1 Stair • There is no handrail present, normally there should be a

handrail when there are 4 or more stairs as a safetyprecaution.

Upstairs LaundryPage 26 Item: 4 Washer • Washer and dryer connections were not visible. No

inspection was conductedMaster BathroomPage 28 Item: 3 Electrical • Outlets are not GFCI protected. Strongly recommend

conditions are investigated further and corrected by licensedelectrical contractor as a safety precaution.

Page 49: FAIRA TRANSPARENCY REPORTS 10840 NE 35th Pl, #2, Bellevue ... · RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA Page 5 of 47 5. Door/Window Exterior doors appeared in

RW West Consultants, Inc. 10840 NE 35th Pl #2, Bellevue, WA

Page 47 of 47

Hall Bathroom1Page 29 Item: 3 Electrical • GFCI did not trip with tester GFCI trip test, strongly

recommend conditions are investigated further and correctedby licensed electrical contractor as a safety precaution.

Bedroom 1Page 31 Item: 3 Electrical • No light fixture or switched outlet in placeBedroom 2Page 32 Item: 3 Electrical • No light fixture or switched outlet in placeHeat/ACPage 35 Item: 2 Heater • Age of furnace was indeterminate, recommend consulting

with licensed heating contractor.• The heating unit is approaching its designed life expectancy.We make no warranty, guarantee or estimation as to theremaining useful life of this unit.

Plumbing/Water Heater1Page 37 Item: 2 Water Heater

Condition• Water heater temperature is in excess of 120 degrees,recommend adjustment to prevent accidental scalding.

Page 37 Item: 4 Condition • Seismic straps are not in place/ improperly installed.Normally there should be seismic straps installed at the upperand lower one thirds of the tank.• Expansion tank is not in place. This is a hazardous conditionon closed water systems. Recommend conditions areinvestigated further and corrected as required by licensedplumbing contractor.• Drip pan does not have outlet drain to exterior, recommendoutlet drain be installed or leak alarm sensor

Page 37 Item: 5 TPRV Condition • Temperature and pressure relief valve routes at an upwardangle. This condition can cause water to set in the outlet drainresulting in corrosion to the temperature and pressure reliefvalve and cause it not to engage when needed. This is anextremely hazardous condition, strongly recommendconditions are corrected by licensed HVAC contractor.

Foundation/CrawlspacesPage 40 Item: 5 Ventilation • Inadequate ventilation. Normally there should be 1 square

foot of venting for each 150 square feet of crawlspace surfacearea placed so that cross ventilation is achieved. Inadequateventilation is a conducive condition for wood decay and moldgrowth, recommend conditions are corrected